Barco N V JAO1801 Panel PC User Manual 106B3A63
Barco N.V. Panel PC 106B3A63
Contents
- 1. User Manual
- 2. Users Manual
Users Manual
BARCO LTD. 33F., No. 16 &No.16-1, Xizhan Rd., Banqiao Dist., New Taipei City 220, Taiwan (R.O.C.) Telephone: +886-2-7715-0299 Fax: +886-2-7715-0298 BARCO Panel PC JAO15/ JAO18 User Manual Version: 1.2 Interactive Patient Care – Barco Healthcare Division Content Locations of the Jumpers and Connectors ................................................... 22 Top View ............................................................................................... 22 Jumpers and DIP Switch Setting ................................................................... 22 Safety Precautions ......................................................................................... 6 Technical Support and Assistance .................................................................. 7 Conventions Used in this Manual .................................................................. 7 Ordering Information ................................................................................... 10 CMOS Clear Select ................................................................................ 22 Connector Pin Definition .............................................................................. 23 External I/O Interface ........................................................................... 23 19V DC Power Input ..................................................................... 23 REAR IO USB PORT ....................................................................... 23 Service Call connector .................................................................. 24 Line-out Jack................................................................................. 25 Internal Connectors .............................................................................. 26 SATA .............................................................................................. 26 Mini-PCIe Slot ............................................................................... 27 Block Diagram .......................................................... 錯誤! 錯誤 尚未定義書籤。 尚未定義書籤。 Chapter 1: Product Introduction .................................................................. 11 JAO15 ................................................................................................... 11 JAO18 ................................................................................................... 14 IO introduction ............................................................................................. 17 Chapter 3: System Setup ...................................................................... 28 Replace SATA Disk................................................................................. 28 Replace RAM ........................................................................................ 28 Install Handset.................................................. 錯誤! 錯誤 尚未定義書籤。 尚未定義書籤。 Preface ........................................................................................................... 3 Copyright................................................................................................ 3 Disclaimer .............................................................................................. 3 Acknowledgements ............................................................................... 3 Regulatory Compliance Statements....................................................... 3 Declaration of Conformity ..................................................................... 3 RoHS Compliance ........................................................................................... 4 Mechanical Dimensions ............................................................................... 19 JAO15 ................................................................................................... 19 JAO18 ................................................................................................... 19 Chapter2: Jumpers and Connectors............................................................. 20 Before you Begin .................................................................................. 20 Jumper Setting ..................................................................................... 21 CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Preface Copyright This publication, including all photographs, illustrations and software, is protected under international copyright laws, with all rights reserved. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written consent from BARCO. Disclaimer The information in this document is subject to change without prior notice and does not represent commitment from BARCO International Co., Ltd. However, users may update their knowledge of any product in use by constantly checking its manual posted on our website: http://www.barco.com. BARCO shall not be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of any product, nor for any infringements upon the rights of third parties, which may result from such use. Any implied warranties of merchantability or fitness for any particular purpose is also disclaimed. Acknowledgements ST156B/ST185D is a trademark of BARCO. All other product names mentioned herein are registered trademarks of their respective owners. Regulatory Compliance Statements This section provides the FCC compliance statement for Class A devices and describes how to keep the system CE compliant. Declaration of Conformity FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the European Union (CE) directives if it has a CE marking. For computer systems to remain CE compliant, only CE-compliant parts may be used. Maintaining CE compliance also requires proper cable and cabling techniques. equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: IEC/ISO Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that All components and wirings comply with IEC or ISO standard, except for Plastic Enclosure is UL approved only RoHS Compliance to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. . FCC Caution: Any changes or modifications not expressly approved by the party BARCO RoHS Environmental Policy and Status Update This publication, including all photographs, illustrations and software, is responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. protected under international copyright laws, with all rights reserved. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written consent from BARCO. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and RoHS restricts the use of Lead (Pb) < 0.1% or 1,000ppm, Mercury (Hg) < 0.1% or 1,000ppm, Cadmium (Cd) < 0.01% or 100ppm, Hexavalent Chromium (Cr6+) < 0.1% or 1,000ppm, Polybrominated biphenyls (PBB) < 0.1% or 1,000ppm, and Polybrominated diphenyl Ethers (PBDE) < 0.1% or operated with minimum distance 20cm between the radiator & your body. CE The product(s) described in this manual complies with all applicable 1,000ppm. In order to meet the RoHS compliant directives, BARCO has established an engineering and manufacturing task force to implement the introduction of green products. The task force will ensure that we follow the standard CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry quality levels for which BARCO are renowned. The model selection criteria will be based on market demand. Vendors and suppliers will ensure that all designed components will be RoHS compliant. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Safety Precautions 1. Read these safety instructions carefully. 2. Keep this User Manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6. Put this equipment on a stable surface during installation. Dropping it or letting it fall may cause damage. 7. The openings on the enclosure are for air convection to protect the equipment from overheating. DO NOT COVER THE OPENINGS. 8. Make sure the voltage of the power source is correct before connecting the equipment to the power outlet. 9. 12. Never pour any liquid into an opening. This may cause fire or electrical shock. 13. Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel. 14. If one of the following situations arises, get the equipment checked by service personnel: i. The power cord or plug is damaged. ii. Liquid has penetrated into the equipment. iii. The equipment has been exposed to moisture. iv. The equipment does not work well, or you cannot get it to work according to the user’s manual. v. The equipment has been dropped and damaged. vi. The equipment has obvious signs of breakage. 15. Do not place heavy objects on the equipment. 16. The system follows the national requirement to dispose unit Place the power cord in a way so that people will not step on it. Do not place anything on top of the power cord. Use a power cord that has been approved for use with the product and that it matches the voltage and current marked on the product’s electrical range label. The voltage and current rating of the cord must be greater than the voltage and current rating marked on the product. 10. All cautions and warnings on the equipment should be noted. 