Blinq Networks 00000001 Point-to-multipoint wireless bridge User Manual
Blinq Wireless Inc. Point-to-multipoint wireless bridge Users Manual
Users Manual
BLiNQ Networks Inc. X-100 Intelligent Wireless Backhaul System User Guide Release 1.0 Issue 01 February 2013 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Disclaimer The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Additionally, BLiNQ Networks makes no representations or warranties, either expressed or implied, regarding the contents of this product. BLiNQ Networks shall not be liable for any misuse regarding this product. The information in this document is subject to change without notice. Revision History Date Issue Reason for Issue February 2013 01 General Availability (GA) release. Contact Information: BLiNQ Networks Inc. 400 March Road, Suite 240 Ottawa, ON K2K 3H4 Web Site: http://www.blinqnetworks.com Sales Inquiries: Email: Telephone: sales@blinqnetworks.com 1-613-599-3388 x280 Web: Email: Telephone: http://www.blinqnetworks.com/support support@blinqnetworks.com 1-613-599-3388 x270 Support: © Copyright 2012-2013 BLiNQ Networks Inc. All rights reserved. CONFIDENTIAL INFORMATION RESTRICTED USE AND DUPLICATION The information contained herein is the property of BLiNQ Networks Inc. and is strictly confidential. Except as expressly authorized in writing by BLiNQ Networks Inc., the holder shall keep all information contained herein confidential, shall disclose it only to its employees with a need to know, and shall protect it, in whole or in part, from disclosure and dissemination to third parties with the same degree of care it uses to protect its own confidential information, but with no less than reasonable care. Except as expressly authorized in writing by BLiNQ Networks Inc., the holder is granted no rights to use the information contained herein. BLiNQ and BLiNQ Networks Inc. corporate logo are trademarks of BLiNQ Networks Inc. All other trademarks used in this document are the property of their respective owners. The use of the word partner does not imply a partnership relationship between BLiNQ and any other company. Confidential - Restricted Use and Duplication Page 1 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Table of Contents X-100 System Overview ........................................................................................................................ 6 X-100 System Description ..................................................................................................................... 9 Technical Specifications ...................................................................................................................... 12 3.1 System Parameters ..................................................................................................................... 12 3.2 OFDMA and Frame Parameters .................................................................................................. 13 3.3 Integrated RBM Antenna ............................................................................................................ 13 3.4 System Enclosure ........................................................................................................................ 15 Link Budget and System Gain.............................................................................................................. 16 4.1 System Trade-offs ....................................................................................................................... 17 System Synchronization ...................................................................................................................... 19 5.1 Synchronization Services ............................................................................................................ 19 System Throughput ............................................................................................................................. 21 Element and Network Management .................................................................................................. 23 Ethernet Bridge Support ..................................................................................................................... 26 Installation Planning............................................................................................................................ 27 10 Using the X-100 WebUI ................................................................................................................... 28 10.1 Requirements .............................................................................................................................. 28 10.2 Common X-100 WebUI Page Items............................................................................................. 29 10.3 Configuring Hub Modules ........................................................................................................... 30 10.3.1 Logging In ............................................................................................................................ 31 10.3.2 System Overview Page ........................................................................................................ 32 10.3.3 Setup Page (System) ........................................................................................................... 33 10.3.4 Setup Page (Radio Interface) .............................................................................................. 34 10.3.5 Bridge Page ......................................................................................................................... 35 10.3.6 RBMs Page (RBM General) .................................................................................................. 36 10.3.7 RBMs Page (Default Service) ............................................................................................... 37 Confidential - Restricted Use and Duplication Page 2 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.3.8 RBMs Page (RBM List) ......................................................................................................... 39 10.3.9 Performance Page (Ethernet) ............................................................................................. 40 10.3.10 Performance Page (RBMs) .............................................................................................. 40 10.3.11 Events Page (Alarms) ...................................................................................................... 42 10.3.12 Events Page (History) ...................................................................................................... 43 10.3.13 Admin Page (Management Interface)............................................................................. 43 10.3.14 Admin Page (User Manager) ........................................................................................... 44 10.3.15 Admin Page (SNMP Settings) .......................................................................................... 45 10.3.16 Admin Page (Software Upgrade) .................................................................................... 46 10.3.17 Admin Page (Configuration Management) ..................................................................... 47 10.3.18 Admin Page (Syslog Server)............................................................................................. 48 10.4 Configuring RBMs........................................................................................................................ 49 10.4.1 Logging In ............................................................................................................................ 50 10.4.2 System Overview Page ........................................................................................................ 50 10.4.3 Setup Page (System) ........................................................................................................... 51 10.4.4 Setup Page (Radio Interface) .............................................................................................. 51 10.4.5 Performance Page ............................................................................................................... 52 10.4.6 Events Page ......................................................................................................................... 52 10.4.7 Admin Page ......................................................................................................................... 52 11 Alarms and Events (Fault Management)......................................................................................... 53 12 Using the X-100 Command Line Interface ...................................................................................... 56 12.1 Overview ..................................................................................................................................... 56 12.2 Identify Command Context ......................................................................................................... 56 12.3 Logging On to the X-100 CLI ........................................................................................................ 57 12.4 Privileged EXEC Commands ........................................................................................................ 57 12.5 Global CONFIG Commands ......................................................................................................... 58 12.5.1 Radio CONFIG Mode ........................................................................................................... 59 12.5.2 User CONFIG Mode ............................................................................................................. 59 Confidential - Restricted Use and Duplication Page 3 of 91 Issue 01 BLiNQ Networks Inc. 12.5.3 X-100 User Guide Release 1.0 RBM CONFIG Mode (Hub Modules Only) ........................................................................... 60 12.6 X-100 CLI Command Structure .................................................................................................... 62 12.7 X-100 CLI Command Line Prompts.............................................................................................. 63 12.8 X-100 CLI Keywords and Parameters .......................................................................................... 64 12.8.1 Keywords............................................................................................................................. 64 12.8.2 Parameters .......................................................................................................................... 64 12.8.3 Keywords and Parameters Together .................................................................................. 65 12.9 Saving Configuration Changes Made Through the X-100 CLI .................................................... 65 12.10 Writing and Running X-100 CLI Scripts.................................................................................... 67 12.11 Using Help ............................................................................................................................... 67 12.11.1 ? (Question Mark Key) .................................................................................................... 68 12.11.2 help Command ................................................................................................................ 69 12.11.3 Partial-keyword.................................................................................................... 70 12.12 13 Upgrading System Software Through the X-100 CLI ............................................................... 71 System Provisioning ........................................................................................................................ 73 13.1 Initial System Setup and IP Configurations ................................................................................. 73 13.2 Adding Users ............................................................................................................................... 76 13.3 Provisioning Default Versus Individual Service Flows ................................................................. 77 13.4 Configuring and Adding Individual RBMs.................................................................................... 77 14 Preambles, Flows, and Network Provisioning................................................................................. 83 14.1 Preamble Functional Description................................................................................................ 83 14.2 Preamble Operational Description ............................................................................................. 84 14.3 Provisioning Preambles ............................................................................................................... 84 14.4 Provisioning HM Service Flow Definitions .................................................................................. 87 14.5 Provisioning Multiple Clusters Within the Same Area ................................................................ 87 15 Appendices ...................................................................................................................................... 89 15.1 BLiNQ Wireless Devices and RF Safety........................................................................................ 89 15.2 List of Acronyms .......................................................................................................................... 90 Confidential - Restricted Use and Duplication Page 4 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 List of Figures FIGURE 1 BLINQ X-100 SYSTEM IN A WIRELESS BACKHAUL APPLICATION ....................................................................................6 FIGURE 2 BLINQ X-100 HUB MODULE (HM) AND REMOTE BACKHAUL MODULE (RBM) ...............................................................8 FIGURE 3 HORIZONTAL ANTENNA PATTERN (PORT 1) FOR 3.5 GHZ BAND ...................................................................................14 FIGURE 4 PERFORMANCE VERSUS DISTANCE FOR 256 QAM 5/6 MCS ......................................................................................18 FIGURE 5 SYSTEM SYNCHRONIZATION THROUGH GPS .............................................................................................................20 FIGURE 6 SYSTEM SYNCHRONIZATION THROUGH IEEE 1588V2 ................................................................................................20 FIGURE 7 MODULE CASING LABEL EXAMPLE .........................................................................................................................27 List of Tables TABLE 1 OVERVIEW OF MAIN X-100 SYSTEM CHARACTERISTICS .................................................................................................7 TABLE 2 GENERAL X-100 SYSTEM PARAMETERS ....................................................................................................................12 TABLE 3 OFDMA AND FRAME PARAMETERS FOR A 10 MHZ CHANNEL BANDWIDTH ....................................................................13 TABLE 4 INTEGRATED ANTENNA SPECIFICATIONS IN THE 3.65 GHZ BAND ...................................................................................14 TABLE 5 LINK BUDGET FOR X-100 SYSTEM AT 3.65 GHZ IN A 2X2 MIMO-SM OPERATION ..........................................................16 TABLE 6 NLOS RANGE AT 3.65 GHZ FOR 2X2 MIMO-SM MODE ...........................................................................................17 TABLE 7 SYSTEM GAIN FOR LOWER MODULATION AND CODING SCHEMES; INCLUDES MAXIMAL RATIO COMBINING (MRC) GAIN ........17 TABLE 8 THROUGHPUT PERFORMANCE FOR CYCLIC PREFIX OF 1/8 ............................................................................................21 TABLE 9 THROUGHPUT PERFORMANCE FOR CYCLIC PREFIX OF 1/16 ..........................................................................................22 TABLE 10 LIST OF ALARMS .................................................................................................................................................53 TABLE 11 LIST OF EVENTS ..................................................................................................................................................55 TABLE 12 HELP COMMANDS ..............................................................................................................................................67 TABLE 13 LIST OF ACRONYMS .............................................................................................................................................90 Confidential - Restricted Use and Duplication Page 5 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 1 X-100 System Overview Figure 1 BLiNQ X-100 System in a Wireless Backhaul Application BLiNQ Networks is a pioneer of next-generation wireless backhaul solutions that feature intelligent systems capable of adapting to the radio frequency environment to maximise capacity and performance. The BLiNQ X-100 system operates in the sub 6 GHz licensed frequency bands and are designed for NonLine-of-Sight (NLOS) operation by incorporating advanced physical layer and medium access control layer algorithms and techniques. BLiNQ has developed proprietary interference mitigation algorithms and incorporated self-organizing network techniques into its solutions to increase capacity and reliability beyond that of ordinary backhaul solutions. This is because in a NLOS environment, interference and shadowing are the two main reasons that limit capacity and link reliability. Mitigating interference and enhancing signal reliability maximizes system performance. The X-100 system delivers 8 b/s/Hz spectral efficiency. The system is designed for use in multiple applications that includes mobile backhaul, optical fibre cable extension and corporate and enterprise data backhaul services by providing over 80 Mbps of throughput in a 10 MHz channel. The interference mitigation technology allows network operators to deploy a greater density of wireless links in a small spectrum allocation (such as 10 or 20 MHz). The X-100 system operates in non-exclusive licensed Time Division Multiplexing (TDD) band 3.65 – 3.7 GHz in both Point-to-Point (PTP) and Point-to-Multipoint (PMP) configurations. Some of the main product characteristics are shown in Table 1. The X-100 system incorporates Multiple Input Multiple Output (MIMO technology and operates at high Modulation and Coding Scheme (MCS) rates to provide high capacity. In addition, the product incorporates BLiNQ’s interference management techniques which include multiple power control algorithms to maximize performance in dense networks. The X-100 system using a 10 MHz channel employs a large number of sub-carriers (1024) which helps Confidential - Restricted Use and Duplication Page 6 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 optimize bandwidth use. A large number of sub-carriers yields a long symbol time because the minimum symbol time is inversely proportional to the sub-carrier bandwidth. Transmitted signals are subject to time delay dispersion because of multiple paths. While the most direct path might involve no reflections, other paths involve one or more thus presenting the signal with longer path lengths and hence longer transit times. To prevent interference between successive symbols due to this dispersion, a gap called the cyclic prefix (or guard time) is added to each symbol. Dispersion dictates a cyclic prefix length of about 3-5 µsec in urban areas where small cells are deployed. For short symbol times on the order of a few µsec the added cyclic prefix would substantially cut into the useful bandwidth. For the longer symbol times used by the X-100 system the cyclic prefix is only a small fraction of the total bandwidth. Table 1 Overview of Main X-100 System Characteristics Duplex Mode Time Division Multiplexing (TDD) Physical Layer/Antenna System 1024 sub-carrier OFDM – NLOS 2x2 MIMO Operation Configuration Point-to-Point Point-to-Multipoint Throughput Total 83 Mbps shared between DL and UL depending on user defined TDD DL/UL traffic ratios; e.g. DL 53 Mbps for 65:35 traffic ratio (user selectable in X-100 WebUI through Setup Page). Frequency of Operation 3.65 – 3.7 GHz (non-exclusive licensed band) Channel Bandwidth 10 MHz Network Interface Ethernet (Fiber optional for Hub) Quality of Service (QoS) Two classes: Guaranteed Bit Rate (GBR) and Best Effort (BE) Form Factor All-outdoor; zero-footprint Confidential - Restricted Use and Duplication Page 7 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Hub Module (HM) (The RBM mechanical enclosure is similar to the Hub Module, except that the RF connectors, the SFP receptacle and the integrated GPS antenna are absent). Remote Backhaul Module (RBM) Figure 2 BLiNQ X-100 Hub Module (HM) and Remote Backhaul Module (RBM) The X-100 system consists of the following modules: • Hub Modules (HMs): These are sector controllers that control several RBMs. Hub Modules feature two RF connectors for an external user-defined sectored antenna. • Remote Backhaul Modules (RBMs): These are subscriber units that are installed outdoors on customer premises, including public infrastructure assets such as light and utility poles in mobile backhaul applications. The RBMs feature an integrated antenna. • Configuration System: This consists of the X-100 WebUI tool and X-100 CLI for configuration management, as well as fault and performance management. Note: Fault and performance management is also made available through a standard Simple Network Management Protocol (SNMPv2C/v3) interface to existing third-party managing applications such as element/network management systems (EMSs/NMSs). The X-100 system has a small, all-outdoor, zero-footprint form factor that can be easily deployed on towers, poles, building sidewalls, or rooftops unobtrusively. Confidential - Restricted Use and Duplication Page 8 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 2 X-100 System Description The BLiNQ X-100 system is designed to meet the requirements of network operators for high capacity and reliability in small cell base station backhaul applications, as well as in a number of other applications. The system can function either as Point-to-Point (PTP) or Point-to-Multipoint (PMP) wireless Ethernet bridge equipment. Some of the main product characteristics include: Orthogonal Frequency-Division Multiple Access (OFDMA) Physical Layer: This includes 1024 subcarriers (data, pilot and guard-band). The OFDMA physical layer coupled with multiple antenna technology provides robust performance in a non-line-of-sight (NLOS) environment. Time Division Duplex (TDD): The X-100 system features TDD access mode with variable frame length (user selectable 3.125 and 5 msec). The TDD frame includes the downlink and uplink sub-frames. Each subframe includes a number of OFDM symbols which are assigned to different Remote Backhaul Modules (RBMs). The length of each sub-frame determines the traffic ratio for downlink and uplink traffic and is a user settable parameter. Note: Frame length of 3.125 msec not supported in current release. Multiple Input Multiple Output (MIMO): The X-100 system features spatial multiplexing on two antennas (2x2) for high capacity. Adaptive Modulation with Link Adaptation: The X-100 system supports QPSK, 16QAM, 64QAM and 256QAM on both the downlink and uplink path to achieve high capacity in limited channel bandwidth (83 Mbps Ethernet layer throughput in a 10 MHz channel for combined downlink and uplink traffic). Note: Total 71.5 Mbps throughput is in effect this release. Intelligent Interference Management: The X-100 system implements the BLiNQ proprietary Managed Adaptive Resource Allocation (MARA) algorithm to identify the links with highest interference in the backhaul network and to manage the transmission of backhaul nodes to eliminate interference. The MARA algorithm improves capacity and link reliability. It also reduces the operational and capital costs associated with site design, deployment and optimization activities as interference is automatically identified and mitigated, thereby reducing the design and optimization effort required from RF engineers and field technicians. Backhaul Self-Organizing Networks: The X-100 system periodically characterizes the radio frequency (RF) environment in the backhaul network to account for changes such as deployment of new sites or changes that affect interference (for example, foliage, variation between seasons, new building construction). The measurements, termed RF Environment Characterization (RFEC), are typically scheduled by the operator to run at a certain time of the day and used in MARA/power control algorithms. Power Control: The X-100 system incorporates power control on both the downlink and uplink streams to minimize interference at physical layer and maximize capacity. Two types of power control are implemented: link level and network level. Link-level power control optimizes the power for a certain link to meet its capacity requirements, whereas network-level power control optimizes link power based on network level constraints to maximize network performance. Confidential - Restricted Use and Duplication Page 9 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Antennas: The X-100 Remote Backhaul Modules (RBMs) integrate a specially designed slant-45 crosspolarized antenna to reduce interference and provide high co-polar isolation between the two branches. For example, the sidelobe level in the azimuthal plane is 8 dB below European Telecommunications Standards Institute (ETSI) Directory Number (DN) 4and 5 mask requirements and 15 dB below ETSI DN 2 mask requirements. Point-to-Multipoint (PMP) with Dynamic Bandwidth Allocation: The X-100 system can operate in PTP or PMP configurations with up to four RBMs. The capacity allocated to each RBM is variable according to subscriber requirements (for example, compact base station). Quality of Service (QoS): Two levels of QoS are defined in the X-100 system for traffic classification: Guaranteed Bit Rate and Best Effort. Through service-level agreements (SLAs), customers can subscribe to the service class desired for their application. Service Class GBR BE Description Guaranteed Bit Rate Provides the most stringent scheduling, maintaining guarantees on throughput, latency, and jitter to the levels necessary for synchronization/timing packets such as NTP v4.0 and Time Division Multiplexed (TDM) services. Best Effort No guaranteed minimum throughput. For data streams for which no minimum service level is required and therefore may be handled on a space-available basis. Traffic Classification: Ethernet traffic is classified by the Layer 2 (L2) Media Access Control (MAC) source and destination address, 802.1p/Q settings, differentiated services code point (DSCP) and type of service (ToS) bits, L3 IP source and destination address, and protocol. Form Factor: The all-outdoor, zero-footprint Hub Module (HM) and RBMs are built to IP67 requirements for operation in tough environments with the capability to handle large variations in temperature from extreme cold to extreme heat. High-level of Integration: The X-100 systems are highly integrated and include: • The RBM which integrates a high-gain 17 dBi antenna. The RBM derives its synchronization from the Hub Module. • The HM which integrates a complete Global Positioning System (GPS) antenna and receiver with high holdover (10 minutes). Therefore, no additional synchronization module is required for the X-100 system, which reduces the total cost of ownership of the solution while simplifying and accelerating installation. The X-100 system is small in size (31x21x8 cm) and low in weight (3.5 kg) so it can be easily mounted on the network operator’s existing tower assets. The small size and weight allows quick deployment of the RBMs at customer premises in different enterprise/corporate data backhaul applications or other types of industrial and commercial applications. All modules offer a standard RJ45 Ethernet port, while the Hub Module offers optional optical connectivity through a field-installable SFP optical transceiver module. Confidential - Restricted Use and Duplication Page 10 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 The BLiNQ X-100 system also provides the following network management features: • Fault and Performance Management: The X-100 system incorporates fault and performance management through a standard Simple Network Management Protocol (SNMP)v2c interface. For this BLiNQ provides its Management Information Base (MIB) to network operators for integration into existing third-party managing applications such as element/network management systems (EMSs/NMSs), thereby providing access to key information on X-100 service availability and performance. • Configuration Management: BLiNQ products are designed to minimize the configuration effort by the network operator. For example, when deployed in the field, the X-100 system can obtain its IP address through DHCP rather than have it statically assigned by the user. Further, the X100 system provides a web-based configuration tool called the X-100 WebUI and a standard Command Line Interface (CLI) that run directly on the X-100 equipment. • Software Upgrade: BLiNQ products are field upgradeable through remote download and activation of software release upgrades. Confidential - Restricted Use and Duplication Page 11 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 3 Technical Specifications 3.1 System Parameters Table 2 shows general X-100 system parameters. Table 2 General X-100 System Parameters Access Technology Orthogonal Frequency-Division Multiplexing (OFDM) Non-Line-ofSight (NLOS) RF Bands 3.65 – 3.7 GHz Channel Size (Bandwidth) 10 MHz Data Rate Up to 83 Mbps (Layer 2/Ethernet) Tx Power 23 dBm / 0.2 W (per antenna port, two ports) Duplex Mode Time Domain Duplex (TDD) Modulation & Coding Quadrature Phase Shit Keying (QPSK), 16/64/256 QAM; Bidirectional Dynamic Adaptive Convolutional Turbo Codes Advanced Antenna Systems 2x2 Multiple Input Multiple Output (MIMO) / Spatial Multiplexing Antenna Remote Backhaul Module (RBM): Integrated 17 dBi gain Hub Module (HM): External antenna Synchronization Global Positioning System (GPS); IEEE 1588v2 Encryption AES-128 Network Interface1 Copper: RJ45 100BaseT Ethernet Fiber (Optional on HM): Optical Gigabit Ethernet Network Attributes Ethernet bridge, 802.1Q, 802.1ad, DSCP/ToS/802.1p (IPv4/IPv6) and QinQ Tagging Power Requirement -48 VDC Power Consumption 35 W (typical); 65 W (max) Operating Temperature -40°C to 55°C Weight <3.8 kg / 7.7 lbs Dimensions 31 x 21.8 x 8.3 cm Humidity Up to 95% non-condensing Compliance EMC: FCC Part 15, EN 301 489-1 RF: ETSI EN 302 326, EN 302 544, ECC/REC/(04)05, FCC Part 27, FCC Part 90 Safety: IEC, EN and UL/CSA 60950 Environmental: IP 67 System Configuration X-100 WebUI/X-100 CLI Fault and Performance Simple Network Management Protocol (SNMP)v2C/v3 Management The copper Ethernet interface on the HM has priority over the fiber optical Gigabit Ethernet interface. If, for example, an on-site technician connects to the HM locally by the copper interface while the HM is providing network services to its users through the fiber interface, the fiber interface is then disabled and taken out of service. Network service through the fiber interface is restored when the copper interface is disconnected. Confidential - Restricted Use and Duplication Page 12 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 3.2 OFDMA and Frame Parameters Orthogonal Frequency-Division Multiple Access (OFDMA) and Frame Parameters for 10 MHz channel bandwidth option are shown in Table 3. The frame duration or size is a user settable feature in the X-100 WebUI (through the Setup Page for the Radio Interface) and is part of system configuration. Table 3 OFDMA and Frame Parameters for a 10 MHz Channel Bandwidth 1024 Number of Subcarriers Data Carriers 720 Pilot Subcarriers 120 10.9375 KHz Subcarrier Spacing Frame Duration or Size Frames per Second Cyclic Prefix Number of Symbols 1/8 5 msec 3.125 msec 200 320 1/16 48 51 1/81 30 1/16 32 3.3 Integrated RBM Antenna The Remote Backhaul Module (RBM) features a high-quality antenna that has very low side lobes (-30 dBc) to minimize interference. This allows greater scalability of deployment of BLiNQ X-100 system modules in a market and allows smaller frequency reuse factor for higher spectrum utilization. Figure 3 shows the antenna patterns and compares them to standard off-the-shelf antennas typically available in commercial systems such as WiMAX Customer Premise Equipment (CPE) and other backhaul devices in the 3.5 GHz band. High gain (17 dBi) and directivity (narrow horizontal beamwidth of 22 degrees) work to increase system gain and reduce the interference transmitted and received at angles away from the boresight of the antenna. This is critical for small cell mobile backhaul applications as the backhaul network is interference limited. It also works to increase the range in other types of applications where distance is the overriding factor. Confidential - Restricted Use and Duplication Page 13 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Mask for off the shelf antennas BLiNQ’s RBM Antenna Performance Figure 3 Horizontal antenna pattern (Port 1) for 3.5 GHz band Table 4 Integrated Antenna Specifications in the 3.65 GHz Band Gain 17.0 ± 1 dBi Voltage Standing Wave Ratio (VSWR) 1.8:1 (max) -3 dB Azimuth Beam Width 22.5° ± 2° -3 dB Elevation Beam Width 27° ± 3° AZ and EL Beam Squint ±2° Polarization Dual Slant ± 45° Port To Port Isolation 22 dB (min), 28 dB (typ) Front to Back (F/B) Ratio -45 dB (typ) Confidential - Restricted Use and Duplication Page 14 of 91 1.5:1 (typ) Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 3.4 System Enclosure The enclosure for both the Hub and RBM is a rugged IP67 casing supplied with an optional mounting bracket with both horizontal and vertical tilt capabilities to mount the unit on towers, poles, and building side walls while allowing full flexibility in the range of orientation to establish best connectivity between the Hub and RBMs. In Figure 2, the mechanical enclosure for the HM has two RF port connectors for an external userdefined sectored antenna. Two connectors are also provided on the back of the HM: a -48 VDC power connector, and an RJ45 connector for 1000 BaseT copper Ethernet network connectivity. An optional small form-factor pluggable (SFP) fiber connector for optical Gigabit Ethernet network connectivity can also be installed in the field. An integrated Global Positioning System (GPS) antenna is shown on the top (flat square patch). Therefore, no additional synchronization equipment is required to reduce total cost of ownership. Note: The copper Ethernet interface on the HM has priority over the fiber optical Gigabit Ethernet interface. If, for example, an on-site technician connects to the HM locally by the copper interface while the HM is providing network services to its users through the fiber interface, the fiber interface is then disabled and taken out of service. Network service through the fiber interface is restored when the copper interface is disconnected. The RBM is the exact same size and dimension as the HM. It differs in that the antenna is integrated, hence there are no external RF connectors. Also, the RBM does not include an integrated GPS antenna as synchronization is available from the HM. There is also no provision for an SFP fiber connector. Confidential - Restricted Use and Duplication Page 15 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 4 Link Budget and System Gain Table 6 lists the link budget for the BLiNQ X-100 system at 3.65 GHz in a 2x2 Multiple Input Multiple Output-Spatial Multiplexing (MIMO-SM) operation. The X-100 system provides very high system gain (134 dB for 256 Quadrature Amplitude Modulation [QAM] 5/8 Modulation and Coding Scheme [MCS]). This is due to a relatively high transmit power for both the Hub and Remote Backhaul Modules (RBMs) (27 dBm per antenna port; a total of 30 dBm). The X-100 system gain allows network design to incorporate a high fade margin to combat shadow and fast fading and enable high link availability in urban areas which is important in small cell mobile backhaul applications. Alternatively, high system gain translates into longer range in applications where this is required. Table 5 Link Budget for X-100 System at 3.65 GHz in a 2x2 MIMO-SM Operation Transmitter 256QAM 7/8 256QAM 6/8 256QAM 5/8 64QAM 5/6 64QAM 3/4 64QAM 2/3 64QAM 1/2 Power per Stream 23 23 23 23 23 23 23 dBm Hub Antenna Gain 17 17 17 17 17 17 17 dBi Tx Losses 0.25 0.25 0.25 0.25 0.25 0.25 0.25 dB EIRP (per Stream) 39.8 39.8 39.8 39.8 