DCN Next Generation 4.63
Release Notes

en

Release Notes

DCN Next Generation Release Notes

en | 2

DCN Next Generation Release 4.63
Table of Contents
1
2
3
4
5
6

This release Contains ................................................................................................... 2
Improved and added Functionality ............................................................................... 2
Release Compatibility Restrictions .............................................................................. 7
Software, Firmware & FPGA versions .......................................................................... 8
Additional Information to the DCN Manuals and Help Files ...................................... 10
Trouble Shootings and known issues ........................................................................ 11

1 This release Contains
The following versions are part of this release:
Product
DCN-SW
DCN-SWSMV
DCN-SWSACC
DCN-DLT (for CCU2)
DCN-CCU2
HdCameraControl
DCN-DLT (for CCU, NCO)
DCN-CCU
DCN-MR

version
4.62
4.40
4.40
4.63
4.63
4.40
3.10
3.10
2.30

Windows 7a
Yes
Yesb
Yes
Yes
NA
Yes
Yes
NA
Yes

Windows 8.1a
Yes
Yesb
Yes
Yes
NA
Yes
No
NA
No

Windows 10a
Yes
Yesb
Yes
Yes
NA
Yes
No
NA
No

Notes:
a. home editions of Windows 7, 8.1, or 10 are not supported.
b. DCN-SWSMV: exporting voting results to PowerPoint is only supported for PowerPoint 2003.

2

Improved and added Functionality

Release
4.63

Release
Date
2017-11-29

4.62

2017-10-13

4.61

2016-9-17

Release Comments
New functionality and improvements
 Improved calibration behaviour of the optical network upon
booting and adding and removing devices from the optical
network.
New functionality and improvements
 Fixed DCN-SW cannot be installed on PC with Windows 10.
Microsoft SQL2014 will be installed with new installations. In
case of upgrades the existing SQL 2008 will be used.
New functionality and improvements
 Fixed Slave CCU resetting issue due to time out, by increasing
the time out value.

Bosch Security Systems| 2017-11-29

DCN Next Generation Release Notes

Release
4.60

Release
Date
2016-7-20

4.50

2015-11-16

4.43

2015-05-15

en | 3

Release Comments
New functionality and improvements
 Fixed DCN-SW server front end application and DCN-SW
printing application do not start on French, Portuguese and
Spanish Windows.
 Fixed issues with streaming meeting data in combination with
display application and or DCN meeting recorder.
 Fixed notebook behaviour of devices.
 Updated CCU2 firmware to support DCN-CCU2 and DCNCCUB2 hardware version HW01/04.
 Improved DCN Meeting Recorder in combination with
streaming meeting data.
New functionality and improvements
 Windows 10 supported.
 Added Hungarian translations Concentus.
 Fixed time stamp problem of DCN-MR
 Remote control via Open Interface for all (Audio) expanders.
(Digital IO contacts)
 Remote configuration via Open Interface of all expanders, AEX,
DEX, CIN ,OMI; (Routing of the DCNNG floor and languages to
all in- and outputs)
 Level control for Omneo Media Interface
 Microphone detection for Interpreter desk (internal, external,
auto) via DCN-CCU2 front panel
 tvONE C2-6204A with 4 HD-SDI inputs is supported in
HDCameraControl as successor of the tvONE C2-2355A / S2108HD combination
 Removed Webcasting software and manuals from the DVD
New functionality and improvements
 Fixed: Notification of disconnection from the Bosch DCN
Conference Software.
 Fixed: Operator application shows error and red cross after
setting the Central Control Unit to Standby
 Changed error message when an ID card reader cannot read
ID card into understandable text.
 Fixed: Discussion unit cannot be controlled from synoptic after
a reboot of the CCU.
 Fixed: Language configuration in DCN-IDESK does not change
with meeting after a reboot of the CCU.
 Improved startup behaviour of Integrus transmitter.
 Improved Mongolian translations on Concentus.
 Support of new AD convertor in Integrus Transmitter.

