CYCLADES™ ACS 6000
Command Reference Guide

FCC Warning Statement
The Cyclades™ ACS 6000 advanced console server has been tested and found to comply
with the limits for Class A digital devices, pursuant to Part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the Installation and Service Manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user is required to correct the problem at his or her own expense.

Notice about FCC Compliance for All Cyclades ACS Advanced Console Server
Models
To comply with FCC standards, the Cyclades ACS 6000 advanced console server requires
the use of a shielded CAT 5 cable for the Ethernet interface. Notice that this cable is not
supplied with the product and must be provided by the customer.

Canadian DOC Notice
The Cyclades ACS 6000 advanced console server does not exceed the Class A limits for
radio noise emissions from digital apparatus set out in the Radio Interference Regulations of
the Canadian Department of Communications.
L’Cyclades ACS advanced console server n’émete pas de bruits radioélectriques dépassant
les limites applicables aux appareils numériques de la classe A prescrites dans le règlement
sur le brouillage radioélectrique edicté par le Ministère des Communications du Canada.

Safety and EMC Approvals and Markings
FCC Class A (USA), CE Class A (EU), ICES-003 (Canada), VCCI (Japan), C-Tick (Australia),
A-Tick (Australia, with internal modem), UL 60950-1 (USA), cUL (Canada), EN-60950-1
(EU), CB, KCC (Korea), GS, GOSTR (Russia)

Cyclades™ ACS 6000
Command Reference Guide

Avocent, the Avocent logo, The Power of Being There, Cyclades and DSView are
trademarks or registered trademarks of Avocent Corporation or its affiliates in the
U.S. and other countries. All other marks are the property of their respective
owners.

© 2011 Avocent Corporation.
590-770-501E

Symbols Used
NOTE: The following symbols may appear within the documentation or on the appliance.

Instructions
This symbol is intended to alert the user to the presence of important operating and
maintenance (servicing) instructions in the literature accompanying the appliance.
Dangerous Voltage
This symbol is intended to alert the user to the presence of uninsulated dangerous
voltage within the product’s enclosure that may be of sufficient magnitude to constitute
a risk of electric shock to persons.
Power On
This symbol indicates the principal on/off switch is in the on position.
Power Off
This symbol indicates the principal on/off switch is in the off position.
Protective Grounding Terminal
This symbol indicates a terminal which must be connected to earth ground prior to
making any other connections to the equipment.
Functional Earthing Terminal
This symbol indicates a terminal which serves the purpose of establishing chassis
ground equal potential.

ii

TA B LE  OF C ON TE N TS

Introduction, Navigation and Commands
Access Options and How to Log Into the CLI

1
2

Configuration Tasks Performed With the CLI

3

CLI Navigation

4

Autocompletion

5

Parameters

6

Command Line Syntax

6

CLI Command Set
Commands Used for the CLI

9
9

help

9

add

10

delete

10

cd

10

pwd

11

connect

11

sniff

11

share

12

disconnect

12

exit/quit

12

ftp

12

scp

13

set

13

commit

13

revert

13

ls

14

show

14

list_configuration

14

cycle, on, off, lock and unlock

15

passwd

16

opiepasswd

16

iii

Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

wiz
Special Multi-session Commands

17
17

list_shared_session

17

kill_shared_session

17

sendmsg

17

show_databuf and show_appliance_databuf

18

cleandbuf and clean_appliance_databuf

18

CLI Equivalent Actions to Web Manager Checkbox Selection
Port Access and Configuration Examples
View Information About the Console Server and Connected Devices

19
21
22

Connect to a Device Console Connected to a Serial Port

24

Accessing Serial Ports using ts_menu

24

Manage Power for a Device Connected to an Outlet on a PDU

25

Port Configuration Examples

25

CLI Overview for Administrators
System
System/Security

29
29
30

System/Date and Time

31

System/Help and Language

32

System/General

32

System/Boot Configuration

33

System/Information

33

System/Usage

33

Network

34

Network/Settings

34

Network/IPv4 and IPv6

35

Network/Devices

35

Network/Hosts

36

Network/Firewall

38

Network/IPSec(VPN)

38

Table of Contents     iv

Network/SNMP
Wiz command
Ports

39
39
40

Auxiliary ports

43

Pluggable Devices

44

Authentication

45

Users

45

Syslog

46

Events_and_Logs

47

Power Management

48

Active Sessions Information

49

Appendix A: Enabling Firmware Upgrades When the Boot Image is not in
Flash

51

Appendix B: Migration CLI

53

Appendix C: Su and Sudo Commands

59

Appendix D: Technical Support

63

v     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

1

1

Introduction, Navigation and
Commands

The Cyclades™ ACS 6000 advanced console server is a 1U appliance that serves as a single
point for access and administration of connected devices, such as target device consoles, modems
and power devices. Console servers support secure remote data center management and out-ofband management of IT assets from any location worldwide.
On console servers, administration can be performed and connected devices can be accessed with
the Command Line Interface (CLI) utility, with the web manager or with DSView™ 3
management software (version 3.5.1 and greater). Multiple users and administrators can be logged
into the console server and connected to ports at the same time.
This guide describes how to access and navigate the CLI utility and how to use it after the
console server has been installed and assigned an IP address. For information on how to install or
operate your console server using the web manager, see the Cyclades ACS 6000
Installation/Administration/User Guide.
The console ports of servers, external modems or power distribution units (PDUs) can be
connected to serial ports on the console server. Supported PDUs include Avocent
PM1000/2000/3000s, Cyclades PM IPDUs, Avocent SPC power devices and Server Technology
CDUs. Either a PDU or an external modem can be connected to the AUX/Modem port if the port
is not factory-configured for an internal modem.
Console server ports are shown in the following figure, and descriptions are listed in Table 1.1.

2     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

Figure 1.1: Console Server Ports

Table 1.1: Console Server Port Descriptions
Number

Description
Serial Port 1

1

NOTE: Serial ports are also referred to with tty device names, such as ttSy1, ttyS2 and so
forth.

2

Eth1 (eth1)

3

Eth0 (eth0)
AUX/Modem Port (ttyM1 or ttyA1)

4

5

NOTE: If an internal modem is ordered and factory installed, this port is configured internally as a modem port. If an internal modem is not installed, the port is configured as an
auxiliary port, and a PDU or an external modem can be connected to it. The figure shows
an external modem connected.
Console Port

Access Options and How to Log Into the CLI
The CLI utility can be accessed in the following ways:

Chapter 1: Introduction, Navigation and Commands

3

•

Through a local terminal or a computer that has a terminal emulation program connected to
the console port of the console server with session settings of 9600, 8, N and 1, with no
flow control.

•

After the console server is connected to the network and has an IP address, it can be
accessed by one of the following methods:
•

An SSH or Telnet client on a remote computer (if the SSH or Telnet protocol is
enabled in the selected Security Profile)

•

With the Web Manager - Overview - Appliance Session button

•

With DSView 3 management software

NOTE: For details on the remote access methods and IP address configuration options, see the Cyclades ACS
6000 Installation/Administration/User Guide.

Administrators have full access to the CLI and to connected devices. An administrator can
authorize regular users to access ports, manage power, manage data buffer storage and use one
or more console server administration tools. Users can always change their own passwords.
To start the CLI:
1.

Access the CLI through the console port, with Telnet, SSH or through the web manager.

2.

