BARTEC HFG2 RFID Reader User Manual Software Installation
BARTEC RFID Reader Software Installation
BARTEC >
Contents
- 1. User manual
- 2. user manual
user manual
RFID Snap On Modul Content Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004 User Manual RFID Snap On Module RFID LF Reader RFID HF Reader RFID UHF (EU) Reader RFID UHF (US) Reader Document no. B1-A2Z0-7M0003 Revision 1 / June, 20th 2013 Reservation: Technical data subject to change without notice. Changes, errors and misprints may not be used as a basis for any claim for damages. Contents Page English 1 - 12 Appendix Declaration of Conformity Certificate of Compliance 1/12 RFID Snap On Modul Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004 1. Basic Safety Instructions 1.1 Notes on this manual ..................................................................................................... 3 2. Warnings for Use of Wireless Devices 2.1 Radio Frequency Interference Requirements - FCC ..................................................... 4 2.2 Radio Frequency Interference Requirements - Canada ................................................ 5 3. Product Description 3.1 Operation ....................................................................................................................... 6 3.1.1 Exclusive Purpose ........................................................................................... 6 3.1.2 Site of Operation.............................................................................................. 7 4. Technical Data 4.1 Certification.................................................................................................................... 8 4.2 Characteristics ............................................................................................................... 8 4.2.1 Physically Characteristic.................................................................................. 8 4.2.2 User Environment ............................................................................................ 9 4.2.3 Supported RFID Standards ............................................................................. 9 4.3 External Interface ........................................................................................................ 10 4.4 Product Marking .......................................................................................................... 10 5. Commissioning and Operation 11 5.1 Requirements inside of hazardous location ................................................................. 11 5.2 Composition................................................................................................................. 12 6. Order Number 12 6.1 RFID Snap On module for hazardous location ............................................................ 12 6.2 RFID Snap On Module for industrial environment ....................................................... 12 Content 2/12 RFID Snap On Modul Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004 1. Basic Safety Instructions 1.1 Notes on this manual Product description Please read carefully before commissioning the devices.. The user manual is a constituent part of the product. It must be kept in the direct vicinity of the device and accessible at all times to installation, operating and maintenance personnel. It contains important notes, safety instructions and test certificates which are necessary for perfect functioning when the devices are being operated and handled. The user manual is written for all people who carry out assembly, installation, commissioning and maintenance work on the product, whereby the directives and standards applicable to areas with a gas or dust atmosphere (99/92/EC, EN 60079-17, EN 60079-19, IEC 60079-17, IEC 60079-19) must be observed when doing such work. Familiarity with and strict adherence to the safety instructions and warnings in this manual are essential for safe installation and commissioning. Careful handling and consistent observation of these instructions can prevent accidents, personal injuries and damage to property. The illustrations in these operating instructions serve to make the information and descriptions more clear. They are not necessarily true to scale and may deviate slightly from the actual construction of the device. Safety instructions and warnings are specially highlighted in this manual and marked by symbols. DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNUNG WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. ATTENTION ATTENTION identifies a potentially damaging situation which, if not avoided, could damage the equipment or something in its environment. Important instructions and information on effective, economical and environmentally compatible handling. 3/12 RFID Snap On Modul Product description Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004 2.2 Radio Frequency Interference Requirements - Canada This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Radio Transmitters This device complies with RSS 210 of Industry & Science Canada. Operation is subject to the following two conditions: (1) (2) this device may not cause harmful interference and this device must accept any interference received, including interference that may cause undesired operation. Label Marking: The Term "IC:" before the radio certification only signifies that "Industry Canada" technical specifications were met. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. 