Bosch Security Systems| 2017-11-29

DCN Next Generation Release Notes

Release
4.42

Release
Date
2015-03-18

4.41

2014-11-02

4.40

2014-07-30

4.30

2014-01-31

en | 4

Release Comments
New functionality and improvements
 Fixed delay of voting results via SMD if a vote is cast during the
start chime
 Fixed first vote is not exported via SMD
 Fixed card production settings fall back to CRC after opening
and closing the card production settings
 Fixed error upon closing Configuration Application after
producing cards during a running meeting
 Fixed DCN-SW does not install on Turkish OS
 Fixed focus/control goes to prepared votings when a adhoc
voting is started
 Fixed problem with Black Magic card (due to new Black Magic
drivers) in DCN-SWWA webcasting
 Fixed problem with pause behavior of DCN Meeting Recorder
New functionality and improvements
 Improved DCN wireless firmware to make it more robust in
environments with a lot of WiFi communication
 Unresponsive microphone control in Operator application due
to network disconnections
 Added DCN-SW icons to DVD
New functionality and improvements
 Added Notebooker configuration to the API and
DcnApiDemonstrator
 Added AGC on/off to audio outputs of Audio Expander in
Individual Channels mode
 DCN-CCU2 supports Omneo Media Interface (PRS4OMI4) to
interface with DCN multimedia
 Added Mongolian to Concentus display
 ID cards can be programmed via API with and without CRC
 Insert and remove of ID card can be executed via API to enable
interfacing with third party identification system
 Windows 8.1 support for DCN-SW
 Windows 8.1 support for DCN-SWSMV
 Windows 8.1 support for DCN-SWSACC
 Windows 8.1 support for HdCameraControl
 Added Crystal Reports installer to Tools directory
(CRRuntime_32bit_13_0_9.msi). This needs to be installed to
print the voting reports from DCN-SWSMV.
Note
 Windows Vista is no longer supported for DCN-SW, DCNSWSMV, DCN-SWSACC, HdCameraControl
New functionality and improvements
 DcnHdCameraControl added second video switcher Kramer
MV-6
 DcnHdCameraControl made screen line configurable
 DcnHdCameraControl added camera transition time
 added create groups, rename meetings, rename sessions,
request list via API (DCN-SWAPI) including demonstrator
application with source code.
 Support for the new audio expander PRS-4AEX4 by DCNCCU2.
Fixes
 Increased the vote description from 50 to 130 characters.
 Indivual voting results not translated.

Bosch Security Systems| 2017-11-29

DCN Next Generation Release Notes

Release
4.21

4.20

Release
Date
2013-09-30

2013-07-15

en | 5

Release Comments
Fixes


Multi channel and multi lingual DCN-SWWA (version 1.1.1)
added.
 Russian helpfile missing in DCN-SW.
 Previous DCN-SW version cannot be upgraded because
database of previous DCN-SW version cannot be upgraded.
New functionality and improvements
 DCN-SW added Opinion Poll and Audience Response
(requires DCN-SWMV multi voting license)
 Select, Summon, Start, Hold, Stop of votings via API (DCNSWAPI) including demonstrator application with source code.
 DCN-SW copy vote and copy session added to Configuration
Application and API to improve usability
 Master Volume Control and Chairman Priority added to Control
API.
 Added Vietnamese and Indonesian language to DCN-SW,
DCN-SWSMV and DCN-SWSACC
 Added get and set System ID for slave CCU’s to Open
Interface
 Response list length increased from 5 to max 25 and made
configurable on CCU and via DCN-SW
 Number of Open Microphones (NOM) increased from 4 to 25.
 Number of seats which can be added to the Notebook
increased from 15 to 25.
 Increased Operator Application target size
 Added group speech timers to DCN-SWSMD (and
DcnSmdDemonstrator application)
 Added show last minute of speech by blinking microphone LED
 Added a new audio routing option to the CCU: Insert no AGC.
Fixes
 DCN-SW added Czech, language to the installer.
 Show OI connection on CCU
 Solved inconsistencies in showing voting results
 Solved SMD error regarding loss of speaker information when
chairman speaks and ID cards and speechtimers are used.
 Voting control on desktop does not show graphs for group
results