Enter the username and password at the prompt. The cli-> prompt appears.
Welcome to ACS6000 .
Type help for more information
--:- / cli->

NOTE: The default password for admin is avocent and for root is linux . The password for these users may have
been changed during installation of the console server. If not, change the default root and admin passwords to avoid
potential security breaches.

Configuration Tasks Performed With the CLI
NOTE: This manual provides some configuration procedures as examples of how to use the CLI; an administrator
who wants to use the CLI for configuration should reference the installation/administration/user guide for more
information.

The navigation structure of the CLI mirrors that of the web manager. Options and parameters
are also the same, except that spaces in web manager options and parameters are replaced with
underscores (_), as in: system_tools. Examples that show how to select an option in the web
manager use a dash surrounded by two spaces ( - ). In the CLI, two similar options in a path are
separated by a forward slash (/).

4     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

For example, in the web manager, user configuration is done when an administrator selects Users - Local Accounts - User Names to get to the User Names screen. To navigate to the
equivalent configuration level in the CLI, an administrator would use the cd command
followed by the path: cd /users/local_accounts/user_names.
Administrators should log into the CLI in one window and log into the web manager in
another window to see how the menu options in the web manager map to the navigation
options in the CLI. Configuration with the CLI also requires mastery of the following
information on CLI navigation and of the CLI commands shown in Chapter 2.

CLI Navigation
The CLI navigation options are in a nested tree configuration.
NOTE: When a command line is shown in an example, and the step starts with “Enter,” or when a syntax example is
given, the user should type the command as shown and then press Enter . The Enter key is not shown in
command line examples unless needed for clarity.

When a user logs in the CLI, the prompt indicates the user is at the / level.
--:- / cli->

No parameters can be set at this level of the navigation tree.
At any CLI prompt at any level, if you type cd and press Tab Tab, the navigation options (path
elements) for that level are listed. Different options appear for administrators and for authorized
users.
•

When an administrator types the cd command and then presses Tab Tab at the / prompt, the
following navigation options (path elements) appear.
--:- / cli-> cd

access/
active_sessions/
system_tools/
authentication/
change_password/
events_and_logs/

monitoring/
network/

system/

pluggable_devices/
ports/
power_management/

users/

When a regular user types the cd command and then presses Tab Tab at the / prompt, the
following navigation options appear.
--:- / cli-> cd
access/ power_management/

Enter cd  to move down one or more levels of the navigation
tree:

Chapter 1: Introduction, Navigation and Commands

5

--:- / cli-> cd system_tools

A prompt like the following appears at each level:
--:- system_tools cli->
NOTE: CLI commands are case sensitive.

At any level, you can press Tab Tab at the prompt to see the commands that can be entered at
the current level.
---:- system_tools cli->
batch_mode ls scp
cd opiepasswd shell
commit passwd show
echo pwd shutdown
exit quit upgrade_firmware
ftp reboot whoami
help restore_configuration wiz
hostname revert
list_configuration save_configuration
---:- system_tools cli->

If you know the path, you can enter multiple path elements in a single command separated with
forward slashes (/).
--:- / cli-> cd ports/serial_ports/
--:- serial ports cli->

Enter cd .. to move up one level of the navigation tree. Enter cd ../..[/..] to move up multiple
levels.
--:- serial ports cli-> cd ../..
--:- / cli->

Autocompletion
Autocompletion allows you to type the first few letters of a command or navigation option and
then press Tab. The rest of the name is filled in automatically if the letters typed are unique to
one command or to a navigation option at that level. If the letters match more than one of the
commands or navigation options for that level, the matching options are listed.
For example, if you type cd acc and press Tab at the CLI prompt from the / level, the access
option will be completed.
--:- / cli-> cd acc

6     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

--:- / cli-> cd access

If you then press Enter, you are changed to the access level, and the access level prompt
appears.
--:- access cli->

The following example illustrates a case when more than one command matches the letters
typed.
--:- / cli-> sh
shell show

Parameters
Some CLI commands take parameters. If you press Tab Tab after a command that requires a
parameter, you are prompted to enter the parameter.

Command Line Syntax
NOTE: Square brackets ([ ]) denote an optional element. Each element is separated by a space. There are no
spaces between sub-elements.

Command only (help, pwd):
--:-  cli-> 

Commands with paths only (cd, ls, add):
--:-  cli->  [Path]

Commands with targets (del):
--:-  cli->  [Path] 

Commands that require parameters (set):
--:-  cli->  [Path] 

Commands with values only (sendmsg, ftp...):
--:-  cli->  [Path] 
where:
Path := path_elem[/path_elem]*
path_elem := . | .. | Section_Label | ^/
Targets := Row_Label(,Row_Label)
Params := Param_Names=PValues
Param_Names := Param_Label(:Param_Label)*
PValues := Value_text(,Value_text)*
Values := Value_text Value_text

Chapter 1: Introduction, Navigation and Commands
Section_Label
Param_Label
Value_text := labels or data from the UIC.

Syntax used:
^ : beginning of the element
* : 0 - many
| : or
() : group

7

8     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

9

CLI Command Set

2

Commands Used for the CLI
This chapter describes the general commands used when accessing the console server with the
command line interface.
NOTE: Most of the commands work from any location when the path to the command parameter is included.
NOTE: The word “node” refers to an entity such as a route, host or user, which can be added, configured or deleted.

help
Generate a help message about how to navigate the CLI.
Syntax:
--:- / cli-> help
- Thank you for using the cli This interface allows you to easily modify configurations
to customize and define the functionality of your unit.
Press   to see the list of available commands.
Please refer to the Reference Guide for a description of
commands, special keys and additional information on how to
use this interface.
Some basic and useful keys are:
up/down arrow - navigates up/down in the command history
tab (once/twice) - shows the next possible option(s)
Other hints:
Use backslash '\' to escape spaces, '\' and other control

10     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

characters when assigning values to parameters.

add
Add a node.
Syntax:
--:- / cli-> add 
Example:
--:- / cli-> add network/hosts
--:#- [hosts] cli->

delete
Delete a node.
Syntax:
--:- / cli-> delete  

cd
Change directory (level).
Syntax:
--:- / cli-> cd 

Example:
--:- / cli-> cd access

Displays the following:
--:- access cli->

Example:
--:- access cli-> cd ..
-or--:- access cli-> cd ../

Moves up one directory level and displays the following:
--:- / cli->

Example:
--:- access cli-> cd /

Moves to the top level and displays the following:
--:- / cli->

Example:

Chapter 2: CLI Command Set
--:- access cli-> cd /information

Displays the following:
--:- information cli->

pwd
Display the path to the current level (print working directory).
Syntax:
--:- / cli-> pwd

connect
Connect to a serial port.
Syntax:
--:- access cli-> connect 

Example:
--:- access cli-> connect 77-77-70-p-2

-or(Optional) From the default directory:
--:- / cli-> connect access/77-77-70-p-2

Displays the following:
Password:

-orType the hotkey to suspend the connection:
Ctrl + z
NOTE: The connect, sniff and share commands allow you to connect to serial ports. These commands require
authentication when single sign-on is disabled, so the password must be entered to authenticate the user in the
authentication type configured for the serial port. If single sign-on is enabled or the user has already been
authenticated, the session is opened.

sniff
Connect to a serial port as an additional, view-only user.
Syntax:
--:- access cli-> sniff 

Example:
--:- access cli-> sniff 77-77-70-p-2

11

12     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

Displays the following:
Password:

-orType the hotkey to suspend the connection:
Ctrl + z

share
Connect to a serial port as an additional, read/write user.
Syntax:
--:- access cli-> share 

Example:
--:- access cli-> share 77-77-70-p-2

Displays the following:
Password:

-orType the hotkey to suspend the connection:
Ctrl + z

disconnect
Use the text session hot key to suspend the target session and return to the CLI.
Syntax:
Ctrl+z

exit/quit
Exit the CLI and return to the login prompt.
Syntax:
--:- / cli-> exit

-or--:- / cli-> quit

ftp
Connect to a remote FTP server.
Syntax:

Chapter 2: CLI Command Set

13

--:- / cli-> ftp [|]
NOTE: You must log into the CLI as root to have full control over the local directory path. All normal FTP commands
apply.

scp
Perform a secure shell copy.
Syntax:
--:- / cli-> scp [[user@]host1:]file1 [...] [[user@]host2:]file2

set
Set a parameter.
Syntax:
--:- / cli-> set  =

After a parameter has been changed using the set command, a pair of asterisks appear at the
beginning of the CLI prompt.
**:- / cli->

Save the change:
**:- / cli-> commit

-orUndo the change:
**:- / cli-> revert
NOTE: After a commit or revert command, the asterisks at the beginning of the CLI prompt are replaced by
hyphens. Asterisks will not appear after the execution of the set command if using wizard mode, which can be
recognized by a prompt that has a pound sign after the colon and the current directory in square brackets (example,
--:#- [hosts] cli->).

commit
Save settings.
Syntax:
**:- settings cli-> commit

revert
Undo a previous parameter setting.
Syntax:
**:- / cli-> revert

14     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

ls
Show the available directories or subnodes at the current location.
Syntax:
--:- / cli-> ls

Example:
--:- / cli-> ls authentication
appliance_authentication/
authentication_servers/
--:- / cli->

show
Show the content of the current location (shows tables and parameters with current values).
Syntax:
--:- / cli-> show

Example:
--:- language cli-> show
appliance_languate = english
--:- / cli->

list_configuration
List the configuration in a format that allows pasting the output directly on the appliance
session (console, SSH or Telnet) in order to (re)configure the unit.
All configurable parameters are listed under the current node. When the parameter is not
configured, the parameter name has the number sign character (#) as its prefix.
Syntax:
--:- / cli-> list_configuration

Example:
.list configuration of network device eth0:
--:- cli-> cd network/devices/eth0
--:- eth0 cli-> list_configuration
echo off
cd /network/devices/eth0
batch_mode
set status=enabled

Chapter 2: CLI Command Set

15

set ipv4_method=dhcp
#set ipv4_method=static #ipv4_address=192.168.160.10 #ipv4_
mask=255.255.255.0
#set ipv4_method=ipv4_address_unconfigured
#set ipv6_method=stateless
#set ipv6_method=dhcpv6
#set ipv6_method=static #ipv6_address= #ipv6_prefix_length=
set ipv6_method=ipv6_address_unconfigured
set mode=auto
submit
echo on
commit
--:- eth0 cli->
NOTE: Check the configuration of the program used to open a session against the appliance (SSH/Telnet,
TeraTerm / HypertTerminal for console, and so on) to avoid the inclusion of a line feed character in lines that exceed
terminal width, because this will affect the past operation.

cycle, on, off, lock and unlock
Control power on outlets on a PDU that is either connected to a serial port or to the
AUX/Modem port when the port is enabled and configured with the Power Profile.
NOTE: Lock and unlock commands are only supported on Cyclades and Avocent PDUs.

To power control (on, off, cycle) all outlets of PDUs or outlets merged to a target
(serial port configured as CAS profile with merged outlets):
1.

Go to the access level.
--:- / cli-> cd/access

2.

Launch the power command with the argument being the target name or PDU ID.
--:- access cli-> [cycle|on|off][]|]

To power control (on, off, cycle) outlets of one specific PDU:
1.

Go to the PDU level under access.
--:- / cli-> cd access/

2.

Launch the power command with a specific outlet (number or name), range of outlets (use a
hyphen to specify the range) or list of outlets (number or name separated by a comma).
--:-  cli-> [cycle|on|off][|]

-or--:-  cli-> [cycle|on|off]- cli-> [cycle|on|off],

To power control (on, off, cycle, lock, unlock) outlets of one specific PDU under the
power management level:
1.

Go to the outlet level for the specific PDU.
--:- / cli-> cd power_management/pdus//outlets

2.

Launch the power command with a specific outlet number, range of outlets (use a hyphen
to specify the range) or list of outlets (number or name separated by a comma).
--:- outlets cli-> [cycle|on|off] []

-or--:- outlets cli-> [cycle|on|off] - [cycle|on|off] ,

passwd
Configure the password for the current user. The terminal does not echo the password.
Syntax:
--:- / cli-> passwd

opiepasswd
Configure a one time password (OTP) for the local user. After you type the command, you will
be asked for the pass phrase to use for the OTP.
NOTE: Use this command to restart the sequence number.

Syntax:
--:- / cli-> opiepasswd -f -c 

Example:
opiepasswd -f -c teste
Adding teste:
Only use this method from the console; NEVER from remote. If you are
using telnet, xterm, or a dial-in, type ^C now or exit with no password.
Then run opiepasswd without the -c parameter.
Using MD5 to compute responses.
Enter new secret pass phrase:
Again new secret pass phrase:
ID teste OTP key is 499 AC0241
FOOD HUGH SKI ALMA LURK BRAD

Chapter 2: CLI Command Set

17

wiz
Configures the IP parameters for the Eth0 interface. Shows the current configuration and asks
for new values for the following parameters:
•

Status of the interface (enabled or disabled)

•

IPv4 method (dhcp or static)

•

IPv6 method (dhcp or static)

•

IP address, mask and gateway (if static is chosen for either of the previous parameters)

•

DNS Primary Server, Secondary Server, Domain Name and Hostname

After setting all parameters, confirm that all parameters are correct to save them.

Special Multi-session Commands
The following commands require navigation to an enabled and configured port to which one or
more users are simultaneously connected. To get to the port, enter the following command.
--:- / cli-> cd access/

list_shared_session
List the users connected to the shared serial port.
Syntax:
--:-  cli-> list_shared_session

kill_shared_session
Terminate the connection of a user on the port. The user is returned to the cli-> prompt.
Syntax:
--:-  cli-> kill_shared_session 

Example:
--:-  cli-> kill_shared_session admin@139

sendmsg
Send a message to a user connected to the port.
Syntax:
--:-  cli-> sendmsg  

Example:

18     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

--:-  cli-> sendmsg admin@139 You are being
terminated.

show_databuf and show_appliance_databuf
View the data buffer files for the port. Data buffering must be enabled in the CAS Profile for
the port and the user must be authorized for data buffer management.
Syntax:
--:-  cli-> show_databuf

View the data logging for the appliance. Appliance Session Data logging must be enabled in
Events and Logs/Appliance Logging
Syntax:
--:- / cli -> show_appliance_databuf

The following commands are available for show data buffering:
•

Return - Scroll forward one line.

•

Ctrl + F - Scroll forward one window.

•

Ctrl + B - Scroll backward one window.

•

/pattern - Search foward in the file for the first line containing the pattern.

•

?pattern - Search backward in the file for the first line containing the pattern.

