   About This Document This document introduces the specifications of Baicells EG2030C-M2 CPE and guides users to install and configure it.  Copyright Notice Baicells copyrights this specification. No part of this specification may be reproduced in any form or means, without the prior written consent of Baicells.  Disclaimer This  specification  is  preliminary  and  is  subject  to  change  at  any  time  without  notice. Baicells assumes no responsibility for any errors contained herein. For more information, please consult our technical engineers.  Disposal of Electronic and Electrical Waste Pursuant to the WEEE EU Directive, electronic and electrical waste must not be  disposed  of  with  unsorted  waste.  Please  contact  your  local  recycling authority for disposal of this product.  Revision Record Date Version Description 5 June,2017 V1.0 Initial released.         Contact Us Baicells Technologies Co., Ltd.North America   Address: 555 Republic Drive, Suite 200 Plano, TX 75074 E-mail: support_na@baicells.com Phone: +1-972-800-1157 Website: http://www.baicells.com/
   Contents 1. Product Overview ......................................................................................................... 1 1.1 Introduction .............................................................................................................. 1 1.2 Features ..................................................................................................................... 1 1.3 Appearance ............................................................................................................... 1 2. Technical Specifications ............................................................................................... 4 2.1 Basic Specification .................................................................................................... 4 2.2 RF Specification ........................................................................................................ 4 2.3 SW Specification ....................................................................................................... 5 2.4 Device Management .................................................................................................. 5 2.5 Environment Specification ......................................................................................... 6 2.6 Regulatory Compliance .............................................................................................. 6 3. Configuration Guide ..................................................................................................... 8 3.1 Log in .......................................................................................................................... 8 3.2 View Status ................................................................................................................. 8 3.3 Basic Configuration .................................................................................................... 9 3.3.1 LTE Setting .......................................................................................................... 9 3.3.2 Set Connection Method ...................................................................................... 9 3.3.3 Set Scan Mode .................................................................................................. 10 3.3.4 Lock Frequency (Earfcn) ................................................................................... 10 3.3.5 Lock PCI ............................................................................................................. 11 Appendix A FAQs ......................................................................................................... 13 Appendix B Shipping List ............................................................................................. 14
   Figures Figure 1-1 EG2030C-M2 Appearance .......................................................................... 2 Figure 1-3 LED Indicators of EG2030C-M2 ................................................................. 2 Figure 4-1 Login Page .................................................................................................. 8 Figure 4-2 View Status ................................................................................................. 9 Figure 4-3 Set Connection Method .............................................................................. 9 Figure 4-4 Set Scan Mode ......................................................................................... 10 Figure 4-5 Lock Frequency ........................................................................................ 11 Figure 4-6 Lock Frequency ........................................................................................ 12
   Tables Table 1-1 Description of EG2030C-M2 Interface and Button ....................................... 2 Table 1-2 LED Indicator Description ............................................................................. 3 Table 2-1 Basic Specification ....................................................................................... 4 Table 2-2 RF Specification ........................................................................................... 4 Table 2-3 SW Specification .......................................................................................... 5 Table 2-4 Device Management ..................................................................................... 5 Table 2-5 Environment Specification ............................................................................ 6
 1  1. Product Overview 1.1 Introduction Baicells is a high-tech company dedicated in wireless broadband access solutions and service  operation.  With  the  advent  of  the  Internet+  era,  the  development  of  WBB  is imminent.  Through  continuous  innovation,  Baicells  launches  the  world  first  mobile broadband system based on the Internet architecture and unlicensed spectrum. Baicells can provide series CPEs, include indoor and outdoor unit on different spectrums. Baicells  EG2030C-M2  is  high  performance  outdoor  CPE.  The  EG2030C-M2  has  the superior  wireless  access  performance  and  comprehensive  routing  capabilities,  which have the abilities to bring the end-users WBB services. 1.2 Features The EG2030C-M2 is designed according to the simplicity principle, which can evolve in a short period and realize fast customization, delivery and deployment as well. The main features of the EG2030C-M2 is as follows:   Support TD-LTE network according to the operator’s choice.   LTE comply with 3GPP Release9 CAT4.   LTE TDD band42&band43.   Support the 100Mbps Ethernet interface.   Support 802.11bgn.   Intuitionist and convenient Web-based management.   Support TR069 and OMA-DM network management protocol.   Support cell lock, SIM lock, and Pin lock.   User-friendly design of LED indicator. 1.3 Appearance The EG2030C-M2 appearance is shown in Figure 1-1.
