Balluff BFIDU01 RFID Reader User Manual BF IDU01 Manual v 03
Balluff GmbH RFID Reader BF IDU01 Manual v 03
Balluff >
Users Manual
BF-IDU01 BF-IDU01 RFID-Reader RFID-Reader Company Addresses Europe, Germany, Headquarter Balluff GmbH Schurwaldstraße 9 D-73765 Neuhausen, Germany Argentina Balluff Argentina S.R.L. Echeverría 1050, 1st UF 2 1604 Buenos Aires - Florida Oeste Australia Balluff Pty Ltd. 18 Malvern Street Bayswater, 3153 Victoria Brasil Balluff Controles Elétricos Ltda. Rua Francisco Foga, 25 ,Distrito Industrial CEP 13280.000 – Vinhedo – SP Canada Balluff Canada Inc. 2840 Argentia Road, Unit 2 Mississauga, Ontario L5N 8G4 China Balluff (Shanghai) Trading Co. Ltd. No.800 Chengshan Rd, 8F, Building A, Yunding International Commercial Plaza 200125, Pudong, Shanghai Japan Balluff Co., Ltd. Aqua Hakusan Bldg. 9F 1-13-7 Hakusan, Bunkyo-ku, Tokyo 113-0001 Mexico Balluff de México S.A. de C.V. Anillo Vial II Fray Junipero Serra No. 4416; Colonia La Vista Residencial CP 76232 Delegación Epigmenio González, Querétaro USA Balluff Inc. 8125 Holton Drive, Florence Kentucky 41042-0937 Operating Guide Purpose of the Device The BF-IDU01 device is intended to read and write "EPC Global Class 1 Gen2" compliant data carriers (so called tags) via country dependent UHF radio frequencies. Check that you have the right device variant This UHF system consists of a radio frequency unit and an integrated antenna according to specifications and may only be operated within the specified countries subject to all applicable national legal regulations and standards. Check that the type label contains the correct type approval symbol for your country. ► When using the UHF system in the European Community, the provisions in ETSI standard 302 208 apply. ► When using the UHF system in the USA, the directives of the FCC, Part 15 B and 15 C, apply. ► When using the UHF system in Canada, the directives of the IC, RSS-210 apply. ► When using the UHF system in Mexico, the directives of the SCT, NOM-121-SCT1-2009 apply. ► When using the UHF system in Argentina, the directives of Resolución SC 729/80 and SC 784/87 apply. ► When using the UHF system in Brazil, the directives of the ANATEL, 506/2008 and 442/2006 apply. ► When using the UHF system in China, the directives of the RFID National Standard and GB 9254 apply. ► When using the UHF system in Japan, the directives of "Radio Law" and ARIB T106 apply. ► When using the UHF system in Australia, the directives of the Radiocommunications Class License 2000 (Item 32A) apply. BF-IDU01 BF-IDU01 RFID-Reader RFID-Reader Connecting the Device Setup and Operation The device has to be connected to one of the head connectors "H1" .. "H4" of a Balluff BIS V control unit via standard 4-wire cable with M12 industry connectors. The control unit delivers power supply and controls the device over this connection. The BF-IDU01 device will operate when the BIS V control unit receives read or write commands from the connected PLC. See the manual of BIS V control units for how to send commands to the control unit. Make an additional ground connection to the Functional Ground terminal (Symbol directly or using an RC combination to ground. The transmission power may be set up with Service Software e.g. "Balluff UHF Manager" up to the specified maximum to control the read and write range of the device. ) either Status Indicators The device will show its status using the 4 LEDs at the corners of the housing. In normal operation state the meaning of these lights are as follows: ► Green light "Power" indicates that the device is connected to the control unit and ready to operate. ► Red light "Status" (permanent) indicates that the device's temperature is outside limits, probably because the ambient temperature is too high or the device is defective. ► Red light "Status" (flashing) indicates that the devices settings are not initialized correctly. Please contact Service. The control unit itself needs to be connected to a power supply and the customer's PLC unit. See the BIS V manual for details. ► Blue light "RF active" indicates that the device has turned radio frequency transmission on and tries to scan for tags or write or read data over the air. ► Orange light "Tag present" indicates that at least one UHF EPC Global tag could be found by Mounting