Aviat Networks MDR5800ET Point to Point Spread Spectrum Transceiver User Manual Manual

Aviat Networks Point to Point Spread Spectrum Transceiver Manual

Manual

Download: Aviat Networks MDR5800ET Point to Point Spread Spectrum Transceiver User Manual Manual
Mirror Download [FCC.gov]Aviat Networks MDR5800ET Point to Point Spread Spectrum Transceiver User Manual Manual
Document ID149925
Application IDzNxsGrA1LovGVBPlaoMTXQ==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize199.11kB (2488862 bits)
Date Submitted2001-05-15 00:00:00
Date Available2001-05-15 00:00:00
Creation Date0000-00-00 00:00:00
Producing SoftwareAcrobat PDFWriter 3.0 for Windows
Document Lastmod2001-04-28 05:29:48
Document TitleManual
Document CreatorMicrosoft Word

MDR5800 User Manual
MDR5800 Digital Radio
User Manual
Document Number: 862-01881
862-01881 Issue 6
Page 1
MDR5800 User Manual
Issue Status
Issue
Revised Pages/Amendments
31
General – terminology definition PER used instead of BER to
remove interpretation ambiguity between Block Error Rate and Bit
Error Rate. Note Block (equivalent to packet) concept is still
maintained within sections describing G.826 parameters to maintain
consistency with G.826 terminology.
MIB Description chapter added, RESET Button Additions, chapter on
setup of a serial connection between a PC/Laptop and the Element
Management Port, IP network address description diagrams.
Amendments related to customer furnished equipment, Outdoor Unit
temperature range update, Maintenance and Ordering section
updates, Appendix added regarding Antennas.
FEDERAL COMMUNICATIONS COMMISSION NOTICE
The equipment has been tested and found to comply with the limits for a Class A digital devices,
pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
The manufacturer is not responsible for any radio or TV interference caused by unauthorized
modifications to this equipment. Such modifications could void the user's authority to operate the
equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
WARNING- To comply with FCC RF exposure limits, the
antennas for this transmitter must be fix-mounted to
provide a separation distance of 2 meters (6.6 ft) or more
from all persons to satisfy RF exposure requirements.
This equipment must be professionally installed.
The antennas for this equipment must be fixed mounted on permanent outdoor structures.
862-01881 Issue 6
Page 2
MDR5800 User Manual
Publication Number: 862-01881
Issue 6
April 2001
© 1999 Tellumat (Pty) Limited
The information contained herein is the property of Tellumat (Pty) Limited and is supplied
without liability for errors or omissions. No part may be reproduced, used or disclosed
except as authorised by contract or other written permission. The copyright and the
foregoing restriction on reproduction, use and disclosure extend to all media in which this
information may be embodied, including magnetic or electronic storage etc.
862-01881 Issue 6
Page 3
MDR5800 User Manual
Table of Contents
Page
INTRODUCTION
1.1
MDR5800 Description
TECHNICAL DESCRIPTION
11
2.1
System Overview
11
2.2
Outdoor Unit
11
2.2.1
Frequency plans
12
2.2.2
RF Power Output Options
13
2.2.3
MDR5800 Outdoor Unit
13
2.3
Indoor Unit
14
2.3.1
Payload Interface Options
14
2.3.2
Service (Wayside) Serial Data Channel
16
2.3.3
Element Manager Port
16
2.3.4
10BaseT Ethernet RJ45 Port
16
2.3.5
IU/OU Link LED
17
2.3.6
IU/OU Data Interconnect RJ45
17
2.3.7
IU/OU Power Interconnect
17
2.3.8
Auxiliary In/Out Port
17
2.3.9
DC Power Input
18
2.3.10
Fuse Holder
18
2.3.11
ON/OFF Switch
18
2.3.12
Ground Terminal
18
PLANNING
20
3.1
System Type Selection
20
3.1.1
Antenna selection (MDR5800)
20
3.2
Site Evaluation
21
3.3
Multipath Effects
21
3.4
Interference Considerations
22
3.5
Microcell Backhaul Applications of MDR5800 Digital Radios
23
3.5.1
Setting the Transmitted Power Levels
862-01881 Issue 6
23
Page 4
MDR5800 User Manual
3.5.2
Frequency Multiplexing
23
3.5.3
Antenna Isolation
23
INSTALLATION
25
4.1
Customer Furnished Tools and Equipment
26
4.2
Indoor Unit
27
4.2.1
Introduction
27
4.2.2
Installing the Indoor Unit in a Rack
27
4.2.3
Connecting a DC Power Supply
28
4.2.4
Balanced Payload Data
29
4.2.5
Connecting Auxiliary In/Out (Optional)
30
4.2.6
Connecting the Service (Wayside) Serial Channel (Optional)
31
4.2.7
Connecting the Element Manager Port
31
4.3
4.3.1
4.4
4.4.1
Outdoor Unit
MDR5800 Outdoor Unit
Interconnection Cable Installation
INTERCONNECTION CABLE WIRING DESCRIPTION
32
32
33
34
ANTENNA ALIGNMENT AND SOFTWARE SETUP
36
5.1
Installation Equipment Required
36
5.2
Information Required
36
5.3
Antenna Alignment
36
5.3.1
Introduction
36
5.3.2
Alignment Procedure
37
5.3.3
Set Transmitted Power Level
37
5.4
Software Setup
38
5.5
Functional Test
38
5.5.1
Link Bit Error Rate Performance Test
38
5.6
MDR5800 Installation Record
40
5.7
MDR5800 Test Record
41
NMS SOFTWARE
43
6.1
Introduction to the Network Management System
43
6.2
General Information
43
6.2.1
Microwave Digital Radio
862-01881 Issue 6
44
Page 5
MDR5800 User Manual
6.3
6.3.1
6.4
Main Screen
Link Elements Areas
NMS Menus
45
46
47
6.4.1
Main Screen Menus
47
6.4.2
Main Screen Short-cut Buttons
49
6.5
Indoor Unit Configuration
49
6.5.1
Controls
49
6.5.2
Menu Items
52
6.6
Outdoor Unit Configuration
56
6.6.1
Controls
56
6.6.2
Menu Items
56
6.6.3
OU Station Info
57
6.6.4
Outdoor Unit Status
57
6.7
RF Link Error Status Monitoring
58
6.7.1
RF Link Status
58
6.7.2
Packet Error Rate Thresholds
58
6.7.3
RF Link Error Monitor
59
MAINTENANCE INFORMATION
62
TECHNICAL DATA
64
8.1
Environmental Requirements
64
8.1.1
Outdoor Equipment
64
8.1.2
Indoor Equipment
64
8.2
8.2.1
Mechanical Information for Outdoor Equipment
MDR5800 Outdoor Unit
64
64
8.3
Mechanical Information for Indoor Equipment
64
8.4
Power Supply Requirements
64
8.5
Electrical Performance
64
8.5.1
General Characteristics
65
8.5.2
Transceiver Characteristics
65
8.5.3
RF Interface
66
8.5.4
Payload Data Interfaces
66
8.5.5
Auxiliary Input Interface (CONTACT CLOSURE)
67
8.5.6
Auxiliary Output Interface
67
862-01881 Issue 6
Page 6
MDR5800 User Manual
8.5.7
Wayside channel interface
67
8.5.8
Element Manager Port Interface
67
8.5.9
Indoor/Outdoor Unit Interface
67
8.6
Ordering Information
APPENDIX A: ELEMENT MANAGER PORT POINT-TO-POINT SERIAL COMMUNICATIONS SETUP72
9.1
Adding a Modem : Windows NT
73
9.2
Adding Dial-up Networking : Windows NT
77
9.2.1
To add dial-up networking
69
77
9.3
Adding a Modem : Windows 95/98
82
9.4
Adding Dial-up Networking : Windows 95/98
85
10
APPENDIX B: MANAGEMENT OF THE MDR5800
87
10.1
SNMP and the MDR5800
87
10.2
The MIB Elements – OID (Object ID) DESCRIPTIONS
89
10.3
The MIB elements – TRAP DESCRIPTIONS
102
11
APPENDIX C: SETUP OF A PC (WIN 95, 98, NT) TO ALLOW PINGING OF A ‘REMOTE’-CONFIGURED
INDOOR UNIT
105
11.1
IP CONFIGURATION OF THE MDR5800 – ROUTING CONFIGURATION
11.2 IP CONFIGURATION OF THE MDR5800 – BRIDGING AND ROUTING
CONFIGURATION
105
107
12
APPENDIX D: MDR5800 HARDWARE VERSION 1, 2.X DIFFERENCES, COMPATIBILITY SUMMARY
108
13
APPENDIX E: FIXED ANTENNAS
862-01881 Issue 6
109
Page 7
MDR5800 User Manual
List of Abbreviations
BIT
Built-in-Test
AIS
Alarm Indication Signal
PER
Packet (or Block) Error Rate
DC
Direct Current
DCE
Data Communications Equipment
DRL
Digital Radio Link
DRS
Digital Radio Station
DTE
Data Terminal Equipment
IU
Indoor Unit
ISM
Industrial, Scientific and Medical
LED
Light Emitting Diode
LOS
Loss of signal
Mbps
Megabits per second
N.C
Normally-closed
N.O
Normally-open
NMS
Network Management System
OU
Outdoor Unit
PC
Personal Computer
RF
Radio Frequency
RSSI
Received Signal Strength Indication
SNMP
Simple Network Management Protocol
862-01881 Issue 6
Page 8
MDR5800 User Manual
1 INTRODUCTION
1.1
MDR5800 Description
The MDR5800 is a 5.8 GHz digital radio system that provides short to medium range,
point-to-point digital communication with high data security at rates of E1, 2E1 or 4E1.
Alternatively, the radio can be software configured to convey T1, 2T1 or 4T1. The
radio can also be configured to bridge or route IP via a 10BaseT Ethernet port. The
data rates scale depending on the number of enabled E1/T1 tributaries and whether
the data is being bridged or routed. The product makes use of spread spectrum
technology and may be operated license-free in the 5.8 GHz ISM band. It is ideal for
applications such as:
•
Telecommunications companies, cellular operators and private carriers.
•
Cellular/PCS base station interconnects.
•
Internet distribution.
•
Video surveillance data distribution.
•
Rural communications.
The MDR5800 consists of two main parts:
•
An Outdoor Unit operating in the 5.8 GHz ISM frequency band.
•
An Indoor Unit, available with a Telecommunications (1, 2 or 4E1 or 1, 2 or
4T1) interface and a Data interface (10BaseT Ethernet).
Interconnection between the Outdoor Unit and Indoor Unit is achieved using a lowcost UV-protected STP (Screened Twisted Pair: 4 pairs) data cable and a UVprotected 2-core power cable. The MDR5800 series product uses a split Indoor Unit
and Outdoor Unit configuration for lowest loss between the antenna and the
transceiver, thereby ensuring optimal long-range performance.
MDR5800 Outdoor Unit uses a Type-N RF (female) output connector for connection
to any 5.8 GHz antenna for applications where long range is required.
The system is available for use in FCC regulated countries.
862-01881 Issue 6
Page 9
MDR5800 User Manual
Table 1 lists the MDR5800 model variants.
Table 1. MDR5800 model variants
Model Number
Interfaces
Antenna Coupling
Antenna Type
MDR5800-ET1
E1/T1
N-type Female
Customer
supplied
N-type Female
Customer
supplied
N-type Female
Customer
supplied
10BaseT Ethernet
MDR5800-ET2
2 x E1 / 2 x T1
10BaseT Ethernet
MDR5800-ET4
4 x E1 / 4 x T1
10BaseT Ethernet
Refer to section 8 for Ordering details.
The Network Management System provides control and management of the product.
SNMP support via an SNMP agent in the Indoor Unit ensures open network
management compatibility.
Comprehensive data and RF loop-back functions ensure that the system is easy to
install and maintain.
862-01881 Issue 6
Page 10
MDR5800 User Manual
2 TECHNICAL DESCRIPTION
2.1
System Overview
A MDR5800 digital radio link (DRL) consists of a pair of MDR5800 radio stations.
MDR5800 ODU
MDR5800 IDU
User Data
MDR5800 ODU
MDR5800 IDU
User Data
The MDR5800 radio station consists of two main parts:
•
An Outdoor Unit operating in the 5.8 GHz ISM frequency band. The Outdoor Unit
provides the radio transceiver functionality by accepting radio link data from the
Indoor Unit and converting it to the 5.8 GHz ISM frequency band using spread
spectrum modulation. The received signal is de-spread and transmitted to the
Indoor Unit in a digital format.
•
An Indoor unit, available with 1, 2 or 4 E1 and 1, 2 or 4 T1 data interfaces (choice
of E1 or T1 is software selectable). The Indoor Unit combines nE1 or nT1 data
with Wayside Service Channel serial data and link IP data to be transmitted
across the radio link. The Indoor Unit also provides power to the Outdoor Unit.
Interconnection between Outdoor Unit and Indoor Unit is achieved using low cost data
and power cables.
2.2
Outdoor Unit
The MDR5800 Outdoor Unit makes use of Spread Spectrum modulation technology
for license-free operation in the 5.8 GHz ISM band.
For MDR5800 operation, the 5.8 GHz ISM band is divided into upper and lower
frequency sub-bands. An MDR5800 ‘High Band’ Outdoor Unit transmits in the higher
frequency sub-band and receives in the lower frequency sub-band, while a ‘Low Band’
Outdoor Unit transmits in the lower sub-band and receives in the higher sub-band. An
MDR5800 radio link will use a ‘Low Band’ Outdoor Unit on one end of the link to
communicate with a ‘High Band’ Outdoor Unit on the other end.
The MDR5800 Outdoor Unit uses a Type-N RF output connector for connection to any
5.8 GHz antenna for applications where long range is required.
The system is available for use in FCC regulated countries.
862-01881 Issue 6
Page 11
MDR5800 User Manual
2.2.1
Frequency plans
The MDR5800 Outdoor Units operate in the 5.725 GHz to 5.850 GHz ISM frequency
band. The MDR5800 has predefined frequency channel plans (termed A, B, C and
D).
2.2.1.1
Frequency Channel Plan A, B and C
Transmit-to-receive channel spacing for frequency channel plans A, B and C is 69
MHz. The channel spacing is based on the bandwidth occupied by the spread
spectrum signal (approximately 17 MHz) and is used to optimise link performance. In
the case of plan A, plan B and C, note that both Outdoor Units of a link must be set up
to the same frequency channel plan (i.e. A, B or C).
LOW BAND TRANSMIT
HIGH BAND TRANSMIT
AL
BL
CL
CH
BH
AH
5735
5753
5771
5804
5822
5840
Frequency (MHz)
Figure 1. Frequency channel plans A, B and C
862-01881 Issue 6
Page 12
MDR5800 User Manual
Frequency Channel Plan D
Frequency plan D allows independent control of transmit and receive frequencies.
This enables a very flexible frequency plan and can be used to overcome interference
in the 5.8 GHz ISM band.
The frequencies that can be used in the lower or upper sub-bands can be selected in
1 MHz increments. Performance degradation can be expected when operating using
channel plan D mode and the chosen frequencies are close to the sub-band edges i.e.
a choice of one of the high frequencies in the lower sub-band and one of the lower
frequencies in the upper sub-band.
The allocation of Channel plan D frequencies is shown in Table 2.
Table 2. Channel plan D channel frequencies
2.2.2
Sub-band
Center Frequency (MHz)
5735-5771
5804-5840
RF Power Output Options
The Outdoor Unit is designed for use in countries that have adopted FCC standards.
It is possible to adjust the output power on the OU using the supplied NMS software or
a SNMP Management application.
2.2.3
MDR5800 Outdoor Unit
The MDR5800 Outdoor Unit transmits and receives RF through a diplexer interfaced
via an RF cable to an external antenna. The unit has a type-N connector for
connection to the RF cable used between the OU and the antenna.
The MDR5800 Outdoor Unit houses the following main parts:
•
Transmit/Receive Modules
•
Baseband Modulator/Demodulator Circuitry
•
Microcontroller/Framing & Buffering Circuitry
•
Power Amplifier
•
Diplexer
862-01881 Issue 6
Page 13
MDR5800 User Manual
2.3
Indoor Unit
The Indoor Unit is designed for mounting in a 19” rack, occupying a 1U slot, or can be
table-top standing.
The Indoor Unit accepts user nE1/nT1 and combines it with Wayside Service Serial
Data and IP data to be transmitted across the radio link.
The Indoor Unit is fitted with a DC power supply.
2.3.1
Payload Interface Options
The Indoor Unit can be configured for nE1 or nT1 operation.
•
1, 2 or 4 x E1 (2.048 Mbps)
•
1, 2 or 4 x E1 (1.544 Mbps)
For E1 connectivity, bipolar AMI or HDB3 line coding is software selectable.
For T1 connectivity, bipolar AMI or B8ZS line coding is software selectable.
Element
Manager
Connector
Reset/Configuration
Button
System
LED
nE1/nT1
Connector
RF Link
LED
Payload
LED
10BaseT RJ45
Socket
Figure 2. Indoor Unit Front Panel
Ethernet Link LED
The Indoor Unit LED functionality is described as follows:
Wayside Service
Serial Channel
SYSTEM
Green OK, Orange (OU/IU Comms Error), Red (OU/IU Comms Down)
PAYLOAD
Green OK, Orange (AIS Detected), Red (LOS Detected)
RF LINK
Green OK, Orange (FEC Correcting Errors), Red (FEC unable to correct errors)
862-01881 Issue 6
Page 14
MDR5800 User Manual
In ALL cases flashing red and orange LEDs imply historic alarm conditions
(The alarm can be cleared using the front panel button ‘position 1’ : see
next section).
Reset/Configuration Button
The Front Panel Button has the following functionality used to setup a radio (as
determined by different LEDs lighting up. ‘Position 1’ being RF Link LED (Green), 2
being Payload LED (Green), 3 being System LED (Green), 4 being RF Link LED
(Orange), 5 being Payload LED (Orange) and 6 being System LED (Orange) etc.
