Blue Tower Communications PTRANSPONDITV9 AMR Transmitter User Manual 72006001 IM 0A

Blue Tower Communications Ltd AMR Transmitter 72006001 IM 0A

User Manual

Download: Blue Tower Communications PTRANSPONDITV9 AMR Transmitter User Manual 72006001 IM 0A
Mirror Download [FCC.gov]Blue Tower Communications PTRANSPONDITV9 AMR Transmitter User Manual 72006001 IM 0A
Document ID1083291
Application IDziLv9MxIaFrIEeUWipK1AQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize70.33kB (879123 bits)
Date Submitted2009-03-20 00:00:00
Date Available2009-03-20 00:00:00
Creation Date2009-03-03 10:50:27
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2009-03-03 10:50:27
Document TitleMicrosoft Word - 72006001_IM_0A.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: PETER WHITE

Installation Instructions
DataSource915-PIT
Description
6.
DataSource915-PIT is for PIT INSTALLATIONS ONLY. It attaches to the
following water meter registers:
•
Single pulse,
•
Master Meter Dual-Pulse,
•
Electronic encoded AMCO Scancoder,
•
Electronic encoded (ECR),
•
Electronic encoded Neptune / Schlumberger ARB V,
•
Electronic encoded ProRead/AutoDetect/E-CoderTM registers.*
7.
*With E-Coder registers DataSource915-PIT will read register ID and
reading only.
DataSource915-PIT sends meter data via radio frequency (RF) signal to a
receiving unit; HandTrackIT®, FastTrackIT® or CellTrackIT®.
Required Tools & Equipment
The following items are recommended for proper DataSource915-PIT
installation:
•
3M® Type UY2 gel-filled splice connectors and crimping pliers.
•
Suitable water resistant PU or Acrylic Potting Compound.
•
Computer running Windows XP®, 2000®, 98® or NT®.
®
•
ConFigIT device (Mod Strike 14 or higher) and ConFigIT
software version 6.5.07 or higher.
•
ConFigIT cable, part number 330-190-10 (Lemo) or 320-300-10
(9-pin Dtype).
•
4 AA batteries or power cable.
•
HandTrackIT, FastTrackIT, or CellTrackIT receiver with
connecting cable.
Mounting Instructions
8.
9.
Mount DataSource915-PIT as described in “Mounting Instructions”
section above.
Verify that the signal is received with the appropriate receiving
device from the desired location.
Verify that the reading corresponds to the visual indication on the
meter register.
NOTE: Max reading (pulse) = 16,777,215
Max reading (encoder) = 9,999,999 - left most digits are dropped.
If appropriate check that encoder status is reported as 0. Encoder
error codes are shown in the Encoder Status table below.
Error Codes
Tamper
Single pulse mode allows tamper readings of 1 through 63 which
indicates a count of the tamper wire disconnections. The value should be
recorded at the time of connection and any subsequent increments should
be investigated.
Dual-Pulse mode does not allow tamper detection because all wires are
used to count pulses.
Encoder Status
The encoders will display the following codes:
Error Code
1.
2.
3.
4.
5.
Connect DataSource915-PIT to the meter register using 3M Type
UY2 gel-filled splice connectors and gel cap crimping pliers.
If the default settings (see ‘Factory Default Settings’ section) are
suitable for the installation then:
•
DataSource915-PIT can be activated without ConFigIT by using
a small bar or horseshoe magnet. Ensure that the magnet is
held vertically over the center of DataSource915-PIT just below
the stripe.
If the default settings need to be changed, use the ConFigIT device
and software:
•
After performing as READ, select the register required from the
pull down list.
•
To use DataSource915-PIT with ProRead, AutoDetect or ECoder register, set meter interface mode to ‘AutoDetect’.
•
To use ID printed on the side of DataSource915-PIT case,
select ‘Use current ID’ button.
•
To enter new ID, select ‘Programmed by User’ button and enter
ID in the cell below button.
•
Set leak detection threshold to required value.
•
Turn on DataSource915-PIT by setting Transmit Interval
(default setting is every 5 seconds) to 5 or 10 secs for
FastTrackIt, 10 secs or greater for HandTrackIt. The transmit
interval for CellTrackIt operation depends on the required
sample rate.
Apply potting compound to the MIF wire cavity and ensure that the
Gel Caps are completely covered.
Ensure that the MIF wire terminations at the meter are waterproofed
in accordance with the Meter manufactures installation procedures.
No communication from register
65
Open wheel in register
66
Shorted wheel in register
68
Undefined data error from register
Leak
Mount DataSource915-PIT upright facing the direction of the receiver.
Avoid placing DataSource915-PIT on any metal walls or large metal
objects. Do not place DataSource915-PIT closer than 3 inches to metal pit
or vault lids.
Configuration & Installation Procedure
Description
64
Error Code
128
Description
Leak Flag
Wire Connections
123
123
Single Pulse Meters
Manufacturer
Model
