BELLUS MEDICAL 101 SkinPen Precision Charger User Manual Manual

BELLUS MEDICAL, LLC SkinPen Precision Charger Manual

Manual

Engineered  & Designed  in the USA Made in the USA Inductive Charging SMART Technology Patented  Reciprocating MechanismUser Manual SkinPen® Model #100SkinPen® Charger Base Model #101
Table of Contents   1.  Device Description...............................................................................................2  2.  Intended Use.........................................................................................................4  3.  Contraindications.................................................................................................4  4.  Warnings................................................................................................................4  5.  Precautions............................................................................................................4  6.  Electrical Safety Warnings................................................................................4  7.  Intended Use.........................................................................................................5  8.  Procedure Instructions,   Post-Procedure Instructions,   Post-Procedure Care..........................................................................................7   9.  Cleaning of SkinPen® Precision & Charger Base........................................710. Storage....................................................................................................................7 11. Disposal..................................................................................................................812. Warranty.................................................................................................................813.  FAQ & Troubleshooting......................................................................................8 14. Specifications......................................................................................................1015.  Environmental Conditions..............................................................................101    SkinPen® Precision Rev.V1.0
1. DEVICE DESCRIPTIONThe SkinPen® Precision device consists of a microneedling pen, sterile needle cartridge, and hydrogel. The accessories are a charging base and a BioSheath. Each component and accessory will be explained to understand how SkinPen® Precision works.SkinPen® Precision Key ComponentsA     Power IndicatorB     Power On/Off ButtonC     Charge Level IndicatorD     Microneedling ConnectorE      Ergononic Handle GripF      Base Charger AC/DC AdapterG     Inductive Charging BaseSkinPen® Precision Rev.V1.0    2Fig 1.GFEABCD
INCLUDES:Microneedling CartridgeEO (Ethylene Oxide) Sterilized, disposable  needle cartridge packaged and labeled individually.  Proprietary needle cartridge. BioSheathThe SkinPen® Precision and needle cartridge interface  with a nonsterile and disposable BioSheath to prevent  contamination of the SkinPen® Precision.LIFT HGLift HG is a hydrogel wound dressing without drugs  and/or a biologic to protect against abrasion and friction during the microneedling procedure.RESCUE Calming ComplexKey ingredients assist in reducing the risk of prolonged inflammation post-procedure.NUMB Topical Analgesic Skinfuse® NUMB is a OTC 5g individual pre-procedure packet (4% lidocaine) that will provide patient comfort during the procedure by topically numbing the area  receiving the microneedling procedure. The single-use packet reduces the risk of cross-contamination.SKINPEN® TREATMENT KIT3    SkinPen® Precision Rev.V1.0
2. INTENDED USESkinPen® Precision is a microneedling device to improve the appearance of  fine lines, wrinkles, and scars on the face and body. Rx Only. 3. CONTRAINDICATIONS The use of SkinPen® Precision should not be used on patients with active skin cancer or active bacterial, fungal or viral (i.e. herpes, warts) skin infections in  the treatment area(s).4. WARNINGS SkinPen® Precision has not been evaluated in the following patient populations, and as such, precautions should be taken when determining whether to treat patients with a history of the following conditions: Eczema, psoriasis, and other chronic conditions in the treatment area; herpes simplex infections; keloid scars; patients on anticoagulants; scars and stretch marks less than one year old; scleroderma; and wound-healing deficiencies.5. PRECAUTIONS Universal precautions are necessary during microneedling. Microneedling should not be used within the orbital rim, such as the eyelids. Special care needs to be exercised on patients with the following conditions or on the  following medications: Actinic (solar) keratosis; active acne; allergies to  stainless steel; collagen vascular diseases or cardiac abnormalities; diabetes; eczema, psoriasis and other chronic conditions on other areas of the body; immunosuppressive therapy; irritated skin in the treatment area; history  of contact dermatitis; hemorrhagic disorder or hemostatic dysfunction;  isotretinoin drugs, pregnancy or nursing; open wounds or sores; irritated  skin; raised moles in the treatment area; and rosacea.6. ELECTRICAL SAFETY WARNINGS•  No modification of this equipment is allowed.    Only use included SkinPen® Precision adapter and charger base. •  Do not plug product into outlet with a voltage other than    specified on the charger. (90-264Vac).•  Never force plug into an outlet –    if it does not easily fit into the outlet, discontinue use. •  Discontinue use if product appears damaged in any way. •  Do not use or charge if cord or plug is damaged.•  Keep cord away from heated surfaces.•  Do not store the pen and/or charger base near a    sink or where it can fall or be pulled into water. •  This device complies with Part 15 of the FCC Rules. Operation is   subject to the following two conditions: (1) this device may not   cause harmful interference, and (2) this device must accept any  SkinPen® Precision Rev.V1.0    4