1. Clear Front Panel LEDs (and associated alarms in IU)
2. Clear Event Log in the Indoor Unit
3. Reset the Indoor Unit (don’t reset the non-volatile memory’s store of the IU’s
configuration parameters)
4. Routed Configuration: Reset the IU configuration parameters that are stored in nonvolatile memory (BATTERY-BACKED STATIC RAM) and configure as a ‘Far Side
IU’ : i.e. for a ROUTED IP configuration, set the Ethernet IP address as 10.11.1.2,
Element Manager IP address to 10.12.1.2
5. Routed Configuration: Reset the IU configuration parameters that are stored in nonvolatile memory and configure as a ‘Near Side IU’ : i.e. for a ROUTED IP
configuration set the Ethernet IP address as 10.2.1.2, Element Manager IP address
to 10.13.1.2
6. Routed Configuration: If you are not sure how the IU is configured (NEAR or FAR
side IU), reset it AS IS i.e. reset the ‘Near Side IU’ or ‘Far Side IU’ configuration
parameters depending on how the IU is currently configured.
7. Bridged Configuration: Reset the IU configuration parameters that are stored in
non-volatile memory (BATTERY-BACKED STATIC RAM) and configure as a ‘Far
Side IU’ . For a BRIDGED IP configuration, see Appendix C of this document for a
description of the default IP addresses.
8. Bridged Configuration: Reset the IU configuration parameters that are stored in
non-volatile memory and configure as a ‘Near Side IU’. For a BRIDGED IP
configuration, see Appendix C of this document for a description of the default IP
addresses.
862-01881 Issue 6
Page 15
MDR5800 User Manual
NOTE
POSITIONS 4, 5, 6, 7 and 8 RESET THE INDOOR UNIT TO FACTORY DEFAULTS –THESE
RESETS ARE TYPICALLY ONLY USED ONCE (THESE CHOICES RESET CERTAIN
ADJUSTABLE PARAMETERS IN NON-VOLATILE MEMORY IN THE INDOOR UNITS). IF
CHANGES ARE MADE TO THE CONFIGURATION PARAMETERS AND THE USER DOES NOT
WANT THESE TO CHANGE WHEN A UNIT IS RESET, THE INDOOR UNIT CAN BE POWERCYCLED OR POSITION ‘3’ MUST BE USED E.G. THIS TECHNIQUE IS USED IF THE IP
ADDRESSES ASSOCIATED WITH THE NETWORK INTERFACES ARE ADJUSTED – THE
PROCESSOR NEEDS TO BE RESET TO ALLOW THE CHANGE/S TO BE IMPLEMENTED.
IF YOU OVER-RUN THE SELECTION YOU REQUIRE, CONTINUE UNTIL THE LEDs GO
BLANK –THEN, START AGAIN (OPTION AVAILABLE WITH RELEASE 2 OF IU FIRMWARE).
2.3.2
Service (Wayside) Serial Data Channel
This port supports asynchronous full duplex, serial data transfer at a speed of 115200
bps.
The interface type is RS-232 configured as DCE (Data Communications Equipment).
Handshaking can be None, Hardware.
2.3.3
Element Manager Port
This port is used for communication with the NMS software or with an SNMP manager
to control the MDR5800 system. The port must be connected to a serial port
(configured for a speed of 115200 bps) on a personal computer to use the NMS
software.
The interface type is RS-232 configured as DTE (Data Terminal Equipment).
Hardware handshaking is used.
2.3.4
10BaseT Ethernet RJ45 Port
This port is used for communication with the NMS software or with an SNMP manager
to control the MDR5800 system.
The interface type is DTE (Data Terminal Equipment).
862-01881 Issue 6
Page 16
MDR5800 User Manual
IU/OU Power
Interconnect
DC In
IU/OU Data
Interconnect RJ45
IU/OU Link LED
Auxiliary IO
ON/OFF
Switch
Fuse
Holder
Ground
Terminal
Figure 3. Indoor Unit Rear Panel
2.3.5
IU/OU Link LED
This LED indicates if there is a suitable electrical connection between the Indoor and
Outdoor Units1.
2.3.6
IU/OU Data Interconnect RJ45
This receptacle accepts an RJ45 plug that connects to UV-protected STP (Screened
twisted pair) cable used between the IU and the OU.
2.3.7
IU/OU Power Interconnect
This connector (socket) is used for power interconnection between the IU and the OU.
The connection is made using UV-protected 2-core cable. The cable is connected to
a GREEN connector, a plug. The polarity sense (labelled) must be maintained
between the IU and the OU.
2.3.8
Auxiliary In/Out Port
The auxiliary in/out port is used for remote monitoring and control. The following are
provided
•
Two inputs (for sensing contact closure or opening) are provided to sense site
alarm inputs. The states of these alarm inputs can be monitored with NMS, as
well as from an SNMP Management Station.
•
Two relay contact outputs, normally-open and normally-closed contacts, are
provided as alarm / auxiliary outputs. Output states are software customised
Note that only the Ethernet Physical interface is checked on V1 hardware with this LED, not the
RS232/485 interface. The integrity of the RS232/485 interface is checked using the front panel
“System LED”.
862-01881 Issue 6
Page 17
MDR5800 User Manual
and controlled. The outputs are used to indicate alarm or other states selected
by the operator via the NMS or a SNMP Management Station.
2.3.9
DC Power Input
This connector (socket) is used for power input to the IU. The connection is made
using 2-core cable. The cable is connected to a GREY connector, a plug. The
polarity-sense (labelled) must be observed and implemented.
2.3.10 Fuse Holder
This holder is used to hold a fuse (5A).
2.3.11 ON/OFF Switch
This switch is used to control power input to the Indoor Unit (and indirectly the
Outdoor Unit).
2.3.12 Ground Terminal
This is used to accept connection to an earth strap, terminated with a crimped earth
lug. Refer to the installation chapter for details on wire/earth lug requirements.
862-01881 Issue 6
Page 18
MDR5800 User Manual
This page is left blank intentionally.
862-01881 Issue 6
Page 19
MDR5800 User Manual
3 PLANNING
This chapter is aimed at management and planning staff to enable them to assess the
requirements for installing an MDR5800 digital radio link.
3.1
System Type Selection
The MDR5800 system uses an Outdoor Unit with a type-N RF output for connection
to a range of antennas.
The MDR5800 is aimed at FCC regulated markets.
Antenna polarisation can used to co-locate multiple MDR5800 systems.
Antenna polarisation can be used to overcome interference.
3.1.1
Antenna selection (MDR5800)
The antenna type must be selected before the MDR5800 system is to be installed.
The chosen antenna must enable the system to operate with sufficient link fade
margin without excessive cost and allow the user’s ‘link availability requirements’ to
be met.
The main consideration when selecting an antenna is antenna gain measured in dBi.
A path loss analysis is highly recommended to determine the antenna gain needed for
adequate fade margin. The table below shows antenna selection guidelines for some
configurations. The distances are calculated for a 20 dB link fade margin.
Table 3 MDR25800 Antenna Selection
Antenna Type
Gain
(dBi)
Distance (Km)
Power level
(dBm)
0.15 m Flat panel
18
24
0.3 m Flat panel
24
30
24
0.6 m Flat panel
28
80
24
862-01881 Issue 6
Page 20
MDR5800 User Manual
3.2
Site Evaluation
When planning a site for a digital radio link, it is of the utmost importance that you
take the operational environment of the proposed site into account.
The combined effect of atmospheric environmental factors such as rain and lightning,
atmospheric attenuation, signal path obstruction, propagation fading, air temperature
gradients, ice build-up, wind and solar radiation can contribute towards reducing the
level of performance of the system. In the higher frequency bands, rainfall is the
main attenuation mechanism that limits error performance. Ice and snow will have a
similar effect. Severely cold and excessively warm climatic conditions outside the
scope of the operating temperature range can affect the function of the system,
especially the outdoor equipment (see Environmental Characteristics on page 64 of
this manual).
Also, if masts are not sufficiently rigid, very strong winds can affect the antenna beam
alignment and Outdoor equipment reliability due to wind force build-up and/or
vibration of the mast-mounted equipment.
3.3
Multipath Effects
The MDR5800 digital radio operates at frequencies close to 5.8 GHz and can be
influenced by the effects of multipath propagation. Understanding these effects will
help when installing an MDR5800 digital radio link and maximise the reliability of the
link.
Multipath fading occurs when the receiving antenna receives not only the direct signal
from the transmitting antenna but also a signal from the transmitting antenna that has
reflected off the ground or nearby obstacles. The reflected signal takes a longer path
to reach the receiver and acts as interference since it is not in-phase with the direct
path signal. The amplitude of the interference can be almost equal to that of the
direct path signal, thus degrading the performance of the link.
Multipath propagation is dependent on transmit frequency and the specific geometry
of the link such as antenna heights, distance between the antennas and the local
terrain. To counteract multipath propagation, the installer can change the frequency
at which the link operates or adjust the height of one or both of the antennas.
Direct RF Path
MDR5800 OU
MDR5800 OU
Reflection Path
MDR5800 IU
MDR5800 IU
User Data
User Data
Figure 4. Multipath Effects.
862-01881 Issue 6
Page 21
MDR5800 User Manual
3.4
Interference Considerations
The ISM frequency bands are used by devices that can cause interference to the
MDR5800 radio system. Interference can be avoided by careful planning of the
system installation. The available methods for providing isolation from interfering
radiators are the following:
•
Frequency diversity
•
Antenna polarisation
It is recommended to scan the proposed installation areas (spectrum analyzer) to
establish the presence of interference. The frequency spectrum should be scanned
over a sufficient time period to ensure that periodic transmissions are recorded.
Interferers will cause problems if their amplitudes are not more than 20 dB below the
intended receive power level. A link path loss calculation should be performed to
determine the expected receive power level.
The procedure for selecting the optimum antenna polarisation and system frequency
plan is the following:
•
Perform a spectral analysis at each site in the link direction using a high gain
antenna.
•
Repeat the spectral analysis for vertical and horizontal polarisation.
•
Select the polarisation with the lowest interfering levels as the system antenna
polarisation.
•
Consult the MDR5800 frequency channel plan as shown in section 2.2.1 and
select the frequency plan that would operate in an interference-free band. Give
preference to channel plans A, B and C as these are optimised for best receiver
sensitivity.
•
Install the ‘High Band’ and ‘Low Band’ Outdoor Units at the sites where they
would experience the lowest interference in their respective receive bands.
862-01881 Issue 6
Page 22
MDR5800 User Manual
3.5
Microcell Backhaul Applications of MDR5800 Digital Radios
In applications where more than one independent and separate links, need to radiate from a
central site, a number of parameters can be taken advantage of, to provide isolation and minimise
interference between these links:
•
Frequency multiplexing
•
Antenna polarisation
•
Choice of High Antenna Gain
It is important to note that these methods only provide isolation between two radio Systems, and
that power levels in the separate systems should be balanced to ensure correct operation.
3.5.1
Setting the Transmitted Power Levels
To minimise interference, received power levels should be balanced between separate radio links.
This means that transmit power levels should be set to provide similar levels of received power, as
indicated by the RSSI values of the adjacent receivers at the central site.
3.5.2
Frequency Multiplexing
The MDR5800 offers four frequency channel plans. A radio link requires two channels (one for
transmit and one to receive) to provide full duplex operation. Each radio has a high and a low subband, one that it uses for transmission and another for reception. Terminology definition: the
‘High-band Outdoor Unit’ of a system transmits on the higher of the two sub-bands. The ‘Low-band
Outdoor Unit’ of a system transmits on the lower of the two sub-bands. A system (link) always has
one High Band and one Low Band Outdoor Unit. It is important to note that unwanted transmitted
signals in adjacent frequency bands can affect other receivers operating in an adjacent band if
insufficient antenna isolation is provided. A solution is to group high-band or low-band Outdoor
Units at the central site, rather than group high and low-band Outdoor Units together.
3.5.3
Antenna Isolation
Separate links at a central site will have sufficient isolation when radio systems operate outside the
radiation beamwidth or side lobes of the system antenna. The achievable isolation can be
established by examining the measured radiation patterns of the system antennas. Directional
isolation can be used if the antenna radiation is 15 dB or lower relative to the adjacent main beam.
Antennas with high directionality will allow reduced angular separation of adjacent systems.
Antenna cross-polarisation isolation can be used for adjacent radio links, radiating in the same
direction. Typical isolation of 30 dB can be achieved using high quality antennas.
862-01881 Issue 6
Page 23
MDR5800 User Manual
This page is left blank intentionally.
862-01881 Issue 6
Page 24
MDR5800 User Manual
4 INSTALLATION
This chapter describes a recommended installation procedure for the MDR5800.
Recommended installation procedure:
1.
Install the Indoor Unit.
2.
Prepare and connect the cables to the Indoor Unit.
3.
Install the Outdoor Unit and antenna.
4.
Install the Indoor-to-Outdoor Unit interconnection cables (the power and data
cables).
5.
Turn the Indoor Unit power on.
6.
Perform the initial software setup using the supplied NMS application
7.
Repeat item 1-5 for the remote site.
8.
Align the antennas (use the RSSI voltage on the OU or the RSSI value from
the MIB or the NMS Graphic User Interface to assist with the setup).
9.
Perform a functional test and commission the link.
10.
Connect to user data.
11.
Start the system.
Installation of the MDR5800 elements is described in the following sections:
•
Installing the Indoor Unit.
•
Installing the Outdoor Unit and Antenna.
•
Installing the interconnection cables.
862-01881 Issue 6
Page 25
MDR5800 User Manual
4.1
Customer Furnished Tools and Equipment
The following table lists tools and equipment required to install the MDR5800 system.
General, IU-to-OU Interconnect
• Cable cutting and stripping tools.
• Earth lug crimp tools.
• 3 mm flat screwdriver - IU to OU power cable.
• RJ45 crimp tool - IU to OU data cable.
• Earth cable or strap rated at 45A with 5 mm earth lug for earthing the Indoor and
Outdoor Units.
• Cable ties, used to secure the cables to the mast at regular intervals.
IU
• Pozi #2 screwdriver - IU mounting in a 19" rack and the earth lug.
• 2.5mm Allen key - To change the position of the IU mounting brackets.
• DC power supply cable: minimum 2.5 mm square conductor, rated for 10 A. For
connection between the power supply and the Indoor Unit DC connector on the
rear panel.
• IU earth lug: 10-4 (10 square mm for wire and hole big enough for M4 thread)
OU
•
13 mm spanner – used for attachment of OU to mounting bracket.
•
13 mm spanner - used for attachment of OU mounting bracket to pole.
•
2.5 mm Allen key - used to tighten OU connection box cover fasteners.
•
OU earth lug: 10-8 (10 square mm for wire and hole big enough for M8 thread)
Please refer to Chapter 7 for details on the data and RF cables, which are also
customer furnished equipment.
862-01881 Issue 6
Page 26
MDR5800 User Manual
4.2
4.2.1
Indoor Unit
Introduction
This section describes the recommended installation procedure for the Indoor Unit.
The Indoor Unit is designed for mounting in the DIN 41494 (19") racking standard and
occupies a 1U high slot. Desktop mounting is also possible.
The Indoor Unit’s payload (nE1, nT1 and 10BaseT Ethernet) and Service Channel
(‘Wayside serial’) data interfaces and Element Management interface are located on
the front panel. Input Power, Auxiliary alarm and ‘IU/OU Interconnect’ interfaces are
located on the rear panel, suitable for rack installations.
IU/OU Power
Interconnect
DC In
IU/OU Data
Interconnect RJ45
Fuse
Holder
Auxiliary IO
IU/OU Link LED
ON/OFF
Switch
Ground
Terminal
The recommended installation procedure for the Indoor Unit is the following:
4.2.2
•
Install the Indoor Unit in the rack.
•
Earth the Indoor Unit.
•
Connect the DC power supply.
•
Connect Payload data ports (front panel).
•
Connect Auxiliary In/Out port (optional).
•
Connect Service Channel (Wayside) serial port (optional).
•
Connect the Element Manager port using the supplied cable (front panel).
Installing the Indoor Unit in a Rack
1.
Slide the Indoor Unit into the 19" rack and secure to the rack using four M6 x 18
mm screws.
2.
Earth the Indoor Unit by connecting the earth cable or strap between the station
earth and the earth stud on the Indoor Unit rear panel.
862-01881 Issue 6
Page 27
MDR5800 User Manual
4.2.3
Connecting a DC Power Supply
WARNING –See section 8.4 for specification of the power supply.
1.
Observing the polarity of the supply, wire up the supplied power connector
cable plug and connect it to the DC supply (21 to 56 V) through a minimum 5 A
circuit breaker.
2.
Check the supply voltage using a multimeter.
3.
Secure the connector screws to the unit.
DC Power Connector Pinouts
Indoor unit connector
GREY
Pin
No
Signal
DC POWER
DC POWER RETURN
2-pin Wieland Type 8213
+ DC -
862-01881 Issue 6
Page 28
MDR5800 User Manual
4.2.4
Balanced Payload Data
1.
Assemble the (nE1) / (nT1) payload data input and output cable. See the table
below for Indoor Unit connector pin assignments.
2.
Connect the payload data cable to the DB25 connector on the front panel of the
Indoor Unit.
D-Type
Payload
Data
Connector
Pin Name
Tributary
Direction
Pin #
GND Earth
RTIP1
RX +
RRING1
RX -
GND Earth
TTIP1
TX -
TRING1
TX +
GND Earth
N/A
GND Earth
N/A
RRING0
RX +
10
RTIP0
RX -
11
GND Earth
12
TRING0
TX -
13
TTIP0
TX +
14
TRING2
TX -
15
TTIP2
TX +
16
GND Earth
17
RRING2
RX+
18
RTIP2
RX-
19
GND Earth
20
TTIP3
TX-
21
TRING3
TX+
22
GND Earth
23
RTIP3
RX+
24
RRING3
RX-
25
GND Earth
862-01881 Issue 6
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Page 29
MDR5800 User Manual
4.2.5
Connecting Auxiliary In/Out (Optional)
The auxiliary in/out port is used to:
•
Monitor switch-closure events using two isolated inputs.
•
Control line connections using normally-open and normally-closed relay
outputs.
Connect the port:
1.
Assemble an auxiliary in/out cable using a High density 15 way D-type male
connector according to connector pin assignments shown in Table 4.
2.
Connect to the cable Indoor Unit auxiliary in/out connector.
3.
Secure the connector using locking screws.
