Bosch Security Systems DCNWDU02 DCN Discussion Unit User Manual
Bosch Security System BV DCN Discussion Unit
Contents
- 1. User Manual Part 1
- 2. User Manual Part 2
User Manual Part 1
DCN Wireless Installation and User Instructions en Wireless discussion system DCN Wireless | Installation and User Instructions | Important Safeguards Important Safeguards Before you install or operate the DCN Wireless digital congress network, you must read the Important Safety Instructions. The Important Safety Instructions are supplied together with the central control unit. Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 3 DCN Wireless | Installation and User Instructions | Disclaimers Disclaimers CobraNet is a trademark of Peak Audio — a division of Cirrus Logic, Inc. — in the United States and/or other countries. Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 4 DCN Wireless | Installation and User Instructions | About this manual en | 5 About this manual Signs Function The Installation and User Instructions shows each admonition with a sign. The sign shows the effect if you do not obey the instruction. The Installation and User Instructions gives the installers and the operators the necessary data to install, configure and operate a basic DCN Wireless Discussion System. Admonition General sign for cautions and warnings. When you want to make a more advanced DCN Wireless Discussion System, you also need information from the DCN Next Generation Installation and User Instructions. Admonition Risk of electric shock. The product index (refer to appendix B) tells you where you can find more data about devices that can be connected to DCN Wireless. Digital version The Installation and User Instructions is available as a digital file (Portable Document File, PDF). When the PDF refers you to a location that contains more data, you can click the text to go there. The text contains hyperlinks. Admonitions and notes The Installation and User Instructions uses admonitions and notes. The admonition gives the effect if you do not obey the instructions. These are the types: • Caution If you do not obey the caution, you can cause damage to the equipment. • Warning If you do not obey the warning, you can cause personal injury or death. Bosch Security Systems | 2007-11 | 9922 141 70691 en Admonition Risk of electro-static discharges (refer to the section ’Electro-static discharges’). The sign that is shown along with a note gives more data about the note itself. Note General sign for notes. Note Refer to another information source. DCN Wireless | Installation and User Instructions | About this manual en | 6 Electro-static discharges Conversion tables Electro-static discharges can damage electric components. You must take measures to prevent electro-static discharges when you touch PCBs (refer to figure 1). Length, mass and temperature are in SI units. Refer to the data below to change SI units to imperial units. table 2: Conversion of units of length 1 in = 25.4 mm 1 mm = 1 in = 2.54 cm 1 cm = 1 ft = 0.3048 m 1m= 1 mi = 1.609 km 1 km = 0.03937 in 0.3937 in 3.281 ft 0.622 mi table 3: Conversion of units of mass 1 lb = 0.4536 kg 1 kg = 2.2046 lb table 4: Conversion of units of pressure 1 psi = 68.95 hPa 1 hPa = 0.0145 psi Note 1 hPa = 1 mbar. 12 11 10 figure 1: ESD prevention table 1: ESD prevention No. Description Safety isolating transformer Distribution supply box Conductive compartment trays Electro-static voltage sensor Cotton overall Conductive floor mat Conductive boots/heel grounding protectors Conductive stool Strap (resistance 0.5 to 1.0 MΩ) 10 Common reference point 11 Conductive bench top 12 Supply ground Bosch Security Systems | 2007-11 | 9922 141 70691 en table 5: Conversion of units of temperature °F = --- ⋅ °C + 32 °C = --- ⋅ ( °F – 32 ) DCN Wireless | Installation and User Instructions | Table of Contents en | 7 Table of Contents Important Safeguards ..................................................................................................................................................3 Disclaimers ......................................................................................................................................................................4 About this manual .........................................................................................................................................................5 Table of Contents ..........................................................................................................................................................7 Section 1 - System Design and Planning............................................................................................................. 11 1. Wireless network design ........................................................................................................................................................... 12 1.1 Introduction ............................................................................................................................................................................ 12 1.2 Limits ....................................................................................................................................................................................... 12 1.3 Frequency band .................................................................................................................................................................... 13 2. DCN design .................................................................................................................................................................................. 15 2.1 Introduction ............................................................................................................................................................................ 15 2.2 Limits ....................................................................................................................................................................................... 15 3. Optical network design .............................................................................................................................................................. 16 3.1 Introduction ............................................................................................................................................................................ 16 3.2 Calculation tool ..................................................................................................................................................................... 16 3.3 Limits ....................................................................................................................................................................................... 16 3.4 Control capacity ................................................................................................................................................................... 16 3.5 Power capacity ..................................................................................................................................................................... 16 3.6 Cabling ................................................................................................................................................................................... 17 3.7 Example layouts .................................................................................................................................................................... 19 4. Camera control ............................................................................................................................................................................. 22 4.1 Introduction ............................................................................................................................................................................ 22 4.2 Scenarios ............................................................................................................................................................................... 22 5. Infra-red wireless language distribution .................................................................................................................................. 22 6. CobraNet ....................................................................................................................................................................................... 23 7. User set-up .................................................................................................................................................................................... 23 7.1 Public areas and walkways ................................................................................................................................................ 23 7.2 Headphones/headsets ........................................................................................................................................................ 23 7.3 Speaking distance ............................................................................................................................................................... 23 7.4 Interpreter booths ................................................................................................................................................................. 23 8. Device set-up ................................................................................................................................................................................ 24 8.1 General ................................................................................................................................................................................... 24 8.2 Cables ..................................................................................................................................................................................... 24 8.3 Temperature .......................................................................................................................................................................... 24 8.4 Ventilation .............................................................................................................................................................................. 24 8.5 Cleaning ................................................................................................................................................................................. 24 8.6 Storage ................................................................................................................................................................................... 24 8.7 Acoustic feedback ............................................................................................................................................................... 25 9. Technical data .............................................................................................................................................................................. 26 9.1 System electrical and electro-acoustic characteristics ............................................................................................... 26 9.2 Environmental conditions ................................................................................................................................................... 27 9.3 Safety ...................................................................................................................................................................................... 27 9.4 Electro-magnetic compatibility .......................................................................................................................................... 28 9.5 Wireless devices .................................................................................................................................................................. 28 9.6 Miscellaneous ....................................................................................................................................................................... 29 Section 2 - Central Devices ...................................................................................................................................... 31 Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Table of Contents en | 8 10. DCN-WCCU Wireless Central Control Unit ......................................................................................................................... 32 10.1 Introduction ............................................................................................................................................................................ 32 10.2 Controls, connectors and indicators ............................................................................................................................... 32 10.3 Internal settings .................................................................................................................................................................... 33 10.4 Installation .............................................................................................................................................................................. 37 10.5 External connections ........................................................................................................................................................... 37 10.6 Configuration menu ............................................................................................................................................................. 43 11. DCN-WAP Wireless Access Point ......................................................................................................................................... 54 11.1 Introduction ............................................................................................................................................................................ 54 11.2 Firmware ................................................................................................................................................................................. 54 11.3 Controls, connectors and indicators ............................................................................................................................... 54 11.4 Installation .............................................................................................................................................................................. 55 11.5 External connections ........................................................................................................................................................... 57 11.6 Configuration ......................................................................................................................................................................... 57 11.7 Operation ............................................................................................................................................................................... 59 12. System configuration .................................................................................................................................................................. 61 12.1 Introduction ............................................................................................................................................................................ 61 12.2 Initialization ............................................................................................................................................................................. 61 12.3 Wireless modes .................................................................................................................................................................... 62 12.4 Microphone modes .............................................................................................................................................................. 63 12.5 Repetition rate ....................................................................................................................................................................... 