Barco N V JAO1501 Panel PC User Manual 106B3A63

Barco N.V. Panel PC 106B3A63

Contents

Users Manual

BARCO LTD. 33F., No. 16 &No.16-1, Xizhan Rd., Banqiao Dist., New Taipei City 220, Taiwan (R.O.C.) Telephone: +886-2-7715-0299    Fax: +886-2-7715-0298     BARCO Panel PC  JAO15/ JAO18 User Manual   Version: 1.2
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   CCCContent Preface ........................................................................................................... 3 Copyright ................................................................................................ 3 Disclaimer .............................................................................................. 3 Acknowledgements ............................................................................... 3 Regulatory Compliance Statements....................................................... 3 Declaration of Conformity ..................................................................... 3 RoHS Compliance ........................................................................................... 4 Safety Precautions ......................................................................................... 6 Technical Support and Assistance .................................................................. 7 Conventions Used in this Manual .................................................................. 7 Ordering Information ................................................................................... 10 Chapter 1: Product Introduction .................................................................. 11 JAO15 ................................................................................................... 11 JAO18 ................................................................................................... 14 IO introduction ............................................................................................. 17 Mechanical Dimensions ............................................................................... 19 JAO15 ................................................................................................... 19 JAO18 ................................................................................................... 19 Chapter2: Jumpers and Connectors ............................................................. 20 Before you Begin .................................................................................. 20 Jumper Setting ..................................................................................... 21 Locations of the Jumpers and Connectors ................................................... 22 Top View ............................................................................................... 22 Jumpers and DIP Switch Setting ................................................................... 22 CMOS Clear Select ................................................................................ 22 Connector Pin Definition .............................................................................. 23 External I/O Interface ........................................................................... 23 19V DC Power Input ..................................................................... 23 REAR IO USB PORT ....................................................................... 23 Service Call connector .................................................................. 24 Line-out Jack ................................................................................. 25 Internal Connectors .............................................................................. 26 SATA .............................................................................................. 26 Mini-PCIe Slot ............................................................................... 27 Block Diagram .......................................................... 錯誤錯誤錯誤錯誤!  尚未定義書籤尚未定義書籤尚未定義書籤尚未定義書籤。。。。 Chapter 3: System Setup ...................................................................... 28 Replace SATA Disk ................................................................................. 28 Replace RAM ........................................................................................ 28 Install Handset .................................................. 錯誤錯誤錯誤錯誤!  尚未定義書籤尚未定義書籤尚未定義書籤尚未定義書籤。。。。
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Preface Copyright This publication, including all photographs, illustrations and software, is protected under international copyright laws, with all rights reserved. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written consent from BARCO. Disclaimer The information in this document is subject to change without prior notice and does not represent commitment from BARCO International Co., Ltd. However, users may update their knowledge of any product in use by constantly checking its manual posted on our website: http://www.barco.com. BARCO shall not be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of any product, nor for any infringements upon the rights of third parties, which may result from such use. Any implied warranties of merchantability or fitness for any particular purpose is also disclaimed.   Acknowledgements ST156B/ST185D is a trademark of BARCO. All other product names mentioned herein are registered trademarks of their respective owners. Regulatory Compliance Statements This section provides the FCC compliance statement for Class A devices and describes how to keep the system CE compliant. Declaration of Conformity FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the  following  two  conditions:  (1)  This  device  may  not  cause  harmful interference,  and  (2)  this  device  must  accept  any  interference  received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the  FCC Rules.    These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio  frequency  energy and,  if  not  installed  and  used  in  accordance  with the instructions, may cause harmful interference to radio communications.
