User’s Operating Instructions &
Important Warranty Information

Baxi Combi 133 HE Plus
Baxi Combi 100 HE Plus
Baxi Combi 80 HE Plus
Gas Fired Wall Mounted Condensing
Combination Boiler

Please keep these instructions in a safe place.
If you move house, please hand them over
to the next occupier.
© Baxi Heating UK Limited 2005

Natural Gas

Contents

Baxi Combi 133 HE Plus
G.C.No 47 075 14
Baxi Combi 100 HE Plus
G.C.No 47 075 15
Baxi Combi 80 HE Plus
G.C.No 47 075 16

Baxi is one of the leading manufacturers of domestic
heating products in the UK.

Our first priority is to give a high quality service to our
customers. Quality is designed into every Baxi product products which fulfil the demands and needs of customers,

Section

1.0

Quick Reference Guide

3

2.0

Troubleshooting

4

3.0

Repressurising

6

4.0

Clearances

7

5.0

Care of the Boiler

8

6.0

Legislation

9

7.0

Emergency

10

8.0

Warranty & Service

12

© Baxi Heating UK Limited 2005 All rights reserved. No part of this publication
may be reproduced or transmitted in any form or by any means, or stored in any
retrieval system of any nature (including in any database), in each case whether
electronic, mechanical, recording or otherwise, without the prior written
permission of the copyright owner, except for permitted fair dealing under
Copyrights, Designs and Patents Act 1988.
Applications for the copyright owner’s permission to reproduce or make other
use of any part of this publication should be made, giving details of the proposed
use, to the following address:

offering choice, efficiency and reliability.
The Company Secretary, Baxi Heating UK Limited, Pentagon House,
Sir Frank Whittle Road, Derby, DE21 4XA.

To keep ahead of changing trends, we have made a

Full acknowledgement of author and source must be given.

commitment to develop new ideas using the
latest technology - with the aim of continuing to

WARNING: Any person who does any unauthorised act in relation to a
copyright work may be liable to criminal prosecution and civil claims for damages.

make the products that customers want to buy.

Everyone who works at Baxi has a commitment to quality
because we know that satisfied customers mean continued
success.

We hope you get a satisfactory service from Baxi. If not,
please let us know.

Baxi supports

The code of practice for the
installation, commissioning &
servicing of central heating systems

This product has an energy rating (A) on a scale of A to G.
For more information see www.boilers.org.uk. This is a certification mark.

2

© Baxi Heating UK Limited 2005

Page

Baxi Heating UK Limited is a
BS-EN ISO 9001 Accredited Company

1.0 Quick Reference Guide

Key to Controls

ON

High
Low

Low

High

Domestic Hot Water
(Green Light)

This indicates that the Burner has fired up and heating your water.

Flame Failure
(Red Light)

If Flame Failure Light is ON press the Reset Button. If Flame Failure occurs
frequently consult your Installer.

Burner On
(Green Light)

This indicates that the Burner has fired up and is heating your system.

Mains On
(Green Light)

This indicates that there is electricity to the Boiler.

Domestic Hot Water
Control Knob
(No OFF Position)

Turn the Domestic Hot Water Control Knob clockwise to increase or
anticlockwise to decrease the temperature.

Reset Button

The Reset Button should extinguish the Flame Failure Light and allow
normal operation to commence.

Central Heating
Control Knob
(No OFF Position)

Turn the Central Heating Control Knob clockwise to increase or anticlockwise
to decrease the boiler flow temperature.

Domestic Hot Water Temperature Control
Turn the Domestic Hot Water Temperature Control
Knob clockwise to increase or anticlockwise to
decrease the temperature. Range 45 - 55° C.
Low

High

Reset

Central Heating Temperature Control
Turn the Central Heating Temperature Control Knob
clockwise to increase or anticlockwise to decrease
the boiler flow temperature.

ON

Low

High

Reset Button

Low

High

Reset

If the Red Flame Failure Light (
) is ON or
flashing, press the Reset button until the red light
goes OFF. If this occurs frequently a fault is indicated,
you should contact your installer.

ON

Low

© Baxi Heating UK Limited 2005

High

3

2.0 Troubleshooting

Boiler not working
START
YES

Is there electricity to the
boiler ? (Green Mains ON
Light lit).

YES

Make sure the gas
supply is turned ON
and check if other
gas appliances are
operating (e.g. fire,
cooker).

