Black Diamond Equipment DSP01 Avalanche Beacon User Manual Bedienungsanleitung 9 18 en

Pieps GmbH Avalanche Beacon Bedienungsanleitung 9 18 en

User Manual

Download: Black Diamond Equipment DSP01 Avalanche Beacon User Manual Bedienungsanleitung 9 18 en
Mirror Download [FCC.gov]Black Diamond Equipment DSP01 Avalanche Beacon User Manual Bedienungsanleitung 9 18 en
Document ID361912
Application IDhNlvOM24AqN3ZMEQtXVqqA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize277.26kB (3465719 bits)
Date Submitted2003-10-02 00:00:00
Date Available2003-10-02 00:00:00
Creation Date2003-10-01 13:43:38
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2003-10-02 10:27:12
Document TitleBedienungsanleitung_9-18_en.cdr
Document CreatorPScript5.dll Version 5.2
Document Author: EDV1

LCD-Display (back light)
Main switch
OFF-SEND-SEARCH
Lock
Button OPTIONS
Richtungsanzeige
Button MARK
Button SCAN
Number display
Temperatur
Number of burials
Altimeter
Compass
Battery level
Dear winter sports enthusiast,
Congratulations on having purchased a PIEPS avalanche rescue beacon !
100,000 skiers world-wide testify to the quality of this brand, which has been
on the market for nearly 30 years. During this time, PIEPS beacons have
undergone constant improvement. The device you have chosen is a state-ofthe-art piece of equipment. Enhanced by the latest DSP technology (= signal
processing with a Digital Signal Processor) and a triple-antenna system, it not
only offers an exceptional range but also greatly simplifies the rescue
procedure, even in case of multiple victims.
IMPORTANT: Even the PIEPS-DSP beacon cannot protect you against
avalanches. A close study of avalanche prevention techniques is equally
essential, as is regular practising for the eventuality of an avalanche
rescue.
Carrying harness
The PIEPS DSP can be worn directly on your person using the supplied
carrying system. Pass the snap hook of the safety cord through the carry
pouch and attach it to the loop on the rear of the pouch (=safest option).
Alternatively, the PIEPS DSP can be attached to the belt of your ski trousers via
the belt loop, or can be carried in your trouser pocket with or without the
protective pouch. Always make sure, however, that the safety cord is suitably
attached to an eyelet on your clothing to avoid losing the detector.
IMPORTANT: The PIEPS DSP should be worn as close as possible to the
body, and under as many layers of clothing as possible !
LIGHT
1. PRESS
2. MOVE
Battery / switching on / SEND mode
The battery compartment is located at the rear of the housing. The safety screw
connection can be easily opened and closed using a coin.
IMPORTANT: Only use battery type LR03/AAA and always replace all 3
batteries with new ones of the same type. Never use rechargeable
batteries and always change all batteries at the same time!
Depress the main switch lock and push the main switch to the “SEND“ position.
In this mode, the PIEPS DSP will carry out a self-test lasting approx. 5 seconds.
You will then see the send symbol and the remaining % battery voltage in the
display. The LED will also flash synchronously with the transmitter bit timing.
In the event of a device error, a 5-second warning tone sounds. This means the
device is not fit for operation. In this case, contact our customer service
department.
When in the open, make sure the “SEND” mode is selected throughout. The
PIEPS DSP will then transmit continuously any signal it picks up from other
detectors.
IMPORTANT: When switched on, a complex self-testing is done by the
beacon itself, nevertheless a LVS-check stronlgy recommended in
preperation to each tour !
Temperature
Compass
3 x PRESS
Degree - End
Meter +
Meter -
End
Altimeter
Degree +
Bearing compass
End
Beacon with OPTION PACK
By pressing the OPTION switch three times, you can switch from the SEND mode to
the OPTION mode. This enables you to switch between the relevant functions:
! Temperature display
Press SCAN to switch between °C and °F.
! Compass
When new batteries are inserted, the compass has to undergo an internal calibration. This is also
necessary if the device detects strong temperature variations. To start the calibration, press SCAN
(”CAL” flashes). Then rotate the device a full 360°. Finally, press OPTION.
! Bearing compass (direction-finding compass with arrow display)
You can change the bearing direction with SCAN. Select the flashing bearing by pressing MARK (+)
and SCAN (-). To exit, press OPTION.
! Altimeter
You can adapt the altimeter reading to the prevailing air pressure by pressing SCAN. Adjust the
displayed altitude with MARK (+) and SCAN (-). To set the adjustment to zero, press MARK and
SCAN simultaneously. To exit, press OPTION.
By holding down the OPTION key (min. 3 seconds), you can switch back to the SEND
mode. In the OPTION mode, the device does not transmit any signals, and therefore
switches back to the SEND mode automatically after two minutes. If the battery is low,
it switches back after just 30 seconds.
IMPORTANT: Make sure the device stays connected to the harness via the
safety cord at all times !
Single rescue person
50m
Point of impact
û
Point of disapearnce
Multiple rescue persons
Flow direction
50m
EMERGENCY / SEARCH mode
In case of an emergency, the key thing to remember is:
KEEP CALM, OBSERVE, RAISE THE ALARM
Observe the course of the avalanche and make an exact mental note of where the
victim
! was hit by the avalanche (point of impact)
! was last seen (point of disappearance)
The extension of these points indicates the flow direction of the avalanche !
The primary search area is to the left and right of this. When the avalanche stops, the
most experienced member of the group takes control of the search, issuing
instructions from the edge of the avalanche so that another person can mark the
above points (with sticks, etc.).
Depress the main switch lock and push the main switch to the SEARCH position. You
can now begin the PRIMARY SEARCH, in which the device will pick up any signals
from victims within its range. Now scan the primary search area according to the plan
on the left until a steady signal is reported.
IMPORTANT: All participants (including observers) must switch their beacons
to receiving (SEARCH) mode. Always make sure there are no electronic devices
(e.g. mobiles, radios,) or solid metal items in the direct vicinity of the search.
SEARCH mode / rough search
As soon as the PIEPS DSP picks up signals, the approximate distance and direction
appear in the display. The number of victims within the range of the device is
represented by matchstick men.
Number of burials:
one
two
three
four or more
Using the arrow and distance reading, follow the strongest of the received signals
along the field lines. Move in the direction indicated by the PIEPS DSP:
turn LEFT
move STRAIGHT AHEAD
turn RIGHT
The distance reading should become progressively smaller. If it gets larger, switch the
search direction by 180°, i.e. turn round and follow the opposite direction.
IMPORTANT: When working in the SEARCH mode, remain calm and
concentrated, and avoid hasty movements !