Bosch Security Systems| 2017-11-29

DCN Next Generation Release Notes

Release
4.10

Release
Date
2013-04-17

4.03

2012-07-15

en | 6

Release Comments
New functionality and improvements
 Start/Stop Meeting and Session and Microphone Management
control via API (DCN-SWAPI) including demonstrator
application with source code.
 Control of the IDesk outgoing channel using DCN Operator
Application (requires DCN-SWSI license).
 DCN-SW added Voice Activated Microphone Logging to
identify which microphone is active in VOICE mode (requires
DCN-SWVAML license). Can be used in combination with
camera control to see who is speaking is voice mode.
 DCN-SW font colour below icons on layout can be changed.
 DCN-SW Meeting can be copied (including all settings) using
Configuration Application and API.
 Demonstrator application including source code for DCNSWSMD XML streaming meeting data.
 HD Camera Control via DCN-SWSMD streaming meeting data.
 DCN-SW added Czech language to the GUI. Czech language
has to be copied manually, please refer to the Tools\Language\
directory.
 Extended the explanation about the TCP connection in Open
Interface description.
 DCN-SWWA Webcast application added. Only English User
interface. Only one audio-channel/language.
Fixes
 DCN-SWSMD information regarding microphone on off.
 DCN-SWSMD information empty when session name and
description are identical.
 Stopping an Operator-control session does not clear request
list.
 DCN-MR wave form and audio sometimes not in sync.
 DCN-SW not all GUI texts fit.
 DCN-SWSMV Reset microphone sensitivity ALL
MICROPHONES.
 DCN-CCU2 can cause acoustic feedback when powered up in
Insertion mode.
 DCN-SW added Slovenian language to GUI. Made Japanese
helpfile part of the installer. Added Thai, Polish and Finnish
language to the installer.
 DCN-SWSMD Participant is made absent when Chairman
speaks in Operator with response mode.
 Quorum shows strange behaviour with ID-cards and Secret
voting.
 Performance and stability improvements on DCN SW Server
and Operator Control
 Delegate names are not shown in speakerlist when using
access control for voting only.
Fixes
 DCN-SW Operator Application can cause a fault pop up upon
user login and start session.
 DCN-SW Configurator Application can cause a fault pop up
when a document will be inserted with a file name that is too
long.
 DCN-SW Printing Application will not start up in Spanish,
Catalan, Portuguese and Polish.

Bosch Security Systems| 2017-11-29

DCN Next Generation Release Notes

Release
4.02

Release
Date
2012-04-16

4.01

2012-03-01

4.00

2011-12-02

3.10

2011-07-26

en | 7

Release Comments
Fixes

Fixes


Inserting or withdrawing of ID-cards could lead to fault pop up.

Auto-relay is always activated when the B-output channel is
selected (Using DCN-SW with DCN-SWSI).
 DCN-CCU2 replaces DCN-CCU, DCN-WCCU and DCN-NCO
 DCN-CCUB2 replaces DCN-CCUB
New functionality and improvements
 Simultaneous Interpretation DCN-SWSI added
 Usher call and speak slowly requests support DCN-SWMD
 DCN-SW GUI languages: de, ca, en, es, fr, hu, it, jp, ko, lt, nl,
no, pt, ru, sv, zh-chs
 DCN-SW help files languages: de, en, es, fr, it, nl, zh-chs
 Seat assignment and seat definition improved
 DCN-SWSACC indicates when DCN-SWSACC licenses is
missing.