NO

Hig

Is the Green Burner ON
Light illuminated ?

NO

h
Hig

Low

h

Low

Rese

t

If no gas, consult
your supplier.

Reset

Burner ON Light
(Green)
Mains ON Light
(Green)

ON
ON

Hig

h
Hig

Low

h

Low

YES

NO
Check electrical supply to
boiler is switched on.

Is the Central Heating
System Pressure between
1 and 2.5 bar ?

YES

NO

Boiler operating
satisfactorily.

NO

Is the Red Flame Failure
Light illuminated or flashing ?

Hig

CONTACT YOUR
INSTALLER OR
SERVICE
ENGINEER.

h

Low

requires
repressurising

1

2
3

0

Pressure
Gauge

Flame Failure
(Red)

Reset

ON

If the reading falls below 1 bar
repressurise the system as
described in section 3.0.

Hig

h

Low

YES
Press the Reset Button
until the red light goes off.

Light ON
Light FLASHING
Light FLASHING

Boiler indicators
showing low
pressure

Low

High

Reset Button

Reset

ON

Low

4

© Baxi Heating UK Limited 2005

High

If the light
does not go
out or keeps
coming on

2.0 Troubleshooting

YES

Is the Timer ON and
calling for heat ?

Is the Room Thermostat (if
fitted) set high enough ?

YES

NO
12

1

11

10

2

15
10

25

5

9

3

8

4

5

7
6

Typical
examples of
external timers

20

CH OFF

CH ON

Turn Room Thermostat to
maximum setting (typical
example shown)
3

1

2

12

11

4

7

7

8

PM

9

5

10

8

AM
1 0

9

4

2 0

25

5

10

15

5

0
GRASSLIN

3

Optional
integral timer

2

1

12

11

NO
Ensure timer is set for Central
Heating ON (see any instructions
supplied with timer)

If you don’t know what you need to do
to get the boiler to light, or need help
with the system and controls, contact
your installer as soon as possible

© Baxi Heating UK Limited 2005

5

3.0 Repressurising System
3.1

1. The normal operating water pressure is in the green area
between 1 and 2.5 bar (Fig. 1). If the pressure exceeds 3 bar
the safety pressure valve will operate and a fault is indicated.
Contact your installer.

normal pressure

1

2
3

0

Central Heating System Pressure

2. It may be necessary to repressurise the system occasionally
(Fig. 2). A filling device (the ‘filling loop’) will be fitted on the
system. This may be on the boiler itself, or on pipework near
to the boiler.

Fig. 1

3. If you are unsure of its position, or cannot identify it, consult
the installer who fitted the boiler.

requires
repressurising

1
0

4. The filling loop consists of two taps and a separate metal
braided hose pipe (Fig. 3).

2
3

5. Only when repressurising should the hose be connected
between the two taps. No tools are necessary for this, but
ensure that the wing nuts on the hose pipe ends are tightened
onto the taps.

Fig. 2

6. Fully open one of the taps first, and then while watching the
pressure gauge, carefully open the second tap.
Copper Pipe

7. When the needle on the gauge is into the green zone and
indicating 1 (Fig. 1) or more turn both taps off.
8. Disconnect the hose from the taps (a small amount of water
may be present) and remove it. Keep the hose in a safe place
for future use.

Taps

Copper Pipe

Fig. 3 Typical Filling Loop
Wing Nut

6

© Baxi Heating UK Limited 2005

Hose

4.0 Clearances
490mm

5mm Min

5mm Min

200mm

4.1

For your Safety

1. This appliance must have been installed in accordance
with the manufacturer’s instructions and the regulations in
force.
2. Any modification that may interfere with the normal
operation of the appliance without express written
permission from the manufacturer or his agent could
invalidate the appliance warranty. In GB this could also
infringe the Gas Safety (Installation and Use) Regulations.
GB - Heating Industry definition meaning England, Scotland,
Wales, Northern Ireland, Isle of Man and the Channel Isles

850mm

3. Your boiler must not be operated without the casing
correctly fitted.
4. Do not interfere with any sealed components on this
boiler.
5. Take note of any warning labels on your boiler.

200mm

6. Your boiler should have the following minimum
clearances for Safety and Maintenance
(Figs. 4 & 5):Top
Bottom
Left side
Right Side
Front

Fig. 4

- 200mm
- 200mm
- 5mm
- 5mm
- 5mm (In Operation)
- 500mm (For Servicing)

7. If your boiler is installed in a compartment, do not use it
for storage purposes. Do not obstruct any purpose
provided ventilation openings.