Table 4. Auxiliary In/Out Connector Pin Outs
Indoor unit connector
Pin
No
Signal
15-pin High density D-type female
OUTPUT 1 COMMON
OUTPUT 1 NORMALLY-OPEN
OUTPUT 1 NORMALLY-OPEN
OUTPUT 1 NORMALLY-CLOSED
OUTPUT 1 NORMALLY-CLOSED
OUTPUT 1 COMMON
OUTPUT 2 COMMON
OUTPUT 2 COMMON
OUTPUT 2 NORMALLY-OPEN
10
OUTPUT 2 NORMALLY-OPEN
11
OUTPUT 2 NORMALLY-CLOSED
12
INPUT 1
13
INPUT 1 RETURN
14
INPUT 2
15
INPUT 2 RETURN
10
15
862-01881 Issue 6
11
Page 30
MDR5800 User Manual
4.2.6
Connecting the Service (Wayside) Serial Channel (Optional)
This ‘clear’ serial channel can transport up to 115,200 bps across the radio link. This
channel does not interfere with the payload data channels. The port is configured as
DCE.
1.
Connect the serial data interface cable to the Service channel connector on the
Indoor Unit rear panel. The supplied serial data cable can be used to connect
to this port after the software setup is completed.
2.
See the table below for Indoor Unit connector pin assignments when a custom
cable needs to be assembled.
3.
Secure the connector using locking screws.
Service Channel Connector Pinouts
Indoor Unit connector
Pin
No
Signal
9-pin D-type Female
Connector
TD
RD
DTR
GROUND
DSR
RTS
CTS
4.2.7
Connecting the Element Manager Port
The Element Manager port is used to connect the Indoor Unit to a PC/Laptop serial
port. This enables the Indoor Unit to be configured using the supplied NMS software
or controlled via a PPP-dialup connection. The port can be connected to using the
supplied serial data cable. The port is configured as DTE.
862-01881 Issue 6
Page 31
MDR5800 User Manual
4.3
Outdoor Unit
Before installing the MDR5800 Outdoor Unit, ensure that a suitable mast is used for
the antenna and that the Outdoor Unit installation is firmly in position. The pole
diameter must be between 50 and 102 mm.
CAUTION –ENSURE THAT THE POLE IS EARTHED FOR LIGHTNING
PROTECTION.
4.3.1
MDR5800 Outdoor Unit
Follow these steps to install the MDR5800 Outdoor Unit:
4.3.1.1
1.
Install the system antenna.
2.
Adjust the mounting bracket to be slightly bigger than the pole diameter.
3.
Secure the mounting bracket to the pole.
4.
Secure the Outdoor Unit to the bracket using the screws on each bracket.
5.
Connect the Outdoor Unit to the pole electrically by connecting the earth cable
or strap between the pole earth and the Outdoor Unit earth point.
6.
Connect the type-N RF output connector to the system antenna through an inline lightning protection unit in areas with lightning activity.
7.
Cover the connectors using an ultra violet protective, self-vulcanising tape.
RF Connection
1.
2.
3.
4.
5.
862-01881 Issue 6
The RF port is an N-type female connector.
The N-Type connector is used to connect to the antenna, typically using coaxial
transmission line.
1/2" or 5/8” coaxial cables are recommended. Coaxial cable that is 7/8” or
larger can exhibit moding at 5.8 GHz and is not recommended for 5.8 GHz
radios.
Do not use right angle N-type connectors with the 5.8 GHz radios: they may
present high loss at 5.8 GHz.
Do not use low quality cables. Some cable types, such as RG-8, may have too
high a loss at 5.8 GHz.
Page 32
MDR5800 User Manual
4.4
Interconnection Cable Installation
Follow these steps to install the Indoor Unit to Outdoor Unit interconnection cables.
CAUTION
DO NOT OVER TIGHTEN THE CABLE STRAPS ON THE CABLES AND
DO NOT FASTEN THE STRAP LOCKING MECHANISM OF THE CABLE
STRAP ONTO THE CABLES.
1.
On the OU side, connect an RJ45 plug to the data cable. Place the RJ45 plug
into the RJ45 socket in the Outdoor Unit connection box.
2.
On the OU side, connect the DC power leads within the Outdoor Unit
Connection Box. Use the +Ve and Return connections.
RJ45 Socket
Return
+Ve
"Chassis"
3.
Close the Outdoor Unit Connection Box Cover using a 2.5mm Allen key. Make
sure the rubber gaskets seal correctly over the power and data cables.
4.
Using cable ties, secure the cable to the pole at regular intervals.
5.
On the IU side, connect an RJ45 plug to the data cable. Place the RJ45 plug
into the RJ45 socket in the rear of the Indoor Unit.
6.
On the IU side, connect the DC power leads to the supplied GREEN Phoenix
plug. Insert this plug into the green socket on the rear-panel of the IU.
7.
The user can see that there is a suitable IU/OU data interconnection if the
‘IU/OU Link’ LED on the rear-panel of the IU is lit up green.
CAUTION
862-01881 Issue 6
UNDO THE SCREWS OF THE “CONNECTION BOX” IN A UNIFORM
MANNER. THIS ENSURES THAT THE “CONNECTION BOX” GASKET
MATERIAL RELEASES STRESS UNIFORMLY AND DOES NOT LEAD TO
THE SECURING SCREWS BEING BENT DUE TO THE PRESSURE
PLACED ON THE CONNECTION BOX LID.
Page 33
MDR5800 User Manual
4.4.1
INTERCONNECTION CABLE WIRING DESCRIPTION
TOP VIEW (LOCKING
TAB UNDERNEATH)
RJ-45 PLUG
862-01881 Issue 6
Pin
DTE (on
INDOOR
UNIT)
DCE (on
OUTDOOR
UNIT)
Wiring
TxD+
RxD-
Orange/White
TxD-
RxD+
White/Orange
RxD+
TxD+
Green/White
4†
TxC+
RxC+
Blue/White
5†
TxC-
RxC-
White/Blue
RxD-
TxD-
White/Green
7†
RxC+
TxC+
Brown/White
8†
RxC-
TxC-
White/Brown
Page 34
MDR5800 User Manual
NOTE
† VERSION 1 AND 2 RELEASES OF THE HARDWARE (INDOOR AND OUTDOOR UNITS)
CANNOT BE USED INTERCHANGEABLY. FOR VERSION 2 IU & OU HARDWARE, USE OF
TxC+, TxC-, RxC+, RxC- FALLS AWAY AND ONLY TWO (2) TWISTED PAIRS ARE REQUIRED.
862-01881 Issue 6
Page 35
MDR5800 User Manual
5 ANTENNA ALIGNMENT AND SOFTWARE SETUP
This chapter describes the procedure for software setup and antenna alignment. The
setup is done with a PC running the supplied NMS software. See chapter 6 for details
on using the NMS software.
5.1
Installation Equipment Required
The following tools and instruments are required for software setup and aligning the
antenna:
5.2
•
RSSI test cable
•
Voltmeter
•
Spanner (see appropriate details in installation chapter depending on the
antenna being used)
•
PC with NMS software and supplied serial data cable.
•
Binoculars (optional) used for locating the far end site. This will assist in the
antenna alignment operation.
•
GPS or Standard Compass (optional) used for locating the far end site. This
will assist in the antenna alignment operation.
•
Bit Error Rate Tester and connecting leads.
Information Required
You should know:
5.3
5.3.1
•
the proposed frequency channel plan for each station.
•
the expected receive level based on the chosen system configuration and a
pathloss analysis.
Antenna Alignment
Introduction
The MDR5800 should be installed on both sites before alignment starts. Perform the
following steps at both stations:
1.
Switch the Indoor Unit power ON.
2.
Install and run the MDR5800 NMS Software application.
3.
Configure the radio channel plan as required.
4.
Set the transmitted power to maximum.
5.
Perform a RF loopback test at each site before starting the alignment
procedure.
862-01881 Issue 6
Page 36
MDR5800 User Manual
5.3.2
Alignment Procedure
1.
Locate the far site and point the antenna to the antenna at the far site, as
accurately as possible using binoculars or a compass.
2.
Connect the multimeter to the RSSI connector on the Outdoor Unit using the
supplied RSSI test cable and set the multimeter to measure volts.
3.
Check the RSSI level and refer to the figure below for received power level.
4.
Align the antenna until the maximum RSSI is attained.
5.
Secure the antenna.
6.
Measure the RSSI level and record the value (see section 5.7).
7.
Compare with the value with that calculated for the link i.e. using the pathloss
calculation done when planning the link.
Figure 5. RSSI as a function of RF input level
The front panel RF Link LED, the Received Signal Strength Indicators (RSSI : on
NMS, via SNMP or as an Electrical signal on the Outdoor Unit), Carrier-detect (NMS,
SNMP) and Frame Lock (NMS, SNMP) indicators are available to assist with link
installation and alignment.
5.3.3
Set Transmitted Power Level
It is good practice to match received power levels by adjusting transmitted powers if
co-located systems are being installed. This is important to avoid interference
between co-located systems. An attenuator can be fitted between the Outdoor Unit
and the antenna if the power level cannot be sufficiently reduced. The dBm output at
the OU N-type connector (socket) levels are set via the NMS or using a SNMP
Management application.
862-01881 Issue 6
Page 37
MDR5800 User Manual
5.4
Software Setup
Refer to chapter 6, for setting up the following:
5.5
•
Payload interface.
•
Service Channel (Wayside) serial port.
•
Auxiliary in/out port.
•
General link parameters.
Functional Test
After completing the physical installation of the Indoor Units, antennas, Outdoor Units
and the interconnection cables, you need to commission the system. This procedure
describes how to set up the minimum requirements for successful MDR5800 system
operation.
5.5.1
Link Bit Error Rate Performance Test
To start : when the link is setup correctly, the RF Link LEDs on both IUs on both sides
of the RF link should be GREEN.
When the link has been setup and is running error-free:
1. Clear the Indoor Unit Log using Reset Button Position ‘2’
2. Clear the Indoor Unit Errors using Reset Button Position ‘1’
Perform a link bit error rate performance test as follows:
•
Connect a bit error rate tester to the payload interface of the link.
•
Run data over the link for a period of 24 hours.
•
Record the BER.
•
Record the LED statuses.
Check the Indoor Unit Packet Error Results via the NMS or via SNMP access to the
Indoor Unit MIB – for the NMS, right-click on the antennas in the NMS for either side
of the link and select the “Diagnostic/Error Monitor” option. Record the results by
saving the data to a file. For SNMP access, use a MIB Browser and check the
mdrmteRFLinkPerf and mdrmteG826 Performance groups.
862-01881 Issue 6
Page 38
MDR5800 User Manual
Record all results on a test record. See MDR5800 Test Record, section 5.7 for an
example.
862-01881 Issue 6
Page 39
MDR5800 User Manual
5.6
MDR5800 Installation Record
Parameter
Unit
Site A
Site B
Site Name
Antenna Type
RF cable length
Meters
Lightening protection unit
Yes/No
Interconnecting cable length
Meters
Outdoor Unit serial number
Indoor Unit serial number
Outdoor Unit earthed
Yes/No
Indoor Unit earthed
Yes/No
Power Supply
Volts DC/AC
Date
Name
Signature
Performed by
Approved by
862-01881 Issue 6
Page 40
MDR5800 User Manual
5.7
MDR5800 Test Record
Parameter
Unit
Site A
Site B
Frequency channel plan:
Transmit
A/B/C/D
Receive
A/B/C/D
If D – List
Transmit and
Receive
Frequencies
[MHz]
Transmitter output power
dBm
Receiver input level (ON)
Volts
Receiver input level (ON)
dBm
Receiver input level (OFF)
Volts
Receiver input level (OFF)
dBm
Calculated input level
dBm
Fade margin
dB
Frame Lock indicator
Colour
Fixed attenuator
dB
BER-test
Hours
BER
Alarm Indicators
Clear
(Yes/No)
Date
Name
Signature
Performed by
Approved by
862-01881 Issue 6
Page 41
MDR5800 User Manual
This page is left blank intentionally.
862-01881 Issue 6
Page 42
MDR5800 User Manual
6 NMS SOFTWARE
6.1
Introduction to the Network Management System
The purpose of the Network Management System, hereafter called the NMS, is to
allow you to configure, manage or interrogate the following primary functional
elements of a Digital Radio Link (Local or Remote Stations within the link):
•
Indoor Unit
•
Outdoor Unit
The NMS is a PC-based software package that provides you with a graphical interface
that is used to perform on-site element management of a Microwave Digital Radio
(MDR) System. It allows you to configure, manage and interrogate the MDR System
by selecting various menus and options.
It provides extensive management functions on site and, via the microwave radio link,
can be used to access the remote MDR station.
The hardware as well as the software constituting the NMS is collectively called the
NMS Terminal.
The NMS Terminal is the principal system support equipment associated with the MDR
System for system installation and commissioning.
It connects to a designated NMS Terminal port (labelled Element Manager) on the
front panel of the Indoor Unit of a MDR Station installation, by means of a serial data
interface (this cable is supplied in the IU box).
The NMS communicates with SNMP agent software that is contained in each
MDR5800 Indoor Unit. The NMS communicates with the agent’s software: the
software enables a unit to interpret MIB (Management Information Base) commands
via SNMP (Simple Network Management Protocol).
6.2
General Information
1.
To select a button/option, simply click the appropriate button/option.
2.
Move the mouse pointer to the different areas of the screen. When the pointer
changes into a hand, this indicates that the area can be activated by a left
mouse button click. In some cases (opto inputs, relays, payload interfaces),
hold the mouse hand cursor over the particular area of the screen and a hint
appears indicating the state associated with the selected item. If the pointer
changes to vertical bar, then the field may be edited if clicked.
3.
The main screen has pull-down menus that are activated by clicking on the
words of the menu (menu items).
862-01881 Issue 6
Page 43
MDR5800 User Manual
4.
6.2.1
A general help facility is available by clicking on the Help button on the Main
screen. This opens the help file for the Network Management System. From
here, you can search for a particular topic using the Index facility or you can
use the Find facility to search for key words connected to the specific
information required.
Microwave Digital Radio
A MDR link consists of at least one complementary pair of MDR5800 stations that
may be extended over longer distances by linking further station pairs in a multiplehop configuration. A single MDR5800 station comprises an Indoor Unit and an
Outdoor Unit interconnected by a data cable (CAT5) and a 2-core DC supply cable.
862-01881 Issue 6
Page 44
MDR5800 User Manual
6.3
Main Screen
This screen displays the names of the stations/sites, their IP addresses and allows
you to view or edit the parameters and status for the entire station. Indoor Unit and
Outdoor Unit details are accessed by using the mouse to select the Indoor Unit and
Outdoor Units of the local or remote sites.
Note that if the local Indoor Unit is offline, all controls for both station IUs and OUs are
'greyed out' and thus unavailable. If the Outdoor Unit is offline and the Indoor Unit is
online, then only the Outdoor Unit controls are 'greyed out' and unavailable.
The Main screen shows a local station on the left hand side of the screen and a
remote station on the right hand side of the screen.
The Main Menu area provides pull-down menus and controls that allow you to
configure and monitor system link parameters and to perform basic tasks.
The station elements are displayed initially with no colours, but the controls in the
blocks change colours when the NMS attempts to communicate with the link’s primary
elements.
The control buttons on the screen are short-cuts to MIB elements in the Indoor Units.
Move your mouse pointer to the required area of the screen and when the mouse
pointer changes into a 'hand', click the right mouse button to display more detailed
information. Click the left mouse button to activate relays and loopbacks.
862-01881 Issue 6
Page 45
MDR5800 User Manual
6.3.1
Link Elements Areas
The Link Elements Areas on the Main Screen show an abbreviated status of the
Indoor and Outdoor Unit interfaces. Move your mouse pointer to each block until a
hand appears and click the right mouse button (right click) to see more information on
each element.
If both Stations are online, the status bar at the bottom of the screen shows that the
stations are being polled. If there is no communication with the remote side, the
remote station will be greyed. If there is no communication with the local side’s
Outdoor Unit, it will be grey.
Display Indicators
•
A GREEN status indicator shows that there are no current alarms or errors.
•
A YELLOW status indicator shows that there was a historic alarm condition.
•
A RED status indicator shows that there is a current alarm condition.
The main screen shows a RSSI (Received Signal Strength Indication) bar graph in
dBm.
862-01881 Issue 6
Page 46
MDR5800 User Manual
6.4
6.4.1
NMS Menus
Main Screen Menus
The following pull-down menus are available from the Main menu:
Menu
Sub-item
Result
File
Exit
Exit from NMS.
Options
Communications
Allows setup of which communications port is
used on the PC or Laptop for communication
with the Indoor Unit via the front panel Element
Manager Serial Port.
It is possible to purchase upgrades for E1/T1
Indoor Units (upgrades to 2E1/T1 or 4E1/T1).
The user contacts the factory and provides the
Indoor Unit Bar Code number details. The
factory then supplies a “Tributary Code”, unique
to the Indoor Unit, which is entered using the
MIB (Version 1 & 2 products) or using the NMS
(Version 2 product).
Local Trib Code
Spectrum
Analyzer
862-01881 Issue 6
Remote Trib Code
See above.
Local User
Configuration
Allows the user to set the access control
settings for the local station equipment to allow
the user to log on as an ‘Administrator’ with full
read/write configuration access or with ‘Readonly’ access. (Note: This option is only
available if the IU firmware has been supplied
with secure-features activated – the default is
NOT to have this feature activated).
Remote User
Configuration
Allows the user to set the access control
settings for the remote station equipment to
allow the user to log on as an ‘Administrator’
with full read/write configuration access or with
‘Read-only’ access. (Note: This option is only
available if the IU firmware has been supplied
with secure-features activated – the default is
NOT to have this feature activated).
Allows the user to examine the RF spectrum
using a RSSI (received signal strength
indicator) value measured in the Outdoor Unit.
If interference exists, this feature allows the
user to examine the spectrum and decide
where to set the transmit and receive
frequencies for the local and remote stations.
Page 47
MDR5800 User Manual
6.4.1.1
Exiting from the NMS : File/Exit
You can exit from the NMS as follows:
Click on the Exit option from the File pull-down menu on the Main screen.
You are prompted for confirmation of the shutdown – answer OK or Cancel to this
prompt.
6.4.1.2
Communications
This menu item allows you to configure the following NMS communications
parameters:
•
Serial Port
•
Polling Cycle
The users can either:
Use the Load Defaults option or change to the required settings and then use the
Apply Changes button.
Use the Exit button to exit without any changes being made.
6.4.1.2.1
Serial Port
Configure the serial port as follows:
6.4.1.2.2
1.
Select Communications from the menu on the main screen.
2.
Select the required port: COM1, COM2, COM3 or COM4.
