Barco N V JAO1801 Panel PC User Manual 106B3A63

Barco N.V. Panel PC 106B3A63

Contents

User Manual

Download: Barco N V JAO1801 Panel PC User Manual 106B3A63
Mirror Download [FCC.gov]Barco N V JAO1801 Panel PC User Manual 106B3A63
Document ID2883343
Application IDnZouOvCSKEvpgGbgA2I5dA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize18.72kB (234021 bits)
Date Submitted2016-01-25 00:00:00
Date Available2016-07-24 00:00:00
Creation Date2015-12-22 13:44:41
Producing SoftwareGPL Ghostscript 9.04
Document Lastmod2015-12-22 13:47:17
Document Title106B3A63
Document CreatorPDFCreator Version 1.2.3
Document Author: annkuo

BARCO LTD.
33F., No. 16 &No.16-1, Xizhan Rd., Banqiao Dist., New Taipei City 220,
Taiwan (R.O.C.)
Telephone: +886-2-7715-0299 Fax: +886-2-7715-0298
BARCO
Panel PC
JAO15/ JAO18
User Manual
Version: 1.2
Interactive Patient Care – Barco Healthcare Division
Content
Locations of the Jumpers and Connectors ................................................... 22
Top View ............................................................................................... 22
Jumpers and DIP Switch Setting ................................................................... 22
Safety Precautions ......................................................................................... 6
Technical Support and Assistance .................................................................. 7
Conventions Used in this Manual .................................................................. 7
Ordering Information ................................................................................... 10
CMOS Clear Select ................................................................................ 22
Connector Pin Definition .............................................................................. 23
External I/O Interface ........................................................................... 23
19V DC Power Input ..................................................................... 23
REAR IO USB PORT ....................................................................... 23
Service Call connector .................................................................. 24
Line-out Jack................................................................................. 25
Internal Connectors .............................................................................. 26
SATA .............................................................................................. 26
Mini-PCIe Slot ............................................................................... 27
Block Diagram .......................................................... 錯誤!
錯誤 尚未定義書籤。
尚未定義書籤。
Chapter 1: Product Introduction .................................................................. 11
JAO15 ................................................................................................... 11
JAO18 ................................................................................................... 14
IO introduction ............................................................................................. 17
Chapter 3: System Setup ...................................................................... 28
Replace SATA Disk................................................................................. 28
Replace RAM ........................................................................................ 28
Install Handset.................................................. 錯誤!
錯誤 尚未定義書籤。
尚未定義書籤。
Preface ........................................................................................................... 3
Copyright................................................................................................ 3
Disclaimer .............................................................................................. 3
Acknowledgements ............................................................................... 3
Regulatory Compliance Statements....................................................... 3
Declaration of Conformity ..................................................................... 3
RoHS Compliance ........................................................................................... 4
Mechanical Dimensions ............................................................................... 19
JAO15 ................................................................................................... 19
JAO18 ................................................................................................... 19
Chapter2: Jumpers and Connectors............................................................. 20
Before you Begin .................................................................................. 20
Jumper Setting ..................................................................................... 21
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Preface
Copyright
This publication, including all photographs, illustrations and software, is
protected under international copyright laws, with all rights reserved. No
part of this manual may be reproduced, copied, translated or transmitted
in any form or by any means without the prior written consent from
BARCO.
Disclaimer
The information in this document is subject to change without prior notice
and does not represent commitment from BARCO International Co., Ltd.
However, users may update their knowledge of any product in use by
constantly checking its manual posted on our website:
http://www.barco.com. BARCO shall not be liable for direct, indirect,
special, incidental, or consequential damages arising out of the use of any
product, nor for any infringements upon the rights of third parties, which
may result from such use. Any implied warranties of merchantability or
fitness for any particular purpose is also disclaimed.
Acknowledgements
ST156B/ST185D is a trademark of BARCO. All other product names
mentioned herein are registered trademarks of their respective owners.
