BIOTRONIC TECHNOLOGY 48525332323030 WIRELESS HEART RATE TRANSMITTER User Manual

Taiwan Biotronic Technology Inc. WIRELESS HEART RATE TRANSMITTER Users Manual

Users Manual

Download: BIOTRONIC TECHNOLOGY 48525332323030 WIRELESS HEART RATE TRANSMITTER User Manual
Mirror Download [FCC.gov]BIOTRONIC TECHNOLOGY 48525332323030 WIRELESS HEART RATE TRANSMITTER User Manual
Document ID2060002
Application IDNHNpjHRCmkVnGvqhn/a7uw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize19kB (237481 bits)
Date Submitted2013-09-03 00:00:00
Date Available2013-09-03 00:00:00
Creation Date2013-08-27 13:05:37
Producing SoftwareAcrobat Distiller 11.0 (Windows)
Document Lastmod2013-08-27 13:06:02
Document TitleUsers Manual
Document CreatorPScript5.dll Version 5.2.2
Document Author: User

3. Adjust the strap length to fit around your chest
snugly and comfortably, just below the pectoral
muscles.
4. Check that the wet electrode areas are
firmly against your skin and that the logo
of the Transmitter is in a central, upright
position.
LifeVisa WIRELESS HEART RATE TRANSMITTER
HRS‐2200 User Manual
2.4GHz
Thank you for purchasing LifeVisa products. This manual contains
information required to use the Heart Rate Transmitter. Please read this
manual thoroughly before you use the Heart Rate Transmitter.
COMPONENTS
Heart Rate Transmitter
TROUBLESHOOTING AND CARE
Troubleshooting of the Transmitter
Elastic Strap
O-Ring
● If you are not getting a good connection to the host, please
(a) Check the Transmitter and make sure it's not worn too high or too low
on the chest. Adjust the position of the Transmitter on the chest to
see if satisfactory connection has been achieved.
(b) Apply some ECG gel on the electrodes to get better performance.
(c) Check if the battery is installed properly or change a new battery.
(d) Repeat HOST CONNECTION section.
Battery Cover
Magnetic Key
● The Transmitter will not detect heart rate when operated under water.
● The effective range of the whole system is 10 meters. If the host is
away by a greater distance than this, it might not receive a heart rate
signal.
Screw x 4pcs
3V CR2032
Lithium Battery
TRANSMITTER BATTERY INSTALLMENT
Care of the Heart Rate Transmitter
● After every use, you should clean the electrodes in warm fresh water
and dry with a dry cloth.
● DO NOT store the Transmitter wet; it must be stored in a cool and dry
place, and kept out of extremely cold and hot.
● The Transmitter should be stored flat rather than folded and should
never be bent or stretched, as this may damage the electrodes.
● Never lay the Transmitter on a metal surface or near magnet.
● Avoid the Transmitter from direct exposure to sunlight.
● Electrodes and gel should never be applied over broken skin.
● Trim (don't shave) your body hair where electrodes are going to be put.
● Clean skin before and after wearing the Transmitter.
This Transmitter includes a 3V CR2032 lithium battery.
Please follow below steps to install the battery.
Step 1.
Insert the battery (CR2032) with the positive (+) side up.
☆ Make sure the battery is hooked by the contact spring.
Step 2.
Put on the O-Ring in the groove to ensure water resistance.
☆ Make sure to place the O-Ring properly in order to prevent battery
composition from being spoiled by sweat and moisture.
Step 3.
Place Battery Cover with convex face up.
Step 4.
Tighten 4 screws properly.
3. Wait for connection.
Step 4.
Step 3.
Step 2.
4. The host should begin to display a reading, showing the connection
has been done and you can start your workouts.
Step 1.
Connection
done!!!
NOTE:
☆ Open the battery cover only when changing the battery to ensure a
long life, and make sure the O-Ring is not damaged, in which case
you should replace it with a new one.
☆ Keep battery away from children. If swallowed, contact a physician
at once. B atteries should be disposed of in compliance with applicable
laws and regulations .
NOTE:
☆ This step only has to be done at the first time of use with the same
Transmitter and host. Afterwards, even changing battery, you don't
HOST CONNECTION
need to reconnect to the host.
This Transmitter must be recognized to the host before being used for the first ☆ See TROUBLESHOOTING AND CARE section if you are experiencing
connection issues.
time. Please follow below instructions to complete the connection.
HOW TO WEAR THE TRANSMITTER
1. Turn on the host and enter connection
mode. The host will wait the signal
for 1 minute. If not receiving the
signal, the host will exist the
connection mode automatically.
The Heart Rate Transmitter consists of two conductive electrodes. The
electrodes sense the heart beat.
☆ The effective distance/range is within 10 meters. Be sure no other
ELECTRODES
devices are within this distance making the same approach.
1. For best performance, before wearing the Transmitter, please moisten
the electrodes on the back of the Transmitter using clean tap water or
ECG gel. This makes it easier for the electrodes to detect the electrical
signal.
2. Use Magnetic Key to startup the
host connection function in the
Heart Rate Transmitter by sliding
on the top of Transmitter.
2. Attach one side of the strap to the Transmitter. Then wear it over your
chest and meet the strap with the Transmitter at the other side.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:
. Reorient or relocate the receiving antenna.
. Increase the separation between the equipment and receiver.
. Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: To assure continued compliance, any changes or modifications not
expressly approved by the party responsible for compliance could void the user's
authority to operate this equipment. (Example ‐ use only shielded interface cables
when connecting to computer or peripheral devices).
FCC Radiation Exposure Statement
This transmitter must not be co‐located or operating in conjunction with any other
antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that
may cause undesired operation.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : User
Create Date                     : 2013:08:27 13:05:37+08:00
Modify Date                     : 2013:08:27 13:06:02+08:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2013:08:27 13:06:02+08:00
Format                          : application/pdf
Title                           : <4852532D32323030AD5EA4E5BBA1A9FAAED12E786C73>
Creator                         : User
Producer                        : Acrobat Distiller 11.0 (Windows)
Document ID                     : uuid:77f1b6b6-d48c-414d-baa6-ce4649b98a13
Instance ID                     : uuid:3eaa8772-6678-4240-9697-c7bb5cfabffd
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AAQQ48525332323030

Navigation menu