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   However,  there  is  no  guarantee  that  interference  will  not  occur  in  a particular installation.    If this equipment does cause harmful interference to  radio or  television  reception,  which  can  be  determined by  turning  the equipment  off  and  on,  the  user  is  encouraged  to  try  to  correct  the interference by one of the following measures:   Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help. . FCC Caution:  Any  changes  or  modifications  not  expressly  approved  by  the  party responsible for compliance could void the user's authority to operate this equipment.  This  transmitter  must  not  be  co-located  or  operating  in  conjunction with any other antenna or transmitter.  Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled  environment.  This  equipment  should  be  installed  and operated with minimum distance 20cm between the radiator & your body.  CE The product(s) described in this manual complies with all applicable European Union (CE) directives if it has a CE marking. For computer systems to remain CE compliant, only CE-compliant parts may be used. Maintaining CE compliance also requires proper cable and cabling techniques.  IEC/ISO All components and wirings comply with IEC or ISO standard, except for Plastic Enclosure is UL approved only RoHS Compliance BARCO RoHS Environmental Policy and Status Update This publication, including all photographs, illustrations and software, is protected under international copyright laws, with all rights reserved. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written consent from BARCO. RoHS restricts the use of Lead (Pb) < 0.1% or 1,000ppm, Mercury (Hg) < 0.1% or 1,000ppm, Cadmium (Cd) < 0.01% or 100ppm, Hexavalent Chromium (Cr6+) < 0.1% or 1,000ppm, Polybrominated biphenyls (PBB) < 0.1% or 1,000ppm, and Polybrominated diphenyl Ethers (PBDE) < 0.1% or 1,000ppm. In order to meet the RoHS compliant directives, BARCO has established an engineering and manufacturing task force to implement the introduction of green products. The task force will ensure that we follow the standard
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry quality levels for which BARCO are renowned. The model selection criteria will be based on market demand. Vendors and suppliers will ensure that all designed components will be RoHS compliant.
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Safety Precautions 1. Read these safety instructions carefully. 2. Keep this User Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6. Put this equipment on a stable surface during installation. Dropping it or letting it fall may cause damage. 7. The openings on the enclosure are for air convection to protect the equipment from overheating. DO NOT COVER THE OPENINGS. 8. Make sure the voltage of the power source is correct before connecting the equipment to the power outlet. 9. Place the power cord in a way so that people will not step on it. Do not place anything on top of the power cord. Use a power cord that has been approved for use with the product and that it matches the voltage and current marked on the product’s electrical range label. The voltage and current rating of the cord must be greater than the voltage and current rating marked on the product. 10. All cautions and warnings on the equipment should be noted. 11. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage. 12. Never pour any liquid into an opening. This may cause fire or electrical shock. 13. Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel. 14. If one of the following situations arises, get the equipment checked by service personnel: i. The power cord or plug is damaged. ii. Liquid has penetrated into the equipment. iii. The equipment has been exposed to moisture. iv. The equipment does not work well, or you cannot get it to work according to the user’s manual. v. The equipment has been dropped and damaged. vi. The equipment has obvious signs of breakage. 15. Do not place heavy objects on the equipment. 16. The system follows the national requirement to dispose unit
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Technical Support and Assistance 1. For the most updated information of products, visit Barco website at www.barco.com. 2. For technical issues that require contacting our technical support team or sales representative, please have the following information ready before calling: – Product name and serial number – Detailed information of the peripheral devices – Detailed information of the installed software (operating system, version, application software, etc.) – A complete description of the problem – The exact wordings of the error messages  Warning 1. Handling the unit: carry the unit with both hands and handle it with care. 2. Maintenance: to keep the unit clean, uses only approved cleaning products or clean with a dry cloth. 3. To avoid risk of electric shock, this equipment must only be connected to a supply with protective earth 4. Do not modify this equipment without authorization of the manufacturer. Warning 1. Manipulation de l'appareil : réaliser l'unité avec les deux mains et manipuler avec soin .   2. Entretien: Pour garder l'unité propre, utilise des produits de nettoyage approuvés ou nettoyer avec un chiffon sec .   3. Pour éviter tout risque de choc électrique , cet équipement ne doit être connecté à une alimentation avec de la terre de protection   4. Ne pas modifier cet équipement sans l'autorisation du constructeur
