Bosch Security Systems 0407-6 User Manual Prog
Bosch Security Systems Inc Prog
manual
Installation Instructions RF835 TriTech® Microwave/PIR Intrusion Detector with Pet Immunity 1.0 Overview TriTech Motion Sensor 2.0 Specifications • • • • • • General • Power supplied by four 1.5V AA Alkaline Batteries. • • • • The RF835 TriTech® detector uses passive infrared technology, Microwave technology, and artificial intelligence to detect motion and provides freedom from false alarms. When motion is detected the unit sends an alarm signal to the control panel. • • • • Typical current draw is 100 micro-amps with LED disabled. Typical battery life is two to three years (has not been verified by Underwriters Laboratories). Operating temperature range of +32°F to +120°F (0°C to +49°C) Microwave Frequency: 10.525 Ghz (U.L. Listed) RF Transmit Frequency: 304.00 MHz Options: Low Profile Swivel Mount Bracket (use of this bracket may reduce range and dead zone areas). Coverage area 35 ft. by 35 ft. (10.7 m by 10.7 m) Internal coverage pointability -6° to -10° Vertical and ±10° Horizontal. Masking kit provided to block portions of coverage area. Field selectable sensitivity options of Standard and Intermediate. Three minute transmitter lockout time after alarm extends battery life. Timed Walk Test Mode automatically disables LED after setup to extend battery life. Cover activated Tamper indication. Optional wall activated Tamper is included. Pet Immunity capabilities have not been verified by UL. RF Transmitter • Integral RF transmitter capable of transmitting 500 feet open air. (Actual acceptable transmitter range should be verified for each installation). • Transmits low battery report (trouble) to the control panel. • Transmits tamper • Transmits supervisory signal to the control panel every 64 minutes. 3.0 Installation 3.1 Open the cover 3.2 Open base 3.3 REMOVE BATTERY PLUG Insert screwdriver into notches and gently twist to open 3.4 Select a mounting location Insert four (4) size AA Alkaline batteries in the battery holder per the guides imprinted on the holder Notches DO NOT MOUNT OUTDOORS 3.5 Observe the Pet Immunity mounting recommendations 6.5 Ft (2 M) Don't point where pets can climb Don't point at stairs Mount the detector 6 1/2 feet (2 meters) above the floor 3.6 Avoid: 3.7 Observe the Pet Immune Area Moving objects Hot or cold air directed onto sensor NO NO 3.8 Observe Receiver Range Moisture Direct or reflected sunlight NO OK Upper areas are not pet immune 500’ max (300 meters) Panel Receiver Pet Immune Area 7/99 Copyright © 1999 Detection Systems, Inc. RF835 Installation Instructions P/N 40142A PRELIMINARY Detection Systems, Inc., 130 Perinton Parkway Fairport, New York, USA 14450-9199 (716) 223-4060 • (800) 289-0096 • Fax: (716) 223-9180 3.9 Mount the Detector 3.10 Set the Vertical Adjust 3.11 Set the PIR Sensitivity Corner mount Thinwall breakaway for wall tamper switch Vertical Adjust Screw Flush mount INT STD -6 - 10 MAX MIN MW -6 - 10 Loosen the Vertical Adjust Screw. Adjust the board to - 5 In non-pet applications only, if look-down is desired, peel away the look-down mask. Do not remove the clear plastic lens. INT Peel away the mask INT STD MAX Set as low as possible for normal operation MIN MAX 3.16 Coverage Patterns Meters 1.6 20 3.2 4.8 TOP VIEW 6.4 9.6 15 LZ 15 10 6.4 9.6 10 15 B-L N-Q 20 25 30 -5° 35 B CDE F GH I J K L 15 LZ W-X R-U,Z Feet N R W S O Z P T X UQ 20 Feet 4.8 3.2 SIDE VIEW Remove masking for Look Down zone. 10 Meters 1.6 11.2 10 -6 - 10 MIN Set Microwave to MIN If necessary, adjust the Microwave MIN 10 MAX INT STD MIN MW Red = Alarm STD MW -6 - 10 MAX Green = PIR detect Yellow = MW detect Cause Unit Alarm Microwave Activation (walk test) PIR Activation (walk test) Warmup Period After Power-Up Microwave or PIR failure. Replace Unit. 3.15 Uncover Look Down Lens INT STD 3.14 Adjust the Microwave Replace cover Wait 30 minutes after installing batteries to begin Walk test. LED Condition Steady Red Steady yellow Steady Green Flashing Red Flashing Red (fourpulse sequence) STD 3.13 Walk Test 3.12 LED Operation INT STD INT (Refer to section 5.0) Corner mount For pet applications, set jumper to STD. PIR Sensitivity Selection Pins 20 25 30 35 RF835 TriTech Lens 4.0 Programming Pattern Testing in Walk Test Mode Removing and replacing the cover will start a 90 second Walk See your Control Panel Programming Guide for information. Test Mode. During this Test Mode, any activity in the sensor’s cov5.0 Setup for Non-Pet Applications erage pattern will cause a transmitted alarm and LED activation. Each alarm will also extend the Test Mode for an additional 90 Select the vertical starting angle from the chart. To adjust the vertical seconds. starting angle for the desired mounting height and range, loosen the vertical adjust screw and slide the board up, to point the PIR 6.0 Other Information pattern down. Note the settings on the vertical adjust scale (Figure Maintenance: At least once a month, the range and coverage 3.9). should be verified using the walk test mode. To ensure continual daily operation, the end user should be instructed to walk through Mounting Range the far end of the coverage pattern. This ensures an alarm output 20 ft. (6.1 m) 35 ft. (10.7 m) Height prior to arming the system. 6.5 ft. (2 m)* -7 -5* Pattern Masking: The PIR coverage pattern may be masked 7.0 ft. (2.1 m) -9 -6 using the masking stickers provided with the unit. 8.0 ft. (2.4 m) -10 -7 NOTE: Masking only eliminates the PIR portion of the coverage * Required for pet immunity. and has no effect on the Microwave pattern. U.S. Patent Numbers: #4,660,024, #4,764,755, #5,077,548, NOTE: The vertical angle must be set at -5° for installations contain#5,208,567, #5,262,783, and #5,450,062. Other patents pending. ing pets. NOTE: During the warm-up period, the tricolor LED will flash red until the unit has stabilized (approximately 30 minutes) and has seen no movement for two seconds. When the LED stops flashing, the detector is ready to be tested. With no motion in the protection area, the LED should be OFF. If the LED is on, recheck the protection area for disturbances affecting the Microwave (yellow) or PIR (green) technologies. (See Figure 3.11.) Page 2 FCC Notice This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry and Science Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable operation. Changes or modifications not expressly approved by Detection Systems, Inc. can void the user's authority to operate the equipment. Copyright © 1998 Detection Systems, Inc. RF835 TriTech Installation Instructions
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 2 Creator : C:\WINDOWS\Desktop\Work In Prog Create Date : 1999:07:09 13:34:27 Title : Prog Author : kkrueger Producer : Acrobat PDFWriter 4.0 for WindowsEXIF Metadata provided by EXIF.tools