Blue Tower Communications PTRANSPONDITV2 Pit Mounted Water Meter Transmitter User Manual Pit instr sheet

Blue Tower Communications Ltd Pit Mounted Water Meter Transmitter Pit instr sheet

User manual

Download: Blue Tower Communications PTRANSPONDITV2 Pit Mounted Water Meter Transmitter User Manual Pit instr sheet
Mirror Download [FCC.gov]Blue Tower Communications PTRANSPONDITV2 Pit Mounted Water Meter Transmitter User Manual Pit instr sheet
Document ID332363
Application IDl0CtwD6WccVYSlpEg3WsVg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize19.63kB (245436 bits)
Date Submitted2003-06-12 00:00:00
Date Available2003-06-12 00:00:00
Creation Date2003-06-10 09:25:14
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2003-06-10 09:25:14
Document TitleMicrosoft Word - Pit instr sheet.doc
Document CreatorADOBEPS4.DRV Version 4.50
Document Author: dwatts

900 Series Installation Instructions
Pit TransPondIT Model 915-44-24
Description
Warnings and Precautions
PIT INSTALLATION ONLY
The Pit TransPondIT Model 915-44-24 is designed for pit
installations only and attaches to an electronic coded register
(ECR) water meter. The Pit TransPondIT sends meter data via
®
®
RF signal to a receiving unit called HandTrackIT , FastTrackIT
®
or CellTrackIT .
Caution:
This product is only authorized for use in water pit
installations using metal enclosures, and only for belowground use. Changes or modifications not expressly
approved by Advanced Technology RAMAR Ltd could void
the user’s authority to operate the equipment. See FCC
Information below.
This sheet provides instructions needed to successfully connect
the Pit TransPondIT meter interface unit (MIU) to an ECR water
meter and to configure it. This guide is merely a supplement to
training in the operation of RAMAR 900 Series AMR equipment.
For training information, email training@ramartech.com.
Configuration
The Pit TransPondIT user parameters are set with the ConFigIT
box. The following picture illustrates typical configuration settings
for ECR meter.
ConFigIT Screen Settings
NOTE: This model is capable of interfacing with single pulse
meters. Refer to the Quick Reference Guide for more detail.
Required Tools and Equipment
The following items are recommended for proper installation of
the Pit TransPondIT:
®
•
3M Type UY2 gel-filled splice connectors and crimping
pliers
®
®
®
®
•
Computer running Windows XP , 2000 , 98 , or NT
®
•
ConFigIT Device (Mod Strike 14 or higher) & ConFigIT
Software Version 6.2 (or higher)
•
ConFigIT Cable Part Number 330-190-10 (Lemo) or 320300-10 (9 pin Dtype)
•
4 AA batteries or power cable
•
HandTrackIT, FastTrackIT, or CellTrackIT receiver with
connecting cable
Installation Procedure
Wire Connections – ECR
1.
2.
TransPondIT
Wires
ECR Water Meter
Wire 1
RED
Wire 2
BLACK
3.
Wire 3
GREEN
4.
123
5.
123
Wire Connections – Single Pulse Meter
Pulse Output
Ground
Tamper
– Wire 1
– Wire 2
– Wire 3
Transmitter
The transmission can be configured for different intervals. The
default interval is 5 seconds. (Refer to the detailed ConFigIT
operating instructions for more information.)
®
Connect the Pit TransPondIT to the meter register using 3M
Type UY2 gel-filled splice connectors.
Configure the Pit TransPondIT using the ConFigIT device.
Refer to the ConFigIT Manual for detailed information on
setting the user specific parameters.
NOTE: To use the Pit TransPondIT with encoded register
set the meter interface to ‘ECR’. To use with single pulse
meter, set to ‘Pulse’.
Mount the Pit TransPondIT using approved mounting
methods. Position the Pit TransPondIT so that the front of
the unit faces the direction of the receiver.
Verify that the signal is received with the appropriate
receiving device from the desired location.
Verify that the reading corresponds to the visual indication
on the meter register.
Tamper Reading (or Encoder Status)
With meter interface set to ‘ECR’:
Proper operation
64
No communication from register
68
Undefined data error from register
With meter register set to pulse, the tamper reading indicates
count of number of disconnections of tamper wire. The value