Polling Cycle
Set the polling cycle (minimum 3 seconds). This determines how often the
information is updated.
6.4.1.3
Local User Configuration
Allows the user to set the access control settings for the local station equipment to
allow the user to log on as an ‘Administrator’ with full read/write configuration access
or with ‘Read-only’ access (only available with “security-enabled” versions of Indoor
Unit firmware).
The user enters a ‘Username’, ‘Password’, ‘Access level’ and activates the user via an
With ‘Administrator’ access, the user can add new users.
Use the Apply Changes button once the changes are to be made in the Indoor Unit.
Use the Exit button to exit without any changes being made.
862-01881 Issue 6
Page 48
MDR5800 User Manual
6.4.1.4
Remote User Configuration
As above, but controls access to the remote station’s MIB.
6.4.2
Main Screen Short-cut Buttons
Short-cut buttons are provided to allow quick access to the above menu items.
6.5
Indoor Unit Configuration
The Indoor Units have graphical interface controls that allow you to configure the
following items:
•
Payload Data Interface Port
•
Service Channel Port
•
‘Loopback to Line’ and ‘loopback to RF Link
•
Opto Inputs
•
Relays
Payload is from the user’s ‘line’ equipment to the Indoor Unit Payload Data DB25
connector and RF Link is from Antenna to Antenna.
Right click on the Indoor Unit to get the following options
•
Time/date entry
•
Station Status
•
Station Properties
•
Station Info (Serial number, software version, bootkernel version)
•
View Event Log
•
Maintenance
6.5.1
6.5.1.1
Controls
Payload Data Interface Port
A label/name can be assigned to any of the payloads.
6.5.1.1.1
E1 Port Line Code
Default setting is HDB3. However, it can be set to either HDB3 or AMI.
862-01881 Issue 6
Page 49
MDR5800 User Manual
6.5.1.1.2
T1 Port Line Code
Default setting is B8ZS. However, it can be set to either B8ZS or AMI.
6.5.1.2
6.5.1.3
Payload Error Monitoring
Term
Name
Description
AIS
Alarm Indication
Signal
This is an all 1’s detection, incoming to the
equipment on the payload tributaries. Note that
there is independent monitoring for AIS on each
of the 4 tributaries.
LOS
Loss of Signal
This is a loss of signal detected on the input to the
payload data port tributaries. Note that there is
independent monitoring for LOS on each of the 4
tributaries.
Service Channel Port
The service channel serial port provides a means to send asynchronous data across
the link to the far side service channel port. Service channel ports can be connected
back-to-back (i.e. Remote to Local) at a remote site so as to extend the channel in a
multi-hop network. The service channel data is multiplexed with IP data onto the RF
overhead link. Priority is given to IP data.
Use the Load Defaults option or change to the required settings and then use the
Apply Changes button.
Use the Exit button to exit without any changes being made.
6.5.1.3.1
Baud Rate
Default setting is 115200 bit/s (Ver 1, 2).
6.5.1.3.2
Data Width
Default setting is 8 bits.
6.5.1.3.3
Parity
Default setting is None.
6.5.1.3.4
Flow Control
Default setting is None.
6.5.1.3.5
Stop Bits
Default setting is 1 Bit.
862-01881 Issue 6
Page 50
MDR5800 User Manual
6.5.1.4
Relay Scripting (NA for Version 1, 2 releases)
Configure the various alarms that will switch on Indoor Unit relays as required. There
are two relays on each Indoor Unit. Each relay can be programmed to switch on
based on the occurrence of Payload or RF Link errors detected in the LOCAL/NEAR
and/or REMOTE/FAR Indoor Units. The user can visually select those errors that will
trigger the respective relays.
The following built-in test status can be monitored on a link:
RF Link
Link Unavailable
Frame Unlock
Minor PER Exceeded
ESR Exceeded
Payload Interface
LOS
AIS
Use the Apply Changes button to change settings.
Use the Exit button to exit without any changes being made.
6.5.1.5
Indoor Unit Loopback Controls
These controls allow you to set the loopbacks on the payload data.
•
IU Loopback to Line - Used to loopback the data on the payload interface so
that incoming user payload data is sent straight back to the user. The payload
data does not go out over the RF link.
•
IU Loopback to RF Link - Used to loopback the payload (Indoor Unit)/Outdoor
Unit data so that payload data arriving over the RF link is looped and sent back
across the RF link.
Perform a loopback as follows:
1.
Select the Loopback Type by choice of arrows on the IU being tested.
2.
Select the Loopback Timeout Time (in seconds). If enabled, the Loopback
state will cancel after Time seconds and the unit will return to normal operation.
3.
Click on the Loopback Timeout Enable checkbox.
4.
Click on the Apply Changes button.
862-01881 Issue 6
Page 51
MDR5800 User Manual
6.5.2
6.5.2.1
Menu Items
Date/Time Entry
In his menu, the user has the option of entering the:
•
Date (change date using the calendar display)
•
Time (change time using the spin button on the right-hand side of the control or enter
manually).
•
The user had the option of ‘fetching’ the date and time from the PC or Laptop and using this
information.
•
Use the Apply Changes button once the update in the Indoor Unit is to be made.
6.5.2.2
Station Status
6.5.2.3
General Status Indicators
These errors occur during the phase of continuous error checking. Errors are latched
until the operator clears them on the NMS.
The following is a list of possible error indicators as well as the possible faults and
corrective actions to solve each error.
Error Displayed
Possible Faults and Corrective Actions
General Faults
Outdoor Unit Not
Responding
•
The Outdoor Unit simply doesn't respond to any messages sent to it
by the Indoor Unit. The Outdoor Unit could possibly be damaged or
the cables to the Outdoor Unit are disconnected from the Indoor
Unit or damaged.
Outdoor Unit
Comms Error
•
Message from Outdoor Unit too long (data corruption).
•
Received message frame invalid – the Outdoor Unit messages
follow a strict data link layer frame protocol. There could data
corruption.
•
Partial message received from Outdoor Unit - remainder did not
arrive in time (Outdoor Unit switched off?).
•
CRC Error – data corruption.
•
Software queuing/buffering errors in the Indoor Unit firmware.
•
Wayside port queue overruns - too high data rates or failed
overhead link.
•
Comms Error - errors caused by Rx Overrun (Indoor Unit processor
could not service the received characters fast : too high data rates),
parity error if odd or even parity enabled (data corruption or
incorrect configuration), framing error (no valid stop bit where one
was expected - invalid baud rate or data width or parity
Wayside Port
Comms Error
862-01881 Issue 6
Page 52
MDR5800 User Manual
configuration or data corruption) or break detected (line shorted
causing permanent break or corruption).
Overhead Link
Comms Error
•
Overhead PPP link error: the buffering system of the overhead link
cannot process data fast enough and received messages have been
discarded (the software cannot process the data fast enough).
Ethernet Comms
Error
•
The buffering system of the interface cannot process data fast
enough and received messages have been discarded (the software
cannot handle the data fast enough).
Element Manager
Comms Error
•
Message from PC or laptop too long (data corruption).
•
Software queuing/buffering errors in the NMS firmware.
Alarm 1 on
A digital optically isolated input used for general site alarm monitoring
(Auxiliary Input 1).
Alarm 2 on
A digital optically isolated input used for general site alarm monitoring
(Auxiliary Input 2).
6.5.2.3.1
Power-up Self Test Indicators
The following is a list of errors that can occur during the power-up phase of operation.
These errors may only be cleared by switching the Indoor Unit off and then on again.
The list also describes the possible faults and corrective actions to solve each error.
Error
Possible Faults and Corrective Actions
FLASH
The Application FLASH memory test failed. Only a faulty Application
Flash device can cause this fault and the Application Flash device will
have to be replaced.
DRAM Error
The DRAM test failed. Only a faulty DRAM device can cause this fault
and the DRAM will have to be replaced.
SRAM Error
The battery-backed up SRAM test failed. Only a faulty SRAM device or
battery can cause this fault and the Battery and/or SRAM will have to be
replaced.
Watchdog Reset
Software error. Please contact the supplier. Processor triggered a
watchdog restart because watchdog is no longer being toggled by the
application. Either the application has become too overloaded or this is a
software or design fault.
Hard Reset
A hardware reset was performed. This is an indication of the last reason
for a reset and does not constitute a fault condition.
Unknown Reset
Another reset detected by the Indoor Unit’s microprocessor (other than
Watchdog and Hard Reset) was performed. This is an indication of the
last reason for a reset and does not constitute a fault condition.
Line Interface
Error
The line interface transceiver is not responding as expected and is most
likely faulty. The transceiver is programmed for operation and then
checked to see that the values programmed are valid (read correctly).
FPGA
The FPGA register interface is not responding correctly and is most likely
faulty. The FPGA is programmed for operation and then checked to see
that the values programmed are valid (read correctly).
Real Time Clock
The Real Time Clock (RTC) is not responding correctly and is most likely
faulty. The RTC is programmed for operation and then checked to see
that the values programmed are valid (read correctly).
862-01881 Issue 6
Page 53
MDR5800 User Manual
Use the Clear button to clear alarm indicators.
6.5.2.4
Station Properties
In this menu, the user has the option of entering the:
•
Indoor Unit Station name
•
IP address of the Indoor Unit
•
Netmask
Use the Apply Changes button once the update in the Indoor Unit is to be made.
6.5.2.5
Station Info
This information allows you to view the build state details of the primary hardware and
software components of the selected Indoor Unit. Information provided is read from
the Indoor Unit microprocessor.
Serial Number (Programmed into the Indoor Unit at time of manufacture),
Software Version (Programmed into the Indoor Unit during any software upgrade) and
Bootkernel Version Number (Programmed into the Indoor Unit at time of
manufacture).
6.5.2.6
Indoor Unit Event Log
This screen is used for the viewing of the event log file. In the event of a persistent
field fault it will be useful for you to save the logged data file and send it, with the
faulty unit, to the repair department to assist in the repair of the unit. There is a
maximum of 100 records stored in the Indoor Unit (one filled, earlier records are
discarded in favour of newer records). The event log file is displayed from oldest to
youngest i.e. ascending order by time. The log file columns are:
Date – the date of the event dd-mm-yyyy.
Time – the time of the event in hh:mm:ss.
Type – the type of event.
Event – a text description of the event itself.
Use the Clear Log button to clear the log in the Indoor Unit.
Use the Refresh button to collect the log from the Indoor Unit.
Use the Save button to save the log on the NMS PC or Laptop platform.
Use the Exit button to exit the Event Log menu.
862-01881 Issue 6
Page 54
MDR5800 User Manual
6.5.2.7
Maintenance
This screen provides the ability to upgrade the Indoor Unit firmware on the local/near
Indoor Unit only.
The user selects the file to be uploaded using the ‘Select File’ button. A file selection
dialogue is presented which provides a means to retrieve the file from any directory
on any drive.
Once the file is selected, the following information is displayed on the screen:
Application version - the Indoor Unit application code software version number as
read from the Indoor Unit application).
Date and time - the Indoor Unit application code software date as read from the
Indoor Unit application.
Bootkernel version - the Indoor Unit boot kernel code software version number as
read from the boot kernel.
Upload Status box
Used to display the steps being undertaken during the programming and verification
process. As the upload process proceeds, the user is informed of progress.
Verification of upload is done once the file has been uploaded into DRAM. Thereafter
the data is loaded into ‘Application Flash’. The latest version is uploaded into one ½of
the flash device. The other half maintains the old version. In this way, there is an
option to revert to the old version should there be an upload problem.
6.5.2.7.1
Programming an Indoor Unit
This procedure allows you to program factory-supplied firmware into the Application
Flash IC on the Indoor Unit. Proceed as follows:
1. Switch off the Indoor Unit. Run the NMS application and connect to the Indoor
Unit via the Element Manager Port.
2. Select the file to be uploaded into the Indoor Unit.
3. Switch on the Indoor Unit.
4. The upload process will proceed and the user is informed of the progress via the
status box.
5. Once complete, the IU verifies the program code is valid.
6. Once verified, the data is transferred into the IU’s Application Flash.
7. Once the code is programmed, the Indoor Unit application is restarted by the boot
kernel.
862-01881 Issue 6
Page 55
MDR5800 User Manual
6.6
Outdoor Unit Configuration
6.6.1
6.6.1.1
Controls
Loopback Controls
These controls allow you to set the loopbacks on the payload data.
•
OU Baseband Loopback - Used to loopback the data at baseband processor
level in the Outdoor Unit so that incoming user payload data is sent back to the
user via the IU/OU interconnection data cable.
•
OU RF Loopback - All RF data sent out of the Local Indoor Unit to the Outdoor
Unit is looped back at the output stage of the Outdoor Unit and returned to the
Indoor Unit.
Perform a loopback as follows:
1. Select the Loopback Type by choice of arrows on the OU being tested.
2. Select the Loopback Timeout Time (in seconds). If enabled, the Loopback state
will cancel after Time seconds and the unit will return to normal operation.
3. Click on the Loopback Timeout Enable checkbox. If not enabled, then only the
NMS can cancel the loopback condition.
4. Click on the Apply Changes button.
6.6.2
6.6.2.1
Menu Items
Station Configure
The current Outdoor Unit parameters for Channel plan, Transmit Power and
Autorecovery are displayed. All Outdoor Unit operational parameters are stored in
the Indoor Unit. The Outdoor Unit is unaware of what it has been programmed to do.
The operational parameters are programmed automatically after a power up.
This screen allows you configure the following Operational Outdoor Unit parameters:
•
Frequency channel Plan.
•
Transmit Power.
862-01881 Issue 6
Page 56
MDR5800 User Manual
6.6.2.1.1
Frequency Channel Plan
The MDR Radios operate in the 5.725 GHz to 5.850 GHz ISM frequency band. The
MDR5800 has predefined frequency channel plans (termed A, B, C and D).
6.6.2.1.2
Transmit Power
The Transmit power ranges from 2 to 24 dBm. There is also a mute setting.
6.6.2.1.3
Autorecovery
This feature is used if the user is installing a link from one side and there is no
technical staff assistance on the opposite side of the link. It mitigates against the link
failing and not being able to be re-established.
If autorecovery is enabled, the required operational RF parameters are programmed
into the Outdoor Units by the local and remote Indoor Units. If communication
between the two Indoor Units has not reactivated within 5 seconds, the previous
(working) ‘default’ RF parameters are programmed into the respective Outdoor Units.
6.6.3
OU Station Info
The OU Station Info screen provides a brief report of the build state of the Outdoor
Unit:
6.6.4
•
Serial number – loaded into the Outdoor Unit at time of manufacture.
•
Software version – loaded into the Outdoor Unit at time of manufacture.
•
High Band Transmitter – affects the way the channel plan is implemented on
the Outdoor Unit.
•
Low Band Transmitter – affects the way the channel plan is implemented on the
Outdoor Unit.
•
FCC Regulations (None, FCC, Other).
Outdoor Unit Status
This screen allows you to view the following Outdoor Unit status information:
•
Last Restart. This indicates the reason why the Outdoor Unit restarted, e.g.
Power On, Watchdog Timeout.
•
OU Lock Detect Status: indicates if there is a loss of lock of the IF, Transmit or
Receive path phase-locked oscillators in the OU.
862-01881 Issue 6
Page 57
MDR5800 User Manual
6.7
RF Link Error Status Monitoring
Selected by right-clicking the relevant antenna and choosing the Diagnostics/Error
option.
6.7.1
RF Link Status
Link Unavailable
The RF Link is considered not available (see Link Availability definition
on next page).
Frame Unlock
RF link only. It looks at data received from the link. If the link is quality
is poor, i.e. high PER at the RF level, ‘Frame Unlock’ is the result. AIS
is sent from the transceiver (from link direction) as long as ‘Frame
Unlock’ is true and no reliable data is available.
Packet Error Rate
Fault
The PER Monitoring has been enabled and the Instantaneous PER has
exceeded the configured PER Fault Threshold for the RF link.
ESR Exceeded
RF Errored Second Ratio has been exceeded due to Packet errors on
the RF link.
SESR Exceeded
RF Seriously Errored Second Ratio has been exceeded due to Packet
errors on the RF link.
BBER Exceeded
RF Background Block/Packet Errors Ratio has been exceeded due to
block errors on the RF link.
Default RF
Parameters
Activated
The Operational RF parameters were programmed into the Outdoor Unit
by the local and remote Indoor Units. Communication between the two
Indoor Units has not reactivated within 5 seconds. To recover
communication the Indoor Unit has selected the ‘Default’ RF parameters
and programmed the Outdoor Unit with them.
6.7.2
Packet Error Rate Thresholds
Packet error rate (PER) is calculated as the ratio of the number of uncorrectable
blocks over the number of blocks transmitted per second. Three PER thresholds are
provided for each monitored link, these are:
•
Minor PER Threshold – this threshold defaults to 0.0002 and triggers an alarm
if the calculated PER exceeds this value.
•
Major PER Threshold – this threshold defaults to 0.02 and triggers an alarm if
the calculated PER exceeds this value.
•
Fault PER Threshold – this threshold defaults to 2.0 and triggers an alarm if
the calculated PER exceeds this value.
862-01881 Issue 6
Page 58
MDR5800 User Manual
6.7.2.1
G.826 Thresholds
Three G.826 thresholds are provided for each monitored link. Each of these ratios is
calculated once every second and will trigger a fault condition if the ratios exceed the
programmed thresholds that are:
•
•
•
6.7.2.2
Errored Second Ratio Threshold – this threshold which defaults to 4 X 10-2 triggers
an alarm if the calculated ESR exceeds this value over the measurement period
(Report Time).
Severely Errored Second Ratio Threshold – this threshold which defaults to 2 X 10triggers an alarm if the calculated SESR exceeds this value over the measurement
period (Report Time).
Background Block Error – this threshold which defaults to 6.25 X 10-2 triggers an
alarm if the calculated BBER exceeds this value over the measurement period
(Report Time).
Link Availability
A period of unavailable time begins at the onset of ten consecutive SES events.
These ten seconds are considered to be part of unavailable time. A new period of
available time begins at the onset of ten consecutive non-SES events. These ten
seconds are considered to be part of available time. The figure below illustrates this
definition.
6.7.3
RF Link Error Monitor
The Link Error Monitor screen provides the user with detailed Packet Error Rate
(PER), G.826 and link availability monitoring for the RF link. There is a status field,
Total Seconds, which applies to the link. Total Seconds is the total number of
seconds since the counts were last cleared. It is used to determine available and
unavailable seconds on a link.