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Conventions Used in this Manual Warning: Information about certain situations, which if not observed, can cause personal injury. This will prevent injury to you when performing a task.    Caution: Information to avoid damaging components or losing data.   Note: Provides additional information to complete a task easily
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Symbol Glossary There are some symbols marks on user manual, label, carton and product, each symbol has its purpose, please take notice the symbol identification before use.   Book mark Read the manual before start operate the system  Power key   Power  key  use  to  control  system  status  such  as  reset or  set enable panel backlight.  RFID and SMC This system work with contact and contactless reader.    Service call The system has 4pin service call. It connects to back end service system with 4 wire signal pin  USB Usb port symbol. The system support USB2.0 IO.  Network The system support 10/100/1000 Mbps Ethernet connection.  Line out   3.5mm earphone jack supports line out signal.  HDMI HDMI signal, the system support HDMI input on this port  GND Ground pin for system. (Panel  PC  with  external  power  supply:  class  II  with  functional earth equipment)  AC power symbol Information for AC power input range of PSU  DC power symbol Information for DC power input range of system
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Ordering Information The following information below provides ordering information.  JAO 15 / ST156BIPC000 (P/N: 10Q0ST15600X1)  15.6” bedside terminal, Intel Bay Trail J1900 2.0GHz, resistive touch screen, 2GB DDR3L, 32GB MLC SSD, 13.56MHz RFID and smart card reader  JAO18/ ST185DIPC000 (P/N: 10Q0ST18500X1)  18.5” bedside terminal, Intel Bay Trail J1900 2.0GHz, PCAP touch screen, 2GB DDR3L, 32GB MLC SSD, 13.56MHz RFID and smart card reader
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Product Introduction JAO15 Overview JAO 15 is designed to serve as a Point of Care (POC) and Point of Information terminal (POI) within healthcare applications. Manufactured using anti-bacterial plastics, the terminals provide a host of interactive healthcare applications providing secure access to Electronic Medical Records (EMR) and innovative triple-play solutions (web, IPTV, VoIP) for patient entertainment.        Key Features  16:9 15.6” 1366x768 Fanless LED Panel Computer  Intel® Celeron® J1900, Quad Core, Low Consumption CPU  Flat Panel by Resistive Touch Screen  With 1x GbE/ HDMI input/ 5x USB ports  Built in speaker/ microphone/ 2x line out  13.56MHz RFID/ Smart card reader  DDR3L 2GB/ 2.5” 32GB SSD    System Power Input 19V DC
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Specification Panel - LED size: 15.6”, 16:9 - Resolution: 1366x768 - Luminance: 300 cd/m2 - Contrast ratio: 500 - LED color: 16.7M - Viewing Angle: 80(U) 80(D) 80(L) 80(R) - Backlight: LED  Touch Screen - 5 wire Resistive touch - Light transmission: 78% - Interface: USB  System - CPU: On-board Intel® Celeron® J1900, 2.0GHz,2M L2 Cache - BIOS: AMI BIOS - IO chipset: ITE 8786 - System memory: 1x 204-pin DDR3L SO-DIMM socket, 2G DDR3L (Default), support up to 8GB DDR3L-1333, Non-ECC and un-buffered - Storage Device: 1x 2.5” SATA HDD - Watchdog timer: Watchdog timeout can be programmed by software. from 1 second to 255 seconds and from 1 minute to 255 minutes (Tolerance 15% under room temperature 25°C) - H/W status monitor: Monitoring system temperature, and voltage - Expansion: 1x mini-PCIe sockets  I/O - Ethernet: 1x RJ45 - USB: 5 x USB 2.0 - Audio port: 2x Line out/built in speaker and microphone - HDMI input connector   - Front touch icon - 720p camera  Audio - HDA codec: Realtek ALC886-GR - Audio interface: Line out Audio Jack Ethernet - LAN chip: Intel® I210AT Gigabit LAN - Ethernet interface: 10/100/1000 Based-Tx Ethernet compatible  Wifi & BT (optional)
