Boston Life Labs BPW24 Wrist Blood Pressure User Manual BLL BPW2 4 Wrist Blood Pressure Monitor Use manual

Boston Life Labs LLC. Wrist Blood Pressure BLL BPW2 4 Wrist Blood Pressure Monitor Use manual

User manual

     Wireless Wrist Blood Pressure Monitor BPW2.4         Boston Life Labs LLC.
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor   II                     Instructions to User Dear Users,   Thank you  for  purchasing our product.  Please  read the manual  carefully  before  using  this  device.  Failure  to follow  these  instructions  may  cause  measuring abnormality or equipment damage. The  Manual  is  published  in  English  and  Boston  Life Labs LLC. has the ultimate right to explain the Manual. No part of this manual may be photocopied, reproduced or  translated  into  another  language  without  the  prior written  consent.  Boston  Life  Labs  LLC.  reserves  the right to improve and amend it at any time without prior notice. Version of this manual: Ver 1.0 All rights reserved.
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor   III                     Notes:  The contents contained in this manual are subject to change without notice.  Information furnished by our company is believed to be accurate and reliable. However, no responsibility is assumed by us for its use, or any infringements of patents or other rights of third parties that may result from its use. Instructions for Safe Operations  Read  all  information in the instruction  manual and  any  other  literature  included  in  the  box before using the unit.  Contact your physician for specific information about  your  blood  pressure.  Follow  the instructions of your healthcare provider.  Operate the unit only as intended. Don’t use for any other purpose.  The  unit  is  indented  to  use  in  measuring  the blood pressure and pulse rate for adult only, not recommended for neonatal baby.  Do not use a cellular near the unit. It may result in operational failure.  Please avoid using in high radiant area in order to make your measurement data correctly.
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor   IV                      Necessary maintenance must be performed only by qualified service  technicians.  Users  are  not permitted to maintain it by themselves. Cautions  Explosive hazard—DO NOT use the equipment in  environment  with  inflammable  gas  such  as some ignitable anesthetic agents. Warnings  The local law must be followed when disposing of the device. Attentions ֠ Keep  the  device  away  from  dust,  vibration, corrosive  substances, explosive materials,  high temperature and moisture. ֠ The device  should be  kept  out  of  the  reach  of children. ֠ If the  equipment gets wet, please stop using it and  do  not  resume  operation  until  it  is  dry. When it is carried from a cold environment to a warm  and  humid  environment,  please  do  not use it immediately. ֠ DO NOT operate the button on the front panel with sharp materials.
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor   V                     Table of Contents 1 OVERVIEW ......................................................... 1 1.1 APPEARANCE ................................................... 1 1.2 FEATURES ........................................................ 2 1.3 NAME AND MODEL .......................................... 2 1.4 APPLICATIONS AND SCOPE .............................. 2 2 BATTERY INSTALLATION .............................. 3 3 WIRELESS FUNCTION ..................................... 4 3.1 ENABLE/DISABLE BLUETOOTH ....................... 4 3.2 DATA MANAGEMENT ....................................... 5 4 OPERATION ....................................................... 6 5 MAKE A MEASUREMENT ............................... 8 6 EXCEPTIONAL SITUATIONS ........................ 10 7 TECHNICAL SPECIFICATIONS.................... 12 8 REPAIR AND MAINTENANCE ...................... 13 8.1 MAINTENANCE .............................................. 13 8.2 CLEANING AND DISINFECTING INSTRUCTION14 9 COMMON KNOWLEDGE .............................. 15
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor   VI                     9.1 BLOOD CIRCULATION .................................... 15 9.2 CLASSIFICATION OF BLOOD PRESSURE ......... 15
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -1- 1 Overview 1.1 Appearance               Body & Cuff Display Start/Stop Button Wrist Cuff Display Systolic Blood Pressure Diastolic Blood Pressure Unit Indication Pulse Display Low Battery   Symbol Inflation/Deflation Symbol or WHO IndicationHeartbeat SymbolWirelessSymbolPower 2 AAA Alkaline Batteries
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -2- 1.2 Features The  Wireless  Wrist  Blood  Pressure  Monitor  can  be used to measure blood pressure Systolic, Diastolic and pulse rate value. The unit uses the oscillometric method of  blood  pressure  measurement.  It  means  the  unit detects  the  movement  of  your  blood  through  your brachial artery, and converts your blood pressure into a digital  reading.  The  unit  is  simple  to  use  because  a stethoscope is not needed while using an oscillometric monitor.  With  MWI  (measurement  while  inflating) technology;  Automatically inflate and deflate;  Automatic send measurement result wirelessly; 1.3 Name and Model     Name: Wireless Wrist Blood Pressure Monitor     Model: BPW2.4 1.4 Applications and Scope BPW2.4  Wireless  Wrist  Blood  Pressure  Monitor  is intended to be used by adults at home or medical center to measure Blood Pressure Systolic, Diastolic and pulse rate.
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -3- 2 Battery Installation        Figure 3 Battery Installation 1. Refer to Figure 3, insert two AAA size batteries into the  battery  compartment  properly  in  the  right direction.   2. Replace the cover.    Please take care when you insert the batteries, or the improper insertion may make the device not work.  User two identical 1.5V alkaline batteries type AAA LR03.  Replace  all  of  the  batteries  if  the  symbol  of  low battery appears on the display.
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -4-  Never  leave  any  low  battery  in  the  battery compartment since they may leak and cause damage to the unit. 3 Wireless Function 3.1 Enable/Disable Bluetooth The  state  of  the  Bluetooth  will  appear  after  longtime pressing the Start/Stop button. Then press the Start/Stop button to change the state of the Bluetooth to ON or OFF. Finally,  longtime  press  the  Start/Button  to  exit  the menu.    When Bluetooth is ON, the segments are displayed on the bottom left corner of the screen.
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -5- 3.2 Data Management When Bluetooth is ON and after a measurement result is made, the Bluetooth part will be powered on and try to connect to the peer device if there is any, otherwise it will enter into discoverable/connectable mode, waiting the SPP connection from any peer device for about 60 seconds. If the device fails to connect the peer device, it will also enter into the discoverable/connectable mode for about 60 seconds.   If  the  timeout  comes,  the  device  will  power  off  the Bluetooth part. In  the  discoverable/connectable  mode,  if  the  device receives  a  pairing/connecting  request  from  a  peer device, the pin code “6666” should/may be used. After the Bluetooth SPP is established, the device will send the measurement data to the peer device, then the SPP connection is disconnected and the Bluetooth part is powered off.     Bluetooth is ON  Bluetooth is connecting  Bluetooth is connected
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -6- 4 Operation 1. Remove all clothes from your arm allowing the cuff to fit directly on the skin.       2. Wrap the cuff tightly around your wrist by using the Velcro strip.     3. Turn  your  palm  upward;  stretch  your  fingers  and wrist naturally. 4. Use  a  soft  stuff  below  the  BP  monitor  to  support your arm as the figure shown below. 5. Keep your wrist at the same level of your heart. 6. Sit upright in a chair, and take about 10 deep breaths to  relax  your  entire body,  especially  between your
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -7- elbow and fingers. Then turn on the unit to start the measure.        Fingers’ pose:                 Do not touch Not good Good Not good
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -8- Wrist’ pose:         5 Make a Measurement 1. Press the Start/Stop button. All  Display  symbols  appear  on  the  screen.  The  cuff starts to inflate automatically.    2. Measurement starts while inflating. The heartbeat symbol flashes once a pulse is detected. Not good Not good Good All symbols   display  Deflating automatically  Start to inflate
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -9-   3. The blood pressure and pulse rate are displayed when the measurement completed. The  cuff  is  deflated  automatically.  If the  Bluetooth  is enabled,  the  device  automatically  tries  to  send  the measurement results.     4.  Press  the  Start/Stop  button  to  start  a  new measurement or longtime press the Start/Stop button to turn off the unit.   The  unit  will  automatically  turn off  after two minutes  if  you  have forgotten to turn it off. Please  rest  for  at  least  3  minutes before taking the next measurement.  “mmHg” display Start to inflate  Inflating Heartbeat  appears  Continue  Inflating  To a fit  pressure
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -10- 6 Exceptional Situations Error Indicators: The following symbol will appear on the display when measuring abnormal. Symbol  Cause  Correction  The  course  of inflation appears error. Wrap  the  cuff correctly and tightly. Inflate  over  again after ensuring. When measurement fails. Do  not  Move  your arm  and  body  and keep quiet. Measure  over  again according  to  correct way.   When  the battery  power is too low. Replace  all  of  the worn  batteries  with two new ones.
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -11- Error Indicators: Problem  Causes and Solutions No power.  Replace  all  of  the  worn batteries with two new ones. No display appears on  the  display screen. Check  the  battery  installation for  proper  placement  of  the batteries polarities. Measurements values  appear  too high or too low. Blood  pressure  varies constantly.  Many  factors including  stress,  time  of  day, how  you  wrap  the  cuff,  may affect  your  blood  pressure. Review  the  sections  “Proper Way  of  Measurement”  and “Take a Measurement”.
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -12- 7 Technical Specifications A. Display mode:LCD Display B. Power supply requirement:   1.5V (AAA size) alkaline battery × 2   Supply voltage: 3VDC   Operating current: ≤60mA C. Environment requirement           Operating Temperature: 10°C ~40°C (50~104°F)     Operating Humidity:            15%~90% (Noncondensing)     Atmospheric pressure:        70kPa~106kPa D. Pressure Parameter Specifications Measuring range: 0 to 299 mmHg Accuracy: ±3mmHg % E. Pulse Rate Parameter Specifications     Measuring range: 40bpm~180bpm     Accuracy: ±5% of reading F. Gross Weight     110g (battery not included) G. Bluetooth Bluetooth® Class 2 v2.0, ~20m range in open area
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -13- 8 Repair and Maintenance 8.1 Maintenance In order  to  ensure the long service life of the  device, please pay attention to the use of maintenance. A.  Please  change  the  batteries  when  the  low-voltage indicator lightens. B. Please clean the surface of the device before using. Wipe  the device  with  alcohol first, and  then  let it dry in air or wipe it dry. C. Please take out the batteries if the device will not be used for 3 months or longer. Always replace all the batteries with new ones at the same time. D. Store the device in a clean and dry location. Do not subject the unit to extreme hot or cold temperature, humidity and direct sunlight. E. Do not clean the body and cuff with naphtha, thinner or gasoline etc. F. Do not wet the cuff or attempt to clean the cuff with water.   G. The best storage environment of the device is -20ºC to 60ºC  ambient temperature and 10~95% relative humidity.
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -14-   High-pressure sterilization cannot be used on the device.     Do not immerse the device in liquid.   It is recommended that the device should be kept in a dry environment. Humidity may reduce the life of the device, or even damage it. 8.2 Cleaning and Disinfecting Instruction A. Surface-clean sensor with a soft gauze by saturating with  a  solution such  as  75% isopropyl  alcohol,  if low-level disinfection is required, use a 1:10 bleach solution.   B. Then surface-clean with clean water and dry with a piece of cloth. Caution:  Do  not  sterilize  by  irradiation  steam,  or ethylene oxide. Do not use the sensor if it is damaged.
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -15- 9 Common Knowledge 9.1 Blood Circulation The blood pressure is responsible for supplying the body with oxygen. Blood pressure is the pressure exerted on the arteries. The systolic blood pressure (higher pressure or top value) represents the blood pressure produced by contraction of the heart muscle. The  diastolic  blood  pressure  (lower  pressure  or  lower value)  represents  the  blood  pressure  produced  by relaxation of the heart muscle.     9.2 Classification of Blood Pressure After each measurement is completed, the LCD display will  show  your  position  automatically  on  the  six segments of the bar indicator which corresponds to WHO Blood Pressure Indicator. Contraction of the heart muscle ↓  Extrude blood ↓  Pressure included to the blood vessel = Higher pressure  Relaxation of the heart muscle ↓  Blood return heart ↓  Pressure decreased to the blood vessel = Lower pressure  Systolic Blood Pressure  Diastolic Blood Pressure
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -16-      Note:  When  a  person’s  systolic  and  diastolic  pressures fall into different categories, the higher category should apply.
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -17- Appendix Key of Symbols Symbol  Description   With Type B applied part   Warning ─ See User Manual SYS  Blood Pressure Systolic DIA  Blood Pressure Diastolic PUL/min  Pulse rate (beats per minute)   Low battery voltage SN  Serial number  Separate collection for this device.
User Manual for PBW2.4 Wireless Wrist Blood Pressure Monitor -18-       Boston Life Labs LLC. Address: Cambridge Innovation Center One Broadway 14th   Cambridge, MA 02142, U.S.A. Tel: +1 (617) 440-4271 Email: info@bostonlifelabs.com Website: www.bostonlifelabs.com
FCC ID: YTK-BPW2.4  IMPORTANT REGULATORY INFORMATION  This device complies with Part 15 of the FCC Rules:  Operation is subject to the following two conditions: 1.  This device may not cause harmful interference and 2.  This device must accept any interference that is received, including any interference that may cause undesired operation.     WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipments.