Bominwell Robotics PEEK Peek Quickview Inspection System User Manual

Shenzhen Bominwell Robotics Co., Ltd. Peek Quickview Inspection System Users Manual

User Manual

Download: Bominwell Robotics PEEK Peek Quickview Inspection System User Manual
Mirror Download [FCC.gov]Bominwell Robotics PEEK Peek Quickview Inspection System User Manual
Document ID3078117
Application IDaYmuxVDsJ6vl3ScL1vakCQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize66.79kB (834871 bits)
Date Submitted2016-07-27 00:00:00
Date Available2016-07-27 00:00:00
Creation Date2016-07-12 15:25:23
Producing SoftwareAcrobat Distiller 9.3.3 (Windows)
Document Lastmod2016-07-12 15:25:23
Document TitleUsers Manual
Document CreatorPScript5.dll Version 5.2.2
Document Author: anbotek

User manual-peek
Introduction:
Outstanding IP68 protection range could be capable to operate underwater of 10 meters.
Peek main apply to uncomplicated structure pipe or industrial containers for detail
inspection included recording video, saving image, generating report even in corrosively
gas and corrosively liquid environment. Customer can make a direct decision based on
the report
Highlights
Cameras equipped With 2.13 million pixels
Optimized LED lighting technology
Specification
Camera Sensor 1/2 8”213MP CMOS
Distinguishability 1920 X 1030
Lens 32X
Special function Three stream/ image rotation/ motion detection
Illuminanl High beam 10W'2 LED
Low beam iW’S LED
Power resource Battery DC‘lZV BUUDmAh
Working time Working:8H Standby 20H
Extension Dar Length Adjustable. Standard.7m
Material Highestrength tibre
Laser ranging Measuring distance 0 9-150m
Accuracy :0.6m
Distinguishaoility ‘chm
Operating -15’t 450K
Temperature
Storage -25’( -B5<
Temperature
Protection range IP68
Application
Municipal pipelines inspection. applicable to all kind of municipal pipeline’s shift inspection
and emergency detection
Facilities detection. industrial equipment internals can be detected, eliminate accident
hidden danger
Tank car detection: detect the tank car s working status to avoid any damage an risk
System and main component
Hégn-strengtn fibre extension rod
HD camera
Detector structures
Menu
ngh beam
High—strength fibre extension rod
The\Ignlweighttelescuping pole high-strength fibre rod is
HD camera
Low beam
normally 3 meters
\ongmptlonal 12 meters) It has spring suspension [or stability and fine height adjustment
Assembly high—strength fibre extension rod
Match snap
Stretch the rod
Jolnt
available
Tlghten the screws
Tightening
Inflation Camera pressure
1) Once used In lnflammable and exploslve dangerous sltuatlon please accordlng to the
requirements that inflate inert gas to the Camera system
2) "waterproof requirement l5 necessary, please filled WIth hellum or dry aIr
3) Pressure llmlting device is needed when lnflating, no more than 125 PSI pressure
adjustment
4) Once the air pressure in the camera is below or above the prescribed alr scope, the
control system will be Issued a warning. Clients need Io cut off the camera module power
to ensure the safety of the equipment and personnel.
Charoino connector
Inflatable cover
Connection of lhe operating panel and Peek
1, Turn on the power bottom oflhe operating panel /WIreless module IHD camera
2. Open lhe software on the operalmg panel and finalize the connection of the camera.
Power bottom
Wireless module power bottom
HD camera power bofiom
N oted:
1 Detection enVironment in more than 10 meters water depth Is forbidden
2 Equipment connection process in charging is forbidden:
3 Working in dangerous gases environment is forbidden.
4 lntlating Equipment In working status is forbidden,
5 Once the pressure system is anomaly. it is needed that reView and solve the error
before working
6 It must be in strict accordance With the specifications and the correct assembly steps
7 It is strictly prohibited to disassemblythe equipment Please inform the manufacturer
once have any puzzles Any unauthorized disassembly and modification Will lead to the
warranty terms not available.
FCC STATEMENT:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
[1)This device may not cause harmful interference, and
[2) This deVice must accept any interference received, including interference that may
cause undesired operation
Warning: Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment
NOTE: This equipment has been tested and found to complyWith the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance With the instructions, may cause harmful interference to radio
communications However, there is no guarantee that interference Will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies With FCC radiation exposure limits set forth for an uncontrolled
environment This equipment should be installed and operated With minimum distance
20cm between the radiator & your body.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : anbotek
Create Date                     : 2016:07:12 15:25:23+08:00
Modify Date                     : 2016:07:12 15:25:23+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Title                           : <463A5C616D79BDD3CAD6B5C4B0B8D7D35C32303136C4EA352D36D4C25C3031313630353837394920B2A9C3FACEAC20C7B1CDFBBEB53F5065656B20CDF5D6BEB7BD2D616D792D4643432D494428D0C5BFC6295CD7CAC1CF4F4B5C55736572204D616E75616C2E646F6378>
Creator                         : anbotek
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.3.3 (Windows)
Document ID                     : uuid:f7672727-0ae4-4eb3-84d2-5775fa9d0e02
Instance ID                     : uuid:6f497024-abc5-4d25-b85b-90929056262c
Page Count                      : 5
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AIPK-PEEK

Navigation menu