BQT Solutions MIP9 CONTACTLESS SMARTCARD READER User Manual USERS MANUAL
BQT Solutions (Australia) Pty Ltd CONTACTLESS SMARTCARD READER USERS MANUAL
USERS MANUAL
Page 1 of 11 EMC Technologies ABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Au Telephone +61 2 9624 Facsimile +61 2 9838 Email syd@emctech www.emctech.com.au APPENDIX L OF TEST REPORT T60821_F USER MANUALS FOR THE BQT AND PAC FCC ID: Manufacturer: Test Sample: Model: Serial Number: QVL-MIP9 BQT Solutions (Australia) Pty Ltd Contactless Smart Card Reader MiP9 and 900-PAC None Date: 29th August 2006 Melbourne 57 Assembly Drive Tullamarine Vic 3043 Tel: +61 3 9335 3333 Fax: +61 3 9338 9260 Sydney Unit 3/87 Station Road Seven Hills NSW 2147 Tel: +61 2 9624 2777 Fax: +61 2 9838 4050 Brisbane 1/15 Success Street Acacia Ridge Qld 4110 Tel: +61 7 3875 2455 Fax: +61 7 3875 2466 Auckland (NZ) 47 MacKelvie Street Grey Lynn Auckland Tel: +64 9 360 0862 Fax: +64 9 360 0861 K CMY CY MY AUSTRALIA & ASIA PACIFIC Level 4, 65 Epping Road North Ryde NSW 2113 Australia Phone: +61 (0)2 8817 2800 Fax: +61 (0)2 8817 2811 AMERICA 30021 Tomas Street, Suite 300 Rancho Santa Margarita CA 92688 United States of America Phone: +1 877 278 2637 (ext 42) Fax:+1 877 278 2637 UNITED KINGDOM & EMEA Global House, 1 Ashley Avenue, Epsom Surrey KT 18 5AD United Kingdom Phone: + 44 (0)20 8823 9350 Fax: + 44 (0)20 8823 9001 CHINA Suite 1602, No.75, ShengDa Garden, 2518 LongHua Road, XuHui District, Shanghai 200232, P.R.China Tel: +86-21-5407 3638 Fax: +86-21-5407 3738 9 series_v2.8 Aug06 INSTALLATION GUIDE Version 2.8 Alternatively contact us at one of our global locations For further technical information visit our website at www.bqtsolutions.com or email techsupport@bqtsolutions.com. Information contained in this document is subject to change without notice. Read range 20 - 60mm (0.8” – 2.4”)(typically) Operating temperature -25ºC to +65ºC (-13ºF to 149ºF) Relative humidity 90% max, operating non-condensing Reader dimensions 140mm (L) x 45mm (W) x 32mm (D) (5.51” x 1.77” x 1.26”) Status LED’s Green & Red Audible tone Internal or external buzzer control Colour Two toned – Silver & Charcoal IP rating IP 67 miPASS 9 Series Mifare reader models DF900 - DESFire BT900 - Mifare miP9 - SPEK CSN9 - Card Serial Number Normal 120mA Activated 140mA Current consumption Output protocols Wiegand 26-199 bit, RS485 or custom configurations (model dependent) Power requirements 12Vdc Specifications Drilling Template For all 9 Series readers ● 20mm (0.79”) diameter hole for wire entry ● 2 x 4 mm (0.16”) diameter holes for mounting screws ● Minimum reader dimensions are 140mm x 45 mm (5.51" x 1.77") 4mm Ø 62mm 20mm Ø Wiring Schematic Reader connections DF815/BT815 (BT815D) BT815 (BT815W or WG) miP5/CSN5 (BT815W ) ➣ CM NOTE: ➣➣ Power Cable BUZ LED W0 W1 RS485A RS485B T1 T2 YELLOW ORANGE GREEN WHITE YELLOW/W GREEN/W BROWN/W BROWN/W +12Vdc 0V RED BLACK Power Supply +12Vdc 0V Controller Cable 0V BUZ LED W0 W1 Controller NOTE: If used with a shielded cable, the shield is connected to Controller 0V reference The 0V reference cable shall be included within the controller cable. The 12Vdc power cable shall NOT be included in the controller Cable. Only ONE power source is connected from the reader at any one time. RS485 - OPTIONAL USE TAMPER SWITCH AVAILABLE ON REQUEST Regulatory Information 45mm CE Mark The 9 Series has passed all relevant tests and obtained CE approval. C Tick The 9 Series has passed all relevant requirements for application of C Tick. FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 4mm Ø ➣ NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna - Increase the separation between the equipment and receiver - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected - Consult the dealer or an experienced radio/TV technician for help Designed & Manufactured in Australia Any changes or modifications not expressively approved by BQT Solutions could void the user's authority to operate this equipment. Copyright © 2006 BQT Solutions Limited. BQT Solutions and the BQT Solutions logo are registered trademarks of BQT Solutions (Australia) Pty Ltd. Mifare is a registered trademark of Philips Electronics. 