Data Sheet Battery Capacity Analyzer with record storage Model 603B Features & benefits The 603B handheld battery capacity analyzer tests 6 and 12 volt sealed lead acid batteries with capacities up to 100 ampere hour (Ah). Test results include voltage, state of charge, and internal resistance. This analyzer also features a built-in USB port and internal memory to store battery information, test configuration, and measurement results for up to 50 batteries. n Test 6 and 12 volt batteries up to 100 Ah n Test both open and loaded battery voltage n Powered by the battery under test (no need to replace battery) n Fast test cycle time for quick sorting of batteries n Measurements are stored to internal memory n Pre-load up to 50 test configurations from the computer via USB Application Ideal choice for testing sealed lead acid batteries commonly used in intrusion detection, fire alarm, security camera, access control, industrial control and other battery backup systems. n Test configurations include site, panel, battery information and more n Add or edit records using the key pad or remote computer n Real-time clock for date and time stamp of measurement records n Export Fast results Getting battery measurement results fast is critical in the field. Immediately upon connection, the 603B measures and displays open battery voltage. Battery voltage under load, state of charge and internal resistance are determined within seconds, by simply entering the battery ampere hour (Ah) rating. Additionally, the 603B features a charger circuit test for a complete evaluation of the battery system. further analysis n User configurable Pass/Fail criteria n Built-in charger circuit test n Twist-lock test leads can be changed in seconds n Field programmable DC load for testing system output circuits n 3 user configurable SOC tables for each voltage n Closed case calibration and firmware updates via USB Measurement recording Battery maintenance programs typically include periodic testing and record keeping. The 603B stores battery measurement data to internal memory for up to 50 batteries tracked by serial number. Information like test date, test time, building name, panel location and system type are also recorded. The 603B includes computer software to pre-configure the analyzer before field testing. Once the analyzer is configured, simply select the building record, verify the battery serial number and start the test. This saves time while minimizing data entry errors and simplifies compiling inspection data for an unlimited number of battery records. Technical data subject to change © B&K Precision Corp. 2018 record data to a CSV file for www.bkprecision.com Battery Capacity Analyzer with record storage Model 603B Front panel Bright display Test leads Two types of test leads are included, one set with terminal type connectors, and the other set with tab type connectors. USB type B interface Rubber keypad Terminal type connectors Reverse polarity LED Tab type connectors Terminal type test leads Tab type test leads Removable test leads Twist-lock connectors make it easy to change test leads. Two sets of test leads are included. One set is for connecting to smaller tab terminals and one for larger screw terminal batteries. Charger adapters 2 www.bkprecision.com Battery Capacity Analyzer with record storage Model 603B Operation highlights Quick test mode Built-in database VO = 12.78 Volts ENTER AH, Nominal IR AH = 007, NIR = N/A Press TEST to start Simply enter the battery’s Ah value and press the Test button. BATTERY QUICK TEST VO : 12. 77 SOC : 90 VL : 12. 28 IR : 24m RS : N/A Results display in seconds and include the following: VO Voltage open VL Voltage loaded IR Internal resistance SOC State of charge percent remaining Rec ord R 50 RRe ec ReRceceococrodrodrd4 49 R e R r o 4 d c e ReRcecocorodrdrd4 4949 9 9 R Receco ordrd 4 49 9 RR e r 9 o 4 d c e R r R e c or d 4 9 RRe ecocorodrd d4 4949 9 ReRc eceocrodcrodrd4rd494949 9 ord 03 9 02 Batt ery Det ail & Loc atio Con 0 n fi e 5 g r f u y Batt r o & a M t t i L on eSaes ery oca urem & LTo tion Det ecsat ti ent a o C Dat il onnD Tes a figeuta t Co railtio Mnefiag n u surraeti Mea one m sure nt D men ata t Da ta Rec ord 01 Tes t Batt Record set The 603B stores battery and location details, test configuration, and measurement data within the 50 battery records available in the unit. These records are easily transferred to a computer, which allows for storage of an unlimited number of record sets. The last settings used are stored in memory to support quick testing of batteries of the same type. Configuration screen BATTERY QUICK TEST VO : 12. 66 SOC : 90 VL : 12. 22 IR : 25m RS : PASS By providing the nominal internal resistance (NIR), the pass/fail indicator makes it easy to identify a battery that has reached the end of its useful life. Results screen Application software Used to upload and download record sets. Edit and save records in row and column format. Resulting measurement data can be viewed or exported in spreadsheet format for detailed analysis. Internal resistance Data Saved VO: 12.82 SOC: 90 VL: 12.31 TMP: 25 IR: 24m The internal resistance (IR) is a useful indicator of the battery’s health. As the battery reaches its end of life, the IR will ramp up quickly, which reduces the battery capacity and the amount of current available. In Record mode the IR measurement is recorded in the 603B memory and can be uploaded to a computer for later analyses. 3 www.bkprecision.com Battery Capacity Analyzer with record storage Model 603B Operation highlights Temperature record Adjust VO: 12.82 VL: 12.31 IR: 24m Charge circuit testing TMP: SOC: 90 TMP: 23 RS: PASS Keeping records of the battery’s operating environment such as temperature is helpful for understanding the battery’s life. The 603B records the predefined temperature and prompts the user for adjustment after the test is completed. CHARGER TEST OCV : 13.74 LCV : 13.42 REC:001 Press TEST or CANCEL Both the open voltage (VO) and the voltage under load (VL) are displayed to provide additional information about the charger regulator circuit. Using Record mode enables storage of results to internal memory. An adapter is included to make it easy to connect to standard tab-type charger circuits. State of Charge (SOC) profiles Setting 12V SOC #1 Setting 12V SOC #2 Setting 12V SOC #3 Setting 6V SOC #4 SOC Prof ile - SOC1 100 = 12.800V 90 = 12.650V 80 = 12.500V SOC profile tables are used to evaluate the battery’s state of charge. One default and 3 user-configurable tables are available for characterizing 6 V and 12 V batteries. The user defined tables allow advanced users to tune the 603B to meet their specific needs. State of Charge (SOC) weighting SOC Weighting On Firmware Version Fan Start Load test mode LC : 12.25A LT: 2.0sec VO : 12.13V VC: 11 . 95V Arrow Keys to Set TEST Key to Test At the core of the 603B is a programmable DC electronic load. This load can be programmed in the field to test control panel outputs or end of line output circuits. Load current can be set from 0.5 to 10 Amps and the time can be set from 0.5 to 5.0 seconds. Open and loaded voltage is displayed after the test is completed. Closed case calibration and firmware updates Voltage Calibration Current Calibration Load Calibration The 603B can be calibrated by the user through the USB port using a computer and reference power supply. Firmware updates are also installed via the USB port. When the battery’s internal resistance (IR) is above the user-set nominal value, the open voltage measurement no longer results in an accurate SOC value. The 603B uses weighted values to more accurately represent the SOC. This feature can be enabled by the user and its state is recorded in Record mode. 4 www.bkprecision.com Battery Capacity Analyzer with record storage Model 603B Specifications Range 603B Open voltage Displayed Quick Test Mode Record Mode VO Voltage open VL Voltage loaded IR Internal resistance SOC State of charge percentage RS Resistance status, pass/fail user configured VO Voltage open VL Voltage loaded IR Internal resistance SOC State of charge percentage SOT SOC table used for test Tmp User provided temperature RS Resistance status, pass/fail user configured Data 5.5 V to 8.5 V Battery test 8 V to 14 V Charge circuit test 8 V to 17 V Battery test N/A Charge circuit test 16 V to 28 V Current 1 A to 10 A Resistance (IR) 1 mΩ to 100 mΩ Setting Voltage (record mode) 6 V, 12 V Ah (record mode) 1 Ah – 100 Ah in 1 A steps Current (load test mode) 0.5 A to 10 A in 0.5 A steps 0.5 sec to 5 sec in 0.5 sec steps Record number N/A, 0.1 mΩ to 199 mΩ Dat Date Temperature (record mode) User settable Tme Time Real Time Clock √ Bld Building Data Time Log √ Loc Location Cycle Time ≤ 5 seconds, typical Typ Type of system Battery Load current 0.1 C based on Ah value entered by user Ser Battery serial number Mfd Battery manufacturer or in-service date Tmp User provided temperature V Battery voltage (as labeled) Ah Battery ampere hour (as labeled) VO Voltage open VL Voltage loaded RC Remaining capacity (SOC) NIR Nominal internal resistance used for test IR Measured internal resistance OCV Open charger voltage LCV Loaded charge voltage WEI Weighting state during test, Y or N SOT SOC table used for test SOV SOC voltage used for test Voltage 0.2% ±10 mV Current 0.2% ±10 mA Resistance (IR) 5% ±1 mΩ v080218 24 Volts Charge circuit test Time (load test mode) Accuracy 5 12 Volts 5.5 V to 6.8 V Nominal Internal Resistance (NIR) Recorded Rec 6 Volts 5.5 V to 30 V Battery test 2 default tables, one for 6 and one for 12 V SOC tables 3 user configurable tables for 6 V 3 user configurable tables for 12 V Battery Charger Circuit Test 6, 12 or 24 Volt Charger Circuits Quick Test mode Measurement data is displayed but not recorded Record mode Records open and loaded charger circuit voltage Pass / Fail Optional, calculated based on user provided NIR Internal Memory 50 records General Minimum Operating Voltage 5.5 V Minimum Operating Current 0.45 A with back light on, typical Display 20 x 4 LCD with back light Remote Communication USB Cable (type B) Test Leads Type Detachable Storage Temperature -10º C to 70º C Dimensions (W x H x D) 2.91” x 10.44” x 2.28” (74 x 265.1 x 58 mm) Weight 2.65 lbs (1.2 kg) Warranty One year Included Accessories USB (type B) cable, two sets alligator test leads, adapter for testing charger circuit, test report, certificate, user manual available for download. www.bkprecision.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c143 79.161424, 2017/09/22-11:52:47 Create Date : 2018:08:02 08:45:54-07:00 Metadata Date : 2018:08:02 08:45:57-07:00 Modify Date : 2018:08:02 08:45:57-07:00 Creator Tool : Adobe InDesign CC 13.1 (Macintosh) Instance ID : uuid:4f7079e7-31dc-2f42-9f3f-dfa3ecc6955b Original Document ID : xmp.did:b0419f29-6e4c-4e99-a938-3538e6f9fb8c Document ID : xmp.id:be5f6a5d-85cd-4687-87c0-5aff74c37f68 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:c0cd12a1-528a-4e84-875b-9418a12e0b21 Derived From Document ID : xmp.did:11d0781d-0757-4c97-8a1b-8f226c105951 Derived From Original Document ID: xmp.did:b0419f29-6e4c-4e99-a938-3538e6f9fb8c Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 13.1 (Macintosh) History Changed : / History When : 2018:08:02 08:45:54-07:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 5 Creator : Adobe InDesign CC 13.1 (Macintosh)EXIF Metadata provided by EXIF.tools