3 Release Compatibility Restrictions
The following versions are compatible with this release:
Product
Hw
FPGA
DCN-CCU2
<1.4
na
DCN-CCU2
1.4
na
DCN-CCU
1.07
DCN-CCU in multi CCU mode
>=5.0
>=2.17
LBB 4120/00 Interpreter desk
>=1.2
Toggle in DCN-IDESK
Optical devices

SW
na
na
-->=1.40.xxxx

FW
4.60
4.60a
3.1x
--5.02

Note:
a. DCN-CCU2 with hardware 1.4 could become defective if they are downgraded below software
version 4.60.
Wireless Units:
New firmware is developed for the DCN Wireless units to operate with the DCN-CCU2 (e.g.
encryption functionality). This firmware can be uploaded using the Download and License Tool
(DLT) and the Upgrade Toolkit (DCN-UPTK). This firmware works with DCN-CCU2 and DCNWCCU.
Products with the following hardware version have already this firmware installed.
Product
DCN-WD-D
DCN-WDD-D
DCN-WDV-D
DCN-WDCS-D
DCN-WDDCS-D
DCN-WDVCS-D

Bosch Security Systems| 2017-11-29

Hw
02/04
02/04
02/04
02/05
02/05
02/05

DCN Next Generation Release Notes

en | 8

4 Software, Firmware & FPGA versions
The table below provides a versions overview of parts which cannot be downloaded using the
Download and License Tool or the DCN-UPTK Wireless upgrade Tool kit.
Please contact your local Bosch representative how to update these parts.
The HW column indicates if the Hardware Version of the product is supported for the listed parts.
For product which cannot show the FPGA version, the HW version belonging to the FPGA version
is shown between brackets after the FPGA version.
DCN-CCU & DCN-WCCU
FPGA
HW
2.23
≥ 4.0
2.22
≥ 4.0
2.20
≥ 4.0
2.19
≥ 4.0
2.18
≥ 4.0

Fixes
Slow reacting Multi CCU system
Noise or no audio on delegate loudspeaker
Unstable system after start-up due to optical network disturbances
Noise on delegate loudspeaker
Unexpected beeps on delegate loudspeaker fixed

DCN-CCUB
FPGA
1.22
1.09
1.08

HW
≥ 1.0
≥ 1.0
≥ 1.0

Fixes
Noise or no audio on delegate loudspeaker
Noise on delegate loudspeaker
Unexpected beeps on delegate loudspeaker

HW
≥ 1.0
≥ 1.0

Fixes / Additions
Address might be lost after system restart
11Khz noise

≥ 1.0

CRC check added for ID-cards

DCN-DDI
FPGA
2.2 (hw02.01)
2.0 (hw02.00)

HW
≥ 1.0
≥ 1.0

Fixes / Additions
11Khz noise
CRC check added for ID-cards

DCN-DIS range
FPGA
1.20 (hw02.06)
1.18 (hw02.03)

HW
≥ 1.0
≥ 1.0

1.15
1.13 (hw02.02)

≥ 1.0
≥ 1.0

Problem fixed
11Khz noise
Disturbed audio on headphones for channels > 28
Address might be lost after system restart
Channel auto increment equal to DCN-CON
Audio distorted on headphones

DCN-FCS
FPGA
2.7 (hw02.02)

HW
≥ 2.0

Fixes
11Khz noise

HW
≥ 2.0

Fixes / Additions
11Khz noise

≥ 1.0

loudspeaker symbol might be shown in front of the quality indicator
after leaving the Idesk’s installation menu
B Toggle added

DCN-CONxx range
FPGA
1.17 (hw1.12)
1.14 (hw1.10)
SW
1.10.xxxx (hw1.13)

DCN-IDESK
FPGA
2.1
SW
1.41.xxxx
1.40.xxxx

≥ 1.0

Bosch Security Systems| 2017-11-29

DCN Next Generation Release Notes

INT-TX Range
FPGA
02.03
02.02
02.01

HW
≥ 1.0
≥ 1.0
≥ 1.0

en | 9

Fixes / Additions
The display might show unexpected characters
Improved stability when used in combination with the DCN system
Improved stability when used in combination with the DCN system

