Bosch Fire Monitoring System Data Sheet Syst En US 20412494859
User Manual: Bosch Data Sheet Fire Monitoring System
Open the PDF directly: View PDF
.
Page Count: 4
| Download | |
| Open PDF In Browser | View PDF |
Fire Alarm Systems | Fire Monitoring System Fire Monitoring System www.boschsecurity.com The Fire Monitoring System is a graphical user interface for displaying and monitoring small to medium fire alarm systems with up to 5000 detection points. It is compatible with the fire alarm panels FPA-5000 and FPA-1200. System overview The fire panels FPA-1200 or FPA-5000 can be connected to the Fire Monitoring System via an Ethernet connection. The connection must be enabled with an ADC-5000-OPC license key. For each Fire Monitoring System only one license key is needed. u Monitoring of single or networked panels u Management of up to 5000 detection points u Simultaneous connection of up to 10 clients u Extensive logging of events and operations u User friendly installation and configuration An exclusive Ethernet network in order to set up a central fire alarm network (1) is required. For security and reliability reasons, no networks used for any other purpose (2) may be part of this special network environment. The Fire Monitoring System has to be part of this exclusive fire alarm Ethernet network without direct access to the Internet (3). If an internet connection is established to receive the Fire Monitoring System license, this internet connection must be removed before the fire alarm network is put into operation. Only recommended accessories may be used. 2 | Fire Monitoring System Single panel connection TX Ethernet cable (copper) 2 Peer-to-Peer connection (100 m max.) 3 Fire Monitoring System: server 4 Fire Monitoring System: clients Panel network connection FX Ethernet cable (fiber optic) 1 2 3 1 Fire Alarm Panel (incl. ADC-5000-OPC license key) 2 Peer-to-Peer connection (100 m max.) 3 Fire Monitoring System: server 4 Fire Monitoring System: clients 4 1 Single panel connection FX Ethernet cable (fiber optic) 2 3 4 5 6 1 Ethernet network (incl. ADC-5000-OPC license key in 1 panel) 2 Ethernet switch 3 Singlemode (SM)/Multimode (MM) Fiber (40 km/2 km max.) 4 Media Converter 5 Fire Monitoring System: server 6 Fire Monitoring System: clients Functions 1 2 3 4 5 6 1 Fire Alarm Panel (incl. ADC-5000-OPC license key) 2 Media converter 3 Singlemode (SM)/Multimode (MM) Fiber (40 km/2 km max.) 4 Media converter 5 Fire Monitoring System: server 6 Fire Monitoring System: clients Importing floor plans The Fire Monitoring System supports an easy import of various file formats, including dwg and dxf. The software automatically allocates the detector list of the fire panel to the floor plan. Panel network connection TX Ethernet cable (copper) 1 1 2 User friendly installation and operation A wizard guides through the installation as well as the configuration in a few steps. Automatic transfer of the panel configuration to the software allows comfortable object management (e.g. predefined sensors). To add an object, the operator simply clicks on the desired position on the map. System devices can be allocated to objects through a drop down menu. Extended map management In each map, specific areas can be defined to create sub-maps. In case of event there is an automatic zoom into the relevant sub-map. The operator can manually zoom into maps or sub-map and a pan function allows to move the map in any direction. 3 4 CAN Network (incl. ADC-5000-OPC license key in 1 panel) Object management on the map A single sensor or a group of devices can be selected and be moved into another map by a simple Drag & Drop operation. Copy and paste of objects in different maps is supported as well. 3 | Fire Monitoring System User rights management The authorizations are based on customizable groups. The rights to access to e.g. different sources, maps, alarm zones and devices are managed at group level. Each user can be part of one or more groups. Accessories E-mail notification Events can be forwarded by e-mail to users according to their user settings. Order number ADC-5000-OPC Event logging In the event log all procedures and actions are recorded. You can search according to various criteria, cluster and generate statistics, make backups or print the event log. The reports can be exported to Excel. Connectivity A standalone fire alarm panel or a panel network with up to 5000 detection points in total can be connected to the Fire Monitoring System. Language versions The Fire Monitoring System is available in following languages: English, German, Italian, Polish, Dutch, French, Russian, Spanish, Turkish, Portuguese, Romanian. The user interface language can be individually defined by the user. Installation/configuration notes Hardware Preconditions • • • • • Processor: dual core (1,8 GHz or more) RAM: Minimum 2 GB Free Disk Space: Minimum 1 GB Network card 100 Mbps Monitor resolution: Minimum 1366x768 pixel Software Preconditions • • • • • Windows 7 (32 bit and 64 bit) Windows 8 (32 bit and 64 bit) Windows 10 (32 bit and 64 bit) Microsoft Office (Release 2007 / 2010 / 2013) .NET Framework from version 3.5.1 Ordering information Fire Monitoring System FSM-2500 Monitoring Software to manage up to 2500 detection points. Order number FSM-2500 Fire Monitoring System FSM-5000 Monitoring Software to manage up to 5000 detection points. Order number FSM-5000 Evolution pack FSM-2500 Yearly maintenance agreement for upgrades. Order number FSM-2500-EP Evolution pack FSM-5000 Yearly maintenance agreement for upgrades. Order number FSM-5000-EP Licence Key OPC Enables reliable communication between the OPC server and the FPA‑1200 panel or FPA‑5000 panel or networks. Ethernet Switch MM Order number BPA-ESWEX-RSR20 Ethernet Switch SM Order number RSR20-0800S2S2T Media Converter MM Order number EL1141-10B-BH Media Converter SM Order number EL1141-B0B-BH 4 | Fire Monitoring System Represented by: Americas: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5617 BA Eindhoven, The Netherlands Phone: + 31 40 2577 284 Fax: +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com © Bosch Security Systems 2015 | Data subject to change without notice 19131121675 | en, V2, 28. Sep 2015 Asia-Pacific: Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia China: America Latina: Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division 203 Building, No. 333 Fuquan Road Via Anhanguera, Km 98 North IBP CEP 13065-900 Changning District, Shanghai Campinas, Sao Paulo, Brazil 200335 China Phone: +55 19 2103 2860 Phone +86 21 22181111 Fax: +55 19 2103 2862 Fax: +86 21 22182398 latam.boschsecurity@bosch.com www.boschsecurity.com.cn www.boschsecurity.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2015:09:28 16:39:12+01:00 Modify Date : 2015:09:28 16:39:12+01:00 Creator : AH Formatter V5.3 MR3 (5,3,2011,1116) for Windows (x64) Producer : Antenna House PDF Output Library 2.6.0 (Windows (x64)) Title : Fire Monitoring System Trapped : False Page Count : 4EXIF Metadata provided by EXIF.tools