9 series_v2.8.ai 15/08/2006 11:05:23 AM 9 series_v2.8.ai 15/08/2006 11:08:35 AM Introduction Thank you for purchasing a miPASS 9 Series Mifare Contactless Smart Card Reader. Available in 4 different models catering for all security requirements large or small, whether your projects are price or functionality driven. The 9 Series reader models are: DF900 - DESFire BT900- Mifare (standard) miP9 - BQT SPEK CSN9 - Card Serial Number NOTE: Power to the unit is provided from the Listed control unit or from a separately supplied UL Listed 12 Vdc power-limited, access control power source. Wiring methods shall be in accordance with the National Electrical Code, ANSI/NFPA 70. The 9 Series reader is used in security applications and interfaces into Wiegand applications. The 9 Series reader is preset with specific 'Keys'. Valid smart cards are issued with the same 'Keys'. This ensures that the system cannot be compromised. (No 'Keys" used for CSN9 model) The reader incorporates a LED and Buzzer to provide feedback to a person wishing to enter. The control of these is shared by the reader and security controller. The 9 Series reader is low-profile and can be installed in new installations or as an upgraded reader in existing proximity access control systems. Installation If the reader has the same power supply as the door latch relay, make sure that the relay is protected by a fast Schottky diode. If the relay is not protected reader operation will be affected. 1. NOTE: 2. 3. 4. 5. 6. 7. Connect the 0V wire to the Power 0V line. The 0V line of all power supplies MUST be connected to a common 0V reference point. Connect the Wiegand signal cables. Connect the Buzzer and the LED cables. Attach the 12Vdc wire last. Place the reader on the wall (Make sure the wires are not crushed) Insert and hand tighten the screws. Check that the reader is level before tightening the screws. NOTE: Excessive tightening of screws may deform the casing, resulting in a damaged unit. This will void the warranty. 8. 9. Replace the cover. Power up the reader. NOTE: The unit needs up to 15 seconds to set up before it can respond to a valid smart card. Remove the cover by holding the unit as shown and pulling the cover from the top as illustrated CM MY CY CMY If necessary, drill holes for the mounting screws in the wall or mounting box on which the reader unit will be placed. (Use the Drilling Template provided). External Use ➣ 4mm Ø 62mm Handling WALL VIEW (not to scale) 45mm ➣➣ 20mm Ø ➣ Note: Make sure that you don't drill through the cable. Once installed the 9 Series reader requires no maintenance. Troubleshooting 1. Place the controller and power supply cable through the Grommit hole. 2. Drill the holes as indicated by the arrows. Handle the 9 Series reader with care. Do not damage/drop unit before installation. The reader unit will not be waterproof if the casing is damaged. Replace the reader if the casing is damaged. Maintenance 4mm Ø Mount the reader on a suitable external single gang surface mount box. USA ONLY - BQT mounting plate adaptor is available for mounting to a US single gang box. Make sure that the wire bundle to the 9 Series reader has an IP rating of at least IP67. Use warming pads if the temperature of the reader is expected to fall below -10ºC (14ºF). If the reader doesn't respond when a valid smart card is presented, check the following. Symptom Possible Cause Check LED is not lit No power to the reader Check the power supply to the reader. LED is Orange or Buzzer sounds low Voltage to the reader is below 10V Check the power supply to the reader Reader doesn't respond Invalid card or card is faulty Check reader with another valid smart card Reader beeps but lock doesn't open Wiring to the controller may be faulty. Check the wiring to the controller NOTE: If reader beeps when a valid smart card is presented then the reader is functioning. Check your circuit diagram for the colour coding of the circuit wiring. The reader can be damaged beyond repair if the wiring is connected incorrectly. If the problem still persists then please contact your distributor for technical support and to obtain an RMA if required. Warranty The 9 Series reader comes with a 5 year warranty from the date of dispatch from BQT Solutions. The warranty is void if the instructions contained within this manual have not been adhered to. 9 series_v2.8.ai 15/08/2006 11:08:35 AM Introduction Thank you for purchasing a miPASS 9 Series Mifare Contactless Smart Card Reader. Available in 4 different models catering for all security requirements large or small, whether your projects are price or functionality driven. The 9 Series reader models are: DF900 - DESFire BT900- Mifare (standard) miP9 - BQT SPEK CSN9 - Card Serial Number NOTE: Power to the unit is provided from the Listed control unit or from a separately supplied UL Listed 12 Vdc power-limited, access control power source. Wiring methods shall be in accordance with the National Electrical Code, ANSI/NFPA 70. The 9 Series reader is used in security applications and interfaces into Wiegand applications. The 9 Series reader is preset with specific 'Keys'. Valid smart cards are issued with the same 'Keys'. This ensures that the system cannot be compromised. (No 'Keys" used for CSN9 model) The reader incorporates a LED and Buzzer to provide feedback to a person wishing to enter. The control of these is shared by the reader and security controller. The 9 Series reader is low-profile and can be installed in new installations or as an upgraded reader in existing proximity access control systems. Installation If the reader has the same power supply as the door latch relay, make sure that the relay is protected by a fast Schottky diode. If the relay is not protected reader operation will be affected. 