Installation Instructions
RF835 TriTech®
Microwave/PIR Intrusion Detector
with Pet Immunity
1.0 Overview
TriTech Motion Sensor
2.0 Specifications
•
•
•
•
•
•
General
• Power supplied by four 1.5V AA Alkaline Batteries.
•
•
•
•
The RF835 TriTech® detector uses passive infrared technology, Microwave technology, and artificial intelligence to detect motion and provides freedom from false alarms. When motion is detected the unit
sends an alarm signal to the control panel.
•
•
•
•
Typical current draw is 100 micro-amps with LED disabled.
Typical battery life is two to three years (has not been verified by
Underwriters Laboratories).
Operating temperature range of +32°F to +120°F (0°C to +49°C)
Microwave Frequency: 10.525 Ghz (U.L. Listed)
RF Transmit Frequency: 304.00 MHz
Options: Low Profile Swivel Mount Bracket (use of this bracket may
reduce range and dead zone areas).
Coverage area 35 ft. by 35 ft. (10.7 m by 10.7 m)
Internal coverage pointability -6° to -10° Vertical and ±10° Horizontal.
Masking kit provided to block portions of coverage area.
Field selectable sensitivity options of Standard and Intermediate.
Three minute transmitter lockout time after alarm extends battery life.
Timed Walk Test Mode automatically disables LED after setup to extend
battery life.
Cover activated Tamper indication. Optional wall activated Tamper is
included.
Pet Immunity capabilities have not been verified by UL.
RF Transmitter
•
Integral RF transmitter capable of transmitting 500 feet open air. (Actual
acceptable transmitter range should be verified for each installation).
•
Transmits low battery report (trouble) to the control panel.
•
Transmits tamper
•
Transmits supervisory signal to the control panel every 64 minutes.
3.0 Installation
3.1 Open the cover
3.2 Open base
3.3 REMOVE BATTERY PLUG
Insert
screwdriver
into notches
and gently
twist to open
3.4 Select a mounting location
Insert four (4)
size AA Alkaline
batteries in the
battery holder per
the guides imprinted
on the holder
Notches
DO NOT MOUNT
OUTDOORS
3.5 Observe the Pet Immunity mounting recommendations
6.5 Ft
(2 M)
Don't
point
where
pets
can
climb
Don't
point
at
stairs
Mount the detector 6 1/2 feet
(2 meters) above the floor
3.6 Avoid:
3.7 Observe the Pet Immune Area
Moving objects
Hot or cold air
directed onto
sensor
NO
NO
3.8 Observe Receiver Range
Moisture
Direct or
reflected
sunlight
NO
OK
Upper
areas
are
not
pet
immune
500’ max
(300 meters)
Panel Receiver
Pet Immune Area
7/99
Copyright © 1999 Detection Systems, Inc.
RF835 Installation Instructions P/N 40142A
PRELIMINARY
Detection Systems, Inc., 130 Perinton Parkway
Fairport, New York, USA 14450-9199
(716) 223-4060 • (800) 289-0096 • Fax: (716) 223-9180
3.9 Mount the Detector
3.10 Set the Vertical Adjust
3.11 Set the PIR Sensitivity
Corner mount
Thinwall
breakaway for
wall tamper
switch
Vertical Adjust Screw
Flush mount
INT
STD
-6
- 10
MAX
MIN
MW
-6
- 10
Loosen
the Vertical
Adjust Screw.
Adjust the board to - 5
In non-pet applications only, if look-down is
desired, peel away the
look-down mask.
Do not remove
the clear
plastic
lens.
INT
Peel away
the mask
INT
STD
MAX
Set as low
as possible for
normal operation
MIN
MAX
3.16 Coverage
Patterns
Meters
1.6
20
3.2
4.8
TOP VIEW
6.4
9.6
15
LZ
15
10
6.4
9.6
10
15
B-L
N-Q
20
25
30
-5°
35
B CDE F GH I J K L
15
LZ W-X R-U,Z
Feet
N R W S O Z P T X UQ
20
Feet
4.8
3.2
SIDE VIEW
Remove masking for Look Down zone.