Bosch Security Systems| 2017-11-29

DCN Next Generation Release Notes

en | 10

5 Additional Information to the DCN Manuals and Help
Files
Reference
Security

DCN-SWAPI

What
Security measures
The installer is responsible for security measures to prevent improper use of the
system via the Internet and local wired or wireless networks.
Think of the following items to increase security:
 Prevent unauthorized access to the Central Control Unit
 Prevent unauthorized physical and logical access to the wired Ethernet
connection Central Control Unit
 Prevent unauthorized access to the DCN NG computer
 Change the default admin password
 Place the Central Control Unit in a separate VLANUse a firewall
Using the API in an ASP.NET environment.
Prerequisite:
The project build platform target should be x86.

During development
For developer environment in IIS express, the user has to place the
“Bosch.Dcn.Ecpc.Client.Logic.dll.config” file in following location:
C:\Program Files (x86)\IIS Express
After deploying
The user has to place the same “Bosch.Dcn.Ecpc.Client.Logic.dll.config” file in
the following location:
C:\Windows\SysWOW64\inetsrv

Bosch Security Systems| 2017-11-29

DCN Next Generation Release Notes

Reference
DCN-SW

Wireless
Discussion
Units
DCNSWSMV

DCNSWSMV

en | 11

What
When installing DCN-SW on a Windows 7 PC you might get the following
notification:

This is because within the time installer checks for framework, SQLServer
installation starts which prompt for the framework installation.
Please press OK, after this the framework will be installed from the DCN-SW
installer and DCN-SW installation will install successful.
Wireless Discussion Units which are produced before 2012 need to be upgraded
using the DCN-UPTK and DLT (4.xx) in order to operate with a DCN-CCU2.
Showing voting results in PowerPoint
In case PowerPoint is used to show the voting result, it might happen that
PowerPoint starts and overlaps the user interface of DCN-SWSMV completely.
Use the Windows task bar to select DCN-SWSMV again.
Printing voting results
To print voting results, Crystal Reports needs to be installed. It is located in the
Tools directory of the DVD (CRRuntime_32bit_13_0_9.msi).

6 Trouble Shootings and known issues
This trouble shootings and known issues are in addition to chapter 2 and to the trouble shooting
chapter in the user manuals.
Product/function
Problem
Solution
DCN-SW control
When changing the
No solution available
microphone
sensitivity of the
Audio clicks are only heard while increasing or
sensitivity of
microphone of the
decreasing microphone sensitivity of DCN-IDESK.
DCN-IDESK
DCN-IDESK will result
in short audio clicks.
DCN-SW
In rare occasions it
Restart the DCN-SW Configuration Application.
Configuration
can happen that the
Application
application closes
unintended.
DCN-SW rinting
Individual voting
Change the voting template accordingly:
individual voting
results are not printed
1. Check the “Automatic print after stop of the
results manually
when printed
voting” checkbox.
manually via Bosch
2. Change the settings to Total, groups and
DCN SW Print
individuals.
Application.
3. Uncheck “Automatic print after stop of the
voting” checkbox.
DCN-SW multi PC Client cannot connect Configure the adapter settings in such a way that the
with Server when
network adapter which is used for DCN NG is the
multiple network
highest in the list of connections in Adapters and
adapters are available Bindings
DCN-SW
Delegate both in
If a delegate is both in the Request to Respond as in
Request to speak as
the Request to Speak list and you want to shift the
Request to respond
Request to Speak to Speaking, first cancel the
list.
Request to Respond.

Bosch Security Systems| 2017-11-29

DCN Next Generation Release Notes

Product/function
DCN-SW

Problem
On 64-bit operating
systems, it might
difficult to find
previous SQL-server
during DCN-SW
installation, when
initial SQL-installation
was not default.