1. NOTE: 2. 3. 4. 5. 6. 7. Connect the 0V wire to the Power 0V line. The 0V line of all power supplies MUST be connected to a common 0V reference point. Connect the Wiegand signal cables. Connect the Buzzer and the LED cables. Attach the 12Vdc wire last. Place the reader on the wall (Make sure the wires are not crushed) Insert and hand tighten the screws. Check that the reader is level before tightening the screws. NOTE: Excessive tightening of screws may deform the casing, resulting in a damaged unit. This will void the warranty. 8. 9. Replace the cover. Power up the reader. NOTE: The unit needs up to 15 seconds to set up before it can respond to a valid smart card. Remove the cover by holding the unit as shown and pulling the cover from the top as illustrated CM MY CY CMY If necessary, drill holes for the mounting screws in the wall or mounting box on which the reader unit will be placed. (Use the Drilling Template provided). External Use ➣ 4mm Ø 62mm Handling WALL VIEW (not to scale) 45mm ➣➣ 20mm Ø ➣ Note: Make sure that you don't drill through the cable. Once installed the 9 Series reader requires no maintenance. Troubleshooting 1. Place the controller and power supply cable through the Grommit hole. 2. Drill the holes as indicated by the arrows. Handle the 9 Series reader with care. Do not damage/drop unit before installation. The reader unit will not be waterproof if the casing is damaged. Replace the reader if the casing is damaged. Maintenance 4mm Ø Mount the reader on a suitable external single gang surface mount box. USA ONLY - BQT mounting plate adaptor is available for mounting to a US single gang box. Make sure that the wire bundle to the 9 Series reader has an IP rating of at least IP67. Use warming pads if the temperature of the reader is expected to fall below -10ºC (14ºF). If the reader doesn't respond when a valid smart card is presented, check the following. Symptom Possible Cause Check LED is not lit No power to the reader Check the power supply to the reader. LED is Orange or Buzzer sounds low Voltage to the reader is below 10V Check the power supply to the reader Reader doesn't respond Invalid card or card is faulty Check reader with another valid smart card Reader beeps but lock doesn't open Wiring to the controller may be faulty. Check the wiring to the controller NOTE: If reader beeps when a valid smart card is presented then the reader is functioning. Check your circuit diagram for the colour coding of the circuit wiring. The reader can be damaged beyond repair if the wiring is connected incorrectly. If the problem still persists then please contact your distributor for technical support and to obtain an RMA if required. Warranty The 9 Series reader comes with a 5 year warranty from the date of dispatch from BQT Solutions. The warranty is void if the instructions contained within this manual have not been adhered to. 9 series_v2.8.ai 15/08/2006 11:08:35 AM Introduction Thank you for purchasing a miPASS 9 Series Mifare Contactless Smart Card Reader. Available in 4 different models catering for all security requirements large or small, whether your projects are price or functionality driven. The 9 Series reader models are: DF900 - DESFire BT900- Mifare (standard) miP9 - BQT SPEK CSN9 - Card Serial Number NOTE: Power to the unit is provided from the Listed control unit or from a separately supplied UL Listed 12 Vdc power-limited, access control power source. Wiring methods shall be in accordance with the National Electrical Code, ANSI/NFPA 70. The 9 Series reader is used in security applications and interfaces into Wiegand applications. The 9 Series reader is preset with specific 'Keys'. Valid smart cards are issued with the same 'Keys'. This ensures that the system cannot be compromised. (No 'Keys" used for CSN9 model) The reader incorporates a LED and Buzzer to provide feedback to a person wishing to enter. The control of these is shared by the reader and security controller. The 9 Series reader is low-profile and can be installed in new installations or as an upgraded reader in existing proximity access control systems. Installation If the reader has the same power supply as the door latch relay, make sure that the relay is protected by a fast Schottky diode. If the relay is not protected reader operation will be affected. 