39.8 39.8 39.8 dBm Receiver 256QAM 7/8 256QAM 6/8 256QAM 5/8 64QAM 5/6 64QAM 3/4 64QAM 2/3 64QAM 1/2 Units -174 -174 -174 -174 -174 -174 -174 dBm/Hz dB 10.9375 10.9375 10.9375 10.9375 10.9375 10.9375 10.937 kHz -129.6 -129.6 -129.6 -129.6 -129.6 -129.6 -129.6 dBm 17 17 17 17 17 17 17 dBi Required RX Power per Branch -65.5 -74.4 -75.5 -76.8 -78.7 -79.7 -83.6 dBm System Gain (dB) 122.3 131.2 132.3 133.6 135.5 136.5 140.4 dB Thermal Noise Noise Figure Noise BW (per Tone) Receive Noise Floor (per Tone) RBM Antenna Gain Confidential - Restricted Use and Duplication Page 16 of 91 Units Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Table 7 shows the system gain at 3.65 GHz for different modulation rates and the associated capacity and Non-Line-of-Sight (NLOS) distance for 99.9% availability in urban and rural environments. Modulation Table 6 NLOS Range at 3.65 GHz for 2x2 MIMO-SM Mode NLOS (m) (99.9% Link Availability) System Gain (dB) Capacity (Mbps) Urban (SUI 5/6) Rural (SUI 1/2) 256QAM7/8 122.25 83 243 425 256QAM6/8 131.15 71 373 700 256QAM5/8 132.25 61 454 880 64QAM5/6 133.55 59 483 946 64QAM3/4 135.45 53 529 1,052 64QAM2/3 136.45 47 555 1,113 64QAM1/2 140.35 35 669 1,384 The system gain for maximum distance calculations for the lower modulation schemes is shown in Table 8 for a single antenna operation (that is, Single Input Single Output [SISO]) with receive diversity gain of 3 dB included to account for 2-branch maximal ratio combining. Table 7 System Gain for Lower Modulation and Coding Schemes; Includes Maximal Ratio Combining (MRC) Gain Modulation 16QAM3/4 16QAM2/3 QPSK3/4 Required Rx Power (dBm) System Gain (dB) -85 -88.7 -91.3 144.75 148.45 151.05 4.1 System Trade-offs Range, capacity and reliability are three factors that can be traded off against each other. The higher the fade margin, the lower the reach of the X-100 is to achieve a certain capacity target. For example, Figure shows a system gain of 136 dB for 256-QAM 5/8 MCS which results in a throughput of 61 Mbps. Budgeting 25 dB of fade margin for 99.9% availability results in a maximum allowable path loss of 13625 = 111 dB, or a corresponding range of just over 400 m. Higher reliability is possible by using a larger fade margin which reduces the distance. Alternatively, higher reliability can be achieved at this range with a lower MCS such as 64-QAM 3/4. Confidential - Restricted Use and Duplication Page 17 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Figure 4 Performance Versus Distance for 256 QAM 5/6 MCS The BLiNQ proprietary Managed Adaptive Resource Allocation (MARA) interference management technology built into the X-100 system contributes to increasing the link availability while also providing higher capacity. Confidential - Restricted Use and Duplication Page 18 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 5 System Synchronization The X-100 system is a Time Division Multiplexed (TDD) radio system. Therefore, X-100 networks require proper synchronization of the air interface to provide optimal service. The X-100 system is designed to provide flexible synchronization options as well as provide a high-performance extension to existing synchronization networks to provide quality clock services to downstream devices such as small-cells. The X-100 system is synchronized at the Hub Module (HM) using one of two standard synchronization mechanisms: Global Positioning System (GPS) or IEEE 1588v2. When configured to synchronize on GPS, the X-100 system uses its internal GPS antenna and receiver module to synchronize to the GPS network. This allows all X-100 HMs deployed in the network to accurately synchronize their transmit and receive operations on the air interface. The GPS system also allows the X-100 system to determine accurate time of day and date information. This time information together with a user configured timezone setting is used to inform time across the system and is essential in functions such as fault management (for example, event and alarm timestamping) and historical performance (for example, performance indicator processing and performance file creation). Time information is automatically transmitted from the HM to any Remote Backhaul Module (RBM) associated to that HM. When configured to synchronize on IEEE 1588v2, the X-100 system synchronizes to IEEE 1588v2 master clocks deployed on the operator network. The HM can either be configured to use a specific master clock (by providing the master clock identity) or can perform the standard Best Master Clock (BMC) Algorithm to select the best available master clock on the network. Just like GPS, the IEEE 1588v2 infrastructure allows the HM to precisely synchronize its air interface. It also provides accurate time of day information. The X-100 system includes a high performance crystal oscillator that allows it to maintain its clock properties (Holdover) even if the primary clock reference (that is, GPS or IEEE 1588v2) is no longer available. The system is designed to provide a Holdover period of 10 minutes. During this time the radio is operational and the system attempts to recover its primary clock source. If the clock source has not be reacquired after the Holdover period expires, the system is deemed “Not synchronized” and therefore ceases radio operation so as to not interfere with other deployed X-100 systems. 5.1 Synchronization Services Based on its high-performance internal synchronization mechanisms, the X-100 system is designed to provide in-band synchronization services to downstream devices using the IEEE 1588v2 protocol. The HM and RBMs include IEEE 1588 capable Ethernet PHY modules that provide accurate hardware based timestamping, necessary for high-performance synchronization applications. The X-100 system supports two operating modes for synchronization services, depending on the primary clock reference used at the HM: GPS or IEEE 1588v2.. Confidential - Restricted Use and Duplication Page 19 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 In the first mode, the HM uses the GPS as its primary clock reference. Based on the intrinsic synchronized nature of the HM to RBM protocol, the clock reference is accurately transported at the RBM and therefore the entire cluster implements the behavioral requirements of an IEEE 1588v2 master clock. The X-100 system allows the configuration of the main IEEE 1588v2 master clock parameters such as transport protocol and messaging intervals. Figure 5 System Synchronization Using GPS In the second mode, the HM is configured to synchronize using the IEEE 1588v2 network, making the X-100 cluster effectively behave as an IEEE 1588v2 boundary clock. The system provides master clock services at the RBM Ethernet port, and advertises itself as a boundary clock that uses the same grandmaster clock as the HM parent clock. In this mode, all upstream IEEE 1588 messaging is dropped at the HM. Figure 6 System Synchronization Using IEEE 1588v2 Confidential - Restricted Use and Duplication Page 20 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 6 System Throughput The X-100 system uses time division duplexing (TDD) access mode, employing a single frequency for both transmit and receive paths. The throughput for the downlink and uplink depends on several usersettable parameters such as frame duration or size (3.125 or 5 ms), downlink-to-uplink frame bandwidth ratio (option of 50:50 or 65:35), and the number of Remote Backhaul Modules (RBMs) connected to a Hub Module (HM). Furthermore, the system throughput depends on the Modulation and Coding Rate (MCS) and whether the Multiple Input Multiple Output-Spatial Multiplexing (MIMO-SM) mode is active, both of which vary according to link and signal conditions. Note: Frame length of 3.125 msec not supported in current release. Tables 9 and 10 show the maximum link throughput for the X-100 system assuming 10 MHz channel MIMO operation which doubles the channel throughput by transmitting two independent codewords on each antenna. Note: System throughput is set using the X-100 WebUI Setup Page for the Radio Interface. See 10.3.4 for details. Table 8 Throughput Performance for Cyclic Prefix of 1/8 TDD Frame Length, DL/UL 5 ms, 20/20 3.125 ms, 12/10 MCS 1 RBM 2 RBMs 3 RBMs 4 RBMs 1 RBM 2 RBMs 3 RBMs 4 RBMs 256-QAM 7/81 76.0 73.1 70.0 67.0 64.5 60.6 54.9 49.9 256-QAM 6/8 65.0 62.6 60.1 57.6 55.3 52.1 47.1 42.5 64-QAM 5/6 54.2 51.9 49.8 47.7 45.9 43.2 39.0 35.1 64-QAM 3/4 48.7 46.8 44.6 42.7 41.1 38.7 34.9 31.4 64-QAM 2/3 43.3 41.5 39.9 37.8 36.7 34.5 30.9 27.7 16-QAM 3/4 32.3 31.0 29.6 28.4 27.5 25.8 23.1 20.3 16-QAM 1/2 21.5 20.5 19.6 18.5 18.3 17.0 15.0 13.0 QPSK 3/4 16.1 15.2 14.5 13.5 13.5 12.6 10.9 9.3 Confidential - Restricted Use and Duplication Page 21 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Table 9 Throughput Performance for Cyclic Prefix of 1/16 TDD Frame Length, DL/UL 5 ms, 22/22 3.125 ms, 12/12 MCS 1 RBM 2 RBMs 3 RBMs 4 RBMs 1 RBM 2 RBMs 3 RBMs 4 RBMs 256-QAM 7/81 83.5 80.4 77.1 73.7 70.4 67.4 64.4 54.5 256-QAM 6/8 71.5 68.9 66.2 63.4 60.3 57.9 55.5 46.4 64-QAM 5/6 59.6 57.2 54.8 52.5 50.2 48.0 45.9 38.4 64-QAM 3/4 53.6 51.5 49.2 47.1 44.8 43.0 41.2 34.3 64-QAM 2/3 47.6 45.6 43.9 41.6 40.1 38.5 36.4 30.3 16-QAM 3/4 35.7 34.1 32.6 31.3 30.0 28.6 27.4 22.3 16-QAM 1/2 23.7 22.6 21.7 20.4 20.0 19.0 17.9 14.2 QPSK 3/4 17.7 16.7 16.0 14.9 14.8 14.1 13.1 10.2 Confidential - Restricted Use and Duplication Page 22 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 7 Element and Network Management Designed to provide comprehensive Fault, Configuration, Accounting, Performance, and Security (FCAPS) functionality, the X-100 system uses standard networking protocols and tools that facilitate a full range of element and network management operations—from local craft configuration, to complex integration in Simple Network Management Protocol (SNMP) or script-based Network Management System (NMS) and Operations Support System (OSS) infrastructures. The X-100 system supports the following network management Interfaces: • X-100 Command Line Interface (CLI). Accessible via Secure Shell protocol (SSH), the X-100 CLI provides a well-structured command language in an industry standard idiom. The interface allows an operator (or third-party system) to manipulate the full configuration of the unit and examine state, performance and fault indicators. • X-100 Web Interface (WebUI). Accessible via HTTP(S), the X-100 WebUI provides an interactive visual toolset that allows an operator to modify the full configuration of the X-100 system as well as view state, fault, and performance indicators. The performance data is displayed using visual charts, and applications are provided to visualize up to 24 hours of historical performance data stored on the system. • Community-Based Simple Network Management Protocol version 2 (SNMPv2C) and SNMP version 3 (SNMPv3). The SNMPv2C and SNMPv3 interfaces provides complete access to configuration, state, performance and fault information in the X-100 system to allow for high levels of integration in existing NMS/OSS infrastructure for monitoring, Service Level Agreement (SLA) assurance, and administrative task automation. • Syslog. The syslog interface allows the X-100 system to send standard syslog fault management information (that is, syslog alarms, events, and log entries) from itself to external syslog servers. All network management interfaces on the X-100 system are accessible via Transmission Control Protocol/Internet Protocol (TCP/IP) and User Datagram Protocol/IP (UDP/IP). The X-100 system provides the following IP addresses for management purposes: • Local Craft IP Address - A fixed, non-routable IP address: 169.254.1.1 which is always accessible without VLAN encapsulation. This address is always present on both the Hub Modules and Remote Backhaul Modules (RBMs) and should be used in situations where the Management IP Address (see below) is not configured or is unavailable, including initial commissioning and field troubleshooting scenarios. Typically, the Local Craft IP Address is accessed by an operator by plugging in directly in the RJ-45 Ethernet port of the module. Note: The RJ-45 port has priority over the optional optical connector on the HM. If the latter is installed and the operator plugs into the RJ-45 port, the fiber connection is disabled as long as the RJ-45 port is active. • Management IP Address - An operator assigned, static or Dynamic Host Configuration Protocol (DHCP) IP address used for remote management of the units. Both HMs and RBMs need a management IP address. For the HM the management IP Address is accessible from the Ethernet side of the network, while for the RBM the management IP Address is accessible from the wireless side (that is, from behind the HM). All traffic to and from the management IP address can be encapsulated in an operator-configurable Virtual Local Area Network (VLAN). Confidential - Restricted Use and Duplication Page 23 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 The X-100 system provides the following network management functions: • Configuration Management. The system configuration covers several functional areas: o radio link commissioning o service flow provisioning o bridge configuration o security configuration All parameters in these areas are accessible via all the network management interfaces described previously. o The radio link commissioning parameters (for example, radio frequency, synchronization, radio frame size, TDD downlink/uplink ratio, preamble indexes) need to be set before system deployment and are particular to the RF network of the operator. o Service Flow Provisioning parameters are set on the HM to configure the quality parameters for the over-the-air service flows provided to RBMs. The system supports both a simple provisioning model based on a default service flow configuration, or an advanced provisioning model where service flow parameters can be configured individually for each RBM. o The bridge configuration parameters control the Ethernet bridge and core network data behavior of the X-100 cluster. o The security configuration parameters allow the operator to secure access or disable specific management interfaces and perform various unit administrative operations. • Fault Management. The X-100 system provides fault management service via a comprehensive list of alarms and events. Some of the potential faults that the system is able to detect and alarm upon include: o radio and Ethernet link failures o hardware module failures o synchronization faults o software module faults All alarms and events are relayed to higher level managers via SNMP traps or Syslog. The system also allows operators to access active alarm and event history information using either the X100 CLI or X-100 WebUI. • Performance Management. The X-100 system maintains a comprehensive set of performance counters and indicators to facilitate: o performance monitoring o SLA monitoring o Troubleshooting The system provides a full set of Ethernet counters at the interface, module, and service flow level, as well as radio quality indicators at the module level. The system makes all the counters available as either instantaneous values (via SNMP, CLI or WebUI), or historical performance files. The system maintains 24 hours of performance data at a 15 minute granularity. Performance files are stored only on the HM and can be extracted from the system on-demand. Alternatively, the system can be configured to automatically push these files to an operator- Confidential - Restricted Use and Duplication Page 24 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 provided File Transfer Protocol (FTP) server. • Administrative Operations. The X-100 system provides tools that allow operators to perform all standard unit administration operations using the provided remote network management interfaces. The system supports remote software upgrade operations using either a pull paradigm (that is, the system modules retrieve the software package files from external FTP servers), or a push scheme using the X-100 WebUI (that is, the operator uploads a software package file to the system modules using the X-100 WebUI). The X-100 system also supports remote configuration backups and backup restoration. Confidential - Restricted Use and Duplication Page 25 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 8 Ethernet Bridge Support Designed to seamlessly integrate into existing Ethernet backhaul or general purpose networks, the X100 system is built for Ethernet services and provides network functionality as a standard Layer 2 (L2) Transparent Bridge (IEEE 802.1d), whereby the X-100 cluster (a cluster being one Hub Module [HM] with its group of up to four Remove Backhaul Modules [RBMs]) is the bridge, and the Ethernet ports on the HM and associated RBMs are the ports of the bridge. The embedded bridge functionality performs Media Access Control (MAC) address learning (up to 4096 MAC addresses). This function allows the HM to perform an optimal allocation of radio resources by sending traffic to the RBM behind which the destination of that traffic is actually located. In addition, the X-100 system provides support for advanced traffic classification and prioritization as part of its service provisioning model. Service flow definitions can be used to engineer traffic so that specific packets are either dropped or forwarded under a specific Quality of Service (QoS) provision. The X-100 scheduler supports two Classes of Service (CoS): Guaranteed Bit Rate (GBR) and Best Effort (BE). The GBR CoS is designed for latency sensitive traffic (such as voice) and provides an “always on” channel that is able to transport designated packets as soon as they arrive in the system. The BE CoS provides a balanced resource allocation between multiple RBMs in a cluster and ensures radio resource fairness between them. The X-100 scheduler contains proprietary optimizations such as CoS overflow/underflow that allow for an optimal utilization of radio resources in situations where certain service flows are either under or over loaded beyond their designed capacity. The X-100 classification engine allows the operator to define complex classification rules using basic boolean constructs and packet field matching criteria. The following fields are supported: • Layer 2 Ethernet frame fields: source/destination MAC Address with masking options, EtherType, VLAN (802.1q), S-VLAN, C-VLAN (as per 802.1ad QinQ) • Layer 3 IP packet fields: source/destination