BALOGH LMB-7013 Compact Reader for Tag Identification User Manual Appendix 1 General presentation
BALOGH Compact Reader for Tag Identification Appendix 1 General presentation
BALOGH >
Users Manual
HYPER X PRODUCT ENHANCED COMPACT READER LMB_6000 and LMB_7000 INSTALLATION MANUAL Rédigé par / Written by : Philippe GOBRECHT Date Signature Approuvé par / Approved by : Bruno WIEDEMANN Date Signature Autorisé par / Authorized by : Philippe GOBRECHT Date Signature / Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 1/27 EVOLUTIONS SUCCESSIVES /SUCCESSIVE CHANGES INDICE / REVISION INDEX DATE MODIFIE PAR / CHANGED BY OBJET / DESCRIPTION 06/2001 Ph. GOBRECHT Création 09/2002 Ph. GOBRECHT Addition of FCC notice and CE Notice Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 2/27 TABLE OF CONTENTS 1. FUNCTIONS AND PERFORMANCE ..................................................................................................................... 4 2. TECHNICAL CHARACTERISTICS....................................................................................................................... 5 3. THE POWER SUPPLY.............................................................................................................................................. 6 4. VERIFICATION OF THE READER ....................................................................................................................... 7 5. INSTALLATION ........................................................................................................................................................ 8 5.1. 5.2. 5.3. LMB_6010 FAMILY ............................................................................................................................................. 8 LMB_6030 FAMILY ............................................................................................................................................ 8 LMB_7000 FAMILY ............................................................................................................................................. 8 6. EXTERNAL CONNECTIONS.................................................................................................................................. 9 7. INSTALLATION AND CONNECTION PROCEDURES FOR THE ASYNCHRONOUS LINKS................. 11 7.1. 7.2. 7.3. 7.4. CABLE TO BE USED FOR SERIAL LINK RS422 OR RS485 ..................................................................................... 11 LINE TERMINATION ............................................................................................................................................ 11 ELECTRICAL CONNECTIONS ................................................................................................................................ 11 NETWORKING ..................................................................................................................................................... 11 8. OPEN COLLECTOR INTERFACE....................................................................................................................... 13 9. THE OUTPUTS (JR3).............................................................................................................................................. 15 10. THE INPUTS (JR4) ............................................................................................................................................. 16 11. OPERATING FREQUENCY CHANNEL......................................................................................................... 17 12. ADJUSTMENT OF THE READING RANGE ................................................................................................. 18 12.1. 12.2. 13. 1. 14. VERIFICATION OF THE THE POSITION OF THE ADJUSTMENT OF THE READING RANGE : ........................................ 