DCN-SW

System overview
does not show all
connected devices
when system is still
powering up.
DCN-SW Master
Volume is different
from CCU volume
control

DCN-SW

DCN-SW

Downgrade to
versions <3.10 not
possible.

DCN-SW

Unexpected
behaviour or no
reaction of DCN-SW.

DCN-SW

Generates errors after
Windows Stand by..
Secret mode does not
work in ad-hoc voting
Voting attention tone
cannot be changed
during a running
meeting.
Error code 2869 or
Fatal error during
installation.
Error notification upon
closing DCN-SWSMV
directly after opening
it.

DCN-SWPV
DCN-SWPV

DCN-SW setup
repair
DCN-SWSMV

DCN-SWSMV help
file

When opening help
file you get an error.

Bosch Security Systems| 2017-11-29

en | 12

Solution
During installation of DCN-SW the installation process
might not be able to find the previous SQL-server, in
case during initial installation another name for the
SQL-server was created, instead of using the default
name. Therefore it is recommended to use the default
name and folder during initial SQL-installation. If a
SQL-server with a non-default name needs to be
found, the correct name should be entered manually
in the applicable box during DCN-SW installation.
Wait until DCN-system is powered up completely and
then check the connected devices via DCN-SW
configuration application VIEW \ System Overview.

When the Master Volume of the CCU has been
changed while DCN-SW was disconnected, the DCNSW Master Volume will not reflect the CCU-setting.
Changing the DCN-SW volume setting, will make
them identical again.
Manually uninstall SWL server 2008.
Note that the DCN-SW database (the database
contains all settings like seats, meetings, synoptic
layouts, etc.) will always be removed during a
downgrade.
Due to Windows Automatic Updates some critical
components like SQL Server Express might be
temporarily not available for DCN-SW.
Do not set Automatic Updates to Automatic or restart
your system after the Automatic updates have been
installed.
Disable Stand by functionality in the Windows
operating system.
Update to version 2.80 or higher
The voting attention tone can be changed in the
voting template but becomes effective after a vote has
been selected or started.
Remove DCN-SW with DCN-SW setup and make a
new installation. Settings are stored in the SQLdatabase and can be re-used in the new installation.
Please wait at least 10 seconds to close DCNSWSMV after opening it.

Just close the error notification.

DCN Next Generation Release Notes

Product/function
DCN-SWSMV

Problem
DCN-SWSMV will not
start

Wired and wireless
system in
combination with
Integrus

No audio on DCN
wired and wireless
units when powering
up DCN-CCU2 and
Integrus transmitter
simultaneous.
DCN-DLT is not able
to download the
firmware of the CCU

Not able to
download DCNCCU2 firmware

HD Conference
Dome

DCN-UPTK

DCN-CCU(B)2

DCN-CONFF and
DCN-CONCM

DCN-SWSACC
and Allegiant

The HD Conference
Dome will show an
incorrect name &
picture combination if
a new pre-position is
asked before it
reaches it’s preposition.
The type of the unit
connected to the
UPTK is not valid.
Error relays activated
upon system reset or
firmware download.
DNPV answers in
voting are not visible
in the Concentus
screen when a voting
timer is activated.
Double screenlines
are still visible on
audience screens
after switching to
single screenlines.