6.7.3.1
General
•
Errored Blocks Counter - containing the number of blocks containing errors
accumulated until cleared.
•
Errored Seconds Counter - containing the number of seconds containing
errored blocks since the counters were last cleared.
862-01881 Issue 6
Page 59
MDR5800 User Manual
6.7.3.2
6.7.3.3
•
Severely Errored Seconds Counter - a counter containing the number of
seconds containing more than 30% errored blocks since the counters were last
cleared.
•
Background Block Errors Counter - a counter containing the number of
blocks received in error excluding those contributing to severely errored
seconds since the counters were last cleared.
•
Error Second Ratio – a ratio of the number of Errored seconds to the total
number of seconds since the counters were last reset.
•
Severely Error Second Ratio – a ratio of the number of Severely Errored
seconds to the total number of seconds since the counters were last reset.
•
Background Block Error Ratio – a ratio of the number of Background Blocks
in errors to the total number of blocks received since the counters were last
reset.
•
Corrected Symbols field shows the number of symbols that have been
corrected by the FEC device within the Indoor Unit.
Packet Error Rate
•
Instantaneous Ratio - This is the number of errored blocks as determined by
the FEC on the RF Link, divided by the total number of blocks per second for
that link. If the instantaneous PER exceeds the minor or major PER
thresholds, a fault is triggered and a RF Link error is indicated on the Indoor
Unit Front Panel.
•
Maximised Ratio - The highest Packet error rate reached since the errors were
last cleared.
Link Availability
•
Available Seconds – the number of seconds the link has been available since
counts were last cleared.
•
Unavailable Seconds – the number of seconds the link has been unavailable
since counts were last cleared.
862-01881 Issue 6
Page 60
MDR5800 User Manual
This page is left blank intentionally
862-01881 Issue 6
Page 61
MDR5800 User Manual
7 MAINTENANCE INFORMATION
1. The user is advised to refer to the Technical Data section for details on IU/OU
interconnection cables (customer-furnished).
2. The “Ordering Information” paragraph in the Technical Data section provides details on
part numbers for items that can be ordered.
3. Section 4 of this manual lists customer furnished equipment that should be used for
installing the MDR product.
4. There are two options to control the MDR5800 product via SNMP.
a. One uses any open-standard-compliant SNMP Management package (HP
OpenView, SNMPc etc): in this case, one has access to the full compliment of the
product's MIB elements.
b. The NMS application package supplied with the product accesses a subset of the
MIB. It has a graphical user interface carefully designed to assist installation and
maintenance staff.
862-01881 Issue 6
Page 62
MDR5800 User Manual
This page is left blank intentionally
862-01881 Issue 6
Page 63
MDR5800 User Manual
8 TECHNICAL DATA
8.1
8.1.1
8.1.2
8.2
8.2.1
8.3
8.4
8.5
Environmental Requirements
Outdoor Equipment
Operating temperature:
-30°C to +60°C
Relative humidity:
8-100%
Atmospheric pressure:
0.7 to 1.06 kPa
Lightning protection
ITU-T K.20
Indoor Equipment
Operating temperature:
0°C to +50°C
Relative humidity:
5-90%
Lightning protection:
ITU-T K.20
Mechanical Information for Outdoor Equipment
MDR5800 Outdoor Unit
Dimensions (HxWxD):
335mm x 231mm x 124mm
Weight:
5.9 Kg
Mechanical Information for Indoor Equipment
Dimensions (HxWxD):
45mm x 480 mm x 265mm
Mounting:
19” Rack, 1U high or Table top
Weight:
2.9 Kg
Power Supply Requirements
DC power supply:
21 to 56 VDC
DC power supply grounding:
Positively or negatively grounded
Power consumption:
35 W typical, 45 W maximum.
Electrical Performance
862-01881 Issue 6
Page 64
MDR5800 User Manual
8.5.1
General Characteristics
Frequency Range:
5725 to 5850 MHz
Data Capacity:
E1 (2048 Mbps), T1 (1544 Mbps/s)
2E1 : 2T1
4E1 : 4T1
8.5.2
8.5.2.1
8.5.2.2
RF Channel Bandwidth:
17 MHz
Go/Return spacing:
Can be adjusted as fixed go-return spacing is
NOT mandatory in the ISM licence-free bands.
Modulation:
CCK
Processing Gain:
11 dB
Frequency Channel Plan A:
5735 and 5804 MHz
Frequency Channel Plan B:
5753 and 5822 MHz
Frequency Channel Plan C:
5771 and 5840 MHz
Transmission Delay:
600 us maximum for radios only (one-way)
Transceiver Characteristics
Frequency Band: Lowband Outdoor Units
Transmit band:
5725 – 5787 MHz
Receive band:
5787 – 5850 MHz
Frequency Band: Highband Outdoor Units
Transmit band:
5787 – 5850 MHz
Receive band:
5725 – 5787 MHz
862-01881 Issue 6
Page 65
MDR5800 User Manual
8.5.3
8.5.4
8.5.4.1
8.5.4.2
RF Interface
Transmitted Power
+2 to +24 dBm, software adjustable (incl. mute)
Receiver Sensitivity:
4E1/4T1 : -87dBm for PER = 10-6
Maximum Receive Level:
-30dBm
Payload Data Interfaces
1, 2 or 4 (i.e. nE1) Interface
Data Rate:
Full duplex E1 (2.048Mbit/s), 2E1 or 4E1
Digital Interface:
ITU-T G.703
Connectors:
Balanced 110 ohm on DB25
Line code:
HDB3 or AMI selectable
Jitter and Wander:
ITU-T G.823
1, 2 or 4 (i.e. nT1) Interface
Data Rate:
Full duplex T1 (1.544Mbit/s), 2T1 or 4T1
Digital Interface:
DSX-1, G.703 compliant
Connectors:
Balanced 110 ohm on DB25
Line code:
AMI or B8ZS selectable
Jitter and Wander:
ITU-T G.823
862-01881 Issue 6
Page 66
MDR5800 User Manual
8.5.5
8.5.6
Auxiliary Input Interface (CONTACT CLOSURE)
Number of Inputs:
Maximum voltage:
12V
Logical zero:
Short from input to return pin
Logical one:
Open input to return pin
Auxiliary Output Interface
Number of outputs:
States:
Normally-open and normally-closed
Contact rating:
DC: 220 V, 1 A, 60 W
AC: 250 V, 1 A, 125 VA
8.5.7
8.5.8
8.5.9
Wayside channel interface
Interface standard:
RS232, DCE
Handshaking:
None, Hardware
Port rate:
115,200 bps
Element Manager Port Interface
Interface standard:
RS232, DTE
Handshaking:
Hardware
Data rate:
115,200 bps
Indoor/Outdoor Unit Interface
The physical interface between the Indoor and Outdoor Unit is IEEE802.3 Ethernet.
As such, the same considerations that apply between standard routers/switches/hubs
and PC LAN cards should be adhered to when selecting lengths of cables between the
OU and the IU. Cable lengths of up to 120 meters have been tested in a laboratory
environment.
The following table lists information to assist the user to select cables to be used
between the Indoor and Outdoor Units.
862-01881 Issue 6
Page 67
MDR5800 User Manual
Interconnecting cable
Data
South Africa
STP (FTP) 4 Pairs Solid Cat 5, PVC FR UV protected Polifin
H2/J263/904 Outer Black. Outer diameter of cable : 7.3mm ± 0.5mm.
(this is an “upjacketed” STP 4 Pair cable).
This is a standard FTP
Cat 5 cable that is
‘upjacketed’ with suitable
plastic for FR/UV (Flame
retardant/Ultra Violet)
protection.
Other cables:
1.
2.
3.
4.
Superior Essex BBDN CAT 5 cable P/N 04-0010-34 (7.8mm)
Superior Essex CAT 5 P/N 18-241-31 18-241-11 (5.1mm)
General Cable CAT 5 P/N 2137113 2137114 (5.6mm)
Belden CAT 5 P/N BC1002 (6.0mm)
Option 1 is the preferred choice. For the cables that have diameters
less the required OD, one can use one or two pieces of heatshrink on
the cable where it passes through the gasket.
Interconnecting cable
Power
South Africa
Power 1.5mm sq stranded PVC Insulated, PVC FR UV protected Polifin
H2/J263/904 Outer Black 300/500V Temp -20°C to +85°C. Cable outer
diameter: between 7.4mm and 9mm i.e. 8.2mm ± 0.8mm.
Other cables:
Superior Essex type SJOOW flexible cable P/N 441821* (7.4mm)
Carol Cable (General Cable) SJOW/SJO P/N 02001 18 gauge 2
conductor (7.8mm)
862-01881 Issue 6
Page 68
MDR5800 User Manual
8.6
Ordering Information
Part No
Model Number
Description
651-03853ET1HB
or
651-03853ET1LB
MDR5800-ET1
MDR5800 Radio: Indoor Unit and High or Low Band
Outdoor Unit, Type-N RF output, high power output
for FCC and unregulated, Full E1/T1, 2Mbps or
1.5Mbps data interface
651-03853ET2HB
or
651-03853ET2LB
MDR5800-ET2
MDR5800 Radio: Indoor Unit and High or Low band
Outdoor Unit, Type-N RF output, high power output
for FCC and unregulated, Full 2xE1/2xT1, 2x2Mbps
or 2x1.5Mbps data interface
651-03853ET4HB
or
651-03853ET4LB
MDR5800-ET4
MDR5800 Radio: Indoor Unit and High or Low band
Outdoor Unit, Type-N RF output, high power output
for FCC and unregulated, Full 4xE1/4xT1, 4x2Mbps
or 4x1.5Mbps data interface
MDR5800 operates from 21-56VDC, optional 110-220VAC power supply available below.
A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB).
Accessories & Upgrades
Part Number
Description
651-03864
Bench Power Supply 110-220VAC to 48VDC
651-03865
MDR 5800 Upgrade 1xE1/T1 to 2xE1/T1
651-03866
MDR 5800 Upgrade 2xE1/T1 to 4xE1/T1
651-03867
MDR 5800 Upgrade 1xE1/T1 to 4xE1/T1
The MDR5800 uses standard CAT5 Ethernet cable and RJ-45 connectors for connecting the
Indoor Unit to the Outdoor Unit. A two-wire power cable is also required between the Indoor Unit
and the Outdoor Unit. Note Screened Cat5 cable and UV resistant cables are recommended for
long term outdoor use.
862-01881 Issue 6
Page 69
MDR5800 User Manual
Microwave Digital Radio System Spare Parts for MDR5800
Part Number
Description
651-03810ET1
MDR5800 Indoor Unit 1xE1/T1 - Spare Part
651-03810ET2
MDR5800 Indoor Unit 2xE1/T1 - Spare Part
651-03810ET4
MDR5800 Indoor Unit 4xE1/T1 - Spare Part
651-03806LB
MDR5800 Low Band Outdoor Unit - Spare Part
651-03806HB
MDR5800 High Band Outdoor Unit - Spare Part
651-03868
MDR5800 NMS Software Disk - Spare Part
651-03809
MDR5800 ODU Pole Mounting Kit - Spare Part
862-01881
MDR5800 Digital Radio System User Manual - Spare Part
660-03405
MDR5800 Cable Assembly: RSSI Test Loom - Spare Part
862-01881 Issue 6
Page 70
MDR5800 User Manual
MDR5800 Ordering Information:
Part no’s:
1E1/T1 Radio: 651-03853ET1HB or 651-03853ET1LB
2E1/T1 Radio: 651-03853ET2HB or 651-03853ET2LB
4E1/T1 Radio: 651-03853ET4HB or 651-03853ET4LB
Each MDR5800 radio includes the following:
Part No
651-03810ET1 or
Description
QTY
MDR5800 Indoor Unit: 1xE1/T1or 2xE1/T1 or 4xE1/T1
MDR5800 Outdoor unit
651-03809
MDR 5800 ODU Pole Mounting Kit
862-01881
MDR5800 Digital Radio System User Manual
651-03868
NMS Software Disks
660-03405
RSSI Cable
651-03810ET2 or
651-03810ET4
651-03806HB
or
651-03806LB
It is possible to purchase upgrades for E1/T1 Indoor Units (upgrades to 2E1/T1 or
4E1/T1). The user contacts the factory and provides the Indoor Unit Bar Code
number details. The factory then supplies a “Tributary Code”, unique to the Indoor
Unit, which is entered using the MIB (Version 1 & 2 product) or using the NMS
(Version 2 product).
862-01881 Issue 6
Page 71
MDR5800 User Manual
9 APPENDIX A: ELEMENT MANAGER PORT POINT-TO-POINT
SERIAL COMMUNICATIONS SETUP
This appendix summarises how to set up a network connection (using PPP) between a computer and the
MDR5800 Indoor Unit’s Element Manager port. It lists how the connection can be setup and configured
to allow data transfer and SNMP-based control of the MDR5800 Indoor Unit.
Note : For both NT and Win 95 or 98 machines, check that a
Network Adapter is installed.
The following screen capture shows the Windows help available to assist setting up a
serial comms network adapter.
862-01881 Issue 6
Page 72
MDR5800 User Manual
9.1
Adding a Modem : Windows NT
1. When working with a PC running a Windows NT, add a modem using the
following screen as a guideline.
862-01881 Issue 6
Page 73
MDR5800 User Manual
862-01881 Issue 6
Page 74
MDR5800 User Manual
2. Select the COM port to use – push the Next when the COM port has been selected.
862-01881 Issue 6
Page 75
MDR5800 User Manual
862-01881 Issue 6
Page 76
MDR5800 User Manual
9.2
Adding Dial-up Networking : Windows NT
9.2.1
To add dial-up networking
1. From the desktop, open the My Computer icon and double-click the Dial-up
Networking icon.
2. The following windows are displayed:
862-01881 Issue 6
Page 77
MDR5800 User Manual
3. Whether COM1 or COM2 is selected, setup the connection using the following screens as
a guideline. This allows establishment of a PPP connection between the computer and
the MDR5800 Indoor Unit’s Element Manager port.
862-01881 Issue 6
Page 78
MDR5800 User Manual
862-01881 Issue 6
Page 79
MDR5800 User Manual
862-01881 Issue 6
Page 80
MDR5800 User Manual
862-01881 Issue 6
Page 81
MDR5800 User Manual
9.3
Adding a Modem : Windows 95/98
1. When working with a PC running a Windows 95/98, add a modem using the
following screen as a guideline.
862-01881 Issue 6
Page 82
MDR5800 User Manual
3. Use the mdmnull.inf to add a serial cable modem connection capability to the PC or
laptop.
4. Once setup, use the following screens to set up the COM port’s parameters.
862-01881 Issue 6
Page 83
MDR5800 User Manual
862-01881 Issue 6
Page 84
MDR5800 User Manual
9.4
Adding Dial-up Networking : Windows 95/98
1. After adding the modem, set up the connection properties using the following screens as a
guideline. This will allow establishment of a PPP connection between the computer and
the MDR5800 Indoor Unit’s Element Manager port. A Null_Modem connection option as
shown below will be created. If one doesn’t exist, double click on the “Make New
862-01881 Issue 6
Page 85
MDR5800 User Manual
862-01881 Issue 6
Page 86
MDR5800 User Manual
10 APPENDIX B: MANAGEMENT OF THE MDR5800
All management of the MDR product is implemented using SNMP (Simple Network Management
Protocol), an open standard. The MDR5800 product can be managed by:
1. Standard SNMP managers such as HP OpenView or SNMPc i.e. there is Open Network
Management compatibility.
2. For rapid product installation, the NMS GUI Application (hereafter referred to as the NMSGA) provides extensive management functions on site and, via the microwave radio link,
can be used to access the MDR station on the opposite side of the link. The MDR5800
NMS-GA is a software application that runs on a PC workstation such as a laptop or
notebook computer that is connected to an MDR 5800 Indoor Unit (IU) serial port (DB9
DTE) or an Ethernet connection (10BaseT DTE) (both accessed via the IU front-panel).
10.1
SNMP and the MDR5800
Use of SNMP within the product allows remote: configuration, monitoring of performance,
notification of alarms and firmware upgrades via an IP-network. Within an IP network supporting
routing of IP data, the radios can be supported from any remote location. The product can be
accessed via the Internet if the necessary gateways are provided. A GSM/PCS modem dial-up
capability provides another remote management option.
The MDR Indoor Units have built-in SNMP agents and an extensive MIB (Management
Information Base). The MDR5800 product uses SNMP V1 (RFC1155, 1157). The user has access
to an Enterprise MIB (obtainable though customer services) and MIB II (RFC 1213).
Access to the MIB via the IU SNMP agent is via Ethernet (10BaseT interface on the product's front
panel) or PPP (RFC 1661) via the product's serial channel Element Manager port. The use of
SNMP provides flexibility for operators with central equipment monitoring. It provides
management access to radio configuration (all data interfaces), interface status and statistics, fault
and maintenance information.
SNMP security (if enabled) is ensured by using a login and password to give the user administrator
or basic user rights (a standard user rights option limits the ability to SET MIB variables).
The product has threshold-based alarm generation (there is an extensive SNMP trap list with a
trap filter that is adjustable via SNMP). Network access (wired or wireless i.e. GSM/PCS Modem)
allows over-the-air remote firmware uploading (FTP) with a load verification (and reversion)
capability.
862-01881 Issue 6
Page 87
MDR5800 User Manual
There are three principle requirements to use SNMP with the MDR5800 Radio Stations.
1. A Management Station that runs a SNMP Management Software package that is installed
on a networked or stand-alone PC that can be connected to an Indoor Unit either using a
serial connection or an Ethernet connection. From the Management station, the agents
within the MDR Indoor Units can be configured or polled for information.
2. Agent: The agent accepts SNMP GET, SET or GET-NEXT commands from the
Management Application software and collects or adjusts information from the Indoor
Unit's MIB.
3. Management Information Base (MIB): the MIB is a database that is accessed based on the
OID (object ID) the SNMP Manager has chosen. The MDR Indoor Unit used an Enterprise
MIB and a standard MIB (MIB II) to store or allow access to information relevant to the
MDR Link.
