Beckwith Electric M2911 DSS Universal Data Transceiver User Manual M 2911 SP 00
Beckwith Electric Co., Inc. DSS Universal Data Transceiver M 2911 SP 00
Contents
- 1. users manual
- 2. Exhibit D Users Manual per 2 1033 b3
users manual
CONTROLS BlueJay™ Universal Data Transceiver M-2911 • Provides direct sequence spread spectrum peer-to-peer, point-topoint, point-to-multipoint and master/slave high speed (1 Mbps) data transmission rates at ranges up to 1500 feet • Interfaces using either a RS-232, RS-422 or RS-485 connection at interface baud rates between 2400 and 115.2 Kbps • Substation hardened to withstand temperatures from -40 to +80 degrees C and humidity up to 95% • No user license required, interfaces with almost any legacy IED M-2911 BlueJay Universal Data Transceiver The M-2911 Blue Jay™ Universal Data Transceiver is a self-contained short-range wireless communication device (SRD) that is used for transferring serial communication data between Intelligent Electrical Device's (IED’s) and computers hosting control software in an industrial environment. The M-2911 is based on an Intersil direct sequence spread spectrum chip set that operates in the 2.4 GHz ISM band. The M-2911 design meets the category for low power devices (LPDs) standard requirement for license-free operation. Interface The M-2911 is equipped with two serial data connectors, one is a DE-9 connector for use with an RS-232 serial data port and the other is a 6-pin bare wire Phoenix–type connector for use with an RS-422/RS-485 (twisted shielded pair) serial data ports. Only one port can be used at a time. Each port is capable of serial data speeds of up to 115 kbps. Data Transmission: Error Detection – 16 bit CRC (10-5 BER at –70dBm) Maximum throughput – 1 Mbps RF, 2400 to 115.2 Kbps interface baud rate • • Communication The M-2911 conditions the data and transmits it over a half-duplex direct sequence spread spectrum radio operating in the 2.4 GHz ISM band. The over-the-air data rate is 1 Mbps. Transmit: • • • • • • • • Frequency Range – 2400 MHz to 2483.5 MHz Output Power – 30 mW Modulation – DBPSK Occupied Bandwidth – 20 MHz Spurious Emissions – 50 mV/meter Harmonic Emissions – 500 uV/meter Spreading Method – Direct Sequence 11 bit code Center Band – Carrier 2.450 GHz Receive: • • Sensitivity – -93 dBm Selectivity – 25 MHz ■ NOTE: For maximum range, all antennae must be oriented in the same plane. Power The M-2911 includes a self-contained switching power supply that supplies the data and RF circuitry with regulated dc power as required. The power supply has an external 3.5 mm outside diameter, 2.1 mm inside pin, center positive power input jack designed to accept the output of a UL listed wall transformer power supply included with each unit that delivers between 7 and 60 V dc at a maximum power output of 2.5 Watts. Power Requirements: • • • • • Operating Voltage – +7 to +60 V dc Transmit Current – 2 W (300 mA @ 7 V) Receive Current – 2 W (300 mA @ 7 V) Inlet Current – 1 W (150 mA @ 7 V) Sleep Current – 0.2 W (30 mA @ 7 V) –3– M-2911 BlueJay Universal Data Transceiver Configuration The M-2911 is configurable with the following parameters: • • • • • • • • • • • Unit (Transmit/Receive) Address: 1 to 250 Destination (Transmit): 1 to 255 Multicast (Receive) Address: 251 to 254 Baud Rate: Selectable from 2400 to 115,200 Parity: Even/Odd/No Parity Transmit Retry: 0 to 9 times Interface: RS-232/RS-422/RS-485 RS-232 RTS/CTS: FIXED/AUTO/FLOW-THRU RS-422/485 Tx: Gating: 0 to 10 characters Lead Time: 0 to 10 mS Hold Time: 0 to 10 mS Intercharacter Timeout: 1 to 10 character times/1 to 100 mS Maximum Packet Size: 1 to 60 characters Configuring the M-2911 To configure the M-2911, the unit must be put in the AT-Command Mode. To put the unit in AT-Command Mode: 1. Connect the unit (using an RS-232 cable) to a PC or laptop computer running a terminal emulator program (such as Microsoft HyperTerminal) set to 9600 bps, No Parity, One Stop Bit. 2. Apply power to the unit. 3. After 