Biolight Meditech M70C Fingertip Pulse Oximeter User Manual

Guangdong Biolight Meditech Co.,Ltd Fingertip Pulse Oximeter Users Manual

Users Manual

Operator’s Manual Fingertip Pulse Oximeter Version number of this manual: V1.1     General Description                                                             The measurement of oxygen saturation of arterial blood (also known as pulse oxygen  saturation,  usually  shortened  as  SpO2)  adopts  the  principles  of  light spectra and volume tracing. The LED emits lights with two specific wavelengths, which are selectively absorbed by oxygenated hemoglobin and deoxyhemoglobin. The  optical receptor  measures  the  changes  in  the  light  intensity  after  the  light passes the capillary network and  estimates the ratio of  oxygenated hemoglobin and the total hemoglobin.   The mechanical activity of the heart cause arterial pulse, by measuring the pulse we can get PR value .     Precautions For Use                                                      Explosion hazard. Do not use the oximeter in the presence of flammable anesthetics mixture with air, oxygen, or hydrogen.  When the oximeter is in use, there should not be any great power appliances such  as  high  voltage  cables,  X-ray  machine,  ultrasound  equipment  and electrizer in use nearby.    Keep the oximeter away from dust, vibration, corrosive substances, explosive materials, high temperature and moisture.  This oximeter does not have alarm function; please do not use this product in the environment where alarm is required.  The oximeter should be handled with care so as to avoid shocks and falls.    When the oximeter is in use, it must be ensured that the batteries have sufficient capacity; otherwise there might be such phenomena as starting-up abnormalities or inaccurate measurement data, etc.      Please don’t use pointed objects such as pen point or nails to press operation, otherwise it might cause permanent damage to the surface of the keyboard.  Don’t make any clinical judgments based only on the oximeter. The oximeter is intended only as an adjunct in patient assessment. It must be used in conjunction with clinical signs and symptoms, as well as doctor’s diagnoses.  To ensure accurate performance and prevent device failure, do not expose the oximeter to extreme moisture, such as direct exposure to rain. Such exposure may cause inaccurate performance or device failure.  Do  not  conduct  SpO2  measurement  on  the  finger  smeared  with nail  polish, otherwise this will lead to unreliable measurement results.  The enclosure shall only be opened by the authorized person.  In order to have more accurate measurements of SpO2 and PR, the oximeter should be used in quiet and comfortable environment.  Follow  local  ordinances  and  recycling  instructions  regarding  disposal  or recycling of the device and device components, including batteries.  Prolonged  continuous  monitoring  may  increase  the  risk  of  unexpected changes  in  skin  characteristics,  such  as  irritation,  reddening,  blistering  or burns. Inspect the sensor site every two hours and move the sensor if the skin quality changes.    Pulse oximeter simulator can not be used to access the accuracy of the pulse oximeter.  This device complies with Part 15 of the FCC Rules. Operation is subject to the  following  two  conditions:  (1)  This  device  may  not  cause  harmful interference; (2) This device must accept any interference received, including interference that may cause undesired operation. The  user is  cautioned that  changes  or modifications not  expressly  approved by  the  party  responsible  for  compliance  could  void  the  user's  authority  to operate the equipment FCC STATEMENT: This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed  to  provide  reasonable  protection  against  harmful  interference  in  a residential installation. This equipment generates, uses and can radiate radio frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the instructions,  may  cause  harmful  interference  to  radio  communications. However, there is no guarantee that interference will not occur in a particular installation. If  this  equipment  does  cause  harmful  interference  to  radio  or  television reception, which can be determined by turning the equipment off and on, the user  is  encouraged  to  try  to  correct the  interference  by  one  or  more  of  the following measures:   -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver.   --  Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to which the receiver is connected.   -- Consult the dealer or an experienced radio/TV technician for help. FCC RADIATION EXPOSURE STATEMENT: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.   This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.     Intended Use                                  The  Fingertip  Pulse  Oximeter  is  intended  to  measure  functional  arterial oxygen  saturation  (SpO2)  and  pulse  rate  of  adult  and  pediatric  patients  in hospital, hospital type facilities, as well as in the home care environment. The oximeter is not suitable to monitor patient continuously for long term.     Battery Installations                                                       1. Press the button down on the back panel of oximeter and push     the battery cover horizontally along the arrow shown as below:   2. Install the batteries into battery cabin in correct polarities.   3. Close the battery cover. Notes:  Put or remove batteries in right order, or it may damage   the bracket.    Battery polarities must be correctly installed. Otherwise, damage might be caused to device.  Please remove the battery if the oximeter will not be used for long time.     Software Download And Installation                                     1. Software download methods:  Users  who  use  the  ISO  system  device  can  log  in  iphone  App  Store, enter ”wearcare” and search for the of “SpO2 monitoring software” in the searching results.      Users who use the Android system device can log in the wearcare official website: http://www.wearcare.cn for download. 2. Download  SpO2  monitoring  software,  click  installation  button  for  free installation.     Operation Instructions                                                     1. Install two AAA batteries into battery cassette before closing its cover. 2. Open the receiving device (such as mobile phone, tablet PC etc.), then turn on the Bluetooth. 3. Start the SpO2 monitoring software and connect automatically, the prompt message” Complete device connection”. Till now, users can perform SpO2 monitoring. 4. Nip the oximeter, then insert one finger into the rubber hole of the oximeter before releasing the oximeter, and your nail    must be upward.                       5. Press the function button once on front panel.           6. Your finger and body do not tremble during measuring.   7. Read corresponding data on the display screen. 8. After turning on the oximeter, each time you press the power switch, the display screen will change to another direction. There are two display modes. If you long press the power switch, you can adjust the brightness of screen from 1 to 5.      ① SpO2 Plethysmogram(normalized) ② SpO2 reading ③ Pulse rate reading ④ Indication of battery capacity ⑤ Indication of pulse intensity ⑥ Indication of screen brightness ⑦ Display modes     Maintenance                                   1. Use a soft cloth dampened with either a commercial, nonabrasive cleaner, or a solution of 70% alcohol in water, softly wipe the surfaces of the oximeter. 2.  The  most  commonly  used  hospital  cleaning  agent  and  non-corrosive detergents  can  be  used  for cleaning  the  oximeter,  but please be  careful that many  types  of  detergents  must  be  diluted  before  use;  Please  use  them according to the directions of the manufacturers of the detergents.   3. Avoid using alcohol-based, amido or acetone-based detergents . 4. The casing of the oximeter should be kept from the contamination of filth and dirt,  and  it  can  be  wiped  with  non-velvet  soft  cloth.  When  cleaning,  don’t spill the liquid onto the instrument. Ensure no liquid is  allowed to  enter the inside of the oximeter.     5. It’s forbidden to use such grinding materials as wire brush or metal polishing agent, for these materials may cause damage to the panels of the oximeter.   6. Please do not soak the oximeter in liquid. ⑦⑦⑦⑦ Press the button down %100lobindeoxyhemog bin oxyhemoglohemoglobin oxygenated%SpO 2×+=②②②② ⑤⑤⑤⑤ ①①①① ⑥⑥⑥⑥ ③③③③ ④④④④
7. Under normal circumstances, it is unnecessary for the oximeter to have special maintenance, and cautions must be exercised on the following points during the use of the oximeter:    Please use the oximeter in the environment according to the requirements of the performance criteria.  Avoid exposure or direct sunlight.  Avoid excessive radioactive infrared rays or ultraviolet rays.  Avoid contacts with organic solutions, dusts or corrosive gases.      Product Specifications                                                      Measurement specifications SpO2 Measuring Range  0~100% Resolution  1% Accuracy  At 70%~100%, ±2%;At 0~69%, unspecified   Data update period  <13 s PR Measuring Range  25bpm~250 bpm Resolution  1 bpm Accuracy  ±1% or ± 1 bpm, whichever is greater Data update period  < 13 s  Battery specifications Type  Voltage two AAA alkaline battery  1.5 Volts DC (per battery) The oximeter uses two 1.5 V AAA type batteries and a set of new batteries can be used for more than 18 hours, depending on concrete battery types.  Environmental specifications     Operation Temperature  +5℃~+40℃ Atmospheric Pressure  700hPa~1060hPa Relative Humidity  ≤85%       Transport and Storage Temperature  -20℃~+55℃ Atmospheric Pressure  500hPa~1060hPa Relative Humidity  ≤93%  Physical specifications Weight  about 21g/54g (exclude / include battery) Dimensions  57mm(length) × 33mm(width) ×30mm(height)  Sensors specifications   Wavelength Pulse oximetry sensors contain LEDs that emit red light at a wavelength of approximately 660 nm and infrared light at a wavelength of approximately 905 nm.The total optical output power of the sensor LEDs is less than 15 mW.   This information may be useful to clinicians, such as those performing photodynamic therapy. Note: Sensor LED light emissions fall within Class 1 level, according to IEC 60825-1:2001. No special safety precautions are required.      Symbols Definitions                                                         Symbol  Definition  Type BF equipment (Refer to IEC 60601-1:2012) %SpO2 Oxygen saturation of arterial blood   /Min Pulse rate  Non-Alarm indication (The device does not have alarm function) IPX1  Enclosure degree of ingress protection. SN    Serial number    Symbol for the marking of electrical and electronics devices according to Directive 2002/96/EC. The device, accessories and the packaging have to be disposed of waste correctly at the end of the usage. Please follow Local Ordinances or Regulations for disposal. Note: The Oximeter is applied to this regulation.  Refer to this user’s manual.      Possible Problems And Solutions                                 Problems  Possible causes  Solution There is no response to the function button  The button can not be pressed to its position Ensure that the button is fully depressed. Battery capacities are low The batteries may be lost, discharged, or oriented incorrectly. Replaced them with new ones. The Pulse search time is too long   Perfusion may be too low Check the patient. Change the measuring site. Try another oximeter. Patient movement Interference due to patient activity may be preventing the oximeter from tracking the pulse. Keep the patient still, if possible.   Electromagnetic interference may be preventing the oximeter from tracking the pulse.   Remove the source of interference. There may be interference due to ambient light, or the oximeter may be on an extremity with a blood pressure cuff, arterial catheter, or intravascular line. Reposition oximeter, as necessary. Display is dark-or-bright Battery capacities are low.    Replace the batteries.  Guidance  and  manufacture’s  declaration–electromagnetic  ermissions-for  all EQUIPMENT and SYSTEMS Guidance and manufacture’s declaration – electromagnetic emission The  Fingertip  Pulse  Oximeter  is  intended  for  use  in  the  electromagnetic environment specified below. The customer of the user of the Fingertip Pulse Oximeter should assure that it is used in such and environment. Emission test Compliance Electromagnetic environment – guidance RF emissions CISPR 11 Group 1  The Fingertip Pulse Oximeter uses RF energy only for its internal function. Thus, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.   RF emission CISPR 11 Class B  The Fingertip Pulse Oximeter is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.   Applicable Models                                                                     M70C   Packing List                                     NO.  Item  Quantity 1  Oximeter  1   2  AAA battery  2   3  Cord  1   4  User’s manual  1     GuangdongBiolightMeditech Co.,Ltd. No.2  Innovation  First  Road,  Technical  Innovation  Coast,  Hi-tech  Zone   Zhuhai PEOPLE’S REPUBLIC OF CHINA Eiffestrasse 80, 20537     Hamburg Germany Shanghai International   Trading Corp. GmbH (Hamburg) ALL RIGHTS RESERVED                                           PN: 22-025-0019

Navigation menu