Biolight Meditech WT3 Electronic Thermometer User Manual

Guangdong Biolight Meditech Co.,Ltd Electronic Thermometer

User Manual

           WT3 Electronic Thermometer   User’s Manual             Guangdong Biolight Meditech Co., Ltd.
1 Product Information  Product Model:      WT3  Product Name:      Electronic Thermometer  Manufacturer Name:    Guangdong Biolight Meditech Co.,Ltd.  After Service Contact Information: Address: No.2 Innovation First Road, Technical Innovation Coast, Hi-tech Zone, Zhuhai, P.R. China Fax: +86-756-3399919 Post code: 519085 Toll-free consultation hot line: +86-400-8818-233  Revision History This manual has a revision number. This revision number changes whenever the manual is updated due to software or technical specification change. Contents of this manual are subject to change without prior notice.  Document No.: J/ WT3CE -A-008  Revision number: V1.0  Release time: April, 2017 Copyright © 2017 Guangdong Biolight Meditech Co., Ltd. All rights reserved.  CE mark   EC Representative Name:   Shanghai International Holding Corp. GmbH Europe) EC Representative Address: Eiffestrasse 80, 20537 Hamburg Germany
2 Statement Manufacturer holds the copyright of this manual, and we are also entitled to deal with  this  manual  as  confidential  files.  This  manual  is  only  used  for  operation, maintenance and service of product, someone else can not publish the manual. This manual contains exclusive information protected by copyright laws and we reserve  its  copyright.  Without  written  approval  of  manufacturer  no  parts  of  this manual shall be photocopied, Xeroxed or translated into other languages. The  contents  contained  in  this  manual  are  subject  to  amendments  without notification.  Manufacturer's Responsibility Only under the following circumstances will manufacturer be responsible for the safety, reliability and performance of the instrument:  All the installation, expansion, readjustment, renovation or repairs are conducted by the personnel certified by manufacturer.  The storage condition, operation condition and electrical status of the instrument conform to the product specification.  The instrument is used in accordance with the user’s manual.  About this manual This manual contains the instructions necessary to operate the product safely and in  accordance  with  its  function  and  intended  use.  Observance  of  this  manual  is  a prerequisite for proper product performance and correct operation.    This manual is based on the maximum configuration and therefore some contents may not apply to your product. If you have any question, please contact us.    This manual is an integral part of the product. It should always be kept close to the equipment so that it can be obtained conveniently when needed. Illustrations  are  for  reference  only.  They may  be  not  in conformity with  your products.
3 Signs in this manual:   Warning: Indicates a potential hazard or unsafe practice that, if   not avoided, will result in death or serious injury. Caution: Indicates a potential hazard or unsafe practice that, if not   avoided, could result in minor personal injury or product/property   damage.       Note: Provides application tips or other useful information to ensure that you get the most from your product.      
I Contents 1. Intended Use ............................................................................................................................. 1 2. Application ................................................................................................................................ 1 3. Contraindication ........................................................................................................................ 1 4. Product Component ................................................................................................................... 1 5. Safety Information .................................................................................................................... 1 6. Appearance ............................................................................................................................... 4 7. Download and Install The Software .......................................................................................... 4 8. Operation Instructions ............................................................................................................... 5 9. Normal Body Temperature ........................................................................................................ 8 10. Maintenance and Cleaning .................................................................................................... 9 11. Accessory and Specifications .............................................................................................. 10 12. Troubleshooting .................................................................................................................. 11 13. Equipment Symbols ............................................................................................................ 12 Appendix A Guidance and Manufacturer’s Declaration of EMC ................................................... 13
1 1. Intended Use The device is intended to be used for measuring and monitoring human temperature continuously. It can store and manage the temperature data. It can be used to measure armpit temperature for the adult and pediatric people.    2. Application The  device  is  intended  for  measuring  human  temperature.  It  can  be  used  in hospital and at home.  3. Contraindication People  whose  armpit  skin  are  damaged  or  have  inflammation  of  the  skin  are forbidden. 4. Product Component The product is composed of main unit and  temperature patch,  mobile terminal and PC terminal software.  5. Safety Information  Warning:  Any form of modification to this device is forbidden;  Don’t used the device together with MRI or CT equipment;  Explosion danger: don’t use the device in flammable anesthetic gas;  Don’t  squeeze  the  device.  If  the  housing  is  broken,  please  stop  using  the device.    
2    Caution:  Please  check  device  regularly  to  make  sure  that  it  contacts  skin  tightly; otherwise the data may be inaccurate.  The device is for indoor use only;  Please pay attention to the operation temperature and humidity. Using the device  in  a  condition  that  does  not  satisfy  the  requirement  may  lead measurement error;  The effective wireless transmission distance is no less than10m. If more than this  distance,  the  product  might  not  work.  Please  use  this  product  within effective wireless transmission distance;    After  measuring  temperature,  please  take  the  temperature  patch  off  the main unit to avoid the main unit keep starting up all the time and reduce the electric quantity.  Muscle and fat affect wireless transmission, so the transmission range would be weaken when adult or obese child use the device.  Magnetic  and  electrical  fields  are  capable  of  interfering  with  the  proper performance  of  the  device.  For  this  reason  make  sure  that  all  external equipments operated in the vicinity of the device comply with the relevant EMC requirements. Mobile phone, X-ray equipment or MRI devices are a possible  source  of  interference  as  they  may  emit  higher  levels  of electromagnetic radiation.      Caution: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference; (2) This device must accept any interference received, including interference that may cause undesired operation. The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment  FCC STATEMENT:  This equipment has been tested and found to comply with the limits for a
3 Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the instructions,  may  cause  harmful  interference  to  radio  communications. However,  there  is  no  guarantee  that  interference  will  not  occur  in  a particular installation.  If  this  equipment  does  cause  harmful  interference  to  radio  or  television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:   -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver.   -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   -- Consult the dealer or an experienced radio/TV technician for help.  FCC RADIATION EXPOSURE STATEMENT:  This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.    This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.      Note:  The device is not sterile;  This  product  has  been  calibrated.  No  other  routine  maintenance  and calibration is needed;    If the system upgrade, please update the program;    Doctor should make diagnosis on clinical manifestation and symptoms, only with using the device as subsidiary;  It is impossible that the application is incompatible with other application on your receiver. Please contact us if you meet this kind of matters;  If you have questions concerning setting up, using, maintaining of the device or any unexpected events, please contact manufacturer or its representatives.  When  the  patient  is  the  operator,  please  use  and  maintain  the  device 
4 according to this manual.  The thermometer starts up and shuts down automatically. When you install the  main  unit  in  the  temperature  patch,  it  will  start  up  automatically. Likewise, when you take the main unit out from temperature patch, it will shut down automatically;  When  the  thermometer  doesn’t  connect  to  the  mobile  application,  the indicator light will flash twice periodically. And when the thermometer syncs with the mobile application, the indicator light will flash once periodically;  This product has overrun prompted function, and users can set the alarm limit themselves.   6. Appearance Front View:                                 Rear View:                     7. Download and Install The Software 1. Software download methods:  Users who use the iOS system device can enter App Store, search “Biolight” and you  can  find  an  app  called  “Temp  Sitter”  in  the  searching  results.  Or  scan  the  QR code of iOS on the packing box to download.  Users  who  use  the  Android  system  device  can  enter      Google  play,  search “Biolight” and  you can find an app called “Temp Sitter” in the searching results for download. Or scan the QR code of Android on the packing box to download. Sensor
5 2.  Download  the  software  of  “Temp  Sitter”          ,  click  installation  button  for  free installation. 3. You will need to register your email at initial mobile application installation. 4. For more information and FAQ go to the Settings section in the mobile app under the FAQ section. 8. Operation Instructions 1) Open the app and Bluetooth on your smartphone. 2) Take  out  the  thermometer  from  packing  box.  Install  main  unit  on  the     temperature patch, It will start up automatically. The indicator light flashes fast. 3) Enable the software. The device will connect automatically. When it connects successfully, it will display the message “Connects successfully”.   4) To wear the thermometer. Here are the steps to follows: Step 1:     When  the  thermometer  connects  to  mobile  application  successfully,  the  Bluetooth indicator light will flash.      Main unit Temperature patch
6 Step 2:     Step 3:   Remove the backing from the temperature patch and stick the thermometer onto right above underarm point.
7 Step 4:  Step 5:   Clamp armpit for 5~8 minutes. The measuring result will be transmitted to mobile terminal application software immediately via wireless signal transmission. Then take the  main  unit  off  the  temperature  patch  and  dispose  the  temperature  patch appropriately.  Adult should help child to wear and operate the device.  Please note it takes at least for 5~8 minutes to get exact temperature.  After you finish taking the temperature, place the thermometer back into its storage case to avoid consuming battery power.
8     Caution:  We  recommend  the  users  to  use  the  original  manufactured  temperature patch.  You’d  better  wear  the  device  in  a  cool  environment  to  get  better wearing experience. If you feel unwell (uncomfortable or allergic) when use the temperature patch, please replace other temperature patch as doctor’s advice;  When measuring for a long time, please check whether there is skin allergy phenomenon at site. If there is allergy, you should immediately stop using it;  Please  do  not  re-paste  the  temperature  patch  if  it  appears  fold,  a  new temperature patch is required;  Skin preparation in advance is required when worn by adult. Please make sure that skin is clean and dry;  Please clean the surface of the device with 75% concentrated medical alcohol before and after use it. You should clean the skin contacted the device with medicinal alcohol after taking off the device. The material that contacts skin is nontoxic, nonirritating and will not cause allergy or any other side effect.  To avoid the disruption from an incoming call or text message during  the measurement, we recommend to switch your IOS device (if with 3G card) to flight mode and turn on Bluetooth.  That pet or pest touches the device may cause the user’s allergy or any other side  effect.  Please  clean  the  surface  of  the  device  with  75%  concentrated medical alcohol before use it.  That children play the device may damage the temperature measuring probe and affect the measure accuracy.  9. Normal Body Temperature Age/year Normal body temperature scope Celsius temperature/℃ Fahrenheit temperature/℉ 2 34.7~37.2 94.5~99.1 3~10 35.9~36.7 96.6~98.0 11~65 35.2~36.9 95.3~98.4 >65 35.6~36.3 96.0~97.4
9 The normal temperature can vary by: a) Age; b) Person; c) Time of day(often highest in the evening); Where on body the temperature was taken, body temperature can be raised by: a) Being active; b) Eating; c) Feeling strong emotions; d) Menstruating (women); e) Taking certain medicines; f) Being in a high temperature or high humidity; g) Teething (in a young child – but no higher than 37.8℃); h) Wearing heavy clothing.    Note:Different measure size  and different measure methods  may  lead  to different temperature value.    10. Maintenance and Cleaning 1. Clean the surface of the device with 75% concentrated medical alcohol before and after use it; 2. Please stop using the device when the low battery indication appears, otherwise it will not work correctly; 3. Working 8 hours per day, the product can be used at least 6 months. The treatment of the device and battery at the end of their life should be compliance with local laws and regulations; 4. The temperature patch is single use, do not reuse it.  Warning:  Do not sterilize or autoclave the device;  If you notice any deterioration or damage to temperature patch, stop from using the temperature patch immediately;  Other use of cleaning agents and disinfectants beside alcohol may damage the device and shorten product lifetime or cause safety hazards.   
10 11. Accessory and Specifications 11.1 Accessory    11.2 Safety Specification According to the MDD 93/42/EEC, the electronic thermometer is Type Ⅱa equipment. Classified according to the IEC60601-1 is as follows: Parts Classification of protection against electric shock Degree of protection against electric shock Degree of protection against ingress of liquid Degree of protection against hazards of explosion Mode of operation Mainframe Internally   CF IP22 Not suitable Continuous  Note: Internally:Internally powered equipment CF:Type CF applied part Not  suitable:Equipment  is  not  suitable  for  use  in  the  presence  of  flammable anesthetic mixture with air or with oxygen or nitrous oxide. IP22:The device can prevent the solid foreign matter whose diameter is not less than 12.5mm  into  the  equipment  shell,  and  prevent  the  effects  on  the equipment after dropping of water in the tilt angle of 15°. 10.3 Technical Specifications Production model WT3 Size   Main unit : 52.4mm×20.8mm×5.6mm Temperature patch:   91.3mm×23.5mm×7.2mm Weight   6.4g Number Items Quantity  1 Main unit One 2 Temperature patch Four 3 User manual One
11 Measure specifications   Measure scope 25.00℃~45.00℃ Measure accuracy ±0.05℃ (35.00℃~38.50℃) ±0.1℃ (25.00℃~34.99℃ and 38.51℃~45.00℃) Temperature unit  “℃”or“℉” Update time 3s~30s Bluetooth indicator light Not connected: flash twice continuously. Connected: flash once. App software platform IOS system iPhone4s,iPhone5,iPhone5s,iPhone6(s)/6P(s),iPad3+,iPad mini Android (4.3+) system Mobile phone, Palmtop Battery   Type   CR1620, 3V/80mAH button battery Work time ≥6 months (8 hours per day) Environment specifications Temperature   Operating: 5℃~+40℃; Transportation and storage: -20℃~+55℃. Humidity   Operating: 25%~95%(non condensing); Transportation  and  storage:  25% ~95%  (non condensing). Atmospheric pressure   Operating: 700hPa~1060hPa; Transportation and storage: 500hPa~1060hPa.  12. Troubleshooting Symptom   Possible Reason Solution   No warning voice System voice is closed Set the system voice properly Cannot turn on device 1. Main unit does not install in the temperature patch properly. 2. The battery power might be at shortage or no electricity; 3. The device itself might be 1. Install main unit in the temperature patch again to make sure electric contactor connected well. 2. Restart the device;
12 Symptom   Possible Reason Solution   damaged. 3. Contact customer service. Temperature data cannot be displayed properly 1. The device itself might be damaged. 2. Device does not place in right position. 3. Do not clamp armpit when using the device. 1. Contact customer service. 2. Stick the thermometer onto armpit area again. 3. Clamp armpit for 5~8 minutes. Cannot make connection between device and receiver 1. Bluetooth does not be open on receiver; 2. The version of Android in the receiver device isn’t 4.3 or 4.3+. 3. The version of Bluetooth is not 4.0; 4. Out of connection range. 1. Open Bluetooth; 2. Upgrade the Android system to version 4.3 or 4.3+. 3. Use the receiver device with Bluetooth 4.0; 4. Close to receiver or adjust the position of receiver.    Note:Electrical schematic diagram and component list are only provided to repair  station  or  personnel  which  have  been  confirmed  qualified  by  the manufacturer.  13. Equipment Symbols Symbol Symbol Note  Refer to this user’s manual. SN Serial number IP22 Enclosure degree of ingress protection.   
13 Appendix A Guidance and Manufacturer’s Declaration of EMC    Note:  This product needs special precautions regarding EMC and needs to be installed and put  into  service  according  to  the  EMC  information  provided,  and  this  unit  can  be affected by portable and mobile RF communications equipment.  Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit.     Caution:    This unit has been thoroughly tested and inspected to assure proper performance and operation.  This machine should not be used adjacent to or stacked with other equipment and that if  adjacent  or  stacked  use  is  necessary,  this  machine  should  be  observed  to  verify normal operation in the configuration in which it will be used.  Guidance and manufacture’s declaration – electromagnetic emission The device is intended for use in the electromagnetic environment specified below. The customer of the user of the device should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment – guidance RF emissions CISPR 11 Group 1 The  device use  RF  energy  only  for  its  internal function.  Therefore,  its  RF  emissions  are  very low and are not likely to cause any interference in nearby electronic equipment. RF emission CISPR 11 Class B The  device  is  suitable  for  use  in  all establishments,  including  domestic establishments  and  those  directly  connected  to the public low-voltage power supply network that supplies buildings used for domestic purposes. Harmonic emissions IEC 61000-3-2 Not applicable (Battery operated device) Voltage fluctuations/ flicker emissions IEC 61000-3-3 Not applicable (Battery operated device)  
14  Guidance and manufacture’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of device should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance Electrostatic discharge (ESD) IEC 61000-4-2 ±6 kV contact ±8 kV air ±6 kV contact ±8 kV air Floors should be wood, concrete or ceramic  tile.  If  floor  are  covered with synthetic material, the relative humidity should be at least 30%. Electrical fast transient/burst IEC 61000-4-4 ±2 kV for power supply lines ±1 kV for input/output   lines Not applicable (Battery operated device) Mains power quality should be that of a typical commercial or hospital environment. Surge IEC 61000-4-5 ± 1 kV line(s) to line(s) ± 2 kV line(s) to earth Not applicable (Battery operated device) Mains power quality should be that of a typical commercial or hospital environment. Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 <5% UT   (>95% dip in UT) for 0.5 cycle  40% UT (60% dip in UT) for 5 cycles  70% UT (30% dip in UT) for 25 cycles  <5% UT   (>95% dip in UT) for 5 sec Not applicable (Battery operated device) Mains power quality should be that of a typical commercial or hospital environment.  If  the  user  of  the device requires continued operation during  power  mains  interruptions, it  is  recommended  that  the  device be powered from an uninterruptible power supply or a battery.  Power  frequency (50Hz/60Hz) magnetic  field  IEC 61000-4-8 3 A/m 3 A/m Power  frequency  magnetic  fields should be at levels characteristic of a  typical  location  in  a  typical commercial  or  hospital environment. NOTE    UT is the a.c. mains voltage prior to application of the test level.
15 Guidance and manufacture’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment - guidance      Conducted RF IEC 61000-4-6       3 Vrms 150 kHz to 80 MHz Not applicable (Battery operated device)  Portable  and  mobile  RF  communications  equipment  should  be used no closer to any part of the device, including cables, than the recommended  separation  distance  calculated  from  the  equation applicable to the frequency of the transmitter. Recommended separation distance                Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey,a should be less than the compliance level in each frequency range.b Interference may occur in the vicinity of equipment marked with the following symbol:         Radiated RF IEC 61000-4-3    3 V/m 80 MHz to 2.5 GHz    3 V/m
16 NOTE 1        At 80 MHz and 800 MHz, the higher frequency range applies. NOTE  2        These  guidelines  may  not  apply  in  all  situations.  Electromagnetic  propagation  is  affected  by absorption and reflection from structures, objects and people.  a            Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land  mobile  radios,  amateur  radio,  AM  and  FM  radio  broadcast  and  TV  broadcast  cannot  be  predicted theoretically  with  accuracy.  To  assess  the  electromagnetic  environment  due  to  fixed  RF  transmitters,  an electromagnetic site survey should be considered. If the measured field strength in the location in which the device is  used  exceeds  the  applicable  RF  compliance  level  above,  the  device  should  be  observed  to  verify  normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the device. b          Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
17  Recommended separation distances between   portable and mobile RF communications equipment and the device . The  device  is  intended  for  use  in  an  electromagnetic  environment  in  which  radiated  RF  disturbances  are controlled. The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the device as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter (W) Separation distance according to frequency of transmitter (m) 150 KHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz 0.01 0.12 0.12 0.23 0.1 0.38 0.38 0.73 1 1.2 1.2 2.3 10 3.8 3.8 7.3 100 12 12 23 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.  NOTE 1      At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE  2      These  guidelines  may  not  apply  in  all  situations.  Electromagnetic  propagation  is  affected  by absorption and reflection from structures, objects and people.