11. If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Technical Support and Assistance 1. For the most updated information of products, visit Barco website at www.barco.com. 2. For technical issues that require contacting our technical support team or sales representative, please have the following information ready before calling: – Product name and serial number – Detailed information of the peripheral devices – Detailed information of the installed software (operating system, version, application software, etc.) – A complete description of the problem Warning 1. Manipulation de l'appareil : réaliser l'unité avec les deux mains et manipuler avec soin . 2. Entretien: Pour garder l'unité propre, utilise des produits de nettoyage approuvés ou nettoyer avec un chiffon sec . 3. Pour éviter tout risque de choc électrique , cet équipement ne doit être connecté à une alimentation avec de la terre de protection 4. Ne pas modifier cet équipement sans l'autorisation du constructeur – The exact wordings of the error messages Warning 1. Handling the unit: carry the unit with both hands and handle it with care. 2. Maintenance: to keep the unit clean, uses only approved cleaning products or clean with a dry cloth. 3. To avoid risk of electric shock, this equipment must only be connected to a supply with protective earth 4. Do not modify this equipment without authorization of the manufacturer. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Conventions Used in this Manual Warning: Information about certain situations, which if not observed, can cause personal injury. This will prevent injury to you when performing a task. Caution: Information to avoid damaging components or losing data. Note: Provides additional information to complete a task easily CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Symbol Glossary There are some symbols marks on user manual, label, carton and product, each symbol has its purpose, please take notice the symbol identification before use. Network The system support 10/100/1000 Mbps Ethernet connection. Line out 3.5mm earphone jack supports line out signal. Book mark Read the manual before start operate the system HDMI HDMI signal, the system support HDMI input on this port Power key Power key use to control system status such as reset or set enable panel backlight. GND Ground pin for system. (Panel PC with external power supply: class II with functional earth equipment) RFID and SMC This system work with contact and contactless reader. Service call The system has 4pin service call. It connects to back end service system with 4 wire signal pin AC power symbol Information for AC power input range of PSU DC power symbol Information for DC power input range of system USB Usb port symbol. The system support USB2.0 IO. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Ordering Information The following information below provides ordering information. JAO 15 / ST156BIPC000 (P/N: 10Q0ST15600X1) 15.6” bedside terminal, Intel Bay Trail J1900 2.0GHz, resistive touch screen, 2GB DDR3L, 32GB MLC SSD, 13.56MHz RFID and smart card reader JAO18/ ST185DIPC000 (P/N: 10Q0ST18500X1) 18.5” bedside terminal, Intel Bay Trail J1900 2.0GHz, PCAP touch screen, 2GB DDR3L, 32GB MLC SSD, 13.56MHz RFID and smart card reader CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Flat Panel by Resistive Touch Screen Product Introduction With 1x GbE/ HDMI input/ 5x USB ports Built in speaker/ microphone/ 2x line out JAO15 Overview JAO 15 is designed to serve as a Point of Care (POC) and Point of Information terminal (POI) within healthcare applications. Manufactured using anti-bacterial plastics, the terminals provide a host of interactive healthcare applications providing secure access to Electronic Medical Records (EMR) and innovative triple-play solutions (web, IPTV, VoIP) for patient entertainment. 13.56MHz RFID/ Smart card reader DDR3L 2GB/ 2.5” 32GB SSD System Power Input 19V DC Key Features 16:9 15.6” 1366x768 Fanless LED Panel Computer Intel® Celeron® J1900, Quad Core, Low Consumption CPU CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Specification Panel - LED size: 15.6”, 16:9 - Resolution: 1366x768 - Luminance: 300 cd/m2 - Contrast ratio: 500 - LED color: 16.7M - Viewing Angle: 80(U) 80(D) 80(L) 80(R) - Backlight: LED Touch Screen - 5 wire Resistive touch - Light transmission: 78% - Interface: USB System - CPU: On-board Intel® Celeron® J1900, 2.0GHz,2M L2 Cache - BIOS: AMI BIOS - IO chipset: ITE 8786 - System memory: 1x 204-pin DDR3L SO-DIMM socket, 2G DDR3L (Default), support up to 8GB