BARCO AMM213TD2 LCD Color Medical Monitor Model - AMM213TD2 User Manual 20151228 v1 AMM213TD2 RevA Eng
Advan Int'l Corp. LCD Color Medical Monitor Model - AMM213TD2 20151228 v1 AMM213TD2 RevA Eng
BARCO >
User Manual_20151228_v1 - User manual_AMM213TD2 RevA_Eng





























![Power frequency (50/60Hz) mag-netic eld IEC 61000-4-8 3.0 A/m 3.0 A/mPower frequency mag-netic elds should be at levels characteristic of a typical location in a typical commercial or hospital environment.Voltage dips, short interruptions and voltage variations on power supply input lines IEC61000-4-11<5% Ut (>95% dip in Ut) for 0.5 cycle40% Ut (60% dip in Ut) for 5 cycles70% Ut (30% dip in Ut) for 25 cycles<5% Ut (>95% dip in Ut) for 5 sec.<5% Ut (>95% dip in Ut) for 0.5 cycle40% Ut (60% dip in Ut) for 5 cycles70% Ut (30% dip in Ut) for 25 cycles<5% Ut (>95% dip in Ut) for 5 sec.Mains power quaility should be that of a typical commercial or hospital environment. If the user of the AMM213TD2 im-age intensier requires continued operation dur-ing power mains interrup-tions, it is recommended that the AMM213TD2 image intensier be powered from an uninter-ruptible power supply or a battery.Note: Ut is the A.C. mains voltage prior to application of the test level.The Model AMM213TD2 is intended for use in the electromagnetic environment specied below. The customer or the user of AMM213TD2 should ensure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic environment - guidanceConducted RFIEC61000-4-6Radiated RFIEC 61000-4-33 Vrms 150 KHz to 80 MHz3 V/m 80MHz to 2.5 GHz3 Vrms 150 KHz to 80 MHz3 V/m 80MHz to 2.5 GHzPortable and mobile RF communications equipment should be used no closer to any part of the AMM213TD2, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.Recommended Separation Distance0.15 MHz to 80 MHz80 MHz to 800 MHz800 MHz to 2.5 GHzwhere P is the maximum oputput power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m).Field strengths from xed RF transmitters, as deter-mined by an electromagnetic site survey (a), should be less than the compliance level in each frequency range (b).Interferency may occur in the vicinity of equipment marked with the follwing symbol:NOTE 1: At 80MHz and 800MHz, the higher frequency range applies.NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reection from structures, objects, and people.(a) Field strengths from xed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast, connot be predicted theoretically with accuracy. To assess the electromagnetic environment due to xed RF transmitters, an electromagnetic site survey should be considered. If the measured eld strength in the location in which the AMM213TD2 is used exceeds the applicable RF compliance level above, the AMM213TD2 should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the AMM213TD2.(b) Over the frequency range 150kHz to 80MHz, eld strengths should be less than [V1] V/m.Manufacturer’s declaration - electromagnetic immunityAMM213TD2 29](https://usermanual.wiki/BARCO/AMM213TD2/User-Guide-2863232-Page-30.png)