IP address with masking option, Type of Service (ToS). The X-100 system can also provide specialized processing of data traffic at the HM Ethernet port (towards the core network). The operator can choose to either pass traffic transparently or, alternatively, encapsulate the data traffic in an L2 tunnel through a Virtual Local Area Network (VLAN) by using the stacking VLAN processing scheme. The system also allows network management traffic to be encapsulated in a dedicated management VLAN. The X-100 system can transport standard Ethernet frames (up to 1518 bytes) as well as mini Jumbo frames of up to 2048 bytes. Confidential - Restricted Use and Duplication Page 26 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 9 Installation Planning For full installation instructions see the X-100 System Installation Guide. Adhere to all safety warnings in the Installation Guide. Failure to do so could result in personal injury or death, or damage to the equipment. WARNING! When planning the installation of X-100 systems, consider the following: • Delegate installation and repairs to an experienced installer • Determine if lightning protection is needed and install if required Be sure to do the following upon unpacking the X-100 system modules. For each Hub and RBM module in your system: • Locate the label on the module casing that lists the Serial Number (SN) and Media Access Control (MAC) address for the module • Record the SN on your registration card for future reference • Record the MAC address for future reference when provisioning the system Figure 7 Module Casing Label Example After installation of the X-100 system modules, perform the tasks described in Chapter 13 “System Provisioning”, and Chapter 14 “Preambles, Flows, and Network Provisioning”, as applicable for your network. Confidential - Restricted Use and Duplication Page 27 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10 Using the X-100 WebUI 10.1 Requirements The X-100 WebUI is the configuration tool for use with X-100 Hub Modules (HMs) and Remote Backhaul Modules (RBMs). It is a standard web application that runs directly on the X-100 equipment through the default port for HTTP (80), and is accessible at URL http:// . Browser support for X-100 WebUI: • Mozilla Firefox (Fx) • Internet Explorer (IE9) • Safari Operating System (OS) support for X-100 WebUI: • Windows • Mac OS X • Unix • Linux Note: With the exception of IE9, both web browser and OS support for the X-100 WebUI always refer to the most recent versions (for example: Fx17 running on Windows 7). All required X-100 system configuration tasks can be performed using the X-100 WebUI. As an alternative, you can use the X-100 Command Line Interface (CLI) for system monitoring and configuration tasks. See Chapter 12 for details. Confidential - Restricted Use and Duplication Page 28 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.2 Common X-100 WebUI Page Items Most X-100 WebUI pages have either an Apply button or a Refresh button or both at the bottom right hand corner. If you change the settings on a page, ensure to click on Apply before navigating to another page. Readonly data on a page can be updated to their current values at any time by clicking on the Refresh button. The Hub Module or RBM can be rebooted at any time by clicking on the Reboot button at the top of every page. Any change in configuration can be saved by clicking on the Save Config button. This new configuration change will then be loaded upon a system reset. The Save Config button remains grayed out until changes are applied via the Apply button. End each session by clicking on Logout on the right. Several pages present graphs of various parameters. By default these have a two minute rolling x-axis. To zoom in on part of this time, hold the Left Mouse Button down and move the mouse to enclose the amount of time desired. To reset the default x-axis, click on the Reset Zoom button. Confidential - Restricted Use and Duplication Page 29 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.3 Configuring Hub Modules Confidential - Restricted Use and Duplication Page 30 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.3.1 Logging In To log in and access the X-100 WebUI interface for configuring Hub Modules (HMs), do the following: 1. Launch your web browser and set it to allow pop ups (as some screen functions in the X-100 WebUI require pop ups). For Firefox: Click on Tools > Options > Content and uncheck Block pop-up windows. Alternatively, click on the Exceptions button and enter a list of Hub IP addresses you will be configuring. 2. If there is a direct connection to the HM (that is, not over a network), use your browser to go to http://169.254.1.1. 3. If connecting over a network to the HM (that is, not locally), use your browser to connect to the management IP address of the Hub. 4. Log on to the system. The default username and password are admin: User Name: admin Password: admin Note: • User names and passwords are administered through the X-100 WebUI Admin Page using the User Manager sub-page and can be changed anytime (see section 10.3.14 for details). • User names must start with a letter and may be composed of alphanumeric characters only. • Passwords are case sensitive, may be composed of alphanumeric characters and special characters, and must contain at least one letter and one digit. • At least one user with read/write privileges needs to exist in the X-100 system. • If you cannot login due to a forgotten user name or password, contact another user with read/write access privileges to have them reset your login credentials. If you have lost all read/write login credentials, contact your supplier. Confidential - Restricted Use and Duplication Page 31 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.3.2 System Overview Page This read-only page gives general system information on the particular Hub you are logged in to. The RBMs associated with this Hub are also listed along with their information. Further, it visualizes the incoming and outgoing traffic for the RBM and Ethernet connections using two graph lines. This allows the user to see traffic and bandwidth usage for the system RBMs and Ethernet interfaces in a real-time, graphical format, and monitor the current download/upload throughput speeds. The System Overview page also lists the current alarm information at the bottom. Note: The blue graph line represents the downlink throughput rate, while the red graph line represents the uplink throughput rate. Screen refresh interval is every 5 seconds. For system statistics based on these graphs, see section 10.3.9 for Performance Page (Ethernet) and section 10.3.10 for Performance Page (RBMS). Confidential - Restricted Use and Duplication Page 32 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.3.3 Setup Page (System) This sub-page handles configuration of system parameters that govern basic Hub Module operation. System Identification: Enter information here as desired to aid system identification. System Name: Name of the module, composed of alphanumeric characters, underscores, and dashes. System Location: Physical location of the module, composed of alphanumeric characters, underscores, and dashes. System Contact: Contact information for the module owner, composed of alphanumeric characters, underscores, and dashes. Can also include @ for an email address. System Description: Description of the module, composed of alphanumeric characters, underscores, and dashes. Ethernet Port Configuration: Operational State: (Up/Down) (Read only) Operational Speed/Duplex: e.g. 100M Full Duplex (Read only) Auto-Negotiation: (On/Off) If auto-negotiation “Off”, set the following (as applicable): Configured Speed: 10M/100M/1000M Configured Duplex: Auto/Full/Half System Time Configuration: GPS Status: System Date/Time: System Time Zone: System Clock Source: Synchronized/Not-Synchronized (Read only) e.g. 2013-01-01T00:12:24 (Read only) Set relative to UTC Always set to GPS (not FreeRun) Confidential - Restricted Use and Duplication Page 33 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Note: The “FreeRun” mode is intended for isolated trial or laboratory testing of the X-100 system only. Networks of X-100 systems depend on proper synchronization through either GPS or IEEE 1588v21 clock references to operate optimally, and may experience significant performance degradation or even outage if not deployed accordingly. The following system services are also affected in “FreeRun” mode: system time; reporting of time as part of the fault management function; historical performance functions. Management Interface: Current IP Address: Mgmt IP Address: If “Static” set the following: Gateway: IP Address: Netmask: Mgmt VLAN: xxx.xxx.xxx.xxx (Read only) DHCP/Static, set as desired If this is to be used, set check box and enter gateway IP address Set to Hub IP address (if not so already) Set to subnet mask address Enable/Disable (if set to Enable enter ID) 10.3.4 Setup Page (Radio Interface) This sub-page handles configuration of the radio operation for the Hub Module. Radio Settings: Operational Status: Radio Administrative State: Radio Interface Type: RF Frequency: Channel Bandwidth: Max. Transmit Power: Frame Duration: Operational/Down (Read only) Enabled/Disabled 3.5 (Read Only) Set as appropriate 10 MHz (Read Only) Enter between -18 dBm to 23 dBm for the 3.65 – 3.7 GHz non-exclusive licensed band. Enter higher values for large Hub/RBM distances, and lower values for smaller distances so that receiver does not saturate. 3.1251 or 5 ms Not supported in current release. TDD DL/UL Ratio: Preamble Index: Set uplink to downlink bandwidth ratio to 50:50 or 65:35, as desired Enter preamble index value 0 to 31 (factory default is 0); refer to Confidential - Restricted Use and Duplication Page 34 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Chapter 14 for more information on use of preamble indices Rate Adaptation: Minimum and Maximum Uplink and Downlink Modulation and Coding Scheme (MCS) For each, set to one of the following (as applicable): • QPSK3/4 • 16QAM 1/2 • 64QAM 1/2 • 64QAM 2/3 • 64QAM 3/4 • 256QAM 5/8 • 256QAM 6/8 10.3.5 Bridge Page This page handles configuration of standard Layer 2 Ethernet bridging for the Hub Module. Bridge Setttings Bridge Mode: Broadcast Filter: ARP Proxy: Discard DL Unknown ARP: LAN (Read only) Enable/Disable Enable/Disable Enable/Disable L2 Core Network Settings VLAN Handling Mode: None/Stacking (if set to Stacking enter ID) (if set to Stacking enter ID) S-VLAN ID Dynamic Address Table Settings Specifies and saves in the running configuration the amount of time that elapses before an entry in the Confidential - Restricted Use and Duplication Page 35 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Layer 2 MAC dynamic address table is discarded. Note: If you specify 0 (the default), MAC aging is disabled. Aging Time (sec): Set as desired. Allowable entries: 0 to 65535 seconds (default is 0). 10.3.6 RBMs Page (RBM General) The X-100 system is a connection-oriented wireless technology. As such, an RBM cannot transmit data until it has been allocated a channel from its associated Hub Module (HM). This is to provide strong support for Quality of Service (QoS). Each connection between an RBM and its associated Hub in the X100 system is supported by two or more service flows (at least one in the downlink direction and one in the uplink direction). The default for each RBM connection in the X-100 system is one flow in the downlink direction and one in the uplink direction. Each HM can support up to 16 service flows in the downlink and uplink direction, respectively, for a total of 32 service flows, while up to four service flows can be configured per RBM in the downlink and uplink direction, respectively, for a total of eight service flows. The RBM and Hub use a service flow with an appropriate QoS class (plus other parameters, such as priority and classifiers) to ensure that application data receives the QoS treatment appropriate to the user application. The QoS is supported by allocating each service flow a specific QoS class, of which there are two in the X-100 system: Guaranteed Bit Rate (GBR), and Best Effort (BE). The GBR class is for data streams for which the most stringent service scheduling is required, with guarantees on throughput, latency, and jitter. The BE class is for data streams for which no minimum service level is required and therefore may be handled on a space-available, no guarantee basis. Classifiers further define the scope of service flows. On startup the X-100 system automatically finds all the RBMs connected to it. Through this sub-page you can make the HM either: • apply the default service flow definition to all RBMs, as set through the ‘RBMs (Default Service)’ sub-page, by clicking Use Default Service Definition from the list box, or • apply individual service flow definitions to these RBMs on an RBM-by-RBM basis, as set through the ‘RBMs (RBM List)’ sub-page, by clicking Use Individual Service Definition from the list box Note: You can only use one RBM provisioning model at a time. Click Apply for the chosen RBM provisioning model to take effect. Confidential - Restricted Use and Duplication Page 36 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.3.7 RBMs Page (Default Service) On this sub-page you can edit the RBM configuration data for the default service flow definition. Click Apply for the changes to take effect. Confidential - Restricted Use and Duplication Page 37 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Service Flow Select a Service Flow from the list at the left. Details appear on the right where they can be edited. To delete a Service Flow, click on a check box on the list at the left and click on the Remove Selected button. Add a Service Flow by clicking on the Add button. Up to four service flows can be configured per RBM in the downlink and uplink direction, respectively. Editing a Service Flow Priority: If more than one service flow is defined for an up or down link, set priority (0 is highest, 7 is lowest) Direction: Downlink/Uplink QoS Type: Best Effort/Guaranteed Bit Rate If “Guaranteed Bit Rate” set: Max Sustained Rate (kbps) Classifiers for a Service Flow Classifiers further define the scope of service flows. Modify an existing Classifier by clicking on it. The Classifier becomes blue. Set the parameters below it as appropriate. Each check box that is clicked adds an additional requirement for transmission to occur for that Classifier, that is, Boolean AND logic is in effect on each Classifier in a service flow. Changes are detailed on both the left and right of the window. Add a new Classifier by clicking on Add. A new Classifier appears in blue. Set the parameters below it as Confidential - Restricted Use and Duplication Page 38 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 appropriate. Up to eight Classifiers can be configured per service flow, with Boolean OR logic in effect on multiple Classifiers in a service flow. Change the order and priority of Boolean OR operations for multiple Classifiers by drag and drop. The higher up the order the Classifier is, the higher its priority within Boolean OR operations. To delete a Classifier, click on the trash can icon next to it. Layer 2 Classifier parameters include: • Source MAC Address/Mask • Destination MAC address/Mask Layer 3 Classifier parameters include: • Source IP Address • Destination IP Address 10.3.8 RBMs Page (RBM List) On this sub-page you can review RBM information on an RBM-by-RBM basis, as well as add or delete RBMs from the Hub. You can also edit RBM configuration data for individual service flow definitions on an RBM-by-RBM basis. The RBMs are referred to by their MAC address. Sort the list on the left by ascending or descending MAC address, or by state by clicking on the column header. Select: Click Add to add an RBM. In the dialog box that appears enter its MAC address. If desired, copy a service flow definition from an existing RBM by entering its MAC address, or start from a blank one. Click OK. Then edit the RBM. Delete an RBM: On the left, activate check box(es) of desired RBMs and click on Delete Selected. Edit service flow definition: Click on edit to the right of the RBM MAC address. The sub-page that appears is the same one as for the default service flow definition, except that now it applies to this specific RBM only. Refer to section 9.3.7 for details. Add an RBM: Confidential - Restricted Use and Duplication Page 39 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.3.9 Performance Page (Ethernet) This read-only sub-page for Hub Ethernet performance visualizes the incoming and outgoing traffic for the Ethernet interface connections using two graph lines. This allows the user to see traffic and bandwidth usage for the Ethernet interfaces in a real-time, graphical format, and monitor the current download/upload throughput speeds. It also lists the current throughput performance statistics for the Ethernet interfaces. Note: The blue graph line represents the receive throughput rate, while the red graph line represents the transmit throughput rate. Screen refresh interval is every 5 seconds. 10.3.10 Performance Page (RBMs) This read-only sub-page for RBM performance contains graphs and statistics for the downlink/uplink Carrier to Interference-plus-Noise (CINR), downlink/uplink MCS, and downlink/uplink throughput. It visualizes the incoming and outgoing traffic for the system RBMs using graph lines. This allows the user to see traffic and bandwidth usage for RBMs in a real-time, graphical format, and monitor the current download/upload throughput speeds. Note: Screen refresh interval is every 5 seconds. Confidential - Restricted Use and Duplication Page 40 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Click on an RBM on the list at the bottom to view the statistics on signal quality and throughput (per service flow) performance for that RBM. Confidential - Restricted Use and Duplication Page 41 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.3.11 Events Page (Alarms) This read-only sub-page lists current alarms and events along with their details. For a list of alarms and events see Chapter 10. Reorder the alarms and events as desired by clicking on any of the column headers. Confidential - Restricted Use and Duplication Page 42 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.3.12 Events Page (History) This read-only sub-page lists a chronological history of alarms and events along with their details. For a list of alarms and events see Chapter 10. Reorder the alarms and events as desired by clicking on any of the column headers. Note: Clicking Clear Table completely clears the current alarms and events history from the X-100 event logging infrastructure. The only way to retrieve this history afterward is from Syslog (if provisioned). 