Bogen Communications Car Amplifier Esys1 M Users Manual ESYS Diagrams
ESYS3 wire ESYS3 wire
BCWHT wire BCWHT wire
ESYS1 wire ESYS1 wire
ESYS4 wire ESYS4 wire
BCIRS wire BCIRS wire
2015-02-02
: Bogen Bogen-Bogen-Communications-Car-Amplifier-Esys1-M-Users-Manual-483946 bogen-bogen-communications-car-amplifier-esys1-m-users-manual-483946 bogen pdf
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
SYSTEMS WIRING DIAGRAMS ESYS1(M) MAX BATT CHG. The (BCWHT) Wireless Handheld Microphone operates solely on channel "B". The BCWHT Mic is available with the ESYS “M” package. MI BCWBT ENHANCER IR Receiver BCWHT Wireless Handheld MIC BCIRS Unit 1 FRONT VIEW BCIRS Unit 2 The Enhancer Bodypack Transmitter (BCWBT) output level is controlled by the bodypack's volume control. REAR VIEW Gold Seal Series Amplifier ACOUSTIC EQ O U T Volume Control for Enhancer The Enhancer Receiver's mixed output level (for each channel) is controlled by the "A" and "B" Volume Controls. 62.5 MIC 2 MIC 3 MIC 4 MIC 5/TEL MIC 6/AUX 1 (see NOTE 1) FEEDBACK CONTROL GOLD SEAL SERIES MIC 1 Fig. A 125 250 500 1K 2K 4K 8K 12K 16K + 12 AUX 2 FRONT VIEW + 12 MASTER POWER 9 4 4 6 4 6 4 6 4 6 4 6 4 6 ACOUSTIC EQ 6 6 3 2 8 2 8 8 2 2 8 2 8 2 8 8 2 0 0 3 0 0 10 10 0 10 0 10 0 10 FRONT VIEW Recessed Volume Control. ground Fig. B (see NOTE 2) WIRE COLOR BLACK BROWN RED ORANGE YELLOW GREEN BLUE VIOLET GREY WHITE BLACK 6 12 125 CONTOUR IN 0 10 8 2 OUT 200 315 500 800 1.2K 2K 3.1K 5K 8K IN OUT APHEX AURAL EXCITER R Master Volume Control for System Output LINK switch set to “IN” + REAR VIEW + + REAR VIEW ESYS1 NOTES: 1. When switch is set to "FEEDBACK CONTROL," the amplifier can be used to improve "Max Volume before Feedback". (see Fig. A) 25V COMMON 4W 2W 1W 1/2W 1/4W 1/8W ---------------------- 10 + BROWN + 0 FEEDBACK CONTROL 12 - 25V CUT 10 6 9 Both LINK Connection jumpers should remain in place S86T725PG8WVR Ceiling Speakers (4) 0 O U T 4 2. Cut/Remove bare wire tips off of unused speaker leads on all speakers. (see Fig. B) 3. If necessary, individual speaker output levels can be adjusted by the Speaker’s Recessed Volume Control or by Power Taps. (see Fig. C) Fig. C (see NOTE 3) 25V 25V 25V 25V ESYS2(M) MAX BATT CHG. The (BCWHT) Wireless Handheld Microphone operates solely on channel "B". The BCWHT Mic is available with the ESYS “M” package. MI ENHANCER IR Receiver BCWBT BCIRS Unit 1 FRONT VIEW BCWHT Wireless Handheld MIC BCIRS Unit 2 The Enhancer Bodypack Transmitter (BCWBT) output level is controlled by the bodypack's volume control. REAR VIEW Gold Seal Series Amplifier ACOUSTIC EQ O U T Volume Control for Enhancer The Enhancer Receiver's mixed output level (for each channel) is controlled by the "A" and "B" Volume Controls. GOLD SEAL SERIES 62.5 MIC 2 MIC 1 MIC 3 MIC 4 MIC 5/TEL 125 250 500 1K 2K 4K 8K 12K FRONT VIEW 16K + 12 + 12 AUX 2 MIC 6/AUX 1 Fig. A (see NOTE 1) FEEDBACK CONTROL POWER MASTER 9 4 4 6 4 6 4 6 4 6 4 6 4 6 ACOUSTIC EQ 6 6 3 2 8 2 8 8 2 2 8 2 8 2 8 8 2 0 0 3 0 10 0 10 10 0 0 10 0 10 0 10 0 10 O U T 6 0 10 2 FEEDBACK CONTROL 6 4 8 9 12 - 12 125 200 315 500 800 1.2K 2K 3.1K 5K 8K FG15W Surface Mount Speakers (4) IN OUT APHEX AURAL EXCITER CONTOUR IN OUT Both LINK Connection jumpers should remain in place R Master Volume Control for System Output FRONT VIEW + 8 ground LINK switch set to “IN” REAR VIEW REAR VIEW ESYS2 NOTES: 8 1W 2W 1W + 8 8 15W 7.5W 4W + + 2W 1W 8 8 Series Connected 4W 2W 1W 8 8 (see NOTE 2) 8 7.5W LINE + 8 4W INPUT 15W 7.5W LINE + 8 + 2W 1W LINE 4W INPUT 15W 7.5W 8 + 8 + LINE 15W Fig. B INPUT 2W INPUT 4W 8 FG15W set to 1. When switch is set to "FEEDBACK CONTROL," the amplifier can be used to improve "Max Volume before Feedback". (see Fig. A) 7.5W LINE 15W 8 8 Series Connected 2. On each FG15W speaker, turn the Tap Selector setting to 8 . (see