Ž
Œ

SEARCH mode / close search
Once you have approached the victim quickly with the rough search, the PIEPS DSP
really comes into its own thanks to its advanced triple-antenna system.
When you are closer than 3 m to the victim, you can start locating the position point by
point. To avoid confusion, the direction display is now suppressed (point 1). Continue
moving in the same direction and follow the plan on the left.
After a certain point, the distance reading will start to increase again (point 2). From
this point, move sideways (90°) without turning your body or the device. If the value
increases unexpectedly, move in the opposite direction (point 3). Along this theoretical
axis, you will find the minimum point of the distance reading (point 4). Mark this point in
the snow and continue at a right angle from here (90°) as already described.
You have now detected the absolute minimum point (point 5) and located the victim.
IMPORTANT: Throughout this procedure, keep the device horizontal in the
same position without rotating it, and keep it as close as possible to the surface
of the snow !
Suppress with
MARK

‘
Locate
third victim

Ž

Locate
second victim
Locate
first victim
Suppress with
MARK
Œ
3 burials are
indicated
SEARCH mode / multiple search
The optimised multiple search, the absolute highlight of the PIEPS DSP, is based on
a separation of signals via the digital signal processor (DSP).
If there are multiple victims, this is clearly indicated by the number of matchstick men.
By default, the PIEPS DSP will automatically search for the strongest signal.
Once the position of the first victim has been located, press the MARK key for approx.
3 seconds without moving away from this point.
This signal is now suppressed and the device will automatically search for the second
strongest signal. In unfavourable circumstances (temporary signal interference), you
may have to repeat this procedure several times. Once a signal has been successfully
suppressed, an outline appears around the matchstick man.
Now continue the search as described above and repeat the procedures until all
transmitters are located.
IMPORTANT: In case of multiple detections involving older analogue devices,
faults may at worst occur which impair the efficiency of the digital signal
separation. In such cases, you may find for a short time that more signals are
displayed than actually exist.
Radius50m
Anzeige:
4 od. Mehr Sender
innerhalb 50m
Ž
Radius 20m

