Badger Meter ORIONGAS Orion Gas Transmitter User Manual 425088

Badger Meter Inc Orion Gas Transmitter 425088

Exhibit D Users Manual per 2 1033 b3

Download: Badger Meter ORIONGAS Orion Gas Transmitter User Manual 425088
Mirror Download [FCC.gov]Badger Meter ORIONGAS Orion Gas Transmitter User Manual 425088
Document ID425088
Application IDgBQ5ufhw7r9A4L4G9kKLkg==
Document DescriptionExhibit D Users Manual per 2 1033 b3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatMicrosoft Word - pdf
Filesize152.21kB (1902593 bits)
Date Submitted2004-05-25 00:00:00
Date Available2004-05-25 00:00:00
Creation Date2004-05-25 08:14:26
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2004-05-25 08:14:26
Document TitleMicrosoft Word - 425088.DOC
Document CreatorPScript5.dll Version 5.2
Document Author: Administrator

PRELIMINARY
FOR REVIEW ONLY (040604)
ORION®
Automated Meter
Reading System
ORION Integral
Transmitter for Gas Meters
INSTALLATION
DATA
IDENTIFICATION
ORION integral transmitters for Gas Meters are designed for use with a variety of major
brands of hardcase gas meters. Although the basic design of the transmitter is the same,
slight variations are required to adapt the transmitter to different gas meter
configurations. A model number code that corresponds to the different makes and models
of gas meters is used to identify each transmitter relative to the gas meter on which it is to
be used. Refer to the identification table listed within this document.
IDENTIFICATION TABLE
Gas Meter Mfgr
Gas Meter Model
American Meter
AL-175
Invensys/Rockwell/Equimeter R-175 11 tooth
Actaris
175
ORION Transmitter #
64989-002
64989-001
64989-003
SUGGESTED INSTALLATION TOOLS AND MATERIALS
1/8” flat blade screwdriver
¼” flat blade screwdriver
3/8” flat blade screwdriver
#1 Phillips
Pliers (wire-cutting, long-nose and utility)
Optical programming probe and laptop
TRANSMITTER INSTALLATION
For specific transmitter model installation instructions, refer to the installation data
supplied with each transmitter shipment. Because of the vast differences in the various
types and models of gas meters, it is not practical to discuss a generic installation
procedure for the Orion transmitter. However, the following list of helpful installation
tips will generally provide trouble-free operation.
•
•
•
•
Before proceeding with the installation, make sure that the transmitter model
number matches the model number of the gas meter.
Remove the cover seal screws and housing cover from the gas meter index.
Use care in handling the Orion transmitter to insure that the drive pawl is not
subjected to any physical abuse which might cause this drive spindle to become
bent, misaligned, or otherwise inoperative.
When mounting the transmitter to the gas meter, make sure that the meter drive
dog engages the transmitter drive pawl and that these two drive pawls mate
without causing any binding or potential for disengagement.
•
When attaching the gas meter index to the Orion transmitter, make sure the meter
index mounts securely to the transmitter and that the two drive pawls mate
without causing any binding or potential for disengagement.
PROGRAMMING AN ORION TRANSMITTER
A. Plug the Optical probe into the laptop.
B. Start the Orion Optical Probe software.
C. Place the Optical probe near the optical port on the Orion transmitter (define
location)
D. Select the Read Option
E. The transmitter ID number will appear in the Serial # block. The current reading
will appear in the Odometer # block. The Status box will indicate the
communication steps and success of each.
F. If reading is unsuccessful, reposition the Optical probe and try again.
G. Once a successful read is obtained, verify the Serial # matches the tag on the
transmitter.
H. Compare the Odometer # to the register’s odometer reading. The Orion reading
will include the moving indices.
I. Enter a new Odometer reading, if required. Include each of the moving indices.
J. Place the Optical probe in position over the optical port of the transmitter.
K. Select the Set Odometer button.
L. Monitor status box to verify successful programming.
M. If programming is unsuccessful, verify ID number and odometer #, reposition the
Optical probe and try again.
N. Once programming is complete, you may want to verify success. With the Optical
probe in place, touch Read and verify the reading. Remember the Orion odometer
reading will include each of the moving indicies.
COMPLETE THE INSTALLATION
• Replace the housing cover over the index and insert and tighten the cover seal
screws.
• Attach seal wires and insert security cap seals.
LICENSE REQUIREMENTS
This device complies with Part 15 of the FCC Rules. Operation of this device is subject
to the following condition: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause
undesired operation. Any changes made by the user not approved by Badger Meter can
void the user’s authority to operate the equipment. No license is required by the utility to
operate an ORION meter reading system.


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2004:05:25 08:14:26-04:00
Modify Date                     : 2004:05:25 08:14:26-04:00
Page Count                      : 3
Creation Date                   : 2004:05:25 12:14:26Z
Mod Date                        : 2004:05:25 12:14:26Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : Administrator
Metadata Date                   : 2004:05:25 12:14:26Z
Creator                         : Administrator
Title                           : Microsoft Word - 425088.DOC
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GIFORIONGAS

Navigation menu