Regulatory Compliance Statements
This section provides the FCC compliance statement for Class A devices and
describes how to keep the system CE compliant.
Declaration of Conformity
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the
European Union (CE) directives if it has a CE marking. For computer systems
to remain CE compliant, only CE-compliant parts may be used. Maintaining
CE compliance also requires proper cable and cabling techniques.
equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:
IEC/ISO
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that
All components and wirings comply with IEC or ISO standard, except for
Plastic Enclosure is UL approved only
RoHS Compliance
to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
. FCC Caution:
Any changes or modifications not expressly approved by the party
BARCO RoHS Environmental Policy and Status
Update
This publication, including all photographs, illustrations and software, is
responsible for compliance could void the user's authority to operate
this equipment.
This transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.
protected under international copyright laws, with all rights reserved. No
part of this manual may be reproduced, copied, translated or transmitted
in any form or by any means without the prior written consent from
BARCO.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and
RoHS restricts the use of Lead (Pb) < 0.1% or 1,000ppm, Mercury (Hg) <
0.1% or 1,000ppm, Cadmium (Cd) < 0.01% or 100ppm, Hexavalent
Chromium (Cr6+) < 0.1% or 1,000ppm, Polybrominated biphenyls (PBB) <
0.1% or 1,000ppm, and Polybrominated diphenyl Ethers (PBDE) < 0.1% or
operated with minimum distance 20cm between the radiator & your body.
CE
The product(s) described in this manual complies with all applicable
1,000ppm.
In order to meet the RoHS compliant directives, BARCO has established an
engineering and manufacturing task force to implement the introduction of
green products. The task force will ensure that we follow the standard
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
development procedure and that all the new RoHS components and new
manufacturing processes maintain the highest industry quality levels for
which BARCO are renowned.
The model selection criteria will be based on market demand. Vendors and
suppliers will ensure that all designed components will be RoHS compliant.
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Safety Precautions
1.
Read these safety instructions carefully.
2.
Keep this User Manual for later reference.
3.
Disconnect this equipment from any AC outlet before cleaning. Use a damp
cloth. Do not use liquid or spray detergents for cleaning.
4.
For plug-in equipment, the power outlet socket must be located near the
equipment and must be easily accessible.
5.
Keep this equipment away from humidity.
6.
Put this equipment on a stable surface during installation. Dropping it or
letting it fall may cause damage.
7.
The openings on the enclosure are for air convection to protect the
equipment from overheating. DO NOT COVER THE OPENINGS.
8.
Make sure the voltage of the power source is correct before connecting the
equipment to the power outlet.
9.
12. Never pour any liquid into an opening. This may cause fire or electrical
shock.
13. Never open the equipment. For safety reasons, the equipment should be
opened only by qualified service personnel.
14. If one of the following situations arises, get the equipment checked by
service personnel:
i.
The power cord or plug is damaged.
ii.
Liquid has penetrated into the equipment.
iii.
The equipment has been exposed to moisture.
iv.
The equipment does not work well, or you cannot get it to work
according to the user’s manual.
v.
The equipment has been dropped and damaged.
vi.
The equipment has obvious signs of breakage.
15. Do not place heavy objects on the equipment.
16. The system follows the national requirement to dispose unit
Place the power cord in a way so that people will not step on it. Do not place
anything on top of the power cord. Use a power cord that has been
approved for use with the product and that it matches the voltage and
current marked on the product’s electrical range label. The voltage and
current rating of the cord must be greater than the voltage and current
rating marked on the product.
10. All cautions and warnings on the equipment should be noted.
11. If the equipment is not used for a long time, disconnect it from the power
source to avoid damage by transient overvoltage.
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Technical Support and Assistance
1. For the most updated information of products, visit Barco website at
www.barco.com.
2. For technical issues that require contacting our technical support team
or sales representative, please have the following information ready
before calling:
– Product name and serial number
– Detailed information of the peripheral devices
– Detailed information of the installed software (operating system,
version, application software, etc.)
