Baltech 1056200101A02C Tag Reader User Manual ACCESS45 5 232 LEGP LB Operation Manual

Baltech AG Tag Reader ACCESS45 5 232 LEGP LB Operation Manual

User Manual

Download: Baltech 1056200101A02C Tag Reader User Manual ACCESS45 5 232 LEGP LB Operation Manual
Mirror Download [FCC.gov]Baltech 1056200101A02C Tag Reader User Manual ACCESS45 5 232 LEGP LB Operation Manual
Document ID1112366
Application IDmv3WX4g6ORR+yqQmimEZ/g==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize9.03kB (112859 bits)
Date Submitted2009-05-19 00:00:00
Date Available2009-05-19 00:00:00
Creation Date2009-01-07 09:41:25
Producing SoftwareOpenOffice.org 2.1
Document Lastmod0000-00-00 00:00:00
Document TitleACCESS45-5-232-LEGP-LB Operation Manual
Document CreatorWriter
Document Author: juergen roesch

Operation Manual
10562-02-001 /Y591-EIND-101
REVISION 1.0, 2009-01-07
The Y591-EIND-101 is a RFID Read-/Write-Device (short: reader). The reader supports
Hitag© family tags and Indala cards. It provides a serial interface RS232 to output or
exchange data with a host computer (typically an Equitrac Page Counter Unit, a printer or a
copy machine) and a 125kHz inductive interface to supply power to and exchange data with
the tags. The host computer can control a bi-colour LED and a beeper to interface with the
user.
Mounting and Connection
The reader generates a magnetic field with the frequency of 125kHz which is influenced by
any electrically conductive material in close proximity to the device. When mounting the unit,
a distance to any such material of minimum 10 cm is required to ensure that there will be no
significant degradation of the performance in terms of read range and reliability. Mounting
the unit directly to metal would result in a severe reduction of read range down to zero
functionality. Care should be taken when testing the device after mounting at a problematic
environment: Read ranges and performance vary from card to card and very much from card
to tag or key-fob.
When mounting multiple readers, the distance between readers should be minimum 0.5 m in
order to avoid degradation of performance due to interference.
To connect the device to an Equitrac PageCounter, printer or copy machine, please make sure
the host system provides an 14-pin Mini-DIN socket intended for connection of the reader.
Operation
Whenever the device is connected to a proper power supply, it will switch on the internal
antenna and periodically scan for a card. Once a card has been detected, the card number is
read, the data converted and sent to the host system through the serial interface. To enable the
device to read cards, tags and key-fobs successfully, they should be placed centred above the
reader.
Technical Data
DC Electrical Characteristics
Symbol
Vdd
Idd
Idd1
Parameter
Supply Voltage
Supply current
Peak Supply
current
Condition
Inrush
Min Typ Max
4.75 5
5.25
250
450
Units
VDC
mA
mA
Additional requirements for the supply voltage: Vripple = 50mVpp max.
RF Characteristics
Operating frequency: 125kHz
Data transmission modulation reader to card: AM
Data transmission modulation card to reader: ASK and PSK
Pinout RS422-Interface MDR 14-Pole connector plug and Signal
Descriptions
Pin
10
11
12
13
14
Name
GND
-TX RS422
+TX RS422
-RX RS422
+RX RS422
+5V Power
+5V Return
Type
Power
Output
Output
Input
Input
Power
Power
I/O
Description
Signal and Power Ground
RS422-data from reader
RS422-data from reader
Not connected
RS422-data to reader
RS422-data to reader
Not connected
Signal and Power Ground
Not connected
Power Ground
Not connected
Connected
Not connected
Not connected
Temperature
Operating temperature range: 0…45°C
Storage temperature range: -20…+60°C
Thermal shock: 30°C/min maximum dT/dt
Humidity
Operating: 20% to 80% relative humidity; non condensing
Non-operating: 10% to 90% relative humidity; non condensing
FCC:
Any changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Canada:
This Class B digital apparatus complies with Canadian ICES-003.Cet appareil numérique de
la classe B est conforme à la norme NMB-003 du Canada

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 3
Title                           : ACCESS45-5-232-LEGP-LB Operation Manual
Author                          : juergen roesch
Creator                         : Writer
Producer                        : OpenOffice.org 2.1
Create Date                     : 2009:01:07 09:41:25+01:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OKY1056200101A02C

Navigation menu