1. NOTE: 2. 3. 4. 5. 6. 7. Connect the 0V wire to the Power 0V line. The 0V line of all power supplies MUST be connected to a common 0V reference point. Connect the Wiegand signal cables. Connect the Buzzer and the LED cables. Attach the 12Vdc wire last. Place the reader on the wall (Make sure the wires are not crushed) Insert and hand tighten the screws. Check that the reader is level before tightening the screws. NOTE: Excessive tightening of screws may deform the casing, resulting in a damaged unit. This will void the warranty. 8. 9. Replace the cover. Power up the reader. NOTE: The unit needs up to 15 seconds to set up before it can respond to a valid smart card. Remove the cover by holding the unit as shown and pulling the cover from the top as illustrated CM MY CY CMY If necessary, drill holes for the mounting screws in the wall or mounting box on which the reader unit will be placed. (Use the Drilling Template provided). External Use ➣ 4mm Ø 62mm Handling WALL VIEW (not to scale) 45mm ➣➣ 20mm Ø ➣ Note: Make sure that you don't drill through the cable. Once installed the 9 Series reader requires no maintenance. Troubleshooting 1. Place the controller and power supply cable through the Grommit hole. 2. Drill the holes as indicated by the arrows. Handle the 9 Series reader with care. Do not damage/drop unit before installation. The reader unit will not be waterproof if the casing is damaged. Replace the reader if the casing is damaged. Maintenance 4mm Ø Mount the reader on a suitable external single gang surface mount box. USA ONLY - BQT mounting plate adaptor is available for mounting to a US single gang box. Make sure that the wire bundle to the 9 Series reader has an IP rating of at least IP67. Use warming pads if the temperature of the reader is expected to fall below -10ºC (14ºF). If the reader doesn't respond when a valid smart card is presented, check the following. Symptom Possible Cause Check LED is not lit No power to the reader Check the power supply to the reader. LED is Orange or Buzzer sounds low Voltage to the reader is below 10V Check the power supply to the reader Reader doesn't respond Invalid card or card is faulty Check reader with another valid smart card Reader beeps but lock doesn't open Wiring to the controller may be faulty. Check the wiring to the controller NOTE: If reader beeps when a valid smart card is presented then the reader is functioning. Check your circuit diagram for the colour coding of the circuit wiring. The reader can be damaged beyond repair if the wiring is connected incorrectly. If the problem still persists then please contact your distributor for technical support and to obtain an RMA if required. Warranty The 9 Series reader comes with a 5 year warranty from the date of dispatch from BQT Solutions. The warranty is void if the instructions contained within this manual have not been adhered to. 9 series_v2.8.ai 15/08/2006 11:08:35 AM Introduction Thank you for purchasing a miPASS 9 Series Mifare Contactless Smart Card Reader. Available in 4 different models catering for all security requirements large or small, whether your projects are price or functionality driven. The 9 Series reader models are: DF900 - DESFire BT900- Mifare (standard) miP9 - BQT SPEK CSN9 - Card Serial Number NOTE: Power to the unit is provided from the Listed control unit or from a separately supplied UL Listed 12 Vdc power-limited, access control power source. Wiring methods shall be in accordance with the National Electrical Code, ANSI/NFPA 70. The 9 Series reader is used in security applications and interfaces into Wiegand applications. The 9 Series reader is preset with specific 'Keys'. Valid smart cards are issued with the same 'Keys'. This ensures that the system cannot be compromised. (No 'Keys" used for CSN9 model) The reader incorporates a LED and Buzzer to provide feedback to a person wishing to enter. The control of these is shared by the reader and security controller. The 9 Series reader is low-profile and can be installed in new installations or as an upgraded reader in existing proximity access control systems. Installation If the reader has the same power supply as the door latch relay, make sure that the relay is protected by a fast Schottky diode. If the relay is not protected reader operation will be affected. 