– A complete description of the problem
Warning
1. Manipulation de l'appareil : réaliser l'unité avec les deux mains et
manipuler avec soin .
2. Entretien: Pour garder l'unité propre, utilise des produits de nettoyage
approuvés ou nettoyer avec un chiffon sec .
3. Pour éviter tout risque de choc électrique , cet équipement ne doit être
connecté à une alimentation avec de la terre de protection
4. Ne pas modifier cet équipement sans l'autorisation du constructeur
– The exact wordings of the error messages
Warning
1. Handling the unit: carry the unit with both hands and handle it with care.
2. Maintenance: to keep the unit clean, uses only approved cleaning
products or clean with a dry cloth.
3. To avoid risk of electric shock, this equipment must only be connected to
a supply with protective earth
4. Do not modify this equipment without authorization of the
manufacturer.
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Conventions Used in this Manual
Warning:
Information about certain situations, which if not observed, can cause
personal injury. This will prevent injury to you when performing a task.
Caution:
Information to avoid damaging components or losing data.
Note:
Provides additional information to complete a task easily
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Symbol Glossary
There are some symbols marks on user manual, label, carton and product,
each symbol has its purpose, please take notice the symbol identification
before use.
Network
The system support 10/100/1000 Mbps Ethernet connection.
Line out
3.5mm earphone jack supports line out signal.
Book mark
Read the manual before start operate the system
HDMI
HDMI signal, the system support HDMI input on this port
Power key
Power key use to control system status such as reset or set
enable panel backlight.
GND
Ground pin for system.
(Panel PC with external power supply: class II with functional
earth equipment)
RFID and SMC
This system work with contact and contactless reader.
Service call
The system has 4pin service call. It connects to back end
service system with 4 wire signal pin
AC power symbol
Information for AC power input range of PSU
DC power symbol
Information for DC power input range of system
USB
Usb port symbol. The system support USB2.0 IO.
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Ordering Information
The following information below provides ordering information.
JAO 15 / ST156BIPC000 (P/N: 10Q0ST15600X1)
15.6” bedside terminal, Intel Bay Trail J1900 2.0GHz, resistive touch screen, 2GB DDR3L, 32GB MLC SSD, 13.56MHz RFID and smart card reader
JAO18/ ST185DIPC000 (P/N: 10Q0ST18500X1)
18.5” bedside terminal, Intel Bay Trail J1900 2.0GHz, PCAP touch screen, 2GB DDR3L, 32GB MLC SSD, 13.56MHz RFID and smart card reader
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Flat Panel by Resistive Touch Screen
Product Introduction
With 1x GbE/ HDMI input/ 5x USB ports
Built in speaker/ microphone/ 2x line out
JAO15
Overview
JAO 15 is designed to serve as a Point of Care (POC) and Point of
Information terminal (POI) within healthcare applications. Manufactured
using anti-bacterial plastics, the terminals provide a host of interactive
healthcare applications providing secure access to Electronic Medical
Records (EMR) and innovative triple-play solutions (web, IPTV, VoIP) for
patient entertainment.
