BioMerieux 416030 TOMGUARD LABGUARD 3 IS USED TO MEASURE AND CONTROL PHYSICAL PARAMETERS IN LABORATORY SUCH AS TEMPERATURE, HUMIDITY, CO2, ETC. User Manual Quick start guide

bioMerieux S.A. TOMGUARD LABGUARD 3 IS USED TO MEASURE AND CONTROL PHYSICAL PARAMETERS IN LABORATORY SUCH AS TEMPERATURE, HUMIDITY, CO2, ETC. Quick start guide

User Manual

Download: BioMerieux 416030 TOMGUARD LABGUARD 3 IS USED TO MEASURE AND CONTROL PHYSICAL PARAMETERS IN LABORATORY SUCH AS TEMPERATURE, HUMIDITY, CO2, ETC. User Manual Quick start guide
Mirror Download [FCC.gov]BioMerieux 416030 TOMGUARD LABGUARD 3 IS USED TO MEASURE AND CONTROL PHYSICAL PARAMETERS IN LABORATORY SUCH AS TEMPERATURE, HUMIDITY, CO2, ETC. User Manual Quick start guide
Document ID2158356
Application IDWcZqK3MariAysZic0q07vw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize308.76kB (3859526 bits)
Date Submitted2014-01-06 00:00:00
Date Available2014-01-06 00:00:00
Creation Date2013-12-24 10:57:24
Producing SoftwareAntenna House PDF Output Library 6.0.396 (Windows)
Document Lastmod2013-12-24 10:57:24
Document TitleQuick start guide
Document CreatorAH XSL Formatter V6.0 MR8 for Windows : 6.0.9.10681 (2013/04/23 18:22JST)

Intentionally left blank.
Document history
VERSION
DATE
05/11/2013
MODIFICATIONS
Creation
User manual - Pictograms
Note
Equipment optimization tip
Prohibited action notice
Noteworthy point warning
Danger or potential risk warning
Reminder of the pre-requisites for implementation of the next instructions
™
Labguard is one of bioMérieux's registered trademarks.
The information and graphs contained in this manual are not binding. bioMérieux therefore reserves
the right to implement changes to the document without prior notice.
bioMérieux will not approve any modifications whatsoever to the equipment implemented by
the user. bioMérieux shall under no circumstance be held liable for any direct or
consequential injury or damage whatsoever suffered by the user or by any third party, as a
result of modifications to the equipment.
• This equipment is for professional use only.
• Users are required to read all the accompanying documents, including the statutory
information, before using the equipment.
Contents
Unpacking the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Learning about the equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
™
Labguard 3D equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Switching the equipment on / off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Turning the device on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Turning the device off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Understanding the indicator lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Alarm indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Status indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Changing the batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cleaning the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
14
14
14
Options and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Equipment conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FCC compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Industry conformity Canada (IC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EC compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compliance statement
16
16
16
17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1
Unpacking the device
Check that the device has not been damaged during transport. Then check that all the accessories
listed below are present.
Transmitter
• Unit
• Unit support
Labguard 3
MOBI_HR_QSG_EN-A
2
Learning about the equipment
Labguard 3D™ equipment
™
With Labguard 3D equipment, you can:
• Simultaneously measure the different physical parameters of the laboratory (temperature,
humidity, CO2).
• Provide alerts with visual alarms in real time in case of anomalies.
®
• Save and transfer data and alarms to the Labguard software.
Front
Multi-function button
Status indicator
Alarm indicator
Labguard 3
MOBI_HR_QSG_EN-A
Rear
4 battery access screws.
Labguard 3
MOBI_HR_QSG_EN-A
3
Installing the device
1. Fix the Tomguard support to the wall or to the unit to be monitored using the two screws or
adhesive strips at the rear of the support.
2. Slide the device into the support.
3. For greater security, you can add a padlock.
Labguard 3
MOBI_HR_QSG_EN-A
4
Switching the equipment on / off
Turning the device on
To turn the device on, press and hold the multi-function button for 5 seconds.
The status light turns green.
Turning the device off
To turn the device off, press and hold the multi-function button for 5 seconds.
The status light turns red.
Labguard 3
10
MOBI_HR_QSG_EN-A
5
Understanding the indicator lights
Alarm indicators
The transmitter signals technical problems or measurement problems via alarms.
The alarm indicators specify the type of alarm:
Indicator lights
Color
Red
Alarm origin
Sensor
Type of alarm
Time threshold exceeded.
Orange
Sensor
Threshold exceeded.
Purple
Sensor
Sensor absent.
Blue
Transmitter
Communication absent.
Yellow
Transmitter
Mains power supply absent.
Labguard 3
11
MOBI_HR_QSG_EN-A
Status indicator
Check the status of the battery and the power of the radio signal by pressing the multi-function
button for one second:
• The status indicator lights up and indicates the battery status.
• The status indicator lights up again and indicates the power of the radio signal status.
Indicator lights
Status
Good.
Average.
Poor.
Labguard 3
12
MOBI_HR_QSG_EN-A
6
Technical characteristics
Environmental
conditions
Altitude
Temperature
Relative humidity
(Rh)
Product power
supply
up to 2,000 m
from 0 to 40°C max.
from 10 to 80%
Battery:
Pollution level
Atmospheric pressure
Installation category
Device dimensions (W x H x D)
• 2 Li AAA batteries 1.5 V; 1,200 mAh, compliant with
CEI 60086-4 standard
700 hPa to 1,100 hPa
Type II according to Directive CEI 664
Device (mm):
Device in packaging (mm):
Device weight
• 61 x 94 x 23
Device (g):
• 167 x 133 x 74
Device in packaging (g):
Wireless
• 110
Emission bandwidth:
• 170
Range:
• 865 to 868 Mhz,
60 channels
• 868 to 868.8 Mhz,
12 channels
• 902 to 912 Mhz,
20 channels
• 433.05 to 434.79 Mhz,
8 channels
• 100 m inside
• 400 m outside
Labguard 3
13
MOBI_HR_QSG_EN-A
7
Maintenance
Changing the batteries
Risk of explosion :
• Do not place the battery the wrong way round.
• Do not short circuit.
• Do not use damaged or leaking batteries.
• Do not incinerate, recharge, dismantle, crush or expose to water.
1. Unscrew the lower part located at the rear of the device.
2. Remove the batteries carefully and replace them making sure the positive (+) and negative (-)
terminals are correctly positioned.
3. Re-position the lower part then screw it back on.
Only use recommended models to replace the battery.
Disposal
Recycle the lithium batteries in accordance with enforceable regulations.
Dispose of them by the appropriate means put in place.
Cleaning the device
Clean the equipment using a cloth dampened with ethanol or any other common disinfectant.
However, avoid using formol, solvents, heat greater than 80°C (flames, autoclaving) or cleaning by
dipping or spraying.
Labguard 3
14
MOBI_HR_QSG_EN-A
8
Options and accessories
Use the following options and accessories for optimum use of the device.
Reference
416053
416055
416054
416056
416068
416057
416070
Designation
Mains power supply µUSB_EU
Mains power supply µUSB_UK
Mains power supply µUSB_US
Mains power supply µUSB_AU/CN
Li batteries AAA 1.5V (2u)
Sensor extension cable 1 m
µUSB/USB cable 2 m
Labguard 3
15
MOBI_HR_QSG_EN-A
9
Equipment conformity
FCC compliance
This equipment has been declared in compliance with FCC regulations, section 15, applicable to class
B digital equipments. These regulations are designed to provide adequate protection against harmful
interferences in a residential installation. This equipment generates, uses and may emit radio-electric
waves. It can generate interferences that may be harmful to radio-communications if it is not
installed or used according to the instructions. Using this equipment in a specific installation may
generate harmful interferences, in which case the user may need to correct the interference using
one or all of the following methods:
• Redirect or move the receiver aerial
• Move the equipment away from the receiver
• Plug the equipment into a different socket from the one used for the receiver
• Contact the distributor or get help from a radio / TV technician.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
• this device may not cause harmful interference.
• this device must accept any interference received, including interference that may cause
undesired operation.
This equipment complies with FCC’s radiation exposure limis set forth for an uncontrolled
environment under the following conditions:
• This equipment should be installed and operated such that a minimum separation distance of
20cm is maintained between the equipment and user’s/neraby person’s body at all times.
• This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
NOTE: The grantee is not responsible for any changes or modifications not expressly approved by the
party responsible fr compliance. Such modifications could void the user's authority to operate the
equipment.
Industry conformity Canada (IC)
This class B digital equipment complies with Canadian standard NMB- 03.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions :
• this device may not cause interference.
• this device must accept any interference, including interference that may cause undesired
operation.
Labguard 3
16
MOBI_HR_QSG_EN-A
EC compliance
This class B numeric equipment complies with the relevant EC directives and standards listed in the
accompanying certificate(s). Class B equipment is equipment suitable for use in domestic
establishments and in establishments directly connected to a low voltage power supply network
which supplies buildings used for domestic purposes. Class B equipment shall meet class B limits.
Compliance statement
Via this statement, we
bioMérieux SA
69280 MARCY l’ÉTOILE- FRANCE
hereby declare that the product designated hereafter - as a result of its design and its type as well as
the model that we have put into circulation - meets the fundamental health and safety requirements
defined by the EC directive concerned.
This statement shall be rendered invalid by any modification not approved by us.
Machine designation:
Model and reference type:
Applicable EC directives:
The technical documents were
written by:
Date / Manufacturer's signature:
Monitoring hardware
Humidity
• EC low voltage Directive (2006/95/EC)
• EC-ECM directive (2004/108/EC)
•
EN 61010-1 (Ed. 2010): 2010, EN 61326-1 (Ed. 2006): 2006, EN
301 489-3 (Ed. 2002 V1.4.1): 2002 V1.4.1 EN 300-220-2 V2.4.1
EN 62479: 2010
Mr Develon
(Authorized person for documentation)
13 June 2013
Signatory's position:
Instrument R & D Manager
Harmonized standards applied in
particular:
Labguard 3
17
MOBI_HR_QSG_EN-A
Intentionally left blank.
Intentionally left blank.


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2013:12:24 10:57:24+01:00
Modify Date                     : 2013:12:24 10:57:24+01:00
Creator                         : AH XSL Formatter V6.0 MR8 for Windows : 6.0.9.10681 (2013/04/23 18:22JST)
Producer                        : Antenna House PDF Output Library 6.0.396 (Windows)
Title                           : Quick start guide
Subject                         : MOBI_HR_QSG_EN-A
Trapped                         : False
Page Count                      : 20
Page Mode                       : UseOutlines
Language                        : EN
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AA8Y-416030

Navigation menu