Belter Health Measurement and Analysis Technology ETE-68B4 Infra-red Ear Thermometer User Manual

Shenzhen Belter Health Measurement and Analysis Technology Co., Ltd. Infra-red Ear Thermometer

User manual

1  ETE-68B4 Infra-red Ear Thermometer
2  Edition:A0 Thank  you  for  choosing  Belter  Infrared  ear  thermometer.  The  product  combined  the newest technology and had passed related certification test.With its unique technology ,it can get stable and accurate measurement result every time.This product will self test and display  the  current  room  temperature  when  starting  up  to  ensure  the  accuracy  of  the measurement.   This  product  is suitable  for home  or hospital to  measure  and  monitor  human  body    temperature,and suitable for people of all ages. Measurement site of this product :auditory meatus
3   Key of symbols symbol Description   WARNING WARNING indicates a hazardous situation which, if not avoided, could Result in death or serious injury   CAUTION CAUTION indicates a hazardous situation which, if not avoided, may result in minor or moderate injury  NOTICE addresses practices not related to personal injury, such as product and/or property damage     Type BF                 Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary  This item is compliant with Medical Device Directive 93/42/EEC of June 14,1993, a directive of the European Economic community  Refer to instruction manual / booklet IP22 Degree of protection against harmful ingress of particulate matter and water.  Manufacturer         Authorized representative in the European Community            Date of manufacture          Serial number   WARNING     NOTICE
4  Do not judge you own body state according to if you have fever or not. If you worry about your health , please consult a physician  Do not dispose of electrical appliances as unsorted municipal waste, use separate collection  facilities.  Contact  you  local  government  for  information  regarding  the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.  The device is not suitable for use in the presence of flammable anesthetic mixtures with air or with oxygen or nitrous oxide.  The device requires no calibration.  The device is not repairable and contains no user serviceable parts.  No modification of this equipment is allowed.    Remove batteries if equipment is not likely to be used for some time.  The user must check that the equipment functions safely and see that it is in proper working condition before being used.  The manufacturer does not require such preventive inspections by other persons. The ear thermometer is used only for testing, it cannot replace a doctor. Please do not use the thermometer in other ways except measure body temperature, if it is used for children please observe the general safety precautions. Please do not dismantle, re-assemble or drop the ear thermometer. The  ear  thermometer  temperature  sensing  head  protective  cover  or  other components should keep away from children. Incorrect usage of battery may cause damage, please do not re-charge, dismantle   the battery or throw the battery into fire, please deal with the battery according to local related regulations . Please don't operate the product out of operating conditions or out of the operating temperature range .It may cause measurement value anomaly or malfunction Please don’t bite, throw, folding ,pull and strong impact the device .Or it may cause a failure Please don’t measuret if have auricle inflammation or otitis media .Or it may aggravate inflammation
5    CAUTION Please  do  not  dip  the  device  into  water  or  other  liquid  Cleaning  and  disinfecting please follow(cleaning and storage) section in the manual Keep  the  device  from  sunshine,  and  store  in  dust  free,  dry,  store  temperature  of -20℃-+55℃(-4℉-+131℉)areas . If the sensor or product is broken, please do not use. If the device is broken, please do not repair it by yourself, contact with your nearest customer service.   Left ear wax can cause measurement of low temperature phenomenon ,so please make sure the ear is clean to ensure accurate measurement result.   Before  measurement  please  make  sure  the  sensor  mirror  is  clean  .If  there’s  any dirt,please clean it with alcohol cotton swab before use. The  device  is  made  of  precision  parts.  Do  not  drop  it,and  protect  it  from  strong impact .Please don’t twist the device or sensor. Please  clean  the  thermometer  sensor  after  use  ,  to  ensure  the  measurement accurancy and avoid cross-infection. Please don't add any protective sleeve to the sensor, or the measurement result will be incorrect please make sure the device appearance is not damaged and the sensing head is not dirty before use.If there is any breakage ,please don’t use .Damage and smudginess may cause incorrect measurement result.   CAUTION Please read the manual carefully before use, and keep it in safe place. To make sure the measurement result is accurate, please wait at least 30 seconds after measuring every time, then you can measure again. After cleaning the inductive head with alcohol, the device should be kept for a few minutes  till  the  alcohol  volatilize,and  the  inductive  head  back  to  natural temperature.Usually the suggested time is 5 minutes, otherwise the result may be incorrect. Because  baby's  temperature  adjustment  ability  has  not  been  perfect,  if  the environment  temperature  changed  sharply,  do  not  use  the  device  test  baby's temperature,  the  result  may  be  incorrect.  Wait  a  few  minutes  in  the  same environment till the baby's temperature become stable.
6  When testing ,suggest test in the same ear, because the temperature of left and right ear is different. The following situations should test three times, and use the highest one: 1) baby who born in 100 days. 2) Baby under 3 years, the baby whose immune system has defects, User who use the device in the first time,    before he is familiar with the device and get the stable temperature reading. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant  to  part  15  of  the  FCC  rules.  These  limits  are  designed  to provide  reasonable  protection  against  harmful  interference  in  a  residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference  to  radio  communications.  However,  there  is  no  guarantee  that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio  or  television reception, which can be  determined  by turning  the  equipment  off  and  on,  the  user  is  encouraged  to  try  to  correct  the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This  device  complies  with  part  15  of  the  FCC  rules.  Operation  is  subject  to  the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. RF Exposure The  equipment  complies  with  FCC  radiation  exposure  limits  set  forth  for  an uncontrolled  environment.  This  device  should  be  installed  and  operated  with minimum distance 0mm between the radiator & your body. SPECIFICATIONS
7  Item NO.   TE-68B4 Test site ear test range 34.0℃-43.0℃ measurement accuracy ±0.2℃ (36℃≤t<39) ;      ±0.3℃other range Use environment 16℃ ~ 40℃   <95%RH temperature division   0.1℃/0.1℉ indicator or fever alarm buzzer“bi-bi” information storage store the latest 10 group test data before turn off unit shift ℃/℉ Automatic off approx. 60's after use storage and transport condition -20℃ - +55℃(-4℉-+131℉) storage environment humility 15%RH-90%RH power supply 2 x AAA battery life time 5000 times low battery indicator Below DC2.5V±0.1V clinical allow maximum error margin This product pass clinical verification, the clinical maximum allowable error is 0.3 bluetooth function Bluetooth 4.0 transmission, android and apple 4.0. Body temperature A person’s normal temperature range tends to decrease with age. The following table shows normal ThermoScan ranges by age. Normal ThermoScan ranges by age :   0 –   2 years        97.5 – 100.4 °F        36.4 – 38.0 °C   3 –   10 years      97.0 – 100.0 °F        36.1 – 37.8 °C 11 –  65 years      96.6 – 99.7 °F          35.9 – 37.6 °C   >        65 years      96.4 – 99.5 °F          35.8 – 37.5 °C The normal temperature range will change between different people and different time in a day.So make sure you and your family member's normal temperature is very important .you can use this product to observe you and your family normal temperature range easily.
8   Operating Information:    1.Protect a set 2.Probe membrane 3.battery cover 4.Scan/M button 5.LCD 6.ON/OFF button   Operating instructions:   Open the battery cover, place two AAA batteries according to the indication sign in the battery case, and take off the protection cover on the head.   CAUTION Protective  cover  is  used only when  storing  ,you  must  take  down protective  cover  when measuring. 2、Press the "ON/OFF" button and the device start self calibration,all symbols (picture A) will display on the LCD with buzzing about one second.Picture B is detecting the measuring head temperature,when it displays "0000"(picture C), the device is ready for testing.                        A                   B                  C 3、pull the ear, and keep the ear straight.                         3 1 2 4 5 6
9  A, Baby under 1 year should pull the ear back-forward.    B, baby older than 1 year and adult should pull                                                                    up-back forward. 5、Insert the temperature sensing head into the ear canal,and combine closely to make sure to measure accurate ear temperature. 6、Move out the device, and the temperature will display on LCD.  7、Wait 30 second, and then start next test. 8、If no operation in 60 second, the device will shut off automatically.   CAUTION Please donn’t touch the heat detection , also don't let’s impact .otherwise it will cause measurement value anomaly or malfunction . The left ear canal and the right ear readings may be different  ,so please measure in the     same ear canal. .Accurate temperature can be measured only if there is no obstruction and no excessive accumulation of ear wax in the ear   .The ear temperature may be high if you lie on the side and one ear is compressed,so after going to bed please do not measure in the ear which is compressed on the side .If you want to measure after eating ,doing sports and going out ,please have a rest for thirty minutes to avoid inaccurate measurement result .Repeated measure:If want to measure again you should wait for a minute. .The ear thermometer is appropriate in measuring the temperature of human body ear   canal, compared with the common clinical thermometer, it measures principle and diagraph part all different, as a result is not likely to acquire same measured value. .The ear thermometer is a kind of high –tech and high sensitive thermometer. So it’s very   high request    for    operating environment and measuring a method when using. And easy to cause the    measurement not correct due to human operate not the ear thermometer problem , please read the instructions carefully before use
10  The correct method    to insert in the ear canal                                    Before measuring ,please confirm the direction of the ear canal. Human ear canal is not straight will bend with increased age   Opposite the ear tympanic membrane, gently pull back, it is easy to tympanic membrane direction The correct measurement method to measuring others   When measuring the ear temperature for adults or children, please clearly see the ear canal, then deep into as much as possible When measuring    the ear temperature for active child, please put    one hand on the other side to make sure    the head  is not rotation,after you clearly see the ear canal, then deep into as much as possible When measuring the ear temperature for sleeping baby.Please make sure the ear up (let face in a horizontal position), with one hand holds the head to avoid head rotation When the ear is small cann’t insert , the tympanic direction just plug into the ear canal Check the memory and delete the memory data. 1、The latest test data will be saved before shut off, and 10 memories can be kept mostly. 2、Press "Scan/M" button when the device is off,    the latest test data will display.  3、Press"Scan/M" button continuously can check all the saved data. 4、If the saved data more than 10 groups, the first one will be deleted. Unit shift 1、Press "Scan/M" and "ON/OFF" buttons the same time when the device is off to enter Unit Exactitude Inaccuracy
11  shift mode. 2、Press "Scan/M" button can change the unit.          3、press "ON/OFF" to finish unit shift. 4.After completing the measurement , please pack the protective cover and store it in required environment. Cleaning instructions:   1、  Sensitive head is the most important part of the device, and the front mirror is fragile. The sensitive dead can be cleaned with cotton swab or soft cloth with alcohol / warm water 2、  Clean LCD and cover with clean soft cloth, do not use solvent, do not dip into water or other liquid. 3、Please cover protective cover if don't use, avoid dust pollution and direct sunlight .storage the thermometer environmental conditions should maintain relative stability, had better be in 16-35, humidity is not more than 90% RH environment, so it is easy to use at any time   Description  of  maintenance  and  who  should  do  it:  Please  hande  it  over  to  a professional personnel to carry on maintaining   Storage instructions: Please pack good protective sleeve in the collection bag if don’t use the thermometer.If it is not installed protective sleeve state custody, it may cause a malfunction Please make sure the thermometer , collection bag and protective sleeve out of the reach of the baby, otherwise may cause failure Please don’t    put the thermometer into the collection bag storage when it’s wet.Or it may cause a failure . please do not place the device in too high/low temperature and humility environment, to avoid sunshine, keep away from electric shock and dusty environment.
12  Please keep the device in dry environment, and the temperature should be -20℃- +55℃. Please do not put this product in condition which exceeds above required storage and transportation conditions. . Take out the batteries if the device will not be used for long time, in case the battery may destroy the device. Replacing the batteries 1.When voltage of  the batteries is  low ,the lcd will display “ ”symbol,please    place two  new  batteries  in  unit  .the  Infra-red  Ear  Thermometer  can  not  work  accurately under the condition of low voltage. 2.The Infra-red Ear Thermometer is supplied with “AAA”DC1.5V×2PCS 3.remove the battery cover and take out old batteries  4.place two new batteries according to the “+”or”-“ 5.please take out the batteries to avoid battery leaking if the unit is not used for over six months     Instructions on how to safely dispose of the device:     Batteries should be disposed of separately from household waste. Always dispose of batteries as per your local regulations. Again, do not dispose of batteries with normal household waste.   Observe the local regulations for material disposal. Dispose of the device in accordance with  local  regulations.  If  you  have  any  questions,  please  contact  the  local  authorities responsible for waste disposal.   Instructions on accessories:   . battery  :AAA×2PCS Instruction manual      1 PCS . Infrared ear thermometer    1PCS  Troubleshooting Information: sign Possible Reason solution  when the temperature is lower than 32.0℃, LCD display "L" check whether the sensitive head mirror is broken or dirt  when the temperature is higher than 42.9℃, the LCD check whether the sensitive head mirror broken or dirt
13  display "H"  when the environment temperature is out of the device working temperature range move the device into suitable temperature environment, keep about 30 minutes and then test.  low power change the battery  no display 1)  the device shut off 2)  the  battery  doesn't install correctly 3)  battery has no power 4)  no display on LCD 1)  press  "ON/OFF"  turn on 2)  check  whether  the battery  is  installed correctly 3)  change the battery 4)  contact with seller CLASSIFICATION 1. Internally powered equipment; 2. Type BF applied part: Probe;   3. IP22; 4. Not category AP / APG equipment; 5. Mode of operation: continuous operation. Additional Information: non-toxic, No Stimulation, No sensitization adverse reaction for user during test.   Disease and self-care information: The device has been calibrated before delivery, if you use it according to manual instruction, there is no need to calibrate .If there's any question regarding to test, please contact with professional person (our company) Be subjected to vibration of the strong row such as the product, outside the dint function is damaged or the measurement result have problem, please do not use, please contact with my company. If the product    suffer strong vibration, damage or have query about the measurement results.Please do not use, please contact with our company.   Warranty:
14  if you use the device according to the manual, replace it within 3 months and guarantee for free a year. The following situations are not included in warranty time: 1)  problem caused by self dismounting 2)  problem caused by shocking during use or delivery. 3)  problem caused by incorrect maintenance 4)  problem caused by incorrect operating, problems caused by unprofessional repair. . supply the purchase prove when require warranty. the repair will be charged if not in warranty period or range . we keep the final explanation right for above warranty. User Assistance Information:   ShenZhen Belter Health Measurement and Analysis Technology Co.,ltd 702/704, Block  C, Tsinghua  Unis Science Park,  No.13 Langshan Rd,  Hi-Tech Industrial Park(north), Nanshan District, 518057 Shenzhen, People’s Republic of China E-mail:belter@belterhealth.com   Postal code:518057  20XX-XX