Badger Meter 2002C Orion Pit User Manual RTR ORION Pit p65

Badger Meter Inc Orion Pit RTR ORION Pit p65

Exhibit D Users Manual per 2 1033 b3

Download: Badger Meter 2002C Orion Pit User Manual RTR ORION Pit p65
Mirror Download [FCC.gov]Badger Meter 2002C Orion Pit User Manual RTR ORION Pit p65
Document ID250714
Application ID7l4wjyQJfsUAkcdamjK9dw==
Document DescriptionExhibit D Users Manual per 2 1033 b3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize33.39kB (417425 bits)
Date Submitted2002-06-17 00:00:00
Date Available2002-06-14 00:00:00
Creation Date2002-05-31 13:45:03
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2002-05-31 13:45:04
Document TitleRTR ORION Pit.p65
Document CreatorPageMaker 6.5
Document Author: nowakca

RTR® - Pit ORION®
Recordall® Transmitter Register for
Pit ORION®
Technical
Brief
DESCRIPTION
APPLICATIONS: The Badger ® RTR® Pit ORION ® RF system is designed
for water meter pit or vault installations that are subject to flooding or
submergence. The assembled system consists of the Recordall®
Transmitter Register (RTR ®) and the ORION Pit Module. The RTR is
factory wired to the end cap assembly for maximum reliability; the Pit
ORION is bottom mounted thru a drilled hole in the meter pit lid.
The assembled RTR Pit ORION is designed to communicate with
Badger interrogation devices, including handheld or mobile.
OPERATION: The RTR provides a digital signal from Badger Meter's
patented piezoelectric solid-state switch. This signal has the
characteristics of an open drain Field Effect Transistor (FET) and has
no electrical contacts to stick, wear or corrode. It is fully compatible with
the input circuitry of the ORION Pit Module. The ORION Pit Module uses
the RF bubble-up (broadcast) mode.
RESOLUTION: Digital output from the RTR has resolution of 1/10th of
the register test circle. Output resolution of the Pit ORION Module may
vary with meter size. The resolution table on the back of this technical
brief lists output resolution for all ORION meter applications.
LEAK DETECTION: The Orion system provides optional leak detection
notification when the meter is read. The system reports leak detection
when a two hour window of no usage is found within a 24 hour time
period. The system automatically resets when the next two hour window
of no usage is found.
MOUNTING: The RTR uses a bayonet connection compatible with all
Recordall ® Disc, Turbo, Compound and Fire Series meters. A TORX®
seal screw is provided to allow positioning and to secure the RTR to the
meter body in a tamper resistant mode. The RTR can be removed from
the meter without disrupting service or disconnecting the Pit ORION.
The RTR is factory wired to the Pit ORION Module.
For best performance, the Pit ORION is mounted through the drilled hole
in the lid, attached to the lid, and programmed by the utility in the field.
If the Pit ORION system is mounted below the lid (not through the
drilled hole) reduced performance will result.
MAGNETIC DRIVE: Direct drive, high-strength, magnetic coupling
through the meter body to the wetted magnet provides reliable and
dependable register coupling.
SPECIFICATIONS
Transmitter/Register
Unit of Measure
U.S. Gallons, Cubic Feet, Cubic Meters,
clearly identified on register face
Number Wheels
Six with 3/16" high numerals
Namel font type
Test Circle
Weight
Humidity
SEALED REGISTER: The RTR local register consists of a six-digit
straight-reading mechanical odometer totalizer, a 360° test circle with
sweep hand, and a flow finder to detect leaks. The register gearing is
self-lubricating, thermoplastic to minimize friction and provide long,
reliable life. Permanent sealing eliminates moisture, dirt, and other
contaminants.
Signal Characteristics
TAMPER-PROOF FEATURES: Removal of the RTR from the meter can
be minimized by using a tamper resistant TORX seal screw. TORX seal
screws are provided as standard accessories with the RTR. Optional
tamper detection seal wire screws are also available.
Typical Signal Duration
CUT WIRE TAMPER INDICATION: The Pit ORION has the capability
to detect a tamper should it exist. Proper setup in ORION Reading
System software needed.
On State Resistance
CONSTRUCTION: The housing of the RTR is constructed of a tempered
glass lens top and a copper alloy metal bottom. Internal construction
materials are thermoplastic for long-life and high reliability. The integrity
of the adhesive seal joining the glass top to the metal base provide