  interference received, including interference that may    cause undesired operation. •  For your safety from electrical shock, the SkinPen® Precision    and/or SkinPen® Precision Charger base should not be opened    or disassembled for trouble-shooting purposes. There are no user      serviceable parts.7. INTENDED USE•  Only use this device for the recommended applications.    This device should only be used under medical supervision.•  Before administering any treatment, you should become acquainted     with the operating procedures for the treatment, as well as the    indications, contraindications, warnings, and precautions. Consult    other resources (ie. IFU) for additional information regarding the    application of microneedling therapy. How to install/uninstall disposable SkinPen cartridge:     • Ensure SkinPen® Precision is powered off.    • Align the lock and key mechanism on the         SkinPen® Precision  microneedling cartridge and         the SkinPen® Precision device.     • Rotate counterclockwise onto the SkinPen® Precision         until secure.    • To remove the cartridge rotate clockwise until         the cartridge is removed.    • The SkinPen® Precision cartridge is designed for single use,         with a lock-out feature prohibiting re-installation of the         cartridge after use.    • Dispose of used SkinPen® Precision cartridge         via a Sharps container.   LOCKUNLOCKMALE FEMALEClear Faults3215    SkinPen® Precision Rev.V1.0
  *If a SkinPen® Precision Cartridge becomes inadvertently      contaminated during installation (ie. Dropped on floor, needles      subjected to possible contamination), discard, and obtain new      SkinPen® Precision cartridge.  Additional SkinPen® Precision Cartridge Instructions: How to adjust needle length:    • To increase the needle length, adjust on the cartridge         according to indicated tick marks on the cartridge.         New settings will be indicated by a “click” into place.     • Needle settings should be selected based on patient needs.     • It is recommended to start at a depth setting of 0.25mm.     • If even erythema (redness) is not seen, gradually increase          the depth to a maximum of 1.5mm on the face and         up to 2.5mm on the body.   *Lower the setting of the cartridge to 0.25-0.5mm to perform the      procedure around the orbital rim.     • Decrease the needle length by adjusting according to the         tick marks on the cartridge. New settings will be indicated         by a “click” into place.How to apply BioSheath:     • While wearing non-latex gloves, obtain a single use         BioSheath and ensure the SkinPen® Precision is         clean/disinfected.      • While SkinPen® Precision is powered off, insert the         SkinPen® Precision between the white tab and paper backing.    • Push SkinPen® Precision through the BioSheath until the         device is snug inside the Biosheath.     • Peel back the protective BioSheath cover by pulling on the         Blue tab and white paper backing.          • Remove adhesive backing and seal end. SkinPen® Precision         is now protected and ready to use.INCREASEDECREASECLICKSkinPen® Precision Rev.V1.0    6ADHESIVEADHESIVE
    • To remove BioSheath simply peel off of the         SkinPen® Precision and *discard appropriately. How to charge:    • Inductive charging is used between the SkinPen® Precision         charger base and the SkinPen® Precision device.    • Plug the charger base into a live outlet.    • Place the hand-piece into the base with the power         button facing out. See “FAQ/Troubleshooting” for         additional battery information.  Battery charge         percentages in “FAQ/Troubleshooting”.Power:    • ON: Press and hold power button for 2 seconds.    • OFF: Press and hold power button for 2 seconds.8. PROCEDURE INSTRUCTIONS,  POST-PROCEDURE INSTRUCTIONS,  POST-PROCEDURE CARE•  For Procedure, Post-Procedure instructions, and Post-Procedure      Care refer to SkinPen® IFU Rev.V1.0. 9. CLEANING OF SKINPEN PRECISION AND CHARGER BASE  *Ensure SkinPen® Precision device is powered down before cleaning,        and SkinPen® Precision charger base is unplugged.• Sani-Cloth® wipes may be used to clean SkinPen® Precision after    each procedure. Sani-Cloth® wipes may also be used to clean the   SkinPen® Precision Charger Base. •  Do not immerse in liquids.•  Do not use solvents to clean device. 10. STORAGE•  For optimal performance of you SkinPen® Precision, ensure the    device is turned off and store the device in the SkinPen® Precision    charging base when not in use.   Clear Faults3217    SkinPen® Precision Rev.V1.0