•

n - Repeat the search.

•

q - Quit.

cleandbuf and clean_appliance_databuf
Clear the data buffer. Data buffering must be enabled in the CAS Profile or the port and the
user must be authorized for data buffer management.
Syntax:
--:-  cli-> cleandbuf

Clear the data logging for the appliance. Appliance Session Data logging must be enabled in
Events and Logs/Appliance Logging
Syntax:
--:- / cli -> clean_appliance_dbuf

Chapter 2: CLI Command Set

19

CLI Equivalent Actions to Web Manager Checkbox Selection
NOTE: The following example procedure, which configures IPv6, illustrates the actions to use in the CLI to enable
or disable an option when a checkbox would be selected or deselected in the web manager. The sub-parameters
will be available after the option is enabled.

To configure IPv6 (example of how to perform the equivalent of web manager
checkbox selection/deselection):
1.

Log into the CLI and enter cd network/settings.
--:- / cli-> cd network/settings

2.

Enter show to view the status of IPv6 configuration.
--:- settings cli-> show
hostname = ACS6048
primary_dns = 110.126.129.4
secondary_dns =
domain = corp.tst.com
enable_ipv6 = no
enable_bonding = no
enable_ipv4_multiple_routing_tables = no

3.

Type set enable_ipv6= and press Tab to view the options for the parameter.
--:- ipv6 cli-> set enable_ipv6=
no yes

4.

Enter set enable_ipv6=no to disable IPv6.
--:- ipv6 cli-> set enable_ipv6=no

-orEnter set enable_ipv6=yes to enable IPv6.
--:- ipv6 cli-> set enable_ipv6=yes
5.

(Optional) Enter either of the following commands to enable subparameters.
**:- ipv6 cli-> set get_dns_from_dhcpv6=yes
**:- ipv6 cli-> set get_domain_from_dhcpv6=yes

6.

Enter show to verify the change.
**:- settings cli-> show
hostname = ACS6048
primary_dns = 110.126.129.4
secondary_dns =

20     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

domain = corp.tst.com
enable_ipv6 = yes
get_dns_from_dhcpv6 = no
get_domain_from_dhcpv6 = no
enable_bonding = no

7.

Enter commit.

21

3

Port Access and Configuration
Examples

By default, all serial ports and the AUX/Modem port are disabled. An administrator must enable
and configure the ports before anyone can use them. Configuration of ports differs based on the
type of connected device, which can be either a device console, a PDU or modem.
By default, all users can access all enabled and configured ports. The administrator must decide
whether to restrict user access to ports by the assignment of authorizations to user groups. A user
who is in an authorized group is referred to as an authorized user.
Some port configuration tasks are provided as examples of how to use the CLI. See the Cyclades
ACS 6000 Installation/Administration/User Guide for an overview of the tasks the administrator
must do to configure restricted access to ports. For more information about how to follow the
web manager procedures in the CLI, see Configuration Tasks Performed With the CLI on page 3.
This section describes the following tasks related to port access, configuration, power
management and where the tasks are performed in the CLI.
Table 3.1: Port Access and Configuration Tasks
Task

Where Performed

View information about the console server and
the connected devices

access show

Authorized users access enabled and configured ports

access connect
access//outlets

Authorized users manage power on outlets

-orpower_management/PDUs//outlet_table

Administrators configure ports connected to the
consoles of devices

ports
NOTE: See Chapter 3 for all Ports options.

22     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

View Information About the Console Server and Connected
Devices
When a regular user or an administrator enters show at the Access level, information about the
following appears in the format shown in :
•

The console server

•

The AUX/Modem port (if it is enabled and configured with the Power Profile)

•

The serial ports that user is authorized to access (if they are configured with the CAS or
Power Profile)

Table 3.2: Access Parameters
Field

Description

For Appliance
Name

Name assigned to the appliance (for example, ACS6048-1357908642)

Port

N/A

Type

N/A

Status

N/A

For Serial Port
Name

Either the default name [XX-XX-XX-p-n (where n=port_number)], an administratorassigned alias or an auto-discovered server name

Port

Number of the serial port

Type

Serial

Status

Idle / In-Use

For Power
Name

PDU ID (either the default name in the format XX-XX-XXPXX_n or an administratorassigned alias, such as myPDU)

Port

Number of the serial port/position on the chain

Type

PDU model

Status

Number of Outlets ON | Total outlets

Chapter 3: Port Access and Configuration Examples

Field

Description

For Outlets

Enter cd /outlets and enter show to see list of outlets and the actions that
can be taken (commands that can be executed) for each outlet as shown below.

Name

Either the default XX-XX-XXPXX_n_n or an administrator-assigned name

Port

PDU outlet number

Type

Outlet

Status

ON / OFF

Action

None

To view information about the console server and connected devices:
1.

Log into the CLI and enter cd access to change to the Access level.
--:- / cli-> cd access

2.

Enter show. Information about the console server and the ports the current user is
authorized to access appears.
--:- access cli-> show
Name Port Type Status
=====================================
ACS6016-0011223344
21-67-72-p-1 1 serial in-use
21-67-72-p-2 2 serial idle
21-67-72-p-4 4 serial idle
myPDU 3|1 PM8|15A 8|8
Type ls to see available sub-nodes
--:- access cli->ls
ACS6016-0011223344/
21-67-72-p-1/
21-67-72-p-2/
21-67-72-p-4/
myPDU/
Type show to see the content of the page
--:- access cli->

23

24     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

Connect to a Device Console Connected to a Serial Port
The following procedure is an example of how an administrator or an authorized user can
connect to a device console when the device is connected to a port that is enabled and
configured with the CAS Profile.
To connect to a device console connected to a serial port:
NOTE: The serial port must already be configured and enabled prior to this procedure. See Port Configuration
Examples on page 25.

1.

Log into the CLI and enter cd access to navigate to the Access level.
--:- / cli-> cd access
--:- access cli->

2.

Enter connect . If authentication is configured for the port, the
Password prompt appears when single sign-on is disabled.
--:- access cli-> connect 77-77-70-p-2
password:

NOTE: The connect command above shows a connection to a port that has an alias of 77-77-70-p-2.

3.

If prompted, enter the password for the port. The following prompt appears.
Type the hot key to suspend the connection: z

4.

Press Enter to continue. You are connected to the device that is connected to the port. The
window shows the initial display for the device (usually a console banner and login
prompt). An example is shown below.
Ubuntu 6.06.1 LTS fremont-techpubs ttyS2
fremont-techpubs login: fred
Password:
Last login: Tue Oct 2 13:09:04 2007 on :0
Linux fremont-techpubs 2.6.15-28-386 #1 PREEMPT Wed Jul 18 22:50:32 UTC
2007 i68
6 GNU/Linux
#

Accessing Serial Ports using ts_menu
The ts_menu is an application to facilitate connection to the serial ports. It displays a menu
showing the server names connected to the serial ports of the console server. You must
configure the login profile for the group that the users belong to as ts_menu.

Chapter 3: Port Access and Configuration Examples

25

ts_menu options
-u  [-l] [-ro] 
Table 3.3: ts_menu Parameters
Parameter

Description

-u 

Invokes ts_menu as the user named by . This requires a password to be
entered. The user only has access to authorized serial ports.

-l

Generates a list of ports the user can access. Port aliases are shown if defined.

-ro

Invokes ts_menu in read-only mode. You may connect in read-only mode to any port
you have access to.



If issued, produces a direct connection to that port. If you have no access rights to the
port or if the port does not exist, the application returns a console not found message
and terminates. The console port may be the port alias or the port number.

-p

Display TCP port.

-i

Display Local IP assigned to the serial port.

-u 

Username to be used in SSH/Telnet or Raw command.

-e <[^]char>

Escape character used to close the target session. The default escape character is

Ctrl-X.

To close the target session:
1.

Enter the escape character shown when you connect to the port.

2.

The menu with ports is displayed.

3.

Select the exit option to return to the shell prompt.

Manage Power for a Device Connected to an Outlet on a PDU
See cycle, on, off, lock and unlock on page 15 for how an administrator or any authorized user
can manage power on PDU outlets when the PDU is connected to a port that is enabled and
configured with the Power Profile.

Port Configuration Examples
The following examples show how an administrator can configure a port when a device
console is connected, assign the CAS profile, configure a port that is connected to a PDU and
assign the Power Profile.

26     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

To set up a console access service (CAS) port:
1.

Log onto the CLI as an administrator.
--:- / cli->

2.

Enter set_cas ports/serial_ports/ followed by a space and the number of the port you
want to configure (port 1 is used as an example).
--:- / cli-> set_cas ports/serial_ports/ 1

3.

Enter show to view the status of port 1.
Selected items: 1
Port: 1
enable_cisco_rj45_pin-out = no
status = enabled
speed = 9600
parity = none
data_bits = 8
stop_bits = 1
flow_control = none
Type ls to see available sub-nodes.
--:#- [serial_ports/physical] cli->ls
cas/
data_buffering/
alerts/
power/
Type show to see the content of the page.
--:#- [serial_ports/physical] cli->

4.

Enter set status=enabled, then enter show and save as shown to enable the configured
port and verify and save the configuration.
--:- serial_ports/physical cli-> set status=enabled
--:- serial_ports/physical cli-> show
--:- serial_ports/physical cli-> save

To enable a power management port:
1.

Log onto the CLI as an administrator and enter set_power ports/serial_ports/  to select a port with a PDU connected (port 3 is used as an example).
--:- / cli-> set_power ports/serial_ports/ 3

Chapter 3: Port Access and Configuration Examples

2.

Enter show to view the configuration of port 3.
--:- serial_ports/physical cli-> show
Selected items: 3
Port: 3
enable_cisco_rj45_pin-out = no
status = enabled
speed = 9600
parity = none
data_bits = 8
stop_bits = 1
flow_control = none
Type ls to see available sub-nodes
--:- serial_ports/physical cli->

3.

Enter set status=enabled then enter save to set the Serial_Profile to Power, enable the
port and commit the changes.

4.

Enter show to verify the configuration.
--:- serial_ports cli-> show
Port Device Name Profile Settings
==== ====== ================== ======= =========================
1 ttys1 ACS6016-0088664422 cas 9600_8N1_telnet-ssh_local
2 ttys2 21-67-72-p-2 cas 9600_8N1_telnet-ssh_local
3 ttys3 power cas 9600_8N1_telnet-ssh_local
4 ttys4 21-67-72-p-4 cas 9600_8N1_telnet-ssh_local
5 ttys5 21-67-72-p-5 cas 9600_8N1_telnet-ssh_local
6 ttys6 21-67-72-p-6 cas 9600_8N1_telnet-ssh_local
7 ttys7 21-67-72-p-7 cas 9600_8N1_telnet-ssh_local
8 ttys8 21-67-72-p-8 cas 9600_8N1_telnet-ssh_local
9 ttys9 21-67-72-p-9 cas 9600_8N1_telnet-ssh_local
10 ttys10 21-67-72-p-10 cas 9600_8N1_telnet-ssh_local
11 ttys11 21-67-72-p-11 cas 9600_8N1_telnet-ssh_local
12 ttys12 21-67-72-p-12 cas 9600_8N1_telnet-ssh_local
13 ttys13 21-67-72-p-13 cas 9600_8N1_telnet-ssh_local
14 ttys14 21-67-72-p-14 cas 9600_8N1_telnet-ssh_local
15 ttys15 21-67-72-p-15 cas 9600_8N1_telnet-ssh_local
16 ttys16 dial-in 38400

27

28     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

Type ls to see available sub-nodes

29

4

CLI Overview for Administrators

This chapter describes using the Command Line Interface (CLI) for administrators. Only
administrators and authorized users can access the commands listed in this chapter. These
procedures assume you have logged into the CLI as an administrator and are at the --:- / cli->
prompt.
NOTE: In the tables that show output from the show command, when an option that is followed by an equal sign (=)
is left blank, that option is not assigned a value by default.

System
1.

Enter cd system to navigate to the System level.
--:- / cli-> cd system

2.

Enter ls to view the available options.
--:- system cli-> ls
security/
date_and_time/
help_and_language/
general/
boot_configuration/
information/
usage/

3.

Enter show followed by an option name to view information about each option.
--:- security cli-> show security_profile

30     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

System/Security
Enter cd security to navigate to the security level.
--:- / cli-> cd system/security
Table 4.1: System/Security Options
System Navigation Tree
security_profile
idle_timeout=
port_acess_per_user_group_authorization=
rpc=
bootp_configuration_retrieval
enabled=
interface=
enable_live_configuration_retrieval=
security_profile=
security_profile/
custom
enable_telnet_service=
enable_ftp_service=
enable_snmp_service=
enable_ipsec=
answer_icmp_message=
ssh_version=
ssh_tcp_port=
ssh_allow_root_access=
enable_http_session=

Chapter 4: CLI Overview for Administrators

System Navigation Tree
http_port=
enable_https_session
https_ssl_version=
https_port=
https_minimum_cipher_suite_level=
redirect_http|https=
dsview
all_appliance_to_be_managed_by_dsview=
fips_140
enable_fips_140-2_module=

System/Date and Time
Enter cd system/date_and_time to navigate to the date_and_time level.
--:- / cli-> cd system/date_and_time
Table 4.2: Date and Time Options
Date and Time Navigation Tree
date_and_time
date_and_time
settings
manual
day=
hour=
minute=
month=
second=

31

32     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

Date and Time Navigation Tree
year=
time_zone
predefined
zone=set

System/Help and Language
Enter cd system/help_and_language to navigate to the online_help level.
--:- / cli-> cd system/help_and_language

To set the online help URL:
Perform this procedure if you have downloaded the online help files to a web server that is
accessible to the console server.
1.

Enter the following command.
--:- / cli> cd system/help_and_language/

2.

Enter the following command.
--:- help_and_language cli> set url=

A line similar to the following appears.
**:- help_and_language cli>

3.

Save your settings.
**:- help_and_language cli> commit.

Table 4.3: Help and Language Options
Help and Language Navigation Tree
appliance_language=
url=

System/General
Enter cd system/general to navigate to the login_banner level.
--:- / cli-> cd system/general

To set the login banner:
1.

Enter the following command.

Chapter 4: CLI Overview for Administrators
--:- / cli> cd system/general/

2.

Enter the following command.
--:- general cli-> set enable_login_banner=yes
**:- general cli> set login_banner=

A line similar to the following appears.
**:- general cli>

3.

Save your settings.
**:- general cli> commit.