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   - Certified module BOINTE PE809-AA - Support 802.11 b/g/n - Support BT 4.0  Mechanical & Environment - Color: white, pantone RAL9016 - Vibration:  IEC 68 2-64 (w/ HDD)  1Grms @ sine, 5~500Hz, 1hr/axis (HDD Operating) - Shock:  IEC 68 2-27  HDD: 20G@panel mount, half sine, 11ms - Operating temperature: 0°C to 40°C - Storage temperature: -20°C to 60°C - Operating/Storage humidity: 20%~80% relative humidity, non-condensing - The humidity preconditioning treatment is performed in a humidity cabinet containing air with a relative humidity of 93%RH @25°C 48hrs   - Storage Altitude: up to 3000M - Dimension: 417.2x 266.6x50 mm - Weight: 4.5 Kg  Power Supply - Model: DELTA MDS-090AAS19 B - Power input: 100-240V~ 1.5-0.75A 50-60Hz - Power Output: 19VDC, 4.74A  Certifications - CE   - FCC class B - EN60601-1 - UL60601-1 - IEC 60950-1 CB - ANSI/AAMI ES60601-1* - CAN/CSA-C22.2 No.60601-1*  * This panel pc incorporates the ES60601-1 /IEC60601-1 certified power supply, Model MDS-090AAS19 B is by DELTA. The power supply is used in the conditions of overvoltage category II, Pollution Degree II.  *This panel pc incorporates the power supply is Class II with functional earth AC/DC Adapter intended for supplying medical electrical apparatus with two parts of plastic enclosure fixed together by screws
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   JAO18   Overview JAO 18 is designed to serve as a Point of Care (POC) and Point of Information terminal (POI) within healthcare applications. Manufactured using anti-bacterial plastics, the terminals provide a host of interactive healthcare applications providing secure access to Electronic Medical Records (EMR) and innovative triple-play solutions (web, IPTV, VoIP) for patient entertainment.        Key Features  16:9 18.5” 1366x768 Fanless LED Panel Computer  Intel® Celeron® J1900, Quad Core, Low Consumption CPU  Flat Panel by PCAP Touch Screen  With 1x GbE/ HDMI input/ 5x USB ports  Built in speaker/ microphone/ 2x line out  13.56MHz RFID/ Smart card reader  DDR3L 2GB/ 2.5” 32GB SSD    System Power Input 19V DC 
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Specification Panel - LED size: 18.5”, 16:9 - Resolution: 1366X768 - Luminance: 300 cd/m2 - Contrast ratio: 1000 - LED color: 16.7M - Viewing Angle: 80(U) 80(D) 85(L) 85(R) - Backlight: LED  Touch Screen - PCAP touch - Light transmission: 87% - Interface: USB  System - CPU: On-board Intel® Celeron® J1900, 2.0GHz,2M L2 Cache - BIOS: AMI BIOS - IO chipset: ITE 8786 - System memory: 1x 204-pin DDR3L SO-DIMM socket, 2G DDR3L (Default), support up to 8GB DDR3L-1333, Non-ECC and un-buffered - Storage Device: 1x 2.5” SATA HDD - Watchdog timer: Watchdog timeout can be programmed by software. from 1 second to 255 seconds and from 1 minute to 255 minutes (Tolerance 15% under room temperature 25°C) - H/W status monitor: Monitoring system temperature, and voltage - Expansion: 1x mini-PCIe sockets  I/O - Ethernet: 1x RJ45 - USB: 5 x USB 2.0 - Audio port: 2x Line out/built in speaker and microphone - HDMI input connector   - Front touch icon - 720p camera - Optional barcode scanner (IEC62471 certified)  Audio - HDA codec: Realtek ALC886-GR - Audio interface: Line out Audio Jack Ethernet - LAN chip: Intel® I210AT Gigabit LAN - Ethernet interface: 10/100/1000 Based-Tx Ethernet compatible Wifi & BT (optional)
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   - Certified module BOINTE PE809-AA - Support 802.11 b/g/n - Support BT 4.0  Mechanical & Environment - Color: white, pantone RAL9016 - Vibration:  IEC 68 2-64 (w/ HDD)  1Grms @ sine, 5~500Hz, 1hr/axis (HDD Operating) - Shock:  IEC 68 2-27  HDD: 20G@panel mount, half sine, 11ms - Operating temperature: 0°C to 40°C - Storage temperature: -20°C to 60°C - Operating/Storage humidity: 20%~80% relative humidity, non-condensing - The humidity preconditioning treatment is performed in a humidity cabinet containing air with a relative humidity of 93%RH @25°C 48hrs   - Storage Altitude: up to 3000M - Dimension: 481.6x308.2x50 mm - Weight: 4.7 Kg  Power Supply - Model: DELTA MDS-090AAS19 B - Power input: 100-240V~ 1.5-0.75A 50-60Hz - Power Output: 19VDC, 4.74A   Certifications - CE   - FCC class B - EN60601-1 - UL60601-1 - IEC 60950-1 CB - ANSI/AAMI ES60601-1* - CAN/CSA-C22.2 No.60601-1*  * This panel pc incorporates the ES60601-1 /IEC60601-1 certified power supply, Model MDS-090AAS19 B is by DELTA. The power supply is used in the conditions of overvoltage category II, Pollution Degree II.  *This panel pc incorporates the power supply is Class II with functional earth AC/DC Adapter intended for supplying medical electrical apparatus with two parts of plastic enclosure fixed together by screws
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   IO introduction    Front side         Camera 720p camera with white LED  RFID and smart card reader 13.56MHz RFID and smart card reader. RFID tag also readable while parking in smart card reader slot  Power Key Touch icon input. Long press 5 seconds to turn on panel backlight; long press 10 seconds to reset or power off system.
