Behringer Ultra Di Pro Di4000 Users Manual

Behringer-Ultra-Di-Pro-Di4000-Owners-Manual behringer-ultra-di-pro-di4000-owners-manual

Behringer DI4000 User Manual DI4000_M_EN Behringer - DI4000 - User Manual

Behringer DI4000 User Manual di4000_m_en Behringer - DI4000 - User Manual

DI4000 to the manual 1f7d0f08-2464-4067-993c-ea517457f6cb

Behringer DI4000 User Manual di4000_m_en Behringer - DI4000 - User Manual

2015-06-29

: Behringer Behringer-Ultra-Di-Pro-Di4000-Users-Manual-751986 behringer-ultra-di-pro-di4000-users-manual-751986 behringer pdf

Open the PDF directly: View PDF PDF.
Page Count: 9

User Manual
ULTRA-DI PRO DI4000
Professional 4-Channel Active DI-Box
2ULTRA-DI PRO DI4000 User Manual
Table of Contents
Important Safety Instructions ...................................... 3
Legal Disclaimer ............................................................. 3
Limited warranty ............................................................ 3
1. Introduction ............................................................... 4
1.1 Before you begin ................................................................. 4
1.2 Online registration ............................................................. 4
1.3 Control elements ................................................................ 5
2. Applications ............................................................... 5
2.1 Tapping signal from a (bass) guitar .............................. 5
2.2 Converting the output of a keyboard / DJ-mixer /
headphone plug ......................................................................... 5
2.3 Converting a microphone signal .................................. 6
2.4 Tapping a signal from a power amplieroutput .... 6
3. Installation ................................................................. 6
3.1 Rack mounting ..................................................................... 6
3.2 Mains connection .............................................................. 6
3.3 Audio connections ............................................................. 6
4. Specications ............................................................. 8
3ULTRA-DI PRO DI4000 User Manual
Important Safety
Instructions
LEGAL DISCLAIMER
LIMITED WARRANTY
Terminals marked with this symbol carry
electrical current of su cient magnitude
to constitute risk of electric shock.
Use only high-quality professional speaker cables with
¼" TS or twist-locking plugs pre-installed. Allother
installation or modi cation should be performed only
by quali edpersonnel.
This symbol, wherever it appears,
alertsyou to the presence of uninsulated
dangerous voltage inside the
enclosure-voltage that may be su cient to constitute a
risk ofshock.
This symbol, wherever it appears,
alertsyou to important operating and
maintenance instructions in the
accompanying literature. Please read the manual.
Caution
To reduce the risk of electric shock, donot
remove the top cover (or the rear section).
No user serviceable parts inside. Refer servicing to
quali ed personnel.
Caution
To reduce the risk of  re or electric shock,
do not expose this appliance to rain and
moisture. The apparatus shall not be exposed to dripping
or splashing liquids and no objects  lled with liquids,
suchas vases, shall be placed on the apparatus.
Caution
These service instructions are for use
by quali ed service personnel only.
Toreduce the risk of electric shock do not perform any
servicing other than that contained in the operation
instructions. Repairs have to be performed by quali ed
servicepersonnel.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in
accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as
radiators, heat registers, stoves, or other apparatus
(including ampli ers) that produce heat.
9. Do not defeat the safety purpose of the polarized
or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding-type plug
has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. Ifthe
provided plug does not  t into your outlet, consult an
electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or
pinched particularly at plugs, convenience receptacles,
and the point where they exit from the apparatus.
11. Use only attachments/accessories speci ed by
themanufacturer.
12. Use only with the
cart, stand, tripod, bracket,
or table speci ed by the
manufacturer, orsold with
the apparatus. When a cart
is used, use caution when
moving the cart/apparatus
combination to avoid
injury from tip-over.
13. Unplug this apparatus during lightning storms or
when unused for long periods of time.
14. Refer all servicing to quali ed service personnel.