64 12.6 Audio routing modes ........................................................................................................................................................... 64 12.7 Attention chimes ................................................................................................................................................................... 66 12.8 Erase requests-to-speak and speakers ........................................................................................................................... 66 12.9 Floor distribution ................................................................................................................................................................... 66 12.10 Intercom .................................................................................................................................................................................. 67 13. System operation ......................................................................................................................................................................... 68 13.1 Start the system .................................................................................................................................................................... 68 13.2 Stop the system .................................................................................................................................................................... 68 Section 3 - Contribution Devices............................................................................................................................ 69 14. DCN-WDU Wireless Discussion Units .................................................................................................................................. 70 14.1 Introduction ............................................................................................................................................................................ 70 14.2 Controls, connectors and indicators ............................................................................................................................... 70 14.3 Internal settings .................................................................................................................................................................... 74 14.4 Modes ..................................................................................................................................................................................... 76 14.5 Installation .............................................................................................................................................................................. 78 14.6 Subscription .......................................................................................................................................................................... 80 14.7 External connections ........................................................................................................................................................... 82 14.8 Operation ............................................................................................................................................................................... 83 15. DCN-MICL, DCN-MICS Pluggable Microphones ................................................................................................................ 85 15.1 Introduction ............................................................................................................................................................................ 85 15.2 Controls, connectors and indicators ............................................................................................................................... 85 15.3 External connections ........................................................................................................................................................... 86 15.4 Operation ............................................................................................................................................................................... 86 16. DCN-WLIION Battery Pack ...................................................................................................................................................... 87 16.1 Introduction ............................................................................................................................................................................ 87 16.2 Safety ...................................................................................................................................................................................... 87 16.3 Controls, connectors and indicators ............................................................................................................................... 88 Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Table of Contents en | 9 16.4 Installation .............................................................................................................................................................................. 88 16.5 Operation ............................................................................................................................................................................... 88 17. DCN-WCH05 Battery Charger ................................................................................................................................................ 89 17.1 Introduction ............................................................................................................................................................................ 89 17.2 Controls, connectors and indicators ............................................................................................................................... 89 17.3 Installation .............................................................................................................................................................................. 90 17.4 External connections ........................................................................................................................................................... 91 17.5 Operation ............................................................................................................................................................................... 92 18. DCN-WPS Power Supply Adapter ......................................................................................................................................... 93 18.1 Introduction ............................................................................................................................................................................ 93 18.2 Installation .............................................................................................................................................................................. 93 18.3 External connections ........................................................................................................................................................... 93 19. DCN-FCWD10 Flight Case for Wireless Discussion Units .............................................................................................. 94 20. DCN-WFCCU Flight Case for DCN-WCCU and DCN-WAP .......................................................................................... 94 21. DDCN-RCWD10 Roller Case for 10 Wireless Discussion .............................................................................................. 95 Section 4 - Appendices ............................................................................................................................................. 97 A Audio levels ................................................................................................................................................................................... 98 B Product index ..............................................................................................................................................................................100 C Statements for FCC & Industry Canada ..............................................................................................................................102 D Declarations ................................................................................................................................................................................103 Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Table of Contents Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 10 DCN Wireless | Installation and User Instructions | System Design and Planning Section 1 - System Design and Planning Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 11 DCN Wireless | Installation and User Instructions | System Design and Planning Wireless network design 1.1 Introduction The DCN Wireless has three parts: the wireless network, the DCN and the optical network. This chapter tells how to design the wireless network. 1.2 en | 12 Wireless discussion units that have software version 2.35 or higher have improved signaling and behavior with respect to subscription and connection, which is more in line with the wired DCN units (refer to section 14.6). The difference in signaling can be used to detect the software version of the unit. This can be 2.35, or a higher or lower version. Limits Limit 1: Control capacity The maximum number of devices in the wireless network that the central control unit can control is 150. Limit 2: Coverage area For a good operation of the wireless part, all wireless discussion units need to be in range of the wireless access point. The wireless access point has a typical maximum coverage area of 30 m by 30 m. To determine the exact coverage area the coverage test kit can be used. Note You can change the power value of the wireless access point (refer to section 11.6.4). Limit 3: Frequency The wireless network must operate in a different frequency band than adjacent wireless (computer) networks (refer to section 1.3). Limit 4: Language Distribution enabled or disabled If all wireless discussion units have software version 2.35 or higher, language distribution in the wireless network can either be enabled or disabled. This system setting will affect all units. Note Wireless discussion units that have a software version lower than 2.35 will only work when language distribution is disabled. For information on how to enable or disable language distribution in the wireless network, refer to section 10.6.11. Bosch Security Systems | 2007-11 | 9922 141 70691 en If the wireless discussion unit has an integrated channel selector, the software version is shown on the channel selector display when: • the unit is switched on but is not subscribed to a wireless network (refer to section 14.6 for information on subscription). • the unit is in programming mode (refer to section 14.3.1). For information on how to enable or disable language distribution in the wireless network, refer to section 10.6.11. Limit 5: Number of Language Distribution Channels The wireless network has a maximum of 10 language distribution channels, excluding the channel for the floor. The total number of language distribution channels in the system, is set via the interpreter desk (refer to section 33.6.6.4 in the DCN Next Generation Installation & User Instructions). If there are more than 10 Language Distribution Channels, only the first 10 channels will be available for the wireless network. All higher channels will only be available for the (wired) DCN network and/or the infrared Integrus network. DCN Wireless | Installation and User Instructions | System Design and Planning 1.3 Frequency band 1.3.1 802.11g specification The wireless network is based on the 802.11g specification for WiFi technology. Devices that comply to the 802.11g specification operate in frequency bands between 2.4000 and 2.4835 GHz. Note Although the system operates on frequencies which are license free world wide, you must be aware of country specific limitations and follow them. 1.3.2 Wireless computer networks Wireless (computer) networks can also be based on the 802.11g specification for WiFi technology. In the wireless computer networks, 13 overlapping channels are available (refer to figure 1.1). 1.3.3 Carriers In the wireless network of DCN Wireless, three non-overlapping wireless carriers are available (refer to figure 1.2). 1.3.4 Interference The wireless network of DCN Wireless can cause interference on wireless computer networks. You must make sure the DCN wireless carrier does not overlap the WLAN channel. Refer to figure 1.3. In the example, the WLAN channel is 3. WLAN channel 3 overlaps DCN wireless carriers 0 and 1. Therefore, use DCN wireless carrier 2. Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 13 2.467 2.472 2.484 GHz 2.422 2.427 2.432 2.437 2.442 2.447 2.452 2.457 2.462 2.467 2.472 2.484 GHz figure 1.3: Example of interference Bosch Security Systems | 2007-11 | 9922 141 70691 en 10 11 12 13 2.462 2.457 2.452 2.447 2.442 2.437 2.432 2.427 2.422 2.417 2.417 2.412 2.400 GHz 2.412 figure 1.2: DCN wireless carriers 2.400 GHz 2.422 2.427 2.432 2.437 2.442 2.447 2.452 2.457 2.462 10 11 13 2.484 GHz 2.472 2.467 2.417 12 2.412 2.400 GHz DCN Wireless | Installation and User Instructions | System Design and Planning en | 14 figure 1.1: WLAN channels DCN Wireless | Installation and User Instructions | System Design and Planning DCN design 2.1 Introduction The DCN Wireless has three parts: the wireless network, the DCN, and the optical network. This chapter tells how to design the DCN. 2.2 Limits For the DCN limits, refer to chapter 1 in the “DCN Next Generation, Installation & User Instructions”. The DCN-WCCU has the same limitations with the following deviations. Make sure the following limits are not exceeded when you design the DCN: Limit 1: Control capacity The DCN-WCCU wireless central control unit can control a maximum of 95 active wired devices. The number of passive devices is without limit. The following wired active devices can be connected in any combination: • DCN-DIS Discussion Units • DCN-CON Concentus Delegate Units • DCN-DDI Dual Delegate Interface • DCN-IDESK Interpreter Desks • DCN-DDB Data Distribution Board • DCN-FVU Voting Unit The connected wired active devices have the same limitations as the wireless devices with respect to the number of audio channels (refer to section 12.4.1). Limit 2: Single CCU only The DCN-WCCU Wireless Central Control Unit cannot be used in a multi CCU system. Limit 3: Software Packages Only use the following software packages in combination with the DCN-WCCU Wireless Central Control Unit: • LBB4162/00 Standalone Automatic Camera Control Software • LBB4187/00 Open Interface Software • DCN-SWSMV Synoptic Microphone & Voting Control Software Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 15 DCN Wireless | Installation and User Instructions | System Design and Planning 3.1 Optical network design 3.4 Introduction Each device in the optical network has a number of nodes (refer to table 3.1). The maximum number of nodes in the optical network is 63. The DCN Wireless has three parts: the wireless network, the DCN and the optical network. This chapter tells how to design the optical network. 3.2 Calculation tool The calculation tool makes the planning and design of the optical network easier. You can find the calculation tool on the CD-ROM that is supplied with your system. 3.3 en | 16 Limits Make sure that these limits are not exceeded when you make the optical network: Limit 1: Control capacity The maximum number of nodes in the optical network is 63 (refer to section 3.4). Limit 2: Number of devices The maximum number of devices that you can connect to the optical network of the central control unit is 16. The maximum number of DCN-WAP Wireless Access Points in the optical network is 1. table 3.1: Nodes Device DCN-CCU DCN-WAP LBB4402/00 LBB4404/00 LBB4410/00 LBB4414/10 INT-TX04 INT-TX08 INT-TX16 INT-TX32 PRS-4DEX4 Limit 4: Cables Refer to section 3.6: • The maximum length of a POF cable is 50 m. • The maximum cable length (POF and GOF) of the optical network is dependent on the number of nodes in the optical network. • The minimum bend radius of a 90 degree bend in a POF cable is 110 mm. • The minimum coiling radius of a POF cable is 110 mm. Bosch Security Systems | 2007-11 | 9922 141 70691 en Nodes 3.5 Power capacity 3.5.1 Introduction Each device uses power and most devices do not have an independent power supply. 3.5.2 Limit 3: Power capacity The maximum power that the optical network sockets of the central control unit can supply is 65 W (refer to section 3.5). Control capacity Power consumption The table shows the power each device in the optical network uses. table 3.2: Power consumption Device Watt DCN-WAP LBB4402/00 7.6 LBB4404/00 10.5 LBB4410/00 3.9 LBB4414/10 4.6 PRS-4DEX4 6.0 Note The Integrus transmitters do not use power from the system. DCN Wireless | Installation and User Instructions | System Design and Planning 3.5.3 Power supply 3.5.4 The CCU supplies power for: • the optical network, and • the units connected via the DCN cables. Refer to figure 3.1. Overload indication Each optical network socket of the central control unit has a red LED that comes on to show that there is a power overload. An overload occurs when the necessary power for the devices is greater than that supplied. The sockets are deactivated and the devices connected to the central control unit do not operate. The socket checks every 8 seconds for power overloads. DCN-WCCU RS 232 en | 17 Port 1 Mains RS 232 Network Port 2 Audio In 1 Audio Out 1 Audio In 2 Audio Out 2 Trunk 230 Fault OK Fault 115: 100-120V 230: 220-240V 50-60Hz 50-60Hz T2.5A 250V T2A H 250V Note If only one of the optical network sockets has a power overload, the two overload LEDs come on. P < 65 W DCN-WCCU RS 232 Port 1 RS 232 Port 2 Mains Network Audio In 1 Audio Out 1 Audio In 2 Audio Out 2 Trunk 230 Fault OK 3.6 Cabling 3.6.1 Introduction Fault 115: 100-120V 230: 220-240V 50-60Hz 50-60Hz T2.5A 250V T2A H 250V P < 65 W Many devices in the optical network have two optical network sockets that are interchangeable. You can use the two optical network sockets to make a redundant ring. DCN-WCCU RS 232 Port 1 RS 232 Port 2 Mains Network Audio In 1 Audio Out 1 Audio In 2 3.6.2 Audio Out 2 Trunk 230 Fault OK Definitions Fault 115: 100-120V 230: 220-240V 50-60Hz 50-60Hz T2.5A 250V T2A H 250V P < 130 W figure 3.1: Optical network power supply If more power is necessary, you must install external power supplies in the optical network. The devices below can connect to external power supplies: • LBB4410/00 Network Splitter (refer to the DCN Next Generation Installation and User Instructions). • LBB4414/10 Fiber Interface (refer to the DCN Next Generation Installation and User Instruction). Bosch Security Systems | 2007-11 | 9922 141 70691 en The optical network uses two types of cable: • POF Plastic Optical Fiber. • GOF Glass Optical Fiber. DCN Wireless | Installation and User Instructions | System Design and Planning 3.6.3 Optical fiber length 3.6.5 Because of optical attenuation, the maximum length of optical network cables (LBB4416) is 50 m. You can use GOF and fiber interfaces to increase the distance between devices to a maximum of 1500 m. Note If the distance between two devices is less than 100 m, use a network splitter between devices to remove the use of fiber interfaces. Use only the trunk sockets of the network splitter in this case. 3.6.4 Cable couplers You can use the LBB4419/00 Cable Couplers to connect optical network cables to each other. A cable coupler causes optical attenuation. Each cable coupler decreases the maximum distance between two devices in the optical network (normally 50 meters) with 20 meters. en | 18 Maximum cable length The maximum cable length (LBB4416 and GOF) of the optical network is dependent on: • The number of nodes • The number of LBB4414/10 Fiber Interfaces Do as follows: 1 Find the number of nodes of each device from the node value table (refer to table 3.1). Add together the nodes of all devices. 2 With the value of step 1, use the graph (refer to figure 3.2) to find the maximum cable length without LBB4414/10 Fiber Interfaces. 3 Count the number of LBB4414/10 Fiber Interfaces. Each fiber interface decreases the maximum cable length from step 2 with 18 m. 2150 2050 1950 1850 Max. cable length (m) 1750 1650 1550 1450 1350 1250 1150 1050 950 10 15 20 25 30 Nodes figure 3.2: Cable correction graph Bosch Security Systems | 2007-11 | 9922 141 70691 en 35 40 45 50 55 60 63 DCN Wireless | Installation and User Instructions | System Design and Planning 3.6.6 Bending The minimum bend radius of a 90 degree bend in an LBB4416 cable is 110 mm (refer to figure 3.3). A 180 degree bend is the same as two 90 degree bends. R=110 mm figure 3.3: Bend radius 3.6.7 Coiling The minimum coiling radius of an LBB4416 cable is 110 mm (refer to figure 3.4). R=110 mm figure 3.4: Coiling radius 3.7 Example layouts 3.7.1 Introduction The number and type of devices that make the optical network give the layout of the optical network. This chapter shows examples of the possible layouts of optical networks. Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 19 DCN Wireless | Installation and User Instructions | System Design and Planning 3.7.2 Basic optical network 3.7.4 Refer to figure 3.5 for an example of a basic optical network. DCN-WCCU en | 20 Redundant cables The example of the extended optical network (refer to figure 3.6) has no redundant cable. If the cable between the central control unit (DCN-WCCU) and the wireless access point (DCN-WAP) breaks, the central control unit cannot transmit data to the wireless access point. A solution for this problem is to use redundant cable (refer to figure 3.7 for an example). DCN-WCCU DCN-WAP LBB4404/00 DCN-WAP PRS-4DEX4 figure 3.5: Basic optical network 3.7.3 Extended optical network INT-TX Refer to figure 3.6 for an example of an extended optical network. figure 3.7: Redundant optical network DCN-WCCU LBB4404/00 DCN-WAP The example of the system without redundant cable (refer to figure 3.6) has no connection between the cobranet interface (LBB4404/00) and the central control unit (DCN-WCCU). The example of the system with redundant cable has a connection between the Cobranet Interface and the central control unit. This connection makes a ring. If a cable breaks, the optical network continues to operate. The total power of all devices in the redundant optical network is 65 W. If the optical network is defective near the central control unit, the other socket can supply power to all of the optical network. PRS-4DEX4 INT-TX figure 3.6: Extended optical network Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | System Design and Planning 3.7.5 Tap-offs The network splitter (LBB4410/00) lets you make tap-offs (refer to figure 3.8 for an example). Tap-offs cannot be redundant. If the cable between the network splitter and the digital audio expander (PRS-4DEX4) becomes defective, the digital audio expander has no connection to the central control unit. DCN-WCCU DCN-WAP LBB4410/00 PRS-4DEX4 INT-TX figure 3.8: Redundant optical network with tap-off Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 21 DCN Wireless | Installation and User Instructions | System Design and Planning Camera control en | 22 Infra-red wireless language distribution 4.1 Introduction The central control unit can automatically point video cameras in the direction of the delegate or chairman who speaks. You can connect video cameras to the central control unit through a video switcher or directly to the central control unit. Use a video switcher to connect more that one video camera and video display to the central control unit. 4.2 You can connect the system to an Integrus digital infra-red language distribution system. This system has a transmitter, radiators and receivers. Note Refer to the Integrus Installation and User Instructions for more data. Scenarios These scenarios are possible: • Direct camera control in a system without a DCN control PC. Refer to the DCN Next Generation Installation and User Instructions. • Camera control through a video switcher in a system without a DCN control PC. Refer to the DCN Next Generation Installation and User Instructions. figure 5.1: Integrus Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | System Design and Planning CobraNet CobraNet is a standard for the transport of real-time digital audio and control data through an Ethernet network. A CobraNet network can transport a maximum of 64 channels of 48 kHz, 20-bit audio through a 100 Mbit link connection in each direction. Many manufacturers of professional audio devices support the CobraNet standard. The DCN Wireless digital congress network can connect to CobraNet networks with the LBB4404/00 Cobranet Interface. For example, you can use the LBB4404/00 Cobranet Interface to: • Benefit from Ethernet infrastructure • Transport audio signals over large distances Note Refer to the DCN Next Generation Installation and User Instructions for the LBB4404/00 Cobranet Interface. PC data, for example data from the DCN Wireless Central Control Unit can co-exist with CobraNet data on the same Ethernet network when you use managed Ethernet switches that are approved by Peak Audio. Note Refer to the website of Peak Audio (www.peakaudio.com) for: • More data about CobraNet networks. • A list of approved Ethernet switches. Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 23 User set-up 7.1 Public areas and walkways Keep public areas clear of system and extension cables and connections. 7.2 Headphones/headsets Connect headphones or headsets to: • the Wireless discussion units. • the Interpreter desks. • the Channel selector. • the Integrus receivers. Acoustic feedback between the connected headphones or headsets and the microphone occurs when: • The volume level is set too high. • The headphones are too close to the activated microphones (refer to section 8.7). 7.3 Speaking distance The recommended speaking distance from the microphone is 0.2 m to 0.4 m. 7.4 Interpreter booths Make sure each interpreter booth has sufficient dimensions. The International Organization for Standardization (ISO) gives the specification for interpreter booths. Refer to standard ISO 2603 ‘Booths for simultaneous interpretation - General characteristics and equipment’ for more data. DCN Wireless | Installation and User Instructions | System Design and Planning Device set-up 8.1 General Caution Do not put objects on top of devices. Objects can fall through the airflow holes. A blockage of the airflow holes can cause a risk of fire. 8.4 • • • Make sure that the area is clean. Make sure that the air is sufficiently cool. Make sure that there is sufficient lighting. 8.2 Cables Use different cable ducts for the extension and mains cables. Identify each cable with a label and divide trunks to manageable geographic locations. In public areas where people can touch or move above the connectors and cables, use metal protection covers. Refer to the applicable protection specification of the protection covers. 8.3 Temperature When devices are in a 19-inch rack, make sure there is rack space between the devices to let sufficient air flow. Forced airflow may be necessary to keep the temperature of the devices below the maximum temperature (refer to section 9.2). This extends the lifetime of the devices. Bosch Security Systems | 2007-11 | 9922 141 70691 en Ventilation Keep a good airflow. Airflow holes are in the front, right and left sides of all 19-inch devices (for example, the central control unit and the audio expander). • Put the devices on a hard and level surface. • Put the central control unit at minimum distance of 0.10 m from walls to let sufficient air flow. 8.5 Cleaning Caution Do not use alcohol, ammonia or petroleum solvents or abrasive cleaners to clean the devices. Caution Do not put the devices near or above a radiator, heat grill or in direct sunlight. Caution Do not cause vibration of the devices. en | 24 1 Disconnect the mains power supply from the devices, if you want to clean the devices. 2 Use a soft cloth that is not fully moist with a weak soap and water solution. 3 Let the device fully dry before you operate the device again. 8.6 Storage Note If the central control unit is stopped or disconnected from the mains power supply for more than 100 days, the values of all system parameter are erased. This includes all the values of the parameters of the interpreter desks and the wireless access point. This does not include the subscription list. 1 Disconnect the mains power supply from the devices, if you do not use the devices for a long time. 2 Keep the devices in a clean and dry area with a sufficient airflow. 3 Remove the batteries of the wireless discussion units. DCN Wireless | Installation and User Instructions | System Design and Planning 8.7 en | 25 Acoustic feedback Acoustic feedback (‘howling’) occurs when the sound of the loudspeakers or headphones in the system is sent to the system again by activated microphones. table 8.1: Acoustic feedback Source The acoustic feedback is caused by the loudspeakers of the contribution devices. Quick solution Decrease the volume level of the system. For example, with the knob on the front of the central control unit (refer to section 10.6.3). Structural solution Do as follows: 1 Install a feedback suppressor between audio input 2 and audio output 2 of the central control unit. 2 Set the audio routing mode of the system to Insertion (refer to section 12.6). The acoustic feedback is caused by an external public address system that is connected to the DCN Wireless digital congress network. Decrease the volume level of the public address system or the DCN Wireless digital congress network. Install a feedback suppressor between audio output 1 and the input of the external public address system. The acoustic feedback is caused by the headphones that are connected to the contribution devices. Tell the chairmen and the delegates to decrease the volume level of their headphones with their contribution devices. Install and configure the headphones level reduction of the contribution devices. (Refer to the section about the contribution devices.) Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | System Design and Planning Technical data 9.1 System electrical and electro-acoustic characteristics 9.1.1 General en | 26 table 9.1: Electro-acoustic characteristics Nominal input level: 85 dB SPL Maximum input level: 110 dB SPL Automatic gain reduction (not for PA-floor output): • 24 dB (interpretation channels) • 12 dB (delegate loudspeaker channel) Automatic gain reduction with: • 3 dB (2 microphones on) • 6 dB (4 or more microphones on) Loudspeaker volume control: 24 steps of 1 dB and off (mute) 9.1.2 • • • Routing links From delegate microphone to interpreter headphones From delegate microphone to delegate headphones From interpreter microphone to delegate headphones table 9.2: Transmission links Frequency response: • 125 Hz to 20 kHz (General) • 125 Hz to 3.5 kHz (Intercom links) Harmonic distortion: < 0.5% Harmonic distortion @ overload: < 1% Crosstalk attenuation @ 4 kHz: > 80 dB Dynamic range: > 90 dB Bosch Security Systems | 2007-11 | 9922 141 70691 en • • • • • From interpreter microphone to interpreter headphones From auxiliary input to delegate headphones From auxiliary input to interpreter headphones From delegate microphone to auxiliary output From interpreter microphone to auxiliary output DCN Wireless | Installation and User Instructions | System Design and Planning 9.1.3 • • • Combined devices from input to output Delegate microphone with transmission link to interpreter headphones Delegate microphone with transmission link to delegate headphones Delegate microphone with transmission link to auxiliary output • • • Interpreter microphone with transmission link to interpreter headphones Interpreter microphone with transmission link to delegate headphones Interpreter microphone with transmission link to auxiliary output table 9.3: Combined devices from input to output Typical frequency response: 125 Hz to 20 kHz Front-to-random sensitivity index: > 4.6 dB Rated equivalent sound pressure level due to inherent noise: < 25 dB(A) Total harmonic distortion @ overload: < 1% Crosstalk attenuation: > 80 dB 9.2 Environmental conditions table 9.4: Environmental conditions Working conditions: Fixed, stationary, transportable Temperature range: • -20 to +70 °C (transport) • +5 to +45 °C (operation) • For EPS and contribution devices with an LCD, the maximum temperature is +40 °C. Relative humidity: < 95% 9.3 Safety According Low-Voltage Directive (LVD) 2006/95/EC. • For European countries: according EN60065. Marking: CE • For international countries: IEC 60065 according CB-Scheme. • For North America: • USA: ANSI/UL 60065 • Canada: CAN/CSA no. 60065 • Marking c-CSA-us. Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 27 DCN Wireless | Installation and User Instructions | System Design and Planning 9.4 en | 28 Electro-magnetic compatibility table 9.5: Electromagnetic compatibility EMC compatibility: According EMC Directive 2004/108/EC European approvals: CE marking EMC environment: for commercial or professional use EMC emission: According harmonized standard EN 55103-1 (E3) (prof. audio/video equipment) According FCC rules (FCC part 15) complying to limits for class A digital devices EMC immunity: According harmonized standard EN 55103-2 (E3) (prof. audio/video equipment) 9.5 Wireless devices table 9.6: Wireless devices Frequency 2400 - 2483.5 MHz Max. transmitting power: 100 mW e.i.r.p. Bandwidth: 22 MHz Leading listed and certified country approvals: Europe CE Standard USA Standard Canada Standard Japan Standard Bosch Security Systems | 2007-11 | 9922 141 70691 en Telecom EMC Safety Telecom, EMC Safety Telecom, EMC Safety Telecom, EMC EN 300 328 EN 301 489-1 EN 301 489-17 EN 60950-1 FCC part 15.247 ANSI / UL 60950-1 RSS 210 CSA 22.2 no. 60950-1 Ordinance regulating radio equipment: Item 19 Article 2 DCN Wireless | Installation and User Instructions | System Design and Planning 9.6 Miscellaneous table 9.7: Miscellaneous Basic standard ESD: According EN 61000-4-2. Contact discharge: 4 kV and air discharge: 8 kV Basic standard mains harmonics and voltage fluctuations, flicker: According EN 61000-3-2 and EN 61000-3-3 Basic standard RF electromagnetic fields: According EN 61000-4-3 RF conducted: 150 kHz - 80 MHz: 3 Vrms RF radiated 80 - 1000 MHz: 3 V/m Cellular telephone (GSM) dummy test: at 20 cm speech distance Criteria: not effecting normal operation. Magnetic immunity: Rack mounting: 50 Hz - 10 kHz: 4 - 0.4 A/m No rack mounting: 50 Hz - 10 kHz: 3 - 0.03 A/m Basic standard low energy electrical fast transients, bursts: According EN 61000-4-4 Mains: fast transients: 1 kV; signal and control data lines: 0.5 kV Basic standard high energy surges: According EN 61000-4-5 Mains: surges: 1 kV CM and 0.5 kV DM. Basic standard voltage dips, short interruptions, variations: According EN 61000-4-11 Mains: voltage dips 100% for 1 period, 60% for 5 periods, > 95% for 5 seconds. Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 29 DCN Wireless | Installation and User Instructions | System Design and Planning Intentionally left blank. Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 30 DCN Wireless | Installation and User Instructions | Central Devices Section 2 - Central Devices Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 31 DCN Wireless | Installation and User Instructions | Central Devices 10 DCN-WCCU Wireless 10.2 Central Control Unit en | 32 Controls, connectors and indicators 10.2.1 Front view 10.1 Introduction The DCN-WCCU Wireless Central Control Unit controls the system. The central control unit can operate with or without a control PC. Note The DCN-WCCU-UL is the CSA/UL approved version of the DCN-WCCU. The front of the central control unit (refer to figure 10.1) contains: 1 On/off switch - Starts and stops the central control unit. 2 Display - Shows the configuration menu (refer to 10.6). 3 Knob - Operates the configuration menu (refer to 10.6). You can also change the volume level of the system with the knob. 4 Headphones socket - Connects headphones to the central control unit (refer to 10.5.4). C aution R is k of electric s hock. Do not open. Avis R is k of electric s hock. Do not open. RS 232 Port 1 RS 232 Port 2 Mains Network Audio In 1 Audio Out 1 Audio In 2 Audio Out 2 Trunk 230 Fault OK Fail 115: 100-120V 230: 220-240V 10 figure 10.1: Front and rear views Bosch Security Systems | 2007-11 | 9922 141 70691 en 11 12 11 12 13 50-60Hz 50-60Hz T2.5A 250V T2A H 250V 14 DCN Wireless | Installation and User Instructions | Central Devices 10.2.2 Rear view The rear of the central control unit (refer to figure 10.1) contains: 5 RS232 ports - Connects a PC, remote controllers or video cameras to the central control unit (refer to 10.5.8). 6 Power inlet - Connects the central control unit to the mains power supply with a power cable (refer to 10.5.1). 7 Ground screw - Connects the central control unit to ground. 8 Optical network sockets - Connects the central control unit to the optical network (refer to 10.5.3). 9 DCN sockets - Connect the central control unit to the DCN (refer to 10.5.2). 10 Fault contact - Connects the central control unit to devices to sense the condition of the central control unit (refer to 10.5.7). 11 Audio inputs - Connect the central control unit to external analog audio sources (refer to 10.5.5). 12 Audio outputs - Connect the central control unit to external analog audio devices (refer to 10.5.6). 13 Voltage selector - Selects the voltage on which the central control unit must operate (refer to 10.5.1). 14 Fuse holder - Prevents damage to the internal power supply unit of the central control unit (refer to 10.5.1). Bosch Security Systems | 2007-11 | 9922 141 70691 en 10.3 en | 33 Internal settings 10.3.1 Overview Warning Before you open the central control unit, disconnect it from the mains power supply. Electrical discharges from the mains power supply can kill you. Caution Before you open the central control unit, take measures to prevent electro-static discharges. The PCBs of the central control unit (refer to figure 10.2) contain: 15 Software LEDs - Show the condition of the software of the central control unit. When the software runs correctly, the yellow and green LEDs flash. 16 S600 switches - Reserved (refer to 10.3.2). 17 X605 jumper block - Enables or disables the watchdog (refer to 10.3.5). 18 Reset switch - Starts the central control unit again. 19 Optical network processor indicator - Comes on when the optical network processor operates correctly. 20 S500 switches - Configure the RS232 ports of the central control unit (refer to 10.3.3). 21 X600 jumper block - Connects and disconnects the internal back-up battery of the central control unit (refer to 10.3.4). 22 X104 jumper block - Connects and disconnects the mechanical ground and the electrical ground (refer to 10.3.6). 23 Fuse - Prevents damage to the electronic components in the central control unit. DCN Wireless | Installation and User Instructions | Central Devices 18 en | 34 15 17 16 S600 ON S601 B601 B602 B604 X14 X605 X600 X103 G600 B1000 X1001 T1 R1 P1 N1 M1 L1 K1 J1 H1 G1 F1 E1 D1 C1 B1 A1 T2 R2 P2 N2 M2 L2 K2 J2 H2 G2 F2 E2 D2 C2 B2 A2 T3 T4 T5 T6 T7 T8 T9 T10 R3 R4 R5 R6 R7 R8 R9 R10 P3 P4 P5 P6 P7 P8 P9 P10 N3 N4 N5 N6 N7 M3 L3 K3 J3 H3 M4 L4 K4 J4 H4 M5 L5 K5 J5 H5 J6 H6 M6 L6 M7 L7 K6 K7 H7 G3 F3 E3 G4 F4 E4 G5 F5 E5 G6 F6 G7 F7 E6 E7 N8 M8 L8 K8 J8 H8 G8 F8 E8 N9 M9 L9 K9 J9 H9 G9 F9 E9 J10 H10 N10 D3 D6 D7 D8 D9 B3 A3 C4 B4 A4 C5 C3 B5 A5 C6 B6 C7 B7 A6 A7 C8 B8 A8 C9 B9 A9 C10 B10 A10 L11 K11 J11 H11 G11 F11 E11 D11 N12 M12 L12 K12 J12 H12 G12 F12 E12 D12 C12 B12 P13 N13 M13 L13 K13 J13 H13 G13 F13 E13 D13 C13 B13 A13 R14 P14 N14 M14 L14 K14 H14 G14 F14 E14 C14 B14 A14 T15 R15 P15 N15 M15 L15 K15 J15 H15 G15 F15 E15 D15 C15 B15 A15 T16 R16 P16 N16 L16 K16 J16 H16 G16 F16 E16 D16 C16 B16 A16 G10 E10 D4 M11 P12 R13 T14 J14 F10 D5 K10 P11 R12 T13 N11 M10 D10 L10 R11 T12 T11 D14 C11 B11 F100 X1000 A11 A12 S800 S1000 ON X155 S500 X104 19 20 figure 10.2: Internal settings Bosch Security Systems | 2007-11 | 9922 141 70691 en 21 22 23 DCN Wireless | Installation and User Instructions | Central Devices en | 35 10.3.2 S600 switches table 10.1: S600 switches (* = default) Switch Position Description S600-1 ON* Reserved. Do not change the position of this switch. OFF S600-2 ON Reserved. Do not change the position of this switch. OFF* S600-3 ON Reserved. Do not change the position of this switch. OFF* S600-4 ON Reserved. Do not change the position of this switch. OFF* S600-5 ON Reserved. Do not change the position of this switch. OFF* S600-6 ON Reserved. Do not change the position of this switch. OFF* S600-7 ON Reserved. Do not change the position of this switch. OFF* S600-8 ON Boot mode. Enables the download of new firmware (in case a download failed). OFF* Normal operation. 10.3.3 RS232 configuration Use the S500 switches to configure the RS232 ports of the central control unit (refer to table 10.2 and table 10.3). table 10.2: RS232 protocol (* = default) Protocol Port 1 S500-1 Open interface Off Terminal Off Full On* Camera control On table 10.3: RS232 baudrate (* = default) Baudrate Port 1 S500-3 9.6k Off 19.2k Off 57.6k On 115.2k On* S500-2 Off On Off* On Port 2 S500-5 Off Off On On* S500-6 Off On Off On* S500-4 Off On Off On* Port 2 S500-7 Off Off* On On S500-8 Off On* Off On Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Central Devices en | 36 10.3.4 Internal back-up battery 10.3.5 Watchdog Use the X600 jumper block to connect and disconnect the internal back-up battery of the central control unit (refer to table 10.4). Use the X605 jumper to enable or disable the watchdog of the central control unit (refer to table 10.5). Note When your central control unit is new, you must energize the central control unit to charge the internal back-up battery. The internal back-up battery is fully charged after 24 hours. table 10.4: X600 jumper block (* = default) Jumper shunt Description 1 and 2 * Connects the internal back-up battery. When you stop the central control unit, the memory of the central control unit is not erased. 2 and 3 Disconnects the internal back-up battery. When you stop the central control unit, the memory of the central control unit is immediately erased. The memory of the central control unit contains: • The license code • The settings of the interpreter desks. Note You only have a license code when you use the system in combination with: • The PC Control Software • A remote controller Note The subscription list is not erased when the internal back-up battery is empty. The subscription list is stored in another location. Bosch Security Systems | 2007-11 | 9922 141 70691 en table 10.5: X605 jumper block (* = default) Jumper shunt Description Present The watchdog is disabled. The central control unit does not start again after an error. Not present* Enables the watchdog. The central control unit starts again after an error. Note When you disable the watchdog, the system can operate incorrectly. 10.3.6 Ground Use the X104 jumper block to connect and disconnect the system ground and the ground of the central control unit (refer to table 10.6). For example, you can connect the system ground and the ground of the central control unit to prevent hum. table 10.6: X104 jumper block (* = default) Jumper shunt Description 1 and 2 Connects the system ground and the ground of the central control unit. 2 and 3 * Disconnects the system ground and the ground of the central control unit. Note When you connect the system ground to the ground of more than one device in the system, you can create ground loops. Ground loops can cause hum. DCN Wireless | Installation and User Instructions | Central Devices 10.4 Installation Install the central control unit in a 19-inch rack system or on a flat surface. Four feet and two brackets are supplied with the central control unit (refer to figure 10.3). 10.5 en | 37 External connections 10.5.1 Power supply Use the following procedure to connect the central control unit to a mains power supply: Note The DCN-WCCU is configured for a voltage of 220 - 240 V(AC). The DCN-WCCU-UL is configured for a voltage of 100 - 120 V(AC). 1 Set the voltage selector on the rear of the central control unit to the correct position (refer to table 10.8). figure 10.3: Installation table 10.7: Physical characteristics Dimensions (h x w x d), flat surface: 92 x 440 x 400 mm (without brackets, with feet) Dimensions (h x w x d), 19-inch rack system: 88 x 483 x 400 mm (with brackets, without feet) Weight: 6.7 kg (without brackets, without feet) Note When you install the central control unit in a 19-inch rack system, the central control unit extends 36 mm in front of the brackets. table 10.8: Voltage selector Power supply voltage Voltage selector 90 to 132 V(AC) 115 198 to 264 V(AC) 230 2 Make sure that the fuse holder in the rear of the central control unit contains the correct fuse (refer to table 10.9). table 10.9: Fuses Voltage selector 115 230 Fuse T2.5A 250 V (UL 248) T2AH 250 V (IEC 60127) 3 Connect a locally approved power cable to the central control unit (refer to figure 10.4). figure 10.4: Power supply Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Central Devices 4 Connect the power cable to a power supply. Warning Make sure that the mains power supply is grounded. Electrical discharges from the mains power supply can kill you. en | 38 10.5.3 Optical network Connect the trunk of the optical network to the optical network sockets of the central control unit with optical network cables (refer to figure 10.6). 10.5.2 DCN Connect the trunk of the DCN to the DCN sockets of the central control unit (refer to figure 10.5). LED figure 10.6: Optical network Each optical network socket has a red LED that comes on if there is an overload (refer to figure 10.6 and 3.5.4). LED figure 10.5: DCN Each DCN socket has a red LED that comes on if there is an overload (refer to figure 10.5 and 3.5.4). table 10.10: DCN connection Number of connections: 2x DCN socket Location: Rear side Power supply: max. 65 W Bosch Security Systems | 2007-11 | 9922 141 70691 en table 10.11: Optical network connections Number of connections: 2x proprietary sockets Location: Rear side Nodes: Power supply: max. 65 W (refer to figure 3.1) DCN Wireless | Installation and User Instructions | Central Devices en | 39 10.5.4 Headphones 10.5.5 Audio inputs You can connect headphones to the headphones socket of the central control unit. The headphones must have a 3.5 mm plug (refer to figure 10.7). You can connect an external analog audio source to the audio inputs of the central control unit. The central control unit has two audio inputs. Each audio input has (refer to figure 10.8): • 1 XLR socket for balanced signals. The electric circuits behind the XLR sockets contain transformers. • 1 double cinch socket for unbalanced signals. 