18 MODIFICATION OF THE POSITION OF THE READING RANGE : ............................................................................... 18 ORIENTATION OF THE ANTENNA .............................................................................................................. 19 FCC NOTICE............................................................................................................................................................ 20 CE NOTICE ......................................................................................................................................................... 21 APPENDIX 1 : GENERAL PRESENTATION .............................................................................................................. 22 APPENDIX 2 : SERIAL LINK ........................................................................................................................................ 23 APPENDIX 3 : OPEN COLLECTOR OUTPUT ........................................................................................................... 24 APPENDIX 3 : OPEN COLLECTOR OUTPUT ............................................................................................................ 25 APPENDIX 4 : INPUTS / OUTPUTS............................................................................................................................... 26 APPENDIX 4 : INPUTS / OUTPUTS............................................................................................................................... 27 Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 3/27 1. FUNCTIONS AND PERFORMANCE Hyper X system uses a reader which emits a microwave signal to an identification area . The range of this identification area varies from a few centimeters to several meters. When a tag enters this zone, it modulates this radiation, thereby sending its code back to the reader, which then processes the received signal and extracts the code. The LMB reader contains all the functional parts of the reading unit. For the LMB_6000 readers, the antenna is integrated inside the reader. The LMB_7000 readers use an external monolithic antenna such as AT1, AT2, AT3 or AT5. The principal functions are : • Reading distance from 2 to 8m depending on model • Reading distance adjustment by selection of 3 positions. • Directivity of the microwave signal : - Identification relatively insensitive to environment - Adjustable beam - Installation of reading antenna against metal walls without range reduction • Simultaneous identification of 5 tags in 1 second - Several tags can be present in identification zone, intentionally or not - Identification of the tag in all positions : recto/verso ; horizontal/vertical • Coexistence of several readers in same area : 31 in Europe and 119 in US Precautions: - Metallic surfaces or persons coming between tags and the reading antennas create shadow zones in the identification area. - The proximity of a tag to a metallic surface or a person (<5mm) reduces the reading distance. Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 4/27 2. TECHNICAL CHARACTERISTICS Operating temperature Storage temperature Relative humidity Protection level Power supply Frequency band Number of reading channels Data rate Error Detection Code error rate Reading failure rate Reading adjustment -20°C to +70°C -25°C to +80°C 90% without condensation IP40 or IP56 with waterproof case 12 Vdc to 24Vdc- 12W 2,450 GHz 31 for Europe or 119 for US 30 000 bauds HDLC 1 E-7 1 E-4 (normal conditions of use) 3 positions LMB_6012 LMB_6013 LMB_6033 LMB_6034* LMB_6035* Dimensions in mm 263x178x32 263x178x32 297x297x85 297x297x85 297x297x85 Weight 1,5kg 1,5 kg 5,2kg 5,2kg 5,2kg EIRP 10mW 75mW 75mW 200mW 350mW Range 2m 3m 5m 5m 5m internal internal internal internal