Beijing InHand Networks Technology Co IR6X5WAP Industrial Cellular Router User Manual

Beijing InHand Networks Technology Co,. Ltd. Industrial Cellular Router

Contents

User manual

                                              InRouter 6X5 Series     Compact Design: 4 Ethernet LAN switch ports, RS232/485 (DB9), Wi-Fi (2.4GHz 802.11b/g/n),3G/UMTS or Ethernet WAN connection Power supply: 9-26V DC Power Terminal   High security: Advanced VPN (IPSec/SSL/GRE/L2TP/PPTP) Centralized management platform: InHand Device Manager Cloud Reliable for almost all industrial conditions Smart 4 Ethernet LAN/Wi-Fi/ Serial to Ethernet WAN/HSPA+/UMTS Router Overview InRouter6X5  series  are  compact designed industrial  cellular  routers which can help users to quickly access  to high-speed Internet and support secure and reliable data transmission. The products combine together with the functions of unmanaged switch, serial server, 3G Router, IP modem, Advanced VPN client and even WIFI and provide with high cost-effective solution for  applications  in  industrial automation  and  control, fleet  monitoring,  video  surveillance,  advertising  media,  and  outlets networking. You can even configure it easily through the browser on your IOS or Android terminals without connection to the router by cable.   Besides flexibility, InRouter6X5 series can provide reliable data link. For example, the multi-level linkage detection ensures linkage stability especially for applications in unattended areas. The outstanding performance under wide temperature and harsh electromagnetic field enables the capability to work under harsh conditions.   The most amazing thing is InRouter6x5 support almost the VPN security protocols which only exist in advanced VPN Routers. It is compatible with the major VPN routers including the brands of Cisco, HuaWei, Juniper etc. Specification Interfaces WAN Interfaces Ethernet WAN: Static IP/PPPoE/DHCP Client Cellular WAN: HSPA+: 21Mbps (DL)/5.76Mbps (UL) GSM/GPRS/EDGE: 850/900/1800/1900 MHz UMTS /HSPA/HSPA+: 850/900/1900/2100 MHz   Authentication: CHAP/PAP/MS-CHAP/MS-CHAPV2 LAN Interfaces Auto Adaption: 4 10M/100M Ethernet ports, auto-adaptive   MDI/MDI-X auto crossover Isolation Protection: 1.5KV isolation protection Power supply 9-26V DC 5.08mm 2pin Terminal power supply Serial ports Number: 1 RS232/RS485 DB9 Protocol: Modbus RTU, Transparent TCP, Virtual COM     Wi-Fi (Optional)   Environmental Operating temperature: -20°C~70°C Storage temperature:-40°C ~85°C Humidity: 5%~95%, no-condensing Protection grade: IP40  EMC  ESD: EN61000-4-2     Surge: EN61000-4-5   EFT: EN61000-4-4        RF: EN61000-4-3   RC: EN61000-4-6          Oscillatory Wave Immunity: EN61000-4-12   Variation Magnetic Field Immunity: EN61000-4-8  Safety   Anti-shock:IEC60068-2-27   Anti-drop: IEC60068-2-32   Anti-vibration: IEC60068-2-6
                                              Wireless: 150Mbps 802.11b/g/n Work mode: AP/Client   Authentication:open,WEP,WPA/WPA-2(Personal),PA/WPA2(Enterprise) Firewall security service     State Packet Inspection, anti-DoS attacks, Filter multicast     Filter ping, Access control list    Configuration DB9 Console port, Telnet, and Web configuration  Upgrade Remote  upgrade  and  web  upgrade,  utilizing  redundant  backup mechanism for worry-free upgrade Network Function Network Address Translation (NAT) and Port Address Translation (PAT) Deny illegitimate host access  Reliable Network Link Built-in hardware watchdog, self-recovery PPP link detection disaster self-recovery Professional upgrades mechanism, assure upgrade safety TCP/IP Protocols ICMP, IP, TCP, UDP, DHCP, PPP, ARP, Telnet, DNS, VRRP, HTTP, HTTPS, VPN (IPSec/SSL/PPTP/L2TP/GRE) Installation Optional Wall mounting kits or DIN mounting Kits  Warranty Warranty Period: 1 year, for more period please contact InHand sales Dimensions (Unit: mm) Side View Front View Back View DB9 RS232 /RS485 Port RS232 RS485 Device Manager Cloud
            FCC STATEMENT   1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:   (1) This device may not cause harmful interference.   (2)  This  device  must  accept  any  interference  received,  including  interference  that  may  cause undesired operation.   2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.   NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,  pursuant  to  Part  15  of  the  FCC  Rules.  These  limits are  designed  to  provide  reasonable protection against harmful interference in a residential installation.   This equipment generates uses and can radiate radio frequency energy and, if not installed and used in  accordance  with  the  instructions,  may  cause  harmful  interference  to  radio  communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one Model IR6x5 Part Number IR6<X>5-<N>-<P>-<S> X (Option VPN) 0: no VPN;   1: standard VPN (IPSec/PPTP/L2TP/GRE);   9: advanced VPN(IPSec/PPTP/L2TP/GRE/OpenVPN) + X.509 CA support    N (Network) UE00: No wireless module WH01: UMTS/HSDPA (850/900/1900/2100 MHz) VZ16:CDMA2000 EVDO\1X( 800MHz/1900MHz/2100MHz) VZ01: EVDO(800MHz/1900MHz. for China/India only) PH01:HSPA+ (850/900/1900/2100 MHz) S (Serial port) <NA> : RS232 485 : RS485 Example IR6 1 5 WH01-AP: Standard VPN (IPSec/PPTP/L2TP/GRE)   WH01: UMTS/HSDPA (850/900/1900/2100 MHz)   Wi-Fi : AP mode   RS232 serial port Order Information FCC Warning Statement
  Connecting Devices, Enabling Services info@inhandnetworks.com or more of the following measures:       Reorient or relocate the receiving antenna.       Increase the separation between the equipment and receiver.       Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.       Consult the dealer or an experienced radio/TV technician for help.   FCC Radiation Exposure Statement   This  equipment  complies  with  FCC  radiation  exposure  limits  set  forth  for  an  uncontrolled environment.  This  equipment  should  be  installed  and  operated  with  minimum  distance  20cm between the radiator & your body

Navigation menu