BEA 75.5867.03 REMOTE CONTROL INDUSTRIAL 20160211 Cheat Sheet Universal

User Manual: BEA Cheat Sheet - BEA Universal Remote User Guide

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadBEA 75.5867.03 REMOTE CONTROL INDUSTRIAL 20160211 Cheat Sheet - Universal
Open PDF In BrowserView PDF
UNIVERSAL REMOTE CONTROL

|

LZR-I30/S600

L Z R - I 3 0 / S 6 0 0 PA R A M E T E R S

UNIVERSAL REMOTE CONTROL TIPS

# O F A C T I V E D E T E C T I O N C U R TA I N S

T O C H A N G E O R Q U E S T I O N A PA R A M E T E R ,
S TA R T B Y P R E S S I N G T H E
AND FINISH
THE SESSION BY PRESSING

E X A M P L E C O N F I G U R AT I O N S
CURTAIN

C1

C2

C3

C4

CURTAIN IS INACTIVE ON BOTH FIELDS

C1 + C2 ARE ACTIVE ON SAFETY FIELD
C3 + C4 ARE ACTIVE ON OPTIONAL FIELD

CURTAIN IS ACTIVE ON OPTIONAL FIELD

C1 IS ACTIVE ON BOTH FIELDS
C2 + C3 ARE ACTIVE ON SAFETY FIELD
C4 IS INACTIVE

The distances between the curtains depends on the mounting height and side.
When mounted on the left, the distance between curtain C1 and curtain C4 is approximately 4 in. for every 3 ft (mounting height).
EXAMPLE: At 15 ft. mounting height, the distance between C1 and C4 is 20 in.

CURTAIN IS ACTIVE ON SAFETY FIELD
CURTAIN IS ACTIVE ON BOTH FIELDS

T O Q U E S T I O N A PA R A M E T E R , P R E S S
AFTER UNLOCKING AND CHOOSING A
PA R A M E T E R . C O U N T T H E L E D F L A S H E S .
CONSIDER USING AN ACCESS CODE
T O S E T A N A CCE S S COD E :

MOUNTING SIDE

left

ALL CURTAINS ARE ACTIVE ON BOTH FIELDS

right

left

WITH BACKGROUND

right

T O D E LE T E A N A CCE S S COD E :

center

WITHOUT BACKGROUND

V I R T U A L P U S H P L AT E :

UNCOVERED ZONE

F A C T O R Y D E F A U LT S :
2in

4in

6in

8in

A LW AY S F I N I S H A N A D J U S T M E N T S E S S I O N
BY LAUNCHING A SETUP:

10 i n

Increase in case of snow, dead leaves, etc.

TO TURN THE LEDs ON/OFF:

O U T P U T A C T I VAT I O N D E L AY
OFF

100ms

200ms

300ms

FOR VISIBLE LASER BEAMS:

400ms

500ms

600ms

700ms

800ms

900ms

The relays are triggered when the detection duration ≥ the selected time.

OPTIONAL FIELD WIDTH

I M M U N I T Y F I LT E R
indoor

outdoor
low

outdoor
med

OPTIONAL FIELD HEIGHT
outdoor
high

outdoor
low

indoor

FOR CRITICAL ENVIRONMENTS
(RAIN, SNOW, FOG)

outdoor
med

SAFETY FIELD WIDTH

outdoor
high

SAFETY FIELD HEIGHT

FOR CRITICAL OBJECTS
(BLACK CARS)

Choose between environment or object.

LZR TIPS

MINIMUM OBJECT SIZE

THE LZR-I30REQUIRES 10-35 V CLEAN DC POWER
(NON-RECTIFIED)
OFF

3in

4in

6in

8in

AFTER 30 MINUTES, THE SENSOR LOCKS ACCESS TO

O U T P U T C O N F I G U R AT I O N

THE REMOTE CONTROL SESSION. POWER CYCLE THE
SENSOR TO RECONFIGURE.

R1

A - NO

P - NC

P - NC

A - NO

A = active
P = passive

R2

P - NC

A - NO

P - NC

A - NO

NO = normally open
NC = normally closed

A BEA UNIVERSAL REMOTE IS REQUIRED TO
CONFIGURE THE LZR-I30.