10.3.13 Admin Page (Management Interface) On this sub-page the administrator can select the types of management interfaces to use (CLI, Web, SNMP) using the radio buttons. One, two or all three can be selected. Note: If you disable the Web option, the X-100 WebUI becomes unusable. You will have to enable it again using either the X-100 CLI or SNMP. It is not possible, however, to lock yourself out of all three options; at least one option is always be available. Confidential - Restricted Use and Duplication Page 43 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.3.14 Admin Page (User Manager) On this sub-page, by clicking on edit at the right of the list the administrator can add and delete users, set passwords, and set access privileges (that is, read-only versus read/write) to manage user access to the Hub. Note: • User names must start with a letter and may be composed of alphanumeric characters only. • Passwords are case sensitive, may be composed of alphanumeric characters and special characters, and must contain at least one letter and one digit. • At least one user with read/write privileges needs to exist in the X-100 system. • If you cannot login due to a forgotten user name or password, contact another user with read/write access privileges to have them reset your login credentials. If you have lost all read/write login credentials, contact your supplier. Confidential - Restricted Use and Duplication Page 44 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.3.15 Admin Page (SNMP Settings) On this sub-page the administrator can add, delete, or edit SNMPv2C or SNMPv3 users and hosts if desired. Confidential - Restricted Use and Duplication Page 45 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.3.16 Admin Page (Software Upgrade) On this sub-page the administrator can perform system software upgrade activities. As shown, active and standby software image versions can coexist simultaneously on the HM (and RBM). Software upgrades can occur either from an FTP server, SFTP server, or from your hard disk. To upgrade the software, do the following: 1. Select either ‘FTP Server’or ‘SFTP Server’ and enter the details, or select ‘Upload File’ and browse for the file on your hard disk. 2. Click on Upgrade at the bottom right hand corner of the page. A progress bar appears at the bottom of the page. 3. If the software download succeeds, the banner at the top of the page indicates this. The ‘Standby Software Version’ field then shows the new software load image version. 4. To make the standby software load image the active image on the module, click on Reboot/Switch at the bottom of the page. Then click on Yes at the prompt. The system restarts using the new software image. If the banner at the top indicates that this was successful you have finished this software upgrade procedure. Confidential - Restricted Use and Duplication Page 46 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 5. If the software upgrade fails (due normally to a corrupt load), the system restarts again using the old software image. The banner at the top of the page indicates that this has happened. In this case, select a different version of the new software and repeat this procedure from Step 1. 10.3.17 Admin Page (Configuration Management) On this sub-page the administrator can save the current configuration to a file on their hard disk. Configuration files can then later be uploaded to restore previous settings. Confidential - Restricted Use and Duplication Page 47 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.3.18 Admin Page (Syslog Server) On this sub-page the administrator can add and delete Syslog Servers, and set or change their operational status. Click on Add to add a new Syslog server to the list displayed. In the dialog box that appears use the radio buttons to toggle its status: ‘Enable’ or ‘Disable’. Its status can be changed later by clicking on edit at the right of the list and using the radio buttons again. Delete a server by checking the box next to it and clicking on Delete Selected. Confidential - Restricted Use and Duplication Page 48 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.4 Configuring RBMs The X-100 WebUI interface for configuring RBMs is similar to that for Hubs. This section focusses on differences only. Moreover, sections that are read-only are not discussed; some of these omit data not appropriate to RBMs and add other data not shown on the X-100 WebUI pages for Hubs. Note: For all RBM X-100 WebUI configuration items not discussed here, see the corresponding Hub item in section 9.3 for details. Confidential - Restricted Use and Duplication Page 49 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.4.1 Logging In To log in and access the X-100 WebUI interface for configuring RBMs, do the following: 1. Launch your web browser and set it to allow pop ups (as some screen functions in the X-100 WebUI require pop ups). For Firefox: Click on Tools > Options > Content and uncheck Block pop-up windows. Alternatively, click on the Exceptions button and enter a list of Hub IP addresses you will be configuring. 2. If there is a direct connection to the RBM (that is, not over a network), use your browser to go to http://169.254.1.1. 3. If connecting over a network to the RBM (that is, not locally), use your browser to connect to the management IP address of the RBM. Note, however, that the management IP address of the RBM is only accessible from behind the HM. Note: To successfully log in and access the X-100 WebUI on an RBM over a network, its HM must be connected to the network, and the radio link from the Hub to the RBM must be up. This is because network communication with an RBM occurs through its associated Hub over the radio link. For more information, refer to section 10.3.1. 10.4.2 System Overview Page This read-only page gives information on the particular RBM you are logged in to as well as current alarm information. Confidential - Restricted Use and Duplication Page 50 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.4.3 Setup Page (System) This sub-page handles configuration of system parameters that govern basic RBM operation and is the same sub-page as for Hub, except: System Clock Source: Mgmt VLAN: Cannot be set from the RBM Cannot be set from the RBM For more information, refer to section 10.3.3 for the corresponding Hub page. 10.4.4 Setup Page (Radio Interface) This sub-page handles configuration of the radio operation of the RBM and is the same sub-page as for Hub, except: Preamble Series: Check ‘All’ or enter preamble index value 0 to 31 (factory default is ‘All’); refer to Chapter 14 for more information on use of preamble indices Pointing Mode (BSI): Enabled/Disabled Pointing Mode or Best Signal Indicator (BSI) is an RBM operating mode which allows the installer to easily determine the direction of the best quality signal from the best serving HM. While in BSI mode, the RBM makes a buzzing noise to reflect the quality/strength of the RF signal it receives from the HM. The higher the quality of RF signal is from the HM, the louder and higher the frequency of the buzzer from the RBM. The installer moves the RBM on its axis and locks it down to its mount when the loudest and highest frequency buzzer noise is heard—indicating the best signal from the best serving HM has been found. The radio link can then be created by inserting an Ethernet cable into the Ethernet port on the RBM. This allows the RBM to lock on to the signal and exit BSI mode. Note: While the RBM is in BSI mode it cannot create a radio link. When initially configuring the RBM prior to being installed, set ‘Pointing Mode (BSI)’ to Enabled so that when the RBM restarts next with no Ethernet cable attached, it enters BSI mode and the installer can then find the optimum position for the RBM on its mount based on the signal quality from the HM. Once the installer plugs the Ethernet cable into the Ethernet port on the RBM to create the radio link to the Hub, the RBM exits BSI mode, and ‘Pointing Mode (BSI)’ can be set to Disabled. This prevents the RBM from entering BSI mode again while up on its mount due to, for example, the base station losing power and in turn not seeing the Ethernet connection to the RBM, causing the RBM to enter BSI mode again. For more information, refer to section 10.3.4 for the corresponding Hub page. Confidential - Restricted Use and Duplication Page 51 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10.4.5 Performance Page This read-only sub-page for RBM performance contains graphs and statistics for the downlink/uplink Carrier to Interference-plus-Noise (CINR), downlink/uplink MCS, and downlink/uplink throughput. It visualizes the incoming and outgoing traffic for the RBM using graph lines. This allows the user to see traffic and bandwidth usage for the RBM in a real-time, graphical format, and monitor the current download/upload throughput speeds. Note: Graph update interval is every 5 seconds. 10.4.6 Events Page Same page and sub-pages as for Hub. Refer to sections 10.3.11 and 10.3.12 for details. 10.4.7 Admin Page Same page and sub-pages as for Hub. Refer to sections 10.3.13 through Error! Reference source not found. for details. Confidential - Restricted Use and Duplication Page 52 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 11 Alarms and Events (Fault Management) This chapter lists the alarms and events for the BLiNQ X-100 system. The X-100 system issues an alarm notification when a fault condition occurs. Alarms issued are presented to users through the X-100 WebUI Events page and require operation and maintenance actions to restore functionality, or prevent a more serious situation from developing. The X-100 system issues an event notification when something of importance happens that does not trigger an alarm, but is considered significant enough to be presented to users through the X-100 WebUI Events page. Table 11 lists each alarm (whose name also represents the particular problem), the alarm ID, type, and explanation on the likely cause of the alarm and possible solution (as applicable). Table 12 lists each event (whose name also represents the particular problem), the event ID, type, and explanation on the likely cause of the event. Severity is also defined for each listed alarm and event, to indicate the relative level of urgency for operator action: • Critical - the alarm or event requires immediate corrective action, regardless of the time • Major - the alarm or event requires immediate corrective action, within working hours • Minor - the alarm or event requires corrective action at a suitable time or, at least, continuous close observation • Warning - the alarm or event requires corrective action on a scheduled maintenance basis • Information – the alarm or event requires no corrective action; it is for informational purposes only Table 10 List of Alarms ID Name Description/Comments Type Severity 6004 Radio Card Failure — Equip. One card down (degraded performance): Major; Two cards down (no service): Critical 6005 Hardware Failure — Equip. Critical 6006 Temperature Too High Recovers when the temperature falls below threshold Equip. Critical 4001 Ethernet Port Down Recovers when Ethernet link is reestablished Comms Critical Radio Module Down Two possible causes: a) Radio Driver lost connection with OAM Proxy and cannot reestablish connection. Alarm is followed by the Driver issuing a hardware reset to the Radio Module subsystem. Equip. 5006 Confidential - Restricted Use and Duplication Page 53 of 91 Critical Issue 01 BLiNQ Networks Inc. X-100 User Guide ID Name 5007 RF Port Open The system has detected an open RF port. Recovers when the system detects the port is no longer open. Equip. 5010 Invalid RF Card Calibration Data Recovers when the system detects the port is no longer open Equip. The system has detected a power fault. Recovers when the system detects the power fault is no longer present Equip. Major Comms Major Equip. 5009 Power Detector Fault Description/Comments b) The Radio Driver is expecting the Radio Module to boot (for example, following a soft reset or after unit restart) and the DAN Driver fails to establish connection with the Radio Module after a certain time. Recovers when Radio Driver reestablishes connection with the Radio OAM Proxy. Release 1.0 Type Severity Critical Critical 7001 GPS Synchronization Lost GPS receiver lost its synchronized status. Upon Hub reset, this alarm is not raised until 60 sec after reset and if synchronization still is not achieved. After hold-over time expires (10 minutes), GPS transitions to unsynchronized state. 7002 GPS Synchronization Failed GPS transitioned from hold-over to unsynchronized state. System stops transmitting. All RBM Links Down Hub has lost all RBM connections. Upon Hub reboot, alarm occurs only if no RBM has established connection within 20 secs from the time the Hub radio is operational. Comms If any RBM is configured as “Emit alarm when down”: Critical Otherwise: Major RBM Link Down Hub has lost connection to an RBM that is configured to “Emit alarm when down.” Upon Hub reboot, alarm occurs only if RBM has not established connection within 20 secs from the time the Hub radio is operational. Comms Critical 3004 Software Boot Failure Switchover software versions after a failed boot attempt. Probably a storage capacity problem. Equip. Major 2002 Management Address Lease Renew Failed Cannot renew its DHCP lease when unit is configured to use DHCP for the Management IP Address. Recovers when lease renewed. Equip. Minor 4002 4003 Confidential - Restricted Use and Duplication Page 54 of 91 Critical Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Table 11 List of Events ID Name Description/Comments Type Severity 6001 Cold Start Unplanned restart Equip. Information 6002 Warm Start Planned restart Equip. Information 5001 Radio Module Initialized Radio driver established communication with the OAM Proxy Equip. Information 5002 Radio Module Entering Pointing Mode No transmitting occurs in this mode; it is “receive only” radio operation Equip. Information 5003 Radio Module Entering Operational Mode Normal send/receive operation Equip. Information 5004 Radio Module Disabled Radio Module is initialized and received an administrative disable configuration Equip. Information 5005 Radio Module Initializing Radio Module intentionally reset Equip. Information 7003 GPS Lock Acquired GPS entered synchronized state Equip. Information 3001 Software Download Initiated Software download procedure initiated Equip. Information 3002 Software Download Successful Software download successfully completed Equip. Information 3003 Software Download Failed Either: transfer, file validation or file persistence error Equip. Major 2001 Startup Configuration Changed Changes to the system running configuration have been saved to the startup configuration Equip. Information 8001 Authentication Failed Attempt to authenticate on one of the management interfaces of the equipment failed Process -ing Error Minor Confidential - Restricted Use and Duplication Page 55 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 12 Using the X-100 Command Line Interface The BLiNQ X-100 Command Line Interface (CLI) is a text-based interface to the BLiNQ X-100 system. 12.1 Overview The X-100 CLI provides commands that the network administrator can use to perform various tasks, including configuring, provisioning, monitoring and troubleshooting the module software, hardware, and network connectivity. Using a Secure Shell (SSH) connection, you can access the X-100 CLI over the network. The commands in the X-100 CLI let you display information and perform configuration tasks and make configuration changes to the X-100 system. The CONFIG level contains, for example, sub-levels for Ethernet port setting, management interface settings, and other configuration areas such as global default CLI session parameters. To display a list of the available X-100 CLI commands or command options, enter ?. The X-100 CLI supports command completion, so you do not need to enter the entire name of a command or option. If you enter part of a command, then press Tab or , the CLI lists the options you can enter at that point in the command string. As long as you enter enough characters of the command or option name to avoid ambiguity with other commands or options, the CLI understands what you are typing and completes it. Note: Command comments can be entered directly in the X-100 CLI by identifying them with an exclamation mark (!) at the start of a line. This tells the X-100 system that the information is a comment and is to be ignored. 12.2 Identify Command Context Command levels set a context for the X-100 CLI. Command context helps you: • determine where you are in CONFIG command levels • determine what you are configuring • go to other CLI command levels Each command level has its own distinct CLI command prompt so that you know which level you are in. By recognizing the command line prompt, you can identify where you are in the CLI and the context at any given point. This helps to prevent you from making configuration mistakes that could adversely affect the operation of the X-100 system. The X-100 CLI command prompt changes at each level of the command structure to easily identify the current level: localhost# localhost(config)# Privileged EXEC Level Command Global CONFIG Level Command Confidential - Restricted Use and Duplication Page 56 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 12.3 Logging On to the X-100 CLI Note: The CLI has an inactivity timer which logs out inactive users. This inactivity time is automatically invoked if no commands are entered for several minutes. You cannot change the inactivity timer configuration. Once an IP address is assigned to a module, you can log on to the X-100 CLI using a Secure Shell (SSH) connection (SSH is an application for opening a secure socket connection to an IP device). However, SSH version 2.0 client software must be installed on your host computer (SSH version 1.0 can be used, but is not recommended). After initial log on, once CLI connectivity to the X-100 system is established, you see a CLI banner and prompt similar to: BLiNQ X100 CLI admin connected from 192.168.5.100 using ssh on localhost localhost# At this prompt (#), you are at the Privileged EXEC level of the CLI command structure. This is the first level that you have access to when connected to the X-100 system through the X-100 CLI. To reach the Global CONFIG Level, the uppermost level of the CONFIG commands, enter the config Privileged EXEC command. You can then reach all the other levels of the CONFIG command structure from this point. BLiNQ X100 CLI admin connected from 192.168.5.100 using ssh on localhost localhost# config terminal Entering configuration mode terminal localhost(config)# The CLI is now at the Global CONFIG level. 