Bontec HM-T011 Remote Keyless Entry System User Manual HM T011 FCC IC

Bontec Co., Ltd. Remote Keyless Entry System HM T011 FCC IC

Users Manual

Download: Bontec HM-T011 Remote Keyless Entry System User Manual HM T011 FCC IC
Mirror Download [FCC.gov]Bontec HM-T011 Remote Keyless Entry System User Manual HM T011 FCC IC
Document ID600347
Application IDz0Mc/s1Mud/93DVBhHrHmg==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize21.12kB (263964 bits)
Date Submitted2005-11-08 00:00:00
Date Available2005-11-08 00:00:00
Creation Date2005-10-28 17:04:57
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2005-10-28 17:06:46
Document TitleHM_T011_FCC_IC.xls
Document CreatorPScript5.dll Version 5.2
Document Author: pttno3

Remote Keyless Entry
(HM-T011)
MOBIS Co., Ltd.
#80-9,MABOOK-RI, GUSEONG-EUP, YONGIN-SHI, GYUNGGI,449-910,KOREA
- INDEX -
- An outline
- Description of Transmitter
- Regulatory Information
An outline of Transmitter
1. How to use HM-T011
- HM-T011 is Remote Keyless System.
- This unit controll door lock, unlock, panic, tail gate unlock/glass open with wireless.
- This unit consist of Transmitter(HM-T011)
- Lock button push , then door lock.
- Unlock button push, then door unlock.
- Tail Gate Unlock/Glass Open button push, then tail gate or tail gate glass unlock.
- Panic button push, then Panic
2. Introduction of Transmitter(HM-T011)
- Transmitter has four button
- Button marking are LOCK, UNLOCK, TAIL GATE UNLOCK/GLASS OPEN, PANIC
- Transmitter use thee voltage battery
- Freqency is 315Mhz
- Modulation item is SAW Resonator
- Transmitter use Rolling code algorithm
Description of Transmitter
1. PRIMARY FUNTION
- Remote door lock/unlock
- Remote tail gate unlock/glass open, panic
- LED turn on ( When button is pushed )
- Operating distance :10 m over
- Id input(setting mode)
2. ELECTRICAL CHARACTERISTICS
TRANSMITTER
model name
Operating voltage
3 V DC
Consumption current
Max 15mA
Operating frequency
315㎒
Power
10mW under
Sensitivity
Operating temperature
-20 ~ +60℃
ETC
FM modulation
3. DESCRIPTION MODE
1) Mode
Mode
ID INPUT
(Setting Mode)
Normal Mode
B+
ON
ON
KEYLESS
OFF
ACC
OFF
IG
OFF
SETTING
use equipment
OFF
2) Id input(Setting Mode)
When Setting Mode, lock button push,
4. OPERATING DIAGRAM
1) TRANSMITTER
A) DATA FRAME
B) DATA FORMAT
LOGIC "0"
LOGIC "1"
C) TRANSMISSION SPECIFICATION
- BAUD RATE : 625bps
- CODING METHOD : MANCHESTER
- TRANSMISSION BIT COUNT : 1 FRAME = 234BIT
- TRANSMISSION TIME : 377.4msec
Regulatory Information
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES
Operation is subject to the following two conditions;
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired operation.
CAUTION: changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2005:10:28 17:04:57+09:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2005:10:28 17:06:46+09:00
Metadata Date                   : 2005:10:28 17:06:46+09:00
Format                          : application/pdf
Title                           : HM_T011_FCC_IC.xls
Creator                         : pttno3
Document ID                     : uuid:e1332de9-5780-4d1d-9cc2-1a5a7e1f0c4f
Instance ID                     : uuid:fc5066eb-94bf-4122-8521-ac9ba8d26670
Has XFA                         : No
Page Count                      : 6
Author                          : pttno3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PLNHM-T011

Navigation menu