1. NOTE: 2. 3. 4. 5. 6. 7. Connect the 0V wire to the Power 0V line. The 0V line of all power supplies MUST be connected to a common 0V reference point. Connect the Wiegand signal cables. Connect the Buzzer and the LED cables. Attach the 12Vdc wire last. Place the reader on the wall (Make sure the wires are not crushed) Insert and hand tighten the screws. Check that the reader is level before tightening the screws. NOTE: Excessive tightening of screws may deform the casing, resulting in a damaged unit. This will void the warranty. 8. 9. Replace the cover. Power up the reader. NOTE: The unit needs up to 15 seconds to set up before it can respond to a valid smart card. Remove the cover by holding the unit as shown and pulling the cover from the top as illustrated CM MY CY CMY If necessary, drill holes for the mounting screws in the wall or mounting box on which the reader unit will be placed. (Use the Drilling Template provided). External Use ➣ 4mm Ø 62mm Handling WALL VIEW (not to scale) 45mm ➣➣ 20mm Ø ➣ Note: Make sure that you don't drill through the cable. Once installed the 9 Series reader requires no maintenance. Troubleshooting 1. Place the controller and power supply cable through the Grommit hole. 2. Drill the holes as indicated by the arrows. Handle the 9 Series reader with care. Do not damage/drop unit before installation. The reader unit will not be waterproof if the casing is damaged. Replace the reader if the casing is damaged. Maintenance 4mm Ø Mount the reader on a suitable external single gang surface mount box. USA ONLY - BQT mounting plate adaptor is available for mounting to a US single gang box. Make sure that the wire bundle to the 9 Series reader has an IP rating of at least IP67. Use warming pads if the temperature of the reader is expected to fall below -10ºC (14ºF). If the reader doesn't respond when a valid smart card is presented, check the following. Symptom Possible Cause Check LED is not lit No power to the reader Check the power supply to the reader. LED is Orange or Buzzer sounds low Voltage to the reader is below 10V Check the power supply to the reader Reader doesn't respond Invalid card or card is faulty Check reader with another valid smart card Reader beeps but lock doesn't open Wiring to the controller may be faulty. Check the wiring to the controller NOTE: If reader beeps when a valid smart card is presented then the reader is functioning. Check your circuit diagram for the colour coding of the circuit wiring. The reader can be damaged beyond repair if the wiring is connected incorrectly. If the problem still persists then please contact your distributor for technical support and to obtain an RMA if required. Warranty The 9 Series reader comes with a 5 year warranty from the date of dispatch from BQT Solutions. The warranty is void if the instructions contained within this manual have not been adhered to. 9 series_v2.8 Aug06 UNITED KINGDOM & EMEA Global House, 1 Ashley Avenue, Epsom Surrey KT 18 5AD United Kingdom Phone: + 44 (0)20 8823 9350 Fax: + 44 (0)20 8823 9001 INSTALLATION GUIDE Version 2.8 CHINA Suite 1602, No.75, ShengDa Garden, 2518 LongHua Road, XuHui District, Shanghai 200232, P.R.China Tel: +86-21-5407 3638 Fax: +86-21-5407 3738 AUSTRALIA & ASIA PACIFIC Level 4, 65 Epping Road North Ryde NSW 2113 Australia Phone: +61 (0)2 8817 2800 Fax: +61 (0)2 8817 2811 AMERICA 30021 Tomas Street, Suite 300 Rancho Santa Margarita CA 92688 United States of America Phone: +1 877 278 2637 (ext 42) Fax:+1 877 278 2637 Alternatively contact us at one of our global locations For further technical information visit our website at www.bqtsolutions.com or email techsupport@bqtsolutions.com. Information contained in this document is subject to change without notice. miPASS 9 Series Mifare reader models IP rating IP 67 Colour Two toned – Silver & Charcoal Internal or external buzzer control Audible tone Green & Red Status LED’s 140mm (L) x 45mm (W) x 32mm (D) (5.51” x 1.77” x 1.26”) Reader dimensions 90% max, operating non-condensing Relative humidity -25ºC to +65ºC (-13ºF to 149ºF) Operating temperature Read range 20 - 60mm (0.8” – 2.4”)(typically) Activated Normal CMY CY MY DF900 - DESFire BT900 - Mifare miP9 - SPEK CSN9 - Card Serial Number 140mA 120mA Current consumption Power requirements Output protocols 12Vdc Wiegand 26-199 bit, RS485 or custom configurations (model dependent) Specifications CM ➣ BT815 (BT815W or WG) miP5/CSN5 (BT815W ) Reader connections DF815/BT815 (BT815D) 62mm 20mm Ø 4mm Ø NOTE: ➣➣ For all 9 Series readers ● 20mm (0.79”) diameter hole for wire entry ● 2 x 4 mm (0.16”) diameter