Radius
Anzeige:
2 Sender
innerhalb 20m
Anzeige:
1 Sender
innerhalb 5m
Œ
5m
SEARCH mode / SCAN function
Another highly useful feature of the PIEPS DSP is the SCAN function.
Press the SCAN key in the SEARCH mode and the device will begin scanning the
entire receiving range. During the scan, stand still and hold the device steady.
This will give you an overview of all the victims' devices within the detectable range,
classified according to three groups:
! Reading 1: within a distance of approx. 5m
! Reading 2: within a distance of approx. 20m
! Reading 3: within a distance of approx. 50m
All information from previously suppressed signals is now reset and you can start the
suppression again (MARK).
IMPORTANT: Once you have located all victims, move away from their locations
in a star shape and use the SCAN function to check the scenario again. That way
you can make sure you haven't missed any other victims.
Technical data
Device designation:
Transmission frequency:
Power supply;
Battery lifetimer:
Maximum range:
Earphone socket:
Temperature range:
Weight:
Dimensions (L xWB X H)
PIEPS DSP
457 kHz (internation standard frequency)
3 batteries, Alkaline (AAA), IEC-LR03, 1,5V
Min. 200 h in SEND Mode
60 Metres (digital evaluation)
Stereo earphone 3,5 mm, min. 32 Ohm
-20°C bis +45°C
198 g (incl. batteries)
116 x 75 x 27 mm
Option-Pack
Temperature display
Compass function
Altimeter
-20°C bis +50°C, accuracy ± 3°C
Accuracy ± 8°
Accuracy ± 10 m
Certification / conformity
Warning: Any changes or modifications not expressly approved by Seidel Elektronik,
responsible for compliance, could void the user´s authority to operate this device.
Europa:
Canada:
USA:
Manufacturer:
SEIDEL Elektronik GmbH
Country of manufacture:
Österreich
Device Type:
PIEPS DSP
The device conforms to standard ETS 300817
IC: 4710A-DSP01
FCC ID: REMDSP01
This device conforms to Paragraph 15 of the FCC regulations.
Operation is subject to the following two conditions:
1) This device may not cause harmful interference, and
2) this device must accept any interference received, including interfernce that may
cause undesired operation
Warranty conditions:
The device is guaranteed by the manufacturer against defects in material and
workmanship for a period of five years from the date of purchase.
This warranty does not apply to damage caused by incorrect use, dropping or
dismantling of the device by unauthorised persons.
Any further warranty or liability for consequential damage is expressly excluded.
Warranty claims should be addressed - enclosing the receipt of purchase - to the
relevant sales outlet or directly to STUBAI Werkzeugindustrie.
Manufacturer:
SEIDEL Elektronik GmbH
Frauentalerstrasse 100
A-8530 Deutschlandsberg, Österreich
Email: office@seidel.at
International exclusive distribution and service:
STUBAI Werkzeutindustrie Reg.Gen.m.b.H.
Dr.Kofler Strasse 1
A-6166 Fulpmess, Österreich
EMail: office@stubai.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 21
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:d1890ae4-f4bb-11d7-aed9-00c0dfef6518
Producer                        : Acrobat Distiller 5.0 (Windows)
Create Date                     : 2003:10:01 13:43:38Z
Modify Date                     : 2003:10:02 10:27:12+02:00
Metadata Date                   : 2003:10:02 10:27:12+02:00
Creator Tool                    : PScript5.dll Version 5.2
Document ID                     : uuid:d1890ae1-f4bb-11d7-aed9-00c0dfef6518
Format                          : application/pdf
Creator                         : EDV1
Title                           : Bedienungsanleitung_9-18_en.cdr
Author                          : EDV1
EXIF Metadata provided by EXIF.tools
FCC ID Filing: REMDSP01

Navigation menu