BEA 79.0198.06 KEYPADS 20151005 Cut Sheet Keypad

User Manual: BEA Cut Sheet - Keypad Cut Sheet

Open the PDF directly: View PDF PDF.
Page Count: 2

BEA, Inc.
RIDC Park West
100 Enterprise Drive
Pittsburgh, PA 15275-1213
Customer Service: 800.523.2462
Technical Support: 800.407.4545
www.BEAinc.com
FEATURES & BENEFITS
Allows for up to 120 individual user codes
Codes can be one to six digits in length with
repeats
Input trigger for security or other open circuit
contact
Keypress feedback acknowledgment is indicated
by a yellow LED
4 independent output and 4 independent timers
assignable by code
3 additional outputs with accessory board
(sold separately)
Available in standard indoor or weather-resistant
outdoor models
DESCRIPTION
BEAs Keypads offer field-proven reliability and
cost effective solutions anywhere access control
is desired. These keypads are designed for basic
access or code control for up to four individual
devices. They are ideal for integration into security
systems with electromagnetic locks, electric strikes,
restricted access elevators or gates and other types
of equipment requiring on/off or momentary
control inputs.
All programming is completed entirely from the
keypad. Non-volatile memory means codes and
instructions will remain with power removed.
PRIMARY APPLICATIONS
ACCESS CONTROL KEYPADS FOR INDOOR AND OUTDOOR USE
KEYPADS
SHOWN ABOVE
Standard Indoor Keypad (LEFT) and
Weather-Resistant, Outdoor Keypad (RIGHT)
79.0198.06 20151005
2.75 in
4.5 in
www.BEAinc.com
Customer Service: 800.523.2462
Technical Support: 800.407.4545
BEA, Inc.
RIDC Park West
100 Enterprise Drive
Pittsburgh, PA 15275-1213
PRODUCT FAMILY
10KEYPAD
STANDARD INDOOR
KEYPAD
10KEYPADWR
WEATHER-RESISTANT,
OUTDOOR KEYPAD
KEYPADS ACCESS CONTROL KEYPADS FOR INDOOR AND OUTDOOR USE
TECHNICAL SPECIFICATIONS
DIMENSIONAL DRAWINGS
Faceplate Dimensions Single - 2.75 in x 4.5 in x .44 in
Materials Brushed aluminum faceplate
Current
8 mA @ 12 VDC; 35 mA with relay energized
16 mA @ 24 VDC; 45 mA with relay energized
21 mA @ 12 VDC; 74 mA with relay energized
43 mA @ 24 VDC; 91 mA with relay energized
Time Range
(user adjustable) 1 to 90 s
Output Main relay: 5 A @ 24 VDC with 10 A Surge
Outputs 2, 3 & 4 are 50 mA (-V) output
Relay Form C relay; timed output or toggle (latch)
Voltage 12 to 24 V AC/DC (no jumper required)
Operating Temperature -20ºF to +13F
RELATED REQUEST TO EXIT PRODUCTS