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Back side     HDD service door Lock with Torx screws, use for SSD replacement  RAM and miniPCIe service door Lock with Torx screws, use for RAM replacement or install extension module   Rear IO 19V DC input  connect to PSU   Service call    connect to back end service system (intra network) with 4 wire signal pin USB       3x USB 2.0 ports LAN       Gigabit Ethernet  Bottom IO Line out      2x line out jack USB       2x USB 2.0 ports with 1.5A V HDMI      use as HDMI input  Barcode Scanner (optional) Optional install 1D/2D supported barcode scanner module  Microphone Built in digital microphone  Speaker Built in stereo speaker
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Mechanical Dimensions JAO15  JAO18
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Jumpers and ConnectorsThis chapter describes how to set the jumpers and connectors on the motherboard.   Before you Begin  Ensure you have a stable, clean working environment. Dust and dirt can get into components and cause a malfunction. Use containers to keep small components separated.  Adequate lighting and proper tools can prevent you from accidentally damaging the internal components. Most of the procedures that follow require only a few simple tools, including the following: - A Philips screwdriver   - A flat-tipped screwdriver - A set of jewelers screwdrivers - A grounding strap - An anti-static pad  Using your fingers can disconnect most of the connections. It is recommended that you do not use needle-nosed pliers to disconnect connections as these can damage the soft metal or plastic parts of the connectors.  Before working on internal components, make sure that the power is off. Ground yourself before touching any internal components, by touching a metal object. Static electricity can damage many of the electronic components. Humid environments tend to have less static electricity than dry environments. A grounding strap is warranted whenever danger of static electricity exists. Precautions Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the guidelines below to avoid damage to your computer or yourself:  Always disconnect the unit from the power outlet whenever you are working inside the case.  To fully disengage the power to the unit, please disconnect the power cord from the AC inlet.  If possible, wear a grounded wrist strap when you are working inside the computer case. Alternatively, discharge any static electricity by touching the bare metal chassis of the unit case, or the bare metal body of any other grounded appliance  Hold electronic circuit boards by the edges only. Do not touch the components on the board unless it is necessary to do so. Don’t flex or stress the circuit board.
