BARCO AMM190WTD LCD Display User Manual AMM190WTD RevA1 111809 indd

Advan Int'l Corp. LCD Display AMM190WTD RevA1 111809 indd

User Manual

Download: BARCO AMM190WTD LCD Display User Manual AMM190WTD RevA1 111809 indd
Mirror Download [FCC.gov]BARCO AMM190WTD LCD Display User Manual AMM190WTD RevA1 111809 indd
Document ID1289760
Application IDrzukxJNhboCEF41XoV3SHg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize75.38kB (942272 bits)
Date Submitted2010-06-02 00:00:00
Date Available2010-06-02 00:00:00
Creation Date2009-11-18 18:31:02
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2009-12-11 15:02:15
Document TitleAMM190WTD RevA1 111809.indd
Document CreatorPScript5.dll Version 5.2
Document Author: ericlau

ADVAN
AUTO - SCANNING WITH DIGITAL CONTROL
LCD COLOR MEDICAL MONITOR
AMM190WTD
Operation Manual
For future reference, record the serial number of your display
monitor in the space below :
Serial Number
The serial number is located on the back of the monitor
AMM190WTD 1
ENGLISH
back of the monitor
WARNING
The title «WARNING» is used to inform the users of possible causes that could inflict the injury, death, or property
damage to the patients.
CAUTION
The title «CAUTION» is used to inform the users of possible causes that could inflict the patients although it might
not severe enough to cause deaths.
NOTE
The title «NOTE» is used to inform the users of items that
are of importance in terms of installation, operation, or
maintenance of the Equipment although the failure does
not inflict the bodily harm to the patients.
ADVAN INT’L CORP.2009
All other trademarks are the property of their reference owners.
This document is subject to change without notice.
Advan provides this information as reference only. Reference to other vendor’s
products does not imply any recommendation or endorsement.
Revision Control
Date
Description
REV.03 111809
Document number
2 User’s Guide
TABLE OF CONTENTS
Product Description and Intended Use ...................................................... 3
Warnings and Cautions ............................................................................. 4
Symbol Explanations ................................................................................. 7
EU Declaration of Conformity for Medical Applications ............................. 8
Safety Precaution ...................................................................................... 9
Cleaning Your Monitor ............................................................................... 9
Power Management Function.................................................................... 10
Preset Modes.............................................................................................. 11
Video Signals............................................................................................. 12
PIP / POP / PBP function........................................................................... 13
DDC ........................................................................................................... 14
Installation ................................................................................................. 14
Connecting the Power Cord ...................................................................... 15
User Function / Messages......................................................................... 16
OSD Section .............................................................................................. 17
Troubleshooting ......................................................................................... 25
Specification of (AMM190WTD) ................................................................ 26
Classification ............................................................................................. 27
Electromagnetic Compatibility ................................................................... 28
Dimension Drawing (mm) of AMM190WTD............................................... 31
Connectors ................................................................................................ 32
Description of Warranty ............................................................................. 33
Product Description and Intended Use
Please check the following items are present when you unpack the box, and save
the packing materials in case you will need to ship or transport the monitor in future.
• AMM190WTD LCD Monitor and two video cables (1) HD15 VGA cable*
(1) DVI-D cable*
•
AC Power cord**
•
AC-Adapter
•
Composite Video BNC Jack Cable and Super Video Cable
•
User Manual and 4pcs VESA screws
*Might be optional item, check with local representative
**Might vary pending on region stardard
CAUTION
Model No : JMW1100KA1800F01
ENGLISH
AMM190WTD 3
4
User’s Guide
Warnings and Cautions
Please read this manual and follow its instructions carefully. The words warning,
caution, and note carry special meanings and should be carefully reviewed:
Warning
The personal safety of the patient or physician may be
involved. Disregarding this information could result in
injury to the patient or physician.
Caution
Special service procedures or precautions must be
followed to avoid damaging the instrument.
Note
Special information to make maintenance easier or important
information more clear.
An exclamation mark within a triangle is intended to alert the
user to the presence of important operating and maintenance
instructions in the literature accompanying the product.
A lightning bolt within a triangle is intended to warn of the
presence of hazardous voltage. Refer all service to authorized
personnel.
Warning
TO AVOID POTENTIAL SERIOUS INJURY TO THE USER
AND THE PATIENT AND/OR DAMAGE TO THIS DEVICE,
THE USER MUST :
Warranty is void if any of these warnings are disregarded.
ADVAN Int’l Corp accepts full responsibility for the effects on safety, reliability, and
performance of the equipment only if:
• Re-adjustments, modifications, and/or repairs are carried out exclusively
by ADVAN Int’l Corp.
• The electrical installation of the relevant operating room complies with the
applicable IEC and CE requirements.
Warning
Federal law (United States of America) restricts this
device to use by, or on order of a physician.
The ADVAN Int’l Corp AMM190WTD monitor has been tested under UL 60601-1
standard and UL listed for Medical application.
ADVAN Int’l Corp reserves the right to make improvements in the product(s)
described herein. Product(s), therefore, may not agree in detail to the published
design or specifications. All specifications are subject to change without notice.
Please contact ADVAN Int’l Corp directly or phone your local ADVAN Int’l Corp sales
representative or agent for information on changes and new products.
1. Read the operating manual thoroughly and be familiar with its contents prior to using
this equipment.
2. Carefully unpack the unit and check if any damage occurred during shipment.
3. Should any solid object or liquid fall into the panel, unplug the unit and have it checked
by qualified personnel before operating it any further.