internal Directivity 90° x 90° 90° x 90° 45° x 45° 45° x 45° 45° x 45° Waterproof case Optional Optional Yes Yes Yes Antenna LMB_7012 LMB_7013 LMB_7023 LMB_7033 Dimensions 297x297x85 297x297x85 297x297x85 297x297x85 in mm Weight 5,2kg 5,2kg 5,2kg 5,2kg EIRP 10mW 75mW 75mW 75mW Range 2m 3m 5m 5m Antenna External AT1 External AT1 External AT2 External AT3 Directivity 90° x 90° 90° x 90° 45° x 45° 45° x 45° Waterproof case Yes Yes Yes Yes * : not available in US EIRP :Equivalent Isotropic Radiated Power Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 5/27 3. THE POWER SUPPLY The reader supply must be between 12Vdc and 24Vdc. With 12Vdc, the current is less than 1A With 24Vdc, the current is less than 0.6A The extreme limits for the power supply are 11Vdc to 28Vdc : it’s very important to respect these limits for correct operation of the readers and to avoid damage. A led « low voltage », near the power supply connector, indicates the voltage supply is less than 11Vdc. At the time of the “low voltage” detection, the reader enables a timer of about twenty seconds. After this time, the reader tries to power on. If the voltage is right, the reader will turn on, if the voltage is still too low, it enables the timer again and so one. Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 6/27 4. VERIFICATION OF THE READER This verification is made during the powering on of the reader with all the interfaces and the inouts/Outputs disconnected. General state Bi-color indicator DN02 Indicator Low voltage DT06 State of TTL link DR09 State of Inputs and Outputs DR03 DR04 DR05 DR06 TTL link RS link JR02 JR01 1 2 3 4 5 1 2 3 4 5 JT01 JK01 JR04 1 2 3 1 2 3 4 Inputs State of serial link DR07 DR08 JR03 1 2 3 4 5 6 Outputs Buzzer Displays UN17 - UN18 We can sume the successive states : Phase 1 : • Buzzer emits a bip during 1s • Indicator light DR09 red on during 4s • Displays UN17 and UN18 with “P1” during 4s • Bi-color Indicator light DN02 red on during 5s Phase 2: • Displays UN17 and UN18 with “PE” during 1s Phase 3 : • Displays UN17 and UN18 off • Bi-color Indicator light blinks green 0,5s on and 0,5s off. Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 7/27 5. INSTALLATION 5.1. LMB_6010 family The reader is made of a solid aluminium cast on which the circuits boards are fixed and a plastic radome fixed with two screws. To open the reader : - Unscrew and remove the two screws at each end of the reader - Remove the radome The reader must be mounted on a support (wall...) with 4 screws (maximum diameter is 6mm) at the corners of a rectangle of 151 x 241 mm. The procedure for closing the reader is the reverse of that for opening. 5.2. LMB_6030 family The LMB_6030 family uses the same base as the LMB_6010, but has a different antenna and a waterproof case. To open the reader : - Remove the black plastic bushings located in the 4 angles of the grey waterproof case. - Use the special tool and turn the 4 locking gear ( ¼ of turn) - Remove the plastic cover of the waterproof case. 5.3. LMB_7000 family The LMB_7000 family uses the same base as the LMB_6010 with an external monolithic antenna and a waterproof case. To open the reader : - Remove the black plastic bushings located in the 4 angles of the grey waterproof case. - Use the special tool and turn the 4 locking gear ( ¼ of turn) - Remove the plastic cover of the waterproof case. Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 8/27 6. EXTERNAL CONNECTIONS Red push Select/Save Black push Display/Change bi-color Led Black push Reset Led “ low Voltage” TTL Link JK01 1 2 3 RS Link JR02 JT01 JR04 JR03 JR01 1 2 3 4 5 1 2 3 4 5 1 2 34 1 2 3 4 56 In Out JK01 Display Analog measurement Pin Buzzer JR01 Pin Name RS-232 RS-422 O1 TX TX+ O2 -TX3 O3 -RX+ O4 RX RX5 GND GND GND Nom Ch I GND ChQ RS485 +V -V --GND JR02 JT01 Pin Power supply 12Vdc to 24Vdc Connector with 2 points Pin Name Valim 0V Nom ISO2 WIEGAND DATA “1” OC1 STROBE DATA”0” OC2 MDATA -OC3 PRES BADGE Valim Valim Valim GND GND GND consumption 1 A max / 12Vdc. Voltage input (Valim) between 11Vdc min and 28Vdc max. The red and black push buttons are used to configure the reader : The procedure to display or change parameters is : ☞ 1- select the function : red push-button Select ☞ 2- display the function : red push button Change ☞ 3- save the parameter : red push-button Save Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 9/27 JK01 is a connector to measure the analog signal receive by the reader. These test points allow measuring the noise with a scope and therefore the quality of the electromagnetic environment for the installation. These test points allow measuring the analog signals from the tag. JT01 : is the connector for the supply voltage. A female connector with screw (Phoenix with 2 points pitch 5.08mm ref. MSTB 2,5/2-ST-5,08) must be used. JR01 : is the connector for the open collector output . A female connector with screw (Phoenix with 5 points pitch 5.08mm ref. MSTB 2,5/5-ST-5,08) must be used. JR02 : is the connector for the serial link (RS) . A female connector with screw (Phoenix with 5 points pitch 5.08mm ref. MSTB 2,5/5-ST-5,08) must be used. JR03 : is the connector for the outputs . A female connector with screw (Phoenix with 6 points pitch 3.81mm ref. MSTB 1,5/6-ST-3,81) must be used. JR04 : is the connector for the inputs . A female connector with screw (Phoenix with 4 points pitch 3.81mm ref. MSTB 1,5/4-ST-3,81) must be used. Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 10/27 7. INSTALLATION AND CONNECTION PROCEDURES FOR THE ASYNCHRONOUS LINKS 7.1. Cable to be used for serial link RS422 or RS485 1. In a "clean" electromagnetic environment - twisted pairs, without screen. 2. In a "noisy" electromagnetic environment - twisted pairs, individual screen for each pair The cables are electrically characterised by : - characteristic impédance (Z0 in ohms) - distributed capacity (CL in pF/m). - distributed resistance (RL in ohms/m) For short cable lengths, normal cables are satisfactory. For cable lengths greater than 1000 metres, high quality cables (low CL and RL) should be used for all baud rates. 7.2. Line termination For a simplex link, the termination (if present) should be placed at the receiving end of the line. For a duplex link, the termination (if present) should be placed at the each end of the line. For baud rates less than 1200 bauds, no termination is necessary. For baud rates greater than 9600 bauds and line lengths greater than 1000 metres, a resistor equal to the line impedance (120 ohms) is usually necessary. For cases in-between, there is no clear-cut rule and depends on individual installations (combination of baud-rate, line-length, cable quality, emitter/receiver characteristics). 7.3. Electrical connections For an RS-232 link , wiring up is straightforward, the TX and RX lines of both equipments are connected together. For a differential link (RS-422 or RS-485), the polarities are not always clearly defined. Normally the “+” line is at a high level at rest and is active low. For the “-” line, the opposite is true. This is the case for the differential interface for the HYPERX readers. However if the differential signals are generated by a converter acting on RS-232 signals, then the “+” line can be at a low level at rest and active high. In this case, the “+” line of one equipment must be connected to the “-” line of the other equipment. Connection of 0V Whether this is necessary or not, depends on the installation. If host and reader are distant with different local ground potentials, then an RS-232 link may not work if the 0V references are not connected. However connecting them will cause ground currents to circulate. In general, for large link lengths, a differential link should be used. This also tolerates a large common-mode voltage difference. 