BEA 75.5867.03 REMOTE CONTROL INDUSTRIAL 20160211 Cheat Sheet Universal
User Manual: BEA Cheat Sheet - BEA Universal Remote User Guide
Open the PDF directly: View PDF
.
Page Count: 2
| Download | |
| Open PDF In Browser | View PDF |
UNIVERSAL REMOTE CONTROL | LZR-I30/S600 L Z R - I 3 0 / S 6 0 0 PA R A M E T E R S UNIVERSAL REMOTE CONTROL TIPS # O F A C T I V E D E T E C T I O N C U R TA I N S T O C H A N G E O R Q U E S T I O N A PA R A M E T E R , S TA R T B Y P R E S S I N G T H E AND FINISH THE SESSION BY PRESSING E X A M P L E C O N F I G U R AT I O N S CURTAIN C1 C2 C3 C4 CURTAIN IS INACTIVE ON BOTH FIELDS C1 + C2 ARE ACTIVE ON SAFETY FIELD C3 + C4 ARE ACTIVE ON OPTIONAL FIELD CURTAIN IS ACTIVE ON OPTIONAL FIELD C1 IS ACTIVE ON BOTH FIELDS C2 + C3 ARE ACTIVE ON SAFETY FIELD C4 IS INACTIVE The distances between the curtains depends on the mounting height and side. When mounted on the left, the distance between curtain C1 and curtain C4 is approximately 4 in. for every 3 ft (mounting height). EXAMPLE: At 15 ft. mounting height, the distance between C1 and C4 is 20 in. CURTAIN IS ACTIVE ON SAFETY FIELD CURTAIN IS ACTIVE ON BOTH FIELDS T O Q U E S T I O N A PA R A M E T E R , P R E S S AFTER UNLOCKING AND CHOOSING A PA R A M E T E R . C O U N T T H E L E D F L A S H E S . CONSIDER USING AN ACCESS CODE T O S E T A N A CCE S S COD E : MOUNTING SIDE left ALL CURTAINS ARE ACTIVE ON BOTH FIELDS right left WITH BACKGROUND right T O D E LE T E A N A CCE S S COD E : center WITHOUT BACKGROUND V I R T U A L P U S H P L AT E : UNCOVERED ZONE F A C T O R Y D E F A U LT S : 2in 4in 6in 8in A LW AY S F I N I S H A N A D J U S T M E N T S E S S I O N BY LAUNCHING A SETUP: 10 i n Increase in case of snow, dead leaves, etc. TO TURN THE LEDs ON/OFF: O U T P U T A C T I VAT I O N D E L AY OFF 100ms 200ms 300ms FOR VISIBLE LASER BEAMS: 400ms 500ms 600ms 700ms 800ms 900ms The relays are triggered when the detection duration ≥ the selected time. OPTIONAL FIELD WIDTH I M M U N I T Y F I LT E R indoor outdoor low outdoor med OPTIONAL FIELD HEIGHT outdoor high outdoor low indoor FOR CRITICAL ENVIRONMENTS (RAIN, SNOW, FOG) outdoor med SAFETY FIELD WIDTH outdoor high SAFETY FIELD HEIGHT FOR CRITICAL OBJECTS (BLACK CARS) Choose between environment or object. LZR TIPS MINIMUM OBJECT SIZE THE LZR-I30REQUIRES 10-35 V CLEAN DC POWER (NON-RECTIFIED) OFF 3in 4in 6in 8in AFTER 30 MINUTES, THE SENSOR LOCKS ACCESS TO O U T P U T C O N F I G U R AT I O N THE REMOTE CONTROL SESSION. POWER CYCLE THE SENSOR TO RECONFIGURE. R1 A - NO P - NC P - NC A - NO A = active P = passive R2 P - NC A - NO P - NC A - NO NO = normally open NC = normally closed A BEA UNIVERSAL REMOTE IS REQUIRED TO CONFIGURE THE LZR-I30. 