BEA 79.0026.14 BR3 X 20180814 Logic Module Cut Sheet

User Manual: BEA BEA Br3-X Logic Module Cut Sheet Cut Sheet

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadBEA 79.0026.14 BR3-X 20180814 Logic Module Cut Sheet Br3-x-cut-sheet
Open PDF In BrowserView PDF
BR3-X

PROGRAMMABLE 3-RELAY LOGIC MODULE

PRIMARY APPLIC ATIONS

1

BR3-X Receives Input

2

BR3-X Relay 1
Releases Maglock

3

BR3-X Relay 2
Activates Door

PUSH
TO OPEN

DESCRIPTION

OCCUPIED
WHEN
LIT

FEATURES & BENEFITS

BEA’s BR3-X provides both simple and advanced logic
controls.

•

Versatility with 13 programmable logic
functions for the BR3-X

Functions include: timer, ratchet/latching, inhibitor, 2
relay sequencer + inhibitor, 2 relay sequencer + door
position deactivation timer, 3 relay sequencer + “1shot”, 3 relay sequencer with “independent relay”,
interlock timer, interlock ratchet / latching, 2 way 2
relay sequence, normally locked restroom, normally
unlocked restroom, 3 relay sequencer + “day / night
mode”.

•

Two-button programming combined with dual
seven-segment display provides simple setup

•

Two 3-AMP relays and one 1-AMP relay, all
with built-in surge suppression, eliminates the
need for external components when installing
some electric locking devices

•

WET output with AC / DC voltage for powering
an electric locking device directly from the
module

Common uses for the Br3-X include automatic
pedestrian doors, access control, industrial
automation and single-occupancy restrooms.

BEA, Inc.
RIDC Park West
100 Enterprise Drive
Pittsburgh, PA 15275-1213

Customer Service: 800.523.2462
Technical Support: 800.407.4545
www.BEAinc.com

APPLIC ATIONS
SLIDING

SWINGING

GATES AND BARRIERS

LOW ENERGY

RESTROOM EMERGENCY

DAY / NIGHT MODE

REQUEST-TO-EXIT

IN THE EVENT OF AN EMERGENCY
PUSH EMERGENCY BUTTON
AND AUDIBLE AND VISUAL SIGNAL
WILL ACTIVATE

PUSH FOR
ASSISTANCE

ASSISTANCE
REQUESTED

FUNC TION DETAILS
Br3-X FUNCTION

TECHNIC AL SPECIFIC ATIONS

DESCRIPTION

Supply Voltage

12 – 24 VAC / VDC ±10%
30 – 130 mA; DRY Output

10

Timer

Power Consumption

11

Ratchet / Latching

Temperature Range

22

2 Relay Sequence + Inhibitor

28

2 Relay Sequence + Door Position

29

Deactivation Timer

36

3-Relay Sequencer + ‘1-shot’

37

3-Relay Sequence with ‘Independent Relay’

50

Interlock Timer

55

Interlock Ratchet / Latching

65

2-Way, 2 Relay Sequence

nL

Normally Locked Restroom

nU

Normally Unlocked Restroom

dn

3-Relay Sequencer + ‘Day / Night mode’

00

Disable

–15 ºF – 150 ºF*

*If powered by AC voltage and using WET
output to convert to DC voltage and current
draw of device is greater than 0.9 A, the
upper temperature range is 130 ºF

Dimensions

5.2 in (W) × 1.0 in (H) × 2.2 in (D)

Relay Hold Time

Up to 60 seconds per relay

Delay Between Relays

Up to 60 seconds per relay with 1/4, 1/2
and 3/4 second options

Housing Material

ABS Plastic

Input Specification
Inputs 1, 2, 3, 4
WET Input

DRY contact
5 – 24 VAC / VDC ±10%

Contact Rating
3 A @ 24 VAC / 30 VDC

Relay 1 (DRY)
Relay 1 (WET)
Relay 2
Relay 3

1A
3 A @ 24 VAC / 30 VDC
1 A @ 24 VAC / 30 VDC

REL ATED PRODUC TS

10BR3X
3-RELAY LOGIC
MODULE

www.BEAinc.com
© 2018 BEA, Inc. All rights reserved.

79.0026.14

20180813

BR3-X

10RESTROOMKIT
RESTROOM
KIT

PROGRAMMABLE 3-RELAY LOGIC MODULE

BEA, Inc.
RIDC Park West
100 Enterprise Drive
Pittsburgh, PA 15275-1213

Customer Service: 800.523.2462
Technical Support: 800.407.4545

10EMERGENCYKIT
EMERGENCY
ADD-ON KIT



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Language                        : en-US
XMP Toolkit                     : Adobe XMP Core 5.6-c143 79.161424, 2017/09/22-11:52:47
Create Date                     : 2018:08:13 12:34:12-04:00
Metadata Date                   : 2018:08:13 12:34:31-04:00
Modify Date                     : 2018:08:13 12:34:31-04:00
Creator Tool                    : Adobe InDesign CC 13.1 (Macintosh)
Instance ID                     : uuid:93efeb76-46e4-d148-8153-7c77e411df42
Original Document ID            : xmp.did:a2d77d75-0fe1-4608-9b99-390aec0693d9
Document ID                     : xmp.id:186d9f52-e161-4ca6-a004-02457ee51ad9
Rendition Class                 : proof:pdf
Version ID                      : 1
Derived From Instance ID        : xmp.iid:bb1b06c8-e2b6-4f8e-87f1-c0db46e96478
Derived From Document ID        : xmp.did:385c8040-33cf-444d-bcd6-0be5c70a3d67
Derived From Original Document ID: xmp.did:a2d77d75-0fe1-4608-9b99-390aec0693d9
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.1 (Macintosh)
History Changed                 : /
History When                    : 2018:08:13 12:34:12-04:00
Format                          : application/pdf
Title                           : 79.0026.14 BR3-X 20180814.indd
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
GTS PDFX Version                : PDF/X-4
Page Count                      : 2
Creator                         : Adobe InDesign CC 13.1 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu