BIOTRONIK SE and KG CM08V-1 Patient Device User Manual 362453 D GA CM II S TLine US indd
BIOTRONIK SE & Co. KG Patient Device 362453 D GA CM II S TLine US indd
Contents
- 1. Manual1
- 2. Manual2
Manual1
CardioMessenger ®II-S TLine Transmitter for BIOTRONIK Home Monitoring® 362453_D_GA_CM_II-S_TLine_US.ind1 1 Technical Manual 17.04.08 16:29:59 © by BIOTRONIK GmbH & Co. KG All rights reserved. Specifications subject to modification, revision and improvement. 2008-D-05 ® CardioMessenger is a registered trademark of BIOTRONIK GmbH & Co. KG BIOTRONIK GmbH & Co. KG Woermannkehre 1 12359 Berlin · Germany Tel +49 (0) 30 68905-0 Fax +49 (0) 30 6852804 BIOTRONIK, Inc. 6024 SW Jean rd. Bldg. B Lake Oswego, OR 97035 Phone (800) 547-0394 (24-hr) Fax (503) 635-9936 sales@biotronik.com www.biotronik.com 362453_D_GA_CM_II-S_TLine_US.ind2 2 17.04.08 16:30:00 Call back light (yellow, page 22) Operating light (yellow/green, page 21) Slot for the brief instructions guide (page 20) Use only original power supply units (page 16) Connections for the landline (page 9 - 14) Connection for the power supply (page 16) 362453_D_GA_CM_II-S_TLine_innen_1 1 05.05.08 15:00:47 CM _II-S_TLine.book Page 1 Tuesday,M ay 6,2008 12:56 PM Content Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Operate . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 How Home Monitoring works. . . . . . . . . . . 3 Check lights . . . . . . . . . . . . . . . . . . . . . . . 21 Check the completeness of the delivery . . . 5 Call back function . . . . . . . . . . . . . . . . . . . 22 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Switching Off the System. . . . . . . . . . . . . 23 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Debugging . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Connection to the landline . . . . . . . . . . . . . 8 Cleaning, maintenance, and disposal . . . . 28 Connection to the power supply. . . . . . . . 16 Precautionary measures . . . . . . . . . . . . . . 30 Self-test . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Insert brief instructions guide . . . . . . . . . 20 Technical data . . . . . . . . . . . . . . . . . . . . . . . 37 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 CardioMessenger II-S TLine 362453--D CM _II-S_TLine.book Page 2 Tuesday,M ay 6,2008 12:56 PM CM _II-S_TLine.book Page 3 Tuesday,M ay 6,2008 12:56 PM Introduction Dear patient: How Home Monitoring works You have received a pacemaker or implantable cardioverter-defibrillator (ICD) with the additional Home Monitoring function by BIOTRONIK.With Home Monitoring, the state of your heart's health and your implant are surveyed on a daily basis while you are at home. Your physician can catch up at regular intervals on how your heart is doing. Your implant is equipped with a special transmitter (1). Usually at night, the transmitter sends daily information on your heart to the patient device, your CardioMessenger (2). The transmission power from your implant is low and does not impair your health in any way. Its limited transmission range, however, requires the use of the CardioMessenger. The CardioMessenger collects the information received from the implant and automatically transmits it to the CardioMessenger II-S TLine Introduction CM _II-S_TLine.book Page 4 Tuesday,M ay 6,2008 12:56 PM BIOTRONIK Service Center (4) as encoded messages via a landline connection (3). Here, the messages are decoded and made available for viewing by your physician (5) on a protected web site. Based on the information received, your physician can decide if your implant is best configured, or if the therapy needs adjustments. In this way, Home Monitoring serves as a practical diagnostic aid to your physician. Introduction CM _II-S_TLine.book Page 5 Tuesday,M ay 6,2008 12:56 PM Check the completeness of the delivery Check all components for visible damage before using them. Use only components which are undamaged. The delivery includes the following: Telephone cable CardioMessenger II-S TLine Technical manual with brief instructions guide Power supply unit with electricity cable and DC plug CardioMessenger II-S TLine Warning! Use the CardioMessenger only if it is undamaged. Return a damaged CardioMessenger to your physician. Check the completeness of the delivery CM _II-S_TLine.book Page 6 Tuesday,M ay 6,2008 12:56 PM Warning! Use only the original parts included (for details, see "Technical data", page 37). Other equipment may impair proper functioning of the CardioMessenger and increase the emitted interference and the device's susceptibility to interference. The label on the back side of the CardioMessenger indicates the approved power supply: Check the completeness of the delivery CM _II-S_TLine.book Page 7 Tuesday,M ay 6,2008 12:56 PM Setup Place the CardioMessenger on your bedside table. The bedside table is suitable because it usually meets the following conditions: 2 The CardioMessenger is placed on a solid base and cannot fall. 2 The distance to the implant is less than 2 meters so that regular data transmission at night is assured. 2 Place the CardioMessenger in such a way that the lights can easily be viewed during the day. If the lights disturb you in your sleep, turn the CardioMessenger away from you. Do not place the CardioMessenger on the floor, next to, or under your bed. 2 Do not place the CardioMessenger next to a television set, microwave oven, or a similar source of electromagnetic interference. 2 Do not expose the CardioMessenger to temperatures exceeding 40 °C (104 °F). Do not put it on a place with direct sun light and do not place it directly under a halogen spotlight. 2 Do not expose the CardioMessenger to temperatures lower than 10°C (50°F). Please take the following into consideration: CardioMessenger II-S TLine 2 Protect the CardioMessenger against water and high humidity. Do not place it in the bathroom. Setup CM _II-S_TLine.book Page 8 Tuesday,M ay 6,2008 12:56 PM Connection Connection to the landline The CardioMessenger transmits the Home Monitoring data via landline. 2 Method B The CardioMessenger is operated with a telephone wall jack to which no other device is connected. There are two ways to connect the CardioMessenger to the landline: 2 Method A CardioMessenger and telephone are operated using the same telephone wall jack. In both cases, you can use your phone as usual. Note The CardioMessenger has been designed for use with an analog landline. Correct operation cannot be ensured if using a digital landline. If you are unsure what kind of landline you are using, please contact your telephone provider. Connection CM _II-S_TLine.book Page 9 Tuesday,M ay 6,2008 12:56 PM Method A To operate both the CardioMessenger and the telephone using one telephone jack To operate CardioMessenger and telephone together in one telephone wall jack, proceed as follows: 1. On the back side of the CardioMessenger: Remove the sealing plug from phone inlet 1. Phone inlet 1 is labeled with the following symbol: 2. Unplug the telephone cable from the telephone wall jack. CardioMessenger II-S TLine Connection CM _II-S_TLine.book Page 10 Tuesday,M ay 6,2008 12:56 PM 3. Connect the free end of the telephone cable to phone inlet 1 of the CardioMessenger. The telephone is now connected to the CardioMessenger. 10 Connection 4. Remove the sealing plug from phone inlet 2. Phone inlet 2 is labeled with the following symbol: CM _II-S_TLine.book Page 11 Tuesday,M ay 6,2008 12:56 PM 5. Take the supplied telephone cable and connect one end to phone inlet 2. 6. Connect the other end of the supplied telephone cable to the telephone wall jack. 7. Check the telephone connection. Lift and listen to the receiver. The usual dialing tone should be audible. CardioMessenger II-S TLine Connection 11 CM _II-S_TLine.book Page 12 Tuesday,M ay 6,2008 12:56 PM The telephone and CardioMessenger are now connected to the landline. As a next step, connect the CardioMessenger to the power supply (see "Connection to the power supply", page 16). 12 Connection CM _II-S_TLine.book Page 13 Tuesday,M ay 6,2008 12:56 PM Method B Operate the CardioMessenger using an available wall jack. To operate the CardioMessenger in a telephone wall jack to which no other devices are connected, proceed as follows: 1. On the back side of the CardioMessenger: Remove the sealing plug from phone inlet 1. Phone inlet 1 is labeled with the following symbol: CardioMessenger II-S TLine Connection 13 CM _II-S_TLine.book Page 14 Tuesday,M ay 6,2008 12:56 PM 2. Take the supplied telephone cable and connect one end to phone inlet 1. 14 Connection 3. Connect the other end of the supplied telephone cable to the telephone wall jack. CM _II-S_TLine.book Page 15 Tuesday,M ay 6,2008 12:56 PM The CardioMessenger is now connected to the landline. As a next step, connect the CardioMessenger to the power supply (see "Connection to the power supply", page 16). CardioMessenger II-S TLine Connection 15 CM _II-S_TLine.book Page 16 Tuesday,M ay 6,2008 12:56 PM Connection to the power supply Connect the CardioMessenger to the power supply. The outlet to be used has to be easily accessible. Use the supplied power supply unit with electricity cable and DC plug. Warning! Use only the original parts included (for details, see "Technical data", page 37). Other equipment may impair proper functioning of the CardioMessenger and increase the emitted interference and the device's susceptibility to interference. The label on the back side of the CardioMessenger indicates the approved power supply: 16 Connection 1. Connect the DC plug at the end of the electricity cable to the port on the left side of the CardioMessenger. The connector port is labeled with the following symbol: CM _II-S_TLine.book Page 17 Tuesday,M ay 6,2008 12:56 PM 2. Connect the power supply unit to the outlet. See that the outlet is not controlled by a light switch. This will prevent you from turning off the CardioMessenger accidentally. CardioMessenger II-S TLine Connection 17 CM _II-S_TLine.book Page 18 Tuesday,M ay 6,2008 12:56 PM Self-test The CardioMessenger automatically conducts a self-test after being connected. At first, both lamps on the front side of the CardioMessenger illuminate yellow for a short while. The connection check can take up to 15 minutes. As soon as the connection has been checked successfully, the operating light illuminates green. The CardioMessenger is now ready for use. After about 10 seconds, the call back light will turn off. Then the CardioMessenger checks the connection to the BIOTRONIK Service Center. Only the operating light illuminates yellow. 18 Connection The CardioMessenger is intended for continuous operation. It should be connected at all times, especially at night. Note It is a sign of malfunction if the operating light remains illuminated yellow for more than 15 minutes or if it does not light up at all. For details on the subject of "Debugging", see page 24. CM _II-S_TLine.book Page 19 Tuesday,M ay 6,2008 12:56 PM If you are operating CardioMessenger and telephone using one telephone wall jack (variant A), the readily connected CardioMessenger looks as follows: CardioMessenger II-S TLine If you are operating the CardioMessenger on a free telephone wall jack (variant B), the readily connected CardioMessenger looks as follows: Connection 19 CM _II-S_TLine.book Page 20 Tuesday,M ay 6,2008 12:56 PM Insert brief instructions guide Attached to the back cover of this technical manual is a removable instructions guide. 3. Insert the brief instructions guide into the slot on the left side into the housing of the CardioMessenger. This guide helps to inform you quickly about the function and colors of the lights. Additionally, you can list your physician's phone number at the back cover of this guide. 1. Remove the guide from this technical manual. 2. Write your physician's or the clinic's name and phone number on the back cover of this guide. Now the brief instructions guide with your physician's phone number are ready at hand. Use it if the call back function of the CardioMessenger was activated by your physician. For details on the subject of "Call back function", see page 22. 20 Connection CM _II-S_TLine.book Page 21 Tuesday,M ay 6,2008 12:56 PM Operate The CardioMessenger does not have an on/off switch. After connecting it, it is ready for use as soon as the operating light illuminates green. It is intended for continuous operation and should remain connected at all times, especially at night. The CardioMessenger automatically receives the information from your implant and transmits it to the BIOTRONIK Service Center. Note It indicates a malfunction if the operating light illuminates yellow or does not light up at all. For details on the subject of "Debugging", see page 24. CardioMessenger II-S TLine Check lights Check once a day whether either of the two lights is illuminated. Usually the operating light illuminates green. The call back light is not illuminated. Note The functions of your implant are not affected at any time by the CardioMessenger, irrespective of the illumination or blinking of the lights. See the next page for details on the subject "call back function". Operate 21 CM _II-S_TLine.book Page 22 Tuesday,M ay 6,2008 12:56 PM Call back function Perform call back With the aid of the call back light, your physician can ask you to call him. He can turn this light on via the landline. The light will then blink yellow for a maximum time of 3 days. Call your physician as soon as you realize that the call back light is blinking. The call back light blinks if your physician expects your call. Your physician will let you know whether he or she intends to use this function in general. 22 Operate Note The brief instructions guide with your physician's phone number is located in the housing of the CardioMessenger (see "Insert brief instructions guide", page 20). CM _II-S_TLine.book Page 23 Tuesday,M ay 6,2008 12:56 PM Turn off the call back light Switching Off the System To turn off the call back light, disconnect the CardioMessenger briefly from the main supply. The CardioMessenger does not have an on/off switch. To turn off the CardioMessenger, disconnect it from the main supply. 1. Pull the DC plug at the end of the electricity cable out of the port on the left side of the CardioMessenger. Both lights will turn off. 2. Connect the DC plug to the port again. 1. Remove the power plug from the wall outlet. The operating control lamp will turn out. The CardioMessenger is switched off. The CardioMessenger performs the self-test. Afterwards, the operating light will illuminate green and the call back light will no longer be blinking. Note For details on the subject of "Connection to the power supply", see page 16. CardioMessenger II-S TLine Operate 23 CM _II-S_TLine.book Page 24 Tuesday,M ay 6,2008 12:56 PM Debugging You can identify issues with your CardioMessenger by use of the lights on the front side. Light Behavior Operating status Call back light Off Normal operation; no malfunction Yellow blinking Your attending physician is asking for a call (For details on the subject of "Call back function", see page 22.); no malfunction Yellow blinking Error type B (both lights blink yellow): Repeat the selftest, see next page for further details Off Error type A: Check the power supply, see next page Green illumination The CardioMessenger is ready for use; no malfunction Yellow blinking Error type B (both lights blink yellow): Repeat the selftest, see next page for further details Yellow illumination Error type C (only this light illuminates): Check the landline connection, see next page for further details Operating light 24 Debugging CM _II-S_TLine.book Page 25 Tuesday,M ay 6,2008 12:56 PM Error type A: Check the power supply Error type B Repeat the self-test The operating light is off. CardioMessenger is not ready for use. Both lights blink yellow. The CardioMessenger has not concluded the self-test. It is not yet ready for use. Check the power supply: 2 Make sure that the DC plug of the electrical cord is plugged in tightly into the port on the left side of the CardioMessenger. 2 Make sure that the power supply unit is inserted properly into the wall outlet. 2 Make sure that the outlet has current, for example by temporarily connecting the bedside lamp to the outlet and by turning the lamp on. If you do not find any errors, contact your physician. CardioMessenger II-S TLine 1. Remove the power supply unit from the wall outlet. 2. Reconnect it. The CardioMessenger restarts and performs the self-test. Both lights will illuminate yellow. The call back light will turn off once the selftest is complete. The operating light will remain illuminated yellow. Next, the CardioMessenger checks the connection to the BIOTRONIK Service Center. The operating light switches to green once the connection test is sucessful. The CardioMessenger is now ready for use. Debugging 25 CM _II-S_TLine.book Page 26 Tuesday,M ay 6,2008 12:56 PM If both lights stay permanently illuminated yellow, the CardioMessenger is defective. Return it to your physician. Note The connection check can take up to 15 minutes. Error type C Check the landline connection The operating light illuminates yellow continuously (longer than 15 minutes). The call back light is off. CardioMessenger cannot connect to the BIOTRONIK Service Center. 1. Make sure that the one end of the telephone cable is properly inserted into the telephone wall jack. 2. Make sure that the other end of the telephone cable is properly inserted into phone inlet 1 on the back of the CardioMessenger. 3. Check whether the telephone line is available by lifting and listening to the receiver. You should be able to hear the normal dial tone. 4. Remove the power supply unit from the wall outlet. 5. Reconnect it. 26 Debugging CM _II-S_TLine.book Page 27 Tuesday,M ay 6,2008 12:56 PM The CardioMessenger restarts and performs the self-test. It checks the connection to the BIOTRONIK Service Center. The operating light switches to green once the connection test is sucessful. The CardioMessenger is now ready for use. Note The connection check can take up to 15 minutes. Note The CardioMessenger has been designed for use with an analog landline. Correct operation cannot be ensured if using a digital landline. If you are unsure what kind of landline you are using, please contact your telephone provider. If the operating light remains continuously illuminated yellow, contact your physician. CardioMessenger II-S TLine Debugging 27 CM _II-S_TLine.book Page 28 Tuesday,M ay 6,2008 12:56 PM Cleaning, maintenance, and disposal Cleaning Maintenance 2 Keep the CardioMessenger clean and away from dirty or dusty environments. The CardioMessenger is intended for continuous, automatic operation. Once correctly installed, ongoing actions by you are typically not required (e.g., no maintenance is required). 2 Use a soft, lint-free cloth for cleaning. Caution! Disconnect the CardioMessenger from the main power supply before attempting to clean it with a moist cloth. 2 Use a cloth wetted with water for cleaning. However, avoid bringing the CardioMessenger into direct contact with water or solvents. 28 Cleaning, maintenance, and disposal In continuous operation, the longevity of the contained button cell corresponds to the longevity of the CardioMessenger. CM _II-S_TLine.book Page 29 Tuesday,M ay 6,2008 12:56 PM Disposal Do not dispose the CardioMessenger in the usual household trash. CardioMessenger and the power supply unit contain materials that must be correctly disposed of in accordance with environmental protection regulations. If no longer required or if defective, please return the CardioMessenger and all other supplied parts to the physician. Your physician will return all parts to BIOTRONIK. BIOTRONIK ensures the disposal in accordance with the national design of the European guideline 2002/96/EC on electric and electronic used devices (WEE). CardioMessenger II-S TLine Cleaning, maintenance, and disposal 29 CM _II-S_TLine.book Page 30 Tuesday,M ay 6,2008 12:56 PM Precautionary measures The CardioMessenger is a medical device and therefore complies with strict requirements for their development, manufacture and testing. Please take the following precautions: Warning! The device must be located outside the patient's vicinity if the intended user is to be introduced to the device in the hospital. Other equipment may impair proper functioning of the CardioMessenger and increase the emitted interference and the device's susceptibility to interference. The label on the back side of the CardioMessenger indicates the approved power supply: These legal requirements apply for electrical devices in hospitals and do not apply when the CardioMessenger is used at home. Warning! Use the CardioMessenger only if it is undamaged. Return a damaged CardioMessenger to your physician. Warning! Use only the original parts included (for details, see "Technical data", page 37). 30 Precautionary measures Caution! Federal (U.S.A.) law restricts this device to sale by, or on the order of, a physician (or properly licensed practitioner). CM _II-S_TLine.book Page 31 Tuesday,M ay 6,2008 12:56 PM Caution! Protect the CardioMessenger from: – Water and high humidity – Temperatures above 40 °C (104 °F) (for example from direct sunlight and strong halogen spotlights) – Temperatures below 10 °C (50 °F) – Solvents, acids, detergents, and lyes Caution! The CardioMessenger may only be opened and repaired by authorized trained personnel. CardioMessenger II-S TLine Precautionary measures 31 CM _II-S_TLine.book Page 32 Tuesday,M ay 6,2008 12:56 PM 32 Precautionary measures CM _II-S_TLine.book Page 33 Tuesday,M ay 6,2008 12:56 PM Guidelines USA FCC RF Exposure Requirements Your implant is equipped with a radio frequency (RF) transceiver for wireless communications to the CardioMessenger. These messages are transmitted via an RF assigned by the Federal Communications Commission's (FCC) Medical Implant Communications Service (MICS)1). This device may not interfere with stations operating in the 400.150–406.000 MHz band in the Meteorological Aids, Meteorological Satellite, and Earth Exploration Satellite Services and must accept any interference received, including interference that may cause undesired operation. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This transceiver shall be used only in accordance with the FCC rules governing the Medical Implant Communications Service. Analog and digital voice communications are prohibited. Although this transceiver has been approved by the Federal Communications Commission, there is no guarantee that it will not receive interference or that any particular transmission from this transceiver will be free from interference. 1) Federal Communications Commission for Medical Implant Communications Service CardioMessenger II-S TLine Guidelines 33 CM _II-S_TLine.book Page 34 Tuesday,M ay 6,2008 12:56 PM The FCC ID number for the CardioMessenger is QRICM08V-1. The ACTA ID number for the cable modem is AU7MMO1BMT5656SMI for the CardioMessenger II-S/1 and AU7MDO4B2456 for the CardioMessenger II-S/2. Statement according to FCC part 2.1091: The internal/external antennas used for this mobile transmitter must provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Statement according to FCC part 15.105: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used 34 Guidelines in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/ TV technician for help. Changes or modifications not expressly approved by this company could void the user's authority to operate the equipment. CM _II-S_TLine.book Page 35 Tuesday,M ay 6,2008 12:56 PM Adress of responsible party: BIOTRONIK, Inc. 6024 SW Jean rd. Bldg. B Lake Oswego, OR 97035 Phone (800) 547-0394 Canada The CardioMessenger is registered at Industry Canada with the following number: IC: 4708ACM08V1. The cable modem is registered at Industry Canada with the following number: IC: 125A0015 or 125A-0008. The term "IC:" before the certification/ registration number only signifies that the Industry Canada technical specifications were met. This device may not interfere with stations operating in the 400.150-406.000 MHz band in the meteorological aids, meteorologicalsatellite, and earth exploration-satellite services and must accept any interference received, including interference that may cause undesired operation. CardioMessenger II-S TLine Guidelines 35 CM _II-S_TLine.book Page 36 Tuesday,M ay 6,2008 12:56 PM Electromagnetic compatibility Warranty Note The CardioMessenger is protected from disturbances resulting from electromagnetic interference, electrostatic discharges, and other sources – including interference induced by cables. Interfering emissions from the CardioMessenger have been minimized. The CardioMessenger therefore meets the requirements of EN 60601-1-2 in every respect. The CardioMessenger and all original components by BIOTRONIK are not subject to warranty when used improperly or stored and transported incorrectly. Use only the original packaging when shipping the device. Warning! Other equipment, including portable and mobile RF radiocommunications equipment may interfere with the CardioMessenger, even if this equipment complies with CISPR emission requirements. However, this possible interference does not affect the implant functionality. 36 Guidelines CM _II-S_TLine.book Page 37 Tuesday,M ay 6,2008 12:56 PM Technical data General CardioMessenger 2 Operating mode: Continuous operation 2 Dimensions (WxHxD): approx. 203 x 136.5 x 80 mm Permissible Environmental Conditions 2 MICS: Modulation FSK 2 Operating temperature: +10°C (50°F) to +40 C (104°F) 2 MICS frequencies: 402–405 MHz, 9 channels, 300 kHz frequency range 2 Storage and transport temperature: -10°C (14°F) to + 60°C (140°F) 2 MICS transmission power: 25 µW EIRP 2 Relative humidity: 30% to 75% (non-condensing) Telephone cable 2 Atmospheric pressure: 700 hPa to 1060 hPa 2 Type: VK-117 2 Length: approx. 2.5 m (8.2 ft) 2 Outlet: Rj-11 CardioMessenger II-S TLine Technical data 37 CM _II-S_TLine.book Page 38 Tuesday,M ay 6,2008 12:56 PM Power supply unit or: 2 Type: FRIWO MMP 15 FW7555O/05 2 Type: Nordic Power (SAC) SA110D-05 2 Dimensions (WxHxD): approx. 51.5 x 87.5 x 34 mm 2 Dimensions (WxHxD): approx. 69 x 45 x 35 mm 2 DC plug output: Outer diameter 5.5 mm (mass), Inner diameter 2.1 mm (plus) 2 DC plug output: Outer diameter 5.5 mm (mass), Inner diameter 2.1 mm (plus) 2 Input voltage: 100–240 V ~ 50–60 Hz 400 mA 2 Input voltage: 100–240 V ~ 50–60 Hz 300 mA 2 Output voltage: 5 V DC ± 5 %, 2.4 A/12 W 2 Output voltage: 5.1 V DC ± 5 %, 2 A/10.2 W 2 Safety class: II 2 Safety class: II Technical manual 2 Technical manual with brief instructions guide CardioMessenger II-S TLine 38 Technical data CM _II-S_TLine.book Page 39 Tuesday,M ay 6,2008 12:56 PM Appendix Electromagnetic emitted interference according to IEC 60601-1-2 The CardioMessenger is suitable for operation in the indicated electromagnetic environment. The customer and/or operator of the CardioMessenger should make sure that it is used in an electromagnetic environment as described below. Measuring the interference Compliance Guidelines for the electromagnetic environment High-frequency interference according to CISPR 11 Group 1 The CardioMessenger uses RF energy only for its internal function. Therefore, the HF interference is very low and not likely to cause any interference in nearby electronic equipment. High-frequency interference according to CISPR 11 Class B Interference of harmonics according to IEC 61000-3-2 Class A according to IEC 61000-3-2 The CardioMessenger is suitable for use in all areas, including living space and those areas that are directly connected to a public power supply system that also supplies buildings intended for residential purposes. Voltage fluctuations/flicker emissions according to IEC 61000-3-3 Complies CardioMessenger II-S TLine Appendix 39 CM _II-S_TLine.book Page 40 Tuesday,M ay 6,2008 12:56 PM Electromagnetic emitted interference according to IEC 60601-1-2 The CardioMessenger is suitable for operation in the indicated electromagnetic environment. The customer and/or operator of the CardioMessenger should make sure that it is used in an electromagnetic environment as described below. Testing resistance to interference Test level according to IEC 60601-1-2 Conformance level Guidelines for the electromagnetic environment Conducted RF interference according to IEC 61000-4-6 3Veff 150 kHz to 80 MHz Same as test level The minimum distance of the CardioMessenger from portable and mobile radio devices, including the cables, should correspond to the recommended safe distance that is calculated according to the equation for the suitable transmission frequency. Recommended safe distance: D= 1,17 P Radiated RF interference according to IEC 61000-4-3 3V/m 80 MHz to 2.5 GHz Same as test level D= 1,17 P for 80 to 800 MHz D= 2,34 P for 800 MHz to 2.5 GHz with P as the nominal output of the transmitter in Watts (W) according to the information from the transmitter manufacturer, and d as the recommended safe distance in meters (m). The field strength of stationary transmitting devices should be measured on sitea) and must be lower than the compliance level at all frequenciesb). Interference can be generated when the CardioMessenger is close to devices that have the following warning sign: Note: The higher frequency range applies at 80MHz and at 800MHz. Note: These guidelines may not be applicable in all cases. The spread of electromagnetic waves is influenced by absorption and reflection from buildings, objects, and humans. 40 Appendix CM _II-S_TLine.book Page 41 Tuesday,M ay 6,2008 12:56 PM a) Field strengths from fixed transmitters, such as base stations for radio (cellular(/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the CardioMessenger is used exceeds the applicable RF compliance level above, the CardioMessenger should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the CardioMessenger. b) Above the frequency range of 150KHz to 80MHz, ensure that field strengths are less than 3V/m. CardioMessenger II-S TLine Appendix 41 CM _II-S_TLine.book Page 42 Tuesday,M ay 6,2008 12:56 PM Electromagnetic emitted interference according to IEC 60601-1-2 The CardioMessenger is suitable for operation in the indicated electromagnetic environment. The customer and/or operator of the CardioMessenger should make sure that it is used in an electromagnetic environment as described below. Checking immunity to noise Test level according to IEC 60601-1-2 Conformance level Guidelines for the electromagnetic environment Discharge of static electricity (ESD) ± 6 kV contact discharge Same as test level Floors should be made of wood or cement, or have ceramic tiles. When the floor consists of a synthetic material, the relative humidity must be at least 30%. Same as the test level The quality of the supply voltage should correspond to that in a typical business and/or hospital. Same as the test level The quality of the supply voltage should correspond to that in a typical business and/or hospital. ±8 kV air discharge According to IEC 610004-2 Rapid transient electrical disturbances/bursts ± 2 kV for power supply lines According to IEC 610004-4 ± 1 kV for input/output lines Surge ±1kV normal mode voltage According to IEC 610004-5 42 Appendix ± 2 kV common mode voltage CM _II-S_TLine.book Page 43 Tuesday,M ay 6,2008 12:56 PM Checking immunity to noise Test level according to IEC 60601-1-2 Conformance level Guidelines for the electromagnetic environment Voltage dips, brief interruptions and fluctuations in the supply voltage ‹ 5% UT for Same as the test level The quality of the supply voltage should correspond to that in a typical business and/or hospital. The CardioMessenger is powered by a battery. An interruption in the supply voltage to the power supply unit will not impair the functioning of the CardioMessenger. Same as the test level The magnetic field strength should correspond to the typical value in business and hospital environments. According to IEC 610004-11 1/2 cycle (› 95% drop) 40% UT for 5 periods (60% drop) 70% UT for 25 periods (30% drop) ‹ 5% UT for 5 s (› 95% drop) Magnetic field at the supply frequencies (50/ 60 Hz) 3A/m According to IEC 610004-8 Comment: UT is the mains alternating voltage before applying the test levels. CardioMessenger II-S TLine Appendix 43 CM _II-S_TLine.book Page 44 Tuesday,M ay 6,2008 12:56 PM Recommended separation distances between portable and mobile RF communications equipment and the CardioMessenger Transmission frequency 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz Equation D= 1,17 P D= 1,17 P D= 2,34 P Rated power of transmitter (W) Safe distance (m) Safe distance (m) Safe distance (m) 0.01 0.12 0.12 0.24 0.1 0.37 0.37 0.74 1.17 1.17 2.34 10 3.7 3.7 7.4 100 11.7 11.7 23.4 For transmitters whose maximum nominal output is not indicated in the above table, the distance can be calculated using the equation in the column, where P is the maximum nominal output of the transmitter in Watts (W) according to the transmitter’s manufacturer. Note: The higher frequency range applies at 80MHz and at 800MHz. Note: These guidelines may not be applicable in all cases. The propagation of electromagnetic values is affected by absorption and reflection by structures, objects and people. 44 Appendix CM _II-S_TLine.book Page 45 Tuesday,M ay 6,2008 12:56 PM Index Ambient conditions . . . . . . . . . . . . . . . . . . 37 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Bedside table . . . . . . . . . . . . . . . . . . . . . . . . 7 BIOTRONIK Service Center . . . . . . . . . . 4,21 Blinking . . . . . . . . . . . . . . . . . . . . . . . . 22,24 Brief instructions guide . . . . . . . . . . . . 20,22 Broken CardioMessenger . . . . . . . . . . . . . 30 Call back function . . . . . . . . . . . . . . . . . . . 22 Call back light . . . . . . . . . . . . . . . . . . . 18,22 Call your physician . . . . . . . . . . . . . . . . . . 22 Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Check the landline connection . . . 11,18,26 Check the telephone connection . . . . . . . 11 Checking the power supply . . . . . . . . . . . . 25 Clean it . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 CardioMessenger II-S TLine Connection to the landline . . . . . . . . . . 8,19 Connection to the power supply . . . . 16,19 Damaged CardioMessenger . . . . . . . . . 5,30 DC plug . . . . . . . . . . . . . . . . . . . . . . . 5,23,38 Debugging . . . . . . . . . . . . . . . . . . . . . . . . . 24 Defective CardioMessenger . . . . . . . . . . . 30 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Distance to the implant . . . . . . . . . . . . . . . 7 Electricity cable . . . . . . . . . . . . . . . . 5,16,23 Electromagnetic Compatibility . . . . . . . . 36 Electromagnetic emitted interference . . 39 Green light . . . . . . . . . . . . . . . . . . . 18,21,24 Guidelines Canada . . . . . . . . . . . . . . . . . . 35 Guidelines USA . . . . . . . . . . . . . . . . . . . . . 33 Index 45 CM _II-S_TLine.book Page 46 Tuesday,M ay 6,2008 12:56 PM Home Monitoring . . . . . . . . . . . . . . . . . . . . . 3 Hospital . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Illumination . . . . . . . . . . . . . . . . . . . . . . . . . 24 Implant . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,7 Landline connection . . . . . . . . . . . . . . . . . . . 4 Light 1 . . . . . . . . . . . . . . . . . . . . 18,21,22,24 Light 2 . . . . . . . . . . . . . . . . . . . . . . . . . . 18,24 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . 28 Operate . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Operating light . . . . . . . . . . . . . . . . 18,21,24 Original parts . . . . . . . . . . . . . . . . . . . . . 5,37 Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 46 Index Package Contents . . . . . . . . . . . . . . . . . . . . 5 Perform call back . . . . . . . . . . . . . . . . . . . 22 Phone inlet 1 . . . . . . . . . . . . . . . . . . . . . 9,13 Phone inlet 2 . . . . . . . . . . . . . . . . . . . . . . . 10 Physician call back light . . . . . . . . . . . . . . 24 Physician's phone number . . . . . . . . . 20,22 Port for power connection . . . . . . . . . . . . 16 Power connection port . . . . . . . . . . . . . . . 16 Power supply unit . . . . . . . . . . . . . . 5,16,38 Precautionary measures . . . . . . . . . . . . . . 30 Ready-for-service status . . . . . . . . . . . . . 21 Recommended separation distances . . . 44 Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Safety instructions . . . . . . . . . . . . . . . . . . . 30 Sealing plug . . . . . . . . . . . . . . . . . . . 9,10,13 Self-test . . . . . . . . . . . . . . . . . . . . . . . . 18,25 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Suitable installation location . . . . . . . . . . . 7 CM _II-S_TLine.book Page 47 Tuesday,M ay 6,2008 12:56 PM Switch off the system . . . . . . . . . . . . . . . . 23 Switching on the system . . . . . . . . . . . 21,23 Technical data . . . . . . . . . . . . . . . . . . . . . . 37 Telephone cable . . . . . . . . . . 5,10,11,14,37 Telephone wall jack . . . . . . . . 8,9,11,13,14 Transmitter of the implant . . . . . . . . . . . 3,7 Turn off the call back light . . . . . . . . . . . . 23 Unsuitable installation location . . . . . . . . . 7 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Yellow light . . . . . . . . . . . . . . . . . . . 18,22,24 CardioMessenger II-S TLine Index 47
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2008:04:17 16:29:58+02:00 GTS PDFX Version : PDF/X-1a:2003 Creator : Adobe InDesign CS2 (4.0) GTS PDFX Conformance : PDF/X-1a:2003 Modify Date : 2008:05:08 14:16:42+02:00 Producer : Adobe PDF Library 7.0 Trapped : False Creation Date : 2008:04:17 16:29:58+02:00 Mod Date : 2008:05:08 14:16:42+02:00 Metadata Date : 2008:05:08 14:16:42+02:00 Creator Tool : Adobe InDesign CS2 (4.0) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 1728 bytes, use -b option to extract) Instance ID : uuid:3625fbb8-aa0d-4ecc-9bd4-d8c5fe3b7f1d Document ID : adobe:docid:indd:3e4e5a3d-0c8a-11dd-a994-a166943ed76c Rendition Class : proof:pdf Derived From Instance ID : 6a2ded9d-0bd3-11dd-b6a8-8dfe91d2311e Derived From Document ID : adobe:docid:indd:6a2ded9a-0bd3-11dd-b6a8-8dfe91d2311e Format : application/pdf Title : 362453_D_GA_CM_II-S_TLine_US.indd Page Count : 50EXIF Metadata provided by EXIF.tools