862-01881 Issue 6
Page 88
MD
10.2
The MIB Elements – OID (Object ID) DESCRIPTIONS
Object ID
Group
Object Type
Iso
1.3
Org
1.3.6
dod
1.3.6.1
internet
1.3.6.1.4
private
1.3.6.1.4.1
enterprises
1.3.6.1.4.1.1316
plessey
1.3.6.1.4.1.1316.1
products
1.3.6.1.4.1.1316.1.1
digitalradio
1.3.6.1.4.1.1316.1.1.1
mdrmte
1.3.6.1.4.1.1316.1.1.1.1
mdrmtePerformance
1.3.6.1.4.1.1316.1.1.1.1.1
mdrmtePayloadPerf
1.3.6.1.4.1.1316.1.1.1.1.1.1
mdrmtePpTable
SEQUENCE
1.3.6.1.4.1.1316.1.1.1.1.1.1.1
mdrmtePpEntry
SYNTAX
Access
Description
1.3.6.1.4.1.1316.1.1.1.1.1.1.1.1 mdrmtePpIndex
INTEGER
1.3.6.1.4.1.1316.1.1.1.1.1.1.1.2 mdrmtePpLOS
INTEGER
read-only
A Loss of Signal has been detected on
the input to a tributary - there are four,
one for each tributary.
1.3.6.1.4.1.1316.1.1.1.1.1.1.1.3 mdrmtePpAIS
INTEGER
read-only
An Alarm Indication Signal has been
detected on the input to a tributary there are four, one for each tributary.
1.3.6.1.4.1.1316.1.1.1.1.2
mdrmteRFLinkPerf
1.3.6.1.4.1.1316.1.1.1.1.2.1
mdrmteCarrierDetect
INTEGER
read-only
Indicates if a RF Carrier has been
detected by Outdoor Unit – if so, the
header in the RF Packet has been
identified as a potential valid packet note however, that it could be received
from another transmitter that uses the
same header format.
1.3.6.1.4.1.1316.1.1.1.1.2.2
MdrmteRSSI †2
Gauge
read-only
A dBm value representative of the
received signal level. The value
detected is representative of the level
that would be measured should a CW
signal be input at the Outdoor Unit's
Diplexer RF Port - a Spread Spectrum
signal will appear to be 20 dB lower.
1.3.6.1.4.1.1316.1.1.1.1.2.3
mdrmteCurrentPER
DisplayString
read-only
This is the current Packet Error Rate
and is based on the number of
† indicates Version 2.0 MIB additions/name changes
862-01881 Issue 6
MD
Object ID
Group
Object Type
Access
Description
uncorrectable packets/blocks being
detected by the FEC (Forward Error
Correction) circuitry within the Indoor
Unit (based on the number of errored
packets divided by the total number of
packets transmitted in a measurement
period of 250msec).
1.3.6.1.4.1.1316.1.1.1.1.2.4
mdrmteMaximizedPER
DisplayString
read-only
This is the maximum Packet Error
Rate detected during the last
measurement period, based number
of maximum number of uncorrectable
packets/blocks detected by the FEC
circuitry within the Indoor Unit.
1.3.6.1.4.1.1316.1.1.1.1.2.5
mdrmteLinkUnavailable
INTEGER
read-only
Based on G.826 criteria, this MIB
element indicates RF Link
Availability/Non-availability.
1.3.6.1.4.1.1316.1.1.1.1.2.6
mdrmteFrameUnlock
INTEGER
read-only
The data that is transmitted across
the RF Link is conveyed in a frame,
compiled within the Indoor Unit's
FPGA. The received data frame is
examined to see that the frame, with a
suitable format has been received.
1.3.6.1.4.1.1316.1.1.1.1.2.7
mdrmteReserved1
Gauge
1.3.6.1.4.1.1316.1.1.1.1.2.8
mdrmteErrSecRatioExceeded
INTEGER
read-only
The ESR is a ratio of the number of
Errored seconds (one second periods
within which uncorrectable packets
were counted by the FEC IC) to the
total time in seconds.
1.3.6.1.4.1.1316.1.1.1.1.2.9
mdrmteSevErrSecRatioExceeded
INTEGER
read-only
The SESR is a ratio of the number of
Severely Errored seconds (one
second periods within which 30% of
packets over the RF Link had
uncorrectable errors) to the total time
in seconds.
1.3.6.1.4.1.1316.1.1.1.1.2.10
mdrmteBkgrndBlkErrRatioExceeded
INTEGER
read-only
The BBER is a ratio of the number of
uncorrectable blocks/packets received
to the total number of packets
received.
1.3.6.1.4.1.1316.1.1.1.1.2.11
mdrmteMinorPERExceeded
INTEGER
read-only
This parameter indicates if the minor
packet (uncorrectable by FEC) error
rate has been exceeded based on the
defined threshold listed in the
mdrmteFAULT mdrmtePerfTrapThreshold group. A
GH filter is applied to the calculation.
This GH filter functions as a weighted
average where the GH Average Filter
Fraction is the proportion of the
instantaneous PER used in the current
seconds calculation. The remainder
(1-Fraction(0.7)) is taken from the
previous 250 milli-second calculation.
1.3.6.1.4.1.1316.1.1.1.1.2.12
mdrmteMajorPERExceeded
INTEGER
read-only
This parameter indicates if the major
862-01881 Issue 6
Reserved.
MD
Object ID
Group
Object Type
Access
Description
packet (uncorrectable by FEC) error
rate has been exceeded based on the
defined threshold listed in the
mdrmteFAULT mdrmtePerfTrapThreshold group.
1.3.6.1.4.1.1316.1.1.1.1.2.13
mdrmteCriticalPERExceeded
INTEGER
read-only
This parameter indicates if the critical
packet (uncorrectable by FEC) error
rate has been exceeded based on the
defined threshold listed in the
mdrmteFAULT mdrmtePerfTrapThreshold group.
1.3.6.1.4.1.1316.1.1.1.1.2.14
mdrmtePrevParamsRestored
INTEGER
read-only
Indicates if “auto recovery” for the
Outdoor Unit settings had to be
invoked due to an unsuitable choice of
frequency or power settings for the RF
link.
1.3.6.1.4.1.1316.1.1.1.1.2.15
mdrmteResetAllRFLinkPerf
INTEGER
write-only
Reset performance-monitoring
parameters associated with the MIB
mdrmteRFLinkPerf group.
1.3.6.1.4.1.1316.1.1.1.1.3
mdrmteG826
1.3.6.1.4.1.1316.1.1.1.1.3.1
mdrmteStatus
INTEGER
read-only
Indicates if 'G.826-like' errored,
severely errored and unavailable
conditions have been monitored on
the RF Link.
1.3.6.1.4.1.1316.1.1.1.1.3.2
mdrmteTotalSeconds
Counter
read-only
Indicates the total number of seconds,
both available and unavailable.
1.3.6.1.4.1.1316.1.1.1.1.3.3
mdrmteAvailableSeconds
Counter
read-only
A period of unavailable time begins at
the onset of ten consecutive SES
events. These ten seconds are
considered to be part of unavailable
time. A new period of available time
begins at the onset of ten consecutive
non-SES events. These ten seconds
are considered to be part of available
time.
1.3.6.1.4.1.1316.1.1.1.1.3.4
mdrmteUnavailableSeconds
Counter
read-only
A period of unavailable time begins at
the onset of ten consecutive SES
events. These ten seconds are
considered to be part of unavailable
time. A new period of available time
begins at the onset of ten consecutive
non-SES events. These ten seconds
are considered to be part of available
time.
1.3.6.1.4.1.1316.1.1.1.1.3.5
mdrmteErroredSeconds
Counter
read-only
A one second period with one or more
errored packets (uncorrectable
packets) or at least one defect.
1.3.6.1.4.1.1316.1.1.1.1.3.6
mdrmteSeverelyErroredSeconds
Counter
read-only
A one-second period which contains >
30% errored blocks or at least one
defect. SES is a subset of ES.
1.3.6.1.4.1.1316.1.1.1.1.3.7
mdrmteErroredBlocks
Counter
read-only
A packet that has been identified as
containing uncorrectable bits by the
862-01881 Issue 6
MD
Object ID
Group
Object Type
Access
Description
FEC circuitry.
1.3.6.1.4.1.1316.1.1.1.1.3.8
mdrmteBackgroundBlockErrors
Counter
read-only
An errored block not occurring as part
of a SES.
mdrmteErroredSecondsRatio
DisplayString
read-only
The ratio of ES to total seconds in
available time during a fixed
measurement interval.
1.3.6.1.4.1.1316.1.1.1.1.3.10
mdrmteSeverelyErroredSecondsRatio
DisplayString
read-only
The ratio of SES to total seconds in
available time during a fixed
measurement interval.
1.3.6.1.4.1.1316.1.1.1.1.3.11
mdrmteBackgroundBlockErrorRatio
DisplayString
read-only
The ratio of Background Block Errors
(BBE) to total blocks in the available
time during a fixed measurement
interval. The count of total blocks
excludes all blocks during SESs.
1.3.6.1.4.1.1316.1.1.1.1.3.12
mdrmteResetAllG826
INTEGER
write-only
Reset all parameters associated with
G.826 measurements for the RF Link
1.3.6.1.4.1.1316.1.1.1.1.3.13
mdrmteCorrectedSymbols
INTEGER
read-only
This parameter lists the number of
corrected symbols i.e. those corrected
by the FEC.
1.3.6.1.4.1.1316.1.1.1.1.4
mdrmteResetAllPerfData
INTEGER
write-only
Reset all parameters associated with
Packet Error and G.826
measurements for the RF Link.
1.3.6.1.4.1.1316.1.1.1.2
mdrmteConfiguration
1.3.6.1.4.1.1316.1.1.1.2.1
MdrmtePayloadConf
1.3.6.1.4.1.1316.1.1.1.2.1.1
MdrmteDataRate
INTEGER
read-write Configure the tributary data interface
rate - either E1 or T1.
1.3.6.1.4.1.1316.1.1.1.2.1.2
mdrmteLineCodeType
INTEGER
read-write Defines the line code types for the
tributaries, either HDB3 or AMI for E1
tributaries or B8ZS or AMI for T1
tributaries.
1.3.6.1.4.1.1316.1.1.1.2.1.3
mdrmtePcTable
SEQUENCE
1.3.6.1.4.1.1316.1.1.1.2.1.3.1
mdrmtePcEntry
SYNTAX
1.3.6.1.4.1.1316.1.1.1.1.3.9
1.3.6.1.4.1.1316.1.1.1.2.1.3.1.1 mdrmtePcIndex
INTEGER
1.3.6.1.4.1.1316.1.1.1.2.1.3.1.2 mdrmtePcLabel
DisplayString
read-write E1/T1 Payload configuration tributary
label.
1.3.6.1.4.1.1316.1.1.1.2.1.3.1.3 mdrmtePcActive
INTEGER
read-write Defines whether tributaries are active
or inactive.
1.3.6.1.4.1.1316.1.1.1.2.2
mdrmteRFLinkConf
1.3.6.1.4.1.1316.1.1.1.2.2.1
mdrmteTxPower
INTEGER
read-write Allows setup of the output power
available at the diplexer port of the
Outdoor Unit.
1.3.6.1.4.1.1316.1.1.1.2.2.2
mdrmteBandPlan
INTEGER
read-write The MDR5800 Outdoor Units operate
in the 5.725 GHz to 5.850 GHz ISM
frequency band. The MDR5800 has
predefined frequency channel plans
(termed A, B, C and D). Refer to the
User's manual for details on defined
frequencies.
862-01881 Issue 6
MD
Object ID
Group
Object Type
Access
1.3.6.1.4.1.1316.1.1.1.2.2.3
mdrmteTxFrequencyPlanD
INTEGER
read-write Frequency plan D allows independent
control of transmit and receive
frequencies. This enables a very
flexible frequency plan and can be
used to overcome interference in the
5.8 GHz ISM band. The frequencies
that can be used in the lower or upper
sub-bands can be selected in 1 MHz
increments. Performance
degradation can be expected when
operating using channel plan D mode
and the chosen frequencies are close
to the sub-band edges i.e. a choice of
one of the high frequencies in the
lower sub-band and one of the lower
frequencies in the upper sub-band.
The allocation of Channel plan D
frequencies is Lower Sub-band 5735-5771 MHz, Upper Sub-band 5804-5840 MHz. The user must take
note of whether the radio is a high or
low band unit before choosing a set of
transmit and receive frequencies.
Note also that THE TX AND RX
FREQUENCIES MUST BE
SELECTED BEFORE BAND PLAN D
OPTION IS SELECTED VIA THE MIB.
1.3.6.1.4.1.1316.1.1.1.2.2.4
mdrmteRxFrequencyPlanD
INTEGER
read-write Refer to the
mdrmteTxFrequencyPlanD
description.
1.3.6.1.4.1.1316.1.1.1.2.2.5
mdrmteTransmitBand
INTEGER
read-only
1.3.6.1.4.1.1316.1.1.1.2.2.6
MdrmteReserved2
INTEGER
1.3.6.1.4.1.1316.1.1.1.2.2.7
mdrmteRegulations
INTEGER
1.3.6.1.4.1.1316.1.1.1.2.2.8
mdrmteAutoRecovery
INTEGER
862-01881 Issue 6
Description
This value is read from the Outdoor
Unit via the Indoor Unit and defines
whether it transmits in the Lower Subband - 5735-5771 MHz or Upper Subband - 5804-5840 MHz.
This parameter is read from the
Outdoor Unit via the Indoor Unit and
defines regulatory compliance of the
Outdoor Unit.
read-only
This feature is used if the user is
installing a link from one side and
there is no assistance on the opposite
side of the link. It mitigates against
the link failing and not being able to
be re-established. If “auto recovery” is
enabled, the required operational RF
parameters are programmed into the
Outdoor Units by the local and remote
Indoor Units. If communication
between the two Indoor Units has not
reactivated within 5 seconds, the
previous (working) 'default' RF
parameters are programmed into the
respective Outdoor Units.
MD
Object ID
Group
Object Type
Access
1.3.6.1.4.1.1316.1.1.1.2.2.9
mdrmteOURateOverride
INTEGER
read-write Deprecated
1.3.6.1.4.1.1316.1.1.1.2.2.10
mdrmteOUDataRate
INTEGER
read-write A settable rate that allows a reduced
transfer data rate over the RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.11
mdrmteTxFrequencyCurrent
INTEGER
read-only
This value [MHz] is read back from
the Outdoor Unit and defines the
transmit frequency of the Outdoor
Unit.
1.3.6.1.4.1.1316.1.1.1.2.2.12
mdrmteRxFrequencyCurrent
INTEGER
read-only
This value [MHz] is read back from
the Outdoor Unit and defines the
receive frequency of the Outdoor Unit.
1.3.6.1.4.1.1316.1.1.1.2.2.13
mdrmteNonAutoBandPlan
INTEGER
read-write Same as mdrMTEBandPlan setting in
this MIB group except “auto recovery”
is not enabled - this allows control of
the Outdoor Unit frequencies without
the “auto recovery” feature attempting
to intervene and re-establish setup of
an operational RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.14
mdrmteNonAutoTxFreqPlanD
INTEGER
read-write Same as mdrTxFrequencyPlanD
setting in this MIB group except “auto
recovery” is not enabled - this allows
control of the Outdoor Unit Plan D
frequencies without the “auto
recovery” feature attempting to
intervene and re-establish setup of an
operational RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.15
mdrmteNonAutoRxFreqPlanD
INTEGER
read-write Same as mdrTxFrequencyPlanD
setting in this MIB group except “auto
recovery” is not enabled - this allows
control of the Outdoor Unit Plan D
frequencies without the “auto
recovery” feature attempting to
intervene and re-establish setup of an
operational RF Link.
1.3.6.1.4.1.1316.1.1.1.2.2.16
mdrmteNonAutoTxPower
INTEGER
read-write Same as mdrTxPower setting in this
MIB group except “auto recovery” is
not enabled - this allows control of the
Outdoor Unit power level setting
without the “auto recovery” feature
attempting to intervene and reestablish setup of an operational RF
Link.
1.3.6.1.4.1.1316.1.1.1.2.3
mdrmteServiceChannel
1.3.6.1.4.1.1316.1.1.1.2.3.1
mdrmteScDataRate†3
INTEGER
read-write Bit rate used across the wayside
service channel link.
1.3.6.1.4.1.1316.1.1.1.2.3.2
mdrmteScDataBits†
INTEGER
read-write The data width - can be 7 or 8 bits.
1.3.6.1.4.1.1316.1.1.1.2.3.3
MdrmteScParity
INTEGER
read-write Serial channel - set to none, odd or
even.
Fixed at 115.2kbps in Version 1.0 and 2.0 IU firmware releases.
Serial setting – 8 bits, no parity, 1 stop bit
862-01881 Issue 6
Description
MD
Object ID
Group
Object Type
Access
1.3.6.1.4.1.1316.1.1.1.2.3.4
MdrmteScStopBits
INTEGER
read-write The number of stop bits can be set to
1 or 2.
1.3.6.1.4.1.1316.1.1.1.2.3.5
mdrmteScFlowControl
INTEGER
read-write Either hardware or no flow control is
used.
1.3.6.1.4.1.1316.1.1.1.2.3.6
mdrmteScStatusDump
INTEGER
read-write Allows the wayside service (serial)
channel to be used as a diagnostics
port [deprecated].
1.3.6.1.4.1.1316.1.1.1.2.4
MdrmteGeneral
1.3.6.1.4.1.1316.1.1.1.2.4.1
MdrmteStationName
DisplayString
read-write The station name is stored in the
Indoor Unit in non-volatile memory limited to 14 characters in length.
1.3.6.1.4.1.1316.1.1.1.2.4.2
mdrmteIUSerialNumber
DisplayString
read-only
An electronic serial number is read
from the Indoor Unit - this number is
unique for each IU and is derived from
an IC that is used within the product.
1.3.6.1.4.1.1316.1.1.1.2.4.3
mdrmteIUFirmwareVersion
DisplayString
read-only
The Indoor Unit firmware version is
the version of application firmware
that loaded into the product's
application Flash.
1.3.6.1.4.1.1316.1.1.1.2.4.4
mdrmteIUBootkernelVersion
DisplayString
read-only
The Indoor Unit bootkernel version is
the version of boot firmware that
loaded into the product's Boot Flash.
1.3.6.1.4.1.1316.1.1.1.2.4.5
mdrmteOUSerialNumber
INTEGER
read-only
The Outdoor Serial Number is
programmed into the OU at time of
manufacture and is read via the
Indoor Unit.