12.4 Privileged EXEC Commands The Privileged EXEC level commands primarily enable you to review information on the system configuration, monitor features globally on an X-100 system (through show commands), perform and configure basic user operations, transfer and store configuration files, and verify system connectivity. It does not allow you to make changes to the system configuration. localhost# Possible completions: autowizard clear compare complete-on-space config copy display-level Automatically query for mandatory elements Clear parameter Compare running configuration to another configuration or a file Enable/disable completion on space Manipulate software configuration information Copy configuration from one store to another Configure show command display level Confidential - Restricted Use and Duplication Page 57 of 91 Issue 01 BLiNQ Networks Inc. event-history exit file help history id idle-timeout ignore-leading-space job logout no output-file paginate prompt1 prompt2 quit screen-length screen-width send show show-defaults source system terminal who write X-100 User Guide Release 1.0 Exit the management session Perform file operations Provide help information Configure history size Show user id information Configure idle timeout Ignore leading whitespace (true/false) Job operations Logout a user Negate a command or set its defaults Copy output to file or terminal Paginate output from CLI commands Set operational mode prompt Set configure mode prompt Exit the management session Configure screen length Configure screen width Send message to terminal of one or all users Show information about the system Show default values when showing the configuration File to source Set terminal type Display currently logged on users Write configuration 12.5 Global CONFIG Commands The Global CONFIG commands allow you to globally apply or modify configuration parameters for an X100 system: localhost# config terminal Entering configuration mode terminal localhost(config)# Possible completions: admin Administrative settings and commands alias Create command alias. ethernet Ethernet port settings event-history mgmt Management interface settings radio Radio Interface Settings session Global default CLI session parameters system System settings user --abort Abort configuration session clear Remove all configuration changes commit Commit current set of changes copy Copy a dynamic element do Run an operational-mode command end Terminate configuration session exit Exit from current mode help Provide help information insert Insert a parameter Confidential - Restricted Use and Duplication Page 58 of 91 Issue 01 BLiNQ Networks Inc. load move no pwd rename resolved revert rollback save service show top validate X-100 User Guide Release 1.0 Load configuration from an ASCII file Move a parameter Negate a command or set its defaults Display current mode path Rename an identifier Conflicts have been resolved Copy configuration from running Roll back database to last committed version Save configuration to an ASCII file Modify use of network based services Show a parameter Exit to top level and optionally run command Validate current configuration Within the Global CONFIG level you can: • Apply features globally to an X-100 system • Enable/disable a feature or function • Configure a feature or function • Access all other CONFIG level modes (for example, Radio CONFIG, User CONFIG, RBM Config) 12.5.1 Radio CONFIG Mode localhost(config)# radio localhost(config-radio)# Possible completions: admin-state Radio enable/disable bandwidth Bandwidth bsi-admin-state Pointing mode enable/disable frame-duration Frame duration frequency Center frequency preamble Preamble configuration transmit-power Maximum transmit power --commit Commit current set of changes exit Exit from current mode help Provide help information no Negate a command or set its defaults pwd Display current mode path top Exit to top level and optionally run command localhost(config-radio)# 12.5.2 User CONFIG Mode localhost(config)# admin Possible completions: cli Command Line Interface settings snmp SNMP agent settings users CLI and WebUI users localhost(config)# admin users user Possible completions: User name ([A-Za-z_][A-Za-z0-9_-]*) admin localhost(config)# admin users user admin Confidential - Restricted Use and Duplication Page 59 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 localhost(config-user-admin)# Possible completions: group Group the user belongs to password User password --commit Commit current set of changes exit Exit from current mode help Provide help information no Negate a command or set its defaults pwd Display current mode path top Exit to top level and optionally run command localhost(config-user-admin)# localhost(config)# localhost(config)# admin users user roy Value for 'password' ( ): ******** Value for 'group' [read-only,read-write]: read-write localhost(config-user-roy)# ? Possible completions: group Group the user belongs to password User password --commit Commit current set of changes exit Exit from current mode help Provide help information no Negate a command or set its defaults pwd Display current mode path top Exit to top level and optionally run command localhost(config-user-roy)# 12.5.3 RBM CONFIG Mode (Hub Modules Only) HUB_traffic# HUB_traffic# config terminal Entering configuration mode terminal HUB_traffic(config)# ? Possible completions: admin Administrative settings and commands alias Create command alias. bridge L2 Bridge Settings ethernet Ethernet port settings event-history mgmt Management interface settings radio Radio Interface Settings rbm-table RBM Table session Global default CLI session parameters system System settings user --abort Abort configuration session clear Remove all configuration changes commit Commit current set of changes copy Copy a dynamic element do Run an operational-mode command Confidential - Restricted Use and Duplication Page 60 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 end Terminate configuration session exit Exit from current mode help Provide help information insert Insert a parameter load Load configuration from an ASCII file move Move a parameter no Negate a command or set its defaults pwd Display current mode path rename Rename an identifier resolved Conflicts have been resolved revert Copy configuration from running rollback Roll back database to last committed version save Save configuration to an ASCII file service Modify use of network based services show Show a parameter top Exit to top level and optionally run command validate Validate current configuration HUB_traffic(config)# HUB_traffic (config)# rbm-table rbm ? Possible completions: MAC address 0c:a1:38:00:00:4f RBM 3 0c:a1:38:00:00:56 RBM 2 0c:a1:38:00:00:63 RBM 4 0c:a1:38:00:00:81 RBM 1 HUB_traffic(config)# rbm-table rbm 0c:a1:38:00:00:81 HUB_traffic(config-rbm-0c:a1:38:00:00:81)# ? Possible completions: description Description/label service-flows Service flows list vlan-table VLAN table --commit Commit current set of changes exit Exit from current mode help Provide help information no Negate a command or set its defaults pwd Display current mode path top Exit to top level and optionally run command HUB_traffic(config-rbm-0c:a1:38:00:00:81)# service-flows service-flow ? Possible completions: Service flow ID 0 1 range HUB_traffic(config-rbm-0c:a1:38:00:00:81)# service-flows service-flow 1 HUB_traffic(config-service-flow-1)# classification rule 0 HUB_traffic(config-rule-0)# show full rbm-table rbm 0c:a1:38:00:00:81 service-flows service-flow 1 classification rule 0 dst-mac-addr 00:00:00:00:00:00 dst-mac-mask 00:00:00:00:00:00 HUB_traffic(config-rule-0)# ? Possible completions: c-vlan-id Inner (C-VLAN) tag VLAN ID c-vlan-priority Inner (C-VLAN) tag priority bit dst-ip Destination IP address Confidential - Restricted Use and Duplication Page 61 of 91 Issue 01 BLiNQ Networks Inc. dst-mac-addr dst-mac-mask ethertype max-tos min-tos priority protocol s-vlan-id s-vlan-priority src-ip src-mac-addr src-mac-mask --commit exit help no pwd top X-100 User Guide Destination MAC Destination MAC Ethertype Type of Service Type of Service Rule priority Release 1.0 address address mask (ToS) maximum value (ToS) minimum value Outer (S-VLAN) tag VLAN ID Outer (S-VLAN) tag priority bit Source IP address Source MAC address Source MAC address mask Commit current set of changes Exit from current mode Provide help information Negate a command or set its defaults Display current mode path Exit to top level and optionally run command 12.6 X-100 CLI Command Structure To get a quick display of available options at a CLI level or for the next option in a command string, enter a single question mark ? at the prompt, press Tab, or press . When an item is bracketed with < > symbols, the information requested is a variable and required. When an item is enclosed with [ ] symbols, it shows the current value of the variable. When an item is not enclosed by < > or [ ] symbols, the item is a required keyword. When two or more options are separated by a / symbol, you must enter one of the options as part of the command. Example 1: localhost(config)# mgmt Possible completions: default-gateway interfaces Management interfaces administrative state ip Management IP address and netmask ip-config-mode Management IP mode syslog Syslog server settings localhost(config)# mgmt ip-config-mode Possible completions: dhcp static Example 2: localhost# terminal ? Possible completions: localhost# terminal Confidential - Restricted Use and Duplication Page 62 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Example 3: To view possible show command offerings, enter the following: localhost# show ? Possible completions: active-alarms Active alarms list cli Display cli settings configuration ethernet Ethernet port settings event-history history Display CLI command history mgmt Management interface settings pm Performance measurements radio Radio Interface Settings running-config Display current configuration startup-config Display startup configuration system System settings localhost# show 12.7 X-100 CLI Command Line Prompts Within the X-100 CLI, the command line prompt identifies both the hostname and the command mode. The hostname is the name of your X-100 system; the command mode indicates your location within the CLI command structure. For example: Confidential - Restricted Use and Duplication Page 63 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 For some actions, the X-100 CLI prompts you for a response. The acceptable default responses are the following: • You can press to agree with the prompt and continue. • You can press any other key to disagree with the prompt and cancel the action. 12.8 X-100 CLI Keywords and Parameters X-100 CLI commands are made up of two primary elements: keywords and parameters. 12.8.1 Keywords Every command requires at least one keyword; however, a command can contain other optional keywords. The keyword(s) must be typed into the CLI accurately for it to be recognized. These are examples of keywords: • clear • config • exit • load • revert • show Keywords identify the operation to be performed. You can abbreviate keywords; however, you must enter enough initial characters to unambiguously identify the command. For example, if the keyword you want to specify is session and you enter only s, a list of possible completions appears. This list indicates that one or more possible keywords begin with s, thus making your entry ambiguous. localhost(config)# s Possible completions: session Global default CLI session parameters system System settings --save Save configuration to an ASCII file service Modify use of network based services show Show a parameter 12.8.2 Parameters Parameters are often required elements of a command; however, for some commands, parameters are not required. A parameter is most often a value that you specify after the keyword. There are different types of parameters, such as strings, integers, or IP addresses. The X-100 CLI indicates the type of parameter that you must enter. When you see a range of numbers or uppercase letters, it indicates that you must specify a value. Confidential - Restricted Use and Duplication Page 64 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 12.8.3 Keywords and Parameters Together By combining keywords and parameters in the correct sequence, you can begin using the X-100 CLI to configure and monitor your X-100 system. For example, you could specify the Global CONFIG command user service to add a description of the user service to the X-100 system by entering a keyword and a parameter. You need to type only the portion of the keyword that makes it unambiguous, such as des. Here, the value of the parameter, which is the description you assign to the user service (for example, “Web Access 1”), is a string of up to 64 characters. For example: localhost(config)# user service localhost(config-user-service)# ? Possible completions: alias Create command alias. description User description session User specific default CLI session parameters --commit Commit current set of changes exit Exit from current mode help Provide help information no Negate a command or set its defaults pwd Display current mode path top Exit to top level and optionally run command localhost(config-user-service)# des ( ): 12.9 Saving Configuration Changes Made Through the X-100 CLI When using the X-100 CLI to change parameters on the X-100 system configuration, the changes do not take effect immediately. This example shows the full process to follow to have system configuration changes made through the X-100 CLI take effect on the X-100 system and have them saved across system restarts. Confidential - Restricted Use and Duplication Page 65 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 For example, to change the radio frequency on the X-100 system, you run the radio Global CONFIG command: localhost# localhost# config terminal localhost(config)# radio localhost(config-radio)# frequency 2310000 localhost(config-radio)# While you have entered a new value for the radio frequency to be 2310000, this configuration change has not taken effect (if you were to measure the frequency it would still be at the original value). For this change to take effect, you need to run the commit Global CONFIG command: localhost(config-radio)# commit #commit complete localhost(config-radio)# Now your change has taken effect and the radio frequency is actually operating at the 2310000 frequency on the X-100 system. However, this has only made a change to the current running configuration of the X-100 system—not the startup configuration (the startup configuration is loaded upon booting the system). This means that if the system is restarted, the running configuration changes are lost unless they have been previously saved to the startup configuration. To do this, copy the running configuration to the startup configuration on the X-100 system by using the copy Privileged EXEC command: localhost(config-radio)# exit localhost(config)# exit localhost# copy running-configuration startup-configuration localhost# Through the X-100 CLI, by way of this example you have now successfully made a change to the X-100 system configuration, committed this change to the running configuration, and copied the running configuration to the startup configuration, thereby saving the configuration change across system restarts. Confidential - Restricted Use and Duplication Page 66 of 91 Issue 01 BLiNQ Networks Inc. 12.10 X-100 User Guide Release 1.0 Writing and Running X-100 CLI Scripts To simplify the loading of common or repetitive configuration setups, the X-100 CLI has a basic scripting facility that enables you to define and run scripts that run multiple CLI commands in series to completion. Depending on your needs, you might want to store all of your CLI commands in one script file, or group script files by function. To run a basic CLI script file on the X-100 system, save the script as text, then copy and paste it directly into the X-100 CLI at the Global CONFIG level. The script then runs on the X-100 system. Ordinarily, when a CLI script is run, it is run to completion, even if errors are encountered. Always observe these key points when writing or running CLI scripts: • The commands in the script must be valid in the current operating mode. • If a command inside a script contains a syntax error, or fails for some other reason, the remainder of the commands in the file are still run (that is, script execution does not abort on failure). • A script does not require an exit or logout command at the end. If present, these commands are run normally, such that if run in user mode the CLI session is exited. • Comments can be included directly in the CLI script file itself and are identified with an exclamation mark (!) at the start of a line. This tells X-100 modules that the information is a comment and should not be displayed or parsed. Comments do not require an end tag. Note: If you decide to include comments, anyone who reads or edits your CLI script may read them. Any application that parses or validates your CLI script ignores commented information. 