4. Uplug the unit if it is not to be used for an extended period of time. To disconnect the
cord, pull it out by the plug. Never pull the cord itself.
5. Be a qualified physician, having complete knowledge of the use of this equipment.
6. Test this equipment prior to a medical procedure. This monitor was fully tested at the
factory before shipment.
7. Avoid removing covers on control unit to avoid electric shock.
8. Attempt no internal repairs or adjustments not specifically detailed in this operating
manual.
9. Pay close attention to the care, cleaning instructions in this manual. A deviation may
cause damage (refer to the Cleaning section).
10. DO NOT STERILIZE MONITOR.
11. Read the entire instruction manual before assembling or connecting the camera.
12. Do not place the monitor or any other heavy object on the power cord. Damage to the
cable can cause fire or electirc shock.
13. Monitor with power supply is suitable for use in patient environment.
14. DO NOT stack more than 8 boxes high
This equipment has been tested and found to comply with the limits for medical devices in
IEC 601-1-2:2003. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to other devices, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving device.
- Increase the separation between the equipment.
- Connect the equipment into an outlet on a circuit different from that to which the other
device(s) are connected.
- Consult the manufacturer or field service technician for help.
NOTICES TO USER
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC WARNING
This equipement generates or uses radio frequency energy. Changes or modifications not
expressly approved by the party responsible for compliance could void the user’s authority
to operate the equipment. The user could lose the authority to operate this equipment if an
unauthorized change or modification is made.
ENGLISH
AMM190WTD 5
Warnings
6
User’s Guide
Cautions
1. The AC Adapter must be plugged into a Grounded power outlet.
2. Use only the proprietary AMM190WTD power supply for the
AMM190WTD monitor. Make a proper connection by ensuring that the
shrink tubing completely secures the connection between the DC power cord and the
extension cord.
3. Turn power off when unit is not in use.
4. Never operate the unit right after having transported from a cold location directly to a
warm location.
5. Do not expose the monitor to moisture or directly apply liquid cleaners directly to the
screen. Spray the cleaning solution into a soft cloth and clean gently.
6. Handle the monitor with care. Do not strike or scratch the screen.
7. Do not block the monitor cooling vents. The monitor is cooled by natural convection
and has no fan.
8. Do not force the monitor past 28 degrees of vertical when adjusting the screen
position. (For monitors equipped with stands only.)
9. Remove the power module and connection when transporting the unit.
10. Save the original carton and associated packing material. They will be useful should
you have to transport or ship the unit.
11. Allow adequate air circulation to prevent internal heat buildup.
12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains,
draperies) that may block the ventilation slots.
13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock.
14. The unit is designed for operation in a horizontal position. Never operate the unit in
a vertical position.
15. Keep the unit away from equipment with strong magnets (i.e. a large loudspeaker.)
16. Do not expose the monitor to moisture or excessive dust.
17. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/or
IEC 60601-1-1 harmonized national standard or the combination should be evaluated.
Do not touch the patient with signal input or output connectors.
18. Use only a hospital grade power supply cord.
19. This equipment has been tested and found to comply with the limit for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable generate uses and can radiate radio frequency energy, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in
a particular installation, which can be detemined by turing the equipment off and on,
the user is encourage to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving device.
• Increase the separation distance between the equipment.
• Connect the equipment to an outlet on a circuit different from that to which the
other device(s) are connected.
• Consult the manufacturer or field service technican for help.
20. Grounding reliability can only be achieved when the equipment is connected to an
equipment receptacle labeled “Hospital Only” or “Hospital Grade.”
Note
To connect to an international power supply, use a an attachment plug
appropriate for the power outlet.
Note
Refer to the “Electromagnetic Compatibility” (EMC) section of this manual to
ensure EMC. The AMM190WTD must be installed and operated
according to the EMC information provided in this manual.
Dangerous: High Voltage
Direct Current
Serial Number
Top – Bottom
Fragile
Do not get wet
Consult accompanying documents.
Indicates proof of conformity to applicable European Economic
Community Council directives and to harmonized standards
published in the official journal of the European Communities.
Authorized Representative in Europe
Indicates protective earth ground.
For indoor use only.
Medical Equipment is in accordance with UL 60601-1 and CAN/
CSA C22.2 No. 601.1 in regards to electric shock, fire hazards,
51LJ
Medical Equipment and mechanical hazards.
E215822
Tested to comply with FCC Class B standards.
DC power control switch
ENGLISH
AMM190WTD 7
Symbol Definitions
8
User’s Guide
EU Declaration of Conformity for Medical Applications
A Declaration of Conformity has been filed for this product. A sample
of this document may be found in the addendum which accompanied
this manual. For a copy of the Declaration of Conformity document,
please contact ADVAN Int’l Corp. and request for AMM190WTD DOC.
Prepare for Unpack
Before you unpack your monitor, prepare a suitable workspace. You
need a stable and level surface near a grounded wall outlet in an area
which is relatively free of glare from sunlight or other sources of bright
light. The monitor is cooled by natural convection (it has no fan).
For optimum performance, do not block the cooling vents.
While unpacking the monitor, inspect it and other package contents
for shipping damage that could cause a fire or shock hazard. Immediately report any shipping damage to the carrier or transportation
company and contact customer service for monitor in the future or in
case of return.
After you unpack the monitor, make sure the following items are included
• Monitor with video cable
• AC adapter with cable
CAUTION: AC Adapter must be plugged into Grounded a power outlet
CAUTION : AC adapter
Model No: JMW1100KA1800F01
• This operations manual
Note: Your system provider may offer alternative cords or cables
depending on the installation requirement and local geography issues.
AMM190WTD 9
·
Avoid placing the monitor, or any other heavy object, on the power cord
to prevent fire or electrical shock from damage to the power cord.
·
Do not expose the monitor to rain, excessive moisture, or dust to avoid
fire or shock hazard.
·
Do not cover the slots or openings of the monitor for proper heat
dissipation. Always put the monitor in a place where there is adequate
ventilation.
·
Avoid placing the monitor against a bright background or where sunlight
or other light sources may reflect on the area of the monitor. Place the monitor
just below eye level.
·
Handle with care when transporting the monitor.
·
Refrain from giving the shock or scratch to the screen, as screen is
fragile.
CLEANING YOUR MONITOR
No specific liquid or chemical necessary when cleaning this LCD monitor
However, we suggest to clean the monitor with non-abrasive cloths and cleaning
solutions used in hospitals to clean similar equipment. We recommend using 70%
Isopropyl alcohol for the screen surface and warm water and a mild detergent for all
other surfaces. Other acceptable cleaning agents are listed below:
• 70% isopropyl alcohol
• Cidex (2.4% glutaraldehyde solution)
• 0.5% Chlorhexidine in 70% isopropyl alcohol
To clean the screen, do not spray liquid cleaners directly on to the unit. Stand away
Form the monitor and spray cleaning solution onto a cloth. Without applying excessive pressure, clean the screen with the slightly dampened rag.
Recomendation to Use more than One Unit
As unforeseen situation can occationally occur for the monitor, when the display
is used for safety control of human, equipments or unstable picture, or for
emagencies, we strongly recommend you use more than one unit or prepare a
spare unit.
ENGLISH
SAFETY PRECAUTION
10
User’s Guide
POWER MANAGEMENT FUNCTION
The monitor is equipped with the power management function which automatically
reduce the power consumption when not in use in three power level modes.
•
Stand-by Mode
The monitor goes into stand-by mode when the horizontal sync signal is off for
about 10 seconds. In this mode, the screen goes off and the power LED blinks
for 1 seconds On and 1 second Off. The screen is displayed after the horizontal
sync signal is restored.
•
Suspend Mode
The monitor goes into suspend mode when the vertical sync signal is off for
about 10 seconds. The power consumption during this is W. In this mode, the
screen goes off and the power LED blinks for 1 seconds On and 1 second Off.
The screen is displayed after the vertical sync signal is restored.
•
Off Mode
The monitor goes into power-off mode when the vertical and horizontal sync
signals are off for about 10 seconds. In this mode, the screen goes off and the
power LED blinks for 1 seconds On and 1 second Off. The screen is displayed
after the vertical and horizontal sync signals are restored.
Power Management System
The AMM190WTD Medical Monitor power management proposal. Provides four
phases of power-saving modes by detecting the horizontal sync signal as shown in
the table below.
State
Normal
Operation
DPMS
Standby
DPMS
Suspend
DPMS Off
Horizontal Sync
Active
Inactive
Active
Inactive
Vertical Sync
Active
Active
Inactive
Inactive
Video
Active
Blanked
Blanked
Blanked
Power Indicator
Green
Green Flashing (1
sec. Interval)
Green Flashing (1
sec. Interval)
Green Flashing (1
sec. Interval)
Power
Consumption
75W
27W
27W
27W
When the monitor is power saving mode or detects an incorrect timing, the screen
will be blank and power LED indicator will blink.
AMM190WTD 11
ENGLISH
PRESET MODES
DVI and VGA input signal formats
Resolution
Horizontal
frequency
( KHz )
Vertical
frequency
( Hz )
Pixel clock
( MHz )
640 x 350 @70Hz
31.469
70.087
25.175
640 x 480 @60Hz
31.469
59.940
25.175
640 x 480 @75Hz
37.500
75.000
31.500
640 x 480 @85Hz
43.269
85.008
36.000
800 x 600 @56Hz
35.156
56.250
36.000
800 x 600 @60Hz
37.879
60.317
40.000
800 x 600 @72Hz
48.077
72.188
50.000
800 x 600 @75Hz
46.875
75.000
49.500
800 x 600 @85Hz
53.674
85.061
56.250
1024 x 768 @60Hz
48.363
60.004
65.000
1024 x 768 @70Hz
56.476
70.069
75.000
1024 x 768 @75Hz
60.023
75.029
78.750
1024 x 768 @85Hz
68.677
84.997
94.500
1152 x 864 @60Hz
54.348
60.053
80.000
1152 x 864 @70Hz
63.955
70.016
94.200
1152 x 864 @75Hz
67.500
75.000
108.000
1280 x 960 @60Hz
60.000
60.000
108.000
1280 x 1024 @60Hz
63.974
60.013
108.500
1280 x 1024 @75Hz
79.976
75.025
135.000
1680 x 1050 @59.946Hz
64.742
59.946
119.125
1680 x 1050 @59.944Hz
65.160
59.944
147.000
1600 x 1200 @60Hz
74.077
59.981
130.375
12
User’s Guide
Video Signals
Component
Format
DVI
VGA
/SOG
Video
Y/C
NTSC -M
NTSC-443
PAL-BDGHI
PAL-M
PAL-N
PAL-60
480/59.94i
SDI
1/2
480/59.94p
576/50i
Y/Pb
/Pr
RGB
+CS
RGB
+HV
576/50p
720/50p
720/59.94p
720/60p
1035/59.94i
1035/60i
1080/23.98psf
1080/24psf
1080/23.98p
1080/24p
1080/25p
1080/29.97p
1080/30p
1080/50i
1080/59.94i
1080/60i
1080/50p
O*1
1080/60p
O*1
*1 Available for VGA.