24/7 Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: Tech_Services@beainc.com | Tech Docs: www.beasensors.com

75.5867.03 REMOTE CONTROL INDUSTRIAL 20160211		

Page 1 of 2

UNIVERSAL REMOTE CONTROL

|

FA L C O N & I S 4 0 S E R I E S
UNIVERSAL REMOTE CONTROL TIPS

M I C R O W A V E PA R A M E T E R S

T O C H A N G E O R Q U E S T I O N A PA R A M E T E R ,
S TA R T B Y P R E S S I N G T H E
AND FINISH
THE SESSION BY PRESSING

SENSITIVITY
XXS

XS

S

>

>

>

>

L

XL

XXL

6s

7s

8s

9s

T O Q U E S T I O N A PA R A M E T E R , P R E S S
AFTER UNLOCKING AND CHOOSING A
PA R A M E T E R . C O U N T T H E L E D F L A S H E S .

A C T I VAT I O N R E L AY H O L D T I M E
0.5 s

1s

2s

3s

4s

5s

CONSIDER USING AN ACCESS CODE
T O S E T A N A CCE S S COD E :

DETECTION MODE
bi

uni

bi = two-way detection
uni = one-way detection towards sensor
uni depart = one-way detection away from sensor

uni
depart

T O D E LE T E A N A CCE S S COD E :

REJECTION MODE
1

2

3

4

5

6

R E L AY C O N F I G U R AT I O N :

NOTES FACTORY DEFAULTS

1: DETECTION OF ALL KINDS OF TARGETS IN MOTION
2: DETECTION OF ALL KINDS OF TARGETS IN MOTION + INTERFERENCE IMMUNITY
3: LOW ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY
4: MEDIUM ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY
5: HIGH ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY
6: HIGHEST ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY

1-4

F A C T O R Y D E F A U LT S :
A LW AY S F I N I S H A N A D J U S T M E N T S E S S I O N
BY LAUNCHING A SETUP:

I N F R A R E D PA R A M E T E R S

FREQUENCY
low

high

low

medium

L E A R N T I M E E X P L A N AT I O N

IR IMMUNITY
IF AN OBJECT IS IN THE PRESENCE DETECTION FIELD AND REMAINS MOTIONLESS FOR LONGER
THAN THE PROGRAMMED LEARN TIME, THE SENSOR WILL ACCEPT THE OBJECT AS PART OF
ITS BACKGROUND/REFERENCE POINT AND WILL DROP THE DETECTION SIGNAL.

high

A U T O M AT I C L E A R N T I M E
30s

1 min

2 min

5 min

10 min

20 min

1h

1.5 h

2h

I R PAT T E R N S I Z E
1

DOOR

2

DOOR

**INFINITY (

∞

∞ ) WILL NEVER LEARN A NEW BACKGROUND**

I R TA R G E T S I Z E
3

DOOR

4

DOOR

5

DOOR

DOOR

DOOR

DOOR

DOOR

2x2
1x2
6

DOOR

7

DOOR

8

DOOR

1x1

3x2

3x3

4x4

9

DOOR

24/7 Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: Tech_Services@beainc.com | Tech Docs: www.beasensors.com

Page 2 of 2		

75.5867.03 REMOTE CONTROL INDUSTRIAL 20160211



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.6-c067 79.157747, 2015/03/30-23:40:42
Create Date                     : 2016:02:11 14:55:56-05:00
Metadata Date                   : 2016:02:11 14:55:58-05:00
Modify Date                     : 2016:02:11 14:55:58-05:00
Creator Tool                    : Adobe InDesign CC 2015 (Macintosh)
Instance ID                     : uuid:e52c0094-e9a3-b140-8db4-b2c30f78e02e
Original Document ID            : xmp.did:3DC0279A5095E211B5A3E4D6F5E241D6
Document ID                     : xmp.id:8d8a152e-d891-4e73-9ac5-13e620076c13
Rendition Class                 : proof:pdf
Version ID                      : 1
Derived From Instance ID        : xmp.iid:bfd517df-fab9-4fd6-9623-713fdbc198b8
Derived From Document ID        : xmp.did:2d066dbb-8f49-449c-80a4-78cd24e85f18
Derived From Original Document ID: xmp.did:3DC0279A5095E211B5A3E4D6F5E241D6
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Macintosh)
History Changed                 : /
History When                    : 2016:02:11 14:55:56-05:00
Format                          : application/pdf
Title                           : 75.5867.03 REMOTE CONTROL INDUSTRIAL 20160211.indd
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
GTS PDFX Version                : PDF/X-4
Page Count                      : 2
Creator                         : Adobe InDesign CC 2015 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu