Balluff BFIDU01 RFID Reader User Manual BF IDU01 Manual v 03

Balluff GmbH RFID Reader BF IDU01 Manual v 03

Users Manual

Download: Balluff BFIDU01 RFID Reader User Manual BF IDU01 Manual  v 03
Mirror Download [FCC.gov]Balluff BFIDU01 RFID Reader User Manual BF IDU01 Manual  v 03
Document ID2910982
Application IDPahj0cUBU7HddoD9ZYcNbw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize27.6kB (344997 bits)
Date Submitted2016-02-25 00:00:00
Date Available2016-08-23 00:00:00
Creation Date2015-10-12 17:26:24
Producing SoftwareGPL Ghostscript 9.0
Document Lastmod2016-02-09 00:20:12
Document TitleBF-IDU01_Manual__v_03
Document CreatorPDFCreator Version 1.2.0
Document Author: GRAFT

BF-IDU01
BF-IDU01
RFID-Reader
RFID-Reader
Company Addresses
Europe, Germany, Headquarter
Balluff GmbH
Schurwaldstraße 9
D-73765 Neuhausen, Germany
Argentina
Balluff Argentina S.R.L.
Echeverría 1050, 1st UF 2
1604 Buenos Aires - Florida Oeste
Australia
Balluff Pty Ltd.
18 Malvern Street
Bayswater, 3153 Victoria
Brasil
Balluff Controles Elétricos Ltda.
Rua Francisco Foga, 25 ,Distrito Industrial
CEP 13280.000 – Vinhedo – SP
Canada
Balluff Canada Inc.
2840 Argentia Road, Unit 2 Mississauga,
Ontario L5N 8G4
China
Balluff (Shanghai) Trading Co. Ltd.
No.800 Chengshan Rd, 8F, Building A, Yunding International Commercial Plaza
200125, Pudong, Shanghai
Japan
Balluff Co., Ltd.
Aqua Hakusan Bldg. 9F 1-13-7 Hakusan, Bunkyo-ku,
Tokyo 113-0001
Mexico
Balluff de México S.A. de C.V.
Anillo Vial II Fray Junipero Serra No. 4416; Colonia La Vista Residencial
CP 76232 Delegación Epigmenio González, Querétaro
USA
Balluff Inc.
8125 Holton Drive, Florence
Kentucky 41042-0937
Operating Guide
Purpose of the Device
The BF-IDU01 device is intended to read and write "EPC Global Class 1 Gen2" compliant data
carriers (so called tags) via country dependent UHF radio frequencies.
Check that you have the right device variant
This UHF system consists of a radio frequency unit and an integrated antenna according to
specifications and may only be operated within the specified countries subject to all applicable
national legal regulations and standards.
Check that the type label contains the correct type approval symbol for your country.
► When using the UHF system in the European Community, the provisions in ETSI standard 302 208
apply.
► When using the UHF system in the USA, the directives of the FCC, Part 15 B and 15 C, apply.
► When using the UHF system in Canada, the directives of the IC, RSS-210 apply.
► When using the UHF system in Mexico, the directives of the SCT, NOM-121-SCT1-2009 apply.
► When using the UHF system in Argentina, the directives of Resolución SC 729/80 and SC 784/87
apply.
► When using the UHF system in Brazil, the directives of the ANATEL, 506/2008 and 442/2006 apply.
► When using the UHF system in China, the directives of the RFID National Standard and GB 9254
apply.
► When using the UHF system in Japan, the directives of "Radio Law" and ARIB T106 apply.
► When using the UHF system in Australia, the directives of the Radiocommunications Class License
2000 (Item 32A) apply.
BF-IDU01
BF-IDU01
RFID-Reader
RFID-Reader
Connecting the Device
Setup and Operation
The device has to be connected to one of the head connectors "H1" .. "H4" of a Balluff BIS V
control unit via standard 4-wire cable with M12 industry connectors. The control unit delivers
power supply and controls the device over this connection.
The BF-IDU01 device will operate when the BIS V control unit receives read or write commands
from the connected PLC. See the manual of BIS V control units for how to send commands to
the control unit.
Make an additional ground connection to the Functional Ground terminal (Symbol
directly or using an RC combination to ground.
The transmission power may be set up with Service Software e.g. "Balluff UHF Manager" up to
the specified maximum to control the read and write range of the device.
) either
Status Indicators
The device will show its status using the 4 LEDs at the corners of the housing. In normal
operation state the meaning of these lights are as follows:
► Green light "Power" indicates that the device is connected to the control unit and ready to
operate.
► Red light "Status" (permanent) indicates that the device's temperature is outside limits,
probably because the ambient temperature is too high or the device is defective.
► Red light "Status" (flashing) indicates that the devices settings are not initialized correctly.
Please contact Service.
The control unit itself needs to be connected to a power supply and the customer's PLC unit.
See the BIS V manual for details.
► Blue light "RF active" indicates that the device has turned radio frequency transmission on
and tries to scan for tags or write or read data over the air.
► Orange light "Tag present" indicates that at least one UHF EPC Global tag could be found by
Mounting