7.4. Networking 7.4.1. Topology The preferred topology is the bus. Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 11/27 Simplex wiring diagram: R : line-matching resistor, added if needed Half-duplex wiring diagram: R : line-matching resistors, added if needed The length of the derivation should be as short as possible (< 30 cm). The maximum length allowed can be calculated from the cable characteristics using the equation below. L < 1300 / (Z0 x CL) L in metres, ZO in ohms and CL in pF 7.4.2. Line biasing For RS-485, line biasing may prove necessary and must be done externally and only at one point on the line. The line “+” is connected to +5V via a 4K7 resistor. The line “-” is connected to 0V via a 4K7 resistor. Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 12/27 8. OPEN COLLECTOR INTERFACE Both the ISO2 and the WIEGAND interfaces use an Open-collector interface. For correct operation, pull-up resistors (typical values are 1K) must be connected to any voltage supply between 5V and 12V. For the ISO2 interface, this concerns the three signals STROBE, MDATA and PRES_BADGE, for the WIEGAND interface this concerns the two signals DATA1 and DATA0. The pins are associated with different signals, depending on the type of link used. The JR2 connector is used. pin ISO2 WIEGAND STROBE DATA “1” MDATA DATA “0” PRES_BADGE — Valim Valim GND GND Note : the Valim on pin 4 is internally connected to the supply voltage. Circuit diagram for open collector output stage inside the reader : VCC 33K uP Langue/ Language FR 10K CTP 12V 10n REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 13/27 For the ISO2 system : 5 - 12 VDC 1K HYPERX READER O1 CLOCK O2 DATA O3 PRES_BADGE USER EQUIPMENT O5 0V For Wiegand system : 5 - 12 VDC 1K O1 DATA1 O2 DATA0 HYPERX READER USER EQUIPMENT O5 0V Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 14/27 9. THE OUTPUTS (JR3) pin name VI1 SIC1 SIE1 VI2 SIC2 SIE2 description Supply voltage for output 1 Collector output 1 Emitter output 1 Supply voltage for output 2 Collector output 2 Emitter output 2 Détec te ur LMB Ve xt < 24Vdc Ve xt (or Valim pin 4 of JR02) 1 k oh ms Rext SIC 10 0 o hm s O p to c oup le u r S ortie 10ko h m s le d jaune SIE GND The external voltage must not exceed 24Vdc Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 15/27 10. THE INPUTS (JR4) pin name EI1 GND1 EI2 GND2 description Signal for input 1 Reference for input 1 Signal for input 2 Reference for input 1 EI must not exceed 24Vdc. EI < 24Vdc Détecteur LMB 10kohms 1kohms Opto coupleur JR04 Pin EI Nom EI 1 GND 1 EI 2 GND 2 Entrée 1 1 Entrée 2 1kohms led jaune GND Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 16/27 11. OPERATING FREQUENCY CHANNEL The enhanced compact reader LMB can operate using 119 different channels (31 for Europe). Each channel corresponds to a separate microwave frequency band. This is useful when several readers must be positioned close together. Using different channels on each reader eliminates mutual interference. 119 channels are available (31 for Europe), the frequency band is between 2435.25MHz and 2464.75MHz (2446.25MHz and 2453.75MHz for Europe) with a channel spacing of 250KHz. Checking the channel number : Push the red push-button "select" until the "nC" is displayed. Then push the black button once : the channel number appears. Numéro de canal 1 à 31 ☞ ☞ Display ☞ 31 Display Select After 2 or 3 seconds, the display switches off automatically. Modifying the channel number : Push the red button "select" until "nC" is displayed. Then push the black button "change" until the wanted channel number appears. When the channel number is right, push the red button "save" once to save the new channel number. Numéro de canal 1 à 31 ☞ FR ☞ Change 31 Select Langue/ Language ☞ Change ☞ Save ☞ Save REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 17/27 12. ADJUSTMENT OF THE READING RANGE All the readers are deliver with an adjustment with the maximum reading range. There are 4 positions for the adjustment : • Maximum reading range • Middle reading range • Minimum reading range • A few centimers. 