unmatched protection in water meter applications. A corrosion and
tamper resistant TORX seal screw is provided to secure the RTR to the
meter. The shroud assembly is polycarbonate.
The housing of the Pit ORION is constructed of a polycarbonate
material.
Straight reading, permanently sealed,
magnetic drive
Visual Resolution
Electronic Resolution
Power Source
360° circle with ten major increments with
ten divisions each
9 Ounces
0% to 100% Condensing
Open Drain (FET)
1/100th of Test Circle
1/10th of Test Circle
15 ms to 75 ms @ 25°C (77°F)
8 ms to 75 ms over operating temperature
range at 67 µA
7.5 Ohms @ 25°C (77°F)
External
Maximum Switching
30 VDC @ 1 mA @ 25°C (77°F)
Battery on Pit ORION
(2) 3.6V 2.4 Ahr Lithium Batteries
See Badger Technical Brief RTR-T-05 for RTR® specifications.
TEMPERATURE: The operating range of the RTR is -40°C to 49°C (40°F to 120°F). The operating range of the Pit ORION is -40°C to 60°C
(-40°F to 140°F). The water meter should not be subjected to temperatures below freezing.
BadgerMeter,Inc.
®
RTR-T-36
5-02
MOISTURE: The RTR is permanently sealed and designed for
submerged meter pit applications. The RTR Pit ORION system is also
designed for flooded or submerged meter pit locations.
WIRE CONNECTIONS: The RTR can be factory prewired with presized wire harness of either 5 or 20 feet to the ORION Pit Module.
ELECTRONICS: The piezoelectric switch circuit board is completely
sealed against moisture inside the unit and sealed to ensure protection
from humidity. The Pit ORION Module is designed to protect against
the effects of humidity.
Gallons
Resolution
Cubic
Feet (Ft3)
Resolution
Cubic
Meters (m3)
5/8"
0.1
0.01
M25
3/4"
0.1
0.01
M35
3/4"
0.1
0.01
RECORDALL
Model
Size
M25
ELECTRICAL: The electronic circuitry of the RTR and Pit ORION
Module is designed to provide immunity to electrical surges and
transients per IEC801-2, IEC801-4 Severity Level 4.
M70
1"
0.1
0.01
M120
1 1/2"
10
0.1
M170
2"
10
0.1
OPERATING CHARACTERISTICS: The RTR has an output equal
to 1/10th of the meter test circle with the characteristics of an open drain
FET. The on-state condition is a solid-state switch closure. Off-state
condition is an open circuit. Powered by an external source, the RTR
has a maximum rating of 30 VDC at 1 mA (25°C).
RECORDALL
Turbo Series
(Size)
Gallons
Resolution
Cubic
Feet (Ft3)
Resolution
Cubic
Meters (m3)
PATENT: The Badger RTR Pit ORION application is covered by US
patent number 5,298,894.
2"
100
10
0.1
3"
100
10
0.1
TRANSPORTATION WARNING: The Federal Aviation Administration
prohibits operating transmitters and receivers on all commercial
aircraft. When powered, the Pit ORION Module is considered an
operating transmitter and receiver and cannot be shipped by air.
4"
100
10
0.1
6"
100
10
8"
100
10
MEASUREMENT RESOLUTION: The minimum electronic resolution
of the RTR is noted to the right. To verify the correct resolution for your
application, contact Badger Meter Customer Solutions.
10"
100
10
12"
1000
100
16"
1000
100
20"
1000
100
®
METER COMPATIBILITY: Badger Meter's Recordall Disc, Turbo,
Compound, and Fire Series meters.
LICENSE REQUIREMENTS
Badger®, ORION® , Recordall® and RTR® are registered trademarks of Badger Meter, Inc.
TORX® is a registered trademark of Camcar, Division of Textron, Inc.
Please see our website at
This device complies with Part 15 of the FCC Rules. Operation of this
device is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation. Any changes made by the user not approved by Badger
Meter can void the user's authority to operate the equipment. No license
is required by the utility to operate a ORION meter reading system.
Due to continuous research, product improvements and enhancements,
Badger Meter reserves the right to change product or system specifications
without notice, except to the extent an outstanding bid obligation exists.
www.badgermeter.com
BadgerMeter,Inc.
for specific contacts.
Copyright © Badger Meter, Inc. 2002. All rights reserved.
®
P.O. Box 245036, Milwaukee, WI 53224-9536
(800) 876-3837 / Fax: (888) 371-5982
www.badgermeter.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Create Date                     : 2002:05:31 13:45:03
Producer                        : Acrobat Distiller 4.0 for Windows
Author                          : nowakca
Creator                         : PageMaker 6.5
Title                           : RTR ORION Pit.p65
Modify Date                     : 2002:05:31 13:45:04-05:00
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GIF2002C