13.56MHz RFID/ Smart card reader
DDR3L 2GB/ 2.5” 32GB SSD
System Power Input 19V DC
Key Features
16:9 15.6” 1366x768 Fanless LED Panel Computer
Intel® Celeron® J1900, Quad Core, Low Consumption CPU
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Specification
Panel
- LED size: 15.6”, 16:9
- Resolution: 1366x768
- Luminance: 300 cd/m2
- Contrast ratio: 500
- LED color: 16.7M
- Viewing Angle: 80(U) 80(D) 80(L) 80(R)
- Backlight: LED
Touch Screen
- 5 wire Resistive touch
- Light transmission: 78%
- Interface: USB
System
- CPU: On-board Intel® Celeron® J1900, 2.0GHz,2M L2 Cache
- BIOS: AMI BIOS
- IO chipset: ITE 8786
- System memory: 1x 204-pin DDR3L SO-DIMM socket, 2G
DDR3L (Default), support up to 8GB DDR3L-1333, Non-ECC
and un-buffered
- Storage Device: 1x 2.5” SATA HDD
- Watchdog timer: Watchdog timeout can be programmed by
software. from 1 second to 255 seconds and from 1 minute
to 255 minutes
(Tolerance 15% under room temperature 25°C)
- H/W status monitor: Monitoring system temperature, and
voltage
- Expansion: 1x mini-PCIe sockets
I/O
- Ethernet: 1x RJ45
- USB: 5 x USB 2.0
- Audio port: 2x Line out/built in speaker and microphone
- HDMI input connector
- Front touch icon
- 720p camera
Audio
- HDA codec: Realtek ALC886-GR
- Audio interface: Line out Audio Jack
Ethernet
- LAN chip: Intel® I210AT Gigabit LAN
- Ethernet interface: 10/100/1000 Based-Tx Ethernet
compatible
Wifi & BT (optional)
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
- Certified module BOINTE PE809-AA
- Support 802.11 b/g/n
- Support BT 4.0
Mechanical & Environment
- Color: white, pantone RAL9016
- Vibration:
IEC 68 2-64 (w/ HDD)
1Grms @ sine, 5~500Hz, 1hr/axis (HDD Operating)
- Shock:
IEC 68 2-27
HDD: 20G@panel mount, half sine, 11ms
- Operating temperature: 0°C to 40°C
- Storage temperature: -20°C to 60°C
- Operating/Storage humidity: 20%~80% relative humidity,
non-condensing
- The humidity preconditioning treatment is performed in a
humidity cabinet containing air with a relative humidity of
93%RH @25°C 48hrs
- Storage Altitude: up to 3000M
- Dimension: 417.2x 266.6x50 mm
- Weight: 4.5 Kg
- Power input: 100-240V~ 1.5-0.75A 50-60Hz
- Power Output: 19VDC, 4.74A
Certifications
- CE
- FCC class B
- EN60601-1
- UL60601-1
- IEC 60950-1 CB
- ANSI/AAMI ES60601-1*
- CAN/CSA-C22.2 No.60601-1*
* This panel pc incorporates the ES60601-1 /IEC60601-1 certified power supply,
Model MDS-090AAS19 B is by DELTA. The power supply is used in the
conditions of overvoltage category II, Pollution Degree II.
*This panel pc incorporates the power supply is Class II with functional earth
AC/DC Adapter intended for supplying medical electrical apparatus with two
parts of plastic enclosure fixed together by screws
Power Supply
- Model: DELTA MDS-090AAS19 B
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
JAO18
Overview
JAO 18 is designed to serve as a Point of Care (POC) and Point of
Information terminal (POI) within healthcare applications. Manufactured
using anti-bacterial plastics, the terminals provide a host of interactive
healthcare applications providing secure access to Electronic Medical
Records (EMR) and innovative triple-play solutions (web, IPTV, VoIP) for
patient entertainment.