Wire 1
Pulse
Wire 2
Ground
Wire 3
Tamper
AMCO/ ABB
PSM-T
Green
Blue
Blue
AMCO/ ABB
Pulsar
Red
Black
Black
Master Meter
Single-Pulser
Black
Green
Green
Badger®
RTR 3-wire
Green
Red
Black
Badger
DSI-IL & RTR 2-wire
Red
Black
Black
MetronFarnier
Spectrum
Red
Green
Green
Blue Tower Communications Inc
www.bluetowercomms.com
US Office - 201 Shannon Oaks Circle, Suite 200, Cary, NC 27511 Tel +1 919-654-7352
© 2009 Blue Tower Communications Inc. The information contained herein is the property of Blue Tower Communications Inc and is supplied without liability for errors or omissions. No part may be
reproduced or used except as authorized by contract or other written permission. All other company names, brand names, and product names are the property of their respective holder(s).
P/N 72006001 IM Rev 0A
Page 1 of 2
Installation Instructions
DataSource915-PIT
Dual Pulse Meters
Red
Green
Black
DataSource915-PIT monitors both meter switches and will increment
the counter after both have been closed in sequence.
DataSource915-PIT is mounted in the center of the pit’s bottom with the
unit facing the direction of the meter reader.
Encoders
Scancoder
Green
ECR
Red
Black
Green
Compatible with Hersey® Meters (Translator), MetronFarnier, Sensus/Invensys® and others.
ARB V
Black
Green
Red
ProRead/
AutoDetect
Black
Green
Red
Black
Red
Example 2: Obround Yokebox
Factory Default Settings
DataSource915-PIT is provided with the following default settings:
DataSource9
15-PIT
Interface
ID Source
Utility Code
915-PIT
Pulse
DataSource915-PIT
ID
49
The Yokebox includes three (3) metal castings: a base, upper body and
lid. The unit measures 10 5/8” long by 7 1/8” wide by 11” deep.
DataSource915-PIT is mounted in a vertical manner above the water line
with the unit facing the direction of the meter reader.
Warnings & Precautions
Warning: Changes or modifications to product not expressly approved by
Blue Tower Communications Inc could void the user’s authority to operate
the equipment. See FCC information below.
This sheet provides instruction needed to successfully connect, configure
and read DataSource915-PIT for the water meters listed above in the
description section. This sheet is merely a supplement to training in the
operation of the Blue Tower DataStream AMR system. For training
information, contact Blue Tower Communications Inc directly.
FCC Information
This equipment complies with FCC RF radiation exposure limits set forth
for an uncontrolled environment. The antenna(s) used for this transmitter
must be installed to provide a separation distance of at least 20 cm from
all persons and must not be co-located or operating in conjunction with
any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
This device is only authorized for use in water pit installations with
metal enclosures and only for below ground use. Pit construction
should be comparable to type specified in the FCC filing. See the
following examples.
Example 3: Round Meter Box
The round meter box includes three (3) metal castings: a base, body and
lid. It measures 12” wide by 15” deep. DataSource915-PIT is mounted in
a vertical manner at the top of the pit with the unit facing the direction of
the meter reader.
Pit Mounting Examples
DataSource915-PIT is only approved for use in the following types of
below-ground installations. Placement of the DataSource915-PIT within
the enclosure is important for satisfactory performance. Follow the below
examples for optimum performance.
Note: A light colored DataSource915-PIT is used for illustration purposes
only. A blue DataSource915-PIT should be used in the following
installations for optimum performance.
Example 1: Square Hand Hole
The Square Hand Hole includes three (3) metal castings: a base,
cylindrical body and square lid. The unit measures 7” wide by 12” deep.
Blue Tower Communications Inc
www.bluetowercomms.com
US Office - 201 Shannon Oaks Circle, Suite 200, Cary, NC 27511 Tel +1 919-654-7352
© 2009 Blue Tower Communications Inc. The information contained herein is the property of Blue Tower Communications Inc and is supplied without liability for errors or omissions. No part may be
reproduced or used except as authorized by contract or other written permission. All other company names, brand names, and product names are the property of their respective holder(s).
P/N 72006001 IM Rev 0A
Page 2 of 2

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 2
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2009:03:03 10:50:27
Modify Date                     : 2009:03:03 10:50:27
Title                           : Microsoft Word - 72006001_IM_0A.doc
Creator                         : PScript5.dll Version 5.2.2
Author                          : PETER WHITE
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MS8PTRANSPONDITV9

Navigation menu