5/12 RFID Snap On Modul Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004 Product description 3. Product Description Available for: Industrial Environment ATEX/IECEx Zone 2 and Zone 22 UL Class I, II, III Division 2 3.1 Operation 3.1.1 Exclusive Purpose The RFID Snap On Module is a accessory. The modules read and write data on RFID tags in industrial and hazardous locations. It is used exclusively in combination with operating devices which satisfy the requirements for overvoltage category I. 6/12 RFID Snap On Modul Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004 3.1.2 Product description Site of Operation The RFID Snap On Module type G7-A0Z0-…., has been modified for use in following environment: Industrial environment outside of hazardous location The RFID Snap On Module type G7-A0Z0-…., may not be used in locations of: Hazardous location The RFID Snap On Module type B7-A2Z0-…., has been modified for use in following environment: ATEX/IECEx Zone 2 and Zone 22 UL Class I Division 2 Groups A, B, C and D UL Class II Division 2 Groups F and G UL Class III The RFID Snap On Module type B7-A2Z0-…., may not be used in locations of: ATEX/IECEx Zone 0 ATEX/IECEx Zone 1 and Zone 21 UL Class I Division 1 UL Class II Division 1 7/12 RFID Snap On Modul Product description Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004 4. Technical Data 4.1 Certification For hazardous location Type B7-A2Z0-0020 B7-A2Z0-0021 B7-A2Z0-0022 B7-A2Z0-0023 Ex protection type ATEX II 3G Ex ic IIC T6 Gc II 3D Ex ic IIIC T80°C Dc Ex protection type UL Class I Division 2 Gruppen A, B, C and D Class II Division 2 Gruppen F and G Class III Ambient temperature -20 °C ≤ Ta ≤ +50 °C Temperature class T6 Certification ATEX xxxx Certification UL xxxx For industrial environment Type G7-A0Z0-0001 G7-A0Z0-0002 G7-A0Z0-0003 G7-A0Z0-0004 Protection type Ambient temperature -20 °C ≤ Ta ≤ +50 °C Temperature class T6 Certification xxxx 4.2 Characteristics 4.2.1 Physically Characteristic Dimensions Weight Length x width x depth 80 x 61 x 31 mm 3,15 x 2,4 x 1,22 inch approx. 75 g approx. 0,165 oz 8/12 RFID Snap On Modul Product description Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004 4.2.2 4.2.3 User Environment Ambient temperature -20 °C up to +50 °C -4 °F up to +122 °F Storage temperature -40 °C up to +70 °C -40 °F up to +158 °F outside of hazardous location Humidity 5 % up to 95 % (non-condensing) Protection type (EN 60529) IP 54 (with adapter plate) Supported RFID Standards LF Reader Type: B7-A2Z0-0020 Type: G7-A0Z0-0001 HITAG S256 ISO 117845 HITAG S 2 kb ISO Animal HITAG 1 ISO 11784/5 HITAG 2 EM 4450/4550 Q5 EM4xxx (UNIQUE) ATA5567 HDX -RO EM4305 HDX (Multipage) BDE FDX-B HF Reader Type: B7-A2Z0-0021 Type: G7-A0Z0-0002 UHF EU und US Reader Type: B7-A2Z0-0022 Type: B7-A2Z0-0023 Type: G7-A0Z0-0003 Type: G7-A0Z0-0004 ISO 14443 (z.B. Mifare Ultralight) EPC Gen 2 ISO 15693 9/12 RFID Snap On Modul Product description Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004 4.3 External Interface Pins on the connector: +++++ PIN 4.4 Description PIN Description Ground USB_DPin Reserved USB_D+ 5.4 VDC USB_Vbus Cradle_Detect Reserved Power Gnd 10 USB_ID Product Marking Type number Marking for ex proofed Version Marking for Industrial Version Type: B7-A2Z0-… Type: G7-A0Z0-…. Type: B7-A2Z0-0020 Type: G7-A0Z0-0001 Type: B7-A2Z0-0021 Type: G7-A0Z0-0002 Type: B7-A2Z0-0023 Type: G7-A0Z0-0003 Type: B7-A2Z0-0022 Type: G7-A0Z0-0004 10/12 RFID Snap On Modul Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004 Product description 5. Commissioning and Operation DANGER Avoid electrostatic charge inside of hazardous location. There is a risk of fatal injury in an explosive atmosphere! Don’t dry clean or wipe. Wear suitable clothes and shoes. Don’t use rubber gloves. DANGER Inproper use is a risk for the explosion protection. There is a risk of fatal injury in an explosive atmosphere! The user may not make any alterations to the module. If a function error or a damage on the enclosure occurs then bring the device with the module immediately outside of the hazardous location and switch it off. DANGER Not certified accessories are a risk for the explosion protection. There is a risk of fatal injury in an explosive atmosphere! Use only original accessories from BARTEC. Only allowed outside of the hazardous location: 5.1 Snap on, release and remove of the module Requirements inside of hazardous location Don’t open it! Don’t use, change or replace not specified! Protect the device from impact effects! Do not expose the equipment to any caustic/aggressive liquids, vapours or mist! Avoid the effects of moisture! Avoid the influence of heat that is outside of the specified temperature range! Snap on of the 10-pin data interface is only permissible outside the hazardous area and only with devices specified by the manufacturer! 11/12 RFID Snap On Modul Product description Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004 5.2 Composition Label location 6. Order Number 6.1 6.2 RFID Snap On module for hazardous location Order number: Version: Type: Frequency range: B7-A2Z0-0020 Ex RFID LF Reader 125 kHz / 134 kHz B7-A2Z0-0021 Ex RFID HF Reader 13,56 MHz B7-A2Z0-0022 Ex RFID UHF (US) Reader 902 up to 928 MHz B7-A2Z0-0023 Ex RFID UHF (EU) Reader 865,6 up to 867,5 MHz RFID Snap On Module for industrial environment Order number: Version: Type: Frequency range: G7-A0Z0-0001 Industry RFID LF Reader 125 kHz / 134 kHz G7-A0Z0-0002 Industry RFID HF Reader 13,56 MHz G7-A0Z0-0003 Industry RFID UHF (EU) Reader 865,6 up to 867,5 MHz G7-A0Z0-0004 Industry RFID UHF (US) Reader 902 up to 928 MHz 12/12 RFID Snap On Modul Product description Type B7-A2Z0-0020 to 0023 and G7-A0Z0-0001 to 0004 7. Compliance Information Statement Compliance Information Statement (Declaration of Conformity Procedure) Responsible Party: BARTEC US Corp Address: 600 Century Plaza Drive Suite C160 Houston, TX 77073 USA Telephone: + 1 281 214 8542 Type of Equipment: RFID Snap On Module Type B7-A2Z0-0020, -0021 and -0022 and G7-A0Z0-0001, -0002 and -0004 Model Name: RFID LF Snap On Module RFID HF Snap On Module RFID UHF (US) Snap On Module FCC ID: TBULFG2 FCC ID: TBUHFG2 FCC ID: TBUUHFG2 12/12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Bassiener Gabriela Create Date : 2013:06:20 11:31:03Z Modify Date : 2013:06:25 11:52:31+02:00 Language : de-DE Tagged PDF : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : Bassiener Gabriela Title : Software Installation Creator Tool : Microsoft® Office Word 2007 Metadata Date : 2013:06:25 11:52:31+02:00 Producer : Microsoft® Office Word 2007 Document ID : uuid:f8ea5c33-c696-4420-9290-9771f4424d76 Instance ID : uuid:3a70127a-7e19-49fa-aa38-5e1202ced8c1 Page Count : 13EXIF Metadata provided by EXIF.tools