Key Features
16:9 18.5” 1366x768 Fanless LED Panel Computer
Intel® Celeron® J1900, Quad Core, Low Consumption CPU
Flat Panel by PCAP Touch Screen
With 1x GbE/ HDMI input/ 5x USB ports
Built in speaker/ microphone/ 2x line out
13.56MHz RFID/ Smart card reader
DDR3L 2GB/ 2.5” 32GB SSD
System Power Input 19V DC
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Specification
Panel
- LED size: 18.5”, 16:9
- Resolution: 1366X768
- Luminance: 300 cd/m2
- Contrast ratio: 1000
- LED color: 16.7M
- Viewing Angle: 80(U) 80(D) 85(L) 85(R)
- Backlight: LED
Touch Screen
- PCAP touch
- Light transmission: 87%
- Interface: USB
System
- CPU: On-board Intel® Celeron® J1900, 2.0GHz,2M L2 Cache
- BIOS: AMI BIOS
- IO chipset: ITE 8786
- System memory: 1x 204-pin DDR3L SO-DIMM socket, 2G
DDR3L (Default), support up to 8GB DDR3L-1333, Non-ECC
and un-buffered
- Storage Device: 1x 2.5” SATA HDD
- Watchdog timer: Watchdog timeout can be programmed by
software. from 1 second to 255 seconds and from 1 minute
to 255 minutes
(Tolerance 15% under room temperature 25°C)
- H/W status monitor: Monitoring system temperature, and
voltage
- Expansion: 1x mini-PCIe sockets
I/O
- Ethernet: 1x RJ45
- USB: 5 x USB 2.0
- Audio port: 2x Line out/built in speaker and microphone
- HDMI input connector
- Front touch icon
- 720p camera
- Optional barcode scanner (IEC62471 certified)
Audio
- HDA codec: Realtek ALC886-GR
- Audio interface: Line out Audio Jack
Ethernet
- LAN chip: Intel® I210AT Gigabit LAN
- Ethernet interface: 10/100/1000 Based-Tx Ethernet
compatible
Wifi & BT (optional)
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
- Certified module BOINTE PE809-AA
- Support 802.11 b/g/n
- Support BT 4.0
- Power input: 100-240V~ 1.5-0.75A 50-60Hz
- Power Output: 19VDC, 4.74A
Mechanical & Environment
- Color: white, pantone RAL9016
- Vibration:
IEC 68 2-64 (w/ HDD)
1Grms @ sine, 5~500Hz, 1hr/axis (HDD Operating)
- Shock:
IEC 68 2-27
HDD: 20G@panel mount, half sine, 11ms
- Operating temperature: 0°C to 40°C
- Storage temperature: -20°C to 60°C
- Operating/Storage humidity: 20%~80% relative humidity,
non-condensing
- The humidity preconditioning treatment is performed in a
humidity cabinet containing air with a relative humidity of
93%RH @25°C 48hrs
- Storage Altitude: up to 3000M
- Dimension: 481.6x308.2x50 mm
- Weight: 4.7 Kg
Certifications
- CE
- FCC class B
- EN60601-1
- UL60601-1
- IEC 60950-1 CB
- ANSI/AAMI ES60601-1*
- CAN/CSA-C22.2 No.60601-1*
* This panel pc incorporates the ES60601-1 /IEC60601-1 certified power supply,
Model MDS-090AAS19 B is by DELTA. The power supply is used in the
conditions of overvoltage category II, Pollution Degree II.
*This panel pc incorporates the power supply is Class II with functional earth
AC/DC Adapter intended for supplying medical electrical apparatus with two
parts of plastic enclosure fixed together by screws
Power Supply
- Model: DELTA MDS-090AAS19 B
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
IO introduction
Front side
Camera
720p camera with white LED
RFID and smart card reader
13.56MHz RFID and smart card reader. RFID tag also readable
while parking in smart card reader slot
Power Key
Touch icon input. Long press 5 seconds to turn on panel
backlight; long press 10 seconds to reset or power off system.
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Back side
Microphone
Built in digital microphone
HDD service door
Lock with Torx screws, use for SSD replacement
Speaker
Built in stereo speaker
RAM and miniPCIe service door
Lock with Torx screws, use for RAM replacement or install
extension module
Rear IO
19V DC input
Service call
USB
LAN
connect to PSU
connect to back end service system (intra
network) with 4 wire signal pin
3x USB 2.0 ports
Gigabit Ethernet
Bottom IO
Line out
USB
HDMI
2x line out jack
2x USB 2.0 ports with 1.5A V
use as HDMI input
Barcode Scanner (optional)
Optional install 1D/2D supported barcode scanner module
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Mechanical Dimensions
JAO15
JAO18
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Jumpers and Connectors
This chapter describes how to set the jumpers and connectors on the
motherboard.
metal object. Static electricity can damage many of the electronic
components. Humid environments tend to have less static electricity than
dry environments. A grounding strap is warranted whenever danger of static
Before you Begin
Ensure you have a stable, clean working environment. Dust and dirt can get
into components and cause a malfunction. Use containers to keep small
components separated.