1–2 seconds, type "+++", and pause for 1 second or more. The M-2911 will enter AT-Command Mode and respond with "OK". The user can then enter any of the AT Commands listed below. ■ NOTE: After each command, the unit will return "OK" if the command was valid, or "???" if invalid or outof-range. AT Commands Unit (Transmit/Receive) Address Configuration: ATS=nnn, where nnn is 1 to 250 Destination (Transmit) Address Configuration: ATD=nnn , where nnn is 1 to 255 Multicast (Receive) Address Configuration: ATM=nnn , where nnn is 251 to 254 Baud Rate Select: ATB=nnnnnn , where nnnnnn is 2400, 4800, 9600, 19200, 38400, 76800, or 115200 Parity Select: ATP=x, where x is E for Even Parity, O for Odd Parity, or N for No Parity Transmit Retries Configuration: ATR=n , where nn is 0 to 9 Interface Selection: RS-232, RS-422, or RS-485 ATI=RS232 ATI=RS422 ATI=RS485 RS-232 RST Configuration: ATI=RTSx , where x is 0 for Low, 1 for High, F for Flow-Thru ATI=CTSx , where x is 0 for Ignore, 1 for Obey, F for Flow-Thru –4– M-2911 BlueJay Universal Data Transceiver RS-422 Tx Gating Configuration: ATI=TXO , to set Transmit On. ATI=TXLnC , to set Transmit On Lead Time to n characters ATI=TXHnC , to set Transmit On Hold Time to n characters ATI=TXLnnn , to set Transmit On Lead Time to nnn mS ATI=TXHnnn , to set Transmit On Hold Time to nnn mS Intercharacter Timeout Configuration: ATT=nnC , where nn is1–10 ATT=nnn , where nnn is 1–1,000 for 1 mS to 1000 mS Maximum Packet Size Configuration: ATN=nn , where nn is 1–52 View Settings: ATV ; the command returns the following (example) parameters: Beckwith Electric M-2911 BlueJay Transceiver Software Version 01.00 Serial Number: 001.032 Unit Address: 001, Destination Address: 002, Multicast Address: 251 Baud Rate: 9600 bps, No Parity Transmit Retry: 5 RS-232, RTS Flow-Thru, DTR Flow-Thru, DSR Flow-Thru Intercharacter Timeout: 5 Char, Maximum Packet Size: 32 Char Exit AT-Command Mode: ATZ Application Information Circuit Signal DB-9S RS-232 BB RX Receive Data Pin 2 BA TX Transmit Data Pin 3 CA RTS Request to Send Pin 7 CB CTS Clear to Send CD DTR Data Terminal Ready CF DCD Data Carrier Detect AB GND Signal Ground Table 1 RS-232 Communication Port Signals –5– Pin 4 Pin 5 M-2911 BlueJay Universal Data Transceiver RS-232 Communication M-2911 DB9S PC DB9P RX TX SGND RTS CTS Figure 1 RX TX SGND RTS CTS RS-232 Pin-out RS-232 is point-to-point (four wires plus shield) from M-2911 to one IED. RS-422 Communication M-2911 6 Pin Terminal Block P1 SGND DRX D+ DTX D+ SGND RS-422 Connection Shielded Twisted Pair Figure 2 RS-422 Pin-out –6– SGND D - TX D+ DRX D+ SGND M-2911 BlueJay Universal Data Transceiver RS-422 is a dual shielded, twisted pair (four wires plus two shields), from M-2911 to one IED. M-2911 RS-422 SGND DRX D+ DTX D+ SGND 200 IED 200 Figure 3 RS-422 Example IED RS-422 network is a dual shielded twisted pair (four wires plus two shields), from M-2911 to IEDs in parallel. IED's In Parallel M-2911 RS-422 SGND DRX D+ DTX D+ SGND 200 IED IED 200 Figure 4 RS-422 Network Example IED's in Parallel –7– M-2911 BlueJay Universal Data Transceiver RS-485 Communication M-2911 6 Pin Terminal Block P1 RS-485 Network 1 SGND 2 D3 D+ SGND DD+ N/C N/C N/C Figure 5 RS-485 Pin-out RS-485 is a single shielded twisted pair (two wires plus shield), from M-2911 to IEDs in parallel. IED's In Parallel M-2911 RS-485 SGND DRX/TX D+ N/C N/C N/C 200 IED IED 200 Figure 6 RS-485 Example IED's in Parallel –8– M-2911 BlueJay Universal Data Transceiver 1.00 3.88 1.50 4.51 3.38 .25 TX RX P WR 3.62 (2X) 3.08 5.50 M-2911 WIRELESS CONVERTER BECKWIT H 1.15 CO. INC. EL ECT RIC .93 (2X) Ma d e i n U.S .A . .20 DIA (4X) .56 2.75 Figure 7 Outline Dimensions –9– .38 M-2911 BlueJay Universal Data Transceiver Environmental Temperature: Proper operation maintained from –40°C to +80°C. Storage Temperature: –50°C to +100°C. Humidity: Proper operation is maintained up to 95% relative humidity (non-condensing). Environmental Protection: The power supply printed circuit board is conformally coated to inhibit fungus growth. Enclosure: 1/16" Aluminum. Physical Size: 5.88" high (with antenna 9.43") x 3.88" wide x 2.5" deep (14.58 cm (23.1) x 9.9 cm x 6.13 cm). See Figure 7 for dimensional drawing. Weight: 2.13 oz (60 grams) Enclosure meets requirements of IP30. Safety and Cautions 8 WARNING: The installation, maintenance, and/or operation of this equipment could present potentially unsafe conditions, including, but not limited to, electrical shock or improper voltage to components. Improper operation could cause personal injury, death, or damage to property. Read all safety instructions before operating the M-2911, and retain them for further reference. Follow all operating and usage instructions, and make special note of the following safety symbols: – This sign warns that the area is connected to a dangerous high voltage, and you must never touch it. – This sign means that you should refer to the corresponding section of the operation manual for important information before proceeding. Do not attempt to perform maintenance or service functions that are not described in the operating instructions. Instead, refer all such service requirements to Beckwith Electric Co., Inc. Unit must be returned for service in secure (preferably original) packaging. Shipping cost must be paid by user. Only the antenna provided is authorized for use with the M-2911. If the antenna is lost or damaged, please contact Beckwith Electric Co., Inc. to secure a replacement antenna. This product generates, uses, and can radiate radio frequency (RF). If it is not installed and used in accordance with the operating instructions, it can cause harmful interference to communications. If this equipment causes harmful interference to radio or television reception, the user should try and correct the interference by: • Reorienting or relocating the receiving/transmitting antenna • Increasing the separation between the equipment and the M-2911 • Connecting the equipment into an outlet on a different circuit from the M-2911. If these do not correct the interference, consult an experienced radio/television technician for assistance. Correcting such interference is the responsibility of the user, not the manufacturer. –10– M-2911 BlueJay Universal Data Transceiver Compliance This device has been designed to operate with an antenna having a maximum gain of 2 dB. Antenna having a higher gain are strictly prohibited per regulations of Industry Canada. The required antenna impedance is 50 ohms. This equipment has been tested and found to comply with the limites for a Class A digital device, pursuant to Part 15.247 and 15.109 of the FCC Rules and Industry Canada RSS-210 and ICES-003. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Patent & Warranty ■ NOTE: Changes or modifications to the unit not expressly approved by Beckwith Electric Co. may void the user's authority to operate the equipment. U.S. Patent for the M-2911 BlueJay™ Universal Data Transceiver is pending. The M-2911 BlueJay™ Universal Data Transceiver is covered by a five year warranty from the date of shipment. Specification is subject to change without notice. –11– IS 94 19 01 red te O egis BECKWITH ELECTRIC CO., INC. 6190 - 118th Avenue North • Largo, Florida 33773-3724 U.S.A. PHONE (727) 544-2326 • FAX (727) 546-0121 E-MAIL marketing@beckwithelectric.com WEB PAGE www.beckwithelectric.com © 2002 Beckwith Electric Printed in U.S.A. (08.30.02) 800-2911-SP-00MC1 11/02
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Modify, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Create Date : 2002:10:15 18:36:44Z Modify Date : 2002:11:06 15:33:24-05:00 Subject : M-2911 SP-00 Page Count : 12 Creation Date : 2002:10:15 18:36:44Z Mod Date : 2002:11:06 11:42:41-05:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : SStanley Keywords : Metadata Date : 2002:11:06 11:42:41-05:00 Creator : SStanley Title : M-2911 SP-00 Description : M-2911 SP-00EXIF Metadata provided by EXIF.tools