10
Meters
1.6
11.2
10
-6
- 10
MIN
Set Microwave to MIN
If necessary,
adjust the Microwave
MIN
10
MAX
INT
STD
MIN
MW
Red =
Alarm
STD
MW
-6
- 10
MAX
Green =
PIR detect
Yellow =
MW detect
Cause
Unit Alarm
Microwave Activation (walk test)
PIR Activation (walk test)
Warmup Period After Power-Up
Microwave or PIR failure.
Replace Unit.
3.15 Uncover Look Down Lens
INT
STD
3.14 Adjust the Microwave
Replace cover
Wait 30 minutes after installing
batteries to begin Walk test.
LED Condition
Steady Red
Steady yellow
Steady Green
Flashing Red
Flashing Red (fourpulse sequence)
STD
3.13 Walk Test
3.12 LED Operation
INT
STD
INT
(Refer to section 5.0)
Corner mount
For pet applications,
set jumper to STD.
PIR
Sensitivity
Selection Pins
20
25
30
35
RF835 TriTech Lens
4.0 Programming
Pattern Testing in Walk Test Mode
Removing and replacing the cover will start a 90 second Walk
See your Control Panel Programming Guide for information.
Test Mode. During this Test Mode, any activity in the sensor’s cov5.0 Setup for Non-Pet Applications
erage pattern will cause a transmitted alarm and LED activation.
Each alarm will also extend the Test Mode for an additional 90
Select the vertical starting angle from the chart. To adjust the vertical
seconds.
starting angle for the desired mounting height and range, loosen
the vertical adjust screw and slide the board up, to point the PIR 6.0 Other Information
pattern down. Note the settings on the vertical adjust scale (Figure
Maintenance: At least once a month, the range and coverage
3.9).
should be verified using the walk test mode. To ensure continual
daily operation, the end user should be instructed to walk through
Mounting
Range
the far end of the coverage pattern. This ensures an alarm output
20 ft. (6.1 m)
35 ft. (10.7 m)
Height
prior to arming the system.
6.5 ft. (2 m)*
-7
-5*
Pattern Masking: The PIR coverage pattern may be masked
7.0 ft. (2.1 m)
-9
-6
using the masking stickers provided with the unit.
8.0 ft. (2.4 m)
-10
-7
NOTE: Masking only eliminates the PIR portion of the coverage
* Required for pet immunity.
and has no effect on the Microwave pattern.
U.S.
Patent
Numbers: #4,660,024, #4,764,755, #5,077,548,
NOTE: The vertical angle must be set at -5° for installations contain#5,208,567, #5,262,783, and #5,450,062. Other patents pending.
ing pets.
NOTE: During the warm-up period, the tricolor LED will flash red until
the unit has stabilized (approximately 30 minutes) and has
seen no movement for two seconds. When the LED stops flashing, the detector is ready to be tested. With no motion in the
protection area, the LED should be OFF. If the LED is on, recheck the protection area for disturbances affecting the Microwave (yellow) or PIR (green) technologies. (See Figure 3.11.)
Page 2
FCC Notice
This device complies with Part 15 of the FCC Rules and with RSS-210 of
Industry and Science Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that
may cause undesirable operation. Changes or modifications not expressly
approved by Detection Systems, Inc. can void the user's authority to operate
the equipment.
Copyright © 1998 Detection Systems, Inc.
RF835 TriTech Installation Instructions

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 2
Creator                         : C:\WINDOWS\Desktop\Work In Prog
Create Date                     : 1999:07:09 13:34:27
Title                           : Prog
Author                          : kkrueger
Producer                        : Acrobat PDFWriter 4.0 for Windows
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ESV-0407-6

Navigation menu