Adequate lighting and proper tools can prevent you from accidentally
damaging the internal components. Most of the procedures that follow
electricity exists.
Precautions
Computer components and electronic circuit boards can be damaged by
discharges of static electricity. Working on computers that are still
connected to a power supply can be extremely dangerous.
Follow the guidelines below to avoid damage to your computer or yourself:
require only a few simple tools, including the following:
Always disconnect the unit from the power outlet whenever you are
A Philips screwdriver
working inside the case.
A flat-tipped screwdriver
To fully disengage the power to the unit, please disconnect the power cord
A set of jewelers screwdrivers
from the AC inlet.
A grounding strap
If possible, wear a grounded wrist strap when you are working inside the
An anti-static pad
computer case. Alternatively, discharge any static electricity by touching the
Using your fingers can disconnect most of the connections. It is
bare metal chassis of the unit case, or the bare metal body of any other
recommended that you do not use needle-nosed pliers to disconnect
grounded appliance
connections as these can damage the soft metal or plastic parts of the
Hold electronic circuit boards by the edges only. Do not touch the
connectors.
components on the board unless it is necessary to do so. Don’t flex or stress
Before working on internal components, make sure that the power is off.
the circuit board.
Ground yourself before touching any internal components, by touching a
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Leave all components inside the static-proof packaging that they shipped
with until they are ready for installation. Use correct screws and do not over
tighten screws.
Jumper Setting
A jumper is the simplest kind of electric switch. It consists of two metal pins
and a cap. When setting the jumpers, ensure that the jumper caps are
placed on the correct pins. When the jumper cap is placed on both pins,
the jumper is short. If you remove the jumper cap, or place the jumper cap
on just one pin, the jumper is open.
Refer to the illustrations below for examples of what the 2-pin and 3-pin
jumpers look like when they are short (on) and open (off).
Two-Pin Jumpers: Open (Left) and Short (Right)
Three-Pin Jumpers: Pins 1 and 2 are Short
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Locations of the Jumpers and Connectors
Top View
Jumpers and DIP Switch Setting
CMOS Clear Select
Connector type: 1x3 3-pin header, 2.54mm pitch
Connector location: JBIOS1
Pin
Settings
1-2 ON
Normal
2-3 ON
Clear BIOS
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Connector Pin Definition
External I/O Interface
19V DC Power Input
HDMI Input Port
Connector type: 5.5mm DC jack
Connector type: HDMI Female connector
Pin
Definition
Pin
Definition
TMDS Data2+
11
TMDS Clock Shield
TMDS Data2 Shield
12
TMDS Clock–
TMDS Data2–
13
CEC
TMDS Data1+
14
N.C
TMDS Data1 Shield
15
SCL
TMDS Data1–
16
SDA
TMDS Data0+
17
DDC/CEC Ground
TMDS Data0 Shield
18
+5 V Power
TMDS Data0–
19
Hot Plug Detect
10
TMDS Clock+
REAR IO USB PORT
Connector type: USB type A female
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Service Call connector
USB
Connector type: 6 pin RJ 11 connector
Pin
Definition
VCC5
USB 0-
USB 0+
Pin
Definition
GND
Service call +
Service call -
Handset LED +
Handset LED -
Service call
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
LAN Ports
Connector type: RJ45 port with LEDs
ACT
Status
LINK
Status
Yellow blinking
Data activity
Steady green
1000M link
Off
No activity
Steady orange
100M link
Off
10M or no link
Pin
Definition
Pin
Definition
LAN M0+
LAN M2-
LAN M0-
LAN M1-
LAN M1+
LAN M3+
LAN M2+