11. DISPOSAL•  Dispose of cartridges/needle tips as medical waste via    a Sharps container.•  Properly dispose of all items in accordance with local regulations.•  You must dispose of SkinPen® Precision, SkinPen® Precision Charger,    and all other SkinPen® Precision components properly according to    local laws and regulations. Because SkinPen® Precision contains    electronic components and a battery, SkinPen® Precision must be    disposed of separately from household waste. When SkinPen®    Precision reaches its end of life, contact local authorities to learn    bout disposal and recycling options. 12. WARRANTY •  One year under normal use after its original purchase.•  Warranty extends only to the original purchaser and purchase date.•  Contact Bellus Medical, LLC Customer Service at 1.888.372.3982    for warranty inquiries.•  Warranty does not cover:    • Defects due to negligence, alteration, modification,         or installation by anyone other than factory         authorized personnel.    • Abuse or misuse.    • Attempted or actual dismantling, disassembling, service,         or repair not specifically authorized by Bellus Medical, LLC. 13. FAQ/TROUBLESHOOTINGFault Indications:  • Motor Speed Fault:         LED 1, 3 alternating  at 0.25 sec. rate.  ›Devicewillturnoffandfaultisindicatedby           beeping for 10 sec.  • Over Current Fault:         LED 3 flashing at 0.25 sec. rate.  ›Devicewillturnoffandfaultisindicatedby           beeping for 10 sec.  • Over Temperature Fault:         LED 2 flashing at 0.25 sec. rate.  Temperatureisover65°C.  ›Devicewillturnoffandfaultisindicatedby           beeping for 10 sec.Over Current FaultOver Temperature Fault321321Motor Speed FaultSkinPen® Precision Rev.V1.0    8Over Temperature FaultMotor Position Fault321
  • Motor Position Fault:         LED 1, 2 alternating at 0.25 sec. rate.  ›Ifdeviceisunabletostopatthehomeposition           then fault is indicated by beeping for 10 sec.Battery percentage indications in running state:    • Battery Charged > 70%:        LED 1, 2, 3 ON.  •30%<BatteryCharge≤70%:        LED 1, 2 ON.  •15%<BatteryCharge≤30%:          LED 1 ON.  •1%<BatteryCharge≤15%:        LED 1 flash on/off 1 sec. rate.    • If the battery charge is <1% and the user attempts to         power on the device, LED1 will flash at 0.5 second rate         for 10 seconds and return to off mode.Battery Charge Indicator in Charging state:    • Battery Charge > 90%:        LED 1, 2, 3 ON.  •70%<BatteryCharge≤90%:        LED 1, 2 ON, LED 3 repeat on/off 1 sec.  •30%<BatteryCharge≤70%:        LED 1 ON, LED 2 repeat on/off 1 sec.  •BatteryCharge≤30%:        LED 1 repeat on/off 1 sec.   70% < Battery Charge32130% < Battery Charge3213213213213213219    SkinPen® Precision Rev.V1.0Over Temperature FaultMotor Position Fault Clear Faults321321321
14. SPECIFICATIONS Technical Information of SkinPen® PrecisionProduct Name     SkinPen® PrecisionSkinPen® Precision Model Number   100SkinPen® Charger Base Model Number  101Bellus Medical FDA Registration #   # 3010392991Weight and Unit        5oz / 155mm length and       max. outer diameter of 34mmElectrical Requirements       Input voltage: 4.2VOutput voltage:         5V battery Charger Time         From 10% charge to 90%       charge within 12 hoursWorking Time         > 6 hours       (under normal use conditions)Speed      6300RPM – 7700RPMNeedles         14 pin, 32g, Stainless SteelOperation     CordlessAC Adapter         Medical Grade, 5VDC +/- 5%,       1A minimum, 59” length 15. ENVIRONMENTAL CONDITIONSOperatingconditions:   Temperature:15-30°C     Relative humidity: 30-75%       relative humidity non-condensing Transportationconditions:  Temperature:-20-60°C     Relative humidity: 10-98%       relative humidity non-condensing This user manual is valid for SkinPen® Precision, the SkinPen® Precision  Charger Base (with AC adapter), SkinPen® Precision BioSheath and  SkinPen® Treatment Kit.Refer to the SkinPen® Precision Instructions For Use for additional  information on the Procedure Instructions.This user manual is published by Bellus Medical, LLC. Bellus Medical, LLC. Does not guarantee its contents and reserves the right to improve and amend it at any time without prior notice. Amendments will however be  published in a new edition of this manual.SkinPen® Precision Rev.V1.0    10
 SkinPen® Precision Rev.V1.0Declaration of ConformityBellus Medical, LLC. Declares that the SkinPen® Precision and  SkinPen® Precision charger base complies with the following  normative documents: IEC 62133, IEC 60601-1, IEC60601-1-2, IEC 60601-1, IEC 62366,  ISO 14971:2012, IEC 62304, ISO:13485:2003, MDD 93/42/EEC, RoHS, ISO15223:2012, IEC 60601-1-6, IEC 60529, IEC 62304, ISO 10993-1,  ISTA-2A, IEC 62133, UN 38.3This device complies with Part 15 of the FCC Rules. Operation is subject  to the following two conditions: (1) this device may not cause harmful  interference, and (2) this device must accept any interference received,  including interference that may cause undesired operation.12001 North Central ExpresswaySuite 250Dallas, TX 752431.888.372.3982info@bellusmedical.comwww.skinpen.comwww.bellusmedical.comSkinPen® Precision Rev.V1.0

Navigation menu