Servicing is required when the apparatus has been
damaged in any way, such as power supply cord or plug
is damaged, liquid has been spilled or objects have fallen
into the apparatus, the apparatus has been exposed
to rain or moisture, does not operate normally, or has
beendropped.
15. The apparatus shall be connected to a MAINS socket
outlet with a protective earthing connection.
16. Where the MAINS plug or an appliance coupler is
used as the disconnect device, the disconnect device shall
remain readily operable.
TECHNICAL SPECIFICATIONS AND APPEARANCES
ARE SUBJECT TO CHANGE WITHOUT NOTICE AND
ACCURACY IS NOT GUARANTEED. BEHRINGER,
KLARKTEKNIK, MIDAS, BUGERA, AND TURBOSOUND
ARE PART OF THE MUSIC GROUP MUSICGROUP.COM.
ALL TRADEMARKS ARE THE PROPERTY OF THEIR
RESPECTIVE OWNERS. MUSICGROUP ACCEPTS NO
LIABILITY FOR ANY LOSS WHICH MAY BE SUFFERED
BY ANY PERSON WHO RELIES EITHER WHOLLY OR
IN PART UPON ANY DESCRIPTION, PHOTOGRAPH
OR STATEMENT CONTAINED HEREIN. COLORS AND
SPECIFICATIONS MAY VARY FROM ACTUAL PRODUCT.
MUSIC GROUP PRODUCTS ARE SOLD THROUGH
AUTHORIZED FULLFILLERS AND RESELLERS ONLY.
FULLFILLERSAND RESELLERS ARE NOT AGENTS OF
MUSICGROUP AND HAVE ABSOLUTELY NO AUTHORITY
TO BIND MUSICGROUP BY ANY EXPRESS OR IMPLIED
UNDERTAKING OR REPRESENTATION. THIS MANUAL
IS COPYRIGHTED. NO PART OF THIS MANUAL MAY
BE REPRODUCED OR TRANSMITTED IN ANY FORM
OR BY ANY MEANS, ELECTRONIC OR MECHANICAL,
INCLUDING PHOTOCOPYING AND RECORDING OF ANY
KIND, FOR ANY PURPOSE, WITHOUT THE EXPRESS
WRITTEN PERMISSION OF MUSICGROUPIPLTD.
ALL RIGHTS RESERVED.
© 2013 MUSICGroupIPLtd.
Trident Chambers, Wickhams Cay, P.O. Box 146,
Road Town, Tortola, British Virgin Islands
For the applicable warranty terms and conditions
and additional information regarding MUSIC Group’s
Limited Warranty, please see complete details online at
www.music-group.com/warranty.
4ULTRA-DI PRO DI4000 User Manual
1. Introduction
Whether you are on the stage or in the studio, you often nd that you need
to connect an audio source to your mixing console, but you don’t have the
appropriate connectors. For example, only few keyboards feature balanced
outputs; guitars should not be connected directly to the console; and placing
a microphone in front of an amp is not always an ideal solution, because the
mic will pick up unwanted signals from other instruments, too. Low frequency
signals (e.g. produced by a bass guitar) are particularly dicult to handle using
thesetechniques.
“DI” is short for “Direct Injection”. A Direct Inject box allows you to use a
high-impedance, unbalanced source, e.g. the signal between guitar and guitar
amp, and feed it directly into an input channel on your console, withouthaving
to use a microphone. And thats far from being all. There are plenty of situations
in which youd like to input unbalanced source signals into your console,
andpossibly convert them to balanced signals before. As you can expect,
theDI4000 oers you a reliable solution.
The following explanations will give you an introduction to the complex
performance-impedance issue: impedance is dened as the dependence
of a device’s electrical resistance and phase response on the frequency
processed. Thus, impedance is one of the criteria that distinguish good DI
boxes from poor ones. Much like in a power amp and its connected speakers,
impedancedetermines the performance of the device. With a good power
amp, the load impedance will have little inuence on the maximum output
power, butit can considerably aect other properties. With a passive DI
box, the connected load impedances (ins and outs) alter the bandwidth,
frequencyresponse, distortion, etc. of the DI box.
By the way: there are two basic types of DI boxes, passive and active. Bothcan
be connected to one of the console’s mic inputs. Passive DI boxes oer the
advantage that they are less expensive than active models (less electronics,
no power supply), however, their performance depends on the connected
impedance. With a passive DI box connected, any impedance change on the
console side will also modify the input impedance. The frequency response
will always depend on the impedances connected. Any passive DI box will only
perform properly with accurately specied impedances (high on the input side,
low at the output), i.e. it will only work in standard situations.
Active DI boxes such as our ULTRA-DI PRO, however, do not suer from such
restrictions, because they use an amplier circuit to buer the input signal.
Sincethe ULTRA-DI PRO’s input impedance is ultra-high, the signal remains
unaected as it passes through the DI box. Additionally, the ULTRA-DI PRO
features balanced impedances on the output side, making the signal less
