Beijing Quanyong Manufacture and Trade YK-500 Flash Spike Strip Remote Control User Manual English

Beijing Quanyong Manufacture & Trade Co.,Ltd. Flash Spike Strip Remote Control English

User Manual

Index
. Safe usage of
Product
01
. Product
introduction 02
. Deployment &
Launch 03
. Reloading Strips 06
. Maintain Used
Strips 11
. Maintenance Tips 13
. FAQ 15
. Performance Index 17
1. Safe usage of product
Thank you for using Flash Spike Strip. Our product is the safest and the
first design of electronic remote control & automatic mechanical ejection
tactical equipment. It brings success and safety to Operator in stop
chasing tasks when facing the high speed wild running car near the road.
For users benefit, please also carefully read over below safety
instructions before using the product to safely use our product and
guarantee the success of your task.
Please dont stand in front of launch hatch door of suitcase when using the
product.
Operators first maintenance task need to be under supervisor of experienced
engineer.
During maintenance task, please switch off the power before you refill strips
into suitcase.
During maintenance task, please avoid touching pole hook lock or turn pole
hook handle
after you locked it done and before you completely refill it into suitcase.
During maintenance task, please pay attention to sharp spike and strip
self-expansion when
folding it. Please wear gloves if required.
Product has complex circuit inside suitcase, please avoid throwing or swing
it in the task.
Product function problem can only be repaired by qualified engineer.
2. Product introduction
3. Deployment & Launch
Deployment
i. Put the suitcase aside the road with control panel facing outside of road. Adjust launching hatch door of suitcase
(with mark FLASH SPIKE STRIP or CAR INTERCEPTOR) to face the road inside vertically. See below diagram please.
ii. Switch on the power clockwise in the left side of control panel. The system light in the center of control
panel should start blinking in every 5 seconds. It indicates system has been started. See below diagram please.
iii. Please pick up either of Mini remote control or Hand-held STOP remote control from top side of suitcase and
walk to safe/tactical location to get ready for tasks. Please test status of wireless connection with system by
pressing Button A. The status light on both sides of suitcase should start blinking then please press Button B
to stop wireless connection testing. If the status light is not on after pressing Button A, please extend antenna
of remote control or walk near to the system until it can receive signal properly.
After go through above steps, now the system has been deployed and is ready for launch. It can be on standby at
least 720 hours until the system has no juice.
05
Flash Spike Strip
Launch
i. If the chasing or suspect is coming soon, please open the safety of system by pressing button C
of remote control.
ii. Once operator see car chasing or suspect, press button D right away and the system will launch
strip spike and block off the entire road within 2 seconds.
Note: At Launch steps above, in some special cases such like missing remote control, battery has no juice etc. , operator can also manually switch
on
emergency switch
clockwise in the right side of panel of suitcase to launch strip spike to block off the road immediately after power is on. We
d
highly recommend operator never let this happen because anyone who gets close to the road is very dangerous in stopping chasing tasks.
Flash Spike Strip
4. Reloading Strips
i. Switch off the power of system by turning power switch anticlockwise on the left side of the control
panel. The system light in the center of control panel should be off now. PLEASE ALWAYS REMEMBER TO SWITCH
OFF THE POWER BEFORE YOU RELOADING STRIPS INTO THE SUITCASE. See diagram below please:
ii. The door of launch hatch of suitcase should be open now after just finished task. If its not or operator
accidentally closed it, operator can also switch on emergency switch clockwise on the right panel of suitcase
to open the door of launch hatch.See diagram below please:
Flash Spike Strip
iii. Slowly plug in strip spike into suitcase by pushing pole hook until spring bolts automatically locks
the strips. See diagram below please:
iv. Pull out pole hook by below stepsa) Push pole hook lock ahead until its end (about 5 CM)
b) Turn pole hook handle from horizontal to vertical 90 degree c) Then operator can pull pole hook from strip
away d) Close the launch hatch door of suitcase e) put pole hook back
ii. Two people walk towards by one foot hold edge of strips to fold.
iii. Stay put to hold strips until iv. Make pole hook chain the pole hook lock it done. backbone of strips through
13
Flash Spike Strip
v. run hooks socket through vi. Press down pole hook cap
screw cap one by one until last to fasten one end
vii. While one hand keep pressing down the pole hook cap, another hand
turn pole hook handle on the other side from vertical 90 degree to 180
degree (a complete horizontal line). Then pole hook lock will automatically
lock the strips(you will hear click when it automatically locks strips).
6. Maintenance Tips
The system has 4 D cells in cell box and it can be on standby for at least 720 hours for ready to launch.
It has 5 power lights to indicate the power of cell. The light will become off one by one as the mark of decreasing
power. Please change the 4 D cells at the appropriate time. The system has two remote controls. One is built
as mini remote control shape and another is built as hand-held STOP shape so it will meet both requirements of
normal highway patrol asking pull over and SWAT hidden interceptor tasks. There is a built-in 23A-12V cell in
mini remote control. Please replace it at appropriate time. The hand-held STOP remote control has a built-in
charge battery and flashlight function. Please charge it at appropriate time. Suitcase top can prevent rain water
but please avoid water flood into suitcase because the product has complex circuit inside the suitcase. Operator
should test this system at least once each year to make sure its in a good for use status. If operator is not
going to use the system for a long period of time, please take the cell out of cell box on the side of suitcase.
When first using this system, operator needs to do some practice in case they make wrong operation in real task.
The delivery package of product come with 4 strips and 40 spikes free spare parts. It can be used for at least
5 tasks. After using up spare parts, customer needs to buy spare parts from distributor. Please contact distributor
for support of spare parts pack.
7. FAQ
Q Root Cause Solution
1. Operator didnt turn power
switch enough to appropriate
position.
1. Turn power switch to right
position.
2. There is no cell in cell box
or the cell is in wrong
direction of + and -.
2. Load the cells into cell
box, please pay attention to
the direction of + and of
cell.
After switching on the
power, the power light
is still off.
3. The cell has no juice. 3. Change the cell.
4. Bad contact between cells.
4. Reload the cells into cell
box and check each contact
point.
After switching on the
1. Press the button not hard
enough. The light on remote
control is not on.
1. Press the button hard until
you see the light on remote
control is on.
power, the power light
is on but the system is
not r e s p on d i n g t
o r e mo t e
2. The cell in remote control
has no juice. 2. change a new 23A-12V cell.
controls signal. 3. The remote control and the
system is too far away.
3. Keep the distance between
remote control and the system
in the scope of 100m.
1. Please exactly follow the
1. Operator didnt keep the strip guide and picture to reload spike
horizontally when aiming it the strip spike into hatch of with door of hatch
system.
2. After vehicle runs over Not smoothly when operator reloading strip spike
into the hatch. The strip spike will break strip spike, operator need to after
ejected.
2. After stopping vehicle tasks, change damaged part if there operator
didnt replace the is any before reloading it into damaged part with new
one. hatch of system. The standard configuration of strip is total 4 pieces.
8. Performance index of flash spike strip
Width of interception: 8m Max remote control working scope: 100m Length of steel spike: 4.5cm Dimension: 620mm
x 450mm x 200mm Response/Deployment time: < 2 seconds Voltage: 6v (4*1.5v D-cell) Weight: 21kg Spare Parts: 4
strips/ 40 Spikes
After plugging in explosive part by customer
Weight of pressure for triggering explosive part: 200 KG Equivalent of explosion: 0.2 kg TNT Blast effect: Detonate
and overturn target car with suicide bombing
POSTOFFICE BOX 3508,PINGGU DISTRICT, BEIJING, CHINA ZIPCODE: 101213 TELEPHONE: +86 138 1708 2752/ +86 010 6091 8162 FAX: +86 010 6091 8186 Web:
www.quanyong.com.cn E-mail: xuebing.tang@gmail.com xuebingtang@hotmail.com quanyong888@sina.com
Flash Spike Strip
MSN: xuebingtang@hotmail.com
FCC warning statement
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modications to this device not explicitly approved by
manufacturer could void your authority
RF warning statement:
The device has been evaluated to meet general RF exposure requirement. The device can
be used in portable exposure condition without restriction.

Navigation menu