 2  Figure 1-1 EG2030C-M2 Appearance      The EG2030C-M2 interface and button description is given in Table 1-1. Table 1-1 Description of EG2030C-M2 Interface and Button Interface & Button Description Power Switch Power On/Off SIM Support 1.8V/3.0V USIM 2FF RESET Long press over 10 seconds to restore the factory settings LAN 1 RJ45, LAN, 10/100/1000 auto-sensing, auto-MDX  The LED indicators are shown in Figure 1-2. Figure 1-2 LED Indicators of EG2030C-M2   The description of LED indicators are given in Table 1-2.
 3  Table 1-2 LED Indicator Description Identity Description Color Status Description Power Network state  Indicator Blue OFF No Power Supply. Steady On Power on. WLAN SIM card status indicator Yellow Steady On WLAN is on. Blanking WLAN is off. LTE Power Indicator Yellow OFF LTE disconnected. Steady On LTE connected. LTE Signal 3 LTEs, Indicate connection state and signal strength Green All OFF Signal is too weak to attach.   Steady On According to signal strength in turn light up Blanking Scanning the LTE network The CPE is authenticating. CPE is getting IP address from the LTE network.
 4  2. Technical Specifications 2.1 Basic Specification Table 2-1 Basic Specification Item Description LTE Standard 3GPP Release 9 Ethernet LAN Port One RJ-45 port 10/100 auto-sensing, auto-MDX LED Indicators Power/LET Signal/WLAN USIM Support 1.8V/3V 2FF Restore Button Tact Button Long press over 10s to restore the factory settings Power Supply Input: Universal range 100V~240V AC Output: 5VDC, 2A Dimension About   Weight About 400g Color Pantone white C  2.2 RF Specification Table 2-2 RF Specification Item Description LTE Mode TDD LTE Channel Bandwidth 5 MHz /10 MHz /15 MHz /20 MHz MAX Output Power 23±2 dBm LTE Standard 3GPP R9 Frequency Band42: 3400 MHz ~ 3600 MHz Band43: 3600 MHz ~ 3800 MHz LTE Antenna Gain 6 dBi Wifi Standard 802.11b/g/n Frequency 2400MHz~2483.5 MHz Wifi Antenna Gain 5 dBi
 5  2.3 SW Specification Table 2-3 SW Specification Item Description Language Settings English Network Mode Bridge / NAT SIM   PIN Management   SIM Lock Network Connection setup   Create, delete, and edit APNs   Set up dial-up connection automatically   Set up dial-up connection manual LTE Scan Mode   Full Band   Cell Lock   Band / Frequency Preferred VPN   Support VPN pass through   Support L2TP tunnel mode   Support L2 VPN NAT   Port forwarding   Port trigger   DMZ   UPnP Statistics   LAN Link Status   Transmit / Receive traffic   Running Time  2.4 Device Management Table 2-4 Device Management Item Description Maintenance   Date & Time setting   Reset   Restore factory settings   Restore/Backup Configuration File   Local upgrade   FOTA upgrade TR069 Can enable or disable TR069 Management Port mirror Can enable or disable the port mirror function Syslog Support the syslog function can send the log to the PC via LAN Diagnostics Support the Ping and trace route
 6   2.5 Environment Specification Table 2-5 Environment Specification Item Description Operating Temperature -10℃  ~ 40℃ Storage Temperature -20℃  ~ 70℃ Operating Humidity 5% ~ 95%  2.6 Regulatory Compliance FCC Compliance This  device  complies  with  part  15  of  the  FCC  Rules.  Operation  is  subject  to  the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection  against  harmful interference when  the equipment is operated in  a  commercial  environment. This  equipment  generates,  uses, and  can radiate radio frequency energy and, if not installed and used in accordance with the instruction  manual,  may  cause  harmful  interference  to  radio  communications. Operation  of  this  equipment  in  a  residential  area  is  likely  to  cause  harmful interference in which case the user will be required to correct the interference at his own expense. Warning This  equipment  complies  with  FCC  radiation  exposure  limits  set  forth  for  an uncontrolled  environment.  This  equipment  should  be  installed  and  operated  with minimum distance 30cm between the radiator & your body.  ISEDC Compliance This device complies with Innovation, Science, and Economic Development
 7  Canada licence-exempt RSS standard(s).  Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device.  Le présent appareil est conforme aux CNR d' Innovation, Science et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions  suivantes:   (1) l'appareil ne doit pas produire de brouillage, et  (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,  même si le brouillage est susceptible d'en compromettre le fonctionnement.  The antenna(s) used for  this  transmitter must be installed to provide a separation distance of at least 30cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.
 8  3. Configuration Guide 3.1 Log in The EG2030C-M2 manages, configures, and maintains the device by web management page. The steps to log in are as follows: 1.  In the address column of browser, type in http://192.168.150.1, then press “Enter”, login in page is shown in Figure 3-1. Figure 3-1 Login Page   2.  Enter the user name and password, click "LOGIN". After password authentication, you can log on to the web management page. The default user name and password is admin. For security, it is recommended that you open the firewall, and keep your login password, WLAN FTP passwords and password well. 3.2 View Status In  the  overview  area,  you  can  view  the  device  information  and  LTE  status,  such  as Product name, Software version, PLMN, IMSI, RSRP, RSRQ, CINR, SINR, Tx Power, Cell ID, PCI, and so on, as shown in Figure 3-2.
 9  Figure 3-2 View Status   3.3 Basic Configuration 3.3.1 LTE Setting To set the LTE Network, perform the following steps: 1.  Choose LTE.   2.  In the LTE Setting area, configure the LTE network.   3.3.2 Set Connection Method To set the LTE network connection method, perform the following steps: 1.  Choose “LTE>connection Method”, enter the setting connection method page, as shown in Figure 3-3. Figure 3-3 Set Connection Method
 10  2.  In the connection Method area, set the connection method 3.  There are two methods to connect the LTE network, it is needed to choose a method between Auto and Manual, if you want to auto connect to the LET network you should choose the Auto, otherwise you should choose Manual.   4. Click “SAVE & APPLY”.   3.3.3 Set Scan Mode   To set the LTE network scan mode, perform the following steps: 1.  Choose “LTE>Scan Method”, enter the setting scan method page, as shown in Figure 3-4.   Figure 3-4 Set Scan Mode   2.  In the Scan Method area, set the scan mode 3.  You can choose full Band, Frequency Lock, or PCI Lock.   3.3.4 Lock Frequency (Earfcn) To clock the frequency, perform the following steps: 1.  Choose “LTE>Scan Method”.   2.  In the LTE Scan Method area, click Frequency Lock to lock the frequency.   3.  Click ADD LIST, choose a band and frequency, and then click Add to add the band and frequency to the list, as shown in Figure 3-5.
 11  Figure 3-5 Lock Frequency   4. Click “SAVE & APPLY”.   3.3.5 Lock PCI To lock the PCI, perform the following steps: 1.  Choose “LTE>Scan Method”.   2.  In the LTE Scan Method area, click PCI Lock to lock the PCI.   3.  Click ADD LIST you can choose a band, frequency and PCI, then click Add to add the frequency and PCI to the list, as shown in Figure 3-6.
 12  Figure 3-6 Lock Frequency   4. Click “SAVE & APPLY”.
 13  Appendix A  FAQs The POWER indicator does not turn on.   Make sure that the power cable is connected properly and the CPE is powered on.     Make sure that the power adapter is compatible with the CPE.   Fails to Login to the web management page.   Make sure that the CPE is started.     Verify that the CPE is correctly connected to the computer through a network cable. If the problem persists, contact authorized local service suppliers.   The CPE fails to search for the wireless network.   Check that the power adapter is connected properly.     Check that the CPE is placed in an open area that is far away from obstructions, such as concrete or wooden walls.     Check that the CPE is placed far away from household electrical appliances that generate strong electromagnetic field, such as microwave ovens, refrigerators, and satellite dishes.   If the problem persists, contact authorized local service suppliers. The power adapter of the CPE is overheated.   The CPE will be overheated after being used for a long time. Therefore, power off the CPE when you are not using it.     Check that the CPE is properly ventilated and shielded from direct sunlight.   The parameters are restored to default values.   If the CPE powers off unexpectedly while being configured, the parameters may be restored to the default settings.   After configuring the parameters, download the  configuration file to  quickly restore the CPE to the desired settings.
 14  Appendix B  Shipping List The product outward appearance, the color take the material object as, the picture only supply reference.    Index Content Picture Amount 1 EG2030C-M2 CPE with Simple Mounting bracket  1 2 Power adapter  1 3 User Manual  1