DDR3L-1333, Non-ECC and un-buffered - Storage Device: 1x 2.5” SATA HDD - Watchdog timer: Watchdog timeout can be programmed by software. from 1 second to 255 seconds and from 1 minute to 255 minutes (Tolerance 15% under room temperature 25°C) - H/W status monitor: Monitoring system temperature, and voltage - Expansion: 1x mini-PCIe sockets I/O - Ethernet: 1x RJ45 - USB: 5 x USB 2.0 - Audio port: 2x Line out/built in speaker and microphone - HDMI input connector - Front touch icon - 720p camera Audio - HDA codec: Realtek ALC886-GR - Audio interface: Line out Audio Jack Ethernet - LAN chip: Intel® I210AT Gigabit LAN - Ethernet interface: 10/100/1000 Based-Tx Ethernet compatible Wifi & BT (optional) CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division - Certified module BOINTE PE809-AA - Support 802.11 b/g/n - Support BT 4.0 Mechanical & Environment - Color: white, pantone RAL9016 - Vibration: IEC 68 2-64 (w/ HDD) 1Grms @ sine, 5~500Hz, 1hr/axis (HDD Operating) - Shock: IEC 68 2-27 HDD: 20G@panel mount, half sine, 11ms - Operating temperature: 0°C to 40°C - Storage temperature: -20°C to 60°C - Operating/Storage humidity: 20%~80% relative humidity, non-condensing - The humidity preconditioning treatment is performed in a humidity cabinet containing air with a relative humidity of 93%RH @25°C 48hrs - Storage Altitude: up to 3000M - Dimension: 417.2x 266.6x50 mm - Weight: 4.5 Kg - Power input: 100-240V~ 1.5-0.75A 50-60Hz - Power Output: 19VDC, 4.74A Certifications - CE - FCC class B - EN60601-1 - UL60601-1 - IEC 60950-1 CB - ANSI/AAMI ES60601-1* - CAN/CSA-C22.2 No.60601-1* * This panel pc incorporates the ES60601-1 /IEC60601-1 certified power supply, Model MDS-090AAS19 B is by DELTA. The power supply is used in the conditions of overvoltage category II, Pollution Degree II. *This panel pc incorporates the power supply is Class II with functional earth AC/DC Adapter intended for supplying medical electrical apparatus with two parts of plastic enclosure fixed together by screws Power Supply - Model: DELTA MDS-090AAS19 B CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division JAO18 Overview JAO 18 is designed to serve as a Point of Care (POC) and Point of Information terminal (POI) within healthcare applications. Manufactured using anti-bacterial plastics, the terminals provide a host of interactive healthcare applications providing secure access to Electronic Medical Records (EMR) and innovative triple-play solutions (web, IPTV, VoIP) for patient entertainment. Key Features 16:9 18.5” 1366x768 Fanless LED Panel Computer Intel® Celeron® J1900, Quad Core, Low Consumption CPU Flat Panel by PCAP Touch Screen With 1x GbE/ HDMI input/ 5x USB ports Built in speaker/ microphone/ 2x line out 13.56MHz RFID/ Smart card reader DDR3L 2GB/ 2.5” 32GB SSD System Power Input 19V DC CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Specification Panel - LED size: 18.5”, 16:9 - Resolution: 1366X768 - Luminance: 300 cd/m2 - Contrast ratio: 1000 - LED color: 16.7M - Viewing Angle: 80(U) 80(D) 85(L) 85(R) - Backlight: LED Touch Screen - PCAP touch - Light transmission: 87% - Interface: USB System - CPU: On-board Intel® Celeron® J1900, 2.0GHz,2M L2 Cache - BIOS: AMI BIOS - IO chipset: ITE 8786 - System memory: 1x 204-pin DDR3L SO-DIMM socket, 2G DDR3L (Default), support up to 8GB DDR3L-1333, Non-ECC and un-buffered - Storage Device: 1x 2.5” SATA HDD - Watchdog timer: Watchdog timeout can be programmed by software. from 1 second to 255 seconds and from 1 minute to 255 minutes (Tolerance 15% under room temperature 25°C) - H/W status monitor: Monitoring system temperature, and voltage - Expansion: 1x mini-PCIe sockets I/O - Ethernet: 1x RJ45 - USB: 5 x USB 2.0 - Audio port: 2x Line out/built in speaker and microphone - HDMI input connector - Front touch icon - 720p camera - Optional barcode scanner (IEC62471 certified) Audio - HDA codec: Realtek ALC886-GR - Audio interface: Line out Audio Jack Ethernet - LAN chip: Intel® I210AT Gigabit LAN - Ethernet interface: 10/100/1000 Based-Tx Ethernet compatible Wifi & BT (optional) CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division - Certified module BOINTE PE809-AA - Support 802.11 b/g/n - Support BT 4.0 - Power input: 100-240V~ 1.5-0.75A 50-60Hz - Power Output: 19VDC, 4.74A Mechanical & Environment - Color: white, pantone RAL9016 - Vibration: IEC 68 2-64 (w/ HDD) 1Grms @ sine, 5~500Hz, 1hr/axis (HDD Operating) - Shock: IEC 68 2-27 HDD: 20G@panel mount, half sine, 11ms - Operating temperature: 0°C to 40°C - Storage temperature: -20°C to 60°C - Operating/Storage humidity: 20%~80% relative