3°
(1 in 20)

8. Flammable materials must not be stored in close
proximity to your boiler.
9. Avoid skin contact when your boiler is in operation, as
some surfaces may get hot e.g. pipework.
10. Ensure that the flue terminal outside the house does
not become damaged or obstructed, particularly by trees or
bushes.

500mm
For Servicing
Purposes

11. It is important that the condensate drain system is not
blocked, modified or damaged in any way as this would
affect the operation of your boiler. Your installer should
have insulated any exposed pipework.

5mm
Fig. 5

320mm

In Operation

© Baxi Heating UK Limited 2005

7

5.0 Care of the Boiler
5.1

Cleaning the Outercase

1. The painted panels should be wiped with a damp cloth
and then dried completely. DO NOT USE ABRASIVE
CLEANING AGENTS.

5.2

Protection & Precautions

1. The boiler incorporates an integral frost protection
feature that will operate in both modes. If the boiler
temperature falls below 4 °C, the boiler will fire until a
temperature of 15 °C is reached.
2. If a system frost thermostat has been fitted (your
Installer will be able to advise you), then to operate
correctly and protect your system, the gas and electricity
must be left on and the appliance set in the central
heating mode.
3. The boiler incorporates an integral pump protection
feature which continually monitors the time since the
pump last operated. To prevent seizure, the pump will
operate for approximately 1 minute if it has not run in the
last 24 hours.

8

© Baxi Heating UK Limited 2005

6.0 Legislation
6.1

Installation, Commissioning, Service &
Repair

1. This appliance must be installed in accordance with the
manufacturer’s instructions and the regulations in force.
Read the instructions fully before installing or using the
appliance.
2. In GB, this must be carried out by a competent person
as stated in the Gas Safety (Installation & Use) Regulations.
3. Definition of competence: A person who works for a
CORGI registered company and holding current
certificates in the relevant ACS modules, is deemed
competent.
4. In IE (Eire), this must be carried out by a competent
person as stated in I.S. 813 “Domestic Gas Installations”.

CORGI

Registered
Gas Installer
CARD SERIAL NO. 999999999

00000

All CORGI registered installers carry a CORGI
identification card (see Fig. 6) and have a registration
number. You can check your installer is registered by
telephoning 0870 4012300 or writing to:-

NAME:

A.N.Installer

1 Elmwood,
Chineham Business Park,
Crockford Lane,
Basingstoke. RG24 8WG

PH

OT
OG
R

AP

H

COMPANY:

Fig. 6

Newtown Heating
EXPIRES:

31 DECEMBER 2010

To confirm validity of this card please contact
CORGI on 0870

401 2300
www.corgi-group.com

CORGI Registration Card

or check online at www.corgi-gas-safety.com

The boiler meets the requirements of Statutory Instrument
“ The Boiler (Efficiency) Regulations 1993 No 3083” and is
deemed to meet the requirements of Directive 92/42/EEC
on the energy efficiency requirements for new hot water
boilers fired with liquid or gaseous fuels:Type test for purpose of Regulation 5 certified by:
Notified Body 0086.
Product/Production certified by:
Notified Body 0086.
Ref: 86-BL-647
For GB/IE only.

6.2

Benchmark Commissioning Check List

1. Please ensure that your installer hands you the boiler
Installation & Service Instructions with the “Benchmark”
Commissioning Checklist sections completed. The details
in the Checklist will be required in the event of any
warranty work. Keep the instructions in a safe place and
ensure that the Service Interval Record at the back is
completed at each service visit.

© Baxi Heating UK Limited 2005

9

7.0 Emergency

Warning !
If you smell gas
Turn off the gas supply at the meter and call your gas
supplier immediately. It is possible to isolate the boiler and
at the isolating valve (Fig. 7).
Transco operate a 24 hour emergency service and the
telephone number will be listed in your telephone
directory.

Faulty boiler

Tap

If it is known or suspected that a fault exists
on the boiler, it must not be used until the fault
has been corrected by a competent person.

In an Emergency
If a water or gas leak occurs or is suspected, the boiler can
be isolated at the taps under the boiler as follows;
1. Turn off the electrical supply to the boiler.
2. Using a suitable flat bladed screwdriver turn the tap on
the gas cock 90° clockwise to isolate the gas supply at the
boiler (Fig. 7).
3. The heating system and mains water isolating valves are
positioned under the boiler and can be closed by turning
their taps 90° clockwise (Fig. 7).
4. Call your Installer or Service Engineer as soon as
possible.