12.1. Verification of the the position of the adjustment of the reading range : Push the red push-button "select" until the "Pr" is displayed. Then push the black button “display” once : the number corresponding to the reading range appears. qques cm ☞ ☞ ☞ ☞ Réglage Portée ☞ Display mini Select Display moyenne Display maxi Display The displays light off automatically after 2s. 12.2. Modification of the position of the reading range : Push the red push-button "select" until the "Pr" is displayed. Then push the black button “change” once : the number corresponding to the reading range appears. Push the black push-button "change" until the wanted position number appears. When the position number is right, push the red button "save" once to save the new position number. The new position number is memorised. ☞ Change mini Select Change moyenne Change ☞ ☞ ☞ ☞ qques cm ☞ ☞ ☞ ☞ Réglage Portée Save Save Save maxi Change Save The displays light off automatically after 2s. Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 18/27 13. ORIENTATION OF THE ANTENNA LMB_6012 LMB_7012 90°x 90° LMB_6013 LMB_7013 90°x 90° LMB_7023 90°x 45° LMB_6033 LMB_7033 45° x45° LMB_6034 45° x45° LMB_6035 45° x45° Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 19/27 1. FCC Notice This equipment has been tested and found to comply with the limits for a classB digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures : • Reorient or relocate the receiving antenna. • increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio or television technician for help. Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 20/27 14. CE Notice 0682 DECLARATION OF CONFORMITY BALOGH Toulouse 105 Avenue du Général Eisenhower 31023 TOULOUSE cedex 1 FRANCE This declaration that the following designated products LMB* comply with the essential protection requirements of R&TTE Directive 1999/5/CE on the approximation of the law of the Member States relating to Radio Spectrum Matters, EMC and Electrical safety. This declaration applies to all specimens manufactured with the attached technical documentation described in the annex II of the directive which form parts of the declaration. Assessment of compliance of the product with the requirements relating to the essential requirements acc. to Article 3 R&TTE was based on AnnexeV of the Directive 1999/5/CE and the following standards : Radio spectrum EMC Electrical safety Health : EN 300 440 : EN 401 489 : EN 60 950 : EN 50 371 * : LMB_6012/6013/6033/6034/6035/7012/7013/7023/7033 Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 21/27 Appendix 1 : General presentation HYP ER X ENHANCED COMPACT READER : LMB Red push-button Se lect/Sa ve Bla ck pus h-button Displa y/Change Bi-color led Bla ck push-button Rese t Low vo lta g e le d TTL link JR02 JK01 JT01 123 JR04 J R03 RS link JR01 1 2 3 4 51 2 3 4 5 12 34 1234 56 Inputs Outputs JK01 Buz z e r Display An a lo g m e a s ur em e n t JR01 : seria l link Pin Na me RS -2 32 RS -4 22 R S4 85 O1 TX + TX +V O2 TX -V -O3 RX + -3 -O4 RX -4 RX G ND G ND G ND G ND Pin Na me 1 I 2 G ND 3 Q JR02 : open colle ctor output JT01 Pin S u pp ly vol ta g e 12 Vdc t o 2 4Vd c C on ne c t or w ith 2 p oin t s Pi n Na me + Va lim 0V Nam e WI E G AN D IS O2 DATA “1” OC1 STRO BE OC2 MDATA DATA”0” -OC3 PRE S BADG E Vali m Va lim Vali m GND GN D G ND S up pl y c u rr e n t 1 A m a x / 12 Vdc . In