Fig. B) ESYS3(M) MAX BATT CHG. ENHANCER IR Receiver The (BCWHT) Wireless Handheld Microphone operates solely on channel "B". The BCWHT Mic is available with the ESYS “M” package. MI BCWBT BCIRS Unit 1 FRONT VIEW BCWHT Wireless Handheld MIC BCIRS Unit 2 The Enhancer Bodypack Transmitter (BCWBT) output level is controlled by the bodypack's volume control. REAR VIEW Gold Seal Series Amplifier ACOUSTIC EQ O U T Volume Control for Enhancer The Enhancer Receiver's mixed output level (for each channel) is controlled by the "A" and "B" Volume Controls. GOLD SEAL SERIES 62.5 MIC 2 MIC 1 MIC 3 MIC 4 MIC 5/TEL Fig. A (see NOTE 1) FEEDBACK CONTROL MIC 6/AUX 1 125 250 500 1K 2K 4K 8K 12K 16K + 12 AUX 2 FRONT VIEW + 12 MASTER POWER 9 4 4 6 4 6 4 6 4 6 4 6 4 6 ACOUSTIC EQ 6 6 3 2 8 2 8 8 2 2 8 2 8 2 8 8 2 0 0 3 0 CSD2X2 Ceiling Speakers (4) 10 0 10 0 10 0 10 RED ground Fig. B BLACK + 10 0 10 O U T 12 125 CONTOUR IN OUT 200 315 500 800 1.2K 2K 3.1K 5K 8K 8 IN OUT APHEX AURAL EXCITER LINK switch set to “IN” + 10 R Master Volume Control for System Output + YELLOW 0 2 FEEDBACK CONTROL 6 12 - 25V (see NOTE 2) 0 6 9 Both LINK Connection jumpers should remain in place FULL VIEW CUT 0 10 4 TOP VIEW + + REAR VIEW ESYS3 NOTES: 1. When switch is set to "FEEDBACK CONTROL," the amplifier can be used to improve "Max Volume before Feedback". (see Fig. A) 2. Cut/Remove bare wire tips off of unused speaker leads. (see Fig. B) Fig. C (see NOTE 3) 25V 25V 25V 25V 3. If necessary, individual speaker output levels can be adjusted by the Speaker’s Power Tap Selector Switch. (see Fig. C) ESYS4(M) MAX BATT CHG. ENHANCER IR Receiver The (BCWHT) Wireless Handheld Microphone operates solely on channel "B". The BCWHT Mic is available with the ESYS “M” package. MI BCWBT BCIRS Unit 1 FRONT VIEW BCWHT Wireless Handheld MIC BCIRS Unit 2 The Enhancer Bodypack Transmitter (BCWBT) output level is controlled by the bodypack's volume control. REAR VIEW ACOUSTIC EQ O U T Volume Control for Enhancer The Enhancer Receiver's mixed output level (for each channel) is controlled by the "A" and "B" Volume Controls. Fig. A (see NOTE 1) 62.5 MIC 2 MIC 3 MIC 4 MIC 5/TEL MIC 6/AUX 1 (see NOTE 2) FEEDBACK CONTROL GOLD SEAL SERIES MIC 1 125 250 500 Gold Seal Series Amplifier Fig. B 1K 2K 4K 8K 12K 16K + 12 AUX 2 FRONT VIEW + 12 MASTER POWER 9 4 4 6 4 6 4 6 4 6 4 6 4 6 ACOUSTIC EQ 6 6 3 2 8 2 8 8 2 2 8 2 8 2 8 8 2 0 0 3 0 10 0 10 0 10 0 10 0 10 0 10 0 10 O U T 6 0 10 2 FEEDBACK CONTROL 6 4 8 9 Remove 12 - 12 125 CONTOUR IN HFCS1 Ceiling Speakers (4) Fig. C 4 1.2K 2K 3.1K 5K 8K IN OUT APHEX AURAL EXCITER 4 Master Volume Control for System Output 2 2 1 61 61 V07 4 V001 23 61 23 61 8 R 4 8 8 LINK switch set to “IN” 32 16 32 100V 16 1 70V 6 800 + ground HFCS1 set to 500 LINK Connection jumper should remain in place 8 4 16 2 1 315 FRONT VIEW (see NOTE 3) 2 OUT 200 ++__ ++__ 16 REAR VIEW ++__ ++__ REAR VIEW ESYS4 NOTES: 1. On rear panel of the amplifier, remove the "LINK" connection. (see Fig. A) 2. When switch is set to "FEEDBACK CONTROL," the amplifier can be used to improve "Max Volume before Feedback". (see Fig. B) 3. On each HFCS1 speaker, turn the Tap Selector setting to 16 . (see Fig. C) 16 16 16 16 54-7891-02C 0606
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 for Macintosh Keywords : ESYS Diagrams Create Date : 2006:05:31 09:20:12-04:00 Modify Date : 2006:06:01 11:59:17-04:00 Creator Tool : QuarkXPress: pictwpstops filter 1.0 Metadata Date : 2006:06:01 11:59:17-04:00 Format : application/pdf Title : ESYS Diagrams Creator : John Britnell Description : 54-7891-02C Subject : ESYS Diagrams Document ID : uuid:3e59447b-f0a8-11da-b474-000a959c6a9a Instance ID : uuid:945c3110-f187-11da-829c-000a959b0540 Page Count : 4 Page Layout : SinglePage Author : John BritnellEXIF Metadata provided by EXIF.tools