1.3.6.1.4.1.1316.1.1.1.2.4.6
MdrmteOUPICFirmwareVersion
DisplayString
read-only
The Outdoor Unit PIC firmware
number is programmed into the OU at
time of manufacture and is read via
the Indoor Unit.
1.3.6.1.4.1.1316.1.1.1.2.4.7
mdrmteOUPayloadSupport
INTEGER
1.3.6.1.4.1.1316.1.1.1.2.4.8
mdrmteDate
DisplayString
read-write This is a date record that is recovered
from the Indoor Unit's Real Time
Clock.
1.3.6.1.4.1.1316.1.1.1.2.4.9
mdrmteTime
DisplayString
read-write This is a time record that is recovered
from the Indoor Unit's Real Time
Clock.
1.3.6.1.4.1.1316.1.1.1.2.4.10
mdrmteNOVRAMInit
INTEGER
read-write If activated, the Nonvolatile memory is
initialised to a set of default
parameters.
1.3.6.1.4.1.1316.1.1.1.2.4.11
mdrmteFECBypass
INTEGER
read-write This is primarily a laboratory test entry
used to control whether the FEC
circuitry within the Indoor Unit is
activated. By default the FEC is not
bypassed i.e. FEC is active.
1.3.6.1.4.1.1316.1.1.1.2.4.12
mdrmteFECCorrectableSymbols
INTEGER
read-write This is primarily a laboratory test entry
used to control the FEC correction
power - 20 parity symbols are
appended to the transmit packet - 10
is the maximum number of symbols
862-01881 Issue 6
Description
Deprecated.
MD
Object ID
Group
Object Type
Access
1.3.6.1.4.1.1316.1.1.1.2.4.13
mdrmteTribCode
DisplayString
read-write This is a text entry code (16
characters) used to allow activation of
tributaries on the Indoor Units. It is
unique to the Indoor Unit based on a
hardware-dependent serial number in
the IU.
1.3.6.1.4.1.1316.1.1.1.2.4.14
mdrmteIndoorUnitBarCodeNumber†
DisplayString
read-write This is a text entry code used to allow
storage of the Indoor Unit's bar code
serial number (as seen on the outside
of the on the outside of product's
housing).
1.3.6.1.4.1.1316.1.1.1.2.5
mdrmteFirmware
1.3.6.1.4.1.1316.1.1.1.2.5.1
mdrmteFTPServerStatus†
INTEGER
read-write This allows activation/deactivation of
the FTP server that runs in the Indoor
Unit and is used to upload new
revisions of firmware via a routed IP
network.
1.3.6.1.4.1.1316.1.1.1.2.5.2
mdrmteFlashNewFirmware†
INTEGER
read-write This entry determines the time when
the new version of firmware will be
activated.
1.3.6.1.4.1.1316.1.1.1.3
mdrmteFault
1.3.6.1.4.1.1316.1.1.1.3.1
mdrmteInfo
1.3.6.1.4.1.1316.1.1.1.3.1.1
mdrmteLEDTable
SEQUENCE
A group of LEDs on the front panel of
the Indoor Unit.
1.3.6.1.4.1.1316.1.1.1.3.1.1.1
mdrmteLEDEntry
SYNTAX
A LED entry containing objects
describing a particular LED.
1.3.6.1.4.1.1316.1.1.1.3.1.1.1.1 mdrmteLEDIndex
INTEGER
A unique value for each LED in the
Indoor Unit. Its value ranges from 1
to the number of LEDs on the front
panel of the Indoor Unit.
1.3.6.1.4.1.1316.1.1.1.3.1.1.1.2 mdrmteLEDLabel
DisplayString
read-only
SYSTEM Green OK, Orange (OU/IU
Comms Error), Red (OU/IU Comms
Down) PAYLOAD Green OK, Orange
(AIS Detected), Red (LOS
Detected)RF LINK Green OK, Orange
(FEC Correcting Errors), Red (FEC
unable to correct errors)In ALL cases
flashing red and orange LEDs imply
historic alarm conditions (The alarm
can be cleared using the front panel
button 'position 1': see next
paragraph).
1.3.6.1.4.1.1316.1.1.1.3.1.1.1.3 mdrmteLEDState
INTEGER
read-only
The current state of the LED - for a
detailed description of functionality,
see the mdrmteLEDLabel entry.
862-01881 Issue 6
Description
the FEC circuitry can correct. At a
maximum, 20 symbols in error can be
detected but only 10 can be corrected
- the higher the correction power
selected, the greater the improvement
in system gain.
MD
Object ID
Object Type
Access
Description
1.3.6.1.4.1.1316.1.1.1.3.1.1.1.4 mdrmteLEDColour
INTEGER
read-only
The current colour of the LED - for a
detailed description of functionality,
see the mdrmteLEDLabel entry.
1.3.6.1.4.1.1316.1.1.1.3.1.2
mdrmteOutdoorUnitComms
INTEGER
read-only
Describes the state of communication
with the Outdoor unit in terms of
whether it is up or down completely.
Alternatively, if there were errors,
these are identified as comms errors
(based on a CRC check) or content
errors (i.e. undeclared, unused
messages).
1.3.6.1.4.1.1316.1.1.1.3.1.3
mdrmteOutdoorUnitResetType
INTEGER
read-only
This message is read from the
Outdoor Unit and identifies the last
reason for a reset within the OU.
1.3.6.1.4.1.1316.1.1.1.3.1.4
mdrmteOutdoorUnitLockDetect
INTEGER
read-only
The transmit RF synthesizer, receive
RF synthesizer and IF phased locked
loop lock detect signals are monitored
and reported via this MIB element.
1.3.6.1.4.1.1316.1.1.1.3.2
mdrmteSelfTest
1.3.6.1.4.1.1316.1.1.1.3.2.1
mdrmteFlash
INTEGER
read-only
Identifies pass/fail status of the Indoor
Unit's application flash.
1.3.6.1.4.1.1316.1.1.1.3.2.2
mdrmteDRAM
INTEGER
read-only
Identifies pass/fail status of the Indoor
Unit's Dynamic RAM.
1.3.6.1.4.1.1316.1.1.1.3.2.3
mdrmteSRAM
INTEGER
read-only
Identifies pass/fail status of the Indoor
Unit's Static RAM.
1.3.6.1.4.1.1316.1.1.1.3.2.4
mdrmteLineInterface
INTEGER
read-only
Identifies pass/fail status of the Indoor
Unit's Line Interface IC.
1.3.6.1.4.1.1316.1.1.1.3.2.5
mdrmteFPGA
INTEGER
read-only
Identifies pass/fail status of the Indoor
Unit's FPGA interface registers to the
microprocessor.
1.3.6.1.4.1.1316.1.1.1.3.2.6
mdrmteFEC
INTEGER
read-only
Identifies pass/fail status of the Indoor
Unit's FEC IC electrical interface.
1.3.6.1.4.1.1316.1.1.1.3.2.7
mdrmteRealTimeClock
INTEGER
read-only
Identifies pass/fail status of the Indoor
Unit's Real Time Clock.
1.3.6.1.4.1.1316.1.1.1.3.2.8
mdrmteIndoorUnitResetType
INTEGER
read-only
This message is read from the Indoor
Unit and identifies the last reason for
a reset within the IU.
1.3.6.1.4.1.1316.1.1.1.3.2.9
mdrmteLoopbackMode
INTEGER
read-write Entry defines the loopback mode of a
radio station in terms of loopback at
either the payload line interface level,
baseband processor level in an OU or
RF loopback in the OU.
1.3.6.1.4.1.1316.1.1.1.3.2.10
mdrmteLoopbackTimeOut
INTEGER
read-write This is the number of seconds the
loopback will run for until it times out.
1.3.6.1.4.1.1316.1.1.1.3.3
mdrmteTrapManagement
1.3.6.1.4.1.1316.1.1.1.3.3.1
mdrmteTrapFilter
INTEGER
read-write Alarms within the MDR product are
classified as critical, major, minor or
informational. The trap filter allows
screening of alarms before they are
862-01881 Issue 6
Group
MD
Object ID
Group
Object Type
Access
Description
dispatched as traps.
1.3.6.1.4.1.1316.1.1.1.3.3.2
mdrmteNumberTrapManagers
INTEGER
read-only
This entry shows the number of trap
managers allowed.
1.3.6.1.4.1.1316.1.1.1.3.3.3
mdrmteTrapManagerTable
SEQUENCE
1.3.6.1.4.1.1316.1.1.1.3.3.3.1
mdrmteTrapManagerEntry
SYNTAX
1.3.6.1.4.1.1316.1.1.1.3.3.3.1.1 mdrmteTrapManagerIndex
INTEGER
1.3.6.1.4.1.1316.1.1.1.3.3.3.1.2 mdrmteTrapManagerIP
IpAddress
read-write This is the IP address of the
management station that is set up to
detect and act upon received traps.
1.3.6.1.4.1.1316.1.1.1.3.3.3.1.3 mdrmteTrapManagerComm
DisplayString
read-write This is the “SNMP community name”
used for dispatch of traps.
1.3.6.1.4.1.1316.1.1.1.3.3.3.1.4 mdrmteTrapManagerActive
INTEGER
read-write Defines whether a particular Trap
Manager is active or inactive.
1.3.6.1.4.1.1316.1.1.1.3.4
mdrmtePerfTrapThreshold
1.3.6.1.4.1.1316.1.1.1.3.4.1
mdrmteMinorPERThreshold
DisplayString
read-write Defines the threshold used as a
checking criterion for the Minor PER
(Packet Error Rate).
1.3.6.1.4.1.1316.1.1.1.3.4.2
mdrmteMajorPERThreshold
DisplayString
read-write Defines the threshold used as a
checking criterion for the Major PER
(Packet Error Rate).
1.3.6.1.4.1.1316.1.1.1.3.4.3
mdrmteCriticalPERThreshold
DisplayString
read-write Defines the threshold used as a
checking criterion for the Critical PER
(Packet Error Rate).
1.3.6.1.4.1.1316.1.1.1.3.4.4
mdrmteErrSecRatioThreshold
DisplayString
read-write Defines the threshold used as a
checking criterion for the Errored
Second Ratio.
1.3.6.1.4.1.1316.1.1.1.3.4.5
mdrmteSevErrSecRatioThreshold
DisplayString
read-write Defines the threshold used as a
checking criterion for the Severely
Errored Second Ratio.
1.3.6.1.4.1.1316.1.1.1.3.4.6
mdrmteBkgrndBlkErrRatioThreshold
DisplayString
read-write Defines the threshold used as a
checking criterion for the Background
Block Error Ratio.
1.3.6.1.4.1.1316.1.1.1.3.5
mdrmteEventLogTable
SEQUENCE
1.3.6.1.4.1.1316.1.1.1.3.5.1
mdrmteEventLogEntry
SYNTAX
1.3.6.1.4.1.1316.1.1.1.3.5.1.1
mdrmteEventIndex
INTEGER
1.3.6.1.4.1.1316.1.1.1.3.5.1.2
mdrmteEventDate
DisplayString
read-only
Lists the date on which the event
occurred.
1.3.6.1.4.1.1316.1.1.1.3.5.1.3
mdrmteEventTime
DisplayString
read-only
Lists the time when the event
occurred.
1.3.6.1.4.1.1316.1.1.1.3.5.1.4
mdrmteEventType
INTEGER
read-only
Lists the type of event - informational,
minor, major or critical.
1.3.6.1.4.1.1316.1.1.1.3.5.1.5
mdrmteEventDescription
DisplayString
read-only
Textual description of the logged
event.
1.3.6.1.4.1.1316.1.1.1.3.6
mdrmteClearEventLog
INTEGER
write-only
This entry is used to clear the Event
Log.
1.3.6.1.4.1.1316.1.1.1.3.7
mdrmteResetAllFaults
INTEGER
write-only
862-01881 Issue 6
MD
Object ID
Group
Object Type
Access
1.3.6.1.4.1.1316.1.1.1.4
mdrmteAccess
1.3.6.1.4.1.1316.1.1.1.4.1
mdrmteEthernetIPAddress
IpAddress
read-write The IP address associated with
product's Ethernet port (NOTE : USE
A POWER-ON RESET OR RESET
BUTTON POSITION ‘3’ TO ALLOW
ACCEPTANCE OF THE NEW IP
ADDRESS – I.E. IT IS UPDATED IN
NON-VOLATILE MEMORY AND
GETS ACCEPTED BY THE INDOOR
UNIT’S IP STACK AS A VALID
ADDRESS).
1.3.6.1.4.1.1316.1.1.1.4.2
mdrmteEthernetNetMask
IpAddress
read-write The netmask associated with the
Ethernet port.
1.3.6.1.4.1.1316.1.1.1.4.3
mdrmteMaxNumUsers
INTEGER
read-only
If the firmware is complied with the
security feature switched on, users
can log into an IU. This value is read
back from the IU and indicates the
maximum number of users that can
connect to an Indoor Unit.
1.3.6.1.4.1.1316.1.1.1.4.4
mdrmteMaxNumActiveUsers
INTEGER
read-only
If the firmware is built with the security
feature switched on, users can log into
an IU. This entry defines the
maximum number of active users that
can be connected to an Indoor Unit
using IP.
1.3.6.1.4.1.1316.1.1.1.4.5
mdrmteNumActiveUsers
Gauge
read-only
If the firmware is built with the security
feature switched on, users can log into
an IU. This entry defines the number
of active users logged into an IU.
1.3.6.1.4.1.1316.1.1.1.4.6
mdrmteUserTable
SEQUENCE
1.3.6.1.4.1.1316.1.1.1.4.6.1
mdrmteUserEntry
SYNTAX
1.3.6.1.4.1.1316.1.1.1.4.6.1.1
mdrmteUserIndex
1.3.6.1.4.1.1316.1.1.1.4.6.1.2
mdrmteUserName
1.3.6.1.4.1.1316.1.1.1.4.6.1.3
1.3.6.1.4.1.1316.1.1.1.4.6.1.4
INTEGER
DisplayString
read-write If the firmware is built with the security
feature switched on, users can log into
an IU. This entry allows the user to
enter a password associated with their
sign-on name.
mdrmteUserPassword
DisplayString
write-only
mdrmteUserAccessLevel
INTEGER
read-write If the firmware is built with the security
feature switched on, users can log into
an IU. The access entries that are
used are “read_only” and
“administrator”. An administrator can
add and delete new users, assign
passwords, initialise NOVRAM via
SNMP, enter tributary codes, adjust
The default build for firmware DOES NOT include a SECURE LOGIN option.
862-01881 Issue 6
Description
If the firmware is built with the security
feature switched on, users can log into
an IU – this entry allows password
entry.
MD
Object ID
Group
Object Type
Access
1.3.6.1.4.1.1316.1.1.1.4.6.1.5
mdrmteUserActive
INTEGER
read-write Indicates if a user is active or not
based on password entry.
1.3.6.1.4.1.1316.1.1.1.4.6.1.6
mdrmteUserAdd
INTEGER
write-only
In security-enabled mode, allows an
administrator to add users.
1.3.6.1.4.1.1316.1.1.1.4.6.1.7
mdrmteUserDelete
INTEGER
write-only
In security-enabled mode, allows an
administrator to delete users.
1.3.6.1.4.1.1316.1.1.1.4.7
mdrmteRFLinkIPAddress
IpAddress
read-write PPP IP address for the RF Link. The
user need not adjust this parameter.
1.3.6.1.4.1.1316.1.1.1.4.8
mdrmteRFLinkNetMask
IpAddress
read-write PPP IP netmask for the RF Link. The
user need not adjust this parameter.
1.3.6.1.4.1.1316.1.1.1.4.9
mdrmteRemoteIPAddress
IpAddress
read-write Default PPP IP address for the other
end of the RF link.
1.3.6.1.4.1.1316.1.1.1.4.10
MdrmteElementManagerIPAddress
IpAddress
read-write Default PPP IP address for the the
element manager port - 10.13.1.1 for
a 'local IU' and 10.12.1.1 for a 'remote
IU'.
1.3.6.1.4.1.1316.1.1.1.4.11
MdrmteElementManagerNetMask
IpAddress
read-write IP netmask for the Element Manager
PPP port.
1.3.6.1.4.1.1316.1.1.1.4.12
MdrmteIPNegotiable
INTEGER
read-write Determines if the local PPP IP
address is negotiable or not - does
not need to be adjusted by the user.
1.3.6.1.4.1.1316.1.1.1.4.13
MdrmtePPPisDefaultRoute
INTEGER
read-write Determines if PPP interface is the
default route - does not need to be
adjusted by the user.
1.3.6.1.4.1.1316.1.1.1.4.14
MdrmteStaticRouteTable
SEQUENCE
1.3.6.1.4.1.1316.1.1.1.4.14.1
MdrmteStaticRouteEntry
SYNTAX
1.3.6.1.4.1.1316.1.1.1.4.14.1.1 MdrmteStaticRouteIndex
Description
FTP server status, initiate new flash
updates after an FTP upload.
Read_only prevents the ability of the
user to adjust the SETable variables in
the MIB.
INTEGER
1.3.6.1.4.1.1316.1.1.1.4.14.1.2 MdrmteStaticRouteIPAddressDestination IpAddress
read-write Ultimate destination.
1.3.6.1.4.1.1316.1.1.1.4.14.1.3 MdrmteStaticRouteIPAddressMask
IpAddress
read-write net mask, 255.255.255.255 if
destination is host address.
1.3.6.1.4.1.1316.1.1.1.4.14.1.4 mdrmteStaticRouteIPAddressNextHop
IpAddress
read-write Where to forward to.
1.3.6.1.4.1.1316.1.1.1.4.14.1.5 mdrmteStaticRouteInterfaceForNextHop INTEGER
read-write Interface (net) for nexthop.
1.3.6.1.4.1.1316.1.1.1.4.15
mdrmteBridgeEnable
INTEGER
read-write Determines if the system is to act as a
transparent bridge for all Ethernet
packets received.
1.3.6.1.4.1.1316.1.1.1.4.16
mdrmteEthernetFullDuplex
INTEGER
read-write Determines if the Ethernet interface is
full- or half-duplex.
1.3.6.1.4.1.1316.1.1.1.5
mdrmteRelayOutputs
1.3.6.1.4.1.1316.1.1.1.5.1
mdrmteRelay1
1.3.6.1.4.1.1316.1.1.1.5.1.1
mdrmteRelay1Label
DisplayString
read-write A short, descriptive name indicating
the primary function of the relay, most
862-01881 Issue 6
MD
Object ID
Group
Object Type
Access
1.3.6.1.4.1.1316.1.1.1.5.1.2
mdrmteRelay1OpenStateLabel
DisplayString
read-write A short, descriptive name indicating
the primary function of the relay in the
open state, most probably in terms of
the equipment connected to it.
