Data Sheet
Battery Capacity Analyzer
with record storage
Model 603B
Features & benefits
The 603B handheld battery capacity analyzer
tests 6 and 12 volt sealed lead acid batteries with
capacities up to 100 ampere hour (Ah). Test
results include voltage, state of charge, and
internal resistance. This analyzer also features a
built-in USB port and internal memory to store
battery information, test configuration, and
measurement results for up to 50 batteries.
n
Test 6 and 12 volt batteries up to 100 Ah
n
Test both open and loaded battery voltage
n
Powered by the battery under test (no need to
replace battery)
n
Fast test cycle time for quick sorting of
batteries
n
Measurements are stored to internal memory
n
Pre-load up to 50 test configurations from the
computer via USB
Application
Ideal choice for testing sealed lead acid
batteries commonly used in intrusion
detection, fire alarm, security camera, access
control, industrial control and other battery
backup systems.
n
Test configurations include site, panel, battery
information and more
n
Add or edit records using the key pad or
remote computer
n
Real-time clock for date and time stamp of
measurement records
n Export
Fast results
Getting battery measurement results fast is critical
in the field. Immediately upon connection, the
603B measures and displays open battery voltage.
Battery voltage under load, state of charge and
internal resistance are determined within seconds,
by simply entering the battery ampere hour (Ah)
rating. Additionally, the 603B features a charger
circuit test for a complete evaluation of the
battery system.
further analysis
n User
configurable Pass/Fail criteria
n Built-in
charger circuit test
n
Twist-lock test leads can be changed in seconds
n
Field programmable DC load for testing system
output circuits
n
3 user configurable SOC tables for each voltage
n
Closed case calibration and firmware updates
via USB
Measurement recording
Battery maintenance programs typically include
periodic testing and record keeping. The 603B
stores battery measurement data to internal
memory for up to 50 batteries tracked by serial
number. Information like test date, test time,
building name, panel location and system type
are also recorded. The 603B includes computer
software to pre-configure the analyzer before field
testing. Once the analyzer is configured, simply
select the building record, verify the battery serial
number and start the test. This saves time while
minimizing data entry errors and simplifies
compiling inspection data for an unlimited
number of battery records.
Technical data subject to change
© B&K Precision Corp. 2018
record data to a CSV file for
www.bkprecision.com
Battery Capacity Analyzer with record storage
Model 603B
Front panel
Bright display
Test leads
Two types of test leads are included, one
set with terminal type connectors, and the
other set with tab type connectors.
USB type B interface
Rubber keypad
Terminal type connectors
Reverse polarity LED
Tab type connectors
Terminal type test leads
Tab type test leads
Removable test leads
Twist-lock connectors make it easy to change test leads. Two sets of test leads are included. One
set is for connecting to smaller tab terminals and one for larger screw terminal batteries.
Charger adapters
2
www.bkprecision.com
Battery Capacity Analyzer with record storage
Model 603B
Operation highlights
Quick test mode
Built-in database
VO = 12.78 Volts
ENTER AH, Nominal IR
AH = 007, NIR = N/A
Press TEST to start
Simply enter the battery’s Ah value and press the Test button.
BATTERY QUICK TEST
VO : 12. 77 SOC : 90
VL : 12. 28
IR :
24m RS : N/A
Results display in seconds and include the following:
VO
Voltage open
VL
Voltage loaded
IR
Internal resistance
SOC
State of charge percent remaining
Rec
ord
R
50
RRe ec
ReRceceococrodrodrd4 49
R
e
R
r
o
4
d
c
e
ReRcecocorodrdrd4 4949 9 9
R
Receco ordrd 4 49 9
RR
e
r
9
o
4
d
c
e
R
r
R e c or d 4 9
RRe ecocorodrd d4 4949 9
ReRc eceocrodcrodrd4rd494949 9
ord 03 9
02
Batt
ery
Det
ail &
Loc
atio
Con 0
n
fi
e
5
g
r
f
u
y
Batt
r
o
&
a
M
t
t
i
L
on
eSaes
ery
oca
urem
& LTo
tion
Det
ecsat ti
ent
a
o
C
Dat
il
onnD
Tes
a
figeuta
t Co
railtio
Mnefiag
n
u
surraeti
Mea
one
m
sure
nt D
men
ata
t Da
ta
Rec
ord
01
Tes
t
Batt
Record set
The 603B stores battery and location details, test configuration, and
measurement data within the 50 battery records available in the unit. These
records are easily transferred to a computer, which allows for storage of an
unlimited number of record sets.