the device. The light will stay on for at least 3 seconds after a successful scan.
Before operating, the device has to be fixed mounted with at least 2 screws of M4 or M5 size in
mounting holes at back side (see image).
The BF-IDU01 device may be mounted in any direction, the operating direction of the integrated
antenna is towards the front containing the "BIS VU Identification Systems" label.
Optional mounting plates are available for installing the device.
Electrical Data
The antennas of the identification system BIS U transmit ultra-high frequency electromagnetic
waves. People should not remain within close range of the UHF antenna for long periods
(several hours). When selecting the installation position for the BF-IDU01 device, make sure
that the minimum distance between the UHF antenna and the workplace is 25 cm.
Operating voltage Vs
Current draw (at 24 V DC)
ETSI-Version:
Operating Frequency
Maximum Transmit Power
FCC/IC-Version (also Argentina, Mexico):
Operating Frequency
Maximum Transmit Power
Brazil Version:
Operating Frequency
Maximum Transmit Power
China Version:
Operating Frequency
Maximum Transmit Power
Japan Version:
Operating Frequency
Maximum Transmit Power
Australia Version:
Operating Frequency
Maximum Transmit Power
Maximum Read Range
Antenna Beam Opening Angle
Antenna Polarization
19.2…28.8 V DC
≤ 200 mA
865.0 .. 868.0 MHz
25 dBm (320 mW) ERP
902 .. 928 MHz
27 dBm (0,5 W) EIRP
915 .. 928 MHz
27 dBm (0,5 W) EIRP
920.5 .. 924.5 MHz
25 dBm (320 mW) ERP
916.7 .. 920.5 MHz
27 dBm (0,5 W) EIRP
920 .. 926 MHz
27 dBm (0,5 W) EIRP
1000 mm
90° (horizontal/vertical )
Circular LH
Mechanical Data
Housing material
Metal / ABS / PC
Class B: (Section 15.105)
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
‐Reorient or relocate the receiving antenna.
‐Increase the separation between the equipment and receiver.
‐Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
‐Consult the dealer or an experienced radio/ TV technician for help.
(Section 15.21)
CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the user's
authority to operate the equipment.
RF exposure warning
This equipment must be installed and operated in accordance with provided instructions and the
antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm
from all persons and must not be co‐located or operating in conjunction with any other antenna or
transmitter. End‐users and installers must be provide with antenna installation instructions and
transmitter operating conditions for satisfying RF exposure compliance.
For IC:
Canada, Industry Canada (IC) Notices
This device complies with Canada licence‐exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Canada, avis d'Industry Canada (IC)
Cet appareil est conforme avec Industrie Canada exemptes de licence RSS standard(s).
Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne
doit pas causer d'interférence et (2) cet appareil doit accepter toute interférence,
notamment les interférences qui peuvent affecter son fonctionnement.
Radio Frequency (RF) Exposure Information
The radiated output power of the Wireless Device is below the Industry Canada (IC) radio frequency
exposure limits. The Wireless Device should be used in such a manner such that the potential for
human contact during normal operation is minimized.
This device has also been evaluated and shown compliant with the IC RF Exposure limits under
mobile exposure conditions. (antennas are greater than 20cm from a person's body).
Informations concernant l'exposition aux fréquences radio (RF)
La puissance de sortie émise par l’appareil de sans fil est inférieure à la limite d'exposition aux
fréquences radio d'Industry Canada (IC). Utilisez l’appareil de sans fil de façon à minimiser les
contacts humains lors du fonctionnement normal.
Ce périphérique a également été évalué et démontré conforme aux limites d'exposition aux RF
d'IC dans des conditions d'exposition à des appareils mobiles (antennes sont supérieures à 20 cm à
partir du corps d'une personne).

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : GRAFT
Create Date                     : 2015:10:12 17:26:24+02:00
Modify Date                     : 2016:02:09 00:20:12+08:00
Subject                         : 
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Producer                        : GPL Ghostscript  9.0
Keywords                        : 
Creator Tool                    : PDFCreator Version 1.2.0
Metadata Date                   : 2016:02:09 00:20:12+08:00
Document ID                     : 1ed1fbab-7351-11e5-0000-766aaff27fff
Instance ID                     : uuid:802b16c2-6ce9-48c6-9b96-84dbecb4c3d0
Format                          : application/pdf
Title                           : BF-IDU01_Manual__v_03
Creator                         : GRAFT
Description                     : 
Description (x-repair)          : 
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AGZY-BFIDU01

Navigation menu