AMM190WTD 13
ENGLISH
PIP / POP / PBP function
The following combination options are available to you:
VGA
DVI
SDI1
SDI2
C-Video
Y-C
Component
/ RGBs
VGA
DVI
SDI1
SDI2
C-Video
Y-C
Component /
RGBs
Main
SOG
PIP
SOG
14
User’s Guide
DDC
To make your installation easier, the monitor is able to Plug and Play with your
system if your system also supports DDC protocol. The DDC (Display Data
Channel) is a communication protocol through which the monitor automatically
informs the host system about its capabilities, for example, supported resolutions
and corresponding timing. The monitor supports DDC1 and DDC2B standard.
INSTALLATION
To install the monitor to your host system, please follow the steps as given below:
Steps
1. Use the supplied video cable (DVI, VGA, S-Video, C-Video) then connect to the
host system accordingly.
2. Connect the DC power to the DC power connector on the monitor.
3. Connect one end of AC power cord into the AC Adapter and the other end to AC
power outlet.
4. Then turn the host system on and then the monitor.
5. If the monitor still does not function properly, please refer to the troubleshooting
section to diagnose the problem.
S - Video
DVI
VGA
SDI IN
IN
OUT
DC Power
C - Video /
SOG
RGB / Component
SDI OUT
AMM190WTD 15
ENGLISH
CONNECTING the POWER CORD
* Check first to make sure that the power cord you use is the correct type required
for your area.
* This monitor has an universal AC adapter that allows operation in either
AC 100 - 240 V ac voltage area. No user-adjustment is required.
* Plug one end of the power cord to the AC adapter, plug another end to a proper
AC outlet.
The cord set should have the appropriate safety approvals for the country in which
the equipment will be installed and marked HAR.
For 120 volt Applications, use only UL Listed deachable power cord with NEMA
configuration 5-15P type (parallel blades) plug cap. For 240 volt applications use
only UL Listed Detachable power supply cord with NEMA configuration 6-15P type
(tandem blades) plug cap.
Hospital-grade
power cord
Extension power cord (optional)
Model No: 1501047004 (5ft) or
1501047005 (15ft) or
1501047006 (75ft)
Power Supply
Model No: JMW1100KA1800F01
AMM190WTD
16
User’s Guide
User Functions / Messages
Key Name and Function
Power LED : Lights up to indicate the power is turned ON.
Power Switch : To power ON or OFF the monitor.
Rotary switch : With the OSD menu activated, increases the value of the selected
(Ture Right)
parameter or moves rightward in OSD menu.
Rotary switch : With the OSD menu activated, increases the value of the selected
(Ture Left)
parameter or moves leftward in OSD menu.
PIP Switch : To enable or disable Picture In Picture function.
PBP Switch : To enable or disable Picture By Picture function.
POP Switch : To enable or disable Picture On Picture function.
Adjust Switch : To activate or deactivate image adjustment in sub screen of PIP,
PBP, POP mode.
Locker Switch : To turn ON or OFF the system.
How to access the menu
1. Push the “Knob” button to activate the OSD menu.
2. Able to turn left or right the button to select those icons. The icon will be
highlighted when is selected.
3. Push the “knob” button to go into the another OSD menu.
4. Turn left or right “Knob” button to increase or decrease the number of selected
function.
5. In order to exit from the OSD menu in a different layer, then choose the “Exit
option”. In case of long pushing and holding the button around two or three
seconds, then it will completely out from the menu regardless wherever you are.
6. Turn the “Knob” button in a fast way to the left or right, while the menu is not
activated, then input signal menu will turns up with “V” mark which is chosen
current available input signal. You can switch to another input signal source by
turning the knob slowly then select the target source by pushing the knob.
