Bominwell Robotics PEEK Peek Quickview Inspection System User Manual
Shenzhen Bominwell Robotics Co., Ltd. Peek Quickview Inspection System Users Manual
User Manual
User manual-peek Introduction: Outstanding IP68 protection range could be capable to operate underwater of 10 meters. Peek main apply to uncomplicated structure pipe or industrial containers for detail inspection included recording video, saving image, generating report even in corrosively gas and corrosively liquid environment. Customer can make a direct decision based on the report Highlights Cameras equipped With 2.13 million pixels Optimized LED lighting technology Specification Camera Sensor 1/2 8”213MP CMOS Distinguishability 1920 X 1030 Lens 32X Special function Three stream/ image rotation/ motion detection Illuminanl High beam 10W'2 LED Low beam iW’S LED Power resource Battery DC‘lZV BUUDmAh Working time Working:8H Standby 20H Extension Dar Length Adjustable. Standard.7m Material Highestrength tibre Laser ranging Measuring distance 0 9-150m Accuracy :0.6m Distinguishaoility ‘chm Operating -15’t 450K Temperature Storage -25’( -B5< Temperature Protection range IP68 Application Municipal pipelines inspection. applicable to all kind of municipal pipeline’s shift inspection and emergency detection Facilities detection. industrial equipment internals can be detected, eliminate accident hidden danger Tank car detection: detect the tank car s working status to avoid any damage an risk System and main component Hégn-strengtn fibre extension rod HD camera Detector structures Menu ngh beam High—strength fibre extension rod The\Ignlweighttelescuping pole high-strength fibre rod is HD camera Low beam normally 3 meters \ongmptlonal 12 meters) It has spring suspension [or stability and fine height adjustment Assembly high—strength fibre extension rod Match snap Stretch the rod Jolnt available Tlghten the screws Tightening Inflation Camera pressure 1) Once used In lnflammable and exploslve dangerous sltuatlon please accordlng to the requirements that inflate inert gas to the Camera system 2) "waterproof requirement l5 necessary, please filled WIth hellum or dry aIr 3) Pressure llmlting device is needed when lnflating, no more than 125 PSI pressure adjustment 4) Once the air pressure in the camera is below or above the prescribed alr scope, the control system will be Issued a warning. Clients need Io cut off the camera module power to ensure the safety of the equipment and personnel. Charoino connector Inflatable cover Connection of lhe operating panel and Peek 1, Turn on the power bottom oflhe operating panel /WIreless module IHD camera 2. Open lhe software on the operalmg panel and finalize the connection of the camera. Power bottom Wireless module power bottom HD camera power bofiom N oted: 1 Detection enVironment in more than 10 meters water depth Is forbidden 2 Equipment connection process in charging is forbidden: 3 Working in dangerous gases environment is forbidden. 4 lntlating Equipment In working status is forbidden, 5 Once the pressure system is anomaly. it is needed that reView and solve the error before working 6 It must be in strict accordance With the specifications and the correct assembly steps 7 It is strictly prohibited to disassemblythe equipment Please inform the manufacturer once have any puzzles Any unauthorized disassembly and modification Will lead to the warranty terms not available. FCC STATEMENT: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: [1)This device may not cause harmful interference, and [2) This deVice must accept any interference received, including interference that may cause undesired operation Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment NOTE: This equipment has been tested and found to complyWith the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance With the instructions, may cause harmful interference to radio communications However, there is no guarantee that interference Will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Radiation Exposure Statement: This equipment complies With FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated With minimum distance 20cm between the radiator & your body.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : anbotek Create Date : 2016:07:12 15:25:23+08:00 Modify Date : 2016:07:12 15:25:23+08:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Title : <463A5C616D79BDD3CAD6B5C4B0B8D7D35C32303136C4EA352D36D4C25C3031313630353837394920B2A9C3FACEAC20C7B1CDFBBEB53F5065656B20CDF5D6BEB7BD2D616D792D4643432D494428D0C5BFC6295CD7CAC1CF4F4B5C55736572204D616E75616C2E646F6378> Creator : anbotek Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 9.3.3 (Windows) Document ID : uuid:f7672727-0ae4-4eb3-84d2-5775fa9d0e02 Instance ID : uuid:6f497024-abc5-4d25-b85b-90929056262c Page Count : 5EXIF Metadata provided by EXIF.tools