LAN M3-
Pin
Definition
LOUT_R
JD
NC
LOUT_L
GND
GND
Line-out Jack
Connector type: 3.5mm Earphone Jack
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Internal Connectors
SATA
Connector location: SATA1
Pin
Signal
Pin
Signal
S1
GND
S2
SATA_TX0P
S3
SATA_TX0N
S4
GND
S5
SATA_RX0N
S6
SATA_RX0P
S7
GND
P1
VCC3
P2
VCC3
P3
VCC3
P4
GND
P5
GND
P6
GND
P7
VCC5
P8
VCC5
P9
VCC5
P10
GND
P11
NC
P12
GND
P13
VCC12
P14
VCC12
P15
VCC12
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Mini-PCIe Slot
Connector location: CN2
Pin
Signal
Pin
Signal
Pin
Signal
Pin
Signal
WAKE0#
3.3V_MINI
27
GND
28
+1.5V_MINI
NC
GND
29
GND
30
SMB_CLK
NC
1.5V_MINI
31
PCIE_TX3-
32
SMB_DAT
PCIE_CLKREQ
NC
33
PCIE_TX3+
34
GND
GND
10
NC
35
GND
36
USB-
11
GPP_CLK1-
12
NC
37
GND
38
USB+
13
GPP_CLK1+
14
NC
39
+3.3V_MINI
40
GND
15
GND
16
NC
41
+3.3V_MINI
42
NC
17
NC
18
GND
43
GND
44
NC
19
NC
20
MINICARD1_DIS#
45
NC
46
NC
21
GND
22
PCIE_RST#
47
NC
48
+1.5V_MINI
23
PCIE_RX2-
24
3.3V_MINI
49
NC
50
GND
25
PCIE_RX2+
26
GND
51
NC
52
+3.3V_MINI
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
System Setup
Prior to removing the chassis cover, make sure the unit’s power is off and
disconnected from the power sources to prevent electric shock or system
damage.
Replace SATA Disk
To fully disengage the power to the unit, please disconnect the power cord from
the AC inlet
1. Loose the screw of HDD service door.
2. Remove current SATA and replace with new one.
Avant de retirer le capot du châssis , assurez-vous que la puissance de
l'appareil est éteint et déconnecté de la source d'alimentation pour éviter
un choc électrique ou d'un système de dégâts.
Pour dégager pleinement la puissance à l'unité , s'il vous plaît débrancher
le cordon d'alimentation de la prise secteur
System setup and use in different environment. In normal use condition,
System button IO is toward to ground for better system performance. In
which means system usually install where panel face to user.
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
Replace RAM
1. Loose the screw of RAM service door.
2. Remove DDR3L RAM module and replace with new one.
3.
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.
Interactive Patient Care – Barco Healthcare Division
System Mounting
accessory pack, there are 4 M4 screws. Length of screw teeth should be
5mm. Screw should be fasten to back cover by 8KG torque.
There are different mount types to fix system in bracket or arm. In system
CONFIDENTIAL: The information contained herein is proprietary and confidential information of Barco. No part of the information contained herein may
be disclosed in any form or by any means and/or stored in a data base or retrieval system without the prior written consent of Barco and/or used for any
purpose other than authorized by Barco.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Extract
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Create Date                     : 2015:12:22 13:44:41+08:00
Creator Tool                    : PDFCreator Version 1.2.3
Modify Date                     : 2015:12:22 13:47:17+08:00
Metadata Date                   : 2015:12:22 13:47:17+08:00
Format                          : application/pdf
Description                     : 
Creator                         : annkuo
Title                           : 106B3A63
Keywords                        : 
Producer                        : GPL Ghostscript 9.04
Document ID                     : uuid:9d034e3d-55d0-4600-ab2b-d51f94eb2de8
Instance ID                     : uuid:68039773-26c9-41f1-b45e-6af0dca3e8a2
Page Count                      : 30
Subject                         : 
Author                          : annkuo
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SXE-JAO1801

Navigation menu