pu t vo lt a g e Va l im b e t we e n 11Vd c m in a nd 28 Vd c m a x. T h e re d a n d blac k b utto n s are u s e d to c o n fig u re th e rea d e r Th e p ro c e dure t o d is play o r c h a n g e p a ram e te rs is : ☞ 1- s ele ct th e fu nct io n : re d pus h -b utto n Se le ct ☞ 2 - dis pla y/c h ang e th e p ara me te r : blac k p u s h-b u t to n Ch a n ge ☞ 3 - s av e th e p a ra met er : re d p u s h- butto n Sa v e Do c u m e n t re f. 6 0 0 0 X0 0 X0 1 Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 22/27 Appendix 2 : Serial link SERIAL LINK : RS-232 RS232 Hyper X JR01 Reader PC COM port subD9 JR01 RS232 RX TX HYPER X 3 READER PC RX TX 3 GND 5 GND SERIAL LINK : RS-422 RS-422 JR01 PC Hyper X Reader JR01 1 TX+ TX2 HYPER X RX+ READER 3 RX4 RS-422 RX+ RXTX+ TX- PC GND Document ref. 6000X00X01 Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 23/27 CONFIGUR ATION o f EN HANCED COMPAC T REA DER : LMB AS YNCHRONU S S ER IA L LINK : RS 2 3 2 / 4 2 2 / 4 8 5 Pl e as e s ee the c on fig uratio n manual to get a d e tail e d l is t of all p os s i ble c o nfi gu ration s ☞ 1- s e le ct th e fu n c ti o n : red pu s h -b u t to n OP E RAT IN G MO DE Se le ct R e d a n d b la c k p u s h -b u t to n s are us e d to c o n f ig u re th e re a d e r. Th e p ro c e d u re to d i s p l a y o r c h a n g e pa ram e te rs i s : ☞ 2 - d i s pla y/ c han g e the p ara m et e r : b lac k p us h -b utto n ☞ 3 - s a ve th e p ara m ete r : red pus h -bu tto n Ch ange Sa v e RS i n t e rfa c e R S 232 ☞ ☞ C ha n ge ☞ R S 422 S e le c t ☞ ☞ ☞ ☞ ☞ ☞ 31 B au d ra te 9 600 ☞ 4 800 S e le c t ☞ 1 200 19 200 ☞ Inte rrupt . ☞ P olling disa ble d 1st code Se le ct ☞ ☞ Ch a n ne l n u mb er 1 to 3 1 ☞ Sa v e ☞ 31 ☞ ☞ Re ade r ra ng e few cm ☞ 8/ none ☞ ☞ C ha n ge ☞ 7 / e ve n S e le c t ☞ 7 / odd s hort Se le ct ☞ m e dium Sa v e ☞ C ha n ge long Sa v e DE FAULT CONFIGURATION ☞ Sa v e ☞ ☞ S a ve ☞ ☞ S a ve ☞ ☞ S a ve ☞ Ch a n g e S a ve ☞ ☞ C h an g e Re s e t - Mes s a g e mo de : 0 - Bu z zer : O N - Dis t. c o d e filte r : dis ab le d - C ha nn e l nu mb e r : 9 - R ea de r ra n ge : 3 - Int e rfa ce : R S 2 32 - J -B US Ad re s s : 1 - Ba ud ra te : 1 9 2 00 ba ud s - P r otoc o l : P o llin g - Cha ra c t e r fo rm a t : 8 / no ne - F ra m e fo rm a t : J -B US Sa v e ☞ Ch a n g e ☞ S a ve ☞ Ch a n g e ☞ C ha n ge ☞ ☞ Sa v e S a ve ☞ Ch a n g e Ch a rac te r F o rma t S a ve ☞ Ch a n g e Sa v e Sa v e ☞ Ch a n g e S e le ct Sa v e ☞ Ch a n g e Sa v e S a ve ☞ Ch a n g e EEP ROM S a ve ☞ Ch a n g e ☞ ☞ C ha n ge S e le c t Dis tri b uto r c o de fi l te r Sa v e ☞ ☞ Ch a n g e ☞ C ha n ge ☞ ON S e le ct Sa v e C ha n ge P o l li n g / In te rru p t ☞ S a ve ☞ Ch a n g e Sa v e C ha n ge ☞ OF F ☞ C ha n ge ☞ B u zzer Sa v e ☞ ☞ Ch a n g e Sa v e ☞ ☞ Ch a n g e ☞ C ha n ge ☞ Se le ct Sa v e C ha n ge S e le c t ☞ ☞ C ha n ge ☞ Ch a n g e Sa v e C ha n ge J -B U S Ad re s s 1 to 3 1 Sa v e C ha n ge R S 485 Me s s a g e m o de - O ut p ut 1 : re a d in g 1 00 m s - O ut p ut 2 : re a d in g 2 s - Inp u t 1 : Dis a b le d - Inp u t 2 : Dis a b le d - Inte rfa c e TTL : n ot u s e d - Log : a ll (3 ) Doc ument re f. 6000X00X01 Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 24/27 Appendix 3 : Open collector output Connection to a WIEGAND system +5 to +12 Vdc JR02 1K 1K DATA1 DATA0 User Equipement HYPER X 3 READER GND Connection to an ISO2 system +5 to +12 Vdc JR02 HYPER X READER 1K 1K 1K STROBE MDATA PRES-BADGE User Equipement GND The use of the third wire (PRESBADGE) is optional Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 25/27 CONFIGURATION OF EN HANCED COMPAC T REA DER : LMB OP EN COLLEC TOR INTERFACE WIE GA ND AND IS O 2 Pl e as e s e e th e c o nfi gurati on manual to g e t a de taile d li s t o f al l po s s ib le con fig uratio ns ☞ 1- s ele c t the fu