humidity, non-condensing - The humidity preconditioning treatment is performed in a humidity cabinet containing air with a relative humidity of 93%RH @25°C 48hrs - Storage Altitude: up to 3000M - Dimension: 481.6x308.2x50 mm - Weight: 4.7 Kg Certifications - CE - FCC class B - EN60601-1 - UL60601-1 - IEC 60950-1 CB - ANSI/AAMI ES60601-1* - CAN/CSA-C22.2 No.60601-1* * This panel pc incorporates the ES60601-1 /IEC60601-1 certified power supply, Model MDS-090AAS19 B is by DELTA. The power supply is used in the conditions of overvoltage category II, Pollution Degree II. *This panel pc incorporates the power supply is Class II with functional earth AC/DC Adapter intended for supplying medical electrical apparatus with two parts of plastic enclosure fixed together by screws Power Supply - Model: DELTA MDS-090AAS19 B CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division IO introduction Front side Camera 720p camera with white LED RFID and smart card reader 13.56MHz RFID and smart card reader. RFID tag also readable while parking in smart card reader slot Power Key Touch icon input. Long press 5 seconds to turn on panel backlight; long press 10 seconds to reset or power off system. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Back side Microphone Built in digital microphone HDD service door Lock with Torx screws, use for SSD replacement Speaker Built in stereo speaker RAM and miniPCIe service door Lock with Torx screws, use for RAM replacement or install extension module Rear IO 19V DC input Service call USB LAN connect to PSU connect to back end service system (intra network) with 4 wire signal pin 3x USB 2.0 ports Gigabit Ethernet Bottom IO Line out USB HDMI 2x line out jack 2x USB 2.0 ports with 1.5A V use as HDMI input Barcode Scanner (optional) Optional install 1D/2D supported barcode scanner module CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Mechanical Dimensions JAO15 JAO18 CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Jumpers and Connectors This chapter describes how to set the jumpers and connectors on the motherboard. metal object. Static electricity can damage many of the electronic components. Humid environments tend to have less static electricity than dry environments. A grounding strap is warranted whenever danger of static Before you Begin Ensure you have a stable, clean working environment. Dust and dirt can get into components and cause a malfunction. Use containers to keep small components separated. Adequate lighting and proper tools can prevent you from accidentally damaging the internal components. Most of the procedures that follow electricity exists. Precautions Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the guidelines below to avoid damage to your computer or yourself: require only a few simple tools, including the following: Always disconnect the unit from the power outlet whenever you are A Philips screwdriver working inside the case. A flat-tipped screwdriver To fully disengage the power to the unit, please disconnect the power cord A set of jewelers screwdrivers from the AC inlet. A grounding strap If possible, wear a grounded wrist strap when you are working inside the An anti-static pad computer case. Alternatively, discharge any static electricity by touching the Using your fingers can disconnect most of the connections. It is bare metal chassis of the unit case, or the bare metal body of any other recommended that you do not use needle-nosed pliers to disconnect grounded appliance connections as these can damage the soft metal or plastic parts of the Hold electronic circuit boards by the edges only. Do not touch the connectors. components on the board unless it is necessary to do so. Don’t flex or stress Before working on internal components, make sure that the power is off. the circuit board. Ground yourself before touching any internal components, by touching a CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Leave all components inside the static-proof packaging that they shipped with until they are ready for installation. Use correct screws and do not over tighten screws. Jumper Setting A jumper is the simplest kind of electric switch. It consists of two metal pins and a cap. When setting the jumpers, ensure that the jumper caps are placed on the correct pins. When the jumper cap is placed on both pins, the jumper is short. If you remove the jumper cap, or place the jumper cap on just one pin, the jumper is open. Refer to the illustrations below for examples of what the 2-pin and 3-pin jumpers look like when they are short (on) and open (off). Two-Pin Jumpers: Open (Left) and Short (Right) Three-Pin Jumpers: Pins 1 and 2 are Short CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Locations of the Jumpers and Connectors Top View Jumpers and DIP Switch Setting CMOS Clear Select Connector type: 1x3 3-pin header, 2.54mm pitch Connector location: JBIOS1 Pin Settings 1-2 ON Normal 2-3 ON Clear BIOS CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Connector Pin Definition External I/O Interface 19V DC Power Input HDMI Input Port Connector type: 5.5mm DC jack Connector type: HDMI Female connector Pin Definition Pin Definition TMDS Data2+ 11 TMDS Clock Shield TMDS Data2 Shield 12 TMDS Clock– TMDS Data2– 13 CEC TMDS Data1+ 14 N.C TMDS Data1 Shield 15 SCL TMDS Data1– 16 SDA TMDS Data0+ 17 DDC/CEC Ground TMDS Data0 Shield 18 +5 V Power TMDS Data0– 19 Hot Plug Detect 10 TMDS Clock+ REAR IO USB PORT Connector type: USB type A female CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Service Call connector USB Connector type: 6 pin RJ 11 connector Pin Definition VCC5 USB 0- USB 0+ Pin Definition GND Service call + Service call - Handset LED + Handset LED - Service call CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division LAN Ports Connector type: RJ45 port with LEDs ACT Status LINK Status Yellow blinking Data activity Steady green 1000M link Off No activity Steady orange 100M link Off 10M or no link Pin Definition Pin Definition LAN M0+ LAN M2- LAN M0- LAN M1- LAN M1+ LAN M3+ LAN M2+ LAN M3- Pin Definition LOUT_R JD NC LOUT_L GND GND Line-out Jack Connector type: 3.5mm Earphone Jack CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Internal Connectors SATA Connector location: SATA1 Pin Signal Pin Signal S1 GND S2 SATA_TX0P S3 SATA_TX0N S4 GND S5 SATA_RX0N S6 SATA_RX0P S7 GND P1 VCC3 P2 VCC3 P3 VCC3 P4 GND P5 GND P6 GND P7 VCC5 P8 VCC5 P9 VCC5 P10 GND P11 NC P12 GND P13 VCC12 P14 VCC12 P15 VCC12 CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Mini-PCIe Slot Connector location: CN2 Pin Signal Pin Signal Pin Signal Pin Signal WAKE0# 3.3V_MINI 27 GND 28 +1.5V_MINI NC GND 29 GND 30 SMB_CLK NC 1.5V_MINI 31 PCIE_TX3- 32 SMB_DAT PCIE_CLKREQ NC 33 PCIE_TX3+ 34 GND GND 10 NC 35 GND 36 USB- 11 GPP_CLK1- 12 NC 37 GND 38 USB+ 13 GPP_CLK1+ 14 NC 39 +3.3V_MINI 40 GND 15 GND 16 NC 41 +3.3V_MINI 42 NC 17 NC 18 GND 43 GND 44 NC 19 NC 20 MINICARD1_DIS# 45 NC 46 NC 21 GND 22 PCIE_RST# 47 NC 48 +1.5V_MINI 23 PCIE_RX2- 24 3.3V_MINI 49 NC 50 GND 25 PCIE_RX2+ 26 GND 51 NC 52 +3.3V_MINI CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division System Setup Prior to removing the chassis cover, make sure the unit’s power is off and disconnected from the power sources to prevent electric shock or system damage. Replace SATA Disk To fully disengage the power to the unit, please disconnect the power cord from the AC inlet 1. Loose the screw of HDD service door. 2. Remove current SATA and replace with new one. Avant de retirer le capot du châssis , assurez-vous que la puissance de l'appareil est éteint et déconnecté de la source d'alimentation pour éviter un choc électrique ou d'un système de dégâts. Pour dégager pleinement la puissance à l'unité , s'il vous plaît débrancher le cordon d'alimentation de la prise secteur System setup and use in different environment. In normal use condition, System button IO is toward to ground for better system performance. In which means system usually install where panel face to user. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division Replace RAM 1. Loose the screw of RAM service door. 2. Remove DDR3L RAM module and replace with new one. 3. CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco. Interactive Patient Care – Barco Healthcare Division System Mounting accessory pack, there are 4 M4 screws. Length of screw teeth should be 5mm. Screw should be fasten to back cover by 8KG torque. There are different mount types to fix system in bracket or arm. In system CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any purpose other than authorized by Barco.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Extract XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 2015:12:22 13:44:41+08:00 Creator Tool : PDFCreator Version 1.2.3 Modify Date : 2015:12:22 13:47:17+08:00 Metadata Date : 2015:12:22 13:47:17+08:00 Format : application/pdf Description : Creator : annkuo Title : 106B3A63 Keywords : Producer : GPL Ghostscript 9.04 Document ID : uuid:9d034e3d-55d0-4600-ab2b-d51f94eb2de8 Instance ID : uuid:68039773-26c9-41f1-b45e-6af0dca3e8a2 Page Count : 30 Subject : Author : annkuoEXIF Metadata provided by EXIF.tools