Baicells Technologies CW0100 LTE Outdoor CPE User Manual BaiCells CW0100 CPE Installation Guide
Baicells Technologies Co., Ltd. LTE Outdoor CPE BaiCells CW0100 CPE Installation Guide
Contents
- 1. User Manual
- 2. Users Manual
User Manual
BaiCells CW0100 CPE Installation Guide V1.0 All rights reserved © BaiCells Technologies Co., Ltd. About This Document This document introduces the installation and debugging steps of CW0100 outdoor CPE equipment, which is used for guiding installer to install CPE correctly. Copyright Notice BaiCells copyrights this specification. No part of this specification may be reproduced in any form or means, without the prior written consent of BaiCells. Disclaimer This specification is preliminary and is subject to change at any time without notice. BaiCells assumes no responsibility for any errors contained herein. For more information, please consult our technical engineers. Revision Record Date 30 Jun,2016 Version Description Author V1.0 Initial released. Tang Houcheng Contact Us E-mail: support@baicells.com Phone: 86-10-62607100 Website: http://www.baicells.com/ Contents 1. 2. 3. 4. 5. Installation Preparation ................................................................................................. 2 1.1 Out-of-Box Audit ...................................................................................................... 2 1.2 Installation Accessories .............................................................................................. 2 1.3 Installation Tools ...................................................................................................... 3 1.4 Installation Environment ............................................................................................ 4 1.5 Safety Protection ........................................................................................................ 4 Equipment Installation ................................................................................................... 5 2.1 Appearance ............................................................................................................... 5 2.2 Interface and Button .................................................................................................. 5 2.3 LED Indicators............................................................................................................. 6 2.4 RF Specifications......................................................................................................... 6 2.5 Install on Pole ............................................................................................................. 7 2.6 Install on Wall ............................................................................................................. 8 Wire Connection ............................................................................................................. 9 3.1 Make Ethernet Cable Connector ............................................................................. 9 3.2 Connect Ethernet Cable ......................................................................................... 13 3.3 Power On .................................................................................................................. 14 3.4 Lightning Protection of Cable ................................................................................... 15 Power on Detection ...................................................................................................... 16 4.1 Detection Item ........................................................................................................ 16 4.2 Ethernet Port Working Status .................................................................................. 16 4.3 CPE Configuration Check .......................................................................................... 16 4.4 CPE Access Test ........................................................................................................ 16 4.5 CPE Parameter Record ............................................................................................. 16 Regulatory Compliance ................................................................................................ 17 Appendix A FAQ............................................................................................................... 19 Contents of Figure Figure 2-1 Appearance of CW0100.............................................................................. 5 Figure 2-2 Install on pole A........................................................................................... 7 Figure 2-3 Install on pole B .......................................................................................... 8 Figure 2-4 Mounting Hole of Install on Wall ................................................................. 8 Figure 3-1 Strip Shielded Twisted Pair ......................................................................... 9 Figure 3-2 Separate the metal net, wire of cable and aluminum foil layer .................. 9 Figure 3-3 Cut off the aluminum foil layer of twisted pair ........................................... 10 Figure 3-4 Color Order ............................................................................................... 10 Figure 3-5 Insert the twisted pair core into line card .................................................. 10 Figure 3-6 Insert line card into Connector .................................................................. 11 Figure 3-7 Crimping connector ................................................................................... 11 Figure 3-8 Impact the connector with cable shield layer ............................................ 11 Figure 3-9 Cut off the redundant part ......................................................................... 12 Figure 3-10 Completion of shielded connector .......................................................... 12 Figure 3-11 Connect Cable 1 ..................................................................................... 13 Figure 3-12 Connect Cable 2 ..................................................................................... 14 Figure 3-13 POE power Mode.................................................................................... 15 Contents of Table Table 2-1 CW0100 Interface and button ...................................................................... 5 Table 2-2 LED Indicators .............................................................................................. 6 Table 2-3 RF Specification ........................................................................................... 6 Table 3-1 Lightning Protection Demand of Cable ...................................................... 15 1. Installation Preparation 1.1 Out-of-Box Audit Before opening the box, make sure the packaging cases are in good condition, undamaged and not soaked. During the unpacking, avoid potential damaging impacts from hits or excessive force. Check whether the material in the box is consistent with “Shipping List” and is in good condition and undamaged. Note: During the unpacking, if the outer package is damaged or soaked, stop unpacking and find the cause. Report the issue to the vendor. For any shortage, miscarriage, or damage is identified, report the local vendor within 10 days. 1.2 Installation Accessories Figure Name Shielded RJ-45 connector and line card POE power adaptor Figure Name Shielded CAT5 twisted pair The length of the cable is tailored according situation of the installation site. Plastic tie Grounding wire 1.3 Installation Tools The following tools are needed during the installation. Standing wave measuring instrument Percussion drill and some drill Nipper pliers Tool knife Diagonal pliers Pincer pliers Screwdriver Crimping tool Ethernet cable tester Multimeter Wrench 1.4 Electroprobe Electric soldering iron Ladder Installation Environment According to “Reconnaissance Report”, check whether the external environment of installation site is ready. 1.5 Safety Protection Construction personnel must conform to “Construction Safety Specification”, wearing safety protection guard, such as safety belt, safety helmet, gloves, and wrist strap, and so on. 2. Equipment Installation 2.1 Appearance The appearance of CW0100 outdoor CPE is smart, the dimension of CPE is 245mm x 135mm x 42mm, the weights of CPE is 600g. The appearance is shown in Figure 2-1. Figure 2-1 Appearance of CW0100 CW0100 CPE support installing on pole or installing on wall. The following introduces the two ways separately. Caution: The direction of CPE cable exit end must be down. 2.2 Interface and Button Table 2-1 CW0100 Interface and button Connectors ETH RJ45 Description One LAN USIM Slot Support 1.8V/3.0V USIM Restore Button Long press over 10s to restore the factory settings 2.3 LED Indicators Table 2-2 LED Indicators LED Name PWR LTE Signal LAN 2.4 Description Color LED Behavior Status Indicator Power Indicator Green OFF No Power Supply Steady On Power On 3 LTEs, Indicate connection state and signal strength Green All OFF No Connected ALL blanking Connecting One LED Steady On Connected, the signal is weak Two LED Steady On Connected, the signal is medium Three LED Steady On Connected, the signal is strong OFF Ethernet connection is not established Steady On Ethernet connection is normal Blanking Ethernet interface data being transmitted Eth Indication Green RF Specifications Table 2-3 RF Specification Feature Mode Capability Value TDD Unit Channel Bandwidth 5/10/15/20 MHz Max Output Power 24 dBm LTE Standard 3GPP R9 Frequency 3650 ~ 3700 MHz Antenna Gain 11 dBi 2.5 Install on Pole Installing on pole have three methods: traditional on pole, telegraph on pole and iron on tower. Traditional on pole: Required diameter of the pole is 25mm to 45mm. Telegraph on pole: If the pole is telegraph, you need to install a pole that length is over 700mm and diameter is 25mm to 45mm as the mounting bracket. Iron on tower: If CPE is installed on iron tower, you need to choose vertical direction angle iron as the mounting bracket. The length is about 25mm to 45mm. Installation steps is as follows: 1. Loosen iron hold hoop use the screw driver, make the hold hoop through the mounting hole and fix with the pole. Figure 2-2 Install on pole A Iron hold hoop 2. Locking the iron hold hoop use screw driver, fasten the CPE with the pole. Figure 2-3 Install on pole B Fasten the screw using screw driver 2.6 Install on Wall When CW0100 installs on wall, the installation method is as follows: On the wall, fix two big head screw which distance is 52mm, and then hang the CPE on the big head screw. Figure 2-4 Mounting Hole of Install on Wall Mounting hole of install on wall 3. Wire Connection 3.1 Make Ethernet Cable Connector CW0100 outdoor CPE need to use shielded CAT5 twisted pair, the operation steps of making connector is as follows:: 1. Before making the RJ-45 shielded connector, strip the outer Jacket of the twisted pair about 30mm using crimping tool, which is shown in Figure 3-1. Figure 3-1 Strip Shielded Twisted Pair 2. Separate the metal net, wire of cable and aluminum foil layer of twisted pair, as shown in Figure 3-2. Figure 3-2 Separate the metal net, wire of cable and aluminum foil layer 3. Cut off the aluminum foil layer of twisted pair using diagonal pliers, as shown in Figure 3-3. Figure 3-3 Cut off the aluminum foil layer of twisted pair 4. The mode of connection is standard straight through cable. The color order is white/orange, orange, white/green, blue, white/blue, green, white/brown, brown, which is shown in Figure 3-4. The color order is important to get corrected. Figure 3-4 Color Order 5. Insert the eight wires into the line card according to the color order, shorten them to a suitable length (about 12 mm) using diagonal pliers, as shown in Figure 3-5. Figure 3-5 Insert the twisted pair core into line card 6. Insert the line card having passed through eight wires into shielded connector, ensure that the wires go to the end. The line card that one side is plane, the other side is convex, ensure that the shielded connector match with the line card, as shown in Figure 3-6. 