nctio n : re d p u s h -b u tto n O P E RATING MODE Se le ct Re d an d b l a c k p u s h -b u tto ns a re u s e d t o c o n f ig u re th e re a d e r. Th e pro c e d u re t o d is p l ay o r c ha ng e p a ram e te rs i s : ☞ 2 - d is pl a y /c han g e th e p ara m e te r : b l ac k p u s h -b u tto n ☞ 3- s a ve th e pa ram e te r : red p u s h -b utto n C ha nge S a ve Op en c o ll e c t o rs in t e rf ac e no t us e d ☞ ☞ C ha ng e ☞ IS O 2 fixe d ☞ IS O 2 Va r. ☞ ☞ ☞ ☞ ☞ ☞ S a ve ☞ Cha n g e Se le ct ☞ Sa ve ☞ S a ve ☞ Cha n g e ☞ C ha ng e ☞ Cha n g e Sa ve C ha ng e WIE GAND Sa ve C ha ng e S e le c t Me s s a g e m o de Bu z z e r Sa ve OFF ☞ S a ve ☞ Cha n g e MTB M Me an Ti m e B e tw e e n Me s s ag e s ☞ 0, 5 s ☞ C ha ng e ☞ 1s Sa ve ☞ 2s S e le c t C ha ng e ☞ 5s ☞ ☞ ☞ 0, 1 s ☞ 0, 5 s Sa ve ☞ 1s 2s ☞ ☞ 10 s ☞ ☞ ☞ S a ve ☞ ☞ S a ve ☞ ☞ Sa ve ☞ Cha n g e fe w c m ☞ Sa ve ☞ Cha n g e ☞ s hort m edium ☞ ☞ S a ve ☞ Cha n g e Se le ct Sa ve ☞ S a ve ☞ Cha n g e Sa ve lo ng ☞ ☞ S a ve ☞ Cha n g e S a ve Sa ve DEFAULT CONFIGURATION ☞ ☞ Ch a n g e Re se t - M es s a ge mod e : 0 - Buz z e r : ON - Di s t. c o de fil te r : d is a b l e d - C h an n e l n um b e r : 9 - R e ad e r ra ng e : 3m - In t e rfa c e : R S 23 2 - J -BUS Adr e s s : 1 - B a u d r a te : 19 20 0 b a u ds - P ro to c o l : P ol lin g - C h a r a c t e r form a t : 8 / n o ne - F r a m e form a t : J -B US 31 Re ad e r ra n g e Sa ve C ha ng e ☞ S a ve Cha n g e S e le ct ☞ C ha ng e ☞ Cha n g e ☞ C ha ng e 5s 1st c ode Ch a n ne l nu mb er 1 to 3 1 Sa ve C ha ng e ☞ ☞ Sa ve Cha n g e ☞ C ha ng e S e le c t ☞ Cha n g e EEPR OM Sa ve C ha ng e ☞ dis a ble d ☞ ☞ ☞ Cha n g e Se le ct Sa ve C ha ng e Ho ld ti m e ☞ Sa ve C ha ng e 10 s D is tribu to r c o de filte r Sa ve ☞ ON S e le ct ☞ C ha ng e ☞ ☞ Sa ve - O ut pu t 1 : re a d i ng 1 0 0m s - O ut pu t 2 : re a d i ng 2 s - In p ut 1 : Dis a b le d - In p ut 2 : Dis a b le d - In ter fa c e TT L : no t u s e d - Lo g : all (3) Doc umen t re f. 60 00X00X01 Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 26/27 Appendix 4 : Inputs / Outputs HYP ER X ENHANCED COMPACT READER : LMB Co nfig u ra tio n o f OUTP UTS : c o n n e c to r JR 0 3 JR03 P in O u tp u t 1 2 O u tp u t 2 5 N a me VI 1 S IC 1 S IE 1 VI 2 S IC 2 S IE 2 Ou tp u t 1 Not used ☞ Ch a ng e ☞ re a d. 100ms S e lec t LMB R e a d er VI hos t Ou put 2 S IC ☞ Sa ve ☞ ☞ Sa ve ☞ Ch a ng e Re x t 10 0 oh ms ☞ Ch a ng e Ve x t < 24 Vd c Ve x t (o r Va lim pin 4 o f J R02 ) 1 ko h m s ☞ Sa ve Ch a ng e rea ding. 2 s Op to co u p le u r ☞ Not used ☞ Sa ve ☞ Ch a ng e O u tp u t 1 0 koh m s ☞ re a d. 100ms ☞ Ch a ng e S e lec t Ye l l o w le d ☞ Sa ve rea ding. 2 s ☞ Sa ve ☞ Ch a ng e S IE GND hos t ☞ Sa ve ☞ Ch a ng e Sa ve Co nfig u ra tio n o f INPUTS : c o nn e c to r J R 0 4 JR04 In p u t 1 In p u t 2 P in Name EI 1 G ND 1 EI 2 G ND 2 In p ut 1 Disa ble d ☞ Re ading In p ut 2 1 koh m s Op to co u p le u r EI 1k o hms ☞ Sa ve ☞ Ch a ng e EI < 2 4Vd c LMB R e a d e r ☞ Ch a ng e S e lec t 1 0 ko h m s ☞ Disa ble d ☞ Sa ve ☞ Ch a ng e ☞ Re ading S e lec t Ye ll o w le d ☞ Sa ve ☞ Ch a ng e Sa ve G ND Docum e nt re f. 6000X00X01 Langue/ Language FR REFERENCE DU DOCUMENT / DOCUMENT REFERENCE Numéro / Number Code Doc. / Doc. Code Indice / Revision Index 13053 108 CE DOCUMENT EST LA PROPRIÉTÉ DE BALOGH IL NE PEUT ETRE COMMUNIQUÉ À DES TIERS SANS AUTORISATION ECRTITE PRÉALABLE. THIS DOCUMENT IS BALOGH PROPERTY.IT CANNOT BE DISCLOSED TO ANY PARTY WITHOUT PREVIOUS WRITTEN AUTHORIZATION. Pages 27/27
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Producer : Acrobat Distiller 4.05 for Windows Creator : Modify Date : 2002:10:03 17:45:43+02:00 Title : .Appendix 1 : General presentation . Create Date : 2002:10:03 17:44:59 Page Count : 27 Page Mode : UseNoneEXIF Metadata provided by EXIF.tools