AMM190WTD 17
ENGLISH
OSD Section
Main Menu
Chromatic
Adjust Color Temp, Gamma
Visual
Adjust Brightness, Contrast, Phase, Chroma,
Sharpness-H, Sharpness-V
Setting
Adjust Scale Mode, Color Space, Mirror, Freeze Frame,
Zoom / Pan, PIP, POP, PBP
Advanced
Adjust OSD Position Control, Screen Control, DPMS, Auto
Source Select, Smart Select, Restore Factory, Key Lock
Information
Adjust Custom Entry, SN, Run Time, Input Format
Exit
Exit the menu
18
User’s Guide
OSD Section
Chromatic
Color Temp
Change the color temperature - D65, D93, S1, S2
Gamma
Change the gamma value - 1.8, 1.9, 1.95, 2.1, 2.1S, 2.2, 2.3,
2.4, 2.4S, S0, Radio graph
Exit
Exit the menu
Visual
Brightness
Adjust the brightness of panel (Range 0 - 100)
Contrast
Adjust the contrast of video (Range 0 - 100)
Phase
Adjust the phase of video (Range 0 - 100)
*available for C and S - video
Chroma
Adjust the chroma of video (Range 0 - 100)
*available for C and S - video
Sharpness-H
Set the sharpness of horizontal image (Range 0 - 100)
Sharpness-V
Set the sharpness of vertical image (Range 0 - 100)
Exit
Exit the menu
AMM190WTD 19
ENGLISH
OSD Section
Setting
Scale Mode
Change the scale mode - Fill all, One to One,
Vertical - fill, Horizontal - fill, Fill aspect ratio
Color Space
Change color space between RGB and YPbPr
*available for Component and RGBS
Mirror
Off / On mirror image
Freeze Frame
Off / On freeze frame
Zoom / Pan
Enable zoom - in and pan function
PIP
Enable PIP (Picture In Picture) function
POP
Enable POP (Picture On Picture) function
PBP
Enable PBP (Picture By Picture) function
Exit
Exit the menu
20
User’s Guide
OSD Section
Sub menu of PIP
Mode
PIP Mode ON / Off
Source
PIP sub screen source - SDI1,2, C-Video, S-Video,
Component, VGA, DVI, SOG
Position
PIP sub screen position - Top L, Top R, Bottom L, Bottom R
Size
PIP sub screen size - Small, Medium, Large
Blending
PIP sub screen blending (Range 0 - 100)
Swap
PIP sub screen swap
Exit
Exit the menu
Sub menu of PBP
Mode
PBP Mode ON / Off
Source
PBP sub screen source - SDI1,2, C-Video, S-Video,
Component, VGA, DVI, SOG
Swap
PBP sub screen swap
Exit
Exit the menu
AMM190WTD 21
ENGLISH
OSD Section
Sub menu of POP
Mode
POP Mode ON / Off
Source
POP sub screen source - SDI1,2, C-Video, S-Video,
Component, VGA, DVI, SOG
Position
POP sub screen position - Top L, Top R, Bottom L, Bottom R
Size
POP sub screen size - Small, Medium, Large, Full
Blending
POP sub screen blending (Range 0 - 100)
Swap
POP sub screen swap
Exit
Exit the menu
22
User’s Guide
OSD Section
Advanced
OSD Position
Change the OSD menu - Position, Background,
Control
OSD time out, Language
Screen Control
Control and adjust H and V position, Freqency, Phase
Noise Reduction, Motion Offset
DPMS
Change the DPMS
Auto Source
Adjust Auto Source Select between on and off
Select
Smart Select
Enable / Disable smart select sub menu
Restore Factory Changes the all OSD value to factory outgoing status
Key Lock
Set to key lock mode
Exit
Exit the menu
AMM190WTD 23
Sub menu of OSD Control
H-position
Adjust OSD H - position (Range 0 - 100)
V-position
Adjust OSD V - position (Range 0 - 100)
Back ground
Adjust transparency of OSD back ground (Range 0 - 100)
OSD Time out
Adjust OSD time out - 5s, 10s, 15s, 20s, 1m, 2m
Language
OSD language - English, Japanese, Chinese, Korean,
French, German
Exit
Exit the menu
Sub menu of Screen Control
H-position
Adjust screen H - position (Range 0 - 100)
*available for VGA
V-position
Adjust screen V - position (Range 0 - 100)
*available for VGA
Frequency
Adjust frequency (Range 0 - 100)
*available for VGA
Phase
Adjust phase (Range 0 - 100)
*available for VGA
Noise
Noise reduction (Range 0 - 100)
Reduction
*available for Component, C-Video and S-Video
Motion Offset
Motion offset (Range 0 - 15)
*available for Component, C-Video and S-Video
Exit
Exit the menu
ENGLISH
OSD Section
24
User’s Guide
OSD Section
Information
Custom Entry
Change the user or monitor’s name
SN
Display the serial number
Run Time
Display the total run time
Input Format
Display the current input resolution and vertical frequency
Exit
Exit the menu
AMM190WTD 25
Before sending your LCD monitor for servicing, please check the troubleshooting
list below to see if you can self-diagnose the problem.
Problems
Current Status
Remedy
No Picture
LED ON
· Using OSD, adjust brightness and
contrast to maximum or reset to their
default settings.
LED OFF
· Check the Locker switch and Power
switch.
· Check if AC power cord is properly
connected to the AC adapter.
LED Blinking
· Check if video signal cable is properly
connected at the back of monitor.
· Check if the power to computer system
is ON.
Abnormal Picture
Unstable Picture
· Check if the specification of graphics
adapter and monitor is in compliance
which may be causing the input signal
frequency mismatch.
Display is missing, center shift,
or too small or too large in
display size
· Using Auto Setup button, if still display
abnormal picture then adjust CLOCK,
CLOCK-PHASE, H-POSITION and VPOSITION with non-standard signals.
· Using OSD, in case of missing full-screen
image, please select other resolution in
your Operating System (Windows 95/98,
NT) or other vertical refresh timing.
· Must wait for a few seconds after
adjusting the size of the image before
changing or disconnecting the signal or
powering OFF the monitor.
ENGLISH
TROUBLESHOOTING
26
User’s Guide
SPECIFICATION
Model
LCD Panel
Type
Resolution
Pixel Pitch
Display Color
Color Tone
Response Time
Face Finishing
Viewing Angle
Input Signal (Analog &
Sync (Analog)
Composite Sync (Analog)
Y/C Sync (Analog)
AMM190WTD
19 TFT LCD Panel
Active Matrix
1680 x 1050 @ 60Hz
0.24mm
16.7M colors
Up to 256 color tone
<25ms Typ.
