User manual
Model: BF-IDM21 Operating Guide RFID Reader Company Addresses Europe, Germany, Headquarter Balluff GmbH Schurwaldstraße 9 D-73765 Neuhausen, Germany Argentina Balluff Argentina S.R.L. Echeverría 1050, 1st UF 2 1604 Buenos Aires - Florida Oeste Australia Balluff Pty Ltd. 18 Malvern Street Bayswater, 3153 Victoria Brasil Balluff Controles Elétricos Ltda. Rua Francisco Foga, 25 ,Distrito Industrial CEP 13280.000 – Vinhedo – SP Canada Balluff Canada Inc. 2840 Argentia Road, Unit 2 Mississauga, Ontario L5N 8G4 China Balluff (Shanghai) Trading Co. Ltd. No.800 Chengshan Rd, 8F, Building A, Yunding International Commercial Plaza 200125, Pudong, Shanghai Japan Balluff Co., Ltd. Aqua Hakusan Bldg. 9F 1-13-7 Hakusan, Bunkyo-ku, Tokyo 113-0001 Mexico Balluff de México S.A. de C.V. Anillo Vial II Fray Junipero Serra No. 4416; Colonia La Vista Residencial CP 76232 Delegación Epigmenio González, Querétaro USA Balluff Inc. 8125 Holton Drive, Florence Kentucky 41042-0937 Model: BF-IDM09 21 Operating Guide RFID Reader Regulatory Information This device complies with part 15 of the FCC Rules and with Industry Canada’s licenceexempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage; (2) l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Changes or modifications not expressly approved by the party responsible for compliance voids the user's authority to operate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Model: BF-IDM21 Operating Guide RFID Reader Purpose of the Device The BF-IDM21 RFID Reader is intended to read and write ISO15693 / ISO14443 compliant data carriers via magnetic field communication. Variability BF-IDM21 RFID Readers are available in different housings and shapes. Model: BF-IDM21 Operating Guide RFID Reader Connecting the Device BF-IDM21 devices operate in combination with BIS V processor units when connected to one of the ports labeled with "H1" to "H4". For the connection a shielded standard type 4-wire cable M12 / A-coded is used. 4- wire cable 4- wire cable Picture 1: Example Application To ensure reliable operation in strong EMC environments it is recommended to connect metal housings or dedicated functional ground pins directly to installations ground. The ground connection should be short and stable. Depending on the installation situation an indirect ground connection using a RC combination may be required. For further notes concerning the installation of the processor unit please refer to the operating guide of the processor unit. Model: BF-IDM21 Operating Guide RFID Reader Installation notes For proper operation at first a suitable mounting position has to be evaluated. The position should respect the recommended clear zones as described. Furthermore, please note that strong electrical or magnetic fields in the close environment may influence the RFID Reader. Precise information concerning clear zones and distances are available on request. For BF-IDM21 Readers are available in different housings respectively shapes different types of installation may be considered. a) Direct In-Hole mounting (Example): Picture 2: Direct In-Hole mounting (Example) b) Direct On-Wall mounting (Example): Picture 3: Direct On-Wall mounting (Example) Model: BF-IDM21 Operating Guide RFID Reader c) Indirect On-Wall mounting using metal holder (Example): Picture 3: Indirect On-Wall mounting using metal holder (Example): Model: BF-IDM21 Operating Guide RFID Reader Setup and Operation For operation of BF-IDM21 Readers a BIS V type processor unit is needed. The processor unit is used as gateway between higher level controllers and RFID Reader. Any communication from and to data carriers respectively RFID Readers is managed by the processor unit. Further information concerning the operation or parameterization of RFID Readers can be found operating guide of the processor unit. Status Indicators The device will show its status using the 2 LEDs at the corners of the housing. In normal operation state the meaning of these lights are as follows: ► Green light "Power" indicates that the device is connected to the processor unit and ready to operate. ► Orange light "Tag present" indicates that a RFID tag has been detected in front of the transceiver coil. Electrical Data Operating voltage (nominal) Current draw (at +24 V DC) Operating Frequency Active principle Maximum transmit power +24 V DC ≤ 200 mA 13.56 MHz Magnetic field 1W Mechanical Data Housing Material Weight max. Ambient temperature Metal / ABS-GF16 / PBT / PA12-GF30 400g 0…+70°C
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Thomas Graf Create Date : 2018:08:21 09:03:20Z Modify Date : 2018:08:21 17:26:07+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Creator Tool : Microsoft® Word 2016 Metadata Date : 2018:08:21 17:26:07+08:00 Producer : Mac OS X 10.13.6 Quartz PDFContext Format : application/pdf Creator : Thomas Graf Document ID : uuid:144F92BB-FC51-4E69-B1C0-26CF5A77B5ED Instance ID : uuid:ebecd283-45d3-4956-8318-f893530cdcdf Page Count : 7EXIF Metadata provided by EXIF.tools