2 3 1 figure 10.7: 3.5 mm headphones plug, connection table 10.12: 3.5 mm headphones plug, connection Number Signal Left Common Right Note You can also connect mono headphones to the headphones socket. You can select the signal that is available on the headphones socket with the configuration menu (refer to 10.6.5). Bosch Security Systems | 2007-11 | 9922 141 70691 en Note The audio inputs change stereo signals in mono signals. Audio In figure 10.8: Audio input, connection table 10.13: Audio input, connection Pin Type Signal Description XLR Xternal Shield/ground Live Positive Return Negative Cinch Live Signal in Return Shield/ground DCN Wireless | Installation and User Instructions | Central Devices You can select the procedure that is used to send audio signals through the central control unit with the audio routing modes (refer to 10.6.8). Note You can only connect line level sources to the audio inputs of the central control unit. It is not possible to connect microphone level sources. table 10.14: Audio input details, line level signals Number of connections: • 1x XLR socket for each audio input • 1x double cinch socket for each audio input Location: Rear side Cable: Shielded cable Maximum level: Refer to appendix A Nominal level: Refer to appendix A Frequency response: -3 dB @ 30 Hz and 20 kHz Impedance: • XLR: 22 kΩ • Cinch: 12 kΩ Signal-to-noise ratio: > 85 dBA @ max. level CMRR: > 60 dB @ 100 Hz > 50 dB @ 1 kHz Crosstalk attenuation: > 85 dB @ max. level Distortion: < 0.1% @ 100 Hz @ -3 dB of the max. input Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 40 10.5.6 Audio outputs You can connect an audio recording device or a public address system to the audio outputs of the central control unit. The central control unit has two audio outputs. Each audio output has (refer to figure 10.9): • 1 XLR plug for balanced signals. The electric circuits behind the XLR plugs contain transformers. • 1 double cinch socket for unbalanced signals. Note The two cinch sockets contain the same mono signal. Audio Out figure 10.9: Audio output, connection table 10.15: Audio output, connection Pin Type Signal Description XLR Xternal Shield/ground Live Positive Return Negative Cinch Live Signal out Return Shield/Ground DCN Wireless | Installation and User Instructions | Central Devices You can select the procedure that is used to send audio signals through the central control unit with the available audio routing modes (refer to 10.6.8). table 10.16: Audio output details Number of connections: • 1x XLR plug for each audio output • 1x double cinch socket for each audio output Location: Rear side Cable: Shielded cable Maximum level: Refer to appendix A Nominal level (audio output 1): Refer to appendix A Nominal level (audio output 2): Refer to appendix A Frequency response: -3 dB @ 30 Hz and 20 kHz Impedance: < 100 Ω Signal-to-noise ratio: > 89 dBA @ max. level Crosstalk attenuation: > 85 dB @ max. level Distortion: < 0.1% @ 100 Hz @ - 3 dB of the max. input Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 41 10.5.7 Fault contact Use the fault contact to send the condition of the central control unit to external devices. If the central control unit operates correctly, the OK pins are internally connected. The central control unit internally connects the Fail pins when: • The central control unit is set to off. • The internal power supply unit operates incorrectly. • The central control unit does a reset. OK Fail figure 10.10: Fault contact table 10.17: Fault contact Number of connections: 4-pole plug Location: Rear side Signal: Potential-free change-over relay Voltage: Max. 24 V(DC), 15 V(AC) Current: Max. 500 mA DCN Wireless | Installation and User Instructions | Central Devices 10.5.8 RS232 ports You can connect a PC, remote controllers or video cameras to the RS232 ports of the central control unit (refer to the DCN Next Generation Installation and User Instructions). The central control unit has 2 RS232 ports (refer to figure 10.11). You can set the protocol and the baudrate of the RS232 ports with the S500 switches (refer to 10.3.3). 9 6 figure 10.11: RS232 port, connection table 10.18: RS232 port, connection Pin Definition Description DCD Data Carrier Select RxD Receive Data TxD Transmit Data DTR Data Terminal Ready SG Signal Ground DSR Data Set Ready RTS Request To Send CTS Clear To Send RI Ring Indicator table 10.19: RS232 ports Number of connections: 2x 9-pole SUB-D socket Location: Rear side Maximum cable length: 9600 baud: 15 m, >9600 baud: 3 m Signal levels: EIA RS232-C interface specifications Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 42 DCN Wireless | Installation and User Instructions | Central Devices 10.6 en | 43 Configuration menu 10.6.1 Overview Use the configuration menu of the central control unit to configure the central control unit and the system (refer to figure 10.12). Main Menu item Menu item with sub-menu Fault status 2A Source/ Volume Monitoring 3B WAP 4O Del. Display 3Ba Serial Number 4N Defaults 3Bb HW Version 3A CCU Enquiry 3Bc FPGA Version 3Aa Serial Number 4M Unit Name 4L De-init 3Bd SW Version 4K Wireless 3Ab HW Version 4Ka Auto mic off 3Ac FPGA Version 4Kb System ID 3Ad SW Version 4J 3Ae FW Version Floor Distr. 4H Request LED 4G Mic. Priority 4E Routing I/O2 4D Level 4C Mic. Mode 4B Loudspkr 4A Setup Back 4Ba Bass Wireless Mode 4Bb Treble figure 10.12: Configuration menu Bosch Security Systems | 2007-11 | 9922 141 70691 en 4Kc Repetition 4Ja Assign Operator 4I 4F Att. Tones Intercom 4Jb Assign Chairman 4Kd WAP 4Ke Lang. Distr. DCN Wireless | Installation and User Instructions | Central Devices 10.6.2 Navigation and operation 10.6.2.1 Menu items The configuration menu consists of menu items. Refer to figure 10.13 for the parts of a menu item. Main menu number Sub-menu character Value Menu item title Parameter VU meter en | 44 10.6.2.6 To open the main menu To open the main menu, push the knob in the Main menu item. The main menu number and the menu item title flash. 10.6.2.7 To go through the main menu • Turn the knob clockwise in the main menu to go to the next menu item in the main menu. • Turn the knob counterclockwise in the main menu to go to the previous menu item in the main menu. 10.6.2.8 To open a sub-menu When the display shows a menu item that has three dots (...), the menu item gives access to a sub-menu. To open the sub-menu, push the knob in a menu item that has three dots. (The last sub-menu character and the menu item title flash.) figure 10.13: Menu item parts 10.6.2.2 Number and characters Identify menu items by the main menu number sub-menu character. The number identifies the main menu to which the menu item is connected. The characters identify the sub-menus to which the menu item is connected. 10.6.2.3 Menu title Each menu item has a title. The title gives a short description of the function of the menu item. 10.6.2.4 Parameters and values Most menu items have one or more parameters. To make adjustments, change the values of the parameters. 10.6.2.5 VU meter Some menu items have a VU meter. The VU meter shows the volume levels of signals. The VU meter has seven rows. table 10.20: VU meter VU meter One row on Seven rows on Triangle Minus Description No signal Maximum signal Clipped signal Muted by control input Bosch Security Systems | 2007-11 | 9922 141 70691 en Note To open the Setup sub-menu, you must push and hold the knob for more than 3 seconds. 10.6.2.9 To select menu items in a sub-menu • Turn the knob clockwise in a sub-menu to go to the next menu item in the sub-menu. • Turn the knob counterclockwise in a sub-menu to go to the previous menu item in the sub-menu. 10.6.2.10 To open a menu item 1 Turn the knob to select the applicable menu item. 2 When the display shows the correct menu item, push the knob to open the menu item. The display shows a cursor. DCN Wireless | Installation and User Instructions | Central Devices 10.6.2.11 To select a parameter 1 Open the correct menu item (refer to 10.6.2.10). 2 Turn the knob to move the cursor to the parameter that is shown. 3 On the parameter, push the knob. The parameter flashes. 4 Turn the knob to go to the applicable parameter. 5 When the display shows the applicable parameter, push the knob to select the parameter. The display shows a cursor. en | 45 10.6.2.16 Example For an example, do as follows to select the carrier of the wireless access point: Note Make sure that when you do this example, you start from the Main menu item. 1 Push the knob to open the Main menu. 10.6.2.12 To change the value of a parameter 1 Select the applicable parameter (refer to 10.6.2.11). 2 Turn the knob to move the cursor to the value. 3 Push the knob. The value flashes. 4 Turn the knob to go to the value. 5 When the display shows the correct value, push the knob to select the value. The display shows a cursor. 10.6.2.13 To close a menu item 1 Turn the cursor to the last character that identifies the menu item. 2 Push the knob to close the menu item. The last character and the menu item title flash. 10.6.2.14 To close a sub-menu 1 Turn the cursor to go to the second last character that identifies the menu item. 2 Push the knob to close the sub-menu. The last character and the menu item title flash. 2 Turn the knob clockwise until 4 Setup ... is reached. 3 Push-and-hold the knob for 3 seconds to open the sub-menu. 4 Turn the knob clockwise until 4K Wireless is reached. 10.6.2.15 To close the main menu 1 From the main menu, turn the primary knob clockwise to go to the < Back menu item. 2 From the < Back menu item, push the knob to go to the Main menu item. 5 Push the knob to open the sub-menu.. Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Central Devices 6 Turn the knob clockwise until 4Kd WAP is reached. en | 46 To return to the main menu: 1 Turn the knob to move the cursor to the main menu number, for example 4. 7 Push the knob to open the menu item. 2 Push the knob to go back to the Main menu. 8 Turn the knob to move the cursor to the currently selected carrier, for example Carrier: 2. 3 Turn the knob clockwise until < Back is reached. 9 Push the knob to select the carrier. The carrier number will start to flash. 4 Push the knob to go back to the main screen. 10 Turn the knob to change the carrier, for example Carrier: 1. 11 Push the knob to select the carrier. Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Central Devices en | 47 10.6.3 Main 10.6.4 Fault status When you start the central control unit, the display first shows Starting. The display then shows the Main menu item: Use the 1 Fault Status menu item to see the condition messages of the central control unit. If there is more than one message, the display shows the most important message (refer to table 10.21). The Main menu item contains: • An indicator that shows the volume level of the loudspeakers of the contribution devices. Turn the knob to change the volume level (refer to 12.6). • The name of the central control unit. The default name is CCU. You can change the name with the 4M Unit Name menu item (refer to 10.6.8). • The microphone mode and the maximum number of activated microphones. You can change the microphone mode and the maximum number of activated microphones with the 4C Mic. Mode menu item (refer to 10.6.8). Note When a PC is connected to the central control unit, the Main menu item also shows PC. Note When the condition of the central control unit changes, the Main menu item shows a message (refer to table 10.21). Such a message goes out of view when you push the knob. Note If you do not turn or push the knob for three minutes, the display automatically goes back to the Main menu item. The display does not automatically go back to the Main menu item from these menu items and their sub-menus: • 2A Source/Volume • 4Ja Assign Operator • 4Jb Assign Chairman Bosch Security Systems | 2007-11 | 9922 141 70691 en table 10.21: Messages (low to high importance) Messages Description No Fault The central control unit operates correctly. Low Battery The battery pack of a wireless device is empty within 1 hour. Bad Signal A wireless device has a bad signal reception. Incompatible SW The wireless access point has a incompatible software version. Invalid Software The central control unit cannot start. The central control unit does not contain the correct software. Downloading The central control unit downloads software. DCN Wireless | Installation and User Instructions | Central Devices en | 48 10.6.5 Monitoring Use the 2 Monitoring menu item to open the Monitoring sub-menu (refer to table 10.22). table 10.22: Monitoring sub-menu (* = default) Menu item Parameter 2A Source/Volume Signal: Floor Input 1 Input 2 Output 1 Output 2 Value Volume level: -31 to 0 dB (16 dB*) -31 to 0 dB (16 dB*) -31 to 0 dB (16 dB*) -31 to 0 dB (16 dB*) -31 to 0 dB (16 dB*) Description The signal that is available on the headphones socket of the central control unit and its volume level. 10.6.6 DCN-WCCU Enquiry Use the 3A CCU menu item to open the CCU sub-menu. The menu items in this sub-menu give general data about the central control unit (refer to table 10.23). Note This data must be mentioned in all service requests and failure reports. table 10.23: DCN-WCCU Enquiry sub-menu (* = default) Menu item Parameter Value (read-only) 3Aa Serial Nr --e.g. 20.0.00362 3Ab HW Version --- e.g. 3.0 3Ac FPGA Version --- e.g. 1.06 3Ad SW Version --- MM.mm.bbbb e.g. 2.20.1234 3Ae FW Version --- MM.mm.bbbb e.g. 4.00.1234 Bosch Security Systems | 2007-11 | 9922 141 70691 en Description The hexadecimal serial number of the central control unit. The version number of the hardware of the central control unit. The version number of the FPGA firmware of the central control unit. The version number of the software of the central control unit. • MM: Major release no. • mm: Minor release no. • bbbb: build no. The version number of the firmware of the central control unit. • MM: Major release no. • mm: Minor release no. • bbbb: build no. DCN Wireless | Installation and User Instructions | Central Devices en | 49 10.6.7 DCN-WAP Enquiry Use the 3B WAP menu item to open the WAP sub-menu. The menu items in this sub-menu give general data about the wireless access point (refer to table 10.23). Note This data must be mentioned in all service requests and failure reports. table 10.24: DCN-WAP Enquiry sub-menu (* = default) Menu item Parameter Value (read-only) 3BA Serial Nr --e.g. 1E.0.00001 3Bb HW Version --- e.g. 01.00 3Bc FPGA Version --- MM.mm.bbbb e.g. 01.00 3Bd SW Version --- MM.mm.bbbb e.g. 2.20.0055 Bosch Security Systems | 2007-11 | 9922 141 70691 en Description The hexadecimal serial number of the wireless access point. The version number of the hardware of the wireless access point. The version number of the FPGA firmware of the wireless access point. • MM: Major release no. • mm: Minor release no. • bbbb: build no. The version number of the software of the wireless access point. • MM: Major release no. • mm: Minor release no. • bbbb: build no. DCN Wireless | Installation and User Instructions | Central Devices en | 50 10.6.8 Setup Use the 4 Setup menu item to open the Setup sub-menu. You can use the menu items in this sub-menu to configure the central control unit and the system (refer to table 10.25 and table 10.26). table 10.25: Setup sub-menu (* = default) Menu item Parameter 4A Wireless Mode --- 4B Loudspkr --- Value On* Sleep Off Subscription --- 4C Mic. Mode Mode: Open* Override PTT NOM: 1, 2*, 3 1, 2*, 3 1, 2*, 3 4D Level Signal: Input 1 Input 2 Output 1 Output 2 --- Level: -6 to 6 dB (0 dB*) -6 to 6 dB (0 dB*) -24 to 6 dB (0 dB*) -24 to 6 dB (0 dB*) Mode: Recorder* Equalized PA Mix-minus Insertion Chime: Off, 1*, 2, 3 Off*, 1, 2, 3 Temporarily off* Permanently off 4E Routing I/O 2 4F Att. Tones 4G Mic. Priority Event: Priority Voting --- 4H Request LED LED setting Bosch Security Systems | 2007-11 | 9922 141 70691 en Flashing*, Continuous Description Sets the mode of the wireless network (refer to 12.3). Gives access to the Loudspkr sub-menu (refer to 10.6.9). The microphone mode of the DCN and the maximum number of activated delegate microphones (refer to 12.4). The nominal levels of the audio inputs and the audio outputs of the central control unit. The audio routing mode of the central control unit (refer to 12.6). The attention chimes of the system (refer to 12.7). The action taken by the system when the chairman releases the priority button (refer to 12.8). Sets the behaviour of the request LED for the first delegate in the request list. DCN Wireless | Installation and User Instructions | Central Devices table 10.26: Setup sub-menu (* = default) Menu item Parameter 4I Floor Distr. --- Value On*, Off 4J Intercom ... --- --- 4K Wireless --- --- 4L De-Init ... --- --- 4M Unit Name --- 4N Defaults ... --- Name: CCU* Custom name --- 4O Del. Display --- Language: English* German French Italian Dutch Spanish en | 51 Description Enables or disables floor distribution (refer to 12.9). Gives access to the Intercom sub-menu (refer to 10.6.10). Gives access to the Wireless sub-menu (refer to 10.6.11). When the wireless access point is not connected, the central control unit shows Not Available. Gives access to the De-initialization menu item (refer to 10.6.12). The name of the central control unit (max. 16 characters). Gives access to the Reset menu item (refer to 10.6.13) The language that is used by the displays of the contribution devices. Other languages (e.g. Chinese) can be downloaded to the CCU, but will overwrite the default languages. The English language cannot be overwritten. 