BodyMedia BT24 SenseWear (R) biotransceiver User Manual BT 2 4 WS LIT indd
BodyMedia, Inc. SenseWear (R) biotransceiver BT 2 4 WS LIT indd
Contents
- 1. Blood glucose manual
- 2. Blood pressure manual
- 3. Weigh scale manual
Weigh scale manual
biotransceiver for use with Tanita® HD351 Weight Scale Operating Manual ® 4 Smithfield Street 11th Floor Pittsburgh, PA 15222 USA P.412.288.9901 F.412.288.9902 www.bodymedia.com BT-2.4-WS-LIT Rev.1 BodyMedia International Srl Via G. Balzaretti, 15 20133 Milan, Italy P.+39-02-2774121 F.+39-02-27741250 www.bodymedia.eu © Copyright 2007 BodyMedia, Inc. TABLE OF CONTENTS Important Information About the SenseWear biotransceiver . . . . . . . . . . . . . . . . . . . . . . . . 02 Taking a Reading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Sending a Reading to SenseWear® armband . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Sending a Reading to SenseWear® wireless gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Copyright, Patent and Trademark Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 FCC Statement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 NOTE: Read these instructions and the Warnings and Cautions on pages 2-4 before using the Body Monitoring System. Important Information About the SenseWear® biotransceiver Intended Use The SenseWear® biotransceiver can be used to collect data from OEM biometric monitors and upload it to the SenseWear® PRO3 armbands or SenseWear® wireless gateway for applications such as: nutritional diagnostics, metabolic diseases, pediatrics, pulmonary and cardiac studies, geriatrics, internal medicine, occupational medicine, neurology, psychiatrics, sleep screening, and in general anywhere it is necessary to monitor caloric and energy consumption, movement, physical activity, quality of life, lifestyle, behavior and/or stress. WARNINGS This product complies with the general requirements for a safe medical device under applicable directives. However, this product alone is not meant to substitute for proper medical diagnosis, care, or treatment. Any decisions based on the data from this device should be made only by medical personnel and should consider the condition and lifestyle of the subject tested. The SenseWear® biotransceiver should not be used for life critical applications; improper usage may result in harm or even death to the wearer. This product is non-defibrillation proof. Do not get the device close to other devices that can cause electromagnetic interferences of any nature. EQUIPMENT not suitable for use in the presence of a FLAMMABLE ANAESTHETIC MIXTURE WITH AIR or WITH OXYGEN OR NITROUS OXIDE. Medical electrical equipment needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided on pages 5-8. Portable and mobile RF communications equipment can affect medical electrical equipment. Important Information About the SenseWear® biotransceiver WARNINGS Important Information About the SenseWear® biotransceiver CAUTIONS The equipment or system should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, the equipment or system should be observed to verify normal operation in the configuration in which it will be used. Handling Avoid exposing the biotransceiver to extreme temperatures, direct sunlight, moisture, sand, dust, or mechanical shock. The SenseWear® biotransceiver should not be used in airplanes, hospitals or locations where cellular telephones or electronic devices are prohibited. Dispose of device in accordance with local, state, federal, or country specific regulations. Keep the SenseWear® biotransceiver out of reach of children. The product contains smaller, removable parts which can become chocking hazards. Water resistance DO NOT IMMERSE THE BIOTRANSCEIVER IN WATER. The biotransceiver is not designed to be used underwater or to come in continuous contact with water. To prevent a shock hazard, never use the armband in water environments (e.g., in the shower, swimming pool, or rain). IPX0 classified. Maintenance Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. If the biotransceiver is dropped, ensure that it is working properly and not physically damaged before relying on readings. Cleaning Moisten a soft cloth or towel with mild disinfectant soap and water. Wipe and dry the biotransceiver. Never use solvents to clean the biotransceiver, only for disinfecting (see below). Ordinary Protection, not protected against ingress to moisture. CAUTIONS Disinfecting Wipe biotransceiver with soft cloth dampened with 70% isopropyl alcohol. Allow biotransceiver to dry for 5-10 minutes before using DO NOT STERILIZE THIS UNIT. Batteries Batteries may explode or leak and can cause burn injury if recharged, disposed of in fire, or disassembled. Dispose of properly. For further information about the disposal battery, please following manufacturer’s instructions. Batteries may present a choking hazard for small children. Remove battery if biotransceiver will not be used for over 30 days. Important Information About the SenseWear® biotransceiver Important Information About the SenseWear® biotransceiver Patient Environment Guidance and Manufacturer’s Declaration - Immunity The BT-2.4-WS (SenseWear® biotransceiver) is intended for use in the electromagnetic environment specified below. The customer or user of the BT-2.4-WS should ensure that it is used in such an environment. 