System/Boot Configuration
Enter cd system/boot_configuration to navigate to the boot_configuration level.
--:- / cli-> cd system/boot_configuration
Table 4.4: System/Boot Configuration Options
Boot Configuration Navigation Tree
boot mode=
console_speed=
eth0_mode=
eth1_mode=
watchdog_timer=
boot_mode/
flash
image=image

System/Information
1.

Enter cd system/information to navigate to the Information level.
--:- / cli> cd system/information/

2.

Enter show to view the system information.

System/Usage
Enter cd system/usage to navigate to the Usage level.
--:- / cli> cd system/usage/

33

34     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

Table 4.5: System/Usage Options
Usage Navigation Tree
flash usage
memory

Network
1.

Enter cd network to navigate to the Network level
--:- / cli-> cd network/

2.

Enter ls to view the list of available options.
settings/
devices/
ipv4_static_routes/
ipv6_static_routes/
hosts/
firewall/
ipsec(vpn)/
snmp/

Network/Settings
1.

Enter cd network/settings to navigate to the Network settings level.
--:- / cli-> cd network/settings/

2.

Enter show to view the list of available options.

Table 4.6: Network Options
Network Navigation Tree
settings
domain=
enable_bonding=
enable_ipv6=
hostname=

Chapter 4: CLI Overview for Administrators

35

Network Navigation Tree
primary_dns=
secondary_dns=
enable_ipv6=
get_dns_from_dhcpv6=
get_domain_from_dhcpv6=
enable_ipv4_multiple_routing_tables=

Network/IPv4 and IPv6
IPv4 addresses are always enabled. An administrator can also enable IPv6 addresses at the
appliance_settings/network/ipv6 level. A procedure to enable IPv6 is used as an example in
CLI Equivalent Actions to Web Manager Checkbox Selection on page 19.
Table 4.7: Network/IPv4 and IPv6 Options
IPv4 and IPv6 Navigation Tree
ipv4_static_routes
default_3
gateway=
interface=
metric=
ipv6_static_routes

Network/Devices
The procedure to configure a static IP address for the primary Ethernet interface is usually
performed during installation so that administrators have a fixed IP address for access to the
web manager and can finish configuration.
To configure a IPv4 or IPv6 static IP address:
NOTE: This procedure configures either an IPv4 or IPv6 static IP address for the ETH0 (eth0) or the ETH1 (eth1)
port. You can configure an IPv6 static IP address only if IPv6 is enabled.

36     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

1.

Enter cd network/devices/ /settings to navigate to the Settings level for the
desired interface.
--:- / cli-> cd network/devices/eth0/

2.

Enter set ipv< 4|6> _method=static to set the method to static for IPv4 or IPv6.
**:- eth0 cli-> set ipv4_method=static

3.

Enter set ipv< 4|6> _address= ipv< 4|6> _mask= to set the IP
address and subnet mask, then enter commit to save the change.
--:- eth0 cli-> set ipv4_address=172.26.31.10 ipv4_mask=255.255.255.0
**:- eth0 cli-> commit

4.

Enter show to view the changes.
--:- eth0 cli-> show

Table 4.8: Network/Devices Options
Devices Navigation Tree
devices
eth0
ipv4_method=
ipv6_method=
mode=
status=
eth1
ipv4_method=
ipv_6method=

Network/Hosts
The following procedure describes how to add a host to the hosts table.
To add a host to the host table:
1.

Enter cd network/hosts to navigate to the Hosts level.

--:- / cli-> cd network/hosts
2.

Enter show to view the current host settings.
--:- hosts cli-> show

Chapter 4: CLI Overview for Administrators

37

127.0.0.1
ip: 127.0.0.1
hostname: localhost
alias:
127.0.0.1/

3.

Type add then press Return.
--:- hosts cli-> add
--:#- [hosts] cli-> ls
ip =
hostname =
alias =
--:#- [hosts] cli->

4.

Enter set hostname= ip= to add the name of a host and the IP
address for the host.

NOTE: Each parameter that follows the add command is separated by a space.

--:#- [hosts] cli-> set hostname=sharedacs6000 ip=172.26.31.164

5.

Enter commit.
--:#- [hosts] cli-> save

6.

Enter show to verify the changes took place and to view the new host entry.
--:- hosts cli-> show
127.0.0.1
ip: 127.0.0.1
hostname: localhost
alias:
172.26.31.164
ip: 172.26.31.164
hostname: sharedacs6000
alias:
127.0.0.1/add
172.26.31.164/

7.

Enter cd /settings to navigate to the level where you can perform additional
configuration of the host entry.

--:- hosts cli-> cd 172.26.31.164/settings
8.

Enter show to view the additions to the host table and the Settings option.

38     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

--:- 172.26.31.164 cli-> show
ip: 172.26.31.164
hostname = sharedacs6000
alias =
Table 4.9: Network/Hosts Options
Hosts Navigation Tree
hosts
127.0.0.1
alias=
hostname=

Network/Firewall
Enter cd network/firewall to navigate to the firewall level.
--:- / cli-> cd network/firewall
NOTE: To set a rule, you must enable the interface, set the rule for the interface and physically connect the
interface to the network.
Table 4.10: Network/Firewall Options
Firewall Navigation Tree
firewall
ipv
ipv4_filter_table
FORWARD
INPUT
OUTPUT
ipv6_filter_table
FORWARD
INPUT
OUTPUT

Network/IPSec(VPN)
Enter cd network/ipsec(vpn) to navigate to the ipsec(vpn) level.

Chapter 4: CLI Overview for Administrators

39

--:- / cli-> cd network/ipsec(vpn)
Table 4.11: Network/IPSec(VPN) Options
IPSec(VPN) Navigation Tree
ipsec(vpn)

Network/SNMP
Enter cd network/snmp to navigate to the snmp level.
--:- / cli-> cd network/snmp
Table 4.12: Network/SNMP Options
SNMP Navigation Tree
snmp
public_v1|v2/
oid=
permission=
source=

Wiz command
The wiz command allows administrators to easily and quickly perform the initial network
configuration of the eth0.
At the command prompt at the / level, enter wiz to view the current IP configuration. To change
the IP configuration, press Tab to move through the parameters, and press Esc + Tab to edit the
selected parameter. When you are finished, enter yes to confirm that all parameters are correct
and to save the new parameters.
--:- / cli-> wiz
Current IPv4 address: 172.26.30.249
Current IPv6 address:
eth0:
device_status = enabled
ipv4_method = dhcp
ipv4_address = 192.168.160.10
ipv4_mask = 255.255.255.0
ipv4_default_gateway =

40     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

ipv6_method = ipv6_address_unconfigured
ipv6_address =
ipv6_prefix_length =
ipv6_default_gateway =
MAC Address: 00:e0:86:21:67:72
dns:
primary_dns = 172.26.29.4
secondary_dns =
domain = corp.avocent.com
hostname = ACS6016-0011223344
Some basic and useful keys are:
- tab (once/twice) - shows the next possible commands/option(s)
- esc tab - gets the current parameter value for editting
Other hints:
- Use backslash '\' to escape spaces, '\' and other control
characters when assigning values to parameters.
Current IPv4 address: 172.26.30.249
Current IPv6 address:
eth0:
device_status (disabled, enabled) [enabled]:

Ports
Enter cd ports to navigate to the Ports level.
--:- / cli-> cd ports
Table 4.13: Ports Options
Ports Navigation Tree
serial ports
auxiliary ports
ttyA1
cas_profile
auto_discovery
settings