the device. The light will stay on for at least 3 seconds after a successful scan. Before operating, the device has to be fixed mounted with at least 2 screws of M4 or M5 size in mounting holes at back side (see image). The BF-IDU01 device may be mounted in any direction, the operating direction of the integrated antenna is towards the front containing the "BIS VU Identification Systems" label. Optional mounting plates are available for installing the device. Electrical Data The antennas of the identification system BIS U transmit ultra-high frequency electromagnetic waves. People should not remain within close range of the UHF antenna for long periods (several hours). When selecting the installation position for the BF-IDU01 device, make sure that the minimum distance between the UHF antenna and the workplace is 25 cm. Operating voltage Vs Current draw (at 24 V DC) ETSI-Version: Operating Frequency Maximum Transmit Power FCC/IC-Version (also Argentina, Mexico): Operating Frequency Maximum Transmit Power Brazil Version: Operating Frequency Maximum Transmit Power China Version: Operating Frequency Maximum Transmit Power Japan Version: Operating Frequency Maximum Transmit Power Australia Version: Operating Frequency Maximum Transmit Power Maximum Read Range Antenna Beam Opening Angle Antenna Polarization 19.2…28.8 V DC ≤ 200 mA 865.0 .. 868.0 MHz 25 dBm (320 mW) ERP 902 .. 928 MHz 27 dBm (0,5 W) EIRP 915 .. 928 MHz 27 dBm (0,5 W) EIRP 920.5 .. 924.5 MHz 25 dBm (320 mW) ERP 916.7 .. 920.5 MHz 27 dBm (0,5 W) EIRP 920 .. 926 MHz 27 dBm (0,5 W) EIRP 1000 mm 90° (horizontal/vertical ) Circular LH Mechanical Data Housing material Metal / ABS / PC Class B: (Section 15.105) FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ‐Reorient or relocate the receiving antenna. ‐Increase the separation between the equipment and receiver. ‐Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ‐Consult the dealer or an experienced radio/ TV technician for help. (Section 15.21) CAUTION: Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. RF exposure warning This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co‐located or operating in conjunction with any other antenna or transmitter. End‐users and installers must be provide with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. For IC: Canada, Industry Canada (IC) Notices This device complies with Canada licence‐exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Canada, avis d'Industry Canada (IC) Cet appareil est conforme avec Industrie Canada exemptes de licence RSS standard(s). Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer d'interférence et (2) cet appareil doit accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement. Radio Frequency (RF) Exposure Information The radiated output power of the Wireless Device is below the Industry Canada (IC) radio frequency exposure limits. The Wireless Device should be used in such a manner such that the potential for human contact during normal operation is minimized. This device has also been evaluated and shown compliant with the IC RF Exposure limits under mobile exposure conditions. (antennas are greater than 20cm from a person's body). Informations concernant l'exposition aux fréquences radio (RF) La puissance de sortie émise par l’appareil de sans fil est inférieure à la limite d'exposition aux fréquences radio d'Industry Canada (IC). Utilisez l’appareil de sans fil de façon à minimiser les contacts humains lors du fonctionnement normal. Ce périphérique a également été évalué et démontré conforme aux limites d'exposition aux RF d'IC dans des conditions d'exposition à des appareils mobiles (antennes sont supérieures à 20 cm à partir du corps d'une personne).
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : GRAFT Create Date : 2015:10:12 17:26:24+02:00 Modify Date : 2016:02:09 00:20:12+08:00 Subject : XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Producer : GPL Ghostscript 9.0 Keywords : Creator Tool : PDFCreator Version 1.2.0 Metadata Date : 2016:02:09 00:20:12+08:00 Document ID : 1ed1fbab-7351-11e5-0000-766aaff27fff Instance ID : uuid:802b16c2-6ce9-48c6-9b96-84dbecb4c3d0 Format : application/pdf Title : BF-IDU01_Manual__v_03 Creator : GRAFT Description : Description (x-repair) : Page Count : 4EXIF Metadata provided by EXIF.tools