should be recorded at time of connection and any subsequent
increments should be investigated. The range is 0 to 63.
Obtaining Help
Contact Technical Support at the number listed below from 8:30
AM to 5:30 PM EST Monday through Friday.
AT RAMAR LLC PO Box 110127 Research Triangle Park, NC 27709 Toll Free: 1-888-98-RAMAR
© 2003 AT RAMAR LLC. All rights reserved. RAMAR, the AT RAMAR LLC logo, TransPondIT, ConFigIT, HandTrackIT, FastTrackIT and CellTrackIT are trademarks or registered
trademarks of Advanced Technology RAMAR Limited in the United States and/or other countries. All other company names, brand names, and product names are the property of their
respective holder(s). AT RAMAR LLC is an Agent for AT RAMAR Ltd. RAMAR reserves the right to change specifications or other product information without notice. This publication
could include technical inaccuracies or typographical errors. Mar 2003
Page 1 of 2
Instruction Sheet P/N 72001704 IM Rev 02
900 Series Installation Instructions
Pit TransPondIT Model 915-44-24
FCC Information
Example 2: Square Hand Hole
The Pit TransPondIT has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio or television
reception, which can be determined by turning the equipment on
and off, the user is encouraged to try to correct the interference
by one or more of the following measures:
--Reorient or relocate the receiving antenna
--Increase the separation between the equipment and
receiver
This device is only authorized for use in water pit installation
using metal enclosures comparable in mechanical
construction to the type specified in the filing ( see examples
below), and only for below-ground use.
Typical Pit Mounting Examples
The Pit TransPondIT is only approved for use in these types
of below-ground installations.
Placement of the Pit TransPondIT within the enclosure is
important for satisfactory performance.
By following these
examples, optimum results will be achieved.
The Square Hand Hole includes three metal castings; a base,
cylindrical body and square lid. The unit measures 7” wide by 12”
deep. The Pit TransPondIT is mounted in the center of the
bottom of the pit with the unit facing the direction of the reader.
Example 3: Round Meter Box
Example 1: Obround Yokebox
The Yokebox includes three metal castings; a base, upper body
and lid. The unit measures 10⅝” long by 7⅛” wide by 11” deep.
The round meter box includes three metal castings; a base,
body and lid. It measures 12“ wide by 15” deep. The Pit
TransPondIT is mounted in a vertical manner at the top of the
pit with the unit facing the direction of the reader.
The Pit TransPondIT is mounted in a vertical manner above the
water line with the unit facing the direction of the reader.
AT RAMAR LLC PO Box 110127 Research Triangle Park, NC 27709 Toll Free: 1-888-98-RAMAR
© 2003 AT RAMAR LLC. All rights reserved. RAMAR, the AT RAMAR LLC logo, TransPondIT, ConFigIT, HandTrackIT, FastTrackIT and CellTrackIT are trademarks or registered
trademarks of Advanced Technology RAMAR Limited in the United States and/or other countries. All other company names, brand names, and product names are the property of their
respective holder(s). AT RAMAR LLC is an Agent for AT RAMAR Ltd. RAMAR reserves the right to change specifications or other product information without notice. This publication
could include technical inaccuracies or typographical errors. Mar 2003
Page 2 of 2
Instruction Sheet P/N 72001704 IM Rev 02

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2003:06:10 09:25:14-04:00
Modify Date                     : 2003:06:10 09:25:14-04:00
Page Count                      : 2
Creation Date                   : 2003:06:10 13:25:14Z
Mod Date                        : 2003:06:10 13:25:14Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : dwatts
Metadata Date                   : 2003:06:10 13:25:14Z
Creator                         : dwatts
Title                           : Microsoft Word - Pit instr sheet.doc
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MS8PTRANSPONDITV2

Navigation menu