Bosch Security Systems| 2017-11-29

en | 13

Solution
Voting legends cannot be changed into “Not Voted”.
Remove “BCPCSettings.xml” which can be found:
For XP:
“…\Documents and Settings\All Users\Application
Data\Bosch\DCN Synoptic Microphone and Voting
Software\x.xx”
For Vista:
“…\Programdata\Bosch\DCN Synoptic Microphone
and Voting Software\x.xx”
First power up the DCN-CCU2. After it is powered up,
power up the Integrus transmitter.
Note: in a system with DCN-CCU2 and other optical
devices; always first power up the DCN-CCU2 before
powering other optical devices.
Check if the DCN-SW server is not running:
1. Exit the DCN-DLT program
2. Check if the DCN-CCU2 does not report PC
on it’s display. If it does Stop the DCN-SW
server via Start\ 
SERVICES. Services (local). And check if PC
disappears.
3. Start DCN-DLT (PC will now re-appear in the
CCU2 screen, but that is correct) and start
the download.
If the download still fails, do the following:
1. Power off and open the DCN-CCU2
2. Set switch 8 of S600 to ON and power on the
CCU.
3. Download the CCU using the DCN-DLT.
4. After a succesfull download, power off the
CCU, set switch 8 of S600 to OFF again and
power on the CCU.
Do not activate another microphone until the HD
Conference Dome has reached it’s pre-position.

This notification can occur when the DCN-UPTK unit
is used extensively. Please replace the connection
cable.
During a firmware download or system reset, the
system is not in normal operation and thus the error
relays can be active.
Use a hall display or disable the voting timer.

Restart the Allegiant.

DCN Next Generation Release Notes

Product/function
DCN-SWSACC
DCN-MR

DCN-MR

Problem
Upload does not work
anymore.
DCN-CCU(B)2 goes
to Open mode after
closing DCN-MR
application.

DCN-MR does not
connect to DCN-SW
when installed on
another PC

en | 14

Solution
Restart the DCN-CCU or DCN-NCO.

In a system where:
1. The DCN-CCU(B)2 is connected to DCN-SW or
DCN-SWSMV and
2. Connected to DCN-MR via Open Interface
and
3. The CCU is in Operator mode.
It will go to Open mode if:
 It loses connection with DCN-MR (e.g. the
application is stopped)
To restore the microphone mode to Open mode, the
microphone mode needs to be set to Open mode via
DCN-SW or DCN-SWSMV.
Note: it will also go to Open mode if it loses
connection with DCN-SW or DCN-SWSMV. So that
the meeting can still continue.
1. Open the Meeting Recorder.ini file with notepad
it is located here: C:\Users\[USER
NAME]\AppData\Roaming\Meeting Recorder
if the user name is administrator, the path will
be: C:\Users\
Administrator\AppData\Roaming\Meeting
Recorder
2. Find the variable NCO Ip=x.x.x.x (where x.x.x.x is
the IP address of DCN SW server) and below that
line;
Create a line DCO Ip=x.x.x.x (where x.x.x.x is the
IP address of the DCN SW server)
NCO
NCO
DCO
CCU

Port=20000
Ip=10.120.22.230
Ip=10.120.22.230
Ip=192.168.1.1

3. Save the Meeting Recorder.ini file
DCN-MR

Multi CCU systems

Windows audio
playback is lost after
installation DCN-MR
1.3. in windows XP.
System reaction is
(very) slow after
system startup.

Bosch Security Systems| 2017-11-29

Replace files msacm32.drv, msadp32.acm and
imaadp32.acm in the windows system32 folder.

The system might become (very) slow when in a multi
CCU system only the NCO is switched off and the
rest of the system stays switched on.
To prevent this problem:
Shutdown all optical devices in the Multi-CCU system.

DCN Next Generation Release Notes

Product/function
DCN-NCO

Problem
DCN-NCO cannot be
downgraded or
upgraded.

en | 15

Solution
A known issue is that DCN-NCO cannot be
downgraded from SW 2.70.
Workaround
1) Install the Download and License Tool of the
version you want to use to downgrade or upgrade
to.
2) Open Notepad and paste the text below into
Notepad
user target password
cd /rfa
dele PDSDATA1.PDS
dele PDSDATA2.PDS
bin
hash
cd /rfa/drv
put mmu_3.bit
put mif_3.bit
cd /bim
put dune.bim
bye