Chapter 4: CLI Overview for Administrators

Ports Navigation Tree
auto_discovery_timeout_(seconds)=
default_speed_on_auto_discovery_failure=
probe_speed_115200=
probe_speed_1200=
probe_speed_19200=
probe_speed_230400=
probe_speed_2400=
probe_speed_38400=
probe_speed_4800=
probe_speed_57600=
probe_speed_9600=
probe_timeout_(seconds)=
pool_of_ports
pool_name=
pool_tcp_port_alias=
pool_ipv4_alias=
pool_ipv4_alias_interface=
pool_ipv6_alias=
pool_ipv6_alias_interface=
pool_members=
dial-in_profile
secure_dial-in
callback_users
settings
log_in_to_appliance=

41

42     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

Ports Navigation Tree
otp_login_authentication=
ppp_connection=
ppp|pap_authentication=

Table 4.14: Serial Port Commands
Command

Summary

set_cas

Edits the command to configure a list of serial ports with the CAS profile. Syntax: set_cas,  This
command has five sub-nodes: physical, cas, data_buffering, alerts and
power.

set_dial_in

Edits the command to configure one serial port with the Dial-In profile.
Syntax: set_dialin

set_power

Edits the command to configure a list of serial ports with the Power profile. Syntax: set_power, []
This edit has two sub-nodes: physical and power.

clone_ports

Copies the configuration from one port to a list of serial ports. Syntax:
clone_ports

reset_port_to_factory

Resets the serial ports to factory configuration. (This is disabled for
CAS profile.) Syntax: reset_port_to_factory,
[]

enable_ports

Enables serial ports. Syntax: enable_ports,
[]

disable_ports

Disables serial ports. Syntax: disable_ports,
[]

Example of how to set a list of serial ports 2,5 and 6 with the CAS Profile and enable
the status:
--:- serial_ports cli-> cd /ports/serial_ports
--:- serial_ports cli-> set_cas 2,5,6
--:#- [serial_ports/physical] cli-> set status=enabled
--:#- [serial_ports/physical] cli-> show
Selected items: 2|5|6
Port: 2
enable_cisco_rj45_pin-out = no

Chapter 4: CLI Overview for Administrators

43

status = enabled
speed = 9600
parity = none
data_bits = 8
stop_bits = 1
flow_control = none
Type ls to see availables sub-nodes.
--:#- [serial_ports/physical] cli-> ls
cas/
data_buffering/
alerts/
power/
Type show to see the content of the page.
--:#- [serial_ports/physical] cli->save
--:- serial_ports cli->

To copy the configuration from serial port 5 to ports 10 and 15:
--:- serial_ports cli-> clone_ports 5
--:#- [serial_ports] cli-> show
Copy configuration from: 5
copy_configuration_to =
--:#- [serial_ports] cli-> set copy_configuration_to=10,15
--:#- [serial_ports] cli-> save
--:- serial_ports cli->

Auxiliary ports
Enter cd ports/auxiliary_ports to navigate to the auxiliary ports level.
--:-cli-> cd /ports/auxiliary_ports/

If an internal modem is factory installed, the only available serial_profile option is Dial-in. If an
internal modem is not installed, either an external modem or a PDU can be connected to the
port and a second serial_profile option, Power, is available.
Appliance with an internal modem
When an internal modem is factory installed, the port name is ttym1. To enable the internal
modem:
--:-cli-> cd /ports/auxiliary_ports/

44     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

--:- auxiliary_ports cli-> show
Device Name: ttyM1
status = disabled
speed = 38400
init_chat = "" \d\d\d+++\d\d\dATZ OK
ppp_address = no_address
ppp_authentication = none
chap-interval = 0
chap-max-challenge = 10
chap-restart = 3
ppp_idle_timeout = 0
--:- auxiliary_ports cli->set status=enabled
--:- auxiliary_ports cli->commit

Appliance without an internal modem:
If no internal modem is installed, the port name is ttya1.
Enter the commands: set_dial-in or set_power to configure the auxiliary port.
--:- / cli-> cd ports/auxiliary_ports/
--:- auxiliary_ports cli-> show
Port Device Status Profile
===== ====== ======== ============
ttyA1 ttyA1 disabled unconfigured
Type ls to see availables sub-nodes.
--:- auxiliary_ports cli->

Pluggable Devices
Enter cd pluggable_devices to navigate to the pluggable_devices level.
--:- / cli-> cd pluggable_devices

Table 4.15: Pluggable Devices Options
Pluggable Devices Navigation Tree
device_name
device_type
card
device_info

Chapter 4: CLI Overview for Administrators

45

Authentication
Enter cd authentication to navigate to the authentication level.
--:- / cli-> cd authentication
NOTE: Kerberos does not work unless the administrator copies the /etc/krb5.keytab file from the Kerberos server
and overwrites the /etc/krb5.keytab file in the console server.

Table 4.16: Authentication Options
Authentication Navigation Tree
appliance_authentication
authentication_servers
radius
tacacs+
ldap(s)/ad
kerberos
nis
dsview

Users
Enter cd users to navigate to the users level.
--:- / cli-> cd users

Table 4.17: Users Options
Users Navigation Tree
local_accounts
user_names
root
admin

46     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

Users Navigation Tree
password_rules
password enforcement
default expiration
authorization
groups
admin
appliance-admin
user

To add a user and password:
1.

Enter cd users/local_accounts/user_names to navigate to the user_names level.
--:- / cli-> cd users/local_accounts/user_names

2.

Enter add. Then enter set with the parameters all on one line separated by spaces as shown.
--:- user_names cli-> add
--:#- [user_name] cli-> set user_information/ user_name=fred
password=smith123abc confirm_password=smith123abc
--:#- [user_names] cli->

3.

Enter save.
--:#- [user_names] cli-> save

4.

Enter show to verify that the new user has been added.
--:#- [user_names] cli-> show

Syslog
Enter cd appliance_settings/syslog to navigate to the syslog level.
--:- / cli-> cd appliance_settings/syslog

Chapter 4: CLI Overview for Administrators
Table 4.18: Syslog Options
Syslog Navigation Tree
remote_server_ipv4
server_ip_or_hostname (to specify multiple servers, separate the entries with commas)
remote_server_ipv6
server_ip_or_hostname (to specify multiple servers, separate the entries with commas)
appliance_console
root_session

Events_and_Logs
Enter cd events_and_logs to navigate to the events_and_logs level.
--:- / cli-> cd events_and_logs
Table 4.19: Events_and_Logs Options
Events_and_Logs Navigation Tree
event list
event destinations
syslog
snmp trap
sms
email
dsview
data_buffering
local_data_buffering_settings
segment_size_(kbytes)=
spare_segments=
nfs_data_buffering_settings
nfs_server=

47

48     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

Events_and_Logs Navigation Tree
nfs_path=
segment_size_(kbytes)=
spare_segments=
syslog_data_buffering_settings
syslog_facility=
sensors
current_temperature:(deg_c, display only)
maximum_temperature_(deg_c)=
maximum_temperature_threshold_(deg_c)=(positive integer between 0 and 4)
minimum_temperature_(deg_c)=
minimum_temperature_threshold_(deg_c)=(positive integer between 0 and 4)

Power Management
The Power Management Options are described in the table below.
Table 4.20: Power Management Options Descriptions
Option

Description

pdus

Allows an authorized user to reboot, restore factory default settings or to rename
PDU(s). Also allows the authorized user to view information about each PDU, monitor
sensors, clear sensor values, set up syslogging of events related to the PDU, configure
an alarm and the LED display mode, and to manage outlets on the PDU.

outlet_groups

Lists all configured outlet groups that the current user is authorized to manage (to manage outlet groups, the user must be in a user group that is authorized to manage all the
outlets in the outlet group). An administrator can configure outlet groups.