Protective Filter with Anti-Reflected Hard Coated
+/- 85°(Horizontal), +/- 85° (vertical)
Digital)
2.5~5.0Vp-p separated sync
Composite Video (NTSC/PAL)
S-Video (NTSC/PAL)
- 75 Ohm
Input Impedance (Analog) Video
Sync - 1k Ohm
Digital
24-bit MSB RGB TMDS Dual Link
Scanning Frequency
Horizontal
31.47~79.98kHz
Vertical
50~85Hz
Display Size
HxV
16.1 x 10.1 (409.5mm x 255.94mm)
Brightness, Contrast Radtio, Gray Scales
Brightness
230 cd/m2 (Typ.)
Contrast Ratio
700:1 (Typ.)
Signal Input Connector
Video
DVI, HD15, SD/HD-SDI 1 and 2 , Component Y/G, Pb/B, Pr/R, H/CS, VS, C-Video and
S-Video
Communication
DB9 (RS232)
Signal Output Connector (Loop Through)
Video
SD/HD-SDI, Component Y/G, Pb/B, Pr/R, H/CS, VS, C-Video and S-Video
Operating/Storage Environment
Operating Temperature
32° ~ 95°F (0° - 35°C)
Storage Temperature
-4° ~ 140°F (-20° - 60°C)
Storage Humidity
10 ~ 85%RH (without condensation)
VESA Mounting
100mm x 100mm
Power Source
Display Monitor
AC-Adapter
DC 18V 6.67A
AC100~240V 50/60Hz, 1.4~0.6A
Regulations
Safety, EMI & Environmental
UL 60601-1, EN60601-1, EN60601-1-2, FCC, CE, CCC, VCCI, ROHS, IP:X1 Compliance
Dimension
Free Mount
19.5(W) x 12.87(H) x 3.39(D) 495.4mm(W) x 326.9mm(H) x 86mm(D)
Weight
Free Mount
Optional Module
Base Stand
Adjustable high, swivel and tilt base stand
** All contents are subject to change without notice.
ENGLISH
AMM190WTD 27
: Direct Current
51LJ
Medical Equipment
E215822
MEDICAL EQUIPMENT
WITH RESPECT TO ELECTRIC SHOCK,
FIRE AND MECHANICAL HAZARDS ONLY
IN ACCORDANCE WITH UL 60601-1, AND
CAN/CSA C22.2 NO. 601.1
: UL approval mark according to the
safety standard for Medical equipment
This monitor is intended for use in Health Care Facilities model AMM190WTD
Equipment is not suitable for use in the presence of flammable anesthetic mixture
with air or with oxygen or nitrous oxide.
No user serviceable parts inside, ask qualified personnel when accessing inside.
For disposal of waste product, follow the requirement of local code.
Electrical input rating:
Classification
Type of protection against electric shock: Class I Equipment.
Degree of protection against the ingress of water: IPX1 compliance.
Mode of operation: Continuous
This monitor has been tested to comply with IEC/EN 60601-1, IEC/EN60601-1-2
and is certified by UL to medical standard UL60601-1(UL/cUL Mark).
Because many medical offices are located in residential areas, this monitor, in addition to the medical requirements, has also been tested and found to comply with
the limits for FCC Class B computing devices in a typically configured system. It is
the system integrator or configurer’s responsibility to test and ensure that the entire
system complies with applicable EMC laws.
Environmental conditions for transport and storage:
Temperature range within -4° to 140° F (-20° to 60°C)
Relative humidity range within 10% to 85%
Atmospheric pressure range within 500 to 1060 hPa.
28
User’s Guide
Electromagnetic Compatibility
Like other electrical medical equipment, the AMM190WTD requires special precautions
to ensure electromagnetic compatibility with other electrical medical devices. To ensure
electromagnetic compatibility (EMC), the AMM190WTD must be installed and operated
according to the EMC information provided in this manual.
Note
The AMM190WTD has been designed and tested to comply with IEC 606011-2:2001 requirements for EMC with other devices.
Caution Portable and mobile RF communications equipment may affect
the normal function of the AMM190WTD.
Warning Do not use cables or accessories other than those provided
with the AMM190WTD, as this may result in increased electromagnetic emissions or decreased immunity to such emissions.
Warning If the AMM190WTD is used adjacent to or stacked with other
equipment, observe and verify normal operation of the AMM190WTD in the
configuration in which it will be used prior to using it in a surgical procedure.
Consult the tables below for guidance in placing the AMM190WTD.
Manufacturer’s declaration - electromagnetic emission
The Model AMM190WTD is intended for use in the electromagnetic environment specified below.
The customer or the user of AMM190WTD should assure that it is used in such an environment.
Emission test
Compliance
RF emissions CISPR 11
Group 1
RF emissions CISPR 11
Class B
Harmonic emissions
IEC61000-3-2
Class D
Voltage Fluctuations
IEC61000-3-3
Complies
Electromagnetic environment - guidance
The Model AMM190WTD uses RF energy only for its internal
function. Therefore, its RF emissions are very low and are not
likely to cause any interference in nearby electronic equipment
AMM190WTD is suitable for use in all establishments, including
domestic establishments and those directly connected to the
public low-voltage power supply network that supplies buildings
used for domestic purposes
Manufacturer’s declaration - electromagnetic immunity
The Model AMM190WTD is intended for use in the electromagnetic environment specified below.
The customer or the user of AMM190WTD should assure that it is used in such an environment.