1.3.6.1.4.1.1316.1.1.1.5.1.3
mdrmteRelay1ClosedStateLabel
DisplayString
read-write A short, descriptive name indicating
the primary function of the relay in the
closed state, most probably in terms
of the equipment connected to it.
1.3.6.1.4.1.1316.1.1.1.5.1.4
mdrmteRelay1Reserved
INTEGER
1.3.6.1.4.1.1316.1.1.1.5.1.5
mdrmteRelay1CurrentState
INTEGER
1.3.6.1.4.1.1316.1.1.1.5.1.6
mdrmteRelay1ScriptTable
SEQUENCE
1.3.6.1.4.1.1316.1.1.1.5.1.6.1
mdrmteRelay1ScriptEntry
1.3.6.1.4.1.1316.1.1.1.5.1.6.1.1 mdrmteRelay1ScriptIndex†
Description
probably in terms of the equipment
connected to it.
read-write The current state of the relay. Used to
activate/deactivate a relay.
SYNTAX
INTEGER
1.3.6.1.4.1.1316.1.1.1.5.1.6.1.2 mdrmteRelay1ScriptID
INTEGER
read-write Defines which of the listed alarms can
cause a relay to activate.
1.3.6.1.4.1.1316.1.1.1.5.1.6.1.3 mdrmteRelay1ScriptActiveLocal
INTEGER
read-write Defines if the script is active or not for
local relay activation.
1.3.6.1.4.1.1316.1.1.1.5.1.6.1.4 mdrmteRelay1ScriptActiveRemote
INTEGER
read-write Defines if the script is active or not for
remote relay activation.
1.3.6.1.4.1.1316.1.1.1.5.2
mdrmteRelay2
1.3.6.1.4.1.1316.1.1.1.5.2.1
mdrmteRelay2Label
DisplayString
read-write A short, descriptive name indicating
the primary function of the relay, most
probably in terms of the equipment
connected to it.
1.3.6.1.4.1.1316.1.1.1.5.2.2
mdrmteRelay2OpenStateLabel
DisplayString
read-write A short, descriptive name indicating
the primary function of the relay in the
open state, most probably in terms of
the equipment connected to it.
1.3.6.1.4.1.1316.1.1.1.5.2.3
mdrmteRelay2ClosedStateLabel
DisplayString
read-write A short, descriptive name indicating
the primary function of the relay in the
closed state, most probably in terms
of the equipment connected to it.
1.3.6.1.4.1.1316.1.1.1.5.2.4
mdrmteRelay2Reserved
INTEGER
1.3.6.1.4.1.1316.1.1.1.5.2.5
mdrmteRelay2CurrentState
INTEGER
1.3.6.1.4.1.1316.1.1.1.5.2.6
mdrmteRelay2ScriptTable
SEQUENCE
1.3.6.1.4.1.1316.1.1.1.5.2.6.1
mdrmteRelay2ScriptEntry
SYNTAX
read-write The current state of the relay. Used to
activate/deactivate a relay.
1.3.6.1.4.1.1316.1.1.1.5.2.6.1.1 mdrmteRelay2ScriptIndex
INTEGER
1.3.6.1.4.1.1316.1.1.1.5.2.6.1.2 mdrmteRelay2ScriptID
INTEGER
read-write Defines which of the listed alarms can
cause a relay to activate.
1.3.6.1.4.1.1316.1.1.1.5.2.6.1.3 mdrmteRelay2ScriptActiveLocal
INTEGER
read-write Defines if the script is active or not for
Relay scripting is not activated in Versions 1.0 & 2.0 of the IU firmware release.
862-01881 Issue 6
MD
Object ID
Group
1.3.6.1.4.1.1316.1.1.1.5.2.6.1.4 mdrmteRelay2ScriptActiveRemote
Object Type
Access
Description
local relay activation.
INTEGER
read-write Defines if the script is active or not for
remote relay activation.
1.3.6.1.4.1.1316.1.1.1.6
mdrmteOptoInputs
1.3.6.1.4.1.1316.1.1.1.6.1
mdrmteOptoInput1
1.3.6.1.4.1.1316.1.1.1.6.1.1
mdrmteOptoInput1Label
DisplayString
read-write A short, descriptive name indicating
the primary function of the contactclosure input in the closed state, most
probably in terms of the equipment
connected to it.
1.3.6.1.4.1.1316.1.1.1.6.1.2
mdrmteOptoInput1State
INTEGER
read-only
1.3.6.1.4.1.1316.1.1.1.6.2
mdrmteOptoInput2
1.3.6.1.4.1.1316.1.1.1.6.2.1
mdrmteOptoInput2Label
DisplayString
read-write A short, descriptive name indicating
the primary function of the contactclosure input in the closed state, most
probably in terms of the equipment
connected to it.
1.3.6.1.4.1.1316.1.1.1.6.2.2
mdrmteOptoInput2State
INTEGER
read-only
Indicates if the opto input contactclosure input is active (on) or not (off).
Indicates if the opto input contactclosure input is active (on) or not (off).
10.3 The MIB elements – TRAP DESCRIPTIONS
MdrmteTrapUndefined: Informational
MdrmteTrapPayloadLOS: Critical
Indicates a Loss of Signal identified on the INPUT TO a tributary.
MdrmteTrapPayloadAIS: Critical
Indicates an Alarm Indication Signal ' all 1's ' identified/sensed on the INPUT
TO a tributary.
MdrmteTrapLinkUnavailable: Critical
Indicates, based on G.826 criteria if the RF Link has become unavailable.
MdrmteTrapLinkFrameUnlock: Critical
Indicates a Frame Unlock condition identified in the Indoor Unit.
MdrmteTrapLinkOuSynthUnlock: Critical
Indicates if a synthesizer unlock condition was identified in the Outdoor Unit.
MdrmteTrapLinkMinorPERExceeded: Minor
Indicates the minor packet error rate threshold was exceeded.
MdrmteTrapLinkMajorPERExceeded: Major
Indicates the major packet error rate threshold was exceeded.
MdrmteTrapLinkCriticalPERExceeded: Critical
Indicates the critical packet error rate threshold was exceeded.
10
MdrmteTrapLinkESRExceeded: Minor
Indicates the Link Errored Second Ratio Threshold limit was exceeded.
11
MdrmteTrapLinkSESRExceeded: Critical
Indicates the Link Severely Errored Second Ratio threshold limit was
exceeded.
12
MdrmteTrapLinkBBERExceeded: Minor
Indicates the Link Background Block Error Rate threshold limit was exceeded.
13
MdrmteTrapFTPUploadDone: Informational
Indicates FTP Upload done.
14
MdrmteTrapFlashEraseFail: Informational
Indicates failure to erase Application flash.
862-01881 Issue 6
MD
15
MdrmteTrapFirmwareUpgradePass: Informational
Indicates that firmware was uploaded successfully.
16
MdrmteTrapFirmwareUpgradeFail: Informational
Indicates that there was a firmware upload failure.
17
MdrmteTrapInterstationCommsTimeOut: Major
Indicates an interstation communications timeout.
18
MdrmteTrapInterstationCommsInvalidResponse: Minor
Indicates a communications error on the interstation overhead link.
19
MdrmteTrapOUCommsTimeOut: Major
Indicates an Outdoor Unit communications timeout.
20
MdrmteTrapOUCommsInvalidResponse: Minor
Indicates an Outdoor Unit communications error - an invalid response was
received.
21
MdrmteTrapOUCommsTxFail
Indicates Outdoor Unit communications transmit failure.
22
MdrmteTrapSSPCRCError: Minor
Simple Serial Protocol CRC error identified.
23
MdrmteTrapSSPLengthError: Minor
Simple Serial Protocol Length error identified.
24
mdrmteTrapOptoInput1Off: Major
Contact closure input off state detected - Opto 1.
25
mdrmteTrapOptoInput1On: Major
Contact closure input off state detected - Opto 1.
26
mdrmteTrapOptoInput2Off: Major
Contact closure input off state detected - Opto 2.
27
mdrmteTrapOptoInput2On: Major
Contact closure input on state detected - Opto 2.
28
mdrmteTrapUserLoginFailed: Informational
With security MODE ON - indicates a user attempted to log on and the
attempt failed.
29
mdrmteTrapUserLogoutFailed: Informational
With security MODE ON - indicates a user attempted to log out and the
attempt failed.
30
MdrmteTrapUserAddFailed: Informational
With security MODE ON - indicates there was an attempt to add a user, but
the attempt failed.
31
mdrmteTrapUserDeleteFailed: Informational
With security MODE ON - indicates there was an attempt to remove/delete a
user, but the attempt failed.
32
MdrmteTrapUserLogIn: Informational
With security MODE ON - indicates a user logged in.
33
MdrmteTrapUserLogOut: Informational
With security MODE ON - indicates a user logged out.
34
MdrmteTrapUserAdd: Informational
With security MODE ON - indicates a user was added successfully.
35
MdrmteTrapUserDelete: Informational
With security MODE ON - indicates a user was deleted successfully.
36
MdrmteTrapOUSetBandPlan: Informational
Indicates the Outdoor Unit channel/band plan was changed.
37
mdrmteTrapOUSetTxChannel: Informational
Indicates the Outdoor Unit transmit frequency was changed.
38
mdrmteTrapOUSetRxChannel: Informational
Indicates the Outdoor Unit receive frequency was changed.
39
MdrmteTrapOUEepromWrite: Minor
Indicates there was an attempt to write to the Outdoor Unit EEPROM.
40
mdrmteTrapOUSetTxPower: Informational
Indicates there was an attempt to change the transmit power.
41
MdrmteTrapOUSetPNCode – NA
Deprecated.
42
MdrmteTrapOUSetAutoRecovery
Indicates there was an attempt to change the “auto recovery” setting.
43
MdrmteTrapOUProgramConfig
Deprecated.
44
mdrmteTrapOUChangeRFLoopback: Informational
Indicates a change the OU RF Loopback setting was implemented.
45
mdrmteTrapOUChangeBBPLoopback: Informational
Indicates a change the Baseband Processor Loopback setting was
implemented.
46
MdrmteTrapOUWriteBBP: Minor
Indicates there was an attempt to write to the Baseband Processor.
47
MdrmteTrapSetDate: Informational
Indicates the Indoor Unit date was adjusted.
48
MdrmteTrapSetTime: Informational
Indicates the Indoor Unit time was adjusted.
49
MdrmteTrapSynchronizeSwRTC: Informational
Indicates the Indoor Unit's time was synchronized with its real-time clock.
862-01881 Issue 6
MD
50
MdrmteTrapSetRelayLabel
A relay label was changed.
51
MdrmteTrapSetRelayOpenStateLabel
A relay open-state label was changed.
52
mdrmteTrapSetRelayClosedStateLabel
A relay closed-state label was changed.
53
MdrmteTrapSetRelayDefaultState: NA
Deprecated.
54
mdrmteTrapSetRelayCurrentState: Informational
Relay's current state has changed.
55
mdrmteTrapRelayScriptEnable
Relay scripting is enabled.
56
mdrmteTrapRelayScriptDisable
Relay scripting is disabled.
57
MdrmteTrapGetEventLog: Informational
Indoor Unit's event log is being accessed.
58
MdrmteTrapClearEventLog: Informational
Indoor Unit's event log is being cleared.
59
MdrmteTrapSelfTestFailure: Major
Indoor Unit's self test failed.
60
MdrmteTrapProcessorReset: Critical
There was an Indoor Unit processor reset.
61
MdrmteTrapEtherRx
There was an Indoor Unit Receive Ethernet buffer error.
62
MdrmteTrapTest: Informational
Test trap.
63
MdrmteTrapGenericText
Test trap.
64
mdrmteTrapGenericText_Data
Test trap.
65
mdrmteTrapGenericText_DecData
Test trap.
66
mdrmteTrapSocket_Error
Test trap.
862-01881 Issue 6
MDR5800 User Manual
11 APPENDIX C: SETUP OF A PC (WIN 95, 98, NT) TO ALLOW
PINGING OF A ‘REMOTE’-CONFIGURED INDOOR UNIT
The following diagram shows the default (factory) network IP addresses assigned to the various
network ports on the MDR System: ROUTING CONFIGURATION
11.1
IP CONFIGURATION OF THE MDR5800 – ROUTING CONFIGURATION
MDR 5800 - ROUTING CONFIGURATION
PPP
WIRELESS
Ethernet
10-BaseT
10.2.1.2
10.10.9.9
10.10.9.10
10.11.1.2
10.13.1.1
10.12.1.1
PPP
RS232
PPP
RS232
"NEAR"
"FAR"
Ethernet
10-BaseT
Hub
Browser/NMS
10.13.1.2
Laptop computer
Browser/NMS
10.12.1.2
Laptop computer
Browser/NMS
10.2.1.3
Laptop computer
To allow pinging of an IU configured as a "remote unit" i.e. with an IP address of (10.11.1.2) when
the PC has a 10.2.1.3 IP address, 10.2.1.2 default gateway and netmask 255.255.0.0, create batch
files.
Batch file 1 - addroute.bat
route add 10.11.0.0 mask 255.255.0.0 10.2.1.3
Batch file 1 adds a route so that the IP stack on the PC "knows" where to send IP packets destined
for the net 10.11.0.0
If you want to delete the route, use
862-01881 Issue 6
Page 105
MDR5800 User Manual
Batch file 2 - delroute.bat
route delete 10.11.0.0
If you want a screen printout of the routes the PC is using, use the command line entry:
route print
NOTE
DO NOT ALLOW AN RF LINK TO ESTABLISH BEFORE DOING A PING on the remote IU
(with 10.11.1.2 as an IP address) - if the RF link was established before, use the front panel
button "position 3" to reset the IU before attempting to ping.
862-01881 Issue 6
Page 106
MDR5800 User Manual
11.2
IP CONFIGURATION OF THE MDR5800 – BRIDGING AND ROUTING
CONFIGURATION
The following diagram shows the default (factory) network IP addresses assigned to the various
network ports on the MDR System: BRIDGING AND ROUTING CONFIGURATION.
MDR 5800 - BRIDGING OR ROUTING
DEFAULT CONFIGURATION
PPP
WIRELESS
Ethernet
10-BaseT
10.2.1.2 R
192.168.1.2 B
192.168.4.2
10.11.1.2 R
192.168.1.3 B
192.168.4.3
192.168.2.2
192.168.3.3
PPP
RS232
PPP
RS232
"NEAR"
"FAR"
Ethernet
10-BaseT
Hub
Browser/NMS
192.168.2.3 B
Laptop computer
Browser/NMS
192.168.3.2 B
Laptop computer
Browser/NMS
10.2.1.3 R
192.168.1.4 B
Laptop computer
Note : The netmask for all the 192.168.x.x addresses is 255.255.255.0
The netmask for all the 10.x.x.x addresses is 255.255.0.0
R above refers to “IP routing”
B above refers to “Ethernet bridging”
862-01881 Issue 6
Page 107
MDR5800 User Manual
12 APPENDIX D: MDR5800 HARDWARE VERSION 1, 2.X
DIFFERENCES, COMPATIBILITY SUMMARY
Version 1 hardware (Indoor and Outdoor Units) is incompatible with Version 2.x hardware.
•
The Indoor Unit /Outdoor Unit Twisted Pair Data Interconnection for Version 2 hardware
uses 2 twisted pair cables to convey payload and Outdoor Unit control signals whereas
Version 1 hardware uses 4 twisted pair cables.
Notes :
Version 2.x firmware (can be uploaded into the Indoor Unit using the NMS’s Maintenance option)
that can be used in Version 1.x hardware must be obtained from the product manufacturer. The
file is not the same file that is used with Version 2.x hardware.
Updated RSSI and Power control functionality have been added to Version 2.x hardware and
firmware.
Version 2.x firmware has
1. FTP upload functionality (needs to be activated via the MIB)
2. IP Bridging functionality (half and full duplex – selectable via the MIB)
3. Band Plan C
4. Refer to the MIB section of this manual and look for the † symbol to see what MIB-related
functionality is in place/activated/planned for Version 2.x + firmware.
5. Functional RF Loopback built-in test feature.
Version 2.x NMS has
1. Ability to allow the user to connect to the Indoor Unit using PPP (via a serial cable
interface to the IU’s front panel Element Manager RS232 port) or via Ethernet (via the
front panel RJ45 connector: 10BaseT).
2. Graphical Spectrum Analyzer display
By default, firmware provided for the Indoor Units does not provide a secure login feature (thereby
limiting a user’s ability to ‘set’ MIB variables). Suitably adapted firmware versions (dependent on
hardware version) need to be requested from the product manufacturer to allow activation of this
feature.
862-01881 Issue 6
Page 108
M
13 APPENDIX E: FIXED ANTENNAS
The table below identifies the distances where the 1mW/cm2 exposure limits may be exceeded during
continuous transmission using the proposed fixed antennas.
Manufacturer
Type
Model
Gain
Numeric
(dBi)
gain
Channel
Peak Power Calculated Minimum RF Exposure
(mW)
Separation Distance
Distance
(m)
(m)
Gabriel
Dish
SSSP2 52B
29.0
794.3
239.9
1.2
Gabriel
Flat
panel
DFPD1-52
23.9
245.5
239.9
0.7
MTI
Flat
panel
MT-20004
28.0
631.0
239.9
1.1
WARNING: It is the responsibility of the professional installer to ensure that when using the outdoor
antenna kits in the United States (or where FCC rules apply), only these antenna configurations shown in
the table in section 1.4 are used. The use of any antenna other than those listed is expressly forbidden
in accordance to FCC rules CFR47 part 15.204.
FCC Radiation Exposure Statement
i)
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment when installed as directed. This equipment should be installed and operated with fixmounted antennas that are installed with a minimum of 2 meters of separation distance between the
antenna and all persons body during normal operation and the antennas as shown above.
862-01881 Issue 6

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Creator                         : Microsoft Word
Create Date                     : Monday, April 23, 2001 3:53:08 PM
Title                           : 
Author                          : 
Producer                        : Acrobat PDFWriter 3.0 for Windows
Subject                         : 
Modify Date                     : 2001:04:28 05:29:48-07:00
Page Count                      : 109
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ONJ-MDR5800ET

Navigation menu