10 Figure 3-6 Insert line card into Connector 7. Crimping the cable using crimper, as shown in Figure 3-7. Figure 3-7 Crimping connector 8. Impact the metal part of the shielded connector tail with the metal net shielded layer of the Ethernet cable using nipper pliers, as shown in Figure 3-8. Figure 3-8 Impact the connector with cable shield layer 11 9. Cut off the redundant part of metal net using diagonal pliers, as shown in Figure 3-9. Figure 3-9 Cut off the redundant part 10. After the completion of shielded connector making, as shown in Figure 3-10. Repeat all the steps and wire color on the other end of the cable. Figure 3-10 Completion of shielded connector 11. Test whether the cable is normal using Ethernet cable tester. After the completion of two ends making, use Ethernet cable tester to test whether it 12 is normal. In the tester, if eight signal indicator and grounding indicator flash green in turn, it indicates that the Ethernet cable is normal. If any signal indicator is red or yellow, it indicates that there is circuit break or bad contact. You need to make a new connector again. 3.2 1. Connect Ethernet Cable Connect the shielded cable to WAN interface of CPE, as shown in Figure 3-11. Figure 3-11 Connect Cable 1 2. After connecting the Ethernet cable, cover the slide of CPE, as shown in Figure 3-12. 13 Figure 3-12 Connect Cable 2 3. Connect to POE power. One end of the cable connect to CPE and the other end connect to POE power. Fix the cable on the pole using plastic tie close to CPE about 20cm, preventing the damage of the cable waggling with the wind. It is recommended that the cable is fixed by plastic tie at intervals of 50cm until POE power. If the length of outdoor is too long, you need to protect the cable with metal shielded flexible sleeve. 3.3 Power On CW0100 outdoor CPE is powered with POE. CPE provides standard POE power interface conformed to IEEE 802.3af standard. The 4, 5 (+), 7, 8 (-) wire have direct current. Before power on, test whether there is voltage output and whether voltage output is inverse with multimeter. Power on CW0100 CPE with POE supply: 1. Connect DATA IN port of POE adaptor to one of a switch port with Ethernet cable. 2. Connect one end of grounding wire to PE terminal of POE adaptor and fasten it, the other end of grounding wire connect to grounding device. 3. Connect DATA&POWER OUT port of POE adaptor to POE port of CW0100 with Ethernet cable. Place POE adaptor and switch in the room, which is shown in Figure 3-13. 14 Figure 3-13 POE power Mode 3.4 Lightning Protection of Cable It need to use shielded cable and ensure the grounding of two ends of equipment. If the opposite equipment has plastic enclosure, which cannot be grounding. In this situation, the shielded cable function is decreased largely. If its available, it is recommended that Ethernet cable and power cable pass through metal sleeve to ground separately. And they cannot be in a same metal sleeve. It is highly recommended that the distance is as nearest as possible between the two equipment connected by Ethernet cable, avoiding the cable hanging in the air. According to the wiring environment, the lightning protection demand is different, the details is described in Table 3-1. Table 3-1 Lightning Protection Demand of Cable Number Environment Lightning Protection Demand Completely in indoor or underground No special demand Outdoor part exceed 3m 4KV(10/700us) Outdoor part exceed 10m 3KA Outdoor part exceed 10m, and application environment is poor, such as the cable hanging in the air, strong lightning area, and so on. 5KA 15 4. Power on Detection 4.1 Detection Item Power on detection includes the following four items: Ethernet port working status CPE configuration check CPE access test CPE parameter record 4.2 Ethernet Port Working Status After CPE powered on, waiting for 2 minutes, connect the Ethernet port of PC to POE adaptor. The CW0100 CPE default IP address is 192.168.1.1. Set the IP address of PC is 192.168.1.2, ensure that the Ethernet indicator get light and ping CPE IP address normal. 4.3 CPE Configuration Check Log in the WebUI of CPE, check whether the software version is correct, whether the LTE mode is enabled, and whether WAN interface and LAN interface are consistent with plan. 4.4 CPE Access Test Insert into USIM card, set the WAN interface to LTE mode, set LTE to auto connection, check terminal connection status, and check whether the terminal can san LTE signal and get IP address. After the connection is established, service testing can be made, such as HTTP, FTP, and so on. 4.5 CPE Parameter Record Record parameter of CPE, such as installation site, installation height, antenna direction angle, and so on. 16 5. Regulatory Compliance FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Warning This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. 17 IC Compliance This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. 18 Appendix A FAQ CPE is unable to power on Check whether POE power is connected normal. Check whether the Ethernet cable is damaged and wire order is correct. CPE service is unable to running Check whether it is correct that the network normal configuration of CPE. Check whether the CPE have connected to LTE network. CPE receive download signal weak If external antenna is used, check whether antenna feed system have connected normal. (The standing wave measuring can be used.) Check whether the internal coaxial-cable gets loose. CPE is unable to connect base station Check whether it is normal that the CPE receives signal. Check whether the software version that CPE has download is consistent with the software version of base station. Check the data card frequency band of CPE is consistent with the base station. 19
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author : Administrator Create Date : 2016:07:06 14:44:43+08:00 Modify Date : 2016:07:06 18:47:28-07:00 Subject : V1.0 Language : zh-CN Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : Administrator Description : V1.0 Title : BaiCells CW0100 CPE Installation Guide Creator Tool : Microsoft® Word 2010 Metadata Date : 2016:07:06 18:47:28-07:00 Producer : Microsoft® Word 2010 Document ID : uuid:baa8c5a1-f671-4a4d-b0b6-0e2544316205 Instance ID : uuid:3ba906ad-c792-4b0e-aaa8-9b8d6c87093d Page Count : 23EXIF Metadata provided by EXIF.tools