Immunity Test
IEC 60601 Test Level
Compliance Level
Electromagnetic
environment - guidance
Electrostatic discharge
(ESD)
IEC61000-4-2
6 kV contact
8 kV air
6 kV contact
8 kV air
Floors should be wood,
concrete or ceramic tile.
If floors are covered with
synthetic material, the relative
humidity should be at least
30%.
Electrical fast transient
/burst IEC61000-4-4
2 kV for power supply lines
1 kV for input / output lines
2 kV for power supply lines
1 kV for input / output lines
Mains power quality
should be that of a typical
commercial or hospital
environment.
Surge
IEC61000-4-5
1 kV differential mode
2 kV common mode
1 kV differential mode
2 kV common mode
Mains power quality
should be that of a typical
commercial or hospital
environment.
Power frequency
(50/60Hz) magnetic field
IEC 61000-4-8
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines IEC61000-4-11
3.0 A/m
Power frequency magnetic fields should be
at levels characteristic
of a typical location in
a typical commercial or
hospital environment.
3.0 A/m
<5% Ut (>95% dip in Ut)
for 0.5 cycle
<5% Ut (>95% dip in Ut)
for 0.5 cycle
40% Ut (60% dip in Ut)
for 5 cycles
40% Ut (60% dip in Ut)
for 5 cycles
70% Ut (30% dip in Ut)
for 25 cycles
70% Ut (30% dip in Ut)
for 25 cycles
<5% Ut (>95% dip in Ut)
for 5 sec.
<5% Ut (>95% dip in Ut)
for 5 sec.
Mains power quaility
should be that of a typical
commercial or hospital
environment. If the
user of the AMM213TD/
AMM240WTD image
intensifier requires continued operation during
power mains interruptions, it is recommended
that the AMM213TD/
AMM240WTD image intensifier be powered from
an uninterruptible power
supply or a battery.
Note: Ut is the A.C. mains voltage prior to application of the test level.
Manufacturer’s declaration - electromagnetic immunity
The Model AMM190WTD is intended for use in the electromagnetic environment specified below.
The customer or the user of AMM190WTD should ensure that it is used in such an environment.
Immunity Test
IEC 60601 Test
Level
Compliance Level
Electromagnetic environment
- guidance
Portable and mobile RF communications
equipment should be used no closer to any
part of the AMM213TD/ AMM240WTD,
including cables, than the recommended
separation distance calculated from the
equation applicable to the frequency of the
transmitter.
Recommended Separation Distance
0.15 MHz to 80 MHz
Conducted RF
IEC61000-4-6
3 Vrms
150 KHz to 80 MHz
3 Vrms
150 KHz to 80 MHz
Radiated RF
IEC 61000-4-3
3 V/m
80MHz to 2.5 GHz
3 V/m
80MHz to 2.5 GHz
80 MHz to 800 MHz
800 MHz to 2.5 GHz
where P is the maximum oputput power
rating of the transmitter in watts (W)
according to the transmitter manufacturer
and d is the recommended separation
distance in meters (m).
Field strengths from fixed RF transmitters,
as deter-mined by an electromagnetic
site survey (a), should be less than the
compliance level in each frequency range
(b).Interferency may occur in the vicinity
of equipment marked with the follwing
symbol:
NOTE 1: At 80MHz and 800MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects, and people.
(a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast, connot be predicted theoretically with accuracy.
To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength in the location in which the AMM190WTD is used exceeds the applicable RF
compliance level above, the AMM190WTD should be observed to verify normal operation. If abnormal performance is
observed, additional measures may be necessary, such as reorienting or relocating the AMM190WTD.
(b) Over the frequency range 150kHz to 80MHz, field strengths should be less than [V1] V/m.
ENGLISH
AMM190WTD 29
30
User’s Guide
Recommended Separation Distances Between Portable and Mobile RF Communications Equipement and the AMM190WTD System
The AMM190WTD system is intended for use in an electromagnetic environment in which radiated RF
disturbances are controlled. The user of the AMM190WTD system can help prevent electromagnetic
interference by maintaining a minimum distance between portable and mobile RF communications
equipment (transmitters) and the AMM190WTD system as recommended below, according to the maximum
output power of the communications equipment.
Separation distance (m) according to frequency of transmitter
Rated maximum output
power (W) of transmitter
150kHz to 80MHz
d=1.17, p
80MHz to 800MHz
d=1.17, p
800MHz to 2.5GHz
d=2.33, p
0.01
0.12
0.12
0.23
0.1
0.37
0.37
0.74
1.17
1.17
2.33
10
3.70
3.70
7.37
100
11.70
11.70
23.30
For transmitters rated at a maximum output power not listed above, the recommended separation distance (d) in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum
output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects, and people.
AMM190WTD 31
ENGLISH
Dimension Drawing (mm) of AMM190WTD
REAR VIEW
32
User’s Guide
Connectors
DC Input
Connector Jack Power Input
Pin
Description
Pin
Description
GND
NC
GND
VCC_24V
VCC_24V
Video Input
24 pin DVI-I connector.
DDWG or equivalent connector.
Pin
Description
Pin
Description
Pin
Description
T.M.D.S. Data2-
11
T.M.D.S. Data1 Shield
21
NC
T.M.D.S. Data2+
12
NC
22
T.M.D.S. Clock Shield
T.M.D.S. Data2 Shield
13
NC
23
T.M.D.S. Clock+
NC
14
+5V Power
24
T.M.D.S. Clock-
NC
15
Ground (for +5V)
25
Analog Red
DDC Clock
16
Hot Plug Detect
26
Analog Green
DDC Data
17
T.M.D.S. Data0-
27
Analog Blue
Analog V - Sync
18
T.M.D.S. Data0+
28
Analog H - Sync
29
GND(for analog signal)
T.M.D.S. Data1-
19
T.M.D.S. Data0 Shield
10
T.M.D.S. Data1+
20
NC
15 pin VGA connector.