12.11 Using Help The X-100 CLI provides a variety of useful context-sensitive help features. An important thing to remember about using the help features is that the use of a space or the lack of a space before the ? gives different results. Table 13 summarizes the help system. Table 12 Help Commands Command ?, help, partial-command Command ? Confidential - Restricted Use and Duplication Description Lists all commands or command options available in the current CLI level. Completes the partial command you entered, if you have provided an unambiguous abbreviation. Otherwise, if ambiguous, the CLI lists the available command options. Gives detailed help on the specific command and its available parameters in the current CLI level. Page 67 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 12.11.1 ? (Question Mark Key) You can enter the question mark (?) key whenever you need additional information. When you enter ?, all available choices for the CLI level are displayed. When you enter ? on a line by itself or when it is preceded by one or more spaces, a list of all next available choices is displayed. Refer to Example 1. Example 1 From the prompt, you can enter ? to display the online help: BLiNQ X100 CLI admin connected from 192.168.5.100 using ssh on localhost localhost# ? Possible completions: autowizard Automatically query for mandatory elements clear Clear parameter compare Compare running configuration to another configuration or a file complete-on-space Enable/disable completion on space config Manipulate software configuration information copy Copy configuration from one store to another display-level Configure show command display level event-history exit Exit the management session file Perform file operations help Provide help information history Configure history size id Show user id information idle-timeout Configure idle timeout ignore-leading-space Ignore leading whitespace (true/false) job Job operations logout Logout a user no Negate a command or set its defaults output-file Copy output to file or terminal paginate Paginate output from CLI commands prompt1 Set operational mode prompt prompt2 Set configure mode prompt quit Exit the management session screen-length Configure screen length screen-width Configure screen width send Send message to terminal of one or all users show Show information about the system show-defaults Show default values when showing the configuration source File to source system terminal Set terminal type who Display currently logged on users write Write configuration localhost# config terminal Entering configuration mode terminal localhost(config)# ? Possible completions: admin Administrative settings and commands alias Create command alias. Confidential - Restricted Use and Duplication Page 68 of 91 Issue 01 BLiNQ Networks Inc. ethernet event-history mgmt radio session system user --abort clear commit copy do end exit help insert load move no pwd rename resolved revert rollback save service show top validate X-100 User Guide Release 1.0 Ethernet port settings Management interface settings Radio Interface Settings Global default CLI session parameters System settings Abort configuration session Remove all configuration changes Commit current set of changes Copy a dynamic element Run an operational-mode command Terminate configuration session Exit from current mode Provide help information Insert a parameter Load configuration from an ASCII file Move a parameter Negate a command or set its defaults Display current mode path Rename an identifier Conflicts have been resolved Copy configuration from running Roll back database to last committed version Save configuration to an ASCII file Modify use of network based services Show a parameter Exit to top level and optionally run command Validate current configuration Alternatively, the user can terminate a command with a ? to display the complete help on that command. This feature is most powerful when the command keyword is known, but the list and format of parameters is not. Refer to Example 2. Example 2 You can terminate an X-100 CLI command with a ? to display the complete help on that command: localhost(config)# mgmt ? Possible completions: default-gateway interfaces Management interfaces administrative state ip Management IP address and netmask ip-config-mode Management IP mode syslog Syslog server settings 12.11.2 help Command From the prompt, you can enter the help command when you want to display a brief description of the X-100 CLI help system. localhost# help Confidential - Restricted Use and Duplication Page 69 of 91 Issue 01 BLiNQ Networks Inc. Possible completions: autowizard clear compare complete-on-space config copy display-level event-history exit file help history id idle-timeout ignore-leading-space job logout no output-file paginate prompt1 prompt2 quit screen-length screen-width send show show-defaults source system terminal who write X-100 User Guide Release 1.0 Automatically query for mandatory elements Clear parameter Compare running configuration to another configuration or a file Enable/disable completion on space Manipulate software configuration information Copy configuration from one store to another Configure show command display level Exit the management session Perform file operations Provide help information Configure history size Show user id information Configure idle timeout Ignore leading whitespace (true/false) Job operations Logout a user Negate a command or set its defaults Copy output to file or terminal Paginate output from CLI commands Set operational mode prompt Set configure mode prompt Exit the management session Configure screen length Configure screen width Send message to terminal of one or all users Show information about the system Show default values when showing the configuration File to source Set terminal type Display currently logged on users Write configuration 12.11.3 Partial-keyword At any point in the command line, the user can press to display the valid inputs onward. When you cannot recall a complete command name or keyword, type in the first few letters, press , and the system completes your partial entry. However, you must type enough characters to Confidential - Restricted Use and Duplication Page 70 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 provide a unique abbreviation. If your partially entered command is not unique, the CLI presents you with a list of valid options. For example: localhost# show run A subsequent will then display the valid parameters for the command / argument pair: localhost# show running-config Possible completions: admin Administrative settings and commands alias Create command alias. ethernet Ethernet port settings mgmt Management interface settings radio Radio Interface Settings session Global default CLI session parameters system System settings user Output modifiers 12.12 Upgrading System Software Through the X-100 CLI Active and standby software image versions can coexist simultaneously on the HM and RBM. Entering the show system software Privileged EXEC command displays the ‘running-version’, ‘restartversion’, and ‘available-version’ software images currently on the HM or RBM. The running and restart versions represent the currently ‘active’ system software images, while the available version represents the ‘standby’ system software image. For example: localhost# show system software system software running-version 1.0.10_1 system software restart-version 1.0.10_1 system software available-version 1.0.7_1 localhost# To ugrade the software through the X-100 CLI, do the following: 1. Run the systems software download Privileged EXEC command to download a new software image onto the HM or RBM from an FTP server. If the software download is successful, the command output indicates “Upgrade was successful”. For example: Confidential - Restricted Use and Duplication Page 71 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 localhost# system software download ftp blinq1 blinq1 169.254.1.27 BLiNQ_X100_0.13.0_2.bin Downloading BLiNQ_X100_0.13.0_2.bin from 169.254.1.27 using FTP..... ftp succeeded. Verifying the checksum of the image....... Checksums are equal checksum is valid Uncompressing image......... We are running from partition 0 Applying the app directory Applying the os directory Applying the radio directory ./kernel/ ./kernel/vmlinux Kernel is present Putting Kernel in Boot Partition 1 22544628 bytes File stored in partition 1 Upgrade was successful 2. Run the show system software Privileged EXEC command. The ‘available-version’ field (that is, the ‘standby’ system software image) should show the new software load image version: localhost# show system software system software system software localhost# system software running-version 1.0.10_1 restart-version 1.0.10_1 available-version BLiNQ_X100_0.13.0_2.bin 3. To make the ‘available-version’ software (that is, the ‘standby’ software load image) the active software on the module, run the system software switchover Privileged EXEC command: localhost# system software switchover On completion, the HM or RBM resets and the user is forced out of the X-100 CLI. Log in again once the X-100 system is back up and running. 4. If the software upgrade fails (due normally to a corrupt load), the system restarts again using the old software image. The command output from the systems software download command indicates that this has happened. In this case, select a different version of the new software and repeat this procedure from Step 1. Confidential - Restricted Use and Duplication Page 72 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 13 System Provisioning This chapter describes the tasks associated with preparing an X-100 system to allow it to provide network services to its users. Each section in the chapter covers a different task: • Initial System Setup and IP Configurations • Adding Users • Provisioning Default Versus Individual Service Flows • Configuring and Adding Individual RBMs 13.1 Initial System Setup and IP Configurations When you receive a new X-100 system from the factory with no configuration on it, you must connect to the management interface so that you can change the management IP address of the Hub Module (HM) and configure other management parameters for the system, as follows: 1. Connect your computer directly to the HM through an Ethernet cable. Once you have the cable connected to the HM, check your connectivity to the management interface IP address by pinging the HM. There are two IP addresses you can use for this: 192.168.26.2/24, the default IP address given to all X-100 systems from the factory 169.254.1.1/16, the debug IP address that is always accessible as it cannot be changed by the user 2. Ensure that the NIC on your computer has been assigned an address within one of the subnets for these two IP addresses. Note: If you cannot access the 192.168.26.2 address, it is possible that someone has changed this IP. When you are unsure of the IP address of the module, use the 169.254.1.1 address as it cannot be changed. 3. After successfully pinging either of two IP addresses above, either: a. Open a web browser and navigate to the IP address that you pinged to bring up the X100 WebUI. b. Use a Secure Shell (SSH) client to log on to the X-100 CLI using an SSH connection to the IP address that you pinged. However, SSH version 2.0 client software must be installed on your host computer (SSH version 1.0 can be used, but is not recommended). 4. When prompted for login credentials, enter the default username and password admin. Once logged on to the HM, you can change the IP address of the management interface. This can be done by one of two methods. You can choose to either statically assign the IP address for the management interface, or you can use the Dynamic Host Configuration Protocol (DHCP) to configure this IP address. Confidential - Restricted Use and Duplication Page 73 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Note: To have DHCP properly assign an address to your X-100 system, the system must have network access to a DHCP server on your local network. This DHCP server must have available addresses in its address pool, which are in the desired subnet you wish to assign to the system. By default, the X-100 system is configured to get an IP address for the management interface through DHCP. If desired, change it to a static user-assigned IP address using the X-100 WebUI, as follows: 1. Navigate to the “Setup Page (System)” sub-page of the X-100 WebUI. In the bottom right corner, under “Management Interface”, are all the configurable options for the management interface. 2. Change the “Mgmt IP Address” selection from “DCHP” to “Static”. 3. Enter an IP address, netmask, and optionally an address for the default gateway (local router). 4. Click “Apply” in the bottom right corner for the changes to take effect. Alternately, if you wish to use the X-100 CLI to change this management IP to a static user-assigned IP address (for example, 192.168.1.1/24), enter these commands: localhost# localhost# config Entering configuration mode terminal localhost(config)# mgmt ip-config-mode static localhost(config)# mgmt ip 192.168.1.1/24 localhost(config)# commit Commit complete. Confidential - Restricted Use and Duplication Page 74 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 To allow for a radio link to be created between an HM and RBM, you must at a minimum initially configure the following for the X-100 system, as follows: 1. Navigate to the “Setup Page (Radio Interface)” sub-page of the X-100 WebUI. 2. Set the Radio Administrative State to “Enabled”. 3. Ensure both the HM and RBM have their radio frequencies set to matching values that are within the range of usable frequency for the X-100 system. Note: The radio frequency tuning granularity is 1 kHz. 4. Click “Apply” in the bottom right corner for the changes to take effect. General notes: • The following RF parameters must match between an HM and RBM for a radio link to be created: o frequency o preamble index value (for more information on preambles, refer to Chapter 14) • Since the RBM factory default value for the preamble index is “All”, it automatically accepts preambles from any HM. Other preamble index values can be configured provided the HM and RBM preamble index values match. • These RF parameters are passed from the HM to the RBM: o TDD DL/UL ratio o Frame Duration (that is, size) o Max/Min DL MCS o Max/Min UL MCS Confidential - Restricted Use and Duplication Page 75 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 13.2 Adding Users Adding users to the X-100 system can be done through either the X-100 WebUI or the X-100 CLI. To add users to the X-100 system using the X-100 WebUI: 1. Navigate to the “Admin Page (User Manager)” sub-page of the X-100 WebUI. 1. Choose “User Manager” from the tabs on the left side of the page. 2. Click “+Add” to add a user. 3. From the prompt you can now enter a username, password, and choose the access privilege group you wish the user to belong to (either read-only or read/write). Note: o User names must start with a letter and may be composed of alphanumeric characters only. o Passwords are case sensitive, may be composed of alphanumeric characters and special characters, and must contain at least one letter and one digit. o At least one user with read/write privileges needs to exist in the X-100 system. o If you cannot login due to a forgotten user name or password, contact another user with read/write access privileges to have them reset your login credentials. If you have lost all read/write login credentials, contact your supplier. 4. Click “Apply” for the changes to take effect. To add users to the X-100 system using the X-100 CLI, enter these commands: localhost# localhost# config Entering configuration mode terminal Confidential - Restricted Use and Duplication Page 76 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 localhost(config)# admin users user password group localhost(config-user- )# commit Commit complete. This command string creates a user with the given username, password, and access privilege based on the group. 13.3 Provisioning Default Versus Individual Service Flows The HM has two service flow definitions for allowing communication to be established with a RBM, set through the ‘RBMs (RBM General)’ X-100 WebUI sub-page for HMs: • Use Default Service Definition • Use Individual Service Definition If Use Default Service Definition is set, you can define up to four unidirectional default service flow definitions for that HM as set through the ‘RBMs (Default Service)’ sub-page. All RBMs connecting to this HM then are assigned this service flow definition profile and it is not necessary to enter MAC addresses for the RBMs as the HM automatically discovers them. Use of this definition is best associated with the Automatic Scan Mode for RBMs because any RBM can then automatically connect to an HM, and the HM does not need to know the MAC address of the RBM. Note: You cannot use individual service definition profiles on a per RBM basis If Use Default Service Definition is set since all the RBMs then have the same default service flow assigned as defined in the HM. If Use Individual Service Definition is set, you can define and assign up to four downlink and four uplink service flows for each RBM (for a total of 32 per HM) through the ‘RBMs (RBM List)’ sub-page. The assignment is done based on the MAC address of each RBM, so use of this definition requires you to manually provision the HM with the MAC addresses of the RBMs. The RBM preamble operating mode must in turn either be set to Automatic Scan Mode, or its preamble series index value must be set to match that of the HM through the Defined Preamble Mode. In summary, the typical use cases for the HM service flow definitions are: • Use Case 1—If the operator has one service flow definition that applies to all RBMs in the cluster, set the HM service flow definition to Use Default Service Definition. There is then no need to provision the HM with the MAC addresses of the RBMs as the HM automatically discovers the RBM MAC addresses. • Use Case 2—If the operator wants to configure individual service flow definitions for each RBM in the cluster on an RBM-by-RBM basis, set the HM service flow definition to Use Individual Service Definition. This requires you to manually provision the HM with the MAC address for each RBM in its cluster, as described in section 13.4 “Manually Adding and Configuring Individual RBMs”. 13.4 Configuring and Adding Individual RBMs With the HM service flow definition set to Use Individual Service Definition, you must configure each RBM service flow and add the RBMs to the X-100 system on an RBM-by-RBM basis. This can be done through either the X-100 WebUI or the X-100 CLI. Confidential - Restricted Use and Duplication Page 77 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 For example, to configure a default, pass-all, bidirectional service flow on the HM for one RBM on the X-100 system using the X-100 WebUI: 1. Navigate to the RBMs page of the X-100 WebUI. 