susceptible to hum and noise interference. In this way, the signal as source
impedance is completely independent of the console used (and vice versa),
whichmeans that the sound remains totally unaected. The ULTRA-DI PRO uses
our proven OT-1 transformer which ensures a clear and distortion-free sound and
linear frequency response. Additionally, the ULTRA-DI PRO comes with a built-in
power supply.
Future-oriented BEHRINGER technology
The ULTRA-DI PRO is based on SMD technology (Surface Mounted Devices).
Thesesubminiature components known from aerospace applications ensure both
extreme packing density and greater reliability.
High-quality components and design
The philosophy behind BEHRINGER products guarantees a no-compromise circuit
design and employs the best choice of components. The op-amps, type 4580,
used in the ULTRA-DI PRO are chosen for their superior signal-to-noise ratio,
lowdistortion and linear performance. Additionally, the ULTRA-DI PRO uses high
quality resistors and capacitors with very tight tolerances, high-grade switches
as well as other selected components.
This manual first describes the terminology used, so that you can fully
understand the ULTRA‑DI PRO and its functions. Please read the manual
carefully and keep it for future reference.
1.1 Before you begin
Your BEHRINGER ULTRA-DI PRO was carefully packed in the factory and
the packaging was designed to protect the unit from rough handling.
Nevertheless,werecommend that you carefully examine the packaging and its
contents for any signs of physical damage, which may have occurred in transit.
If the unit is damaged, please do not return it to us, but notify your
dealer and the shipping company immediately, otherwise claims for
damage or replacement may not be granted. Shipping claims must be
made by the consignee.
The BEHRINGER ULTRA-DI PRO ts into one standard 19" rack unit of space.
Pleaseallow at least an additional 4" (10 cm) depth for the connectors on the
back panel.
Be sure that there is enough space around the unit for cooling and
please do not place the ULTRADI PRO on high temperature devices such
as power amplifiers etc. to avoid overheating.
The mains connection of the ULTRA-DI PRO is made by using the supplied cable.
Itmeets all of the international safety certication requirements. Please make
sure that all units have a proper ground connection.
Before you connect your ULTRA‑DI PRO to the mains, please make sure
that your local voltage matches the voltage required by the unit!
1.2 Online registration
Please register your new BEHRINGER equipment right after your purchase
by visiting http://behringer.com and read the terms and conditions of our
warrantycarefully.
Should your BEHRINGER product malfunction, it is our intention to have it
repaired as quickly as possible. To arrange for warranty service, please contact
the BEHRINGER retailer from whom the equipment was purchased. Shouldyour
BEHRINGER dealer not be located in your vicinity, you may directly contact
one of our subsidiaries. Corresponding contact information is included in the
original equipment packaging (Global Contact Information/European Contact
Information). Should your country not be listed, please contact the distributor
nearest you. A list of distributors can be found in the support area of our website
(http://behringer.com).
Registering your purchase and equipment with us helps us process your repair
claims more quickly and eciently.
Thank you for your cooperation!
5ULTRA-DI PRO DI4000 User Manual
1.3 Control elements
The BEHRINGER ULTRA-DI PRO has four identical channels. The control elements
are identical on all channels.
(6) (7)
(2) (4)(1) (3) (5)
Fig. 1.1: Control and display elements on the front panel
(1) OUTPUT. This is the balanced output of the ULTRA-DI PRO. The connection
to the mixing desk should be made with a standard high-quality
balancedcable.
(2) +20 dB gain switch for pre-amplication of low level signals.
(3) Switchable HIGH CUT lters (8 kHz) for guitar applications (6 dB/Oct).
(4) With the PHASE REVERSE switch the input signal is reversed in phase
by180°.
(5) Use the GND LIFT switch to either connect the ground of input and output
or keep them completely separate. Depending on the grounding of the
connected devices linking or disconnecting will reduce hum or prevent
ground loops. GROUND LIFT on means no interconnection.
(6) The OUTPUT LEVEL meter displays the output level of the Ultra-DI PRO in a
range from -24dB to +18dB.
(7) Use the POWER switch to turn on the BEHRINGER ULTRA-DI PRO.
(11)(12)(13)
(10)(8) (9)
Fig. 1.2: Rear panel elements of the BEHRINGER Ultra-DI PRO
(8) LINK. This is the unbalanced parallel output of the ULTRA-DI PRO.
Connectthis to the input of the backline or monitor amplier.
(9) INPUT. Connect the source to this ¼" jack to input the signal.
(10) and (13) The -20 dB ATTENUATION switches greatly increase the operating
range of the ULTRA-DI PRO. From the low level signals of a high impedance
guitar to the hot speaker terminals of a PA amplier. Depressingboth will
give 40 dB attenuation.
Only use the ‑20 dB switches if you are sure the Ultra‑DI PRO is
clipping (overloading) and not your mic pre‑amp. Always use as little
attenuation as possible to get the best possible signal‑to‑noise ratio.
(11) FUSE HOLDER/VOLTAGE SELECTOR. Please make sure that the voltage
indicated on the unit matches your local voltage, before you attempt to
connect and operate the VINTAGER AC112. Blown fuses may only be replaced
by fuses of the same type and rating. Some models allow for inserting the
fuse holder in two dierent positions, in order to switch over from 230 V
to 115 V operation, and vice versa. Please note that for 115 V operation
outside Europe, you need to use a fuse of a higher rating (see chapter3
“Installation”). Use the enclosed power cord to connect the unit to themains.
(12) To provide maximum exibility the ULTRA-DI PRO is also tted with an
unbalanced XLRINPUT to connect the source.
2. Applications
2.1 Tapping signal from a (bass) guitar
Microphone Input
Out
DI4000
In Link Out
Fig. 2.1: Guitar DI box Guitar Amp/Mixer
This gure shows the standard application of any Direct Inject box. The signal to
the amplier is unaected, it is just tapped o to be routed to the microphone
input of the mixer. Especially bass guitars benet from this application. It is
dicult to nd a microphone which handles high level low frequencies well and
with a linear frequency response. Using the ULTRA-DI PRO will give you clean and
crisp sound. Connect the ULTRA-DIPRO after any eects devices, so that their
eect will be heard over the PA system or on the recording.
2.2 Converting the output of a keyboard /
DJ-mixer / headphone plug
Out OutIn In
Microphone Inputs Pan left and right
Fig. 2.2: DJ-mixer 2 x DI box mixer
6ULTRA-DI PRO DI4000 User Manual
This conguration can be used with a keyboard, DJ-mixer, headphone output,
drum kit or any (stereo or mono) line source. In all cases where you want to run
long lines, for instance to the FOH (Front Of House) desk. The signal can be linked
through to another amplier, if the keyboard player/ DJ/etc. wants to have a
monitor connected independent of the foldback mix. The ULTRA-DI PRO acts as
both a ground isolator and an unbalanced to balanced converter.
2.3 Converting a microphone signal
OutIn
Fig. 2.3: Connecting a microphone
Sometimes all thats available (especially when all other mics are in use) is an
unbalanced high impedance microphone with an unbalanced jack. With the
ULTRA-DI PRO long cable runs to the console can be established without fear
of picking up noise and hum. Just plug the jack into the input and connect the
output to the console’s mic input.
2.4 Tapping a signal from a power
amplieroutput
When no line out is available it is possible to connect an amplier output directly
to the DI4000 (for example, recording direct from a guitar amplier, TV-speaker,
etc). It is possible to connect the output, i.e. an extra speaker output, of up to
3000 Watts to the ULTRA-DI PRO without fear of overloading. Pay attention to the
two -20 dB buttons on the ULTRA-DI PRO! Both must be depressed if an amplier
output is connected to the DI4000 input.
In
Out
+red or positive post
-black or negative post
-20 / -40 dB!
Fig. 2.4: Connection to an amplier output
Always make sure the GROUND LIFT is on (no ground link)
when connecting to speaker terminals. This prevents accidental
short‑circuiting of the amplifier output. Also make sure the tip of the
input jack is connected to the red terminal and that the metal housing
of the DI4000 has no contact with other equipment.
3. Installation
Your BEHRINGER ULTRA-DI PRO was carefully packed in the factory and
the packaging was designed to protect the unit from rough handling.
Nevertheless,werecommend that you carefully examine the packaging and its
contents for any signs of physical damage, which may have occurred in transit.
If the unit is damaged, please do not return it to us, but notify your
dealer and the shipping company immediately, otherwise claims for
damage or replacement may not be granted. Shipping claims must be
made by the consignee.
3.1 Rack mounting
The BEHRINGER ULTRA-DI PRO ts into one standard 19" rack unit of space.
Pleaseallow at least an additional 4" depth for the connectors on the back panel.
Be sure that there is enough air space around the unit for cooling and
please do not place the ULTRA‑DI PRO on high temperature devices such
as power amplifiers etc. to avoid overheating.
3.2 Mains connection
The mains connection of the ULTRA-DI PRO is made by using a mains cable
and a standard IEC receptacle. It meets all of the international safety
certicationrequirements.
Please make sure that all units have a proper ground connection.
For your own safety, it is advisable not to remove the ground
connection within the units or at the supply, or fail to make this
connection at all.
Before you switch on the unit, check that it is congured to match your AC
mains voltage requirements. If it does not comply, then it is necessary to switch
the operating voltage to the correct supply requirements BEFORE turning on
the unit, otherwise the unit could be severely damaged. You will nd this
combined fuse holder/voltage selector at the back, adjacent to the IEC receptacle.
IMPORTANT:This does not apply for general export models which are
built for one operating voltage only.
The AC voltage selection is dened by the position of the fuse holder. If you
intend to change the operating voltage, remove the fuse holder and twist it
by 180 degrees before you reinsert it. Matching the two markers shows the
selectedvoltage.
If the unit is switched to another operating voltage, the fuse rating
must be changed. See the technical specifications in the appendix.
A safety fuse protects the unit from serious defects. If the fuse blows, this is a
warning sign and always indicates that the circuit is overloaded. The fault must
always be repaired before the fuse is replaced. If the safety fuse is faulty and
needs replacing after the unit is repaired, please make sure that you replace it
only with the identical type and rating. NEVER use fuses of dierent ratings or
cover faulty fuses with aluminium foil. This can cause re and electric shocks and
will endanger your life and the lives of others.
3.3 Audio connections
As standard, the BEHRINGER ULTRA-DI PRO is installed with transformer-
balanced outputs. This transformer features automatic hum and noise
reduction for balanced signals and thus allows for trouble-free operation,
even at high operating levels. Externally induced mains hum etc. will be
eectivelysuppressed.
Please ensure that only qualified persons install and operate the
ULTRA‑DI PRO. During installation and operation the user must have
sufficient electrical contact to earth. Electrostatic charges might affect
the operation of the ULTRA‑DI PRO!
7ULTRA-DI PRO DI4000 User Manual
Pin 1
tupnIelbaCtuptuO
Pin 2 = (+) Signal
Positive
Pin 3 = (-) Signal
Shield
(+) Signal + Hum
(-) Signal + Hum
Negative
(+) Hum + Signal
(-) Hum + Signal
2 x Signal
Ground
RFI and Hum
= Signal + 6 dB
12
3
12
3
Fig. 3.1: Compensation of interference with balanced connections
strain relief clamp
sleeve
tip
sleeve
(ground/shield)
Unbalanced use of mono ¼" jack plugs
tip
(signal) output
For unbalanced use, pin 1 and pin 3
have to be bridged
1 = ground/shield
2 = hot (+ve)
3 = cold (-ve)
input
12
3
12
3
Balanced use with XLR connectors
Fig. 3.2: Dierent plug types
strain relief clamp
sleeve
ring
tip
sleeve
ground/shield
For connection of balanced and unbalanced plugs,
ring and sleeve have to be bridged at the stereo plug.
Balanced use of stereo ¼" jack plugs
ring
cold (-ve)
tip
hot (+ve)
8ULTRA-DI PRO DI4000 User Manual
4. Specications
Audio Input
Connectors XLR and ¼" jack
Type DC-decoupled, unbalanced input
Impedance max. 220 kOhm
Max. input level +20/+40/+60 dBu
Audio Output
Connectors XLR
Type transformer-balanced output stage
Impedance 600 Ohms balanced
Max. output level +20dBu
System Specications
Bandwidth (100 kOhm) 23Hz to 120 kHz (±3 dB)
Bandwidth (600 Ohm) 23Hz to 27 kHz (±3 dB)
Bandwidth (High Cut) 10 Hz to 8 kHz (±3 dB)
Noise -95 dBu
Power Supply
Mains Voltages
USA/Canada 120 V~, 60Hz
U.K./Australia 240 V~, 50Hz
Europe 230 V~, 50Hz
General export model 100 - 120 V~, 200 - 240 V~, 50 - 60Hz
Power consumption max. 10 Watts
Fuse 100 - 120 V~: T 200 mA H
200 - 240 V~: T 100 mA H
Mains connection standard IEC receptacle
Physical
Dimension 1 ¾ x 19 x 8 ½"
44.5 x 483 x 215 mm
Net weight 5.9 lbs / 2.7 kg
Shipping weight 7.9 lbs / 3.6 kg
BEHRINGER is constantly striving to maintain the highest professional standards. As a result of these efforts,
modifications may be made from time to time to existing products without prior notice. Specifications and
appearance may differ from those listed or illustrated.
We Hear You

Navigation menu