Banner Engineering Q120RAUS R-Gage Radar Sensors User Manual
Banner Engineering Corporation R-Gage Radar Sensors
User Manual
Rhein Tech Laboratories, Inc. 360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com Appendix H: Client: Banner Engineering, Inc. Model: Q120RA-US Standard: FCC 15.245 FCC ID: UE3Q120RAUS Report #: 2012355 Manual Please refer to the following pages. Page 21 of 27 R-GAGE™ Q120RA-AF2 Sensor Radar-Based Dual-Zone Narrow-Beam Sensors for Detection of Moving and Stationary Targets For complete technical information about this product, including dimensions, accessories, and specifications, see www.BannerEngineering.com and search 157494_web CAUTION: Make No Modifications to this Product Any modifications to this product not expressly approved by Banner Engineering could void the user's authority to operate the product. Contact the Factory for more information. WARNING: Not To Be Used for Personnel Protection Never use this product as a sensing device for personnel protection. Doing so could lead to serious injury or death. This product does NOT include the selfchecking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Model Sensing Range Q120RA-US-AF2 Two independent sensing zones; 1 to 40+ meters (131 ft) Q120RA-EU-AF2 Q120RA-UK-AF2 Connection Supply Voltage Telecom Approval Output Pending approval for United States 5-wire 2 m (6.5 ft) Integral cable 12 to 30V dc Pending approval for Europe (except UK) and China DIP-switch-selectable NPN or PNP; N.O. or N.C. Pending approval for UK Cabled models only are listed. For integral 5-pin Euro-style (M12) quick-disconnect fitting, add suffix "Q" to the model number (e.g., Q120RA-xx-AF2Q). *QD models require a mating cordset. Sensor Configuration The sensitivity, and output configuration can be selected via the DIP switches on the side of the sensor. Use the included spanner to open the screw-off cover on the side of the sensor and access the DIP switches. Important: Tighten the DIP switch cover a full quarter turn after contact to maintain the watertight seal. DIP Switch Functions Switches Function A1, A2, A3, A4 Zone 1 Distance (detects objects from sensor face to this point) A5, A6, A7 Zone 2 Distance, Offset from Zone 1 A8 Polarity B1, B2, B3 Sensitivity (higher sensitivity sees weaker objects and has a larger beam pattern) B4, B5, B6 Response Speed B7 Normally Open/Normally Closed output functionality B8 Not Used DIP switch 1 is on the left and DIP switch 8 is on the right. P/N 157494 Rev. C 8/21/2012 0 157494 R-GAGE™ Q120RA-AF2 Sensor Distance Settings * Default settings Zone 1 Distance A1 A2 A3 A4 Distance EU US, UK 2 m (6.6 ft) 3.5 m (11.5 ft) 2.5 m (8.2 ft) 4 m (13.1 ft) 3 m (9.8 ft) 4.5 m (14.8 ft) 3.5 m (11.5 ft) 5 m (16.4 ft) 4 m (13.1 ft) 5.5 m (18.0 ft) 5 m (16.4 ft) 6 m (19.7 ft) 6 m (19.7 ft) 6.5 m (21.3 ft) 7 m (23.0 ft) 7 m (23.0 ft) 1* 0* 0* 0* 8 m (26.2 ft) 8 m (26.2 ft) 10 m (32.8 ft) 10 m (32.8 ft) 12 m (39.4 ft) 12 m (39.4 ft) 14 m (45.9 ft) 14 m (45.9 ft) 16 m (52.5 ft) 16 m (52.5 ft) 20 m (65.6 ft) 20 m (65.6 ft) 25 m (82.0 ft) 25 m (82.0 ft) 30 m (98.4 ft) 30 m (98.4 ft) Zone 2 Distance Offset from Zone 1 A5 A6 A7 Offset 2 m (6.6 ft) 4 m (13.1 ft) 6 m (19.7 ft) 0* 1* 1* 8 m (26.2 ft) 10 m (32.8 ft) 15 m (49.2 ft) 20 m (65.6 ft) 25 m (82.0 ft) NOTE: Highest sensitivity is achieved only if the sensing distance is 36 m (118.1 ft) or less. www.bannerengineering.com - tel: 763-544-3164 P/N 157494 Rev. C R-GAGE™ Q120RA-AF2 Sensor Sensitivity Selection * Default settings B1 B2 B3 Sensitivity 0* 0* 0* 8 (Highest) 7... 6 (High) 5... 4 (Medium) 3... 