Pin
Description
Pin
Description
Pin
Description
GRED
GND
11
NC
GGREEN
GND
12
GSDA
GBLUE
GND
13
IHS
GND
G5V
14
IVS
GND
10
GND
15
GSCL
S - Video connector.
Pin
Description
Pin
Description
GND
CHROMA
GND
LUMA
C - Video connector.
Pin
Description
DATA IN / OUT
Description of Warranty
Advan warrants that the goods sold hereunder will be free of defects in materials
and workmanship, and such goods will substantially conform to the specifications
furnished by Advan, and to any drawings or specifications furnished to Advan by the
Buyer if approved by Advan. This warranty shall be effective only if Advan receives
notice of such defect or nonconformance during the period of the warranty. In the
event of warranty claim with EOL (End of Life) product(s), Advan has the exclusive
right to replace with refurbished units or with an equivalent product.
Commencement and Duration of Warranty
The warranty period begins on the date of shipment from Advan. The goods sold
hereunder are warranted for a period of 18 months from date of shipment unless
otherwise agreed to by Buyer and Advan. No extension of the warranty will be given
during the time the goods are in Advan possession.
Place of Repair or Replacement
In order to obtain service under this warranty, Buyer must notify Advan of the defect
before expiration on the warranty period, and request a “Return Material Authorization Number.” If the configuration has been modified in any manner, the product
must be returned to its original configuration before any warranty service will be
perfomed by Advan. No goods are to be returned to Advan without prior authorization. Buyer will be responsible for packaging and shipping the defective goods to
the Advan Service Facility with shipping charges prepaid.
Limitation of Warranty
Monitor:
For 18 months after the date of purchase, ADVAN or its Authorized Service Centers,
will repair or replace if defective in material or workmanship. This Limited Warranty
does not include cleaning, or damage caused by accident, neglect, misuse or
improper installation or operation, any damage caused from service, maintenance,
modifications or tampering by anyone other than an ADVAN Authorized Service
Representative, or by the use of supplies, consumable items and conditions beyond
the control of ADVAN, such as common carrier provided equipment and/or facilities,
operation of ADVAN product in excess of the specifications or with the Serial
Number or Rating label removed.
ENGLISH
AMM190WTD 33
34 User’s Guide
ADVAN DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED
INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE, EXCEPT TO
THE EXTENT THAT ANY WARRANTIES IMPLIED BY LAW CANNOT BE VALIDLY
WAIVED.
No oral or written information or advice given by ADVAN, its authorized service
center, distributors, dealers, agents or employees, shall create another warranty or
modify this warranty. This warranty states ADVAN’s entire liability and your exclusive
remedy against ADVAN for any failure of the ADVAN’s product to operate properly.
Neither ADVAN nor anyone else involved in the development, production, or delivery
of this product shall be liable for any indirect, incidental, special consequential,
exemplary, or punitive damages, including lost profits, arising from the use of or
inability to consequential or incidental damages.
This Limited Warranty gives you special legal rights and you may also have other
right, which vary from State to State.
Installation
Advan makes no warranty with respect to any installation of Advan’s product(s)
by Advan, any authorized dealer, or any other person.
Technical Assistance
For technical assistance please call (510)490-1005 between 8:00 a.m. and 5:00 p.m. PST,
Monday through Friday or email to support@advancorp.com with a description of your technical issues.
Service
If your Medical Monitor needs service, call Advan Customer Service / RMA at (510)490-1005
between 7:00 a.m and 4:00 p.m PST, Monday through Friday or fax to (510)490-1151. You
will need the unit’s serial number and a brief description of the problem and where unit were
purchased to receive a RMA number.
If a service is required please return the product for service using the original shipping container with the RMA number included in package on the outside of the box.
In order to protect ADVAN employees form potential health hazards, ADVAN requires
that the RMA product be disinfected before returning to ADVAN for service. Any product not cleaned prior to shipment will be returned to the customer.
Note: Returns will not be accepted without an assigned RMA number.
In-transit damage is not covered by warranty. We suggest you always insure your
shipment. Advan will only pay for the return shipment by surface transportation. It is
the responsibility of the sender to prepay transportation charges.
ENGLISH
AMM190WTD 35
ADVAN INT’L CORP
47817 Fremont Blvd. Fremont, CA 94538, USA
Tel : 510-490-1005
Fax : 510-490-1151
Web Page : http://www.advancorp.com
ADVAN Korea
150-871 서울시 영등포구 여의도동
14-24 삼보호정빌딩 2층 210호
Tel : 02.783.5197
Fax : 02.783.5196

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : ericlau
Create Date                     : 2009:11:18 18:31:02-08:00
Modify Date                     : 2009:12:11 15:02:15+09:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Metadata Date                   : 2009:12:11 15:02:15+09:00
Format                          : application/pdf
Title                           : AMM190WTD RevA1 111809.indd
Creator                         : ericlau
Document ID                     : uuid:e97d2df4-7532-4d01-9540-9130b8a330bc
Instance ID                     : uuid:20e198d5-e3d7-48fe-85f4-a950c7a5c317