2.5m 1.5m IEC 60601 Test Level Immunity Test 1.5m 1.5m Compliance Level Electromagnetic Environment - Guidance ESD IEC 61000-4-2 ±6kV Contact ±8kV Air ±6kV Contact ±8kV Air Floors should be wood, concrete, or ceramic tile. If floors are synthetic, the r/h should be at least 30%. EFT IEC 61000-4-4 ±2kV Mains ±1kV I/Os N/A N/A Surge IEC 61000-4-5 ±1kV Differential ±2kV Common N/A N/A Voltage Dips/ Dropout IEC 61000-4-11 >95% Dip for 0.5 Cycles N/A N/A 3A/m Power frequency magnetic fields should be that of a typical commercial or hospital environment. Computer and Wireless Communicator Diagram not to scale. Guidance and Manufacturer’s Declaration - Emissions The BT-2.4-WS (SenseWear® biotransceiver) is intended for use in the electromagnetic environment specified below. The customer or user of the BT-2.4-WS should ensure that it is used in such an environment. Emissions Test Compliance RF Emissions CISPR 11 Group 1 RF Emissions CISPR 11 Class B Harmonics IEC 6100-3-2 Class A Flicker IEC 6100-3-3 Complies Electromagnetic Environment - Guidance 60% Dip for 5 Cycles The BT-2.4-WS uses RF energy only for its inernal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. The BT-2.4-WS is suitable for use in all establishments, including domestic, and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. 30% Dip for 25 Cycles >95% Dip for 5 Seconds Power Frequency 50/60Hz 3A/m Magnetic Field IEC 61000-4-8 Important Information About the SenseWear® biotransceiver Guidance and Manufacturer’s Declaration - Emissions The BT-2.4-WS (SenseWear® biotransceiver) is intended for use in the electromagnetic environment specified below. The customer or user of the BT-2.4-WS should ensure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment - Guidance Important Information About the SenseWear® biotransceiver Field strenghts from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, and electromagnetic site survey should be considered. If the measured field strength in the location in which the BT-2.4-WS is used exceeds the applicable RF compliance level above, the BT-2.4-WS should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocationg the BT-2.4-WS. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. Portable and mobile communications equipment should be separated from BT-2.4-WS by no less than the distances calculated/listed below: Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 3 Vrms 150 kHz to 80 MHz 3 V/m 80 MHz to 2.5 GHz N/A • D=(3.5/V1)(Sqrt P) 3 V/m • D=(3.5/E1)(Sqrt P) 80 to 800 MHz • D=(7/EI)(Sqrt P) 800 MHz to 2.5 GHz where P is the max power in watts and D is the recommended separation distance in meters. FIeld strengths from fixed transmitters, as determined by an electromagnetic site survey, should be less than the compliance level in each frequency rangeb. Interference may occur in the vicinity of equipment containing a transmitter symbol: NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people Recommended Separations Distances for the BT-2.4-WS The BT-2.4-WS (SenseWear® biotransceiver) is intended for use in the electromagnetic environment in which radiated disturbances are controlled. The customer or user of the BT-2.4-WS can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF Communications Equipment and the BT-2.4-BG as recommended below, according to the maximum output power of the communications equipment. Max Output Power (Watts) Separation (m) 150kHz to 80MHz D=(3.5/V1)(Sqrt P) Separation (m) 80 to 800MHz D=(3.5/V1)(Sqrt P) Separation (m) 800MHz to 2.5GHz D=(7/E1)(Sqrt P) 0.01 0.1166 0.1166 0.2333 0.1 0.3689 0.3689 0.7378 2.3333 1.1666 1.1666 10 3.6893 3.6893 7.3786 100 11.6666 11.6666 23.3333 For transmitters rated at a maximum output power not listed above, the recommended seperation distance d in meters (m) can be determined using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz, the seperation distance for the higher frequency range applies. NOTE 2 These guideleines may not apply in all situations. Electromagnetic propogation is affected by absorption and reflection from structures, objects and people. Important Information About the SenseWear® biotransceiver Follow operating instructions. Caution Taking a Reading After you have read and understood the manufacturer’s manual for taking readings, the following instructions will tell you how to send a reading. For more information about your weight scale device, please consult the Tanita® Operating Instructions in the Tanita® Weight Scale box. Tested to applicable safety standards. The Waste Electrical and Electronic Equipment Regulations indicates separate collection for electrical and electronic equipment. Identification code of Notified Body involved: 0051. Sending a Reading to SenseWear® armband 1. Make sure that the scale is on a hard, even surface. Do not place on carpet. 2. Locate the weight scale with built-in SenseWear® biotransceiver within 2 meters (6 feet) of SenseWear® PRO3 armband. 3. Press the armband button (figure 1). Note: the armband must be on-body at time of button press (indicated by a short vibration by the armband). EMC Alert Mark for non-ionizing radiation . Classification of the device, as per 93/42 directives : IIa (rule 10) Certification procedure : 93/42/EEC, Annex VI, VII. Identification code of Notified Body involved: 0051 2.400 - 2.483 GHz Transmit Power Class 8 - Less than 10mW output power Duty Cycle Class 4 - permitted to operate at 100% duty cycle Receiver Class 3 - Standard reliable SRD communication media Conforms to UL STD 60950 Certified to CSA C22.2 No. 950 figure 1 figure 2 10 Sending a Reading to SenseWear® armband 4. Press 1 on the weight scale (figure 2) and wait for 0.0 reading and a beep before stepping on to scale. Wait for another beep before stepping off the scale. 5. The biotransceiver will immediately retrieve data off the weight scale. As soon as retrieval is complete, the biotransceiver will send data to the armband. 6. The armband will also beep and vibrate once the transfer is successfully completed. Sending a Reading to SenseWear® wireless gateway 1. Place the weight scale with SenseWear® biotransceiver within 5 meters (15 feet) of the SenseWear® wireless gateway. 2. Press 1 on the weight scale (figure 2) and wait for 0.0 reading and a beep before stepping on to scale. Before stepping off the scale, wait for another beep. 3. The biotransceiver will immediately retrieve data off the weight scale. As soon as retrieval is complete, the biotransceiver will send data to the wireless gateway. 4. Please consult the SenseWear® wireless gateway Operating Manual for further details. FCC Statement NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit separate from the receiver. • Consult the dealer or an experienced radio/TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC 47CFR 15C TCB - 47 CFR Part 15 Subpart C Intentional Radiator Certification Test Copyright, Patent and Trademark Notices Patents and patents pending. The BodyMedia® biotransceiver is covered by one or more of the following patents when used with a BodyMedia® armband (e.g., SenseWear® armbands and bodybugg™ armbands): United States Pat. Nos.: 6,527,711, 6,595,929, 6,605,038, 7,020,508; European Patent Nos.: 1,292,217, 1,292,218; and various worldwide patents pending. SenseWear® and BodyMedia® are registered trademarks of BodyMedia, Inc. Accu-Chek Advantage is a registered trademark of Roche Diagnostic Corporation. FCC 47CFR 15B clA - 47 CFR Part 15 Subpart B Unintentional Radiators Class A Verification UL 60601-1 - UL Standard for Safety Medical Electrical Equipment, Part 1: General Requirements for Safety First Edition CENELEC EN 60601-1-2 - 2001 - Medical Electrical Equipment Part 1-2: General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests IEC 60601-1-2: 2001 CENELEC EN 60601-1-1 - Medical Electrical Equipment - Part 1: General Requirements for Safety Collateral Standard: Safety Requirements for Medical Electrical Systems. 11 CAN/CSA-C22.2 No.606.1-M90 ETSI EN 301 489-1 - Electromagnetic Compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) Standard for Radio Equipment and Services; Part 1: Common Technical Requirements V1.3.1 ETSI EN 301 489-3 - (Draft) Electromagnetic Compat. and Radio Spectrum Matters (ERM); Harmonized EN for ElectroMag. Compatibility (EMC) of Radio Comms. Equip. & Srvs.; Pt. 3: Specific Conditions for ShortRange Devices (SRD) Operating on Freqs Between 9 KHz and 40 GHz V1.3.1 ETSI EN 300 440-1 V1.3.1 (2001-07) Electromagnetic compatibility and Radio spectrum Matters (ERM);Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range 12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Create Date : 2007:01:11 10:12:12-05:00 Modify Date : 2007:01:11 10:12:12-05:00 Page Count : 7 Creation Date : 2007:01:11 15:12:12Z Mod Date : 2007:01:11 15:12:12Z Producer : Acrobat Distiller 5.0 (Windows) Author : quang Metadata Date : 2007:01:11 15:12:12Z Creator : quang Title : BT-2.4-WS-LIT.inddEXIF Metadata provided by EXIF.tools