10.6.9 Loudspkr Use the menu items in the 4B Loudspkr sub-menu to set the levels of the bass and treble output to the loudspeakers of the contribution devices (refer to table 10.27). table 10.27: Loudspkr sub-menu (* = default) Menu item Parameter 4Ba Bass --- Value -12 to 12 dB (0 dB*) 4Bb Treble -12 to 12 dB (0 dB*) --- Bosch Security Systems | 2007-11 | 9922 141 70691 en Description The level of the bass output. The level of the treble output. DCN Wireless | Installation and User Instructions | Central Devices en | 52 10.6.10 Intercom Use the menu items in the 4J Intercom sub-menu to identify the location of the chairman and the operator (refer to table 10.28 and 12.10). table 10.28: Intercom sub-menu (* = default) Menu item Parameter 4Ja Assign Operator Value No* Yes 4Jb Assign Chairman No* Yes Description Does not identify the location of the operator. Identifies the location of the operator. Does not identify the location of the chairman. Identifies the location of the chairman. 10.6.11 Wireless Use the menu items in the 4K Wireless sub-menu to configure the wireless network of the system (refer to table 10.29). table 10.29: Wireless sub-menu (* = default) Menu item Parameter 4Ka Auto mic off --- Value Enabled*, Disabled 4Kb System ID --- 0* to 15 4Kc Repetition --- 0* to 2 4Kd WAP --- Carrier: 0* to 2 4Ke Lang. Distr. Language distribution Bosch Security Systems | 2007-11 | 9922 141 70691 en Power: High* Medium Low Off Enabled, Disabled* Description Enables or disables the auto microphone off function (refer to 12.4.5). Sets the identifier of the system (refer to 11.6.2). Sets the number of repetitions of audio packets (refer to 12.5). Sets the carrier of the wireless access point (refer to 11.6.3). Sets the power of the wireless access point (refer to 11.6.4). Enables or disables language distribution in the wireless network. Refer to limits 4 and 5 in chapter 1.2 DCN Wireless | Installation and User Instructions | Central Devices en | 53 10.6.12 De-init Use the 4L De-initialize menu item in the 4L De-Init sub-menu to erase the addresses of the contribution devices and the interpretation devices (refer to table 10.30 and 12.2). table 10.30: De-init sub-menu (* = default) Menu item Parameter 4L De-init De-initialize Value None* Wired Wireless Description Does not erase the addresses. Erases the addresses of the wired devices in the DCN. Erases the subscription list of the devices in the wireless network. 10.6.13 Defaults Use the 4N Defaults sub-menu to set all parameters to the default values in the configuration menu (refer to table 10.31). This includes the values of the parameters of the interpreter desks. These parameters are not changed: • The subscription list of wireless devices • The name of the central control unit table 10.31: Defaults sub-menu (* = default) Menu item Parameter 4N Defaults Reset to defaults? Value No* Yes Description Does not put back the default values. Sets all parameters to the default values. 10.6.14 Delegate Display Use the 4O menu to select a language that is used on the display of a wired contribution device (refer to table 10.32). table 10.32: Delegate display sub-menu 4O Del. Display --- Language: English* German French Italian Dutch Spanish Bosch Security Systems | 2007-11 | 9922 141 70691 en The language that is used by the displays of the contribution devices. Other languages (e.g. Chinese) can be downloaded to the CCU, but will overwrite the default languages. The English language cannot be overwritten. DCN Wireless | Installation and User Instructions | Central Devices 11 11.1 DCN-WAP Wireless 11.3 Access Point The wireless access point contains: 1 Status LEDs - Give information about the condition of the wireless network and the wireless access point (refer to 11.7). 2 Optical network sockets - Connect the wireless access point to the optical network (refer to 11.5.1). Introduction The wireless access point: • Sends signals from the central control unit to the wireless devices. • Receives signals from the wireless devices and sends them to the central control unit. 11.2 en | 54 Controls, connectors and indicators Firmware The version numbers of the software of the wireless access point (refer to 10.6.7) and the central control unit (refer to 10.6.6) must be the same. Note Use the Download and License Tool to send new software to the wireless access point. figure 11.1: Top and bottom views Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Central Devices 11.4 Installation 11.4.1 General en | 55 11.4.2 Wall or ceiling You can use the bracket to attach the wireless access point to a wall or ceiling. Refer to figure 11.2. TORX 10 Caution Do not open the wireless access point. Any hardware change makes the product certificates invalid. Only qualified personnel can open the wireless access point. table 11.1: Physical characteristics Dimensions (h x w x d): 284.5 x 201.5 x 59 mm Weight: • DCN-WAP: 643 g (without bracket) • Bracket: 264 g 01 02 figure 11.2: Installation, wall and ceiling Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Central Devices en | 56 11.4.3 Tripod 11.4.4 Logo You can use the bracket to install the wireless access point on an LBC1259/00 Universal Floor-stand. Refer to figure 11.3. You can change the orientation of the logo. Refer to figure 11.4: TORX 10 01 01 02 figure 11.4: Installation, logo 02 figure 11.3: Installation, LBC1259/00 Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Central Devices 11.5 External connections 11.6 en | 57 Configuration 11.5.1 Optical network 11.6.1 Introduction Connect the optical network sockets of the wireless access point to the optical network with optical network cables (refer to figure 11.5). Use the configuration menu of the central control unit to configure the wireless access point. 11.6.2 System ID Note Set the correct system identity before you do the installation of the system (refer to section 12.2.2). When you change the system identity after you did the initialization, you must do the initialization again. Set the system identity with the 4Kb System ID menu item. Adjacent systems must have different system identities (refer to figure 11.6) and different carriers (refer to figure 11.7) figure 11.5: Optical network table 11.2: Optical network connections Number of connections: 2x proprietary sockets Location: Bottom side Nodes: Power consumption 4W figure 11.6: System IDs for adjacent systems Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Central Devices en | 58 11.6.3 Carrier 11.6.4 Power value Set the carrier of the wireless access point with the 4Kd WAP menu item. Adjacent systems must have different carriers (refer to figure 11.7) and different system identities (refer to figure 11.6). The wireless access point has a typical maximum coverage area of 30 m by 30 m. To determine the exact coverage area the coverage test kit can be used. The maximum coverage area of the wireless access point is dependent upon its power (refer to table 11.3). Set the power of the wireless access point with the 4Kd WAP menu item. Note If adjacent systems are using the same carrier, they must be separated by a minimum distance of 500 m. table 11.3: Power values Value High Medium Low Off Typical Coverage Area (m) 30 x 30 20 x 20 10 x 10 You can change the power value after you did the initialization of the system (refer to 12.2.2). When you decrease the power value, some wireless devices can show that they cannot find the wireless network (refer to 14.8.6). figure 11.7: Carriers for adjacent systems You can change the carrier after you did the initialization of the system (refer to 12.2.2). Note When you change the carrier during a discussion or conference, you can cause a short audio disruption. Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Central Devices 11.7 Operation The LEDs on the wireless access point give information about the condition of the wireless network and the wireless access point (refer to figure 11.8 and table 11.4). Note You can change the condition of the system with the configuration menu of the central control unit (refer to 10.6.11). A B C C B A figure 11.8: Status LEDs Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 59 DCN Wireless | Installation and User Instructions | Central Devices table 11.4: Status LEDs Blue (A) Red (B) Flashing (fast) Off Blue (C) Off Flashing (fast) Off Flashing (fast) Flashing (fast) Off On Flashing (slow) Off Flashing (fast) Flashing (slow) Off Off Flashing (fast) Off Off Off Flashing (slow) Off Off Off Off On Off Off On On Flashing (fast) Off Off Flashing (fast) On Off On On Off Off On On On Note: • Flashing (fast) = one second on, one second off. • Flashing (slow) = one sec on, three seconds off. Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 60 Description The wireless mode is set to On (refer to table 10.25), and no wireless contribution devices are connected to the system. No wireless contribution devices are connected, and menu item 3B, one of the 3B submenus, or 4Kd of the configuration menu of the central control unit is open. Use these menu items to configure the wireless access point (refer to figure 10.12). The wireless mode is set to Subscription (refer to table 10.25), and no wireless contribution devices are connected to the system. The wireless mode is set to Sleep (refer to table 10.25), and menu item 3B, one of the 3B submenus, or 4Kd of the configuration menu of the central control unit is open. Use these menu items to configure the wireless access point (refer to figure 10.12). The wireless mode is set to Sleep (refer to table 10.25). The system prepares a software transfer to the wireless access point. The wireless mode is set to Off (refer to table 10.25), or the power value of the wireless access point is set to Off (refer to table 11.3). This LED sequence is also used to indicate that the central control unit is incompatible with the wireless access point (if this is the case, a message is also shown on the display of the central control unit). The wireless access point is off. The wireless access point lost connection with the optical network. The system sends software to the wireless access point. One or more wireless contribution devices are connected to the system, and menu item 3B, one of the 3B submenus, or 4Kd of the configuration menu of the central control unit is open. Use these menu items to configure the wireless access point (refer to figure 10.12). The wireless mode is set to Subscription (refer to table 10.25), and one or more devices are connected to the system. The wireless mode is On (refer to table 10.25), and one or more wireless contribution devices are connected to the system. Internal error in wireless access point. DCN Wireless | Installation and User Instructions | Central Devices 12 System configuration 12.1 Introduction en | 61 2 Set the value of the parameter in the menu item to Wired. The addresses of all active devices in the DCN are erased. All LEDs on all active devices in the DCN come on. The central control unit controls the system. Use the configuration menu of the central control unit to configure the system. 12.2 Initialization 12.2.1 Introduction Each active DCN device in the system must have an address. The central control unit cannot send data to an active DCN device that does not have an address. During the initialization, the central control unit gives addresses to the active DCN devices. Each wireless device in the system must have a subscription. The central control unit cannot send data to a wireless device that does not have a subscription. During the initialization, the wireless access point gives subscriptions to the wireless devices. Note In the next step, you erase the subscriptions from the wireless devices and the subscription list from the wireless access point. 3 Set the value of the parameter in the menu item to Wireless. The LED around the microphone button of the wireless discussion units comes on as yellow for 2 s. 12.2.2 System You must do the initialization of the system before you can use the system: Note It is not necessary to do an initialization when the system is re-installed in another location and contains the same devices after it is re-installed. Active DCN devices hold their addresses. Wireless devices hold their subscriptions. 1 Select the 4L De-initialize menu item of the configuration menu of the central control unit. 4 Select the 4A Wireless Mode menu item of the configuration menu of the central control unit. 5 Set the value of the parameter in the menu item to Subscription. 6 Push the microphone button of each active device in the DCN. When the central control unit gives an address to an active DCN device, the LEDs of the active device go off. Note Do not push more than one microphone button at the same time. The central control unit cannot give addresses to more than one active device at the same time. Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Central Devices en | 62 7 Push the microphone button of each wireless device. When the central control unit gives a subscription to the wireless discussion unit, the LED around the microphone button comes on as green for 2 s. 12.3.4 Off 12.2.3 Extra DCN devices 12.3.5 Subscription mode You can also give addresses to active devices in the DCN after you did the initialization of the system. • Push the de-init switch of the active DCN device for less than half a second to erase the address of the active device. • Push and hold the de-init switch of the active DCN device for more than one second to erase the address and do the initialization at the same time. If the wireless mode is Subscription, the wireless network is in the subscription mode. Use the subscription mode to give subscription to extra wireless devices (refer to 12.2.4). 12.2.4 Extra wireless devices You can also give subscriptions to wireless device after you did the initialization of the system. Refer to 14.6 for instructions. 12.3 Wireless modes 12.3.1 Introduction You can set the wireless mode of the system with the 4A Wireless Mode menu item. 12.3.2 On If the wireless mode is On, the wireless network is activated. The delegates and chairman can use the wireless devices that: • Have a subscription, and • Are activated. 12.3.3 Sleep If the wireless mode is Sleep, the wireless network is in the sleep mode. Use the sleep mode to increase the time between charge of the batteries (for example, during a long break in a discussion or conference). Note The wireless devices are not deactivated in the sleep mode. Bosch Security Systems | 2007-11 | 9922 141 70691 en If you set the wireless mode to Off, the wireless network is deactivated. All wireless devices with a subscription are automatically deactivated. Note The central control unit automatically goes back to the previous wireless mode 15 minutes after the last wireless device got a subscription. DCN Wireless | Installation and User Instructions | Central Devices 12.4 Microphone modes 12.4.1 Introduction Select the microphone mode with the 4C Mic. Mode menu item (refer also to 10.6.8). You must also set the maximum number of activated delegate microphones. Note The system has 4 audio channels. The delegates can use three channels, the chairmen can use one channel. When more than one chairman devices are installed in the system, the next chairman that activates his or her microphone automatically deactivates the microphone of the previous chairman. 12.4.2 Open In the Open mode, delegates can activate their microphones with the microphone button on their contribution devices. When the maximum number of delegates speak, the next delegate that activates his or her microphone makes a request-to-speak. The microphone is not activated until another delegate deactivates his or her microphone. Note Microphones of chairman devices can always be activated in the Open mode. Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 63 12.4.3 Override In the Override mode, delegates can activate their microphones with the microphone button on their contribution device. When the maximum number of delegates speak, the next delegate that activates his or her microphone automatically deactivates the microphone that was activated for the longest time. Note Microphones of chairman units can always be activated in the Override mode. 12.4.4 PTT In the PTT (push-to-talk) mode, the delegates can activate their microphones with the microphone button on their contribution devices. The microphone is activated as long as the microphone button is pushed. When the maximum number of delegates speak, the other delegates cannot activate their microphones. Note Microphones of chairman units can always be activated in the PTT mode. 12.4.5 Auto mic off Enable or disable the auto microphone off function with the 4Ka Auto mic off menu item. When the auto microphone off function is enabled, the microphones of the wireless devices are automatically deactivated when they are not used for 30 seconds. DCN Wireless | Installation and User Instructions | Central Devices 12.5 Repetition rate When other wireless networks cause interference, the audio quality can decrease. In some cases, you can increase the repetition rate of the audio packets to improve the audio quality. You can change the repetition rate of the audio packets with the 4Kc Repetition menu item. en | 64 12.6.2 Recorder In the Recorder mode, audio output 2 of the central control unit transmits a signal that you can connect to an external audio recorder (refer to figure 12.1). The central control unit has no effect on the volume level of the signal. In the Recorder mode, the signal on audio input 2 of the central control unit is added to the floor signal. Note When you increase the repetition rate, the audio delay is increased. 