Boschhome 18 Dec Users Manual
1825 to the manual 02517d3f-8d9b-4ca8-91dd-c294f05ce309
2015-01-21
: Boschhome Boschhome-18-Dec-Users-Manual-238603 boschhome-18-dec-users-manual-238603 boschhome pdf
Open the PDF directly: View PDF .
Page Count: 52
Download | |
Open PDF In Browser | View PDF |
GREENSTAR HEATSLAVE EXTERNAL 12/18, 18/25, 25/32kW FLOOR STANDING EXTERNAL OIL FIRED CONDENSING COMBINATION BOILER USING BALANCED FLUE SYSTEM FOR OPEN VENT AND SEALED CENTRAL HEATING SYSTEMS WITH DOMESTIC MAINS FED HOT WATER THE APPLIANCE IS FOR USE WITH KEROSENE ( 28 SECOND OIL) ONLY GB INSTRUCTION MANUAL INSTALLATION COMMISSIONING & SERVICING INSTALLATION & SERVICING INSTRUCTIONS SYMBOLS USED IN THIS MANUAL: PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION. THESE INSTRUCTIONS ARE APPLICABLE TO THE WORCESTER APPLIANCE MODEL(S) STATED ON THE FRONT COVER OF THIS MANUAL ONLY AND MUST NOT BE USED WITH ANY OTHER MAKE OR MODEL OF APPLIANCE. Domestic hot water THE INSTRUCTIONS APPLY IN THE UK ONLY AND MUST BE FOLLOWED EXCEPT FOR ANY STATUTORY OBLIGATION. Central heating THIS APPLIANCE MUST BE INSTALLED BY A COMPETENT PERSON. FAILURE TO INSTALL CORRECTLY COULD LEAD TO PROSECUTION. COMPLYING WITH THE BUILDING REGULATIONS: This heating appliance forms part of the controlled services for the building. It is law that all controlled services for buildings must comply with building regulations. You must be able to satisfy your Local Authority Building Control Body (LABC) that the work carried out concerning the installation and commissioning of this heating appliance has been carried out to a satisfactory standard. Room thermostat Frost thermostat OFTEC operate a competent persons scheme and registered installers are able to certify that their work complies with building regulations. Under the scheme; OFTEC must be informed about every installation. OFTEC will issue a building regulations compliance certificate to the householder and will notify the LABC. Wait time period OFTEC provide controlled document forms CD10 and CD11 for use during installation and commissioning respectively. Programmer/timer OFF Other organisations operate self-certification schemes e.g. NAPIT and BESCA Ltd. and it may be possible for installers who are members of these organisations to self certify their work. Alternatively you must submit a building control notice to the LABC before installing any boiler. The LABC will then arrange regular inspection visits during the work to ensure that the installation complies with the regulations. Programmer ON CH only IF YOU ARE IN ANY DOUBT CONTACT THE WORCESTER TECHNICAL HELPLINE. DISTANCE LEARNING AND TRAINING COURSES ARE AVAILABLE FROM WORCESTER. Programmer ON DHW only PLEASE LEAVE THESE INSTRUCTIONS WITH THE COMPLETED COMMISSIONING FORM AND THE USER MANUAL WITH THE OWNER OR WITH THE APPLIANCE AFTER INSTALLATION OR SERVICING. THE SERVICE INTERVAL RECORD CAN BE FOUND ON THE BACK PAGE OF THIS MANUAL. Programmer ON CH and DHW Cold water main supply Electricity supply IMPORTANT HANDLING INSTRUCTIONS: It is advised that more than one person is involved in the transfer of the packaged appliance from the van to the point of installation. It is advised that no attempt should be made to move the packaged appliance without the use of a suitable truck. At all times the correct method for handling heavy objects should be strictly observed. GENERAL HANDLING GUIDELINES: • Lift only a manageable weight, or ask for help. • When lifting, bend the knees, and keep the back straight and feet apart. • Do not lift and twist at the same time. • Lift and carry items close to the body. • Wear protective clothing and gloves to protect from any sharp edges. ABBREVIATIONS USED IN THIS MANUAL: Ø Diameter CH Central Heating DHW Domestic Hot Water TRV Thermostatic Radiator Valve IP Ingress Protection CF Conventional flue BF Balanced flue N/A Not allowed SEDBUK Seasonal Efficiency of Domestic Boilers in the United Kingdom OFTEC Oil Firing Technical Association for the Petrolium Industry IEE Institute of Electrical Engineers LABC Local Authority Building Control Body STORE THE APPLIANCE IN A DRY AREA PRIOR TO INSTALLATION. Check List Hardware/Literature pack Item Qty Greenstar Heatslave External Installation/Servicing Instructions.........1 Users Instructions............................................................................................1 Hardware Pack.................................................................................................1 100mm Ø Services Duct................................................................................1 Condensate Trap Kit........................................................................................1 Warranty Return Envelope.............................................................................1 Cabinet Key.......................................................................................................1 1 INSTALLATION & SERVICING INSTRUCTIONS INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) SAFETY & REGULATIONS CONTENTS IMPORTANT INFORMATION AND SYMBOLS 1 SAFETY PRECAUTIONS AND INSTALLATION REGULATIONS 3 APPLIANCE INFORMATION SAFETY & REGULATIONS APPLIANCE INFORMATION GENERAL INFORMATION 4 TECHNICAL DATA 5 LAYOUT & COMPONENTS 6 CLEANING PRIMARY SYSTEMS 7 MAINS SUPPLIES 8 9 WATER SYSTEMS & PIPEWORK 10-11 CONDENSATE & PRESSURE RELIEF PIPEWORK 12 BOILER LOCATION & CLEARANCES 13 CABINET MOUNTED LOW LEVEL FLUE TERMINAL POSITIONS 14 HIGH LEVEL FLUE TERMINAL POSITIONS 15 EXTERNAL OILFIT BALANCED FLUE OPTIONS 16 CABINET MOUNTED HORIZONTAL BALANCED FLUE OPTIONS 17 INSTALLATION OIL SUPPLY PRE INSTALLATION PRE-INSTALLATION INSTALLATION 18 PIPEWORK & FLUE POSITIONS 19 BOILER INSTALLATION 20 FLUE INSTALLATION 21 COMBUSTION CHAMBER 22 PIPEWORK CONNECTIONS 23-24 OIL BURNER AND PUMP 25 REFITTING COMPONENTS 26 ELECTRICS COMMISSIONING UNPACKING THE BOILER 27-28 PRE-COMMISSIONING CHECKS - APPLIANCE 29 FILLING THE SYSTEM 30 31-34 WATER TREATMENT 35 FINISHING COMMISSIONING - APPLIANCE 36 FAULT FINDING & DIAGRAMS STARTING THE APPLIANCE SERVICING & SPARES COMMISSIONING SERVICING & SPARES INSPECTION AND SERVICE 37-40 SHORT PARTS LIST 12/18 41 SHORT PARTS LIST 18/25 42 SHORT PARTS LIST 25/32 43 FAULT FINDING & DIAGNOSIS FAULT FINDING 44-45 FAULT FINDING LOGIC FOR SATRONIC CONTROL BOX 46 FAULT FINDING LOGIC FOR 535 SE/LD RDB CONTROL BOX 47 ELECTRICAL SCHEMATIC 48 COMMISSIONING & SERVICE RECORDS COMBUSTION RECORD 49 SERVICE INTERVAL RECORD 50 2 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) CONTENTS SAFETY & REGULATIONS SAFETY PRECAUTIONS INSTALLATION REGULATIONS OIL SMELLS, LEAKS OR FUMES FROM THE APPLIANCE: Extinguish any naked flames. Isolate the electrical supply. Isolate the fuel supply to the boiler. Rectify fault. HEALTH & SAFETY: The appliance contains no asbestos and no substances have been used in the construction process that contravene the COSHH Regulations (Control of Substances Hazardous to Health Regulations 1988). Where applicable, the CE mark indicates compliance with relative EU Directives. COMBUSTIBLE AND CORROSIVE MATERIALS: Do not store or use any combustible materials (paper, thinners, paints etc.) inside or within the vicinity of the appliance. The combustion air must be kept clear of chemically aggressive substances which can corrode the appliance and invalidate any warranty. FITTING & MODIFICATIONS: Fitting the appliance and any controls to the appliance may only be carried out by a competent engineer in accordance with these instructions and the relevant Installation Regulations. Flue systems must not be modified in any way other than as described in the fitting instructions. Any misuse or unauthorised modifications to the appliance, flue or associated components and systems could invalidate the warranty. The manufacturer accepts no liability arising from any such actions, excluding statutory rights. SERVICING: Advise the user to have the system regularly serviced by a competent, qualified engineer (such as OFTEC registered personnel) using approved spares, to help maintain the economy, safety and reliability of the appliance. Failure to install appliances correctly could lead to prosecution. The appliance should be installed by a competent person. The person installing the appliance should be aware of the Health and Safety at Work Act and take appropriate action to ensure that the regulations are adhered to. In order to give optimum efficiency and trouble free operation the appliance must be commissioned by a qualified OFTEC engineer. The compliance with a British Standard does not, in itself, confer immunity from legal obligations. In particular the installation of this appliance must be in accordance with the relevant requirements of the following British Standards and regulations in respect of the safe installation of equipment: BS 5410: part 1: Code of practice for Oil Fired Boilers. BS 799: part 5: Specification for Oil Storage Tanks. BS 7593: Code of Practice for treatment of water in domestic hot water central heating systems. BS 5449: part 1: Specification for forced circulation hot water central heating for domestic premises. BS 5955: part 8: Specification for the installation of thermoplastic pipes and associated fittings for use in domestic hot and cold water services and heating systems. BS 7291: Thermoplastic pipes and associated fittings for hot and cold water for domestic purposes and heating installations in buildings. BS 7074: part 1: Application, selection and installation of expansion vessels and ancillary equipment for sealed water systems. BS 7671: IEE Wiring Regulations, current edition. BS 1362: Specification for general purpose fuse links for domestic and similar purposes. The Building Regulations Part J and L1 England and Wales; Part F and Part J Section III Scotland; Part L and Part F Northern Ireland. Local water company bye-laws. The Control of Pollution (Oil) Regulations. OFTEC Standards. Where no specific instruction is given, reference should be made to the relevant codes of practice. 3 SAFETY PRECAUTIONS & INSTALLATION REGULATIONS INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) GENERAL INFORMATION STANDARD PACKAGE: 770mm 640mm A A - Floor standing oil fired condensing boiler for open vent and sealed domestic central heating and mains fed hot water. B - Literature pack. D - 100mmØ services duct. E - Cabinet key 950mm APPLIANCE INFORMATION C - Condensate trap kit. B C D E Check List Item Qty Greenstar Heatslave External Installation/Servicing Instructions........1 Users Instructions ..........................................................................................1 100mm Ø Services Duct...............................................................................1 Condensate Trap Kit.......................................................................................1 Warranty Return Envelope ............................................................................1 Cabinet Key.......................................................................................................1 4 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) GENERAL INFORMATION TECHNICAL DATA DESCRIPTION UNITS 12/18 18/25 25/32 Central Heating APPLIANCE INFORMATION Primary water capacity (total) litres 69 69 72 Maximum static head metres 30 30 30 Minimum static head metres 1 1 1 metres water 4.7 4.0 4.2 bar 2.5 2.5 2.5 colour Lime — — litres/min 15 18 22 Minimum inlet pressure (dynamic) for optimum flow rate bar 1.5 1.2 0.9 Maximum hot water rise for 90 litres draw off (@optimum flow rate) °C 40 40 40 kg/hr 29 40 51 Available pump head (20°C difference) at max. output Max. permissible sealed system operating pressure in accordance with WRAS guidelines Flow restrictor Domestic Hot Water Optimum flow rate (±15%) Flue Exit flue gas mass flow Pipework connections Fuel line (compression) mm 10 10 10 CH flow mm 22 22 28 CH return mm 22 22 28 Water main inlet mm 15 15 15 DHW outlet mm 22 22 22 Open vent (optional) BSP 1 1 1 CH drain/optional feed and expansion BSP 3/ 3/ 3/ Condensate (polypropylene) mm 21.5 21.5 21.5 AC...V 230 230 230 Frequency Hz 50 50 50 Max. power consumption W 240 240 263 CH control thermostat range (cut in/cut out) °C 55/81 55/81 55/81 DHW control thermostat range (cut in/cut out) °C 55/72 55/72 55/72 CH & DHW control thermostat differential °C 5 5 5 Boiler high limit thermostat set point °C 92 92 92 Boiler manual reset overheat thermostat set point °C 105 105 105 Flue reset overheat thermostat set point °C 110 110 110 °C <100 <100 <100 SEDBUK (Band A) % 90.2 90.1 90.3 Appliance protection rating IP 45 45 45 Weight (excluding packaging) kg 195 195 206 class 3 3 3 mg/kW hr 75 70 75 4 4 4 Electrical Electrical power supply voltage Thermostats General Data Maximum hearth temperature Emissions class for NOx and CO Typical NOx emissions figure 5 TECHNICAL DATA INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) LAYOUT & COMPONENTS The diagram opposite excludes the top, front and RH side casing panels. 44 43 i) 44 iii) ii) 43 i) 42b v) ii) iii) iv) 13 v) 42a 18 14 12 10 15 11 16 8 9 4 5 6 17 7 19 3 1 41 40 2 39 38 37 35/36 34 33 32 20 21 31 30 26 29 25 24 23 22 27 28 CONTROL BOX ASSEMBLY DIVERTER VALVE PRESSURE GAUGE AUTO AIR VENT CH CONTROL AND MANUAL RESET OVERHEAT THERMOSTAT PHIAL 6. CASING SIDE PANEL 7. CIRCULATING PUMP 8. AUTO-RESET HIGH LIMIT THERMOSTAT PHIAL 9. DHW FLOW SWITCH 10. PRESSURE RELIEF VALVE 11. DHW HEAT EXCHANGER 12. FLUE GAS SAMPLING POINT 13. FLUE OVERHEAT THERMOSTAT PHIAL 14. CASING SUPPORT PANEL 15. FLUE MANIFOLD ACCESS COVER 16. AIR INLET PIPE AND CASING 17. SECONDARY HEAT EXCHANGER BLEED POINT (ONE ON EITHER SIDE) 18. SECONDARY HEAT EXCHANGER 19. SECONDARY HEAT EXCHANGER DRAIN 20. EXPANSION VESSEL 21. OPTIONAL OPEN VENT/AIR VENT 22. DRAIN AND OPTIONAL FEED AND EXPANSION 23. CONDENSATE OUTLET 24. PRIMARY HEAT EXCHANGER 25. TRAY 26. OIL ISOLATION VALVE 27. CONDENSATE TRAP 28. CONDENSATE TRAP BRACKET 29. COMBUSTION CHAMBER ACCESS DOOR 30. HEATSLAVE TANK DRAIN 31. HEATSLAVE TANK 32. MODE SWITCH 33. BOILER MODE INDICATOR 34. LOCKOUT INDICATOR 35. OVERHEAT RESET BUTTONS (boiler & flue temperature) 36. LOCKOUT RESET BUTTON 37. SERVICE CONNECTION 38. CH TEMPERATURE CONTROL 39. DHW TEMPERATURE CONTROL 40. DATA LABEL 41. FROST THERMOSTAT SENSORS 42a. B E NTO N E STE R LI N G B U R N E R (12/18 & 18/25) i) CONTROL BOX ii) MOTOR iii) AIR INTAKE CASING iv) OIL PUMP v) COMBUSTION HEAD APPLIANCE INFORMATION iv) 1. 2. 3. 4. 5. 42b. RIELLO RDB 2.2 BURNER (25/32) i) CONTROL BOX ii) MOTOR iii) AIR INTAKE CASING iv) OIL PUMP v) COMBUSTION HEAD 43. CLIP - AIR INTAKE HOSE 44. AIR INTAKE HOSE 6 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) LAYOUT & COMPONENTS CLEANING PRIMARY SYSTEMS IMPORTANT: All the following Pre-Installation sections must be read and requirements met before starting boiler or flue installation. CAUTION: ISOLATE THE MAINS SUPPLIES BEFORE STARTING ANY WORK AND OBSERVE ALL RELEVANT SAFETY PRECAUTIONS. IMPORTANT: Debris from the system can damage the boiler and reduce efficiency. Failure to comply with the guidelines for t he use of wat er treatment with the appliance will invalidate the appliance warranty. BEFORE CLEANING THE SYSTEM: ENSURE THE SYSTEM AND PIPEWORK IS IN GOOD WORKING ORDER. PRE INSTALLATION FLUSH THE EXISTING SYSTEM WITH A POWER FLUSHING MACHINE OR WITH A CHEMICAL CLEANER BEFORE INSTALLING NEW COMPONENTS. CLEANING THE PRIMARY SYSTEM: Cleanse the system in accodance with BS 7593. Fill the system with cold mains water to the recommended pressure and check for leaks. Open all drain cocks and drain the system. Close drain cocks and add a suitable flushing agent at the correct strength for the system condition in accordance with the manufacturer's instructions. Circulate the flushing agent before the boiler is fired up. Run the boiler and system at normal operating temperature in accordance with the manufacturer's instructions. Drain and thoroughly flush the system to remove the flushing agent and any debris. 7 CLEANING PRIMARY SYSTEMS INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) IMPORTANT: The appliance provides a permanent external electrical supply for servicing and must therefore be fed via a circuit breaker incorporating earth leakage protection. MAINS SUPPLIES ELECTRIC SUPPLY: • Supply: 230V - 50Hz. • Cable: PVC insulated 0.75mm2 (24 x 0.2mm) temperature rated to 90°C. • Protection IP45. • External 5A fuse to BS 1362. • The appliance must be earthed. • Please refer to IEE regulations for cross bonding requirements. • Wiring between the appliance and the electrical supply must comply with IEE wiring regulations and any local regulations which may apply for fixed wiring to a stationary appliance. • Any system connected to the boiler must not have a separate electrical supply. PRE INSTALLATION • It must be possible to isolate the appliance from the electric supply with at least a 3mm contact separation in both poles supplying the appliance. WATER SUPPLY: The following are general requirements and if necessary the advice of the local water company should be sought before fitting the appliance. • The appliance cold water supply should be the first connection off the water main where possible. Water Mains Pressure: Minimum dynamic mains water pressure for optimum performance. MAINS WATER EXPANSION VESSEL: A - Mini expansion vessel, part No. 7 716 102 105 B - Mains water inlet C - Non-return valve D - Boiler D A B 12/18kW 18/25kW 25/32kW 1.5 bar 1.2 bar 0.9 bar • Maximum mains fed water pressure 10 bar. If necessary, fit a pressure reducing valve. IMPORTANT: Non-return, back flow prevention devices (including those associated with water meters) fitted to the mains water supply can cause a pressure build up which could damage the boiler and other household appliances. C • Where the water main supply has a nonreturn, back flow prevention valve fitted, a mini expansion vessel (A) must be connected to the mains water inlet pipe (B) between the non-return valve (C) and the boiler (D) as shown opposite. Use in hard water areas: Normally there is no need for water treatment to prevent scale formation as the maximum temperature of the heat exchanger is limited by the control circuit. In areas where the temporary water hardness exceeds 200ppm, consideration may need to be given to the fitting of a scale prevention device. In such circumstances, the advice of the local water authority should be sought. 8 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) MAINS SUPPLIES A B C D E F G H J K L M N - Oil storage tank - Isolating valve - Oil strainer & water seperator - Fire valve to BS5410 - External casing - Fire valve sensor - Oil burner OIL SUPPLY - Oil supply pipe - Oil pump - Full base (plastic tanks) - Non-return valve - De-aerator - Oil filter (16µm max filtration size) This appliance is suitable for kerosene (28 second oil) only, no other fuel must be used. OIL SUPPLY: • Plastic or steel tanks should be installed to BS 5410. A steel tank should conform to BS 799: part 5 and have a slope of 1 in 24 away from the outlet valve with a sludge cock at its lower end. • Do not use galvanised steel tanks or pipework for the oil supply system. • Do not use soldered joints on the oil supply pipework. NOTE: All dimensions are in metres unless stated otherwise. The maximum pipe run figures are based on using copper pipe with an inside diameter of 2mm less than the Ø. . 1m min F B C H BD BN G J MAXIMUM PIPE RUN FOR SINGLE PIPE GRAVITY FEED SYSTEM HEAD 0.5 1.0 1.5 2.0 10mmØ 12 25 37 49 12mmØ 30 69 91 100 HEAD 2.5 3.0 3.5 4.0 10mmØ 62 74 87 99 c) Single pipe suction lift with de-aerator Maximum suction height 3.5 metres. The oil tank (A) must be positioned below the oil pump (J). Create an inlet and return loop between the de-aerator (M) and oil pump (J). . 1m min F G b) B D L A B C L B H J N 150mm K E MAXIMUM PIPE RUN FOR DOUBLE PIPE SUB-GRAVITY FEED SYSTEM 10mmØ 50 44 38 32 12mmØ 100 100 95 80 HEAD 2.0 2.5 3.0 3.5 10mmØ 26 20 14 8 c) A H B J D 1m min K . E MAXIMUM PIPE RUN FOR SINGLE PIPE SUCTION LIFT WITH DE-AERATOR HEAD 0 0.5 1.0 1.5 FUEL FLOW RATE 2.5kg/h 5kg/h 10kg/h 10kg/h 8mmØ 8mmØ 8mmØ 10mmØ 100 55 26 100 95 45 23 100 80 40 20 90 70 35 17 75 HEAD 2.0 2.5 3.0 3.5 A top feed oil tank fitted with a de-aerator using an internal non-return valve should have any non-return valves fitted in the base of the tank to the suction line removed to assist purging air from the oil line. Lay the oil supply pipe (H) as straight and level as possible to avoid air pockets and unnecessary friction losses. Route away from the boiler access door or other hot surfaces. F G M B C A non-return valve must be incorporated within the de-aerator or fitted to the oil line between the oil storage tank (A) and the de-aerator (M). Pipework Use copper pipe of the correct diameter according to the information shown opposite. Use flexible hoses to connect to the oil pump (J). 12mmØ 66 50 37 22 3.5m (11.5ft) max. HEAD 0 0.5 1.0 1.5 a) Single pipe gravity feed system: The oil storage tank (A) must be positioned so that the oil level does not exceed 4 metres above the level of the burner oil pump (J) and in addition the oil level must be at least 300mm above the oil pump (J). Where the maximum oil level in the oil storage tank exceeds 4 metres, a head breaking device must be installed between the tank (A) and the burner oil pump (J). b) Double pipe sub-gravity feed system: Maximum suction height 3.5 metres. Non-return valves must be fitted to the inlet and return oil line between the oil pump (J) and oil storage tank (A). E 12mmØ 100 100 100 100 3.5m (11.5ft) max. PRE INSTALLATION K 4m (13ft) max. A 300mm min. a) FUEL FLOW RATE 2.5kg/h 5kg/h 10kg/h 10kg/h 8mmØ 8mmØ 8mmØ 10mmØ 60 30 14 65 45 25 11 50 35 15 8 35 25 10 5 20 The table and illustration above is a guide only and does not in any way override the deaerator manufacturers instructions. Install a manual isolating valve (B) to the oil supply pipe (H), as close to the oil storage tank (A) as possible. Fit an oil strainer and water seperator (C) to the oil supply pipe, near the oil storage tank. Fit an additional oil filter (N, 16µm max filtration size) close to the boiler, but not inside the boiler casing. Fit a fire valve in accordance with BS 5410. The fire valve (D) must be fitted externally at least 1 metre from the appliance with the fire valve sensor (F) located within the appliance case. A capillary type valve provides a neat and simple installation. Alternatively, a fusible link or electrical system may be used. Under no circumstances should a combination isolating/fire valve be used as the sole fire protection device. 9 OIL SUPPLY INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) WATER SYSTEMS & PIPEWORK IMPORTANT: The boiler should not be allowed t o operat e wit h a ret urn temperature of less than 40°C when the system is up to operating temperature. PRIMARY SYSTEM PLASTIC PIPEWORK: • Plastic pipework used for underfloor heating must be correctly controlled with a thermostatic blending valve limiting the temperature of the circuits to approx. 50°C with 1000mm (minimum) length of copper or steel pipe connected to the boiler. TYPICAL OPEN VENT SYSTEM 1000mm min. F INSTALLATION PRIMARY SYSTEM/CONNECTIONS/VALVES: S E • Do not use galvanised pipes or radiators. H R T R L T • Radiator valves should conform to BS 2767:10. L • All other valves should conform to BS 1010. G R L COMMISSIONING • All system connections, taps and mixing valves must be capable of sustaining a pressure of 3 bar. PRE INSTALLATION • Plastic pipework must not be used for the DHW system. • Any plastic pipework used for the CH system must have a polymeric barrier, comply with BS 7921 and installed to BS 5955 with 1000mm (minimum) length of copper or steel pipe connected to the boiler. • On new installations TRVs must be used on all radiators except the radiator where the room thermostat is sited, this must be fitted with lockshield valves and left open. All installations should have TRVs fitted to radiators within the sleeping accommodation. R L T L C D A - Appliance expansion vessel B - Extra expansion vessel C - Automatic bypass valve D - Drain cock E - Feed & expansion cistern D F - Feed & expansion 15mmØ min G - Appliance H - Open vent 22mmØ min L - Lockshield valve P - Pressure relief discharge R - Radiators S - Static head T - TRV U - To filling system T • Drain cocks are required at all the lowest points on the system. • Air vents are required at all high points on the system. OPEN VENT PRIMARY SYSTEM: R TYPICAL SEALED SYSTEM • In order to comply with BS 5449 the feed and expansion pipe and the open vent pipe, (or the combined feed and vent pipe), must be connected to the BSP outlet/s on the right hand side of the primary heat exchanger. R L T • The feed and expansion cistern (E) must be positioned to provide a static head (S) of at least 1 metre above the highest point in the heating system to the water level in the feed and expansion cistern (E). L A R G P • Ensure adequate space is left in the expansion cistern for expansion of the system water. R B L L • An automatic bypass valve must be connected between the heating flow and return where TRVs are used on all radiators, fitted to give at least a 3m circuit when activated. T • No valve shall be fitted in the open vent pipe (H) or the feed and expansion pipe (F). L • The open vent pipe (H) must be at least 22mmØ. U C SEALED PRIMARY SYSTEM: D D • Where the system volume is more than 180 litres at 0.5 bar or exceeds 2.65bar at maximum heating temperature an extra expansion vessel (B) must be fitted as close as possible to the appliance in the central heating return. • Pressurise the extra expansion vessel (B) to the same figure as the expansion vessel built into the appliance. 10 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) WATER SYSTEMS & PIPEWORK WATER SYSTEMS & PIPEWORK Water main supply Heating return Hose return Non return Non return valve valve Stop cock Temporary hose Test cock Stop cock FILLING PRIMARY SEALED SYSTEMS: • Filling the system must comply with one of the methods shown opposite. • The filling point must be at low level and must never be a permanent direct fixing to the mains water supply. • Filling loops must be WRAS approved. SHOWERS/BIDETS: Heating return Make up vessel Auto air vent PRE INSTALLATION Non return valve Stop cock Fill Point 1000mm above the highest point of the system • If a shower head can be immersed in water or comes closer than 25mm from the top edge of a bath or shower tray spill over level then an anti-siphon device must be fitted to the shower hose. • Only thermostatically controlled showers are suitable for use with this appliance. • Bidets with direct hot & cold mains water can be used (with the approval of the local water authority) and must be the over rim flushing type with shrouded outlets to prevent the fitting of hand held sprays. DOMESTIC HOT WATER: INSTALLATION • Plastic pipework must not be used for the DHW system. • Taps and mixing valves must be capable of sustaining a pressure up to 10 bar in accordance with the Water Regulations as they will be operating at mains water pressure. COMMISSIONING • Hot water temperature and flow rate are affected by the size and insulation of pipework making up the distribution system and are controlled by the hot water tap and the water main inlet pressure. A mixing valve can be fitted if a more permanent setting is required. • If using more than one outlet at once causes water flow starvation, fit flow balancing valves or Ball-O-Fix valves to the appropriate outlets. 11 WATER SYSTEMS & PIPEWORK INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) CONDENSATE & PRESSURE RELIEF PIPEWORK a C CONDENSATE PIPEWORK: A D 75mm min. b • The condensate pipework must fall at least 50mm per metre towards the outlet and should take the shortest practicable route and not exceed 3 metres outside the building. If a run greater than 3m is required, 32mmØ polypropylene pipe must be used. c C E C A • All national and, where appropriate, local regulations for the discharge and neutralisation of condensate should be followed. • The condensate pipe must be a minimum of 21.5mmØ polypropylene pipe. 450 min. A D • The pipework must follow one of the options shown opposite: a - Internal waste drainage system Invert b - Soil/vent stack c - External drainage system d (Unsuitable for clay soil types) C d - External condensate absorption point 500mm min. • Condensate pipework must not be connected to rainwater downpipes. F A PRE INSTALLATION B 25mm min. G I H 400mm min. • Use waterproof pipe insulation in exposed positions and for external pipework IMPORTANT: Condensate pipework must not leak and the condensate trap must be filled with water before the boiler is started to prevent the possibility of potentially harmful flue products escaping via the condensate route. A - Condensate from the boiler condensate trap (supplied) which has a 75mm minimum water seal. 200mm min. B - Sink. C - 21.5mm Ø polypropylene condensate pipe. D - Gully. E - Internal soil and vent stack. F - 300mm x 100mm Ø sealed plastic tube. G - Ground level. H - Drainage holes 50mm from base of tube (12mm Ø at 25mm centres) facing away from building. I- Limestone chippings. PRESSURE RELIEF PIPEWORK: J K IMPORTANT: The pressure relief valve is a safety device for the boiler and if activated may discharge boiling water or steam through the relief valve drain pipe. Care should be taken when siting the outlet pipe so that it does not cause an obstruction or discharge above a window, entrance or other public access where it could cause a hazard. • The pressure relief drain pipe (K) should be at least 15mm diameter copper pipe and run downwards away from the boiler and discharge away from any electrics or other hazard, preferably to an external drain or soakaway. • Pipe (K) should be finished with a partial bend, near the outlet to face the external boiler casing (as shown) to help prevent freezing. J - External boiler casing. K- Pressure relief pipe. 12 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) CONDENSATE & PRESSURE RELIEF PIPEWORK BOILER LOCATION & CLEARANCES 600mm WARNING: This appliance should not be installed where there is a potential for excessive ground water coverage. 2500mm* FRONT 600mm This boiler is only suitable for installing externally at a suitable location onto a fixed permanent rigid surface c apable of supporting the boiler weight. There must be a sufficient hard standing around the appliance to allow for servicing. The boiler must be installed on a flat level surface to ensure that condensate does not enter the primary heat exchanger. PRE INSTALLATION Tarmac and wood hardstandings are not recommended. 600mm (min) BASE CLEARANCES: Min service & flue clearances Above 600mm Front 600mm 2500mm* RH/LH flue outlet on opposite side RH flue outlet on rear LH flue outlet on rear Rear = flue outlet on side Rear = rear flue outlet 10mm Plan view 10mm 85mm 10mm 150mm** 2500mm* It is strongly recommended that the flue terminal faces away from walls to reduce the possibility of wetting occuring. 85mm *This can be reduced to 1200mm if there is at least 2500mm clearance on both sides of the flue. FRONT ** 200mm if a high level terminal is used exiting through the rear panel. 600mm 150mm** 150mm** 10mm 2500mm* 2500mm* 10mm Plan view Plan view FRONT FRONT 600mm 600mm 13 BOILER LOCATION & CLEARANCES INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) CABINET MOUNTED LOW LEVEL Minimum dimensions of flue terminal positions for oil fired appliances: FLUE TERMINAL POSITIONS TERMINAL POSITION B(H) • Flue terminals must be positioned to avoid combustion products entering into buildings. A 1 Directly below an opening, air brick, opening windows, etc 600mm B 1 Horizontally to an opening, air brick, opening window, etc 600mm C Below a plastic/painted gutter, drainage pipe or eaves if combustible material protected 75mm D2 Below a plastic/painted gutter, drainage pipe or eaves without protection to combustible material 600mm E From vertical sanitary pipework 300mm F From an external or internal corner or from a surface or boundry alongside the terminal 300mm G Above ground or balcony level 300mm* H1 From a surface or boundary facing the terminal with 2500mm clearance to both sides of the terminal 1200mm H2 From a surface or boundary facing the terminal with less than 2500mm clearance to either side of the terminal 2500mm I1 From a terminal facing the terminal with 2500mm clearance to clearance to both sides of the terminal 1200mm I2 From a terminal facing the terminal with less than 2500mm clearance to either side of the terminal 2500mm Horizontally from a terminal 750mm K • The flue must be fitted and terminated in accordance with the recommendations of BS5410. • The flue must not cause an obstruction. • Discharge from the flue outlet must not be a nuisance. • There should be no restriction preventing the clearance of combustion products from the terminal. • The air inlet/outlet duct and the terminal of the boiler must not be closer than 25mm to any combustible material. Detailed recommendations on protection of combustible materials are given in BS 5410:1 PRE INSTALLATION • Flue gases have a tendency to plume and in certain weather conditions a white plume of condensation will be discharged from the flue outlet which could be regarded as a nuisance, for example, near security lighting. • A protective terminal guard must be fitted if the terminal is 2m or less above a surface where people have access. Stainless steel terminal guard. Part No: 7 716 190 050 • The following additional guidelines (from part L Exceptions Guidance Document) are recommended when determining the flue outlet position: B(H) Balanced Horizontal flue • Avoid discharging flue gases into car ports or narrow passageways. 1 An opening means an openable element, such as an openable window, or a permanent opening such as a permanently open air vent. • *Minimum distance of the flue terminal from above ground is 2100mm where directed to a public footpath, private access route or a frequently used area and 2500mm from a car parking area. Notwithstanding the dimensions above, a terminal should be at least 300mm from combustible material, e.g. a window frame. 2 A way of providing protection of combustible material would be to fit a heat shield at least 750mm wide. boundary C, D F I A H B F E J F G K boundary 14 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) CABINET MOUNTED LOW LEVEL FLUE TERMINAL POSITIONS Minimum dimensions of flue terminal positions for oil fired appliances: TERMINAL POSITION B(V) POSITIONS A1 2 Directly below an opening, air brick, opening window, etc 600mm N/A B1 2 Horizontally to an opening, air brick, opening window, etc 600mm N/A 75mm N/A Below a plastic/painted gutter, drainage pipe or eaves without protection to combustible material 600mm N/A E From vertical sanitary pipework 300mm N/A F From an external or internal corner or from a surface or boundry alongside the terminal 300mm N/A G Above ground or balcony level 300mm* N/A H From a surface or boundary facing the terminal 600mm** N/A J From a terminal facing the terminal 1200**mm — C D3 PRE INSTALLATION HIGH LEVEL FLUE TERMINAL B(H) Below a plastic/painted gutter, drainage pipe or eaves if combustible material protected Vertically from a terminal on the same wall 1500mm N/A L Horizontally from a terminal on the same wall 750mm — M Above the point of highest intersection with the roof — 600mm N From a vertical structure on the side of the terminal — 750mm O Above a vertical structure less than 750mm from the side of the terminal — 600mm — — — 300mm — 1000mm Q R From a ridge terminal to a vertical structure on the roof Above or to the side of any opening on a flat or sloping roof Below any opening on a sloping roof • The flue must be fitted and terminated in accordance with the recommendations of BS 5410. • The flue must not cause an obstruction. K P • Flue terminals must be positioned to avoid combustion products entering into buildings. • Discharge from the flue outlet must not be a nuisance. • Flue gases have a tendency to plume and in certain weather conditions a white plume of condensation will be discharged from the flue outlet which could be regarded as a nuisance, for example, near security lighting. • There should be no restriction preventing the clearance of combustion products from the terminal. • The air inlet/outlet duct and the terminal of the boiler must not be closer than 25mm to any combustible material. Detailed recommendations on protection of combustible materials are given in BS 5410:1 • A protective terminal guard must be fitted if the terminal is 2m or less above a surface where people have access. The guard must be spaced equally (minimum 50mm) around the flue and fixed to the wall with plated screws. Stainless steel terminal guard. Part No: 7 716 190 050 Key: — Not applicable, N/A Not allowed, B(H) Balanced Horizontal flue, B(V) Balanced Vertical flue. Notes: 1. Terminals should be positioned so as to avoid products of combustion accumulating in stagnant pockets around the building or entering into buildings. 2. Vertical structure in N, O and P includes tank or lift rooms, parapets, dormers etc. 3. Terminating positions should be at least 1.8m from an oil storage tank unless a wall with at least 30 min fire resistance and extending 300mm higher and wider than the tank is provided between the tank and the terminating position. 4. Where a flue is terminated less than 600mm away from a projection above it and the projection consists of plastics or has a combustible or painted surface, then a heat shield of at least 750mm wide should be fitted. 5. If the lowest part of the terminal is less than 2m above the ground, balcony, flat roof or other place to which any person has access, the terminal should be protected by a guard. 6. Notwithstanding the dimensions given above, a terminal should not be sited closer than 300mm to combustible material. In the case of a thatched roof, double this separation distance should be provided. It is also advisable to treat the thatch with a fire retardant material and close wire in the vicinity of the flue. 7. It is essential that a flue or chimney does not pass through the roof within the shaded area delineated by dimensions Q and R. 8. Where protection is provided for plastic components, such as guttering, it is essential that this is to the standard specified by the manufacturer of the plastic components. The following additional guidelines (from part L Exceptions Guidance Document) are recommended when determining the flue outlet position: • Avoid discharging flue gases into car ports or narrow passageways. • *Minimum distance of the flue terminal from above ground is 2100mm where directed to a public footpath, private access route or a frequently used area and 2500mm from a car parking area. • **Minimum distance of the flue terminal to a facing wall, fence, building or property boundary is 2500mm. P Q Q Q Q Q Q O M boundary R F N Pitched roof C, D J A H B F E K F G boundary 15 HIGH LEVEL FLUE TERMINAL POSITIONS Q Flat roof INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE 12/18-18/25-25/32 8 716 106 252d (08/07) L BALANCED EXTERNAL OILFIT L = 2000mm FLUE OPTIONS IMPORTANT: The weather seal (supplied) must be fitted to every flue joint to give the required level of weather protection. L F * B The diagrams (opposite) show the components used and the maximum flue length (L) for each flue configuration. 125mmØ x2 ** High level horizontal terminal (rear outlet) In all cases L is measured from the outside of the boiler casing. • To achieve the maximum flue length (L), a flue section will have to be reduced in length. IMPORTANT: All horizontal sections must rise away from the boiler by 52mm per metre (3°) to allow the condensate to drain back to the boiler. L = 7000mm L A C E D F PRE INSTALLATION • Only the straight flue extensions can be reduced in length by cutting. E B B 125mmØ x5 ** Vertical terminal (rear outlet) A - Horizontal terminal B - Straight flue extension C - Flue bend 90° D - Flue bend 45° E - Vertical Terminal Kit (incl. 90° elbow) F - Horizontal terminal kit (incl. 90° elbow) Calculating the flue length: L = 6000mm Measure the total flue length required, noting that the maximum straight flue length including the terminal is: Horizontal 80/125mmØ: 4000mm. Vertical 80/125mmØ / 100/150mmØ (25/32 only): 7000mm. L Then reduce the total straight flue length for each extra flue bend (excluding the vertical flue kit 90° elbow) by: D E 1000mm for 90° D 500mm for 45° B Flue Extension lengths: 125mmØ x4 Horizontal & Vertical: 1000mm overall length. ** Vertical terminal (rear outlet) Effective length when engaged into sockets within the flue run is 950mm. Flue Terminal lengths: Horizontal 80/125mmØ: 720mm Vertical 80/125mmØ: 1080mm + cage * Rear exit only. ** Horizontal flue runs should be kept as short as possible. L = 6000mm L E C B 125mmØ x4 ** Vertical terminal (side outlet) 16 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) BALANCED EXTERNAL OILFIT FLUE OPTIONS CABINET MOUNTED BALANCED HORIZONTAL FLUE OPTIONS • The horizontal flue is fitted to the rear or either side of the cabinet. REAR FLUE OUTLET A+C IMPORTANT: It is strongly recommended that the flue terminal faces away from walls to minimise the occurance of wetting. PRE INSTALLATION Plan view FRONT A - External horizontal flue kit Part No. 7 716 190 052 LEFT HAND FLUE OUTLET A+B+C B - 90° inline elbow 80/125mm Part No. 7 716 190 034 Plan view C - Terminal guard Part No. 7 716 190 050 FRONT RIGHT HAND FLUE OUTLET A+B+C Plan view FRONT 17 BALANCED FLUE OPTIONS INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) IIMPORTANT: All the previous Pre-Installation sections must be read and requirements met before starting boiler or flue installation. UNPACKING THE BOILER LIFTING AND CARRYING PRECAUTIONS: • Lift only a manageable weight, or ask for help. 1 • When lifting or putting things down, bend the knees, and keep the back straight and feet apart. • Do not lift and twist at the same time. • Lift and carry objects close to the body. • Wear protective clothing and gloves to protect from any sharp edges. 1 Once the packaged boiler has been delivered, the outer carton is removed first. Care should be taken when releasing the straps. If a sharp implement is used make sure the outer carton is not pierced and that the implement is used in such a way so that it may not cause personal injury. All sharp objects must be covered or the blade retracted after use and put away in a safe place. 2 Lift carton up and away from the boiler. Remove the plastic bag from the boiler and place safely aside. INSTALLATION Unpacking: It is advised that two or more persons are involved in the transfer of the packaged boiler from the van to the point of delivery. 2 18 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) UNPACKING THE BOILER All dimensions in mm 256 374 PIPEWORK & FLUE POSITIONS Flue CAUTION: Ensure there are no pipes, electric cables, damp proof courses or other hazards before drilling. 171 Services 58 SAFETY: All relevant safety precautions must be undertaken. Protective clothing, footwear, gloves and safety goggles must be worn as appropriate. 802 Condensate 650 PRV PIPEWORK CONNECTIONS: 258 CH flow 22mmØ copper (28mmØ on 25/32kW model) 105 81 Fire valve capillary & drain access DHW flow 22mmØ copper REAR Mains water inlet 15mmØ CH return 22mmØ copper (28mmØ on 25/32kW model) Optional open vent 1'' BSP Services duct 100mmØ Drain/optional fill/feed & expansion 3/4'' BSP Pressure relief pipe 15mmØ 161 670 COMMISSIONING INSTALLATION 518 Condensate outlet 21.5mmØ Flue NOTE: For servicing purposes, keep the condensate and pressure relief discharge pipes away from components and pipework connections. Services 787 Condensate 650 528 269 230 PRV Oil 105 94 55 658 669 705 715 RIGHT HAND SIDE Fire valve capillary & drain access 670 518 Flue Services 794 Condensate 650 PRV Oil 158 124 89.5 55 658 679 698 718 LEFT HAND SIDE 19 PIPEWORK & FLUE POSITIONS INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) WARNING: THIS APPLIANCE IS SERVICED AND REPAIRED EXTERNALLY. BOILER INSTALLATION EXTERNAL EQUIPMENT OPERATED AT 230V SHOULD NOT BE INSTALLED, SERVICED OR REPAIRED UNDER ADVERSE WEATHER CONDITIONS. THIS APPLIANCE IS INSTALLED AND SERVICED EXTERNALLY TO THE PROPERTY, BUT THE ENGINEER MUST HAVE ACCESS TO THE INSIDE OF THE PROPERTY WHEN INSTALLING OR SERVICING THE APPLIANCE. Note: The cabinet is not load bearing it only provides weather protection for the boiler inside. 1Mark position of the 100mm services duct on the exterior wall and make a hole through. 2Remove the key for the door fastners from its transport position in the left hand side panel flue outlet aperture. Undo the screws at the bottom of the front panel (using the key provided) and remove the screws from the rear panel pulling both panels out and down to remove. Store safely away from the installation point. 7 3Remove the screws from the top panel and lift up to remove, store safely away from the installation point. C 5Remove the screws securing the control box to the side panels and carefully rest the control box on top of the heat exchanger taking care not to snag or kink the capillaries. 3 4 6Remove the screws securing the side panels to the base panel and lift the side panels off complete with the rear support bar (shaded grey) and carefully stand the panels away from the installation point. 5 INSTALLATION 4Slide the pressure gauge up out of its bracket and carefully rest on top of the heat exchanger taking care not to snag or kink the capillary. B 7Loosen the flexable air duct clamp (A) and remove the air duct from the burner. Depress the locking ears to unplug the burner lead (B) from the control box (C). 2 Unscrew the burner retainers (D), then withdraw the burner (E) from the boiler and store safely away from the installation point. 6 8Remove the screws securing the base panel to the transit pallet and lift the boiler off the pallet and into its installation position taking care not to scrape the base panel across the hard standing. Do not attempt to lift and position the boiler on your own. Do not use the copper pipes to move the boiler. Fasten the base to the hard standing using the holes provided. Care should be taken to ensure that the base is level. 8 2 9Refit the side panels and rear support bar and screw the side panels to the baseplate and boiler. E D 7 A Refit the control box and pressure gauge taking care not to kink the capillary tubes. Measure the 100mmØ services duct to give at least 10mm inside the casing and to finish flush with the interior wall surface, cut to size and fit the duct. Fit the 100mm sealing ring where the duct enters the casing and seal the joint to the exterior wall and inside the cabinet with a suitable sealant. 20 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) BOILER INSTALLATION FLUE INSTALLATION INSTALLATION NOTES: Ensure all the seals are in good condition and seated properly. To ease assembly of flue components, grease seals lightly with the solvent free grease supplied. A terminal guard must be fitted if the terminal is 2m or less above a surface where people have access. INSTALLATION All flue options: 1 Lightly grease the flue cowl seal with the solvent free grease supplied. 2 Carefully remove the blanking plate from the appropriate flue aperture (if necessary) and refit the blanking plate in the unused aperture. 3 Carefully remove the insulation from the flue aperture in the cabinet that the flue is to pass through, and fit to the unused aperture (if necessary). 4 Refer to the flue manual supplied with the flue kit for flue installation. 21 FLUE INSTALLATION INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) COMBUSTION CHAMBER F E Combustion chamber: 1 Release retaining nuts and washers (B). Remove combustion chamber access door (A). 4 2 Ensure the baffles (C) and baffle retainer (D) are correctly fitted for the boiler output as shown in the plan views opposite. A 3 Refit combustion chamber door (A). Secure with nuts and washers (B) and tighten until the door is firmly secured, do not over tighten the nuts. B 4 Unscrew screws (E) and remove flue manifold access cover (F). 5 Check that all the baffles (G) and baffle retainer (H) or ( J ) are correctly fitted to the secondary heat exchanger. 2 3 1 INSTALLATION 5 G or H J Plan sectional view Plan sectional view 12/18 & 18/25kW 25/32kW C C Hook the retainer ( J ) over the end two baffles D FRONT D FRONT 22 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) COMBUSTION CHAMBER CAUTION: ISOLATE THE OIL & WATER MAINS SUPPLY BEFORE STARTING ANY WORK AND OBSERVE ALL RELEVANT SAFETY PRECAUTIONS. PIPEWORK CONNECTIONS A B C D E F G N O P - CH flow 22mmØ copper (28mmØ on 25/32 models) DHW flow 22mmØ Water main inlet 15mmØ CH return 22mmØ copper (28mmØ on 25/32 models) 10mmØ oil supply pipe connection Oil isolating valve (10mmØ) Flexible oil hose Optional open vent/air vent Drain/optional feed and expansion Fixing point for optional return oil pipe WATER CONNECTIONS: All service pipes into the property must pass through the services duct. Insulate all the system/supply pipes where the pipes pass through the duct with at least 22mm insulation around the pipes. Remove the transit bungs from the pipework connections on the boiler. NOTE: that surplus water may be present due to factory testing. INSTALLATION Ensure all pipework is clean. Align water pipework through the 100mm Ø duct and connect, ensuring that the expansion tank and control box fit correctly before permanently connecting the pipework. Check that all unused sockets have been capped. OIL SUPPLY CONNECTIONS: NOTE: Oil filters and de-aeration devices are not to be fitted within the casing and the fire valve body must be at least 1 metre from the external casing. Route the oil supply pipe through the appropriate casing hole as required and connect to the isolating valve (F) and ensure the valve is closed. Connect the flexible oil hose (G) to the isolating valve (F). Pass the fire valve sensor through the most appropriate casing hole and locate the capillary in the cut out at the bottom of the hole. Clip the sensor into the clip provided at the rear of the control box. Rotate the cover plate and seal so it does not cover the capillary, then secure with the screws provided. 23 PIPEWORK CONNECTIONS INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) PIPEWORK CONNECTIONS - Flue manifold condensate outlet Condensate outlet (21.5mmØ) - supplied Condensate pipe - not supplied Condensate trap with clamp - supplied Pressure relief (15mmØ) CONDENSATE CONNECTION: The condensate trap (L) must be installed onto the bracket supplied. Measure condensate pipe (J) mark and cut square to length required. Fit sealing washer inside condensate pipe nut and connect to the flue manifold outlet (H). Connect 21.5mm polypropylene pipe (K) (not supplied) to the condensate pipe (J) and condensate trap (L) before terminating to waste. Secure the condensate trap (L) with clamp supplied. Ensure that the condensate pipe runs away from the boiler at a constant fall of 50mm (min.) for every metre. Carefully pour 500ml of water into the condensate collection (R) to fill condensate trap. Check the water is running away and the condensate pipework joints are water tight. Check the flue manifold seal is undamaged and seated correctly. Refit flue manifold access cover (Q) and secure with screws (P). IMPORTANT: The condensate trap must be correctly filled to prevent the possibility of potentially harmful flue products escaping via the condensate pipework. INSTALLATION H J K L M PRESSURE RELIEF CONNECTION: Connect the pressure relief pipe (M) to a copper discharge pipe (15mmØ min.) and terminate externally to the appliance casing. Blank all unused casing holes with the bungs or cover plates and seals supplied. The drain/fire valve capillary hole covers should be rotated so that the unused capillary slot is covered by the cover plate and seal. Refit rear panel. Seal all joints where pipes pass through the casing, with suitable waterproof sealant. IMPORTANT: Insulate all external condensate pipe work or run in 32mm pipe work to prevent freezing. 24 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) PIPEWORK CONNECTIONS OIL BURNER & PUMP 12/18 & 18/25 kW 1 Electrode gap 2.5 - 3.0mm CAUTION: ISOLATE THE OIL & WATER MAINS SUPPLY BEFORE STARTING ANY W OR K AN D OB S E RVE ALL R E LE VANT SAFETY PRECAUTIONS. OIL BURNER: B 1 Check the nozzle (A) and electrode (B) settings are correct for the relevant burner as shown opposite. A 5mm Ensure nozzle (A) is aligned centrally within the combustion head (C). 5mm Inspect for any visible defects. C 7.5mm 1 25/32 kW A INSTALLATION B IMPORTANT: Whenever replacing the combustion head, ensure that the photocell is lined up with the sight hole. 5mm 5mm OIL PUMP: C Connecting the oil pump for a single pipe system: The pump is factory set for single pipe operation with the flexible oil hose fitted. Check connections before use. Electrode gap 4mm Converting the oil pump for a double pipe system: a) DANFOSS BFP 11 L3 OIL PUMP 1 Check the inlet hose connection. b) SUNTEC AS47C OIL PUMP a) DANFOSS BFP 11 L3: A Remove pump front cover (A) ensuring a suitable receptacle is used to catch any oil residue. Remove changeover screw (B). B Remove horseshoe washer (C). Refit changeover screw (B). Refit front cover (A). 2 1 C B 1 2 Remove oil pump return plug (2). b) SUNTEC AS47C: Remove return port plug (2) and insert grub screw (B). c) RIELLO RDB OIL PUMP c) RIELLO RDB: Unscrew return plug (2). Screw in by-pass screw (3). 2 Connect the flexible oil return hose (not supplied) between the oil pump and the return line connection, and tighten to secure. 1 3 2 25 OIL BURNER & PUMP INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) REFITTING COMPONENTS 1 Align burner combustion head (A) into boiler housing tube with gasket (B) correctly fitted. Push firmly down to compress the gasket (B). Tighten burner retainers (C) sufficiently to ensure a good seal. IMPORTANT: Ensure the gasket is a good seal between the burner combustion head and the boiler housing to prevent flue gases escaping from the combustion chamber into the cabinet. B A C Attach the flexible air duct and tighten clamp(D) to secure to the burner air intake. 2 Plug burner lead (E) into control box (F). INSTALLATION D F E 26 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) REFITTING COMPONENTS ELECTRICS B 1 DANGER - 230V: ISOLATE THE MAINS ELECTRICITY SUPPLY BEFORE STARTING ANY WORK AND OBSERVE ALL RELEVANT SAFETY PRECAUTIONS. C B IMPORTANT: THIS APPLIANCE PROVIDES A PERMENANT EXTERNAL ELECTRICAL SUPPLY FOR SERVICING AND MUST THEREFORE BE FED VIA A CIRCUIT BREAKER INCORPORATING EARTH LEAKAGE PROTECTION. 230V MAINS SUPPLY IMPORTANT: OBSERVE ELECTRONIC STATIC DISCHARGE PRECAUTIONS. DO NOT TOUCH THE PCB CIRCUITS. A D 2/3 F WARNING: EXTERNAL EQUIPMENT OPERATED AT 230 VOLTS SHOULD NOT BE SERVICED OR REPAIRED UNDER ADVERSE WEATHER CONDITIONS. 4 G E INSTALLATION G Accelerator resistor (if fitted) Access to 230V connections: 1Release screws (B) and remove cover panel (C) from control box (A). 2Release screws (D) from cable clamp (E). Pull inner clamp part (F) outwards. Feed sufficient power cable (G) through the cable clamp (E) and secure grip with screw (D). Separate wires from cable end and strip to 6mm. P ROOMSTAT M 6 CH channel clock HW channel Live Any external device connected to the boiler must take its power supply from the boiler supply only and must NOT have a separate supply. 7 k 7 M X2 Ns Fs FR N L LR Ls FR DHW CH CONTROL BOARD Fuse N Supply FROST STAT(2) FROST STAT(1) CH Demand Switched Live 5 L Supply HW Demand Neutral (if required) PROGRAMMER (EXTERNAL) 230V connections (terminal block X1): 3Connect LIVE wire (Brown) to terminal L. Connect NEUTRAL wire (Blue) to terminal N. Connect EARTH wire (Green/Yellow) to the connector . Route the power cable down the side panel and through the service duct to the internal property connection point avoiding any potentially hot surfaces. External 230V programmer (terminal block X4): 4 Remove 4 pin plug (M) from X4. Remove test links (P) from plug block (M). Connect wires to plug block (M) as shown. Fit plug into terminal block X4. Connect earth to terminal block X1connector . 230V room thermostat (terminal block X2): 6 Remove link (K). Connect LIVE supply to terminal LS. Connect SWITCHED LIVE supply to terminal LR. NOTE: This is sometimes refered to as ‘call for heat’ or ‘heating load’. Connect NEUTRAL to terminal Ns. NOTE: Some devices do not require this. Refit electric control panel cover: Refit panel (C) and secure with screws (B). X4 NOTE: Both frost thermostats are fitted as standard to the external appliance to provide frost protection. 27 ELECTRICS INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) ELECTRICS Electrical components: 1 Printed circuit board 2 Thermostat - boiler high limit 3 Thermostat - DHW control 4 Thermostat - CH control 5 Indicator lamp - boiler mode 6 Indicator lamp - lock-out 7 Manual reset - overheat thermostat 8 Manual reset - flue overheat thermostat 9 Manual reset - burner lock-out 10 External programmer (not supplied) 11 Burner socket 12 Burner plug 13 Burner control box (12/18 & 18/25 shown) 14 Flow switch 15 Circulating pump 16 Diverter valve 17 Frost stat 18 Frost stat 1 NL Mains connection 18 Mode switch 17 Service connection 1 gy gy bl br X3 y bl gy bl br br X1 gy or bl br g X7 X6 y X2 X11 gy pk pk g bk X9 bl br w g g X8 w X12 pk or y w X10 X4 X13 Wire colour code: br - Brown bl - Blue gy - Green/Yellow r - Red w - White y - Yellow g - Grey bk - Black or - Orange pk - Pink INSTALLATION 230V 2 3 2 4 r or g w w 3 4 3 3 or r 7 r pk 14 y 6 y r w bk r 8 11 bl y 5 2 2 r pk pk 4 12 w g gy w 1 2 3 4 5 6 9 10 1 2 3 4 5 6 bk r g gy w br gy bl 15 br g bk r gy w gy or bl br g 1 2 3 4 5 6 7 8 9 16 13 A 28 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) ELECTRICS PRE-COMMISSIONING CHECKS APPLIANCE 1 CAUTION: ISOLATE THE MAINS SUPPLIES BEFORE STARTING ANY WORK AND OBSERVE ALL RELEVANT SAFETY PRECAUTIONS. 3 1 Check that the service and water pipes are connected correctly. 2 Check that all unused sockets are capped. 2 Check that the oil supply is kerosene and that the pipework is connected correctly to the oil pump via the supplied flexible oil hose. Turn on the main oil supply valve at the tank, check the oil supply pipework and connections. Rectify any leaks. 3 Check the flue is correctly fitted and the connections are secure. 4 Check the condensate pipework is correctly fitted and connected. 5 Check the condensate trap is filled with water. 5 Check the CH circulating pump is set to 3. 4 NOTE: The CH circulating pump is preset to number 3 and should not be altered. The diagrams opposite show the pump outputs. COMMISSIONING NOTE: The cabinet is not load bearing, it only provides weather protection for the boiler inside. 12/18 & 18/25 0.6 0.5 0.4 Bar 0.3 0.2 0.1 0 0 200 400 600 800 IMPORTANT: If the boiler is not to be commissioned immediately then: 1000 1200 1400 1600 Litres per hour After successfully completing all of the checks and any rectification work, close the water valves, shut off the oil supply and electrically isolate the boiler. 25/32 0.7 Complete the installation part of the Guarantee Registration Card, and complete a CD10 or its equivalent, to inform the LABC of the installation. 0.6 0.5 Bar 0.4 0.3 0.2 0.1 0 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Litres per hour 29 PRE-COMMISSIONING CHECKS - APPLIANCE INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) FILLING THE SYSTEM 1 B 1 Pull lever (C) up and push to the left to move the diverter valve to the mid-position between ports A and B. A C Push and hold lever (C) down to lock. 2 Loosen the automatic air vent cover. 4 Sealed systems only; check and if required, adjust the expansion vessel pressure using the Schraeder type valve (D). 2 The charge pressure of the built-in 12 Litre expansion vessel is 0.5 bar as dispatched, which is equivalent to a static head of 5 metres (16.7 ft). 3 Total system Initial system Initial charge volume (litres) pressure (bar) pressure (bar) 0.5 0.5 180 1.0 0.5 107 1.0 1.0 138 D If an extra expansion vessel is fitted to the central heating return, adjust this to the same pressure as the appliance internal expansion vessel, refer to separate instructions supplied with the extra expansion vessel. 4 Open all system and radiator valves (E). Turn on the water main stop cock. 4 E Open vented systems only; turn on the water to the system feed and expansion cistern and allow the system to fill. Sealed systems only; fill the system to between 1 and 2 bar pressure via a WRAS approved filling link. Monitor the pressure gauge during venting and repressurise if required. E F Check air is being discharged from the automatic air vent. Vent all radiators, retighten when completed, check the system and correct any leaks. COMMISSIONING 1 - 2 bar Bleed air from both of the secondary heat exchanger air vents (F). Bleed air from the pipework using the pump bleed screw. 5 Sealed systems only; connect a suitable hose to the Heatslave tank drain. Open the drain valve to reduce the system to the correct pressure, then close the drain valve. Ensure safe disposal of the discharge. Rotate the adjustable pointer on the pressure gauge to record the set system pressure. 5 6 Check system and rectify any leaks. Push lever (C) to the left and pull upwards to allow the lever to return to position A. Leave the lever (C) unlocked at position A. 6 B C A 30 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) FILLING THE SYSTEM STARTING THE APPLIANCE IMPORTANT: Never run the appliance when the appliance/system is unpressurised (sealed systems) or empty. 1 1Check the oil supply is correctly fitted and in good working order before turning on the oil supply valves to the boiler. on max service max Turn on the main oil supply valve at the tank and draw off at least 21/2 litres of oil until a steady flow of clear uncontaminated oil can be seen as follows: lockout flue reset boiler reset GREENSTAR HEATSLAVE EXTERNAL DANFOSS SUNTEC RIELLO BFP 11 L3 OIL PUMP AS47C OIL PUMP RDB OIL PUMP A D A C D B B B C C D A B - Pressure adjustment C - Vacuum gauge port Single pipe gravity feed systems: Disconnect the flexible oil hose and open the isolating valve to discharge the oil into a suitable container. When completed, close the isolating valve, reconnect the flexible oil hose. D - Retaining screws - cover COMMISSIONING • The use of an oil suction pump will prime and flush through any oil supply set up simply and easily, alternatively the following procedures can be used. If a top entry tank has been used the pipework will need to be primed before the oil will discharge under gravity. A - Bleed & pressure gauge port E - Lockout indicator BURNER LOCKOUT • The oil supply to the boiler should be primed before the burner is operated to avoid unnecessary pump wear. Double pipe sub-gravity feed systems and single pipe suction lift with de-aerator: To prime a de-aerator, disconnect the flexible oil inlet hose (F) from the isolation valve and place in a container of kerosene (G). Connect a spare flexible oil hose (H), to discharge into container (G). Open the isolating valve, turn on the power to the boiler and set the programmer to ON. Prime the de-aerator until there is a steady flow of oil into container (G). Turn off the boiler then reconnect the flexible oil inlet hose (F). BURNER LOCKOUT RESET BUTTON (D) FOR 12/18 & 18/25 MODELS (Under control box) BURNER LOCKOUT RESET BUTTON (D) FOR Turn on the boiler, the oil level in the de-aerator will drop as the oil is used until the oil is drawn from the tank. If the de-aerator empties and the burner locks out before the oil is drawn from the tank, prime the de-aerator again. 25/32 MODEL (On top of burner control box) Open the isolating valve and the oil pump bleed valve (A) to discharge into a suitable container once the boiler is started up. Switch on the electricity supply to the boiler. Set the programmer to ON for CH and DHW. Turn on the boiler CH control thermostat. Return Allow the burner to run through to lockout indicated by the illumination of the lockout indicator (E). Flow Wait 2 minutes then press the lockout reset button (D). H TANK F G Repeat the procedure at least 3 times or until a steady stream of oil, without air, runs from the bleed port, then relock the bleed port (A). Switch off the boiler. Remove the oil pump filter, clean with kerosene and refit. The internal filter is accessed by removing the oil pump cover on the Danfoss BFP 11 L3, Suntec AS47C and Riello RDB. Safely dispose of the container/discharge. 31 STARTING THE APPLIANCE INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) 2 STARTING THE APPLIANCE E D 25/32 (on top of burner control box) D 12/18 & 18/25 (under control box) 4 3 K DANFOSS SUNTEC RIELLO BFP 11 L3 OIL PUMP AS47C OIL PUMP RDB OIL PUMP A If after-spurting occurs: Release the burner retainers. Remove the burner, combustion head (F). and electrodes, hold the burner vertical to unscrew the nozzle and fill the nozzle holder with oil. Refit nozzle, electrodes, combustion head (F) and the burner. Restart and run for 3 minute intervals until after-spurting stops. 4Start and run for 20 minutes. Remove sampling point plug (K) to check the smoke reading is between 0-1. If the smoke level is above 1, check the combustion settings are correct and the oil nozzle is in good condition. C C B B B C If the burner fails to establish a normal firing pattern or flame failure occurs the flame monitoring photocell mounted in the burner body will alert the burner control box to shut the burner down and provide a safe lockout state indicated by the illumination of the lockout indicator (E). Wait 2 minutes then press the lockout reset button (D) to initiate another start sequence. Repeat procedure until a flame is established. 3Start and run for 3 minutes then switch off. Check for after-spurting from the nozzle, indicated by oil saturation on the combustion head (F). G A Boiler lockout indicator on: A A - Bleed & pressure gauge port B - Pressure adjustment C - Vacuum gauge port 5 COMMISSIONING F 2Remove plastic cover from the burner casing (there is no plastic cover on the Riello burner). Fit a suitable pressure gauge to port (A) on the oil pump. Adjust the air shutter (L) and pump pressure (B) as shown in the table opposite. The burner should ignite following a pre-ignition period of approx. 15 seconds. Note; smoke readings may be inaccurate until the smoke from burning organic binder in the access door insulation has ceased. L Check the CO2 levels and adjust the air shutter (L) setting according to the table opposite. Check the flue gas temperature is close to the values shown in the table. L NOMINAL BOILER RATING AT NORMAL OPERATING TEMPERATURE USING 28sec KEROSENE: OIL PUMP NOZZLE FUEL PRESSURE FLOW RATE (p.s.i.) Kg/h l/h APPROX. FLUE GAS APPROX. %CO2 TEMP °C APPLIANCE AIR INPUT SETTING kW OUTPUT Btu/hr kW Btu/hr 12/18 - Bentone Sterling 40 Burner: 0.35 80°SR 115 1.04 1.32 66 11.5 2.5 12.4 42300 12 40900 0.45 80°S 115 1.29 1.63 70 12.0 4.5 15.5 52900 15 51200 0.50 80°ES 140 1.55 1.96 73 12.5 5.25 18.6 63500 18 61400 18 61400 18/25 - Bentone Sterling 50 Burner: 0.50 80°EH 130 1.56 1.98 72 11.5 4.25 18.6 63500 0.55 80°EH 145 1.86 2.36 79 12.0 6.0 22.2 75750 21.5 73400 0.65 80°EH 150 2.17 2.75 82 12.5 8.0 25.8 88000 25 85300 85300 If the flue gas temperature is too high and the baffles are correctly fitted, then reduce the oil pump pressure (B) 5-10p.s.i. to compensate for nozzle variations. Turn off the electrical supply. Isolate the oil supply to the burner. Remove the oil pressure gauge. Refit the blanking plug (A). Check and rectify any oil leaks. 5Switch on the oil supply. Switch on the electrical supply. Restart the boiler and run for 5 minutes. Recheck the CO2 levels and if required, adjust the air shutter setting (L) to obtain the correct CO2 level. 25/32 - Riello RDB Burner: 0.75 60°ES 105 2.15 2.72 78 11.5 3.0 25.5 87000 25 0.75 60°ES 140 2.45 3.1 80 12.0 4.0 29.1 99300 28.5 0.85 60°ES 150 2.75 3.48 83 12.5 5.0 32.7 111600 32 97200 109200 32 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) STARTING THE APPLIANCE STARTING THE APPLIANCE Domestic hot water: 1Set the CH/DHW programmer to OFF. Fully open a hot water tap. 1 The burner should be OFF and the circulating pump ON. 2 on max service max lockout flue reset boiler reset GREENSTAR HEATSLAVE EXTERNAL C 3 Fully open a hot water tap. The burner should be ON with the circulating pump. Check the water flow rate using a suitable measuring container; 12/18KW 15 litres/min 18/25kW 18 litres/min* 25/32kW 22 litres/min* * Manually regulate using the water main inlet isolating valve on the boiler. 4 Fully close the hot water tap. Check the burner and circulating pump** switch off. 3 on COMMISSIONING 2Close the hot water tap. Set the DHW thermostat control (C) to minimum as shown. Set the programmer to DHW ON. The burner should be ON with the circulating pump to heat the water in the Heatslave external tank. When minimum set temperature is reached the burner and circulating pump will switch off. max service max **The high limit thermostat may activate pump overrun until the correct temperature is restored. lockout flue reset boiler reset GREENSTAR HEATSLAVE EXTERNAL 4 on max service max lockout flue reset boiler reset GREENSTAR HEATSLAVE EXTERNAL 33 STARTING THE APPLIANCE INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) STARTING THE APPLIANCE 1 on max service max lockout flue reset C boiler reset GREENSTAR HEATSLAVE EXTERNAL Central heating: 1 Open all radiator valves. Set room thermostat to maximum. Set programmer to ON for CH. Turn the DHW thermostat control (C) fully anti-clockwise. Turn the CH thermostat control (D) to max. The burner should be ON with the circulating pump. The diverter valve (E) should open to port B for CH. Ensure all radiators are heating up evenly and balance the system to the temperature difference required across the heating flow and return relevant to the heating load. D E 2 2Set the room thermostat to minimum. The burner and circulating pump should be off. The diverter valve (E) should return to port A for DHW (default). on service max lockout flue reset boiler reset GREENSTAR HEATSLAVE EXTERNAL The burner should be ON with the circulating pump. The diverter valve (E) should open to port B for CH. E 4Set the DHW thermostat control (C) to max. The diverter valve (E) should move to port A and divert the flow to the Heatslave tank. 3 on max service max COMMISSIONING max Domestic hot water & central heating: 3Set the room thermostat to maximum. Set the programmer to ON for DHW & CH. Turn the DHW thermostat control (C) fully anti-clockwise. Set the CH thermostat control (D) to max. lockout flue reset boiler reset GREENSTAR HEATSLAVE EXTERNAL D C E 4 on max service max lockout flue reset C boiler reset GREENSTAR HEATSLAVE EXTERNAL D E 34 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) STARTING THE APPLIANCE WATER TREATMENT IMPORTANT: Debris from the system can damage the boiler and reduce efficiency. Failure to comply with the guidelines for the use of water treatment with the appliance will invalidate the appliance warranty. 1 FLUSHING (Central Heating): 1Switch off the boiler. Open vented systems only: turn off the water to the system header tank. Open all radiator valves/drain cocks (C) and drain the system while the appliance is hot. Close drain cocks (C). C C 2 2Add a suitable flushing agent (F) and refill the system at the correct strength for the system condition in accordance with the manufacturer's instructions. Vent the boiler (there are two vent points (A) at the top of the secondary heat exchanger. Only one may be in use, the other may be obscured by side fluing. Always vent (A) and the vent screw (B) on the pump and all radiators. Run the boiler/system at normal operating temperature for the time stated by the flushing agent manufacturer. A 3Drain and thoroughly flush the system and boiler to remove the flushing agent and debris (C). 3 B INHIBITOR (Central Heating): 4Check drain cocks (C) and manual air vents are closed and all radiator valves are open. COMMISSIONING C 5Add a suitable inhibitor (I), (or combined inhibitor/anti-freeze if the system is exposed to freezing conditions) to the heating system in accordance with the manufacturers instructions. C The inhibitor or combined inhibitor/anti-freeze must not cause damage to the materials within the boiler (mild steel, stainless steel, copper and brass) and any other materials/components within the system. 4 Open vented systems only: turn on the water to the system header tank and allow the system to fill. Sealed systems only: fill the system to between 1 and 2 bar via a WRAS approved filling loop. Check the system pressure during venting and repressurise if necessary. C 5 6Vent the boiler (there are two vent points (A) at the top of the secondary heat exchanger. Only one may be in use, the other maybe obscured by side fluing. Always vent (A) and the vent screw (B) on the pump and all radiators; retighten vents when complete. 1 - 2 bar A 6 7Record the date when the inhibitor was added to the system on the guarantee card. NOTE: The concentration level of inhibitor in the system should be checked every 12 months or sooner if system content is lost. B The addition of sealing agents to the system water is not advised as this can cause problems with deposits left in the heat exchanger and invalidate the appliance and heat exchanger warranty . 35 WATER TREATMENT INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) FINISHING COMMISSIONING APPLIANCE 1 Refit the top panel and press down to compress the seal when fitting the securing screws (A). 2 Push the front panel up behind the top panel and push in at the base to secure the screws (B) with the tool provided. A A Always apply pressure at the edges of the panels when securing to avoid accidental damage. 1 2 COMMISSIONING C B B K Handover: Complete the guarantee registration card, combustion record (page 49) and a CD11 or an equivalent commissioning form. Set up the controls and show the user how to operate all the controls shown in the User Guide, and all system controls. Where applicable, instruct the customer how to repressurise the system. If the appliance is unused and exposed to freezing conditions, shut off all the mains supplies and drain the system and boiler to prevent damage to the system and boiler. NOTE: Release drain point (K) to drain the secondary heat exchanger. 36 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) FINISHING COMMISSIONING APPLIANCE 31 INSPECTION AND SERVICE CAUTION: ISOLATE THE WATER, ELECTRICITY AND OIL MAINS SUPPLIES BEFORE STARTING ANY WORK AND OBSERVE ALL RELEVANT SAFETY PRECAUTIONS. on DO NOT USE PRESSURE WASHERS OR STEAM CLEANERS ON THIS APPLIANCE OR ITS CABINET. A service WARNING: EXTERNAL EQUIPMENT OPERATED AT 230 VOLTS SHOULD NOT BE SERVICED OR REPAIRED UNDER ADVERSE WEATHER CONDITIONS Routine servicing: 1 To maintain efficient boiler operation, the following should be carried out at least once a year: C Carry out a pre-service check and note any operational faults: 2 Pre-Service Check: B G 1Unndo the screws at the base of the front panel using the tool provided and pull the panel down and out to remove. Store safely away from the working area. Operate the appliance and system and note any faults which may need to be corrected during the service. Switch into service mode at switch (A). 2Depress locking ears and unplug burner lead (B) from control box (C). • An adapter lead is available to allow mains voltage service aids to be operated from the service connection (G). (Service lead Part No. 8 716 113 483 0). 3Loosen clip (D) to detach air duct. SERVICING & SPARES 4Unscrew burner retainers (E) to release the burner combustion head (F). Lift burner away, taking care not to over strain the flexible oil hose/s or connections. 3 D 4 F E See the following instructions for detail of some of the service requirements listed below: Check and clean the burner. Replace burner nozzle and flexible oil hose/s. Check and clean the baffle retainers. Check and clean the baffles. Check and clean the heat exchangers surfaces. Check the combustion chamber access door insulation board. Check that the flue system is unobstructed and clean as necessary. Clean or replace all oil filters. Check that the condensate system is not obstructed, clean and refill the condensate trap as necessary. Sealed systems only: The PRV is a safety device and must be checked for correct operation. The expansion vessel pressure must be checked and adjusted as required. 37 INSPECTION AND SERVICE INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) INSPECTION AND SERVICE 1 Clean the Burner: 12/18 & 18/25 P Remove the air intake cover (H) and clear any debris from the air intake and air damper. Disassemble the burner to allow access to the fan impeller. Check the condition of the gaskets between these parts and replace if necessary. Note the position of the air damper adjustment and check the air damper moves freely. Clean both sides of the fan impeller and remove any debris from the burner housing. Check that the impeller rotates freely. Reassemble the components. Remove the combustion head (K) and thoroughly clean any deposits. Remove the nozzle (E). H D N Electrode gap 2.5 - 3.0mm M O L F E 5mm 5mm 2 12/18 & 18/25 Inspection of Mechanical Shut-off Valve: K Fasten an M5 screw, with a minimum length of 30mm, into the threaded hole (L) and pull the screw to withdraw the check valve (M). Check that the nozzle holder (N) is clear of any debris and clean if necessary. Check that the three holes in the check valve (M) are clear of any debris. Check the condition of the 'O' ring (O). Discard the check valve if the holes cannot be cleared, if the unit is defective or if the 'O' ring is damaged and replace with a new one. Refit the check valve. 7.5mm 25/32 P H D 25/32 Check the nozzle holder is clear of any debris and clean if neccessary. F E 5mm 5mm 12/18, 18/25 & 25/32 Fit a new oil atomising nozzle (E). Check the electrodes (F) and reset if necessary as shown opposite. Refit the combustion head. Check that the nozzle (E) lies centrally in the combustion head and the head settings are as shown. Ensure that the photocell is lined up with the sight hole. Withdraw the photocell (P) from its housing and wipe clean. Remove the oil pump internal filter, clean in kerosene and reassemble. K Electrode gap 4mm DANFOSS SUNTEC RIELLO BFP 11 L3 OIL PUMP AS47C OIL PUMP RDB OIL PUMP A A B A - Retaining screws - cover The internal filter is accessed by removing screws (A) and the oil pump cover (B) on the Danfoss BFP 11 L3, Suntec AS47C and Riello RDB. A B SERVICING & SPARES DO NOT dismantle the nozzle and DO NOT clean the nozzle tip. B Replace the standard flexible oil hose/s at every annual service to prevent the possibility of leakage due to ageing. Reassemble the burner components. Check the sponge O-ring seal located around the combustion head and replace if necessary. This seal must be in good condition since failure will cause flue gases to escape into the cabinet. B - Cover - oil pump 38 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) INSPECTION AND SERVICE INSPECTION AND SERVICE External oil filter: Remove the paper element from the external oil filter and replace it. If the filter contains a washable element, thoroughly clean in kerosene and reassemble into the filter. Clean the boiler: Manifold access: E F J H K G or J H G A SERVICING & SPARES B Plan sectional view Plan sectional view 25/32kW 12/18kW & 18/25kW C C Remove top cover by releasing the screws at each corner and lift free. Release screws (E) to remove the flue manifold access cover (F) and clear any debris. Check the condensate route (G) is clear and clean the condensate trap and pipework. Check the flue system and clean if necessary. Remove the baffle retainer (J) and baffles (H) from the secondary heat exchanger. Check and clean the secondary heat exchanger surfaces. NOTE: Do not use wire brushes and cleaning agents to clean the stainless steel secondary heat exchanger components. Pour 500ml of water into drain (G) to refill the condensate trap. Clean the secondary heat exchanger baffles (H) if necessary and refit correctly. Refit the baffle retainer (J). Check the seal on the manifold access cover (F) and replace if necessary. Refit the flue manifold access cover (F) and secure with screws (E). Combustion chamber: Release the M10 retaining nuts and washers (B) and remove combustion chamber access door (A). Check the fibreglass rope seal on the combustion chamber access door (A) and replace if necessary. Remove and check the baffle retainer (D). Remove the baffles (C), clean and check the condition of the baffles and the acoustic insulation. Replace any baffles or insulation pads considered to be badly corroded/degraded. Thoroughly clean all of the heat exchanger surfaces using a suitable brush and clear all loose debris from the combustion chamber. Check the condition of the combustion chamber access door insulation. If the insulation is damaged the door assembly must be replaced. Refit the items in reverse order ensure the baffles (C) and baffle retainers (D) are correctly fitted for the boiler output as shown in the plan view opposite. Refit combustion access door (A). Secure with nuts and washers (B) and tighten until the door is firmly secured, do not over tighten the nuts. Fire valve: D FRONT D Check that the oil supply pipe has a fire valve fitted at least 1m away from the appliance with the fire valve sensor located within the appliance case. A fire valve sensor clip (K) is provided for this purpose. FRONT 39 INSPECTION AND SERVICE INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) INSPECTION AND SERVICE B A C Re-commission the burner: 1Align burner combustion head (A) into the boiler housing tube with gasket (B) correctly fitted. Push firmly down to compress the gasket (B). Tighten burner retainers (C) sufficiently to ensure a good seal. D IMPORTANT: Ensure the gasket is a good seal between the burner combustion head and the boiler housing to prevent flue gases escaping. Refit flexible air duct and secure with clip (D). 2Plug burner lead (E) into control box (F). Connect an oil pressure gauge to the oil pump, run the burner and check the oil pressure is correct for the required boiler output. Check that the smoke reading is between 0 and 1, if the smoke reading is above 1 check the air setting. If the air setting is correct check that the burner has been reassembled correctly. Allow the boiler to warm up then check the combustion settings are correct as indicated in the table below, adjust the CO2 if necessary using the air shutter. When the combustion is correct turn off the boiler, remove the pressure gauge and refit the blanking plug and plastic cover. F E Refit panels: 3Refit the top panel and press down to compress the seal when fitting the securing screws. Push the front panel up behind the top panel and push in at the base to secure the screws with the tool provided. Make a note of the date of any water treatment. Set the controls back to the users requirements. Complete the service interval record at the back of this manual and a CD11 or an equivalent form. If the appliance is unused and exposed to freezing conditions; shut off all the mains supplies, isolate the boiler and drain the system and boiler, including the secondary heat exchanger. NOMINAL BOILER RATING AT NORMAL OPERATING TEMPERATURE USING 28sec KEROSENE: OIL PUMP NOZZLE FUEL PRESSURE FLOW RATE (p.s.i.) Kg/h l/h APPROX. FLUE GAS APPROX. %CO2 TEMP °C SERVICING & SPARES After service handover: APPLIANCE AIR INPUT SETTING kW OUTPUT Btu/hr kW Btu/hr 12/18 - Bentone Sterling 40 Burner: 0.35 80°SR 115 1.04 1.32 66 11.5 2.5 12.4 42300 12 40900 0.45 80°S 115 1.29 1.63 70 12.0 4.5 15.5 52900 15 51200 0.50 80°ES 140 1.55 1.96 73 12.5 5.25 18.6 63500 18 61400 18 61400 18/25 - Bentone Sterling 50 Burner: 0.50 80°EH 130 1.56 1.98 72 11.5 4.25 18.6 63500 0.55 80°EH 145 1.86 2.36 79 12.0 6.0 22.2 75750 21.5 73400 0.65 80°EH 150 2.17 2.75 82 12.5 8.0 25.8 88000 25 85300 85300 25/32 - Riello RDB Burner: 0.75 60°ES 105 2.15 2.72 78 11.5 3.0 25.5 87000 25 0.75 60°ES 140 2.45 3.1 80 12.0 4.0 29.1 99300 28.5 0.85 60°ES 150 2.75 3.48 83 12.5 5.0 32.7 111600 32 97200 109200 40 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) INSPECTION AND SERVICE SHORT PARTS LIST 12/18 1 2 1 Burner - Sterling 40 Part Number: 8 716 112 507 0 2 Combustion head - burner Part Number: 8 716 112 604 0 3 Control box Satronic DKO 970 Part Number: 8 716 142 396 0 4 Photocell Satronic MZ770s 3 4 5 6 Part Number: 8 716 156 692 0 5 Control box base Satronic S98 12 pole Part Number: 8 716 142 782 0 6 Ignition electrode Part Number: 8 716 156 683 0 7 Motor Part Number: 8 716 156 645 0 8 Oil pump - Danfoss BFP 11 L3 7 8 8a 9 Part Number: 8 716 142 736 0 8a Oil pump - Suntec AS47C Part Number: 8 716 157 014 0 9 Transformer (Excludes cable) Part Number: 8 716 156 696 0 10 Mechanical shut-off valve Part Number: 8 716 156 658 0 11 Flexible oil line kit Part Number: 8 716 106 346 0 12 Burner 'O' ring gasket Part Number: 8 716 109 158 0 13 Heating control thermostat 10 11 12 13 Part Number: 8 716 107 621 0 14 Auto reset High Limit thermostat Part Number: 8 716 107 640 0 15 Manual reset High Limit thermostat Part Number: 8 716 107 625 0 16 Manual reset flue thermostat Part Number: 8 716 107 624 0 17 DHW control thermostat Part Number: 8 716 107 637 0 15 16 17 SERVICING & SPARES 14 18 Cleaning brush Part Number: 8 716 109 428 0 19 Manifold access cover seal Part Number: 8 716 107 536 0 18 19 20 21 20 Secondary Heat Exchanger gasket Part Number: 8 716 112 954 0 21 Frost thermostat Part Number: 8 716 105 965 0 22 Service lead Part Number: 8 716 113 483 0 23 Oil nozzle 0.35 80° SR (12kW output) Part Number: 8 716 112 628 0 0.45 80° S (15kW output) Part Number: 8 716 106 197 0 22 23 0.50 80° ES (18kW output) Part Number: 8 716 156 669 0 41 SHORT PARTS LIST 12/18 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) SHORT PARTS LIST 18/25 1 2 1 Burner - Sterling 50 Part Number: 8 716 112 570 0 2 Combustion head - burner Part Number: 8 716 108 573 0 3 Control box Satronic DKO 970 Part Number: 8 716 142 396 0 4 Photocell Satronic MZ770s 3 4 5 6 Part Number: 8 716 156 692 0 5 Control box base Satronic S98 12 pole Part Number: 8 716 142 782 0 6 Ignition electrode Part Number: 8 716 156 683 0 7 Motor Part Number: 8 716 156 645 0 8 Oil pump - Danfoss BFP 11 L3 7 8 8a 9 Part Number: 8 716 142 736 0 8a Oil pump - Suntec AS47C Part Number: 8 716 157 014 0 9 Transformer (Excludes cable) Part Number: 8 716 156 696 0 10 Mechanical shut-off valve Part Number: 8 716 156 658 0 11 Flexible oil line kit Part Number: 8 716 106 346 0 12 Burner 'O' ring gasket Part Number: 8 716 109 158 0 13 Heating control thermostat 10 11 12 13 Part Number: 8 716 107 621 0 14 Auto reset High Limit thermostat Part Number: 8 716 107 640 0 15 Manual reset High Limit thermostat Part Number: 8 716 107 625 0 16 Manual reset flue thermostat Part Number: 8 716 107 624 0 14 15 16 17 18 Cleaning brush Part Number: 8 716 109 428 0 19 Manifold access cover seal Part Number: 8 716 107 536 0 18 19 20 21 20 Secondary Heat Exchanger gasket Part Number: 8 716 112 954 0 21 Frost thermostat Part Number: 8 716 105 965 0 22 Service lead Part Number: 8 716 113 483 0 SERVICING & SPARES 17 DHW control thermostat Part Number: 8 716 107 637 0 21 Oil nozzle 0.50 80° EH (18kW output) Part Number: 8 716 156 672 0 0.55 80° EH (21.5kW output) Part Number: 8 716 156 671 0 22 23 0.65 80° EH (25kW output) Part Number: 8 716 110 362 0 42 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) SHORT PARTS LIST 18/25 SHORT PARTS LIST 25/32 3 2 1 4 1 Burner - Riello RDB 2.2 25/32 HE Part Number: 8 716 112 512 0 2 Combustion head - burner Part Number: 8 716 112 521 0 3 Control box 535 SE/LD Part Number: 8 716 109 203 0 4 Photocell 5 6 7 7a Part Number: 8 716 109 193 0 5 Ignition electrode Part Number: 8 716 109 183 0 6 Motor Part Number: 8 716 109 186 0 7 Oil pump - Riello RDB Part Number: 8 716 109 182 0 8 Flexible oil line kit 8 9 10 11 Part Number: 8 716 106 346 0 9 Burner 'O' ring gasket Part Number: 8 716 109 158 0 10 Heating control thermostat Part Number: 8 716 107 621 0 11 Auto reset High Limit thermostat Part Number: 8 716 107 640 0 12 Manual reset High Limit thermostat Part Number: 8 716 107 625 0 13 Manual reset flue thermostat Part Number: 8 716 107 624 0 14 DHW control thermostat 12 13 14 15 Part Number: 8 716 107 637 0 15 Cleaning brush Part Number: 8 716 109 428 0 16 Manifold access cover seal Part Number: 8 716 107 536 0 17 Secondary Heat Exchanger gasket Part Number: 8 716 112 954 0 SERVICING & SPARES 18 Frost thermostat Part Number: 8 716 105 965 0 16 17 18 19 19 Service lead Part Number: 8 716 113 483 0 20 Oil nozzle 0.75 60° ES (25 & 28.5kW output) Part Number: 8 716 106 156 0 0.85 60° ES (32kW output) Part Number: 8 716 110 083 0 20 43 SHORT PARTS LIST 25/32 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) PROBLEM CAUSE REMEDY Combustion settings incorrect Set up as in installation instructions Faulty nozzle Replace nozzle FAULT FINDING LOCKOUT: Pulsation on start Intermittent lockout Bad electrical connection Check control box/electrical connections Intermittent flame detection fault See flame detection fault Faulty motor or electrical supply to motor Check for 230v at motor plug during startup period Control box fault Replace control box Flame detection Photocell filmed over (dirty) Wipe clean fault Photocell faulty Replace Control box faulty Replace Burner motor fails to operate Incorrect CO2 No oil from nozzle Air adjustment fault Set up as in installation instructions Oil pressure incorrect Set up as in installation instructions No oil at pump Check and refill oil tank/bleed oil line BOILER LOCKOUT : Indicated by the illumination of the 'Lockout' indicator on the fascia. To reset, wait 2 minutes then press the lockout reset button. Also refer to fault finding logic on pages 46 and 47. Check and clean filters & valves from oil tank to boiler Air in pump Bleed pump Nozzle blocked Replace nozzle Faulty pump or drive Replace Faulty mechanical shut off valve Clean or replace Ignition failure Electrode settings incorrect Set up as in installation instructions Faulty ignition transformer Replace Open circuit ignition Check and replace electrodes or high tension leads if necessary Faulty control box or electrical connections not properly made Correct control box electrical connections or replace control box BURNER FAILS No power to boiler Check electrical / control circuit TO START Faulty boiler thermostat Check by temporarily linking out high limit and control thermostats Programmer open circuit Check by temporarily linking 8 & 9 on the connector Faulty control box Replace HIGH SMOKE Air intake/flue blocked Check & clear air intake/flue NUMBER Incorrect combustion settings Set up as in installation instructions Oil pressure incorrect Adjust to correct pressure Incorrect components used on combustion head Check with installation instructions Faulty nozzle Replace nozzle FAULT FINDING & DIAGRAMS (12/18 & 18/25 only) UNDER NO CIRCUMSTANCES MUST AN APPLIANCE BE LEFT TO OPERATE WITH ANY CONTOL LINKED OUT OR OVERRIDDEN. 44 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 106 252b (07/06 FAULT FINDING PROBLEM CAUSE REMEDY Pump noise from air in pump or worn pump Bleed air from pump or replace pump Worn motor bearings Replace motor Fan out of balance Replace fan FAULT FINDING FAULTY BOILER OPERATION: Noisy operation Boiling Short Cycling Replace if necessary Short circuit boiler thermostat Take out of circuit to check Thermostat bulb not fully home in pocket Ensure bulb is pushed fully home No primary water circulation Check system / circulating pump Burner rating incorrect Correct burner rating Boiler thermostat differential incorrect Replace boiler thermostat External controls not operating correctly Check and correct external controls Blocked flue, fumes on startup Check seals/gaskets Oil soaked boiler, faulty burner operation, numerous lockouts Rectify burner operation and lockouts Odour in cabinet, oil leaks from pipework, flexible hoses connections Rectify oil leaks, replace components if necessary FAULT FINDING & DIAGRAMS OIL SMELLS: Faulty boiler thermostat 45 FAULT FINDING INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) Yes Motor 40Ω No Check boiler controls & supply INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 106 252b (07/06 No No Yes No No Replace motor Check connections/ replace leads Replace motor/ pump Replace control box Yes Lockout within 1 second? Replace pump No Replace oil pump Yes Oil to pump? No Drive coupling broken? No Pump produces pressure? Yes Replace transformer Yes Electrodes & leads OK? Yes 230V at transformer? No Spark produced? Replace lead Yes Photo cell lead OK? No Yes Replace control box Yes Transformer lead OK? Lockout after purge before oil solenoid opens? Yes Disconnect photo cell, reset lockout, burner lights then locks out? No No No Yes FAULT FINDING FAULT FINDING & DIAGRAMS Note: This chart assumes all wiring within the control box base is correct, if in doubt check the wiring against the diagram on the base of the control box before replacing any components. All resistance measurements are actual measured values and some variation is to be expected, therefore measured values should be similar to but not necessarily identical to the given values. The operation of the photo cell can be tested by measuring the resistance across the photo cell, it should be a high resistance (greater than 10MΩ or open circuit) in the dark and low resistance (15kΩ or less) in light. Burners on balanced flue systems can recirculate flue products resulting in the burner cycling, if this happens check the flue system integrity and the terminal position. Replace motor capacitor Yes across L & N? 230V at motor? L & N to control box? Motor or pump seized? Burner lights immediately motor runs? No Yes Yes Yes 230V at solenoid coil in purge? Yes Replace control box No Control box locks out? No Burner motor runs? Boiler not operating with a heating / hot water demand Replace photo cell No Photo cell functional? No If BF remove burner snorkle tube & retest. Lights OK? Yes Flame off and re-lights? Yes Combustion head set correctly? Yes Combustion air setting correct? Yes Nozzle atomising fuel? Replace photo cell No Stray light on photo cell? Yes Yes No No No No Replace control box Reseal BF on reposition Boiler or flue blocked Reset combustion head Reset air setting 230V at solenoid coil? No Coil lead OK? No Replace coil lead Replace nozzle Yes Oil check valve OK? (if fitted) Yes Pipe to nozzle holder OK? Yes Solenoid operating? Yes 2.2kΩ across solenoid coil? Replace control box No No No Replace oil check valve (if fitted) Replace pump Replace solenoid coil Measure all 230V tests between Neutral (N) and the pin, wire or terminal specified. Yes Yes These fault finding charts are provided to assist competent and suitably qualified engineers to locate and rectify faults. Whilst every effort has been taken to ensure the information given is correct and complete we cannot guarantee that every eventuality has been covered. Worcester, Bosch Group cannot be held responsible for costs incurred by persons not deemed to be competent. FAULT FINDING LOGIC FOR SATRONIC CONTROL BOX 46 FAULT FINDING 47 INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07) Replace photo cell Replace control box Yes No No Yes Yes Unblock or replace pipe No Replace control box Replace solenoid coil Replace motor Replace oil pump Yes Oil to pump? No Drive coupling broken? No Purge pressure 1-2 bar? No Pump produces pressure? Yes Yes Replace solenoid coil No (100Ω)? Solenoid coil Yes functional No Solenoid operating? Increase the pump pressure, pressure OK? Replace photo cell Replace control box Photo cell functional? No Remove burner snorkle tube & retest. Lights OK? Yes Flame off & re-lights? Yes Combustion head set correctly? No Yes No Replace pump stem valve, pressure OK? Yes Coil lead OK? Combustion air setting correct? Nozzle atomising fuel? Yes No Reset air setting No All resistance measurements are actual measured values and some variation is to be expected, therefore measured values should be similar to but not necessarily identical to the given values. The operation of the photo cell can be tested by measuring the resistance across the photo cell, it should be a high resistance (greater than 10MΩ or open circuit) in the dark and low resistance (3kΩ or less) in light. Burners on balanced flue systems can recirculate flue products resulting in the burner cycling, if this happens check the flue system integrity and the terminal position. No Yes Replace motor Photo cell functional? No Motor 40Ω between blue & black wires ? (100Ω)? Yes Replace motor/pump No Yes Solenoid coil functional Motor gives 50 Volts on white wire? Motor or pump seized? Check boiler controls & supply No Lockout after 12 sec purge? Ignition spark proved? NO Lockout within 1 second? Yes No Yes Eectrodes & leads OK? No No Yes Yes Pipe to nozzle holder OK? Replace nozzle Replace control box Yes Replace control box Replace electrodes/ leads Yes L & N to control box? No Burner motor runs? Boiler not operating with a heating / hot water demand FAULT FINDING & DIAGRAMS Yes Yes No No Replace control box Reseal BF Boiler or flue blocked Reset combustion head These fault finding charts are provided to assist competent and suitably qualified engineers to locate and rectify faults. Whilst every effort has been taken to ensure the information given is correct and complete we cannot guarantee that every eventuality has been covered. Worcester, Bosch Group cannot be held responsible for costs incurred by persons not deemed to be competent. FAULT FINDING LOGIC FOR 535 SE/LD RDB CONTROL BOX MODE SWITCH SERVICE CONNECTION L N MAINS CONNECTION INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 106 252b (07/06 X1 (PIN 3) ELECTRICAL SCHEMATIC C1 X4 (PIN 3) brown X2 (FS) N N DHW CH LINK (REMOVE) N ROOM THERMOSTAT X2 (LS) X2 (NS) X2 (LR) 3 2 1 4 N RELAY 1 grey X8 (PIN 2) 3 2 white X10 (PIN 1) 1 3 4 blue X6 (PIN 4) WATER FLOW SWITCH brown X6 (PIN 2) grey R1 C1 N X13 (PIN 5) RELAY 4 X13 (PIN 2) 4 4 2 X8 (PIN 6) X7 (PIN 4) 2 4 6 BURNER MANUAL RESET FLUE OVERHEAT THERMOSTAT MANUAL RESET BOILER OVERHEAT THERMOSTAT AUTO RESET HIGH LIMIT THERMOSTAT CENTRAL HEATING CONTROL THERMOSTAT PLUG IN CONNECTOR red grey white N MOTORISED DIVERTER VALVE X8 (PIN 4) PUMP LOCKOUT RESET SWITCH brown red red NC red orange (C) (C) 3 grey NO orange 3 pink 2 4 NC X13 (PIN 3) 2 1 yellow X13 (PIN 1) N brown X7 (PIN 3) brown X7 (PIN 1) X8 (PIN 3) NO white N X11 (PIN 3) X12 (PIN 3) LOCKOUT INDICATOR X12 (PIN 4) R1 X3 (PIN 3 (L)) N RELAY 2 3 4 1 X11 (PIN 2) DHW CONTROL RELAY THERMOSTAT 3 N white X10 (PIN 3) DIVERTER END SWITCH orange X8 (PIN 5) LIVE SUPPLY FOR ALTERNATIVE DIVERTER VALVE X8 (PIN 1) X3 (PIN 3) X4 (PIN 2) white X4 (PIN 1) grey PROGRAMMER X2 (FR) X2 (FR) FROST THERMOSTATS X9 (PIN 2) BOILER MODE INDICATOR FAULT FINDING & DIAGRAMS FUSE F1 3.15A FAST CERAMIC X1 (PIN 1) X9 (PIN 1) X1 (PIN 6) X1 (PIN 5) ELECTRICAL SCHEMATIC 48 OIL BOILER COMBUSTION RECORD BOILER MODEL COMMISSIONING ENGINEER SERIAL No. COMBUSTION CHECKS COMPANY NAME: PUMP PRESSURE (PSI): ADDRESS: CO2 %: SMOKE READING: ENGINEERS NAME: SIGNATURE: F.G.T°C: FLUE PRESSURE: DATE: BURNER MODEL: FOR ALL BOILERS CONFIRM THE FOLLOWING THE CONDENSATE DRAIN HAS BEEN INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS YES OIL TYPE USED IS KEROSENE YES THE SYSTEM HAS BEEN FLUSHED IN ACCORDANCE WITH THE INSTRUCTIONS? YES THE SYSTEM CLEANER USED: THE INHIBITOR USED: SERVICE INTERVAL RECORD It is recommended that the heating system is serviced regularly and that you complete the appropriate Service Interval Record Overleaf. Service Provider. Before completing the appropriate Service Interval Record overleaf, please ensure you have carried out the service as described in this manual. Always use Worcester, Bosch Group specified spare parts when replacing all controls. 49 SERVICE 1 DATE SERVICE 2 DATE ENGINEER NAME COMPANY NAME TEL No. OFTEC REG No. PUMP PRESSURE: NOZZLE CHANGED? F.G.T. °C COMMENTS ENGINEER NAME COMPANY NAME TEL No. OFTEC REG No. PUMP PRESSURE: NOZZLE CHANGED? F.G.T. °C COMMENTS psi CO2%: YES NO FLUE PRESSURE: SIGNATURE SIGNATURE SERVICE 3 DATE SERVICE 4 DATE ENGINEER NAME COMPANY NAME TEL No. OFTEC REG No. PUMP PRESSURE: NOZZLE CHANGED? F.G.T. °C COMMENTS ENGINEER NAME COMPANY NAME TEL No. OFTEC REG No. PUMP PRESSURE: NOZZLE CHANGED? F.G.T. °C COMMENTS psi CO2%: YES NO FLUE PRESSURE: SIGNATURE SIGNATURE SERVICE 5 DATE SERVICE 6 DATE ENGINEER NAME COMPANY NAME TEL No. OFTEC REG No. PUMP PRESSURE: NOZZLE CHANGED? F.G.T. °C COMMENTS ENGINEER NAME COMPANY NAME TEL No. OFTEC REG No. PUMP PRESSURE: NOZZLE CHANGED? F.G.T. °C COMMENTS psi CO2%: YES NO FLUE PRESSURE: SIGNATURE SIGNATURE SERVICE 7 DATE SERVICE 8 DATE ENGINEER NAME COMPANY NAME TEL No. OFTEC REG No. PUMP PRESSURE: NOZZLE CHANGED? F.G.T. °C COMMENTS ENGINEER NAME COMPANY NAME TEL No. OFTEC REG No. PUMP PRESSURE: NOZZLE CHANGED? F.G.T. °C COMMENTS psi CO2%: YES NO FLUE PRESSURE: SIGNATURE SIGNATURE SERVICE 9 DATE SERVICE 10 DATE ENGINEER NAME COMPANY NAME TEL No. OFTEC REG No. PUMP PRESSURE: NOZZLE CHANGED? F.G.T. °C COMMENTS ENGINEER NAME COMPANY NAME TEL No. OFTEC REG No. PUMP PRESSURE: NOZZLE CHANGED? F.G.T. °C COMMENTS SIGNATURE psi CO2%: YES NO FLUE PRESSURE: SIGNATURE psi CO2%: YES NO FLUE PRESSURE: psi CO2%: YES NO FLUE PRESSURE: psi CO2%: YES NO FLUE PRESSURE: psi CO2%: YES NO FLUE PRESSURE: psi CO2%: YES NO FLUE PRESSURE: 50 In the unlikely event the boiler does not give complete satisfaction, before calling for a service engineer, the installer should check the following:General checks 1. Is the mode switch in boiler mode (indicator on)? 2. Is there 230V across the boiler live and neutral terminals? 3. Is the polarity correct? (230V across live and earth, 0V across neutral and earth) 4. Is the air bled from the primary system? 5. Is the air bled from the oil supply? 6. Is the flue sized and routed correctly? Boiler runs straight to lockout 1. Has the oil line been purged of air? 2. Where an air eliminator is used in conjunction with a top feed oil tank the non-return valve, (if fitted), should be removed from the oil dip pipe. Boiler locks out at the start of a demand (Heating off overnight for example) 1. If an air eliminator is being used, check that there are no leaks that allow air to be pulled into the oil supply. 2. If a two pipe oil supply is a being used, has a non-return valve been fitted to the inlet pipe? Refer to the instructions for guidelines. No domestic hot water (external programmer) 1. Is the mains water in connected to the 15mm isolation valve? 2. Is there a domestic hot water demand from the programmer and has the tank reached temperature? 3. Is there 230V on pin 2 of terminal block X4? 4. Remove the external wiring from terminal block X4 and fit a link across 1 and 2, if the domestic hot water now operates there is a problem with the external programmer and/or its wiring. No central heating (external programmer) 1. Are both programmer and room thermostat on demand for central heating? 2. Is the room thermostat wired correctly? 3. Refit the link across pins LS and LR on terminal X2, if the central heating now operates correctly the room thermostat and/or its wiring are faulty. 4. Is there 230V on pin 1 of terminal block X4? 5. Remove the external wiring to terminal block X4 and fit a link across pins 1 and 3 on terminal X4, if the central heating now operates correctly the room programmer and/or its wiring are faulty. CONTACT INFORMATION WORCESTER, BOSCH GROUP: TECHNICAL: 08705 266241 SERVICE: SPARES: 08457 256206 01905 752571 LITERATURE: TRAINING: 01905 752556 01905 752526 SALES: WEBSITE: 01905 752640 www.worcester-bosch.co.uk WATER TREATMENT: FERNOX 01799 550811 www.fernox.com SENTINEL 0151 420 9595 www.betzdearborn.com/sentinel FLUE TERMINAL GUARD: PART No. 7 716 190 050 UNDER NO CIRCUMSTANCES MUST AN APPLIANCE BE LEFT TO OPERATE WITH ANY CONTROL LINKED OUT OR OVER RIDDEN. EXCELLENCE COMES AS STANDARD Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW. Tel. 01905 754624 Fax. 01905 754619 Worcester, Bosch Group is a trading name of BBT Thermotechnology UK Ltd. www.worcester-bosch.co.uk 8 716 113 389b (09/07)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Page Count : 52 XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:f4ec4457-14db-4c58-ad83-22b501aa27dc Producer : PSNormalizer.framework Modify Date : 2008:05:20 12:14:09+01:00 Create Date : 2007:10:03 09:42:33+01:00 Metadata Date : 2008:05:20 12:14:09+01:00 Document ID : uuid:5ccdce5a-718d-11dc-92a0-000a95bed70c Format : application/pdfEXIF Metadata provided by EXIF.tools