User manual
Model: BF-IDM18 Operating Guide RFID Reader Company Addresses Europe, Germany, Headquarter Balluff GmbH Schurwaldstraße 9 D-73765 Neuhausen, Germany Argentina Balluff Argentina S.R.L. Echeverría 1050, 1st UF 2 1604 Buenos Aires - Florida Oeste Australia Balluff Pty Ltd. 18 Malvern Street Bayswater, 3153 Victoria Brasil Balluff Controles Elétricos Ltda. Rua Francisco Foga, 25 ,Distrito Industrial CEP 13280.000 – Vinhedo – SP Canada Balluff Canada Inc. 2840 Argentia Road, Unit 2 Mississauga, Ontario L5N 8G4 China Balluff (Shanghai) Trading Co. Ltd. No.800 Chengshan Rd, 8F, Building A, Yunding International Commercial Plaza 200125, Pudong, Shanghai Japan Balluff Co., Ltd. Aqua Hakusan Bldg. 9F 1-13-7 Hakusan, Bunkyo-ku, Tokyo 113-0001 Mexico Balluff de México S.A. de C.V. Anillo Vial II Fray Junipero Serra No. 4416; Colonia La Vista Residencial CP 76232 Delegación Epigmenio González, Querétaro USA Balluff Inc. 8125 Holton Drive, Florence Kentucky 41042-0937 Model: BF-IDM18 Operating Guide RFID Reader Regulatory Information This device complies with part 15 of the FCC Rules and with Industry Canada’s licenceexempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage; (2) l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Changes or modifications not expressly approved by the party responsible for compliance voids the user's authority to operate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Model: BF-IDM18 Operating Guide RFID Reader Purpose of the Device The BF-IDM18 RFID Reader is intended to read and write ISO15693 / ISO14443 compliant data carriers via magnetic field communication. Variability BF-IDM18 RFID Readers are available in different housings and shapes. Model: BF-IDM18 Operating Guide RFID Reader Connecting the Device BF-IDM18 devices communicate via RS-232 with the controlling unit. RS-232 BIS M Power BIS M Power + RS-232 Power Supply To ensure reliable operation in strong EMC environments it is recommended to connect metal housings or dedicated functional ground pins directly to installations ground. The ground Connection should be short and stable. Depending on the installation situation an indirect ground connection using a RC combination may be required. For further notes concerning the installation of the processor unit please refer to the operating guide of the processor unit. Model: BF-IDM18 Operating Guide RFID Reader Installation notes For proper operation at first a suitable mounting position has to be evaluated. The position should respect the recommended clear zones as described. Furthermore, please note that strong electrical or magnetic fields in the close environment may influence the RFID Reader. Precise information concerning clear zones and distances are available on request. For BF-IDM18 Readers are available in different housings respectively shapes different types of installation may be considered. a) Direct In-Hole mounting (Example): Picture 2: Direct In-Hole mounting (Example) b) Direct On-Wall mounting (Example): Picture 3: Direct On-Wall mounting (Example) Model: BF-IDM18 Operating Guide RFID Reader c) Indirect On-Wall mounting using metal holder (Example): Picture 3: Indirect On-Wall mounting using metal holder (Example): Model: BF-IDM18 Operating Guide RFID Reader Setup and Operation For operation of BF-IDM18 Readers a controlling unit is needed. The BF-IDM18 Readers communicate directly with the controlling unit if it is connected. Status Indicators The device will show its status using the 2 LEDs at the corners of the housing. In normal operation state the meaning of these lights are as follows: ► Green light "Power" indicates that the device is connected to the processor unit and ready to operate. ► Orange light "Tag present" indicates that a RFID tag has been detected in front of the transceiver coil. Electrical Data Operating voltage (nominal) Current draw (at +26,4 V DC) Operating Frequency Active principle Transmit power +19,2…26,4 V DC ≤ 200 mA 13.56 MHz Magnetic field Class 5 Mechanical Data Housing Material Weight max. Ambient temperature Metal / ABS-GF16 / PBT / PA12-GF30 400g 0…+70°C
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Thomas Graf Create Date : 2018:01:24 08:07:03+01:00 Modify Date : 2018:08:21 17:25:53+08:00 Language : de-DE Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Creator : Thomas Graf Creator Tool : Microsoft® Word 2010 Metadata Date : 2018:08:21 17:25:53+08:00 Producer : Microsoft® Word 2010 Document ID : uuid:0efa6d45-7a98-414a-965f-de1d3cf93e74 Instance ID : uuid:f69588c7-b5b2-4558-a64a-81b53b45aed2 Page Count : 7EXIF Metadata provided by EXIF.tools