24/7 Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: Tech_Services@beainc.com | Tech Docs: www.beasensors.com 75.5867.03 REMOTE CONTROL INDUSTRIAL 20160211 Page 1 of 2 UNIVERSAL REMOTE CONTROL | FA L C O N & I S 4 0 S E R I E S UNIVERSAL REMOTE CONTROL TIPS M I C R O W A V E PA R A M E T E R S T O C H A N G E O R Q U E S T I O N A PA R A M E T E R , S TA R T B Y P R E S S I N G T H E AND FINISH THE SESSION BY PRESSING SENSITIVITY XXS XS S > > > > L XL XXL 6s 7s 8s 9s T O Q U E S T I O N A PA R A M E T E R , P R E S S AFTER UNLOCKING AND CHOOSING A PA R A M E T E R . C O U N T T H E L E D F L A S H E S . A C T I VAT I O N R E L AY H O L D T I M E 0.5 s 1s 2s 3s 4s 5s CONSIDER USING AN ACCESS CODE T O S E T A N A CCE S S COD E : DETECTION MODE bi uni bi = two-way detection uni = one-way detection towards sensor uni depart = one-way detection away from sensor uni depart T O D E LE T E A N A CCE S S COD E : REJECTION MODE 1 2 3 4 5 6 R E L AY C O N F I G U R AT I O N : NOTES FACTORY DEFAULTS 1: DETECTION OF ALL KINDS OF TARGETS IN MOTION 2: DETECTION OF ALL KINDS OF TARGETS IN MOTION + INTERFERENCE IMMUNITY 3: LOW ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY 4: MEDIUM ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY 5: HIGH ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY 6: HIGHEST ‘PEDESTRIAN/PARALLEL TRAFFIC’ REJECTION + INTERFERENCE IMMUNITY 1-4 F A C T O R Y D E F A U LT S : A LW AY S F I N I S H A N A D J U S T M E N T S E S S I O N BY LAUNCHING A SETUP: I N F R A R E D PA R A M E T E R S FREQUENCY low high low medium L E A R N T I M E E X P L A N AT I O N IR IMMUNITY IF AN OBJECT IS IN THE PRESENCE DETECTION FIELD AND REMAINS MOTIONLESS FOR LONGER THAN THE PROGRAMMED LEARN TIME, THE SENSOR WILL ACCEPT THE OBJECT AS PART OF ITS BACKGROUND/REFERENCE POINT AND WILL DROP THE DETECTION SIGNAL. high A U T O M AT I C L E A R N T I M E 30s 1 min 2 min 5 min 10 min 20 min 1h 1.5 h 2h I R PAT T E R N S I Z E 1 DOOR 2 DOOR **INFINITY ( ∞ ∞ ) WILL NEVER LEARN A NEW BACKGROUND** I R TA R G E T S I Z E 3 DOOR 4 DOOR 5 DOOR DOOR DOOR DOOR DOOR 2x2 1x2 6 DOOR 7 DOOR 8 DOOR 1x1 3x2 3x3 4x4 9 DOOR 24/7 Tech Support: 1-800-407-4545 | Customer Service: 1-800-523-2462 | General Tech Questions: Tech_Services@beainc.com | Tech Docs: www.beasensors.com Page 2 of 2 75.5867.03 REMOTE CONTROL INDUSTRIAL 20160211
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : Adobe XMP Core 5.6-c067 79.157747, 2015/03/30-23:40:42 Create Date : 2016:02:11 14:55:56-05:00 Metadata Date : 2016:02:11 14:55:58-05:00 Modify Date : 2016:02:11 14:55:58-05:00 Creator Tool : Adobe InDesign CC 2015 (Macintosh) Instance ID : uuid:e52c0094-e9a3-b140-8db4-b2c30f78e02e Original Document ID : xmp.did:3DC0279A5095E211B5A3E4D6F5E241D6 Document ID : xmp.id:8d8a152e-d891-4e73-9ac5-13e620076c13 Rendition Class : proof:pdf Version ID : 1 Derived From Instance ID : xmp.iid:bfd517df-fab9-4fd6-9623-713fdbc198b8 Derived From Document ID : xmp.did:2d066dbb-8f49-449c-80a4-78cd24e85f18 Derived From Original Document ID: xmp.did:3DC0279A5095E211B5A3E4D6F5E241D6 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Macintosh) History Changed : / History When : 2016:02:11 14:55:56-05:00 Format : application/pdf Title : 75.5867.03 REMOTE CONTROL INDUSTRIAL 20160211.indd Producer : Adobe PDF Library 15.0 Trapped : False GTS PDFX Version : PDF/X-4 Page Count : 2 Creator : Adobe InDesign CC 2015 (Macintosh)EXIF Metadata provided by EXIF.tools