2. Click Add to add an RBM. 3. In the Add RBM prompt, enter the MAC address for your RBM and click OK. 4. From the Edit RBM prompt, click Add to add a service flow. 5. Leave the Direction and QoS Type as their defaults. Click Add next to Classifiers to add a classification rule. Confidential - Restricted Use and Duplication Page 78 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 6. Select the “Destin MAC Address” box and set both values to 00:00:00:00:00:00 to allow for any destination MAC Address. 7. Click Add to add another service flow for the other direction. 8. Change the direction of this service flow to Uplink. 9. Click Add to add a classification rule for this service flow. Confidential - Restricted Use and Duplication Page 79 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 10. Select the Dest MAC Address checkbox and set both values to 00:00:00:00:00:00 to allow for any destination MAC Address. 11. Click Apply for the changes to take effect. You should now see a message that the RBM was successfully created and is now in the RBM table. Confidential - Restricted Use and Duplication Page 80 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 13. Select the green Save Config button. 14. The system should notify you that the running configuration has been successfully copied to the startup configuration. Alternately, for example, to configure a default pass-all, bidirectional service flow on the HM for one RBM on the X-100 system using the X-100 CLI, enter these commands: localhost# localhost# config terminal Entering configuration mode terminal localhost(config)# rbm-table rbm Confidential - Restricted Use and Duplication //Enter configuration mode //Add the MAC of the RBM to the RBM table Page 81 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide localhost(config-rbm-0c:a1:38:00:00:4f)# service-flows service-flow 1 Value for 'direction' [downlink,uplink]: downlink Release 1.0 //Create the first service flow for one direction Value for 'priority' ( ): 0 Value for 'qos service-type' [besteffort,guaranteed-bit-rate]: best-effort //Add the classification rule that allows for any destination MAC address localhost(config-service-flow-1)# classification rule 1 localhost(config-rule-1)# dst-mac-addr 00:00:00:00:00:00 localhost(config-rule-1)# dst-mac-mask 00:00:00:00:00:00 localhost(config-rule-1)# exit localhost(config-service-flow-1)# exit localhost(config-rbm-0c:a1:38:00:00:4f)# service-flows service-flow 2 Value for 'direction' [downlink,uplink]: uplink Value for 'priority' ( ): 0 Value for 'qos service-type' [besteffort,guaranteed-bit-rate]: best-effort localhost(config-service-flow-2)# classification rule 1 //Create the second service flow for the other direction //Add the classification rule that allows for any destination mac address localhost(config-rule-1)# dst-mac-addr 00:00:00:00:00:00 localhost(config-rule-1)# dst-mac-mask 00:00:00:00:00:00 localhost(config-rule-1)# commit //Commit the commands so that they take effect Commit complete. localhost(config-rule-1)# end localhost# copy run start Confidential - Restricted Use and Duplication //Copy the running configuration to the startup-configuration so that upon reboot this configuration will be loaded Page 82 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 14 Preambles, Flows, and Network Provisioning This chapter describes the role and use of preamble series indices and service flows in provisioning multiple X-100 clusters—a cluster being one Hub Module (HM) configured with its group of up to four Remote Backhaul Modules (RBMs) (referred to as 1:2, 1:3, or 1:4 clusters), as well as the provisioning tasks to follow for determining which RBMs from which clusters are allowed to register with a particular HM. • Preamble Functional Description • Preamble Operational Description • Provisioning Preambles • Provisioning HM Service Flow Definitions • Provisioning Multiple Clusters Within the Same Area 14.1 Preamble Functional Description The X-100 system uses Time Division Duplex (TDD) to transport wireless traffic data. TDD divides the data stream into frames. There are two frame size options: 3.125 msec and 5 msec. The frame consists of a number of Orthogonal Frequency-Division Multiplexing (OFDM) symbols. Each OFDM symbol is 97.1 µsec long with a 1/16 cyclic prefix option (91.4 µsec useful symbol time plus 6.25 µsec cyclic prefix; cyclic prefix of 1/8 is optional). The TDD frame is divided into a downlink sub-frame and an uplink subframe. The downlink to uplink ratio is user selectable through the Web UI or CLI: 50:50 or 65:35. The first symbol of the TDD frame is the ‘preamble’. This symbol is used for physical layer procedures such as synchronization, initial channel estimation, and noise and interference estimation. It is repeated in every frame. The preamble carries a uniquely defined signaling sequence. Up to 32 unique preamble indices can be configured on the X-100 system. Preamble indices identify and separate clusters of X-100 modules from each other, and enhance the receive operation performance of the X-100 system when different clusters are deployed in close geographical and/or RF proximity (RF proximity in this context is defined as two clusters that may or may not be geographically close, but significant power from one cluster is received by modules of the second cluster). Confidential - Restricted Use and Duplication Page 83 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Note: BLiNQ recommends that clusters in close geographic and RF proximity be identified with different preamble indices by assigning the HM a different preamble index from that of its RF neighbor. 14.2 Preamble Operational Description A Hub and RBM only register and talk to each other if they have the same preamble series value. If the RBM preamble index value does not match that of any HM, the RBM cannot connect or communicate to any HM. General notes: • A Hub can only have up to four RBMs registered at any one time. • There are 32 possible X-100 preamble series index values: 0 to 31. • HMs default to a preamble series value of ‘0’ (factory default). • RBMs default to a preamble series of ‘all’. That is, by default RBMs accept and register with any Hub preamble series index value (factory default). • Hub modules can only be configured with one preamble series index value, while RBMs can be configured to either a specific index value to match a Hub, or to automatically scan multiple index values to search for the best serving Hub Hubs default to a preamble series value of ‘0’, while RBMs default to a preamble series of ‘all’. Thus, by factory default, RBMs accept X-100 system service from and register with the best serving Hub pointed in their direction using any preamble series index value. With 32 preamble series index values available, you can provision up to 32 neighboring clusters within the same geographic area using, for example, preamble series index value 0 for the first 1x4 cluster, preamble series index value 1 for the second 1x4 cluster, preamble series index value 2 for the third 1x4 cluster, and so forth, all the way up to preamble series index value 31 for the 32nd 1x4 cluster. Such a configuration runs no risk of Hub-to-RBM registration faults between neighboring clusters. Note: Best Signal Indicator (BSI) is an RBM operating mode which allows the installer to easily determine the direction of the best quality signal from the best serving HM (refer to section 10.4.4 for details). When the field technician mounts the RBM and is in the process of searching for the optimum direction of the best serving HM using BSI, the RBM cycles through all preambles in Automatic Scan Mode (by factory default, unless set otherwise). Once the RBM identifies the preamble value for the best serving available HM, it locks on to that preamble value to allow the installer to pinpoint the best direction for the RBM to communicate with that HM. 14.3 Provisioning Preambles The default Preamble Series index settings can be seen in the ‘Setup (Radio Interface)’ sub-page of the X-100 WebUI for HMs and RBMs, respectively, under Radio Settings. Hub Radio Settings show the factory default of ‘0’ for Preamble Series, but can be set to use any single unique preamble index value from 0 to 31: Confidential - Restricted Use and Duplication Page 84 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 RBM Radio Settings show the factory default of ‘All’ for Preamble Series, but the box below the ‘All’ checkbox can be set to use any single unique preamble index value from 0 to 31: RBMs can also be set to two different preamble operating modes through the ‘Setup (Radio Interface)’ X-100 WebUI sub-page for RBMs: • Automatic Scan Mode—When the RBM preamble series index is set to “All” (the system default), the RBM scans the full range of preamble values to automatically determine the best serving HM available to it within its cluster. • Defined Preamble Mode—When the RBM preamble series index is set to a value between 0 to 31, it searches and seeks to connect and register to the best serving HM pointed in its direction within its cluster that matches its RBM preamble value setting. Note: Registering with the best serving HM through the Defined Preamble Mode can serve to reduce overall network interference because selecting the best RF server usually results in reduced transmitted power and consequently reduced network interference between clusters. Confidential - Restricted Use and Duplication Page 85 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 The Defined Preamble Mode is typically used when the operator seeks to connect to a specific hub module. For normal network operation, BLiNQ recommends that the preamble on RBMs be set to a specific index value using the Defined Preamble Mode rather than use Automatic Scan Mode. In Automatic Scan Mode an RBM can register with a weaker serving HM based on its initial startup orientation—completely missing a better serving HM for its location later on. Confidential - Restricted Use and Duplication Page 86 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Note: If an RBM loses communication with its HM (for example, in case the HM fails), if set to Automatic Scan Mode it attempts to identify and connect to another HM. Otherwise, if set to Defined Preamble Mode, the RBM scans for and identifies the best HM in its direction that matches its set preamble series definition value. 14.4 Provisioning HM Service Flow Definitions As explained in Chapter 13 “System Provisioning”, the HM has two service flow definitions for allowing communication to be established with a RBM, set through the ‘RBMs (RBM General)’ X-100 WebUI subpage for HMs: • Use Default Service Definition • Use Individual Service Definition Refer to section 13.3 “Provisioning Default Versus Individual Service Flows” for details. The typical use cases for the HM service flow definitions are: • Use Case 1—If the operator has one service flow definition that applies to all RBMs in the cluster, set the HM service flow definition to Use Default Service Definition. There is no need to provision the HM with the MAC addresses of the RBMs as the HM automatically discovers the RBM MAC addresses. • Use Case 2—If the operator wants to define individual service flow definitions for each RBM in the cluster on an RBM-by-RBM basis, set the HM service flow definition to Use Individual Service Definition. 14.5 Provisioning Multiple Clusters Within the Same Area With 32 preamble series index values available, you can provision up to 32 neighboring clusters within the same geographic area. Using ‘Use Case 2’ from section 14.4, you can, for example, provision three neighboring 1:4 clusters within the same geographic area using the X-100 WebUI: First 1:4 Neighbor Cluster: Using the X-100 WebUI for the HM: 1. Enter 0 in the ‘Preamble Series’ box of the Setup(Radio Interface) sub-page, under Radio Settings. 2. Click Apply for the changes to take effect. 3. Select the green Save Config button to copy the running configuration to the startup configuraton. Using the X-100 WebUI for RBM 1, RBM 2, RBM 3, and RBM 4, respectively: 1. Enter 0 in the ‘Preamble Series’ box of the (Radio Interface) sub-page, under Radio Settings. 2. Click Apply for the changes to take effect. 3. Select the green Save Config button to copy the running configuration to the startup configuraton. Confidential - Restricted Use and Duplication Page 87 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 Second 1:4 Neighbor Cluster: Repeat the steps done for the first 1x4 cluster, replacing the ‘Preamble Series’ value 0 with 1. Third 1:4 Neighbor Cluster: Repeat the steps done for the first 1x4 cluster, replacing the ‘Preamble Series’ value 0 with 2. Alternately, using ‘Use Case 2’ from section 14.4, the same three neighboring 1x4 clusters can be provisioned within the same geographic area using the X-100 CLI: First 1:4 Neighbor Cluster: Using the X-100 CLI for the HM: localhost(config)# radio localhost(config-radio)# preamble series-index 0 Using the X-100 CLI for RBM 1, RBM 2, RBM 3, and RBM 4, respectively: localhost(config-radio)# preamble scanning-mode scan-series-list localhost(config-radio)# preamble series 0 value 0 Second 1:4 Neighbor Cluster: Repeat the steps done for the first 1x4 cluster, replacing the ‘preamble series’ value 0 with 1. Third 1:4 Neighbor Cluster: Repeat the steps done for the first 1x4 cluster, replacing the ‘preamble series’ value 0 with 2. Further, if applicable for your network, this can be repeated all the way up to preamble series index value 31 for the 32nd 1x4 cluster. Confidential - Restricted Use and Duplication Page 88 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 15 Appendices 15.1 BLiNQ Wireless Devices and RF Safety All BLiNQ Networks products are evaluated to ensure they conform to the Radio Frequency (RF) energy emission safety limits adopted by the Federal Communications Commission (FCC). These evaluations are conducted using the compliance rules and guidelines adopted by both the FCC and Industry Canada. They are based on the results of the Maximum Permissible Exposure (MPE) studies by the FCC for mobile or fixed devices, which dictate MPE limits for human exposure to RF energy. Before selling any wireless networking device to the public, BLiNQ submits its devices to the FCC and Industry Canada for MPE (that is, RF emissions) studies and evaluation. These studies must demonstrate that the device meets the accepted regulatory limits for safe RF emissions, or it is not approved for sale by the FCC and thus cannot be sold to the public. This means that when wireless networking devices purchased from BLiNQ Networks are installed and operated as instructed, the RF emissions from the devices is equal to or less than the levels accepted as safe by the FCC and Industry Canada. When used as intended, BLiNQ wireless networking devices do not pose health risks. Like other devices that emit RF energy (such as computers and microwave ovens), the level of RF emissions from BLiNQ devices is too low to cause harm. Further, BLiNQ wireless networking devices emit far lower levels of RF energy than cellular and cordless telephones, and are almost always used further away from the body. To prevent unnecessary exposure to RF energy: • Always install the X-100 system so as to provide and maintain a minimum separation distance from all persons. • When the X-100 system is operational, avoid standing directly in front of Hub Module (HM) sectored antennas or in front of Remote Backhaul Modules (RBMs) and their internal antennas. RF energy fields may be present when the transmitter is on. • Do not install the X-100 system in a location where it is possible for people to stand or walk inadvertently in front of an antenna. Confidential - Restricted Use and Duplication Page 89 of 91 Issue 01 BLiNQ Networks Inc. X-100 User Guide Release 1.0 15.2 List of Acronyms BE BSI B-SON CINR CLI CoS CPE DARS DHCP DL DN DNS ECC EMS ETSI F/B FTP GBR GPS HM IEEE L2 LAN MAC MARA Mbps MCS MHz MIB MIMO MIMO-SM MRC NLOS NMS NOC OAM OFDM OSS PC PMP PTP QAM Table 13 List of Acronyms Best Effort Best Signal Indication Backhaul – Self-Organizing Network Carrier to Interference plus Noise Ratio Command Line Interface Class of Service Customer Premise Equipment Digital Audio Radio Service Dynamic Host Configuration Protocol Downlink Directory Number Domain Name System European Communications Committee Element Management System European Telecommunications Standards Institute Front to Back File Transfer Protocol Guaranteed Bit Rate Global Positioning System Hub Module Institute of Electrical and Electronics Engineers Layer 2 Local Area Network Media Access Control Managed Adaptive Resource Allocation Megabits per second Modulation and Coding Scheme Megahertz Management Information Base Multiple Input Multiple Output Multiple Output-Spatial Multiplexing Maximal Ratio Combining Non Line-of-Sight Network Management System Network Operations Center Operations, Administration & Maintenance Orthogonal Frequency Division Multiplexing Operations Support System Personal Computer Point-to-Multipoint Point-to-Point Quadrature Amplitude Modulation Confidential - Restricted Use and Duplication Page 90 of 91 Issue 01 BLiNQ Networks Inc. QoS RBM RF RFEC SFTP SISO SFP SLA SNMP S-VLAN TDM TDD ToS UL URL VLAN VSWR VDC WCS X-100 User Guide Release 1.0 Quality of Service Remote Backhaul Module Radio Frequency Radio Frequency Environment Characterization Secure File Transfer Protocol Single Input Single Output Small form-factor pluggable Service Level Agreement Simple Network Management Protocol Stacked VLAN Time Division Multiplexed Time Division Duplexing Terms of Service Uplink Universal Resource Locator Virtual Local Area Network Voltage Standing Wave Ratio Volts Direct Current Wireless Communications Services Confidential - Restricted Use and Duplication Page 91 of 91 Issue 01
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : gregzuliani Title : Microsoft Word - X-100_User_Guide_Rev_1_0_DRAFT_Dec_21_2012_FCC.docx Create Date : 2012:12:21 13:58:11 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2013:02:19 18:10:27-05:00 Metadata Date : 2013:02:19 18:10:27-05:00 Producer : GPL Ghostscript 8.15 Document ID : uuid:d104ec0f-64d0-4590-b33d-f0c273de3f9d Instance ID : uuid:4eb9203a-43d7-4906-bd91-a55cc53591c5 Page Count : 92 Author : gregzulianiEXIF Metadata provided by EXIF.tools