DCN-CCU DCNNCO
DCN-NCO
DCN-CCU,
INT-TX04/08/16/32
DCN NCO
DCN-CCU
INT-TX04/08/16/32
DCN NCO
DCN-CCU
INT-TX04/08/16/32

Local floor muted after
download of NCO or
CCU
Unexpected behavior
when adding powered
system units to the
optical ring
Audio disruption when
switching on a
transmitter
Audio disruption when
one of the CCUs is in
the mode
“--“

Bosch Security Systems| 2017-11-29

3) Save the file in Notepad to C:\Program
Files\Bosch\Digital Congress Network\Download
and License Tool\Files with name dcn-nco.txt
4) Switch off the NCO and set dipswitch 1 of S3 to
on, set all other switches to off
5) Switch on the NCO
6) Open a command prompt (start -> run -> cmd)
and change to the following folder: C:\Program
Files\Bosch\Digital Congress Network\Download
and License Tool\Files
7) Download the NCO with the next command line
FTP with the command:
ftp -n -s:dcn-nco.txt x.x.x.x
Where x.x.x.x is the IP-address of the NCO
8) Switch off the NCO and set the dipswitches all to
off
9) Switch on the NCO
10) Start the Download and License Tool and start a
NCO download.
Switch off and on the CCU or NCO

In case system units are added to the optical ring
when the system is powered on, unexpected behavior
can occur. Only connect units to the optical network
when all units are powered off.
Select the option “enabled” in menu 4b (network
mode).
Change the slave id “--" to a number. (refer to menu
7I Multi Mode).

DCN Next Generation Release Notes

Product/function
INT-TX04/0816/32

INT-RX04/08/32

DCN-CCU

DCN-CCU

DCN-CCU

LBB 4402/00
LBB 4404/00
PRS-4DEX4
INT-TX

DCN-IDENC

CNConfig

Problem
The transmitter
displays the message
“No Network”
Charging indicator on
the receiver is blinking

DCN-CCU shows
“Multi” while acting in
“Single”

Audio disruption
during powering
up/down a CCU in a
Multi CCU system
Loss of settings after
reboot of NCO in a
Multi CCU system

Input routing does not
work after download
of optical devices
Transmitter does not
work after updating
firmware
DCN-IDENC ID card
encoder in not
recognized in DCNSW.
Error during
installation “…verify
that you have access
to the directory.”

Bosch Security Systems| 2017-11-29

en | 16

Solution
Connect a powered DCN Next Generation or DCN
wireless system to the transmitter or select the option
“standalone” in menu 4b (network mode)
Check whether the receiver is still working correctly. If
this is the case: the battery pack is fully charged and
can be recharged after using it a while.
If this is not the case: follow the instructions as given
in the troubleshooting table.
When changing from “single” to “multi” mode, the
DCN-CCU can remain working in “single” mode.
If this is the case follow next procedure:
1. Select “multi” on all connected CCUs
2. Switch off all CCUs.
3. Reset to defaults the NCO.
4. Switch on all CCUs.
During powering up/down a CCU in a Multi CCU
system the audio on the delegate units, connected to
the remaining CCU’s, is shortly disrupted for 1 to 2
seconds.
In case the Network Controller (NCO) in a Multi CCU
system is rebooted, the settings and configurations
changed during the past 30 seconds can be lost.
When configuring interpreter desks wait minimum 30
seconds before reboot the NCO.
Change all inputs to CH00 and then to the required
channel.
Update FPGA to version 2.03 or higher
Alternative solution:
Update firmware of the INT-TX to version 2.80
If other card readers/encoders are present or
connected to the PC please disable them.
Internal readers/encoders can be disabled in the
BIOS or in the Windows Device Manager.
Ensure that you have the required administrator
rights. Restart installation.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 16
Producer                        : doPDF Ver 8.4 Build 935
Create Date                     : 2017:11:29 13:18:48+01:00
EXIF Metadata provided by EXIF.tools

Navigation menu