To rename a PDU:
1.

Log onto the CLI as an administrator and enter cd power_management/pdus to navigate
to the pdus level.
--:- / cli-> cd power_management/pdus

2.

Type rename and press Tab Tab to expand the parameters.
--:- pdus cli-> rename  

Chapter 4: CLI Overview for Administrators

3.

49

Enter set newpdu_id=.
--:#- [pdus] cli-> set new_pdu_id=mypdu
--:#- [pdus] save

NOTE: See the Cyclades ACS 6000 Installation/Administration/User guide for how to perform other authorized
PDU configuration options.

To manage power for a selected outlet:
See cycle, on, off, lock and unlock on page 15 for how to manage power at the power_
management level.

Active Sessions Information
The Active Session information fields are described in the table below. An authorized user can
kill an active session with the Kill command.
Table 4.21: Active Sessions Field Descriptions
Field

Description

user

Logged in user

client_ip

Source of the connection

creation_time

Time of the session creation

session_type

Type of session (console, http)

connection_type

Type of connection (cli, wmi - that is, Web Manager)

target_name

Target name or alias if session is an access session

id

Session ID

parent id

Parent ID if session is a subsession

To view and kill Active_Sessions:
1.

From the / level CLI prompt, enter cd active_sessions.
--:- / cli-> cd active_sessions
--:- active_sessions cli->

2.

Enter show. Information displays as shown about all active sessions.
--:- active_sessions cli-> show
37
user: admin

50     Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

client_ip: none
creation_time: Tue Dec 18 03:31:01 2007
session_type: console
connection_type: cli
target_name:
id: 37
parent_id:
--:- active_sessions cli->

3.

To kill a session (if authorized), enter kill followed by the session number.

51

APPENDICES

Appendix A: Enabling Firmware Upgrades When the Boot
Image is not in Flash
To enable firmware upgrades when the boot image is not in Flash:
1.

Connect to the console of the console server as root.
Welcome to ACS6000 .
Type help for more information.
--:- / cli->

2.

Enter shell. A warning appears followed by the root prompt.
--:- cli-> shell
WARNING: Improper use of shell commands could lead to data loss,
the deletion of important system files or other unexpected result.
Please double-check your syntax when typing shell commands.
[root@ACS6048-3131313131 ~]#

3.

Enter recover-flash.sh --factory_default --doformat.
[root@ACS6048-3131313131 ~]# recover-flash.sh --factory_default
--doformat
[root@ACS6048-3131313131 ~]#

The Flash memory is formatted, and the version of firmware in memory is stored in
Flash. The command prompt reappears.
4.

Enter reboot.
[root@ACS6048-3131313131 ~]# reboot

When the system reboot completes, the web manager supports firmware upgrades.

52

Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

Appendices

53

Appendix B: Migration CLI
The Migration CLI is a tool that allows you to configure an ACS 6000 console server that is
running scripts based in the ACS advanced console server. For full configuration and
management commands, it is recommended you use the ACS 6000 console server’s CLI.
NOTE: References to an ACS advanced console server in this section refer to any advanced console server other
than the ACS 6000 console server.

In the ACS 6000 console server, the login profile for the user “root” goes directly to the shell
prompt. This will allow the root user to run Migration CLI commands out of the ACS 6000
console server. A new group, “login-profile-shell,” is created with only root as a member. To
run commands based from an ACS advanced console server, a root user should type CLI before
the command.
Access rights
The access rights on the ACS 6000 console server are based on authorization groups. The
administrator configures the serial ports the group can access. To allow you to configure access
rights, the following table displays authorization groups that will be created on the ACS 6000
console server when using the Migration CLI.
Table B.1: Access Rights Groups
Group

Members

Permissions

cli_mus_ttySxx

Users who can open a second
session to a serial port.

Access to a serial port in a mulisession (read/write or read only)

cli_power_ttySxx

Users who have power control in a
serial port.

Power control (on/off/cycle) of
outlets merged to a serial port.

cli_access_ttySxx

Users who can access a serial port in
a single session.

Access to a serial port in a single
read/write session.

cli_pmd_




Power control of the outlet.

Exceptions
This section will list all ACS advanced console server CLI commands not available in the
Migration CLI for the ACS 6000 console server. For a list of available commands, see the
Cyclades ACS Installation/Administration/User Guide.
The following commands or values are not supported by the Migration CLI:

54

Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide
Table B.2: Commands Not Supported by the Migration CLI
Command

Value or Descriptions

administration
backupconfig loadfrom sd

N/A

backupconfig saveto sd

N/A

upgradefw checkum

N/A

application
connect

N/A

pm

N/A

view

N/A

config administration bootconf
bootype

bootp/both/ftp

flashtest

full/skip

maxevents



ramtest

full/quick/skip

config administration notifications
addemail

N/A

addpager

N/A

addsnmptrap

N/A

alarm

N/A

delete

N/A

edit

N/A

config application pmdconfig general
add

N/A

delete

N/A

config application terminalmenu
add

N/A

Appendices

Command

Value or Descriptions

delete

N/A

menutitle

N/A

config network hostSettings
secipaddress



secsubnetmask



mtu

N/A

config physicalports access
users/groups

accepts only list of usernames

authtype

assume local

termshell



logintimeout



config physicalports databuffering
mode

cir/lin

showmenu

file/fileanderase/no/noerase/yes

syslogsize



config physicalports general
pmsessions

none/ssh/ssh_telnet/telnet

protocol

bidirectionaltelnet, consoleraw, cslip, local,
rawsocket, slip, sshv1, sshv2, telnet

config physicalports multiuser
users

accepts only list of users

sniffmode

in/inout/no/out

config physicalports other
SSHexitkey



banner



host



55

56

Cyclades™ ACS 6000 Advanced Console Server Command Reference Guide

Command

Value or Descriptions

sttyoptions



tcpkeepalive



terminaltype

aixterm, att6386, linux-lat, vt100, vt320,
xtermcolor, ansi, ibm3151, scoansi, vt102,
vt52, at386, linux, sun, vt220, xterm

winems

no/yes

idletimeout



config physicalports power management
enableIPMI

N/A

disableIPMI

N/A

key

N/A

server

N/A

config security
addgroup/delgroup

N/A

config security adduser
shell



comments



config security profile custom
ports auth2sport

no/yes

ports bidirect

no/yes

ports raw2sport

no/yes

ports ssh2sport

no/yes

ports telnet2sport

no/yes

ssh ssh_x509

no/yes

config virtualport
config ipmi



Appendices

Command

Value or Descriptions

security authentication
authtype

Otp, Otp/Local

pppauthtype

Otp, Otp/Local

timeout
-t

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Title                           : My Document
Author                          : ddefurio
Producer                        : MadCap Flare V7
Subject                         : 
Modify Date                     : 2011:04:08 09:05:39-05:00
Create Date                     : 2011:04:08 09:05:39-05:00
Page Count                      : 73
Language                        : en-us
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools

Navigation menu