12.6 Audio routing modes 3< 12.6.1 Introduction You can set the audio routing mode of the system with the 4E Routing I/O 2 menu item. The functions of audio input 1 and audio output 1 of the central control unit are the same in each audio routing mode. The signal on audio input 1 is always added to the floor signal. The signal on audio output 1 is always suitable to connect the system to an external public address system (for example, Praesideo). C I DCN-SW Legend C Contribution devices DCN-WCCU I Interpretation devices figure 12.1: Recorder Bosch Security Systems | 2007-11 | 9922 141 70691 en Optical network Chime DCN Wireless | Installation and User Instructions | Central Devices en | 65 12.6.3 Equalized PA 12.6.4 Insertion In the Equalized PA mode, audio output 2 of the central control unit transmits a signal that you can connect to an external public address system (refer to figure 12.2). The central control unit sets: • The volume level of the signal • The levels of the bass of the signal • The level of the treble signal In the Insertion mode, audio output 2 and audio input 2 of the central control unit are used to add signals from external audio devices (refer to figure 12.3). For example, you can connect an external audio mixer between audio output 2 and audio input 2 of the central control unit. In the Equalized PA mode, the signal on audio input 2 of the central control unit is added to the floor signal. 3< 3< C I C I DCN-SW DCN-SW Legend C Contribution devices DCN-WCCU I Interpretation devices Legend C Contribution devices DCN-WCCU I Interpretation devices Optical network Chime figure 12.2: Equalized PA Bosch Security Systems | 2007-11 | 9922 141 70691 en Optical network Chime figure 12.3: Insertion In the Insertion mode, you must install a device between audio output 2 and audio input 2 of the central control unit. When you do not install a device, the audio signals from contribution devices (floor) leave the system, but do not enter the system again. DCN Wireless | Installation and User Instructions | Central Devices en | 66 12.6.5 Mix-minus 12.7 Attention chimes In the Mix-minus mode, audio output 2 and audio input 2 of the central control unit are used to connect 2 systems (refer to figure 12.4). Use the Mix-minus mode to connect the audio of two systems. The Mix-minus connection does not cause acoustic feedback. The central control unit can play an attention chime when the chairman: • Pushes the priority button on the chairman device. • Starts a voting session. You can enable or disable attention chimes with the 4F Att. Tones menu item (refer also to 10.6.8). There are 3 different attention chimes available. 12.8 3< C I DCN-SW Legend C Contribution devices DCN-WCCU I Interpretation devices Optical network Chime figure 12.4: Mix-minus When you connect two systems: • Go to menu item 4E Routing I/O 2 to set the systems in the Mix minus mode. • Connect audio input 2 of the first system to audio output 2 of the second system. • Connect audio output 2 of the first system to audio input 2 of the second system. Note When the distance between the two systems is great, you can use a telephone coupler to connect the two systems. Bosch Security Systems | 2007-11 | 9922 141 70691 en Erase requests-to-speak and speakers The central control unit can erase the requests-to-speak and speakers when the chairman pushes the priority button on the chairman device. You can enable or disable this function with the 4G Mic. Priority menu item (refer to 10.6.8). • If you set the menu item to Permanently off, the system does not activate the microphones of the delegates again when the chairman releases the priority button. The requests-to-speak and speakers are erased. • If you set the menu item to Temporarily off, the system activates the microphones of the delegates again when the chairman releases the priority button. The requests-to-speak and speakers are not erased. 12.9 Floor distribution The central control unit can send the floor signal to all empty channels in the system. You can enable or disable this function with the 4I Floor Distr. menu item (refer to 10.6.8). • If you set the menu item to Off, the central control unit does not send the floor signal to all empty signals in the system. • If you set the menu item to On, the central control unit sends the floor signal to all empty channels in the system. DCN Wireless | Installation and User Instructions | Central Devices 12.10 Intercom Note You can make an intercom device with the DCN-DDI Dual Delegate Unit (refer to chapter ). en | 67 12.10.3 Location of the chairman To identify the location of the chairman: 1 Go to the 4Jb Assign menu item of the configuration menu of the central control unit. 12.10.1 Introduction To enable the intercom you must first identify the locations of the operator and the chairman. 2 Set the value of the parameter in the menu item to Yes. The display of the central control unit shows: 12.10.2 Location of the operator To identify the location of the operator: 1 Select the 4Ja Assign menu item of the configuration menu of the central control unit. 3 Lift the receiver of the intercom handset of the chairman to identify the location of the chairman. When the central control unit identifies the location, the display of the central control unit shows: 2 Set the value of the parameter in the menu item to Yes. The display of the central control unit shows: 3 Lift the receiver of the intercom handset of the operator to identify the location of the operator. When the central control unit identifies the location, the display of the central control unit shows: Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Central Devices en | 68 13 System operation 13.2 13.1 Start the system Do as follows: 1 Select the 4A Wireless Mode menu item of the configuration menu of the central control unit. 2 Set the value of the parameter in the menu item to Off. All wireless discussion units are deactivated. 3 Push the on/off switch of the central control unit. The display goes off. All devices in the DCN and the optical network are deactivated. Before starting the system, make sure: • the system is correctly installed. • the required number of wireless discussion units have been subscribed. Do as follows: 1 Push the on/off switch on the central control unit. The display comes on. All devices in the DCN and optical network are activated. 2 Install the battery packs in the wireless discussion units. 3 Push the microphone buttons on the wireless discussion units to activate the wireless discussion units. The LED around the microphone button comes on as yellow for 250 milliseconds (if the software version of the wireless discussion unit is lower than 2.35, the LED around the microphone button comes on as green for 2 seconds). • • • If all LEDs of the wireless discussion unit are off, the wireless discussion unit is activated, and ready to use. If the LED around the microphone button stays on as yellow, and the indicator ring of the microphone comes on as red, the wireless discussion unit cannot find the subscribed wireless network. If the wireless network is found within 15 minutes, the wireless discussion unit connects. If not, the wireless discussion unit automatically deactivates (if the software version of the wireless discussion unit is lower than 2.35, the LED around the microphone button alternates red and yellow for 5 seconds to indicate that the wireless discussion unit cannot find the subscribed wireless network. If the wireless network is found within 5 seconds, the wireless discussion unit connects. If not, the wireless discussion unit automatically deactivates). If you want to use the wireless discussion unit in a new system, but it is already subscribed to another system (see previous bullet point), you must first deinitialize the unit (refer to section 14.6.3). After the unit has been de-initialization it must be subscribed to the new system (refer to section 14.6.2). Bosch Security Systems | 2007-11 | 9922 141 70691 en Stop the system Note If necessary, charge the battery packs. DCN Wireless | Installation and User Instructions | Contribution Devices Section 3 - Contribution Devices Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 69 DCN Wireless | Installation and User Instructions | Contribution Devices 14 DCN-WDU Wireless Discussion Units 14.1 Introduction With the wireless discussion units, the delegates and chairmen can make contributions to a discussion. The chairmen can also use their wireless discussion units to monitor and control a discussion. 14.2 en | 70 Controls, connectors and indicators 14.2.1 Top The top of the wireless discussion units (refer to figure 14.1) contains: 1 Microphone socket - Connects a DCN-MICL or DCN-MICS Pluggable Microphone to the wireless discussion unit (refer to chapter 15). 2 Loudspeaker - Gives the audio signal from the floor to the delegate or the chairman. When the microphone is activated, the signal of the loudspeaker is muted. 3 Volume buttons - Change the volume level of the signal that is sent to the headphones. 4 Microphone buttons - Activate or deactivate the microphone. Each microphone button has a LED that shows the condition of the microphone. The mode of the wireless discussion unit (refer to section 14.8.4) gives the type and number of microphone buttons that you must install in the wireless discussion unit. 5 Voting buttons - Operate the wireless discussion unit. Each voting button has a yellow LED. 6 Channel selector display - Shows the number of the channel and the abbreviation of the language that is sent to the headphones (refer to appendix B in the DCN Next Generation Installation and User Instructions). When the display shows FLR, the floor signal is sent to the headphones. Bosch Security Systems | 2007-11 | 9922 141 70691 en Notee You can change the type of language abbreviation with menu e of the installation menu of the interpreter desk (refer to Section 33 in the DCN Next Generation Installation and User Instructions). 7 Channel selector buttons - Select the channel that is sent to the headphones. 14.2.2 Left and right sides The left and right sides of the wireless discussion units (refer to figure 14.3) contain: 8 Headphones socket - Connect headphones to the wireless discussion unit (refer to section 14.7.1). 14.2.3 Bottom side The bottom side of the wireless discussion units (refer to figure 14.4 and figure 14.5) contains: 9 Battery pack container - Contains the DCN-WLION Battery Pack (refer to chapter 16). 10 Configuration switches - Configure the wireless discussion unit (refer to section 14.3) and set the mode of the wireless discussion unit (refer to section 14.4). 11 De-init switch - Erases the subscription from the wireless discussion unit (refer to section 12.2). 12 Power supply socket - Connects a DCN-WPS Power Supply Adapter to the wireless discussion unit. 14.2.4 Rear side The rear side of the wireless discussion units (refer to figure 14.6) contains: 13 Status LEDs - Give information about the condition of the wireless discussion unit (refer to section 14.8.6). DCN Wireless | Installation and User Instructions | Contribution Devices DCN-WD en | 71 DCN-WDV figure 14.1: Top views (1) Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN-WDD DCN Wireless | Installation and User Instructions | Contribution Devices en | 72 DCN-DISDCS DCN-DISCS DCN-DISVCS figure 14.2: Top views (2) Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Contribution Devices en | 73 12 figure 14.5: Bottom view (2) figure 14.3: Side views 13 10 11 figure 14.4: Bottom view (1) Bosch Security Systems | 2007-11 | 9922 141 70691 en figure 14.6: Rear view DCN Wireless | Installation and User Instructions | Contribution Devices 14.3 Internal settings 14.3.1 Introduction With the configuration switches on the bottom of the wireless discussion unit (refer to figure 14.4, no. 10), you can configure the wireless discussion unit. 14.3.2 Microphone sensitivity When the configuration switches are in the correct position (refer to table 14.1), you can adjust the microphone sensitivity of the wireless discussion unit between -2 and 2 dB. • Note The internal settings apply to the wireless discussion unit. When the wireless discussion unit is in the dual delegate mode (refer to section 14.4.5), the internal settings are the same for the two delegates. table 14.1: Internal settings II Internal setting Microphone sensitivity (refer to section 14.3.2). Default: 0 dB. Channel/volume restore function (refer to section 14.3.3). Default: disabled. Headphones level reduction (refer to section 14.3.4) Default: disabled. Note The central control unit does not keep the internal settings of the wireless discussion units. After you set the mode (refer to section 14.4), the wireless discussion unit keeps the internal settings. Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 74 • To increase the microphone sensitivity with 0.5 dB, push the > volume button. To decrease the microphone sensitivity with -0.5 dB, push the < volume button. Note When the wireless discussion unit has two sets of volume buttons, configure the microphone sensitivity with the right set of volume buttons. The microphone sensitivity cannot be configured with the left set of volume buttons. The LED around the microphone button shows the sensitivity (refer to table 14.2). table 14.2: Microphone sensitivity Microphone button LED Sensitivity Red -2 dB Off -1.5 dB Red/Yellow -1 dB Off -0.5 dB Yellow 0 dB Green/Yellow 1 dB Off 1.5 dB Green 2 dB DCN Wireless | Installation and User Instructions | Contribution Devices en | 75 14.3.3 Channel/volume restore function 14.3.4 Headphones level reduction When the configuration switches are in the correct position (refer to table 14.1), you can enable or disable the channel/volume restore function of the headphones connection of the wireless discussion unit. • To enable the channel/volume restore function of the headphones, push the > volume button. (The LED around the microphone buttons come on as green.) When the wireless discussion unit is enabled, it automatically sets the last known volume and channel. • To disable the channel/volume restore function of the headphones, push the < volume button. (The LED around the left microphone button comes on as red.) When the wireless discussion unit is enabled, it automatically sets the channel to floor, and the volume to -18 dB. When the configuration switches are in the correct position (refer to table 14.1), you can enable or disable the headphones level reduction of the wireless discussion unit. • To enable the headphones level reduction, push the > volume button. (The LED around the left microphone button comes on as green.) When the microphone is enabled, the headphones level reduction is 18 dB. Note When the wireless discussion unit is in the dual delegate mode (refer to section 14.4.5) and the headphones level reduction is enabled: • The signal that is sent to the left headphones socket is decreased when the left microphone button is pushed. The signal that is sent to the right headphones socket is not decreased. • The signal that is sent to the right headphones socket is decreased when the right microphone button is pushed. The signal that is sent to the left headphones socket is not decreased. Note When the wireless discussion unit has two sets of volume buttons, configure the channel/ volume restore function with the right set of volume buttons. The channel/volume restore function cannot be configured with the left set of volume buttons. For example, you can enable this function in discussions in which the delegates and chairmen always use the same wireless discussion unit. • To disable the headphones level reduction, push the < volume button. (The LED around the left microphone button comes on as red.) When the microphone is enabled, there is no headphones level reduction. Note When the wireless discussion unit has two sets of volume buttons, configure the headphones level reduction with the right set of volume buttons. The headphones level reduction function cannot be configured with the left set of volume buttons. For example, you can enable this function to avoid acoustic feedback between the microphone and the headphones of the wireless discussion unit. Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Contribution Devices 14.4 Modes 14.4.1 Overview With the configuration switches on the bottom of the wireless discussion unit (refer to figure 14.4, no. 10), you can configure the mode of the wireless discussion unit. Each type of wireless discussion unit can operate in a number of modes (refer to table 14.3). table 14.3: Modes II Mode Single delegate (refer to section 14.4.3) Chairman (refer to section 14.4.4) Dual delegate (refer to section 14.4.5) Single delegate with auxiliary control (refer to section 14.4.6) 14.4.2 Procedure 1 Remove the battery pack from the wireless discussion unit. Note When you do not remove the battery pack, you can cause an incorrect operation of the wireless discussion unit. 14.4.3 Single delegate When the wireless discussion unit is in the single delegate mode, it is a delegate device for 1 delegate. You can put all types of wireless discussion units in the single delegate mode. When you put the wireless discussion unit in the single delegate mode, you must also install the default microphone button (refer to figure 14.7 and section 14.5.2). figure 14.7: Default microphone button Note All wireless discussion units are delivered with the default microphone button. 14.4.4 Chairman When the wireless discussion unit is in the chairman mode, it is a chairman device for 1 chairman. You can put all types of wireless discussion units in the chairman mode. When you put the wireless discussion unit in the chairman mode, you must also install the DCN-DISBCM Buttons (refer to figure 14.8 and section 14.5.2). 2 Change the mode of the wireless discussion unit (refer to table 14.3). 3 Re-install the battery pack in the wireless discussion unit (refer to section 14.5.3). figure 14.8: DCN-DISBCM Buttons Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 76 DCN Wireless | Installation and User Instructions | Contribution Devices The only difference between a delegate wireless discussion unit and a chairman wireless discussion unit is the priority button on the left of the microphone button. With the priority button, the chairman can deactivate the microphones of all delegate devices. At the same time, the priority button activates the microphone of the chairman. The system has the possibility to: • Play an attention chime when the chairman pushes the priority button (refer to section 12.7). • Erase the requests-to-speak and the speakers when the chairman pushes the priority button (refer to section 12.8). Note The DCN-DISBCM Buttons come with a tool that you can use to remove the old buttons from the wireless discussion unit (refer to figure 14.10). 14.4.5 Dual delegate When the wireless discussion unit is in the dual delegate mode, it is a delegate device for 2 delegates. The system sees the wireless discussion unit as two separate devices, but it gives only one address to the wireless discussion unit. You can only put these types of wireless discussion units in the dual delegate mode. • DCN-WDD • DCN-WDDCS en | 77 When you put the wireless discussion unit in the dual delegate mode, you must also install the DCN-DISBDD Buttons (refer to figure 14.9 and section 14.5.2). figure 14.9: DCN-DISBDD Buttons Note The DCN-DISBDD Buttons come with a tool that you can use to remove the old buttons from the wireless discussion unit (refer to figure 14.10). 14.4.6 Single delegate with auxiliary control When the wireless discussion unit is in the single delegate with auxiliary control mode, it is a delegate device for 1 delegate. The delegate can use the left microphone button as an auxiliary button. For example, to activate an indicator. Note When the delegate pushes the auxiliary button, the auxiliary button makes an event. Use the Open Interface to program the actions that must be started by the event. Refer to the applicable Software User Manual for instructions that tell you how to program the Open Interface. You can only put these types of wireless discussion units in the single delegate with auxiliary control mode: • DCN-WDD • DCN-WDDCS • DCN-WDV • DCN-WDVCS When you put the wireless discussion unit in the single delegate with auxiliary control mode, you must also install two microphone buttons (refer to section 14.5.2). Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Contribution Devices For example, you can use the DCN-DISBCM Buttons (refer to figure 14.8). 14.5 Installation 14.5.1 General Caution Do not open the wireless discussion unit. Any hardware change makes the product certificates invalid. Only qualified personnel can open the wireless discussion unit. table 14.4: Physical characteristics Dimensions (h x w x d): 61 x 190 x 160 mm Weight: • DCN-WD: 0.485 g • DCN-WDD: 0.500 kg • DCN-WDV: 0.505 kg • DCN-WDCS: 0.495 kg • DCN-WDDCS: 0.515 kg • DCN-WDVCS: 0.520 kg 14.5.2 Microphone buttons Note Before you install the microphone buttons, make sure that the wireless discussion unit operates correctly. Defective wireless discussion units are always replaced with a wireless discussion unit that contains the default microphone button (refer to figure 14.7). The mode of the wireless discussion unit (refer to section 14.4) gives the type and number of microphone buttons that you must install in the wireless discussion unit. Refer to figure 14.10 for instructions that tell you how to remove microphone buttons from a wireless discussion unit. figure 14.10: Remove microphone buttons Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 78 DCN Wireless | Installation and User Instructions | Contribution Devices Refer to figure 14.11 for instructions that tell you how to install microphone buttons in a wireless discussion unit. en | 79 14.5.3 Battery Refer to figure 14.12 for instructions that tell you how to install a DCN-WLION Battery Pack in the wireless discussion unit. 01 figure 14.11: Install microphone buttons 02 figure 14.12: Install a battery pack Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Contribution Devices 14.5.4 Rims 14.6 en | 80 Subscription 14.6.1 Introduction Note Before you install the rim, make sure that the wireless discussion units operates correctly. Defective wireless discussion units are always replaced with a wireless discussion unit without a rim. The wireless discussion units are delivered without rims. With the rims, you can change the look of the wireless discussion unit. Refer to figure 14.13 for instructions that tell you how to attach a rim to a wireless discussion unit. Caution Do not remove the rim from a wireless discussion unit. Only qualified personnel can remove rims from wireless discussion units. figure 14.13: Attach a rim Bosch Security Systems | 2007-11 | 9922 141 70691 en Each wireless discussion unit in the system must have a subscription. The central control unit cannot send data to a wireless discussion unit that does not have a subscription. Note Refer to section 12.2 when the central control unit must give subscriptions to all wireless network devices. DCN Wireless | Installation and User Instructions | Contribution Devices 14.6.2 Procedure • If after pushing the microphone button for the first time, the ring around the microphone button is yellow for 250 milliseconds and then goes off, the wireless discussion unit was already subscribed to this system - you did not have to put the system in subscription mode. Instead switch on the unit as described in section 13.1 (if the software version of the wireless discussion unit is lower than 2.35, the ring around the microphone button is green for 2 seconds). • If after pushing the microphone button for the first time, the yellow LEDs around the microphone button, and the red indicator ring of the microphone are on, the wireless discussion unit is already subscribed to a system, but is not within range of this system. If the unit cannot find the system within 15 minutes, it will automatically switch off (if the software version of the wireless discussion unit is lower than 2.35, the ring around the microphone button alternates red and yellow for 5 seconds, and then the unit automatically switches off). • If after pushing the microphone button for the first time, the yellow LED comes on for 250 ms and the red microphone indicator comes on and stays on, the wireless discussion unit is already subscribed to the system, but another unit with the same address is already connected. To correct this, de-initialize the unit as described in section 14.6.3, or push the microphone button for a second time. The unit will then de-initialize. If the unit is in range of the wireless network and subscription is enabled, the unit will also subscribe (if the software version of the wireless discussion unit is lower than 2.35, the ring around the microphone button alternates red and yellow for 5 seconds, and then the unit automatically switches off. De-initialize the unit as described in section 14.6.3, and then subscribe the unit again). The procedure below is applicable for wireless discussion devices without a subscription. If the wireless discussion unit already has a subscription, first erase the subscription (refer to section 14.6.3). Do as follows: 1 Set the wireless mode of the system to Subscription (refer to section 12.3.5). 2 Insert charged batteries into the wireless discussion units. 3 Push the microphone button of the wireless discussion unit. All LEDs of the wireless discussion unit come on and stay on, and the indicator ring of the microphone comes on as red. 4 Push the microphone button of the wireless discussion unit for a second time. The unit will try to subscribe. If subscription is successful, all LEDs of the wireless discussion unit, and the indicator ring of the microphone go off (if the software version of the wireless discussion unit is lower than 2.35, all LEDs go off after 2 seconds, and the LED around the microphone is green for 5 seconds indicating that the subscription was successful. A second push on the microphone button, as required for units with software version 2.35 or higher, is not required). • If after pushing the microphone button for a second time, all LEDs around the microphone button and the indicator ring of the microphone come on again, the wireless discussion unit is either not within range of the wireless network, or the wireless mode is not set to Subscription (if the software version of the wireless discussion unit is lower than 2.35, and after pushing the microphone button for the first time, the ring around the microphone button alternates red and green for 5 seconds, the unit is either: not within range of the wireless network, the wireless mode is not set to Subscription, or the language distribution is enabled). Refer to the note under Limit 4 in section 1. Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 81 DCN Wireless | Installation and User Instructions | Contribution Devices 14.6.3 Erase the subscription 14.7 en | 82 External connections 14.7.1 Headphones Note Do not push the de-init button with a sharp object. Do as follows: Push-and-hold the de-init button of the wireless discussion unit (refer to figure 14.4), and push the microphone button of the wireless discussion unit to switch it on (if the unit is already switched on, just push the de-init button). You can connect headphones to the headphones socket of the wireless discussion unit, the headphones must have a 3.5 mm plug (refer to figure 14.14). 2 3 1 figure 14.14: 3.5 mm headphones plug, connection All LEDs of the wireless discussion unit come on, and the LED around the microphone indicator ring comes on as red. The old subscription is erased, and the unit is ready for subscription (refer to section 14.6.2). If the software version of the wireless discussion unit is lower than 2.35, the LED around the microphone button comes on as yellow for 2 seconds. table 14.5: 3.5 mm headphones plug, connection Number Signal Left Common Right Note You can connect mono headphones to the wireless discussion unit. table 14.6: Headphones sockets, details Number of connections: 2x 3.5 mm socket Location: Right and left sides Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Contribution Devices 14.7.2 External power supply When you remove the battery pack from the wireless discussion unit, you can connect the wireless discussion unit to a DCN-WPS Power Supply Adapter (refer to figure 14.15). 14.8 en | 83 Operation 14.8.1 Activation Before activating the units, make sure: • The wireless discussion units are already subscribed to the system (refer to section 14.6.2). • The system is switched on. • The wireless discussion units are in range of the system. Push the microphone button to activate the wireless discussion unit. The LED around the microphone button comes on as yellow for 250 milliseconds. The unit is now connected and can be used. If the wireless discussion unit does not behave as described above, refer to section 14.6.2 (if the software version of the wireless discussion unit is lower than 2.35, the LED around the microphone button does not come on as yellow for 250 milliseconds; the indicator ring of the microphone comes on as green for 2 seconds). figure 14.15: Power supply socket, connection table 14.7: Power supply socket, details Number of connections: Location: In battery pack container 14.8.2 Deactivation Push and hold down the volume-down and volume-up buttons for 2 seconds. 14.8.3 Quick reference card Note Refer to the Quick Reference Card of the wireless discussion unit for instructions that tell you how to operate the wireless discussion unit. 14.8.4 Microphone The colors of the LEDs of the microphone buttons show the condition of the microphone that is connected to the wireless discussion unit (refer to table 15.5). table 14.8: Condition Color Condition Red (on) Microphone active Red (flash) Last minute of speech time Green (on) Request-to-speak Green (flash) First request Bosch Security Systems | 2007-11 | 9922 141 70691 en DCN Wireless | Installation and User Instructions | Contribution Devices 14.8.5 Attendance LED table 14.9: Attendance LED Attendance LED Condition Yellow (flashing) The system requests attendance registration. Yellow (on) The attendance registration is confirmed. 14.8.6 Status LEDs The status LEDs (refer to figure 14.6, no. 13) show the condition of the wireless discussion unit. • If the yellow LED is on, the wireless discussion unit is out-of-range. • If the red LED flashes, the battery pack of the wireless discussion unit will be empty within 1 hour. If a wireless discussion unit is out of range for more than 15 minutes, it will automatically switch off. 14.8.7 Status channel selector display If the wireless discussion unit has a channel selector display, additional icons show the condition of the unit (refer to figure 14.16): • If the antenna icon is shown, the wireless discussion unit is out-of-range. • If the battery icon is shown, the battery pack of the wireless discussion unit will be empty within 1 hour. figure 14.16: Antenna and battery icon If a wireless discussion unit is out of range for more than 15 minutes, it will automatically switch off. Bosch Security Systems | 2007-11 | 9922 141 70691 en en | 84
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Modify Date : 2008:01:22 10:38:13+01:00 Create Date : 2008:01:22 10:37:23+01:00 Metadata Date : 2008:01:22 10:38:13+01:00 Creator Tool : FrameMaker 7.1 Format : application/pdf Title : untitled Document ID : uuid:eee78c94-ecf8-413d-bd74-fbc7686557a7 Instance ID : uuid:89a9ca5f-1e45-4e64-8685-a0c576bd7fed Producer : Acrobat Distiller 6.0.1 (Windows) Has XFA : No Page Count : 84 Creator : FrameMaker 7.1EXIF Metadata provided by EXIF.tools