holes for mounting screws ● Minimum reader dimensions are 140mm x 45 mm (5.51" x 1.77") Wiring Schematic Power Cable RED BLACK YELLOW ORANGE GREEN WHITE YELLOW/W GREEN/W BROWN/W BROWN/W +12Vdc 0V BUZ LED W0 W1 RS485A RS485B T1 T2 Power Supply +12Vdc 0V 0V BUZ LED W0 W1 Controller Cable Controller NOTE: If used with a shielded cable, the shield is connected to Controller 0V reference The 0V reference cable shall be included within the controller cable. The 12Vdc power cable shall NOT be included in the controller Cable. Only ONE power source is connected from the reader at any one time. RS485 - OPTIONAL USE TAMPER SWITCH AVAILABLE ON REQUEST 45mm Regulatory Information CE Mark The 9 Series has passed all relevant tests and obtained CE approval. C Tick The 9 Series has passed all relevant requirements for application of C Tick. 4mm Ø ➣ FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna - Increase the separation between the equipment and receiver - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected - Consult the dealer or an experienced radio/TV technician for help Designed & Manufactured in Australia Any changes or modifications not expressively approved by BQT Solutions could void the user's authority to operate this equipment. Copyright © 2006 BQT Solutions Limited. BQT Solutions and the BQT Solutions logo are registered trademarks of BQT Solutions (Australia) Pty Ltd. Mifare is a registered trademark of Philips Electronics. Drilling Template 9 series_v2.8.ai 15/08/2006 11:05:23 AM 9 series_v2.8 Aug06 UNITED KINGDOM & EMEA Global House, 1 Ashley Avenue, Epsom Surrey KT 18 5AD United Kingdom Phone: + 44 (0)20 8823 9350 Fax: + 44 (0)20 8823 9001 INSTALLATION GUIDE Version 2.8 CHINA Suite 1602, No.75, ShengDa Garden, 2518 LongHua Road, XuHui District, Shanghai 200232, P.R.China Tel: +86-21-5407 3638 Fax: +86-21-5407 3738 AUSTRALIA & ASIA PACIFIC Level 4, 65 Epping Road North Ryde NSW 2113 Australia Phone: +61 (0)2 8817 2800 Fax: +61 (0)2 8817 2811 AMERICA 30021 Tomas Street, Suite 300 Rancho Santa Margarita CA 92688 United States of America Phone: +1 877 278 2637 (ext 42) Fax:+1 877 278 2637 Alternatively contact us at one of our global locations For further technical information visit our website at www.bqtsolutions.com or email techsupport@bqtsolutions.com. Information contained in this document is subject to change without notice. miPASS 9 Series Mifare reader models IP rating IP 67 Colour Two toned – Silver & Charcoal Internal or external buzzer control Audible tone Green & Red Status LED’s 140mm (L) x 45mm (W) x 32mm (D) (5.51” x 1.77” x 1.26”) Reader dimensions 90% max, operating non-condensing Relative humidity -25ºC to +65ºC (-13ºF to 149ºF) Operating temperature Read range 20 - 60mm (0.8” – 2.4”)(typically) Activated Normal CMY CY MY DF900 - DESFire BT900 - Mifare miP9 - SPEK CSN9 - Card Serial Number 140mA 120mA Current consumption Power requirements Output protocols 12Vdc Wiegand 26-199 bit, RS485 or custom configurations (model dependent) Specifications CM ➣ BT900 (BT900W or WG) miP9/CSN9(BT900W ) Reader connections DF900/BT900(BT900D) 62mm 20mm Ø 4mm Ø NOTE: ➣➣ For all 9 Series readers ● 20mm (0.79”) diameter hole for wire entry ● 2 x 4 mm (0.16”) diameter holes for mounting screws ● Minimum reader dimensions are 140mm x 45 mm (5.51" x 1.77") Wiring Schematic Power Cable RED BLACK YELLOW ORANGE GREEN WHITE YELLOW/W GREEN/W BROWN/W BROWN/W +12Vdc 0V BUZ LED W0 W1 RS485A RS485B T1 T2 Power Supply +12Vdc 0V 0V BUZ LED W0 W1 Controller Cable Controller NOTE: If used with a shielded cable, the shield is connected to Controller 0V reference The 0V reference cable shall be included within the controller cable. The 12Vdc power cable shall NOT be included in the controller Cable. Only ONE power source is connected from the reader at any one time. RS485 - OPTIONAL USE TAMPER SWITCH AVAILABLE ON REQUEST 45mm Regulatory Information CE Mark The 9 Series has passed all relevant tests and obtained CE approval. C Tick The 9 Series has passed all relevant requirements for application of C Tick. 4mm Ø ➣ FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna - Increase the separation between the equipment and receiver - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected - Consult the dealer or an experienced radio/TV technician for help Designed & Manufactured in Australia Any changes or modifications not expressively approved by BQT Solutions could void the user's authority to operate this equipment. Copyright © 2006 BQT Solutions Limited. BQT Solutions and the BQT Solutions logo are registered trademarks of BQT Solutions (Australia) Pty Ltd. Mifare is a registered trademark of Philips Electronics. Drilling Template 9 series_v2.8.ai 15/08/2006 11:05:23 AM K CMY CY MY AUSTRALIA & ASIA PACIFIC Level 4, 65 Epping Road North Ryde NSW 2113 Australia Phone: +61 (0)2 8817 2800 Fax: +61 (0)2 8817 2811 AMERICA 30021 Tomas Street, Suite 300 Rancho Santa Margarita CA 92688 United States of America Phone: +1 877 278 2637 (ext 42) Fax:+1 877 278 2637 UNITED KINGDOM & EMEA Global House, 1 Ashley Avenue, Epsom Surrey KT 18 5AD United Kingdom Phone: + 44 (0)20 8823 9350 Fax: + 44 (0)20 8823 9001 CHINA Suite 1602, No.75, ShengDa Garden, 2518 LongHua Road, XuHui District, Shanghai 200232, P.R.China Tel: +86-21-5407 3638 Fax: +86-21-5407 3738 9 series_v2.8 Aug06 INSTALLATION GUIDE Version 2.8 Alternatively contact us at one of our global locations For further technical information visit our website at www.bqtsolutions.com or email techsupport@bqtsolutions.com. Information contained in this document is subject to change without notice. Read range 20 - 60mm (0.8” – 2.4”)(typically) Operating temperature -25ºC to +65ºC (-13ºF to 149ºF) Relative humidity 90% max, operating non-condensing Reader dimensions 140mm (L) x 45mm (W) x 32mm (D) (5.51” x 1.77” x 1.26”) Status LED’s Green & Red Audible tone Internal or external buzzer control Colour Two toned – Silver & Charcoal IP rating IP 67 miPASS 9 Series Mifare reader models DF900 - DESFire BT900 - Mifare miP9 - SPEK CSN9 - Card Serial Number Normal 120mA Activated 140mA Current consumption Output protocols Wiegand 26-199 bit, RS485 or custom configurations (model dependent) Power requirements 12Vdc Specifications Drilling Template For all 9 Series readers ● 20mm (0.79”) diameter hole for wire entry ● 2 x 4 mm (0.16”) diameter holes for mounting screws ● Minimum reader dimensions are 140mm x 45 mm (5.51" x 1.77") 4mm Ø 62mm 20mm Ø Wiring Schematic Reader connections DF815/BT815 (BT815D) BT815 (BT815W or WG) miP5/CSN5 (BT815W ) ➣ CM NOTE: ➣➣ Power Cable BUZ LED W0 W1 RS485A RS485B T1 T2 YELLOW ORANGE GREEN WHITE YELLOW/W GREEN/W BROWN/W BROWN/W +12Vdc 0V RED BLACK Power Supply +12Vdc 0V Controller Cable 0V BUZ LED W0 W1 Controller NOTE: If used with a shielded cable, the shield is connected to Controller 0V reference The 0V reference cable shall be included within the controller cable. The 12Vdc power cable shall NOT be included in the controller Cable. Only ONE power source is connected from the reader at any one time. RS485 - OPTIONAL USE TAMPER SWITCH AVAILABLE ON REQUEST Regulatory Information 45mm CE Mark The 9 Series has passed all relevant tests and obtained CE approval. C Tick The 9 Series has passed all relevant requirements for application of C Tick. FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 4mm Ø ➣ NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna - Increase the separation between the equipment and receiver - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected - Consult the dealer or an experienced radio/TV technician for help Designed & Manufactured in Australia Any changes or modifications not expressively approved by BQT Solutions could void the user's authority to operate this equipment. Copyright © 2006 BQT Solutions Limited. BQT Solutions and the BQT Solutions logo are registered trademarks of BQT Solutions (Australia) Pty Ltd. Mifare is a registered trademark of Philips Electronics. 9 series_v2.8.ai 15/08/2006 11:05:23 AM smart_mullion_v1.0 Mar05 www.pac.co.uk customer_services@pac.co.uk T: +852 2638 1688, F: +852 2851 1688 Unit 310, Technology Park, 18 On Lai Street, Sha Tin, Hong Kong T: +852 2638 1688, F: +852 2851 1688 Blick House, Cambridge Commercial Park, 6 Trinity Close, Paulshof, Sandton, South Africa T: +27 11 8443200, F +27 11 8033117 Smart Mullion Reader Installation Guide 1 Park Gate Close, Bredbury, Stockport, SK6 2SZ, England T: +44 161 406 3400. F: +44 161 430 8658 PAC INTERNATIONAL LTD A Stanley Security Solutions Business Reader Specifications Smart Standard Mullion Drilling Template 20mm (0.79”) hole for wire entry 2 x 4 mm (0.08” x 0.16”) holes for mounting screws Minimum outer dimension is 140 mm x45 mm (5.51” x 1.77”) so as not to interfere with any other components Reader Output PAC proximity format Power requirements 12Vdc Current Consumption (+/- 5%) Normal 120mA Activated 62 140mA Read range 20 - 60mm (0.8” – 2.4”)(typically) Cable distances 0.22mm cable 100m max 0.33mm cable 250m max Operating temperature -10ºC to +55ºC (14ºF to 131ºF) Relative humidity 90% max, operating non-condensing Reader dimensions 140mm x 45mm x 32mm (5.51" x 1.77" 0.79") Status LED’s Green/Red controlled by access controller Audible tone Controlled by access controller Colour Two toned - Silver & Charcoal IP rating IP 67 Regulatory Information 45 CE Mark The reader has passed all relevant tests and obtained CE approval. C Tick The reader has passed all relevant requirements for application of C Tick. FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna - Increase the separation between the equipment and receiver - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected - Consult the dealer or an experienced radio/TV technician for help Any changes or modifications to this product not expressly approved in this document could void the user's authority to operate this equipment. Designed & Manufactured in Australia. Mifare is a registered trademark of Philips Electronics. ® Introduction Wiring 1. Read the instructions before wiring. 2. The request to exit and door contact can be wired for 4-state if required. Note Smart Mullion Reader Using two readers, for in and out, on one door channel will require one reader to be powered separately. See Technical Bulletin TB151 "How to Connect High-Current Readers to PAC Access Controllers" 1. Connect the wiring as indicated in the diagram to the socket. Check your circuit diagram for the colour coding of the circuit wiring. Connect the 0V reference and 0V (if provided in the power supply) to the ground (GND) Wire. Connect the signal and optional wires. Connect the LED wire. Connect the +12Vdc wire last. White Optional Back Box The reader outputs a PAC format suitable for PAC 202/512 access controllers. They are used in security applications and can be installed in new installations or as an upgraded reader in existing proximity access control systems. Each reader incorporates a LED which is controlled by the security system and provides feedback to a person wishing to enter. 2. 3. 4. Place the reader on the wall. Make sure the wires are not crushed. Insert and hand tighten the screws. Check that the reader is level before tightening the screws. Excessive tightening of screws may deform the casing, resulting in a damaged unit. THIS WILL VOID THE WARRANTY. External Use Mount the reader on a suitable external single gang surface mount box. Make sure that the wire bundle to the reader has an IP rating of at least IP67. Use warming pads if the temperature of the reader is expected to fall below -10ºC (14ºF). 5. 6. Replace the cover. Power up the reader. Note Handling Handle the reader with care. Do not damage/drop unit before installation. The unit needs approximately 13 seconds to set up before it can respond to a valid smart card. Smart Mullion Reader Installation Maintenance 1. Once installed the reader requires no maintenance Remove the cover by holding the unit as shown and pulling the cover from the top as illustrated. Troubleshooting If the reader doesn't respond when a valid smart card is presented, check the following: 2. 3. 4. If necessary, drill holes for the mounting screws in the wall or mounting box on which the reader unit will be placed. Use the template provided. Alternately a back box can be used. Place the controller and power supply cable through the grommit hole. Drill the holes in the wall as indicated by the arrows. Make sure that you don't drill through the cable. 62 45 Symptom Possible Cause Check LED is not lit No power to the reader Check the power supply to the reader. LED is orange/indeterminate or buzzer sounds low Voltage to the reader is below minimum required level Check the power supply to the reader Reader doesn't respond Invalid card or card is faulty or Wiring to the controller is faulty. Check reader with another valid smart card; if problem persists check wiring If the problem still exists, uninstall the reader and send it back to the PAC. If the reader is within the warranty period then another will be sent free of charge. Warranty Each reader comes with a 3-year warranty from the date of dispatch. The warranty is void if the instructions contained within this document have not been adhered to.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Modify Date : 2006:10:02 11:55:30+10:00 Create Date : 2006:09:26 17:46:00+10:00 Page Count : 11 PDF Version : 1.6 About : uuid:bdeb6a33-2624-439d-852a-5e36bce7fcc0 Producer : Acrobat Distiller 6.0 (Windows) Creation Date : 2006:09:26 17:46:00+10:00 Mod Date : 2006:10:02 11:55:30+10:00 Author : Les Dickenson Creator Tool : PScript5.dll Version 5.2 Metadata Date : 2006:10:02 11:55:30+10:00 Document ID : uuid:4c76c6d1-2a93-414a-a774-8757a679a515 Format : application/pdf Title : Microsoft Word - APPENDIX L_User Manual t60821_F.doc Creator : Les DickensonEXIF Metadata provided by EXIF.tools