The last settings used are stored in memory to support quick testing of
batteries of the same type.
Configuration screen
BATTERY QUICK TEST
VO : 12. 66 SOC : 90
VL : 12. 22
IR :
25m RS : PASS
By providing the nominal internal resistance (NIR), the pass/fail indicator
makes it easy to identify a battery that has reached the end of its useful life.
Results screen
Application software
Used to upload and download record sets. Edit and save records in row and
column format. Resulting measurement data can be viewed or exported in
spreadsheet format for detailed analysis.
Internal resistance
Data Saved
VO: 12.82 SOC: 90
VL: 12.31 TMP: 25
IR: 24m
The internal resistance (IR) is a useful indicator of the battery’s health. As
the battery reaches its end of life, the IR will ramp up quickly, which reduces
the battery capacity and the amount of current available. In Record mode the
IR measurement is recorded in the 603B memory and can be uploaded to a
computer for later analyses.
3
www.bkprecision.com
Battery Capacity Analyzer with record storage
Model 603B
Operation highlights
Temperature record
Adjust
VO: 12.82
VL: 12.31
IR:
24m
Charge circuit testing
TMP:
SOC: 90
TMP: 23
RS: PASS
Keeping records of the battery’s operating environment such as temperature is
helpful for understanding the battery’s life. The 603B records the predefined
temperature and prompts the user for adjustment after the test is completed.
CHARGER TEST
OCV : 13.74
LCV : 13.42 REC:001
Press TEST or CANCEL
Both the open voltage (VO) and the voltage under load (VL) are displayed
to provide additional information about the charger regulator circuit. Using
Record mode enables storage of results to internal memory. An adapter is
included to make it easy to connect to standard tab-type charger circuits.
State of Charge (SOC) profiles
Setting 12V SOC #1
Setting 12V SOC #2
Setting 12V SOC #3
Setting 6V SOC #4
SOC Prof ile - SOC1
100 = 12.800V
90 = 12.650V
80 = 12.500V
SOC profile tables are used to evaluate the battery’s state of charge. One
default and 3 user-configurable tables are available for characterizing 6 V and
12 V batteries. The user defined tables allow advanced users to tune the 603B
to meet their specific needs.
State of Charge (SOC) weighting
SOC Weighting On
Firmware Version
Fan Start
Load test mode
LC : 12.25A LT: 2.0sec
VO : 12.13V VC: 11 . 95V
Arrow Keys to Set
TEST Key to Test
At the core of the 603B is a programmable DC electronic load. This load can
be programmed in the field to test control panel outputs or end of line output
circuits. Load current can be set from 0.5 to 10 Amps and the time can be set
from 0.5 to 5.0 seconds. Open and loaded voltage is displayed after the test is
completed.
Closed case calibration and firmware updates
Voltage Calibration
Current Calibration
Load Calibration
The 603B can be calibrated by the user through the USB port using a
computer and reference power supply. Firmware updates are also installed via
the USB port.
When the battery’s internal resistance (IR) is above the user-set nominal value,
the open voltage measurement no longer results in an accurate SOC value. The
603B uses weighted values to more accurately represent the SOC. This feature
can be enabled by the user and its state is recorded in Record mode.