2 (Low) 1 (Lowest) NOTE: Operation at a high sensitivity not guaranteed for a zone set beyond 45 m (147.6 ft) Response Speed * Default settings B4 B5 B6 ON Total OFF Total Total 15 15 30 30 70 100 30 120 150 0* 1* 1* 50 300 350 50 600 650 30 1000 1030 120 600 720 120 6000 6120 Output Configuration * Default settings A8 NPN / PNP B7 Normally Open / Closed 0* NPN 0* NO PNP NC P/N 157494 Rev. C www.bannerengineering.com - tel: 763-544-3164 R-GAGE™ Q120RA-AF2 Sensor Specifications Range The sensor is able to detect a proper object (see Detectable Objects) from 1 to 40+ m (3.3 to 131.2+ ft), depending on target Detectable Objects Objects containing metal, water, or similar high-dielectric materials Operating Principle Frequency modulated continuous-wave (FMCW) radar Operating Frequency 24.00 to 24.25 GHz, ISM Band (varies slightly with model, depending on national telecom regulations) Supply Voltage 12 to 30V dc, less than 100 mA, exclusive of load Supply Protection Circuitry Protected against reverse polarity and transient overvoltages Indicators Power LED: Green (power ON) Signal Strength LED: Red, flashes in proportion to signal strength. Steady on at 4x excess gain. Only indicates signal amplitude, not target distance. Output LEDs: Yellow (output energized) / Red (configuration) Adjustments DIP-switch-configurable sensing distance, sensitivity, response time, and output configuration Construction Housing: ABS/polycarbonate Lightpipes: Acrylic Access Cap: Polyester Operating Temperature – 40° to + 65° C (– 40° to + 149° F) Delay at Power-up Less than 2 seconds Output Configuration DIP-Switch A8 selects Dual NPN (default) or PNP; DIP-Switch B7 selects N.O. (default) or N.C. operation; 150mA each • Zone 1 output: white wire • Zone 2 output: black wire Environmental Rating IP67 Connections Integral 5-wire 2 m (6.5 ft) cable or M12 Euro-style QD fitting. QD models require a mating cordset Certifications Telecom approvals pending Output Protection Protected against short circuit conditions Response Time DIP-Switch-configurable ON/OFF response time FCC ID: UE3Q120RAUS—This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Windows The R-GAGE sensor can be placed behind a glass or a plastic window, but the configuration must be tested and the distance from the sensor to the window must be determined and controlled prior to installation. There is typically a 20% signal reduction when the sensor is placed behind a window. Polycarbonate at 4mm thickness performs well in most situations, but the performance depends on filler materials. Thinner (1 to 3 mm) windows have high reflection. The amount of reflection depends on the material, thickness, and distance from the sensor to the window. Locate the sensor in a position of minimum reflection from the window, which will repeat every 6.1 mm of distance between the sensor and the window. The positions of maximum reflection from the window repeat between the minimums, and decrease in effect until the window is approximately 150 mm (5.9 in) away. Consult the factory for pre-tested window materials which can be used at any distance without issue. Additionally, the face of the window should be protected from flowing water and ice by use of a flow diverter or hood directly above the window. Falling rain or snow in the air in front of the window, light water mist, or small beads on the face of the window are typically not an issue. However, a thick, continuous surface of water or ice directly on the face of the window can be detected as a dielectric boundary. Hookup Wiring Key: 12-30V dc – 1 = Brown 2 = White 3 = Blue Load 1 4 = Black Load 2 5 = Gray (Do not connect) shield (QD cordset) NOTE: Banner recommends that the shield wire (QD cordsets only) be connected to earth ground or dc common. Shielded cordsets are recommended for all QD models. www.bannerengineering.com - tel: 763-544-3164 P/N 157494 Rev. C R-GAGE™ Q120RA-AF2 Sensor Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Rick McMurray Create Date : 2013:01:23 12:11:22-07:00 Modify Date : 2013:01:23 12:11:41-07:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2013:01:23 12:11:41-07:00 Creator Tool : Acrobat PDFMaker 9.1 for Word Format : application/pdf Creator : Rick McMurray Document ID : uuid:82033618-bbcb-4b65-8150-ff34a08e798f Instance ID : uuid:3d29a6fd-8844-4ff2-9f77-69364e8ab50c Producer : Adobe PDF Library 9.0 Page Count : 6 For : Janelle Blewett, Title : 157494_FCC.pdf Bounding Box : 56 30 553 752 Container Version : 11 Creator Version : 16 Image Height : 722 Image Width : 497 Image Size : 497x722 Megapixels : 0.359EXIF Metadata provided by EXIF.tools