Fig. 7

10

Mains Water
Inlet

© Baxi Heating UK Limited 2005

Gas Cock

Heating Flow
and Return

Notes

© Baxi Heating UK Limited 2005

11

Please complete the boxes below

8.0 Warranty & Service
Serial Number

Standard Warranty Terms & Conditions
12 Months Free Warranty - register today
To receive your 12 months free warranty please complete the form supplied with
the boiler or simply call heateam, the service division of Baxi Heating UK Limited on
08706 000 653.
Our promise to you
If you experience a fault with your new boiler, we aim to provide a safe and high
quality repair service supported by our dedicated national network of highly skilled
engineers. If your installer can’t resolve the problem for you, we will do everything
we can to get an engineer out to you as quickly as possible. Nothing in this warranty
will affect your statutory consumer rights.

Date of Installation

D D M M Y Y
Installer Details (name, address and contact number(s)

What you need to do if you experience a problem with your heating system or
the operation of the boiler
You should always contact your installer first, because the fault may not be related to
the boiler. If your installer confirms that the fault is within the boiler itself and he/she
can’t repair it, our friendly customer service team is on hand to help. Simply call our
service division heateam on 08706 096 096 to book an engineer visit or for any
general advice that you may need. Our contact centre is open Monday to Friday
8am - 6pm, weekends and Bank Holidays 8.30am - 2pm, excluding Christmas Day
and New Years Day.
When calling heateam it would be helpful if you could have the following
information to hand:1
2
3
4

boiler serial number (see opposite).
boiler make and model number.
Your installer name and address details.
Proof of purchase (if you do not have the boiler
serial number).

What this warranty covers
Free of charge repair or replacement of components found to be faulty from
manufacture.
Free of charge replacement of the complete unit provided always that the failure is
related to a manufacturing fault that cannot be repaired or is uneconomic to repair.
The warranty runs for 12 months from the date your product is installed.
What this warranty does not cover
Repairs to boilers which haven’t been installed and commissioned properly, and as
set out out in the installation instructions (this includes the need to flush the system
effectively and add a suitable corrosion inhibitor).
Any damage caused by hard water scale deposits and/or aggressive water resulting
from corrosion.

Information Label

Any other defects or failures, either in the connected heating system or outside of
the boiler itself
Faults caused by an inadequate supply of electricity, gas or water to the property.
Installations within commercial settings for which this boiler was not designed.

All descriptions and illustrations provided in this leaflet have been carefully
prepared but we reserve the right to make changes and improvements in our
products which may affect the accuracy of the information contained in this

Reimbursement of any third party repair or replacement costs that we haven’t been
told about or agreed with you in advance.

leaflet. All goods are sold subject to our standard Conditions of Sale which are
available on request.

BAXI

Compensation for consequential losses (e.g. loss of earnings, business losses, stress
and inconvenience) arising from a product breakdown, including repair delays caused
by factors outside our reasonable control.

A Trading Division of Baxi Heating UK, a division of Baxi Group

Brooks House, Coventy Road, Warwick. CV34 4LL
After Sales Service 08706 096 096 Technical Enquiries 08706 049 049
Website www.baxi.co.uk
e&oe

© Baxi Heating UK Limited 2005

Annual Service
To ensure you receive the maximum efficiency from your boiler we recommend
your boiler has an annual service so you and your family can continue to enjoy
heating and hot water comfort. To arrange an annual service from one of our Baxi
Heating UK Limited heating experts, please call to arrange a visit convenient to you.
Comp No 5109930 - Iss 5 - 6/06



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 for Macintosh
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments
Modify Date                     : 2006:06:07 09:53:19+01:00
Creator Tool                    : QuarkXPress(tm) 6.5
Create Date                     : 2006:06:07 09:52:41Z
Format                          : application/pdf
Creator                         : Terry Sharples
Title                           : 5109930
Document ID                     : uuid:15f4f20a-f603-11da-8251-000393a1571e
Instance ID                     : uuid:15f4fac9-f603-11da-8251-000393a1571e
Page Count                      : 12
Author                          : Terry Sharples
EXIF Metadata provided by EXIF.tools

Navigation menu