Blue Tower Communications EM915CV1-120 Radio Module for use in Meters User Manual 665094

Blue Tower Communications Ltd Radio Module for use in Meters 665094

User manual

Download: Blue Tower Communications EM915CV1-120 Radio Module for use in Meters User Manual 665094
Mirror Download [FCC.gov]Blue Tower Communications EM915CV1-120 Radio Module for use in Meters User Manual 665094
Document ID665094
Application IDl4vvMdaEiY/NwKaOQHD1hg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatMicrosoft Word - pdf
Filesize66.72kB (834049 bits)
Date Submitted2006-06-06 00:00:00
Date Available2006-06-06 00:00:00
Creation Date2006-06-06 10:19:40
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2006-06-06 10:19:40
Document TitleMicrosoft Word - 665094.DOC
Document CreatorPScript5.dll Version 5.2
Document Author: Administrator

TransPondIT® for CENTRON Installation Instructions
Models 915-120, 915-122
Description
Status Codes
®
The TransPondIT for CENTRON is an AMR module that has been
designed specifically for use with the CENTRON solid-state electric meter.
The TransPondIT sends meter data via radio frequency (RF) signal to a
®
®
®
receiving unit: HandTrackIT , FastTrackIT or CellTrackIT .
The TransPondIT for CENTRON can report the following codes:
Error Code Description
Reverse energy flow detected
Note: Please refer to the Technical Reference Manual TransPondIT for
CENTRON Solid State Electric Meter for further information on the product.
Metrology board failure
CAL pulse filtering
Required Equipment
NVRAM Failure
The following items are required for TransPondIT installation:
•
CENTRON meter (see compatibility chart)
®
®
•
Computer running Windows XP or Windows 2000 .
•
ConFigIT Electric (serial) [360-200-10]
•
RS232 cable [320-310-10]
•
ConFigIT cable [K442436-001] & connector [K42395-001]
•
ConFigIT software PC version 6.5 or higher
Installation Instructions
Multiple errors are possible: ConFigIT PC software will decode errors.
Meter Compatibility Chart
Form
Volts
Class
1S
120V
100
915120
Cat. No:
Remove the meters outer and inner covers being careful NOT to interfere
with the meters light pipe (see figures 1-3).
If applicable remove the black board-to-board connector and the existing
personality module (see figure 4).
Install the TransPondIT making sure that the PCB notches align with the
meter snaps (see figure 5).
Connect to the metrology board using the board-to-board connector.
Ensure that the connector is pushed fully home.
Refit both inner and outer meter covers.
2S
240V
200
915122
2S
240V
320
915122
3S
120V
20
915120
3S
240V
20
915122
4S
240V
20
915122
12S
120V
200
915120
Factory Default Settings
The TransPondIT is provided with the following default settings:
XPDR
ID
Meter
Reading
LCD test
(04xxxxxx)
Enabled
Display Reverse
format count?
Tx
Interval
UC
5*1
Decrement
5s
55
register
Where: ‘XPDR ID’ = TransPondIT ID and ‘UC’ refers to the utility code.
Warning
Fig 1: Inner cover
Fig 2: Remove cover
Fig 3: Light pipe
Changes or modifications to the product not expressly approved by Blue
Tower Communications Ltd could void the user’s authority to operate the
equipment. See also Federal Communications Commission and Industry
Canada information below.
FCC Information
TransPondIT for CENTRON devices 915-120 and 915-122 comply with part
15 of the FCC Rules. The devices are approved for use only in CENTRON
electricity meters and operation is subject to the following two conditions:
(1)
(2)
Fig 4: Board-to-board connector
Fig 5: Meter snap and PCB notch
Configuration Procedure
1.
2.
3.
4.
5.
The TransPondIT should only be configured when the meter is unpowered.
If the default settings (see ‘Factory Default Settings’ section) are
suitable for the installation then:
•
Simply plug the meter into the meter socket and apply mains. The
TransPondIT derives its power from the meter.
If the default settings need to be changed, then please refer to the
Technical Reference Manual for Centron TransPondIT for more detailed
information on setting specific parameters.
Verify that the TransPondIT is transmitting valid data and is reported
with the appropriate receiving device from the desired location.
Verify that the reported reading corresponds to the visual indication on
the meters LCD.
This device may not cause harmful interference and
This device must accept any interference received, including
interference that may cause undesired operation.
This device has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio or television reception,
which can be determined by turning the equipment on and off. The user is
encouraged to try to correct the interference by one or more of the following
measures:
•
•
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Industry Canada Information
Operation is subject to the following two conditions:
(1)
(2)
This device may not cause interference and
This device must accept any interference, including interference
that may cause undesired operation of the device.
Blue Tower Communications Ltd
www.bluetowercomms.com
US Office - One New Hampshire Ave, Suite 125, Portsmouth, NH 03801 Tel +1 603 766 1989
UK Office - Suite 1 Basepoint Business Centre, Aviation Park, Christchurch, Dorset BH23 6NW Tel +44 845 2300 156
© 2005 Blue Tower Communications Ltd. All rights reserved.
All company names, brand names, and product names are the property of their respective holder(s).
Blue Tower Communications Ltd reserves the right to change specifications, packaging, or other product information without notice. This publication could include technical inaccuracies or typographical errors.
CENTRON is a registered trademark of Itron (formerly Schlumberger Electricity, Inc.).
P/N 72005510 IM 05

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2006:06:06 10:19:40-04:00
Modify Date                     : 2006:06:06 10:19:40-04:00
Page Count                      : 1
Creation Date                   : 2006:06:06 14:19:40Z
Mod Date                        : 2006:06:06 14:19:40Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : Administrator
Metadata Date                   : 2006:06:06 14:19:40Z
Creator                         : Administrator
Title                           : Microsoft Word - 665094.DOC
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MS8EM915CV1-120

Navigation menu