4
www.bkprecision.com
Battery Capacity Analyzer with record storage
Model 603B
Specifications
Range
603B
Open voltage
Displayed
Quick Test Mode
Record Mode
VO
Voltage open
VL
Voltage loaded
IR
Internal resistance
SOC
State of charge percentage
RS
Resistance status, pass/fail user configured
VO
Voltage open
VL
Voltage loaded
IR
Internal resistance
SOC
State of charge percentage
SOT
SOC table used for test
Tmp
User provided temperature
RS
Resistance status, pass/fail user configured
Data
5.5 V to 8.5 V
Battery test
8 V to 14 V
Charge circuit test
8 V to 17 V
Battery test
N/A
Charge circuit test
16 V to 28 V
Current
1 A to 10 A
Resistance (IR)
1 mΩ to 100 mΩ
Setting
Voltage (record mode)
6 V, 12 V
Ah (record mode)
1 Ah – 100 Ah in 1 A steps
Current (load test mode)
0.5 A to 10 A in 0.5 A steps
0.5 sec to 5 sec in 0.5 sec steps
Record number
N/A, 0.1 mΩ to 199 mΩ
Dat
Date
Temperature (record mode)
User settable
Tme
Time
Real Time Clock
√
Bld
Building
Data Time Log
√
Loc
Location
Cycle Time
≤ 5 seconds, typical
Typ
Type of system
Battery Load current
0.1 C based on Ah value entered by user
Ser
Battery serial number
Mfd
Battery manufacturer or in-service date
Tmp
User provided temperature
V
Battery voltage (as labeled)
Ah
Battery ampere hour (as labeled)
VO
Voltage open
VL
Voltage loaded
RC
Remaining capacity (SOC)
NIR
Nominal internal resistance used for test
IR
Measured internal resistance
OCV
Open charger voltage
LCV
Loaded charge voltage
WEI
Weighting state during test, Y or N
SOT
SOC table used for test
SOV
SOC voltage used for test
Voltage
0.2% ±10 mV
Current
0.2% ±10 mA
Resistance (IR)
5% ±1 mΩ
v080218
24 Volts
Charge circuit test
Time (load test mode)
Accuracy
5
12 Volts
5.5 V to 6.8 V
Nominal Internal Resistance
(NIR)
Recorded
Rec
6 Volts
5.5 V to 30 V
Battery test
2 default tables, one for 6 and one for 12 V
SOC tables
3 user configurable tables for 6 V
3 user configurable tables for 12 V
Battery Charger Circuit Test
6, 12 or 24 Volt Charger
Circuits
Quick Test mode
Measurement data is
displayed but not recorded
Record mode
Records open and loaded
charger circuit voltage
Pass / Fail
Optional, calculated based on user provided NIR
Internal Memory
50 records
General
Minimum Operating Voltage
5.5 V
Minimum Operating Current
0.45 A with back light on, typical
Display
20 x 4 LCD with back light
Remote Communication
USB Cable (type B)
Test Leads Type
Detachable
Storage Temperature
-10º C to 70º C
Dimensions (W x H x D)
2.91” x 10.44” x 2.28” (74 x 265.1 x 58 mm)
Weight
2.65 lbs (1.2 kg)
Warranty
One year
Included Accessories
USB (type B) cable, two sets alligator test leads,
adapter for testing charger circuit, test report,
certificate, user manual available for download.
www.bkprecision.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c143 79.161424, 2017/09/22-11:52:47 Create Date : 2018:08:02 08:45:54-07:00 Metadata Date : 2018:08:02 08:45:57-07:00 Modify Date : 2018:08:02 08:45:57-07:00 Creator Tool : Adobe InDesign CC 13.1 (Macintosh) Instance ID : uuid:4f7079e7-31dc-2f42-9f3f-dfa3ecc6955b Original Document ID : xmp.did:b0419f29-6e4c-4e99-a938-3538e6f9fb8c Document ID : xmp.id:be5f6a5d-85cd-4687-87c0-5aff74c37f68 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:c0cd12a1-528a-4e84-875b-9418a12e0b21 Derived From Document ID : xmp.did:11d0781d-0757-4c97-8a1b-8f226c105951 Derived From Original Document ID: xmp.did:b0419f29-6e4c-4e99-a938-3538e6f9fb8c Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 13.1 (Macintosh) History Changed : / History When : 2018:08:02 08:45:54-07:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 5 Creator : Adobe InDesign CC 13.1 (Macintosh)EXIF Metadata provided by EXIF.tools