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.    Leave all components inside the static-proof packaging that they shipped with until they are ready for installation. Use correct screws and do not over tighten screws. Jumper Setting A jumper is the simplest kind of electric switch. It consists of two metal pins and a cap. When setting the jumpers, ensure that the jumper caps are placed on the correct pins. When the jumper cap is placed on both pins, the jumper is short. If you remove the jumper cap, or place the jumper cap on just one pin, the jumper is open.  Refer to the illustrations below for examples of what the 2-pin and 3-pin jumpers look like when they are short (on) and open (off).    Two-Pin Jumpers: Open (Left) and Short (Right)  Three-Pin Jumpers: Pins 1 and 2 are Short
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Locations of the Jumpers and Connectors Top View  Jumpers and DIP Switch Setting  CMOS Clear Select  Connector type: 1x3 3-pin header, 2.54mm pitch Connector location: JBIOS1    Pin  Settings 1-2 ON  Normal 2-3 ON  Clear BIOS
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Connector Pin DefinitionExternal I/O Interface19V DC Power Input Connector type: 5.5mm DC jack      HDMI Input Port Connector type: HDMI Female connector  Pin  Definition  Pin  Definition 1  TMDS Data2+  11  TMDS Clock Shield 2  TMDS Data2 Shield  12  TMDS Clock– 3  TMDS Data2–  13  CEC 4  TMDS Data1+  14  N.C 5  TMDS Data1 Shield  15  SCL 6  TMDS Data1–  16  SDA 7  TMDS Data0+  17  DDC/CEC Ground 8  TMDS Data0 Shield  18  +5 V Power 9  TMDS Data0–  19  Hot Plug Detect 10  TMDS Clock+     REAR IO USB PORT Connector type: USB type A female
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.     USB Pin  Definition 1  VCC5 2  USB 0- 3  USB 0+ 4  GND  Service Call connector   Connector type: 6 pin RJ 11 connector     Service call Pin  Definition 2  Service call + 3  Service call - 4  Handset LED + 5  Handset LED -
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   LAN Ports Connector type: RJ45 port with LEDs   ACT  Status   LINK  Status Yellow blinking Data activity   Steady green  1000M link Off  No activity    Steady orange 100M link       Off  10M or no link     Pin  Definition  Pin  Definition 1  LAN M0+  5  LAN M2- 2  LAN M0-  6  LAN M1- 3  LAN M1+  7  LAN M3+ 4  LAN M2+  8  LAN M3- Line-out Jack Connector type: 3.5mm Earphone Jack    Pin  Definition 1  LOUT_R 2  JD 3  NC 4  LOUT_L 5  GND 6  GND
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Internal Connectors SATA Connector location: SATA1  Pin  Signal  Pin  Signal S1  GND  S2  SATA_TX0P S3  SATA_TX0N  S4  GND S5  SATA_RX0N  S6  SATA_RX0P S7  GND  P1  VCC3 P2  VCC3  P3  VCC3 P4  GND  P5  GND P6  GND  P7  VCC5 P8  VCC5  P9  VCC5 P10  GND  P11  NC P12  GND  P13  VCC12 P14  VCC12  P15  VCC12
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Mini-PCIe Slot Connector location: CN2  Pin  Signal  Pin  Signal  Pin  Signal  Pin  Signal 1  WAKE0#  2  3.3V_MINI  27  GND  28  +1.5V_MINI 3  NC  4  GND  29  GND  30  SMB_CLK 5  NC  6  1.5V_MINI  31  PCIE_TX3-  32  SMB_DAT 7  PCIE_CLKREQ  8  NC  33  PCIE_TX3+  34  GND 9  GND  10  NC  35  GND  36  USB- 11  GPP_CLK1-  12  NC  37  GND  38  USB+ 13  GPP_CLK1+  14  NC  39  +3.3V_MINI  40  GND 15  GND  16  NC  41  +3.3V_MINI  42  NC 17  NC  18  GND  43  GND  44  NC 19  NC  20  MINICARD1_DIS#  45  NC  46  NC 21  GND  22  PCIE_RST#  47  NC  48  +1.5V_MINI 23  PCIE_RX2-  24  3.3V_MINI  49  NC  50  GND 25  PCIE_RX2+  26  GND  51  NC  52  +3.3V_MINI
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   System Setup Prior to removing the chassis cover, make sure the unit’s power is off and disconnected from the power sources to prevent electric shock or system damage. To fully disengage the power to the unit, please disconnect the power cord from the AC inlet  Avant de retirer le capot du châssis , assurez-vous que la puissance de l'appareil est éteint et déconnecté de la source d'alimentation pour éviter un choc électrique ou d'un système de dégâts. Pour dégager pleinement la puissance à l'unité , s'il vous plaît débrancher le cordon d'alimentation de la prise secteur  System setup and use in different environment. In normal use condition, System button IO is toward to ground for better system performance. In which means system usually install where panel face to user. Replace SATA Disk    1. Loose the screw of HDD service door.   2. Remove current SATA and replace with new one.
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   Replace RAM  1. Loose the screw of RAM service door.   2. Remove DDR3L RAM module and replace with new one. 3.
 Interactive Patient Care – Barco Healthcare Division   CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco.    No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.   System Mounting  There are different mount types to fix system in bracket or arm. In system accessory pack, there are 4 M4 screws. Length of screw teeth should be 5mm. Screw should be fasten to back cover by 8KG torque.